首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents a comparative study of 222Rn emanation from the ore and backfill tailings in an underground uranium mine located at Jaduguda, India. The effects of surface area, porosity, 226Ra and moisture contents on 222Rn emanation rate were examined. The study revealed that the bulk porosity of backfill tailings is more than two orders of magnitude than that of the ore. The geometric mean radon emanation rates from the ore body and backfill tailings were found to be 10.01?×?10?3 and 1.03 Bq m?2 s?1, respectively. Significant positive linear correlations between 222Rn emanation rate and the 226Ra content of ore and tailings were observed. For normalised 226Ra content, the 222Rn emanation rate from tailings was found to be 283 times higher than the ore due to higher bulk porosity and surface area. The relative radon emanation from the tailings with moisture fraction of 0.14 was found to be 2.4 times higher than the oven-dried tailings. The study suggested that the mill tailings used as a backfill material significantly contributes to radon emanation as compared to the ore body itself and the 226Ra content and bulk porosity are the dominant factors for radon emanation into the mine atmosphere.  相似文献   

2.
Radon control systems were Installed and evaluated In fourteen homes In the Spokane River Valley/Rathdrum Prairie and In one home In Vancouver, Washington. Because of local soil conditions, subsurface ventilation (SSV) by pressurlzatlon was always more effective In these houses than SSV by depressurlzatlon In reducing Indoor radon levels to below guidelines. Basement overpressurlzatlon was successfully applied In five houses with airtight basements where practical-sized fans could develop an overpressure of 1 to 3 Pascals. Crawlspace ventilation was more effective than crawlspace Isolation in reducing radon entry from the crawlspace, but had to be used In conjunction with other mitigation techniques, since the houses also had basements. Indoor radon concentrations In two houses with alr-toalr heat exchangers (AAHX) were reduced to levels Inversely dependent on the new total ventilation rates and were lowered even further In one house where the air distribution system was modified. Sealing penetrations In the below-grade surfaces of substructures was relatively Ineffective In controlling radon. Operation of the radon control systems (except for the AAHX’s) made no measureable change in ventilation rates or Indoor concentrations of other measured pollutants. Installation costs by treated floor area ranged from approximately $4/m2 for sealing to $28/m2 for the AAHX’s. Based on the low electric rates for the region, annual operating costs for the active systems were estimated to be approximately $60 to $170.  相似文献   

3.
Thoron (220Rn), an isotope of the radon family, is produced in the earth’s crust at a rate comparable to that of common radon (222Rn). Thoron’s average activity concentration in soil gas and ground-level outside air is comparable to that of radon. Recent data from Europe and the United States indicate that in terms of the energy of the alpha particle decays of thoron’s progeny, its concentration in indoor air is significant, typically about half that due to radon progeny. This paper reviews current knowledge about thoron and its progeny in the outdoor and indoor environments and discusses issues involved in assessing whether or not it is a significant indoor pollutant.  相似文献   

4.
Burning natural gas in power plants may emit radon (222Rn) into the atmosphere. On the University Park campus of The Pennsylvania State University, atmospheric radon enhancements were measured and modeled in the vicinity of their two power plants. The three-part study first involved measuring ambient outdoor radon concentrations from August 2014 through January 2015 at four sites upwind and downwind of the power plants at distances ranging from 80 m to 310 m. For each plant, one site served as a background site, while three other sites measured radon concentration enhancements downwind. Second, the radon content of natural gas flowing into the power plant was measured, and third, a plume dispersion model was used to predict the radon concentrations downwind of the power plants. These predictions are compared to the measured downwind enhancements in radon to determine whether the observed radon concentration enhancements could be attributed to the power plants’ emissions. Atmospheric radon concentrations were consistently low as compared to the EPA action level of 148 Bq m?3, averaging 34.5 ± 2.7 Bq m?3 around the East Campus Steam Plant (ECSP) and 31.6 ± 2.7 Bq m?3 around the West Campus Steam Plant (WCSP). Significant concentrations of radon, ranging from 516 to 1,240 Bq m?3, were detected in the natural gas. The measured enhancements downwind of the ECSP averaged 6.2 Bq m?3 compared to modeled enhancements of 0.08 Bq m?3. Measured enhancements around the WCSP averaged ?0.2 Bq m?3 compared to the modeled enhancements of 0.05 Bq m?3, which were not significant compared to observational error. The comparison of the measured to modeled downwind radon enhancements shows no correlation over time. The measurements of radon levels in the vicinity of the power plants appear to be unaffected by the emissions from the power plants.

