首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
In this study, landfill leachate treatment technologies alternative to anaerobic treatment were experimentally investigated. The emphasis was placed upon nitrogen removal through the use of struvite precipitation. Treatment technologies studied included struvite precipitation, low pH (acidic) air stripping, and activated sludge. Dilution of landfill leachate was used as a means to obtain appropriate quality for feeding the activated sludge process in some instances. Five main treatment combinations were applied. The first and second schemes were struvite precipitation followed by activated sludge process which was fed on undiluted and diluted (1:5) effluents. The third scheme was dilution, activated sludge and struvite precipitation. The fourth alternative was acidic air stripping, struvite precipitation and activated sludge process. The fifth scheme was acidic air stripping, activated sludge and struvite precipitation. All treatment schemes provided comparable COD and ammonia removals, all being around 90%. The treatment schemes incorporating the acidic air stripping, however, was found to be the most advantageous in terms of both efficiency and volume and aeration requirements of the activated sludge process since over 80% COD could be removed in the stripping step. Of the fourth and fifth alternative schemes, the fourth was the most efficient, providing 95% removal of both COD and ammonia. Initial dilution of the leachate at a 1:5 ratio was the least effective one, yielding 90% or lower removals for COD and ammonia. The first scheme, namely application of struvite precipitation to raw leachate followed by activated sludge with or without dilution, proved to be a practical system, providing over 85% COD and 99% ammonia removals. High organic loading up to 0.8 g COD/g VSS day was found to be applicable within this scheme.  相似文献   

2.
The behaviour of heavy metals was studied by carrying out a series of experiments with an activated sludge biological reactor (with pure oxygen), fed with different types of landfill leachate. The leachates used had been previously treated by the wet oxidation process and also by ammonia stripping. The experimentation aims were to evaluate both BOD and COD removal rates and the distribution of heavy metals concentrations between the liquid and solid phases. This latter data was used to confirm a mathematical model which predicts the distribution of heavy metals between the liquid and solid phases of a biological process.  相似文献   

3.
The aim of this research was to determine appropriate treatment technique for effective treatment of heavily polluted landfill leachate. We accomplished several treatment experiments: (i) aerobic biological treatment, (ii) chemical coagulation, (iii) advanced oxidation process (AOP) and (iv) several combined treatment strategies. Efficiency of these treatment procedures were monitored by analysing COD and colour removal. Leachate used for this study was taken from Matuail landfill site at Dhaka city. With extended aeration process which is currently used in Matuail landfill site for leachate treatment, maximum COD and colour removal of 36% and 20%, respectively could be achieved with optimum retention period of 7days. With optimum aluminium sulphate dose of 15,000mg/L and pH value of 7.0, maximum COD and colour removals of 34% and 66%, respectively were observed by using chemical coagulation. With optimum pH of 5.0 and optimum dosages of reagents having H(2)O(2)/Fe(2+) molar ratio of 1.3 the highest removal of COD and colour were found 68% and 87%, respectively with sludge production of 55%. Fenton treatment which is an advanced oxidation process was the most successful between these three separate treatment procedures. Among the combined treatment options performed, extended aeration followed by Fenton method was the most suitable one.  相似文献   

4.
Mathematical model analysis of Fenton oxidation of landfill leachate   总被引:2,自引:0,他引:2  
The treatment of concentrated landfill leachate rejected from reverse osmosis (RO) with Fenton process was studied, and the system model was developed through the examination of reaction kinetics. The leachate is typically non-biodegradable with low BOD5/COD ratio 0.01. The oxidation reactions of Fenton process was found to be a two-stage process, where a fast initial reaction (H2O2/Fe2+) was followed by a much slower one (H2O2/Fe3+). A simple and more accurate mathematics model based on COD and TOC removals has been derived successfully to describe the two-stage reaction kinetics. The two corresponding parameters involved in this model have been identified as the initial reaction rate and the maximum oxidation removal efficiency, respectively. It was found to be very useful for evaluating the performance of Fenton system and/or for process design using the two parameters under different experimental conditions.  相似文献   

