首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Baghouse performance at utility coal-fired power plants is determined by baghouse design, operating procedures, and the characteristics of the ash that is collected as a dustcake on the fabric filter. The Electric Power Research Institute has conducted laboratory research to identify the fundamental variables that influence baghouse performance. A database was assembled including measured characteristics of coal and dustcake ash, and data describing operating parameters and performance of full-scale and pilotscale baghouses. Predictions of performance can be based on physical characteristics of the ash to be filtered (discussed in Part I of this article), as well as chemical characterizations of the ash, or empirical correlations with the alkali content of the source coal The effects of design and operational variables can be included in these predictions. Baghouse performance can be optimized by exercising proper operating practices and by selecting a filtering fabric and cleaning method matched to the cohesivity of the ash to be collected.  相似文献   

2.
Abstract

The cumulative years of service of baghouses in the electric utility industry have doubled since the last industrywide review of their operating performance. We have gathered information from all 102 operating baghouses to develop an updated record of how this technology continues to serve the electric utility industry. In general, baghouse performance has met or exceeded the expectations for controlling emissions. There are, however, wide ranges of pressure drop and bag life performance. Most operators report a long-term trend of increasing pressure drop. The life expectancy of filter bags averages 7.5 years, with more than 20% of the population achieving more than 10 years of bag life. Factors such as coal and ash properties certainly affect baghouse operation, but another reason for variations in bag life is the lack of an optimized protocol for controlling the long-term buildup of residual dustcake. We conclude that many baghouses could operate with lower pressure drop and longer bag life by optimizing the cleaning system. Dustcake weight or drag are better indicators of performance than pressure drop and should be used to develop an optimum baghouse operating protocol.  相似文献   

3.
The operating characteristics of a pilot baghouse and the filtering characteristics of fly ash filtered from the flue gas of a pulverized coal-fired power plant were studied by techniques developed in the engineering research laboratories of the National Center for Air Pollution Control in Cincinnati. The permeability of the dust cake varied with the operating conditions of the baghouse in a way that significantly affects the pressure drop and power requirements of the system.  相似文献   

4.
An experimental investigation on sulfur dioxide removal in a pilot-scale spray dryer from the flue gas generated by combustion of low-sulfur (S) heavy oil is reported. A limewater slurry was sprayed through an ultrasonic two-fluid atomizer in the spray-dry chamber, and the spent sorbent was collected downstream in a pulse-jet baghouse together with fly ash. Flue gas was sampled at different points to measure the desulfurization efficiency after both the spray-dry chamber and the baghouse. Parametric tests were performed to study the effect of the following variables: gas inlet temperature, difference between gas outlet temperature and adiabatic saturation temperature, lime-to-S ratio, and average size of lime particles in the slurry. Results indicated that spray drying is an effective technology for the desulfurization of low-S fuel oil flue gas, provided operating conditions are chosen carefully. In particular, the lowest gas inlet and outlet temperatures compatible with baghouse operation should be selected, as should a sufficiently high lime-to-S ratio. The attainment of a small lime particle size in the slurry is critical for obtaining a high desulfurization efficiency. A previously presented spray-dry flue gas desulfurization model was used to simulate the pilot-scale desulfurization tests, to check the ability of the model to predict the S capture data and its usefulness as a design tool, minimizing the need for pilot-scale experimentation. Comparison between model and experimental results was fairly good for the whole range of calcium/S ratios considered.  相似文献   

