首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An analysis of biomedical waste incineration.   总被引:2,自引:0,他引:2  
The California Air Resources Board (ARB) completed a series of source tests of eight operating biomedical waste incinerators (BMWI) under conditions of typical operation. The emissions of certain metals, and chlorinated dioxins and furans in the flue gases of BMWI are relatively high in comparison to emissions from other combustion sources, such as hazardous waste or municipal waste incinerators of modern design. This study reports on an analysis of the status of the existing regulatory framework and the California data base. Clarification of definitional issues at the federal level is needed to effectively treat BMWI management issues. Although few relationships among combustion parameters and emissions were uncovered, patterns of emissions were evident, suggesting commonality and relationships among the waste stream constituents and emissions. Potential implications for future research, operation of BMWI, controls and source reduction and waste segregation strategies are also discussed.  相似文献   

2.
The California Air Resources Board (ARB) completed a series of source tests of eight operating biomedical waste incinerators (BMWI) under conditions of typical operation. The emissions of certain metals, and chlorinated dioxins and furans in the flue gases of BMWI are relatively high in comparison to emissions from other combustion sources, such as hazardous waste or municipal waste incinerators of modern design. This study reports on an analysis of the status of the existing regulatory framework and the California data base. Clarification of definitional issues at the federal level is needed to effectively treat BMWI management issues. Although few relationships among combustion parameters and emissions were uncovered, patterns of emissions were evident, suggesting commonality and relationships among the waste stream constituents and emissions. Potential implications for future research, operation of BMWI, controls and source reduction and waste segregation strategies are also discussed.  相似文献   

3.
The emission abatement of polychlorinated dioxins and furans (PCDD/F) Issued from municipal solid waste incineration is growing in importance because of more stringent emission standards and general concern about their toxic characteristics. These substances cannot be separated by conventional gas cleanup processes but are successfully removed through adsorption onto carbonaceous materials. The simplest technique is the entrained-phase injection of pulverized adsorbents in the flue gas, followed by fabric filter separation. The various related techniques are briefly reviewed here. Operating conditions and results obtained from Flemish MSWIs are given. The results illustrate the excellent overall removal efficiency. Furans are adsorbed to a slightly higher extent than dioxins. PCDD/F removal by carbonaceous adsorbents is thereafter modeled from first principles for the contribution of both entrained-phase (eta1) and cake filtration (eta2) to the overall efficiency (etaT). Application of the model equations and comparison of measured and predicted overall efficiencies for the Flemish municipal solid waste incinerators (MSWIs) demonstrate that the approach is meaningful and that the dominant parameters are the operating temperature, the dosage and activity of adsorbent, and the fraction of adsorbent in the filter cake. The model equations enable the MSWI operators to predict the adsorption efficiencies for any combination of operating parameters and to assess the sensitivity of the process to varying operating conditions.  相似文献   

4.
Emissions of dioxins are mainly from incinerators, domestic and industrial coal combustion, and traffic. However, the major public concern and research effort are associated with the emissions of organic micropollutants from waste incinerators. This paper gives a brief overview of the more recent research and development for the removal of dioxins and heavy metals from flue-gas streams. Special attention is devoted to the origin and control of emissions from incinerators. It appears that flue-gas cleaning systems in modern incinerators are very reliable in removing almost all polluting emissions from flue-gas streams. However, the fly ash residues generated pose a significant disposal problem, as they are enriched with heavy metals and organic micropollutants.  相似文献   

5.
Dioxin, furan and combustion gas data from test programs conducted at the Pitts field, Prince Edward Island, and Peekskill municipal solid waste incinerators were compared to identify similar and discrepant results. Dioxin and furan concentrations sampled upstream of air pollution control devices are related to a variety of combustion gas variables monitored in the high temperature zones of the incinerators. The effects of temperature, excess oxygen, carbon monoxide, hydrochloric acid gas, flue gas moisture, particulate loading and refuse moisture and PVC content are discussed. Conclusions are made and future research needs are discussed.  相似文献   

6.
Abstract

The emission abatement of polychlorinated dioxins and furans (PCDD/F) issued from municipal solid waste incineration is growing in importance because of more stringent emission standards and general concern about their toxic characteristics. These substances cannot be separated by conventional gas cleanup processes but are successfully removed through adsorption onto carbonaceous materials. The simplest technique is the entrained-phase injection of pulverized adsorbents in the flue gas, followed by fabric filter separation. The various related techniques are briefly reviewed here. Operating conditions and results obtained from Flemish MSWIs are given. The results illustrate the excellent overall removal efficiency. Furans are adsorbed to a slightly higher extent than dioxins.