5.
The objective of the present paper has been to study the effect of pig slurry waste type, fresh or anaerobically digested, and the effect of initial pH on ammonia air stripping from pig slurry waste at high temperature (80 degrees C). Stripping process as pre- or post-treatment to anaerobic digestion has been also evaluated. Treatment performances differ according to pig slurry type. When fresh pig slurry is used, despite working at 80 degrees C, a high initial pH (11.5) is required for complete ammonia removal. On the other hand, for digested pig slurry, complete ammonia removal without pH modification is possible and organic matter significantly less contaminates recovered ammonia salt. Batch anaerobic tests showed that ammonia air stripping is not an advisable pre-treatment to pig slurry anaerobic digestion.  相似文献   

6.
In order to determine the optimal dosage and type of coagulant for the physico-chemical treatment of leachate from the sanitary landfill of Merida, Mexico, a total of 864 jar tests were performed. Four metallic coagulants (ferric chloride, ferric sulphate, aluminium polychloride and aluminium sulphate) with doses ranging between 50 and 300 mg L(-1) and two polyelectrolytes (high-density anionic and cationic reagents) with doses from 2 to 12 mg L(-1) were tested. Neither an adequate type of coagulant nor an optimal dose could be found. The removal of contaminants was measured as total and dissolved chemical oxygen demand (COD). Soluble COD removal efficiencies were low, from 0 to 47%, with a 4% average value only. These low values of organic material removal were attributed to the particular characteristics of the Merida landfill leachate (low suspended solids concentration), so even with sweep-floc coagulation (300 mg L(-1) dose) only low COD removal efficiencies were obtained. A study of the suspended particle size distribution of the leachate was conducted in order to explain the poor performance. The particle size distribution ranged from 0.375 to 948.2 microm, with an average value of 22.97 microm. In a second step the optimal pH for physico-chemical treatment of these leachates was determined. Finally a greater than 90% removal of organic material, measured as suspended COD, was obtained at pH 2, which was considered as the optimal value.  相似文献   

7.
In order to reduce the environmental impact due to land disposal of oil fly ash from power plants and to valorize this waste material, the removal of vanadium was investigated using leaching processes (acidic and alkaline treatments), followed by a second step of metal recovery from leachates involving either solvent extraction or selective precipitation. Despite a lower leaching efficiency (compared to sulfuric acid), sodium hydroxide was selected for vanadium leaching since it is more selective for vanadium (versus other transition metals). Precipitation was preferred to solvent extraction for the second step in the treatment since: (a) it is more selective; enabling complete recovery of vanadate from the leachate in the form of pure ammonium vanadate; and (b) stripping of the loaded organic phase (in the solvent extraction process) was not efficient. Precipitation was performed in a two-step procedure: (a) aluminum was first precipitated at pH 8; (b) then ammonium chloride was added at pH 5 to bring about vanadium precipitation.  相似文献   

8.
This paper analyses the evolution of the physico-chemical characteristics of the leachate from the Central Landfill of Asturias (Spain), which has been operating since 1986, as well as different treatment options. The organic pollutant load of the leachate, expressed as chemical oxygen demand (COD), reached maximum values during the first year of operation of the landfill (around 80,000 mg/L), gradually decreasing over subsequent years to less than 5000 mg/L. The concentration of ammonium, however, has not decreased, presenting values of up to 2000 mg/L. When feasible, recirculation can greatly decrease the organic matter content of the leachate to values of 1500–1600 mg COD/L. Applying anaerobic treatment to leachates with a COD between 11,000 and 16,000 mg/L, removal efficiencies of 80–88% were obtained for organic loading rates of 7 kg COD/m3 d. For leachates with lower COD (4000–6000 mg/L), the efficiency decreased to around 60% for organic loading rates of 1 kg COD/m3 d.Applying coagulation–flocculation with iron trichloride or with aluminium polychloride, it was possible to reduce the non-biodegradable organic matter by 73–62% when treating old landfill leachate (COD: 4800 mg/L, BOD5: 670 mg/L), also reducing turbidity and colour by more than 97%. It is likewise possible to reduce the non-biodegradable organic matter that remains after biological treatment by adsorption with activated carbon, although adsorption capacities are usually low (from 15 to 150 mg COD/g adsorbent). As regards ammonium nitrogen, this can be reduced to final effluent values of 5 mg/L by means of nitrification/denitrification and to values of 126 mg/L by stripping at pH 12 and 48 h of stirring.  相似文献   