5.
The United Power Association’s dry FGD system at Stanton, North Dakota was the first utility-operated lime spray dryer to be put into service in the United States. At 60 MW in size, it utilizes a single spray dryer vessel with three rotary atomizers and a ten-compartment fabric filter. It is currently operating at better than expected efficiency and Is meeting state and federal air quality requirements. Start-up and operation have shown that certain areas of design and operating conditions are critical to reliable operation. Flue gas, slurry, and water distribution and mixing must be carefully controlled if reliable, long term operation is to be achieved. Likewise, water chemistry Is Important in the reagent preparation equipment. Start-up of the system was accomplished In a step-wise fashion to bring the baghouse on line first, followed by the spray dryer. The spray dryer was operated at gradually lower outlet temperatures until design conditions were met. Measures taken since start-up to ensure reliable operation, and operation over an eighteen month period are discussed. Both particulate and SO2 emission performance are evaluated.  相似文献   

6.
Electric utilities have made significant progress in recent years in designing and operating baghouses for collection of coal fly ash. As a result, early concerns with high operating and maintenance requirements and short bag lives are no longer an issue. With increasingly stringent air emissions regulations and imminent revision of the Clean Air Act, baghouses have become an attractive particulate collection option for utilities.

In order to keep its member utilities apprised of the latest design and operation and maintenance experience with baghouses, the Electric Power Research Institute has been conducting surveys of utility baghouse user experience. This paper presents results from the latest survey, conducted in 1989. A previous survey was conducted in 1985. The 1989 survey was conducted using questionnaires mailed to the utilities, telephone inquiries, and plant visits. This paper discusses the general trends observed in baghouse design, performance, operation and maintenance.  相似文献   

7.
Abstract

In recent years, the utility industry has turned to bag-houses as an alternative technology for particulate emission control from pulverized-coal–fired power plants. One of the more significant issues is to improve poor gas distribution that causes bag failures in baghouse operation. Bag failures during operation are almost impossible to prevent, but proper flow design can help in their prevention. This study investigated vertical velocity profiles below the bags in a baghouse (the hopper region) to determine whether flow could be improved with the installation of flow distributors in the hopper region. Three types of flow distributors were used to improve flow distribution and were compared with the original baghouse without flow distributors. Velocity profiles were measured by a hot-wire anemometer at an inlet velocity of 18 m/sec. Uniformity of flow distribution was calculated by the uniformity value U for the velocity profile of each flow distributor. Experimental results showed that the velocity profile of the empty configuration (without flow distributors) was poor because the uniformity value was 2.048. The uniformity values of type 1 (flow distributor with three vertical vanes), type 2 (flow distributor with one vertical and one inclined vane), and type 3 (flow distributor with two inclined vanes) configurations were reduced to 1.051, 0.617, and 0.526, respectively. These results indicate that the flow distributors designed in this study made significant improvements in the velocity profile of a baghouse, with the type 3 configuration having the best performance.  相似文献   

8.
Huang WJ  Tsai JL  Liao MH 《Chemosphere》2008,71(10):1860-1865
In this study, three municipal solid waste incinerator (MSWI) ash wastes-bottom ash, scrubber residue, and baghouse ash-were extracted using a toxicity characteristic leaching procedure (TCLP) extractant. These so-called final TCLP extracts were applied to African green monkey kidney cells (Vero), baby hamster kidney cells (BHK-21), and pig kidney cells (PK-15), multi-well absorption reader analysis was performed to test how the cytotoxicity of the incineration ashes would affect the digestive systems of animals. Ion-coupled plasma analyses indicated that the baghouse ash extract possessed the highest pH and heavy metal concentration, its cytotoxicity was also the highest. In contrast, the bottom ash and the scrubber residue exhibited very low cytotoxicities. The cytotoxicities of mixtures of baghouse ash and scrubber residue toward the three tested cell lines increased as the relative ratio of the baghouse ash increased, especially for the Vero cells. The slight cytotoxicity of the scrubber residue arose mainly from the presence of Cr species, whereas the high cytotoxicity of the baghouse ash resulted from its high content of heavy metals and alkali ions. In addition, it appears that the dissolved total organic carbon content of these ash wastes can reduce the cytotoxicity of ash wastes that collect in animal cells.  相似文献   