PCDD/F removal by carbonaceous adsorbents is thereafter modeled from first principles for the contribution of both entrained-phase (η1) and cake filtration (η2) to the overall efficiency (ηT). Application of the model equations and comparison of measured and predicted overall efficiencies for the Flemish municipal solid waste incinerators (MSWIs) demonstrate that the approach is meaningful and that the dominant parameters are the operating temperature, the dosage and activity of adsorbent, and the fraction of adsorbent in the filter cake. The model equations enable the MSWI operators to predict the adsorption efficiencies for any combination of operating parameters and to assess the sensitivity of the process to varying operating conditions.  相似文献   

7.
The European Economic Community (EEC) has proposed strict limits on emissions of dioxins and furans from hazardous waste incinerators. The proposed limit is 0.1 ng/Nm3, expressed as the 2,3,7,8 TCDD toxic equivalent of 17 specific dioxin and furan congeners. These limits will potentially redefine technology selection and design for combustion, energy recovery, and air pollution control. The EPA has a different approach for controlling emissions of products of incomplete combustion (PICs) and reformation products such as dioxins and furans. Rather than limiting these contaminants individually and quantitatively, EPA proposes controlling them by assuring good combustion as measured by stack emissions of carbon monoxide (CO) and total hydrocarbons (THC).

Dioxins and furans are combustion by-products and emission control relies mainly on control of the combustion process. These compounds can also be reformed from certain precursor compounds and elements in lower temperature regions of the system downstream of the combustion process. Air pollution control technologies have demonstrated the ability to remove dioxins and furans as contaminants on fine particulate.

This paper will discuss the two regulatory approaches, the mechanisms for the formation and reformation of dioxins and furans, and the technologies available to control emissions.  相似文献   

8.
ABSTRACT

This study investigated medical waste practices used by hospitals in Oregon, Washington, and Idaho, which includes the majority of hospitals in the U.S. Environmental Protection Agency's (EPA) Region 10. During the fall of 1993, 225 hospitals were surveyed with a response rate of 72.5%. The results reported here focus on infectious waste segregation practices, medical waste treatment and disposal practices, and the operating status of hospital incinerators in these three states. Hospitals were provided a definition of medical waste in the survey, but were queried about how they define infectious waste. The results implied that there was no consensus about which agency or organization's definition of infectious waste should be used in their waste management programs. Confusion around the definition of infectious waste may also have contributed to the finding that almost half of the hospitals are not segregating infectious waste from other medical waste. The most frequently used practice of treating and disposing of medical waste was the use of private haulers that transport medical waste to treatment facilities (61.5%). The next most frequently reported techniques were pouring into municipal sewage (46.6%), depositing in landfills (41.6%), and autoclaving (32.3%). Other methods adopted by hospitals included Electro-Thermal-Deac-tivation (ETD), hydropulping, microwaving, and grinding before pouring into the municipal sewer. Hospitals were asked to identify all methods they used in the treatment and disposal of medical waste. Percentages, therefore, add up to greater than 100% because the majority chose more than one method. Hospitals in Oregon and Washington used microwaving and ETD methods to treat medical waste, while those in Idaho did not. No hospitals in any of the states reported using irradiation as a treatment technique. Most hospitals in Oregon and Washington no longer operate their incinerators due to more stringent regulations regarding air pollution emissions. Hospitals in Idaho, however, were still operating incinerators in the absence of state regulations specific to these types of facilities.  相似文献   