Implications: Radon measurements at sites surrounding power plants that utilize natural gas did not indicate that the radon concentrations originated from the plants’ emissions. There were elevated radon concentrations in the natural gas supply flowing into the power plants, but combustion dilution puts the concentration below EPA action levels coming out of the stack, so no hazardous levels were expected downwind. Power plant combustion of natural gas is not likely to pose a radiation health hazard unless very different gas radon concentrations or combustion dilution ratios are encountered.  相似文献   

5.
A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon (222Rn) concentrations above the U. S. EPA guideline of 148 Bq m?3 (4 pCi L?1). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m?3) from the highly permeable soils (geometric mean permeability of 5 × 10?11 m2) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m3h?1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operation, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon-laden substructure air throughout the rest of the building.  相似文献   

6.
Enhanced gamma (Δγ) ray dose rates due to 222Rn progeny wet deposited on the ground surface measured at six monitoring sites in Japan were statistically analyzed to investigate their temporal and spatial variations. Variations of Δγ ray dose rates indicated significant regional differences between the sites on the Sea of Japan coast and those located inland and on the Pacific coast in Japan. At the sites located on the Sea of Japan coast, significant seasonal variation was evident, with higher dose rates in autumn and winter, and lower dose rates in summer. In contrast, however, no significant seasonal variation was observed at the inland and Pacific coast sites in Japan. The variation of Δγ ray dose rates was characterized by three major factors: climatologically changed air masses arriving in Japan, variation of 222Rn and its progeny concentrations in the air column, and the regional characteristics of precipitation. It is evident that the contribution from local 222Rn to Δγ ray dose rates was smaller than those from continental 222Rn. Meso-scale atmospheric disturbance, however, was suggested as an important process for extremely high Δγ ray dose rates, possibly by the accumulation of additional local 222Rn with stronger convergence. It is therefore possible that the variation of Δγ ray dose rates reflects the chemical climatology of 222Rn and its progeny.  相似文献   

7.
Soil radon was measured from late October 2000 to January 2001 at three test sites on the campus of Hokkaido University in Sapporo, Japan. Factors affecting radon concentrations were investigated with relation to meteorological data, as well as soil 226Ra content, mineral composition, water content, and pH, Eh and conductivity. Soil radon varied with time and with sampling site appreciably, in a manner unaltered by the surface geology. However, the ratio of radon isotopes (220Rn/222Rn) in the soil was constant within each sampling site, regardless of varying concentration of these nuclides during the monitoring period. Snow covering on the soil surfaces may affect the 222Rn concentration.  相似文献   

8.
PM2.5 aerosols were sampled and atmospheric 222Rn (radon) was measured, at Hong Kong, China, over 3 years 2001–2003. The aerosol samples were analysed using accelerator-based Ion Beam Analysis (IBA) techniques to provide quantitative information on 21 of their major and minor elemental contributions. The radon concentration on aerosol sampling days was then used to classify the degree of land contact (high or low) experienced by air masses en route to the receptor site. It was found that elements known to originate from anthropogenic sources (e.g. Zn, K, Br, Pb and Black Carbon) were positively correlated with observed radon concentration. An eight-factor Positive Matrix Factorisation (PMF) analysis was performed on the data set, which resulted in elemental profiles (“fingerprints”) for eight potential sources and we identified source factors that were correlated with radon. The Potential Source Contribution Function technique was then used to identify the geographic regions most likely to have significantly contributed to the aerosol samples collected at the receptor site.  相似文献   

9.
In order to predict indoor radiation levels due to radon daughters at low building ventilation and air leakage rates, differential equations governing the decay and venting of radon (Rn-222) and its daughters were used. A computer program based on the equations was written to predict radon and daughter concentrations, total potential alpha energy concentration and equilibrium factor. The program can account for time dependence of ventilation and emanation rates and is readily used by building designers.