9.
The performance of a moving-bed biofilm reactor (MBBR) system with an anaerobic-aerobic arrangement was investigated to treat landfill leachate for simultaneous removal of COD and ammonium. It was found that the anaerobic MBBR played a major role in COD removal due to methanogenesis, and the aerobic MBBR acted as COD-polishing and ammonium removal step. The contribution of the anaerobic MBBR to total COD removal efficiency reached 91% at an organic loading rate (OLR) of 4.08 kgCOD/(m3d), and gradually decreased to 86% when feed OLR was increased to 15.70 kgCOD/(m3d). Because of the complementary function of the aerobic reactor, the total COD removal efficiency of the system had a slight decrease from 94% to 92% even though the feed OLR was increased from 4.08 to 15.70 kgCOD/(m3d). Hydraulic retention time (HRT) had a significant effect on NH+4-N removal; more than 97% of the total NH+4-N removal efficiency could be achieved when the HRT of the aerobic MBBR was more than 1.25 days. The anaerobic-aerobic system had a strong tolerance to shock loading. A decrease in COD removal efficiency of only 7% was observed when the OLR was increased by four times and shock duration was 24 h, and the system could recover the original removal efficiency in 3 days. The average sludge yield of the anaerobic reactor was estimated to be 0.0538 gVSS/gCOD rem.  相似文献   

10.
The aim of our study was to evaluate biotreatability of mature municipal landfill leachate by using white rot fungus and its extracellular enzymes. Leachates were collected in one active and one closed regional municipal landfill. Both chosen landfills were operating for many years and the leachates generated there were polluted by organic and inorganic compounds. The white rot fungus Dichomitus squalens was able to grow in the mature leachate from the closed landfill and as it utilizes present organic matter as a source of carbon, the results were showing 60% of DOC and COD removal and decreased toxicity to the bacterium Aliivibrio fischeri. On the other hand, growth of the fungus was inhibited in the presence of the leachate from the active landfill. However, when the leachate was introduced to a crude enzyme filtrate containing extracellular ligninolytic enzymes, removal levels of COD and DOC reached 61% and 44%, respectively. Furthermore, the treatment led to detoxification of the leachate to the bacterium Aliivibrio fischeri and to reduction of toxicity (42%) to the plant Sinapis alba. Fungal and enzymatic treatment seems to be a promising biological approach for treatment of mature landfill leachates and their application should be further investigated.  相似文献   

11.
Suspended solids, colour and chemical oxygen demand (COD) are among the main pollutants in landfill leachate. Application of physical or biological processes alone is normally not sufficient to remove these constituents, especially for leachate with a lower biochemical oxygen demand (BOD)/ COD ratio. The main objective of this research was to investigate the efficiency of coagulation and flocculation processes for removing suspended solids, colour and COD from leachate produced in a semi-aerobic landfill in Penang, Malaysia. A 12-month characterization study of the leachate indicated that it had a mean annual BOD/COD ratio of 0.15 and was partially stabilized, with little further biological degradation likely to occur. Particle size analysis of the raw leachate indicated that its 50th percentile (d50) was 11.68 microm. Three types of coagulants were examined in bench scale jar test studies: aluminium sulphate (alum), ferric chloride (FeCl3) and ferrous sulphate (FeSO4). The effects of agitation speed, settling time, pH, coagulant dosages and temperature were examined. At 300 rpm of rapid mixing, 50 rpm of slow mixing, and 60 min settling time, higher removals of suspended solids (over 95%), colour (90%) and COD (43%) were achieved at pH 4 and 12. FeCl3 was found to be superior to other coagulants tested. At pH 4 and 12, fair removal of suspended solids was observed at a reasonably low coagulant dose, i.e., 600 mg L(-1); hHowever, about 2500 mg L(-1) of coagulant was required to achieve good removals at pH 6. Better removals were achieved at higher temperature. The d50 of sludge after coagulation at pH 4 with a 2500 mg L(-1) FeCl3 dose was 60.16 microm, which indicated that the particles had been removed effectively from the leachate. The results indicate that coagulation and flocculation processes can be used effectively in integrated semi-aerobic leachate treatment systems, especially for removing suspended solids, colour and COD.  相似文献   