9.
Dioxin concentrations from municipal waste incinerators in Japan and elsewhere often show low concentrations that comply with legal limits (in this paper, the term "dioxin" designates WHO-TEQ: PCDD/Fs+dioxin-like PCB). However, such data is usually generated under normal steady state operational conditions, and there has been little investigation of releases occurring during startup and shutdown. It is important, therefore, to ascertain quantitatively emissions in an unsteady state (startup and shutdown) in order to correctly evaluate the relationship between emissions from a facility and the surrounding environment. The present study aimed to examine dioxin emissions of a continuously operated incinerator at startup and shutdown, and estimating the time period of greatest emission, and the processes causing dioxin generation. The startup process was divided into five stages and the shutdown into two; at each stage, dioxins in the flue gas were measured at the boiler outlet and the stack. From the concentration of dioxins and the flue gas volume at each stage, the amount of dioxins at startup and shutdown were calculated, and these were compared with that under steady state conditions. Dioxin concentration at the stack under steady state conditions was a very low level, while those at startup and shutdown were higher. In the case where dioxin concentration under a steady state is a low level like in this study, it is indicated that the total annual dioxin emission from a facility could be attributed to the startup periods.  相似文献   

10.
Noma Y  Yamamoto T  Giraud R  Sakai S 《Chemosphere》2006,62(7):1183-1195
In the first known study to characterize the emissions of polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs) from the thermal treatment of wastes containing PCNs, the formation and decomposition behavior of these pollutants was investigated both at laboratory scale and at plant scale. Exhaust gas measurements from laboratory-scale combustion of rubber belts containing PCNs (FB belts) were used as the basis for calculations predicting that the incremental dioxin toxic equivalency (TEQ) emissions from municipal solid waste (MSW) incinerators would be less than 0.1 ng/m3 N. In order to directly examine co-incineration of FB belts with MSW and to address potential differences between the laboratory experiment and full-scale MSW incinerators, experiments were conducted using a larger scale thermal treatment test facility with sampling and analysis at several points in the thermal treatment process. Congener specific analysis of PCNs clearly showed that both destruction and synthesis simultaneously occurred during combustion in the kiln. Most of the PCNs were destroyed by secondary combustion, and almost all PCNs were removed after flue gas treatment. Almost all PCDDs/DFs were synthesized as by-products of kiln combustion, most of them were destroyed by the secondary combustion, and almost all dioxins (PCDDs/DFs and dl-PCBs) were removed after flue gas treatment. The TEQ emission levels were less than 0.1 ng/m3 N for all plant-scale tests, and differences in TEQ emission levels were very small. Adding wastes containing PCNs to MSW will not influence thermal treatment emissions to the environment from modern solid waste incinerators.  相似文献   

11.
BACKGROUND: To observe the relationship between the PCDD/F and Co-PCB levels in samples of human breast milk and nearby waste incinerators in Tokyo, Japan. METHODS: Breast milk was taken from 240 mothers residing in Tokyo, Japan to measure and analyze the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs; 14 congeners), polychlorinated dibenzofurans (PCDFs; 15 congeners), and coplanar polychlorinated biphenyls (Co-PCBs; 12 congeners) contained in the fat. Individual milk samples (about 50 ml) were obtained from the mothers 30 days after delivery, between the months of June and September in 1999 and 2000. A map of Tokyo was used to measure the distances between each mother's place of residence and the closest public and industrial waste incinerators. RESULTS: The distances to the nearest waste incinerators bore no apparent correlations with the congeners of PCDD/Fs and Co-PCBs. The distances were also uncorrelated with the mean toxic equivalent quantities (TEQs) of PCDD/Fs (the sum of PCDDs and PCDFs), Co-PCBs, and the total PCDD/Fs and Co-PCBs. CONCLUSIONS: Although waste incinerators were the largest source of dioxins in Japan at the time of the study, the dioxins levels of mother's milk bore no apparent relationships with the distances between the mothers' domiciles and the nearest waste incinerators. In this study, several meaningful factors were not taken into account, namely, the wind direction, the level of dioxin emitted from each incinerator, the level of environmental pollution of dioxins, and the average time the mothers stayed at home each day. A full understanding of these points awaits future studies.  相似文献   