Sample calculations using the program showed that potential alpha energy levels in tightened buildings can commonly reach about 0.01 working level (WL), a level more than twice as high as concentrations currently found in most houses.  相似文献   

10.
In this paper, results on a PM10 daytime–nighttime measurement campaign carried out in Milan to study the evolution of PM10 concentration and composition in relation to atmospheric dispersion conditions are shown. To account for the evolution of atmospheric dispersion conditions, Radon hourly concentration measurements were performed. The significant correlation between PM10 and 222Rn daytime concentrations evidences the dominant role of atmospheric dispersion in determining the temporal variation of PM10 levels. Whenever 222Rn concentrations accumulate during the night (indicating the formation of nocturnal atmospheric stability conditions), PM10 concentrations are higher than those registered during the daytime before, despite a decrease in emissions from active sources. On the contrary, when 222Rn concentrations do not accumulate during night hours, PM10 levels are lower than those measured during the daytime before.As concerns the average elemental concentrations (in ng m−3), the nighttime–daytime variations are in the range −17% to +37%; during the night, soil-related elements (Al, Si, Ca, Ti) decrease while anthropogenic elements (Zn, Cu, Fe, Pb) increase.A case study concerning a ‘green’ Sunday (when traffic was forbidden from 8 a.m. to 8 p.m.) is also discussed. The difference of PM10 concentration and elemental composition registered during the ‘green’ Sunday daytime and the following nighttime, together with the information on atmospheric dilution power obtained by Radon measurements, allowed the characterisation of the traffic source elemental profile and increased the comprehension of the low effectiveness of some PM10 reduction strategies.  相似文献   

11.
The influence of 222Rn exhalation from walls and air exchange (low ventilation rates ν<0.3 h-1) upon its concentration in room air has been considered. It was found that the radon concentration reachs 84 Bq m-3 at exhalation and ventilation rates of 66 Bq hm-2 and 0.28 h-1, respectively. The radon concentration and the ultrafine fraction fp of potential α energy concentration as well as the equilibrium factor F of the short-lived radon progeny were also determined in three different completely closed rooms. An electroprecipitation method was applied for determining the 222Rn concentration while a single wire-screen technique was used for the determination of ultrafine radon progeny. During the measurements, the radon concentrations were varied between 33 and 134 with a mean value 89 Bq m-3. A mean ultrafine fraction (fp) of 0.16 was obtained at a mean aerosol particle concentration (Z) of 1700 cm-3 and a mean equilibrium factor (F) of 0.33. The obtained mean value of fp was found to be about five times higher than the value reported in the ICRP publication (fp=0.03). The attachment rate (X), the deposition rate (qf) and the deposition velocity (vfd) of the ultrafine radionuclide 218Po were calculated. A mean value of X was found to be 49 h-1 at a mean qf of 46 h-1 and a mean vfd of 4.6 m h-1. The attachment coefficient β of 218Po was found to vary between 0.016 and 0.047 with a mean value 0.028 cm3 h-1.  相似文献   

12.
13.
222Rn concentrations in the air in Nerja Cave (Spain) have been measured over 4 yr and at four sampling points. Concentrations average 168 Bq m-3 in the spring–summer when the temperature lapse rate provides a stable cave atmosphere. In the autumn–winter, the radon levels decrease to 48 Bq m-3. 222Rn flux has also been measured for soils in the cave, with an average value of 34 × 10-3 Bq m-2 s-1. The average natural flow rate in the spring–summer is about 0.70 m3 s-1 and the autumn–winter is approximately 3.6 m3 s-1 determined over 1992–1995. The radiation exposure levels for workers and tourists represent only a low percentage of the exposure guides for the general population.  相似文献   