12.
The influence of different variables on the removal of ammonia nitrogen and COD from landfill leachate was investigated in a three-dimensional electrochemical reactor. Box–Behnken statistical experiment design and the response surface methodology were used to investigate operating condition effects, such as current density, activated carbon to water ratio and the reaction time, on ammonia nitrogen removal efficiency and COD removal efficiency. The positive and negative effects of variables and the interaction between variables on ammonia nitrogen removal and COD removal were determined. The response surface methodology models were derived based on the results and the response surface plots were developed accordingly.  相似文献   

13.
A laboratory bench-scale fixed-bed column study operated as a down-flow configuration was conducted to evaluate Sphagnum peat moss and crushed mollusk shells as natural low-cost adsorbents for the removal of heavy metals from aerated and unaerated synthetic landfill leachate. Columns were packed with 15 cm of prepared peat moss, or 15 cm adsorbent mixtures made up of peat moss and crushed mollusk shells (4.0–4.75 mm) from Lake Ontario at different bed depth ratios. Peat was found to have the best adsorption capacities in columns treating aerated synthetic leachate for cadmium and nickel with 78.6% and 83.8% removal efficiencies, respectively. The removal of chemical oxygen demand (COD) and total nitrogen from the synthetic leachate was also monitored to evaluate the potential effects of biological activity on heavy metal adsorption. Columns receiving unaerated raw synthetic leachates did not show any significant removal of COD and total nitrogen, whereas some reduction in COD and total nitrogen was noted in the columns treating aerated synthetic landfill leachate. The results suggested that biological activity and biofilm growth could positively contribute to heavy metal retention within the fixed-media biosorption columns.  相似文献   

14.
According to current environmental legislation concerned with water scarcity, paper industry is being forced to adopt a zero liquid effluent policy. In consequence, reverse osmosis (RO) systems are being assessed as the final step of effluent treatment trains aiming to recover final wastewater and reuse it as process water. One of the most important drawbacks of these treatments is the production of a retentated stream, which is usually highly loaded with biorecalcitrant organic matter and inorganics; and this effluent must meet current legislation stringent constraints before being ultimately disposed. The treatment of biorefractory RO retentate from a paper mill by several promising advanced oxidation processes (AOPs) - conventional Fenton, photo-Fenton and photocatalysis - was optimized considering the effect and interaction of reaction parameters; particularly using response surface methodology (RSM) when appropriate (Fenton processes). The economical cost of these treatments was also comparatively assessed. Photo-Fenton process was able to totally remove the COD of the retentate, and resulted even operatively cheaper at high COD removal levels than conventional Fenton, which achieved an 80% reduction of the COD at best. In addition, although these optimal results were produced at pH=2.8, it was also tested that Fenton processes are able to achieve good COD reduction efficiencies (>60%) without adjusting the initial pH value, provided the natural pH of this wastewater was close to neutral. Finally, although TiO(2)-photocatalysis showed the least efficient and most expensive figures, it improved the biodegradability of the retentate, so its combination with a final biological step almost achieved the total removal of the COD.  相似文献   

15.
Granule sequencing batch reactors (GSBR) were established for landfill leachate treatment, and the COD removal was analyzed kinetically using a modified model. Results showed that COD removal rate decreased as influent ammonium concentration increasing. Characteristics of nitrogen removal at different influent ammonium levels were also studied. When the ammonium concentration in the landfill leachate was 366 mg L−1, the dominant nitrogen removal process in the GSBR was simultaneous nitrification and denitrification (SND). Under the ammonium concentration of 788 mg L−1, nitrite accumulation occurred and the accumulated nitrite was reduced to nitrogen gas by the shortcut denitrification process. When the influent ammonium increased to a higher level of 1105 mg L−1, accumulation of nitrite and nitrate lasted in the whole cycle, and the removal efficiencies of total nitrogen and ammonium decreased to only 35.0% and 39.3%, respectively. Results also showed that DO was a useful process controlling parameter for the organics and nitrogen removal at low ammonium input.  相似文献   