12.
为实现二恶英快速检测,指导废物焚烧炉二恶英减排,通过检测生活垃圾焚烧炉烟气中氯苯和二恶英浓度,研究了三氯苯、四氯苯和二恶英之间的关联关系,并利用实验室自行研制的飞行时间质谱仪对烟气样品的三氯苯进行在线检测。结果表明,三氯苯与二恶英毒性当量(I-TEQ)之间存在良好关联性,相关系数(R2)可达到0.89。仪器检测信号强度与三氯苯浓度之间具有良好的线性关系,根据在线检测烟气样品中三氯苯的信号可得到三氯苯浓度,并根据关联模型计算得到二恶英毒性当量值I-TEQ,实现了对烟气样品中二恶英的快速间接测量。  相似文献   

13.
Nakao T  Aozasa O  Ohta S  Miyata H 《Chemosphere》2006,62(3):459-468
We investigated combustion in a small home waste incinerator and analyzed both flue gas and residual ash for formation of the dioxin-related compounds polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and coplanar polychlorinated biphenyls and their precursors polychlorinated benzenes, polychlorinated phenols, polychlorinated diphenyl ethers, and polychlorinated biphenyls. Particularly, we investigated the effect of the incinerated material's composition on both the congener ratios of released compounds and the total concentration of all congeners of each compound. Eight different samples were prepared for incineration with four samples consist entirely paper, dead leaves, natural wood, or building materials. The remaining four samples contained mostly paper, but also other components such as fiber, non-chlorine-containing plastics, chlorine-containing plastics, and copper electric wire. The presence of non-chlorine-containing plastic in combustion samples did not increase overall dioxin or dioxin-precursor emissions. In contrast, chlorine-containing plastic resulted in a several-fold increase in total polychlorinated dioxins released, in both flue gas and residual ash. Copper wire resulted in a further several-fold increase in total polychlorinated dioxins and dioxin precursors released, with one exception: the addition of chlorine-containing plastic resulted in a many-fold increase in polychlorinated biphenyls, but only a modest further increase ( approximately 52%) with the further addition of copper. Homologue ratios tended toward higher-chlorine compounds as chlorine-containing plastic and Cu were added, but the results were far from uniform. Our results show that toxic dioxin release from small home waste incinerators must be considered significant, especially if even small amounts of chlorine-containing plastics or copper are burned.  相似文献   

14.
Steps towards a European dioxin emission inventory   总被引:7,自引:0,他引:7  
Quass U  Fermann MW  Bröker G 《Chemosphere》2000,40(9-11):1125-1129
The results of a project aiming at collection and evaluation of information regarding the industrial and non-industrial emission sources for dioxins and furans (PCDD/PCDF) in 17 European Countries (EU 15, CH, N) are presented. An overview about national documents covering dioxin emission inventories for the period 1990-1995 is given. Some data on emissions associated with residual materials, waste and waste water are presented additionally. Based on the air emission data contained in these documents the most important emission sources were determined which are assumed to cover about 90% of the overall emissions. For the selected sources and for all 17 countries new estimates of the atmospheric PCDD/PCDF emissions were derived from average emission factors and statistical activity rates for the year 1994. As a result, on the European scale the largest annual PCDD/PCDF emission is assessed to be released from municipal waste incineration, quite closely followed by emissions from iron ore sintering. Considerable releases of dioxins and furans--based, however, on highly uncertain data--are further assessed for domestic burning, accidental fires and (former) use of contaminated wood preservatives (pentachlorophenol). A lower but still significant emission is further assigned to the sector of non-ferrous metal production; particular processes used in this branch proved to generate very high PCDD/PCDF flue gas concentrations.  相似文献   

15.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were monitored in stack gas and fly ash of various Korean incinerators and in air samples collected near the facilities. Concentrations of PCDD/Fs in emissions were investigated, and characteristic PCDD/F homologue patterns were classified using statistical analyses. The PCDD/F emission levels in stack gas and fly ash samples from small incinerators (SIs) were higher than those from municipal solid waste incinerators (MSWIs). The PCDD/F concentrations ranged between 0.38 and 1.16 pg I-TEQ/m3 (21.2-75.2 pg/m3) in ambient air samples. The lower-chlorinated furans were the dominant components in most of the stack gas and fly ash samples from SIs, although this was not the case for fly ash from MSWIs. This homologue pattern is consistent with other studies reporting a high fraction of lower-chlorinated furans in most environmental samples affected by incinerator emissions, and it can be used as an indicator to assess the impact of such facilities on the surrounding environment.  相似文献   