9.
In advanced electrostatic stimulation of fabric filtration (AESFF), a high voltage electrode is placed coaxially inside a filter bag to establish an electric field between the electrode and the bag surface. The electric field alters the dust deposition pattern within the bag, yielding a much lower pressure drop than that found in a conventional bag. Pilot plant results show that AESFF bags can operate with a rate of pressure loss that is 70 percent below that for conventional bags. The presence of the electric field also affects the aging characteristics of the AESFF bags. On the average, the AESFF bags had residual drags that were 10 percent below those of conventional bags. The results show that AESFF baghouses can yield the same pressure drop performance as conventional baghouses while operating at much higher air-to-cloth ratios. An economic analysis evaluated the capital, operating, and maintenance costs for electric utility plants ranging from 200 to 1,000 MW. For AESFF baghouses the capital cost was found to be 25 to 48 percent below that of a conventional baghouse. A lifetime cost analysis predicts a net present value for an AESFF baghouse that is 10 to 30 percent below that of a conventional baghouse.  相似文献   

10.
Polychlorinated dibenzodioxins/furans (PCDD/F) were formed in substantial quantities in a pilot-scale fluidized bed combustor burning salt-laden waste wood, a common fuel for Canadian coastal pulp and paper mills. Formation of PCDD/F increased with increasing chloride content in the feed, and appeared to correlate with the chlorine content in the fly ash. It took a very long time for the ash chlorine content to stabilize, suggesting that chlorine transferred slowly from the flue gas to the ash. The baghouse may contribute largely to formation of the PCDD/F, owing to its temperature range and the potentially long residence time for ash particles. Controlling the baghouse temperature to reduce the PCDD/F formation in the baghouse should be effective in reducing the total emission level. While sulphur addition was found to reduce the emission level by as much as 90%, the emission level was still above the regulated level for the mills burning salt-laden wood under the conditions of the present study. No relation between the emission level and CO concentration in the flue gas was observed.  相似文献   

11.
Abstract

In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 µm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38–99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1–1 µm. In this size range, ESP and baghouse collection efficiencies are 85.79–98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.  相似文献   

12.
An electrostatic precipitator preceded by a wet scrubber was tested at the Reftinskaya Power Station. The unit collects a high resistivity fly ash from the combustion of low sulfur Ekibastuz coal. The operating parameters of the precipitator were measured as well as the mass emissions and the in-situ electrical resistivity of the fly ash. Density, particle size distribution, electrical resistivity, and chemical composition were determined for collected samples of the fly ash. The fly ash was also characterized by x-ray diffraction and scanning electron microscopy. When a centrifugal wet wall scrubber was installed ahead of the electrostatic precipitator, the temperature of the flue gas entering the precipitator was decreased and the moisture content increased. The electrical resistivity of the fly ash was attenuated a decade, but not enough to overcome the adverse effects of back corona in the precipitator. Lowering the flue gas temperature to about 85°C by the addition of a venturi scrubber ahead of the centrifugal scrubber reduced the electrical resistivity of the fly ash another decade and allowed the operation of the precipitator without back corona.  相似文献   

13.
基于响应曲面法优化烧结烟气脱硫灰改性工艺   总被引:2,自引:1,他引:1  
采用BOX-Behnken的中心组合实验设计及响应面分析方法对半干法烧结烟气脱硫灰进行改性研究,得到脱硫灰转化率的预测模型。结果表明:通过该预测模型可以很好地描述脱硫灰的转化率与反应温度、反应时间和气固比等重要操作参数之间的关系,R2=0.9903。因素分析表明,反应温度对脱硫灰的转化率影响最大,同时反应温度和气固比的交互作用与反应温度和时间的交互作用对脱硫灰的转化率的影响作用相同。利用得到的改进预测模型可以计算脱硫灰的转化率。  相似文献   