14.
Radon control systems were installed and evaluated in fourteen homes in the Spokane River Valley/Rathdrum Prairie and in one home in Vancouver, Washington. Because of local soil conditions, subsurface ventilation (SSV) by pressurization was always more effective in these houses than SSV by depressurization in reducing indoor radon levels to below guidelines. Basement overpressurization was successfully applied in five houses with airtight basements where practical-sized fans could develop an overpressure of 1 to 3 Pascals. Crawlspace ventilation was more effective than crawlspace isolation in reducing radon entry from the crawlspace, but had to be used in conjunction with other mitigation techniques, since the houses also had basements. Indoor radon concentrations in two houses with air-to-air heat exchangers (AAHX) were reduced to levels inversely dependent on the new total ventilation rates and were lowered even further in one house where the air distribution system was modified. Sealing penetrations in the below-grade surfaces of substructures was relatively ineffective in controlling radon. Operation of the radon control systems (except for the AAHX's) made no measureable change in ventilation rates or indoor concentrations of other measured pollutants. Installation costs by treated floor area ranged from approximately $4/m2 for sealing to $28/m2 for the AAHX's. Based on the low electric rates for the region, annual operating costs for the active systems were estimated to be approximately $60 to $170.  相似文献   

15.
During a one-year period, from November 1998 upto October 1999, the atmospheric activity concentrations of the short-lived (222Rn)-progeny (218Po, 214Pb, 214Po) were measured every 4 h in the open air, using α-spectrometry. The concentration data of short-lived radon progeny together with meteorological variables (relative humidity, air temperature, and wind speed) were used for a comprehensive regression analysis of daily time variation of radioactivity in the air. The seasonal concentration pattern of all short-lived radon progeny shows the same trend for diurnal variation with higher values at night and early morning hours compared with lower values at noon and in afternoon. The activity concentrations were observed to be higher during the winter months (November–January) than in other seasons. The mean activity concentrations of 218Po, 214Pb and 214Po within the whole year were found to be 6.7±0.8, 4.9±0.5 and 4.4±0.3 Bq m−3, respectively.Also, within that time period, approximately 120 samples were analysed to determine the concentrations of the long-lived radon decay product 210Pb and the cosmogenic radionuclide 7Be using a single-filter technique. The course of 210Pb air concentration is characterized by higher values in autumn/winter season and lower values in spring/summer season. The seasonal concentration pattern of 7Be reaches regular maximum values in the spring to early summer months. The annual average concentration values of 210Pb and 7Be have been found to be 0.37±0.06 and 2.0±0.09 mBq m−3, respectively. A mean aerosol mass concentration of 36.6±6.2 μg m−3 was also determined during the measurements of the long-lived radionuclides. The majority of attached 210Pb and 7Be were observed at lower aerosol mass concentrations while small fractions of attached activities were found to be associated with the higher mass concentrations.  相似文献   

16.
Seasonal variation of indoor radon in dwellings of Malwa region, Punjab   总被引:1,自引:0,他引:1  
Indoor radon measurements in 105 dwellings belonging to 21 villages of Muktsar and Ferozepur districts of Malwa region, Punjab, have been carried out, using LR-115 type II cellulose nitrate films in the bare mode. The annual average indoor radon value in the study area varies from 76.25 to 145.50 Bq m−3, which is well within the recommended action level [ICRP, 1993. Protection against radon at home and work. Annals of ICRP, ICRP Publication, p. 65]. Seasonal variation of indoor radon shows high values in winter and low values in summer. The winter/summer ratio of radon concentration has been computed for all 105 dwellings. The winter/summer ratio of indoor radon ranges from 0.84 to 1.89 with an average of 1.46. The indoor radon values obtained in the present investigation are more than the world average of 40 Bq m−3  相似文献   