16.
Abstract

This study investigates the characteristics of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the ambient air of two municipal solid waste incinerators (MSWIs: GS and RW) and a coal-fired power plant (PW) in the Kaohsiung County (KC) area in Taiwan. The results show that the toxic equivalency (TEQ) concentration in the flue gas of GS and RW averaged 0.090 and 0.044 ng international toxic equivalents (I-TEQ)/N·m3, respectively. The TEQ concentration in the flue gas of PW averaged 0.050 ng I-TEQ/N·m3. All PCDD/Fs concentrations from the stack flue gas are lower than the Taiwan Environmental Protection Administration emission standard. Furthermore, the mean I-TEQ concentration in the ambient atmosphere ranged from approximately 0.019 to 0.165 pg I-TEQ/N·m3, much lower than the environmental quality standards for dioxins in Japan (0.6 pg TEQ/N·m3). This work classified all sampling sites into three clusters according to k-means cluster analysis. The result shows a probable direct correlation between the GS incinerator and site C. Although the concentration from the PW plant did not exceed the emission standard, it was much higher than that in Fernández-Martínez’s study. For proper environmental management of dioxins, establishing a complete emission inventory of PCDD/Fs is necessary. The government of Taiwan should particularly pay more attention to power plants to address the information shortage.  相似文献   

17.
Five fluidized bed incinerators combusting municipal solid waste were assessed for the impact of coplanar PCBs on total TEQ emission. In 17 stack measurements, the coplanar PCBs contributed on average less than 3% to total TEQ with a maximum contribution of 7.5% to total TEQ in one measurement. Differences in the design of the flue gas cooling section did not show an effect on the impact of coplanar PCBs on total TEQ. The effect of emission control devices on the impact of coplanar PCBs on the total TEQ was studied in more detail at one incinerator. The relative contribution of PCBs to total TEQ increased along the flue gas line. This was caused by a slightly higher removal efficiency for TEQ relevant PCDDs/PCDFs compared to coplanar PCBs by the bag filters and a higher destruction efficiency for PCDDs/PCDFs compared to PCBs by the SCR catalyst. Additionally, the removal efficiencies of the emission control devices (bag filters and catalyst) for other chlorinated aromatic compounds which have been proposed as TEQ indicator compounds (polychlorinated benzenes and polychlorinated phenols) were compared with those for PCDDs/PCDFs and coplanar PCBs. Removal efficiencies for polychlorinated benzenes or polychlorinated phenols considerably differed from those of PCDD/PCDF and coplanar PCBs. Implications for TEQ assessments using indicator compounds as proposed in the literature are discussed.  相似文献   

18.
During the last two years an extensive series of dioxin measurements has been conducted on Danish municipal and hospital solid waste incinerators. The study was directed toward finding the total annual dioxin emissions from MSWI in Denmark, now estimated to be 3 kg. of dioxines and furanes. This sum is equivalent to 50 g. of 2,3,7,8-TCDD according to the Nordic Equivalents. Measurements were carried out according to a statistical design following a plan of pre-randomized sampling. This procedure allowed causal interpretation of the correlations found between the dioxin emissions and certain operating parameters. The statistical model obtained describes the emissions by variations between incinerators, by variation in time, and by changes in the load, the excess air and the HCl concentration in the flue gas.  相似文献   

19.
Dry scrubbing of the flue gas from chemical waste incineration is becoming an increasingly viable alternative to wet scrubbing. This paper discusses the relative advantages and disadvantages of wet and dry scrubbing systems and compares the relative capital and operating costs. The design parameters of the dry scrubbing process are discussed, including reagent atomization, gas dispersion, gas temperatures, and particulate removal. The history of dry scrubbing process applications is discussed, including the successful European hazardous waste systems. Finally, a comparison is made among three very different hazardous waste incinerators in the U.S. that will utilize dry scrubbing systems.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号