14.
This paper describes some technical and economic aspects of the nahcolite ore injection process for the simultaneous removal of fly ash and sulfur oxides from stack gases. The process is capable of removing greater than 99% of the particulate matter and greater than 70% of the sulfur oxides present in such gases. In the process, nahcolite ore, a naturally occurring material containing 70 to 90% sodium bicarbonate, is ground to 90% passing through —200 mesh screens. Approximately 20% of the ground ore is used to precoat the filter bags in a baghouse filter while the remainder of the material is fed into the flue gas Just ahead of the baghouse. The flue gas is drawn through the baghouse by induced draft fans and sent up the stack. Most of the SO2 and practically all of the fly ash in the flue gas can be removed as the gas passes through the filter bags. The spent nahcolite ore and fly ash are collected and conveyed to waste disposal as landfill, or alternatively processed for insolubilization by coprecipitation prior to landfilling. The technical feasibility of the process has been demonstrated in both bench scale and pilot scale engineering studies. Economic analyses performed for the cases of plants located in the midwest and southwest indicate lower capital costs for the nahcolite injection process when compared to wet scrubbing. On an annual cost basis, the nahcolite ore Injection process is comparable in cost to wet scrubbing for the case of the southwestern power plant, and somewhat more expensive for the case of the midwestern plant.  相似文献   

15.
Dioxin contents in fly ash from large-scale MSW incinerators in Taiwan   总被引:6,自引:0,他引:6  
In this study, fly ash samples were collected from three municipal waste incinerators (MWI) in Taiwan. These MWIs investigated are equipped with different air pollution control devices (APCDs). Preliminary results indicated that 2,3,7,8-PCDD/Fs homologue patterns of various types of fly ash were quite similar for all three MWIs. Concentrations of higher-chlorinated congeners of PCDDs and PCDFs were remarkably higher than those of lower-chlorinated congeners. In the case of MSW-A, the PCDD/PCDF ratios of ashes were found in the decreasing order for cyclone, boiler and baghouse. The PCDD/PCDF ratios in various types of fly ash of MWI-B was boiler-A < boiler-B < ESP < boiler-C. As for MSW-C, no obvious trend has been observed for PCDD/PCDF ratio. However, the ratio in boiler ash was higher than that in baghouse ash of MWI-A. The dioxin contents in fly ash would increase as the fly ash passed through APCD zones. In other words, the environmental conditions of APCD may actually cause the increase of the dioxin contents in fly ash. The trend for dioxin contents in fly ash collected from three MSW incinerators investigated was MSW-C < MSW-A < MSW-B.  相似文献   

16.
The concept of electrostatic stimulation of fabric filtration (ESFF) has been investigated at pilot scale. The pilot unit consisted of a conventional baghouse in parallel with an ESFF baghouse, allowing direct comparison. All results reported in this paper are for pulse-cleaned bags in which the electric field was maintained parallel to the fabric surface. The performance of the ESFF baghouse has been superior to the parallel conventional baghouse by several measures. The ESFF baghouse demonstrated: (1) a reduced rate of pressure drop increase during a filtration cycle, (2) lower residual pressure drop, (3) stable operation at higher face velocities, and (4) improved particle removal efficiency. These benefits can be obtained with only minor modifications to conventional pulse-jet hardware and at low electrical power consumption. The indicated ability to operate at increased face velocities with only modest expenditure for electrical hardware leads to very favorable economic projections.  相似文献   