17.
This work shows how ambient radon concentrations measured at Cabauw station in central Netherlands are influenced by transport from different regions under typical transport conditions occurring during April and November, 2007 by means of atmospheric Lagrangian particle dispersion modelling in a receptor-oriented approach. Four specific regions have been isolated to assess their contribution to the modelled radon ambient concentrations at Cabauw, and two different radon flux assumptions. Westerly flows coming from the ocean are poor in radon and do not increase radon air concentrations unless there is some fetch over the British Isles. Continental transport, mainly from eastern and southern Europe, significantly increases radon background concentrations, reaching increments of 3 Bq m?3. A constant 0.66 atoms cm?2 s?1 radon flux over land and zero over water bodies is a good approximation for the source term in order to study regional contributions and modulation of the radon background.  相似文献   

18.
Diurnal radon concentrations were measured in a school and an office that exhibited high average annual radon concentrations from passive alpha track detector measurements. The diurnal measurements in both cases showed very high nighttime concentrations (3000–6000 Bq m−3) and low daytime concentrations under the action level of 200 Bq m−3 used in Norway. These results suggest that the only way to accurately assess radon exposure in day-use buildings is to include measurements of radon concentrations limited to the hours when the buildings are actually in use.  相似文献   

19.
Radon gas concentrations have been monitored as part of the operation of a tunnel (the Exploratory Studies Facility-ESF) at Yucca Mountain to ensure worker safety. The objective of this study was to examine the potential use of the radon data to estimate large-scale formation properties of fractured tuffs. This objective was examined by developing a numerical model, based upon the characteristics of the ESF and the Topopah Spring welded (TSw) tuff unit, capable of predicting radon concentrations for prescribed ventilation conditions. The model was used to address two specific issues. First, it was used to estimate the permeability and porosity of the fractures in the TSw at the length scale of the ESF and extending tens of meters into the TSw, which surrounds the ESF. Second, the model was used to understand the mechanism leading to radon concentrations exceeding a specified level within the ESF. The mechanism controlling radon concentrations in the ESF is a function of atmospheric barometric fluctuations being propagated down the ESF along with ventilated air flow and the slight suction induced by the ventilation exhaust fans at the South Portal of the ESF. These pressure fluctuations are dampened in the TSw fracture continuum according to its permeability and porosity. Consequently, as the barometric pressure in the ESF drops rapidly, formation gases from the TSw are pulled into the ESF, resulting in an increase in radon concentrations. Model calibration to both radon concentrations measured in the ESF and gas-phase pressure fluctuations in the TSw yielded concurrent estimates of TSw fracture permeability and porosity of 1 x 10(-11) m2 and 0.00034, respectively. The calibrated model was then used as a design tool to predict the effect of adjusting the current ventilation-system operation strategy for reducing the probability of radon gas concentrations exceeding a specified level.  相似文献   

20.
Combining a computational fluid dynamics (CFD) model and a multi-zonal model, a study was carried out on radon entry through the complex substructure of a house with a cellar. The uniqueness of the radon entry problem in this type of house was due to the involvement of two radon entry routes to two chambers: the cellar and the living area of the house. Soil gas carrying radon was driven through the two routes by two coupled disturbance pressures in the chambers. The effects of temperature differences were considered as another driving force for the radon entry. Examined in this study were the effects of the geometry of the substructure, air permeability of the soil, air-tightness of the cellar shell, and cellar ventilation on radon entry to both the cellar and the living area. The ground floor covering on top of the soil outside a cellar wall increased radon entry through this wall by about 68%, as radon built up to a very high level under the covering. The effect of cellar ventilation was found as follows: the cellar ventilation created a layer of airflow in the soil under the ground floor; the flow passed over a crack in the ground floor, the entry route to the living area, diluting the radon in the area. Hence, the soil gas entering the living area carried less radon. Cellar ventilation seems more effective in reducing radon entry to the living area in a more permeable soil and leaky cellar shell; a moderate cellar ventilation condition achieved 77% reduction in radon entry to the area. When permeability of these two materials was lower and soil radon content remained the same, the chances of radon entry was also lower; hence, the indoor radon level was lower and no radon control was needed. When such soil contains high radon concentration, other mitigation measures must be sought.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号