17.
Electrostatic precipitation is considered as an effective technology for fine particle removal. A lab-scale wet electrostatic precipitator (ESP) with wire-to-plate configuration was developed to study particle migration and collection. The performance of the wet ESP was evaluated in terms of the corona discharge characteristics, total removal efficiency and fractional removal efficiency. The corona discharge characteristics and particle removal abilities of the wet ESP were investigated and compared with dry ESP. Particle removal efficiency was influenced by discharge electrode type, SO2 concentration, specific collection area (SCA) and particle/droplet interaction. Results showed that the particle removal efficiency of wet ESP was elevated to 97.86% from 93.75% of dry ESP. Three types of discharge electrodes were investigated. Higher particle removal efficiency and larger migration velocity could be obtained with fishbone electrode. Particle removal efficiency decreased by 2.87% when SO2 concentration increased from 0 ppm to 43 ppm as a result of the suppression of corona discharge and particle charging. The removal efficiency increased with higher SCA, but it changed by only 0.71% with the SCA increasing from 25.0 m2/(m3/s) to 32.5 m2/(m3/s). Meanwhile, the increasing of particle and droplet concentration was favorable to the particle aggregation and improved particle removal efficiency.

Implications: This work tends to study the particle migration and collection under spraying condition. The performance of a wet electrostatic precipitator (ESP) is evaluated in terms of the corona discharge characteristics, total particle removal efficiency, and fractional particle removal efficiency. The effects of water droplets on particle removal, especially on removal of particles with different sizes, is investigated. The optimization work was done to determine appropriate water consumption, discharge electrode type, and specific collection area, which can provide a basis for wet ESP design and application.  相似文献   


18.
The coal-fired electric utility generation industry has been identified as the largest anthropogenic source of mercury (Hg) emissions in the United States. One of the promising techniques for Hg removal from flue gas is activated carbon injection (ACI). The aim of this project was to liberate Hg bound to fly ash and activated carbon after ACI and provide high-quality coal combustion products for use in construction materials. Both bench- and pilot-scale tests were conducted to liberate Hg using a thermal desorption process. The results indicated that up to 90% of the Hg could be liberated from the fly ash or fly-ash-and-activated-carbon mixture using a pilot-scale apparatus (air slide) at 538 degrees C with a very short retention time (less than 1 min). Scanning electron microscope (SEM) evaluation indicated no significant change in fly ash carbon particle morphology following the thermal treatment. Fly ash particles collected in the baghouse of the pilot-scale apparatus were smaller in size than those collected at the exit of the air slide. A similar trend was observed in carbon particles separated from the fly ash using froth flotation. The results of this study suggest a means for power plants to reduce the level of Hg in coal-combustion products and potentially recycle activated carbon while maintaining the resale value of fly ash. This technology is in the process of being patented.  相似文献   

19.
In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 microm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38-99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1-1 microm. In this size range, ESP and baghouse collection efficiencies are 85.79-98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.  相似文献   

20.
At the Monticello station, operated by the Texas Utilities Generating Company, lignite coal obtained locally in Titus and Hopkins Counties fuels each of the three units. Units 1 and 2 are identical 575-MW Combustion Engineering (CE) boilers, each of which discharges its effluent to a 36- compartment shake/deflate cleaned baghouse paralleled with four electrostatic precipitators (ESP). Unit 3 is a larger boiler and is followed by an ESP and a scrubber. The Unit 1 and 2 baghouses were designed to clean 80 percent of the flue gas. Since startup, these baghouses have regularly experienced flange-to-flange pressure drops in excess of 10 in. H2O, with large opacity spikes caused by ash bleeding through the bags after compartment cleanings. Because of higher-than-expected pressure drop, the baghouses receive only about 45-50 percent of the flue gas. Analysis has shown the Monticello lignite ash significantly differs from most other coal ashes. Testing has shown that the Monticello ash is not filtered effectively by many "standard" bag materials. However, this testing indicates that there are fabrics that show promise of eliminating the ash bleedthrough with little pressure drop penalty. Testing has also shown that injection of low concentrations (10-15 ppm) of ammonia (NH3) into the flue gas significantly decreases ash bleedthrough, so that with NH3 injection "standard" bag materials may perform adequately. Currently, fullcompartment testing of four fabrics, with and without NH3 injection, is under way at the Unit 1 baghouse. The research conducted at the Monticello station is reviewed in this paper and the encouraging results from the full-compartment tests are presented.  相似文献   