16.
采用液膜萃取—酸析沉降—络合萃取组合工艺对有机磷阻燃剂生产废水进行预处理.最佳工艺条件为:液膜萃取时,液膜油相(表面活性剂与煤油的混合液)与内水相(H2SO4溶液)的体积比2∶1、乳化液膜与废水的体积比1∶8、废水pH 13.0,硫酸体积分数10%、煤油中表面活性剂质量浓度30 g/L、液膜萃取时间 15 min;酸析沉降时,废水pH l.0,酸析沉降时间30 min;络合萃取时,络合萃取剂(烷基叔胺N235与煤油的混合液)中烷基叔胺N235体积分数30%,络合萃取剂与废水的体积比1∶4,废水pH l.0,络合萃取时间30 min.在此最佳处理条件下,废水COD总去除率可达93%,吡啶去除率达99.9%以上,总磷去除率可达97%,BOD5/COD提高至0.32,有利于后续生化处理.  相似文献   

17.
Landfill leachates sampled during and after an accidental landfill fire were analysed and the levels of selected metals and chemical compounds compared to those occurring in the leachate under normal conditions. The fire at the landfill site was put out by excavation and cooling by use of water. The investigation during the fire and fire fight revealed a moderate increase in the level of nitrogen and also in pH and conductivity. Heavy metals and COD in the leachate showed considerably increased levels. In general, the determined variables appeared to normalise within one week after the fire was extinguished. It can be concluded that landfill fires extinguished by excavation may lead to elevated leachate levels of especially COD and heavy metals, but that this is only a short-term effect.  相似文献   

18.
分别采用4种纳滤膜处理某炼化公司的反渗透浓水。在初始COD为57.8 mg/L、TOC为23.94 mg/L、ρ(Ca2+)为289.0 mg/L、ρ(Mg2+)为54.6 mg/L、ρ(SO42-)为327.7 mg/L、ρ(Cl-)为1 106.8 mg/L的条件下,经纳滤处理后COD去除率达60%以上,污水COD降至30 mg/L以下,TOC去除率为31.9%~85.5%,阳离子的去除率为33.9%~97.0%,SO42-的去除率为63.3%~97.6%,Cl-的去除率较低。膜A的膜孔分布密集,具有很高的通量,对有机物和无机盐的截留效果较差;膜B和膜C对有机物和二价离子的截留效果较好;膜D的膜孔分布稀松,膜通量最低,对有机物和无机盐的截留能力均较强,但随出水体积的增加,对无机盐的截留能力下降较为明显。4种纳滤膜的性能各异,可满足不同企业的需求,具有良好的应用前景。  相似文献   

19.
This study investigates the effectiveness of using metal sulphide and carbonate precipitation mechanisms combined with a landfill‐derived mixed bacterial population. The study was conducted under controlled substrate conditions in anaerobic batch reactors. High chemical oxygen demand (COD):sulphate ratios, butyrate, propionate, and acetate were used anaerobically by bacteria for growth with associated sulphate reduction as well as sulphide and carbonate generation. Propionate and butyrate degradation occurred during sulphate reduction by sulphate‐reducing bacteria while acetate degradation was associated with methanogenesis by methanogenic bacteria. Using low COD, sulphate ratios showed limited acetate utilization, but sulphate reduction still occurred. Precipitation of Cd, Cu, Zn, Ni, and Fe sulphides occurred quickly and was completed in 15 to 30 days, while Ca, Mn, and Mg carbonates formed after 40 to 50 days and some soluble metal remained even after 120 days. The rate of metal precipitation was in the order of Cd>Cu>Zn>Ni>Fe>Mn>Mg>Ca. Bacterially mediated metal precipitation occurred slower than that recognized for chemical precipitation. These findings suggest that contaminant transport models based on chemical equilibrium metal behaviors may over‐predict metal removal by bio‐precipitation. © 2002 Wiley Periodicals, Inc.  相似文献   

20.
Advanced oxidation processes (AOPs) such as Fenton, electro-Fenton and photo-Fenton have been applied effectively to remove refractory organics from landfill leachate. The Fenton reaction is based on the addition of hydrogen peroxide to the wastewater or leachate in the presence of ferrous salt as a catalyst. The use of this technique has proved to be one of the best compromises for landfill leachate treatment because of its environmental and economical advantages. Fenton process has been used successfully to mineralize wide range of organic constituents present in landfill leachate particularly those recalcitrant to biological degradation. The present study reviews the use of Fenton and related processes in terms of their increased application to landfill leachate. The effects of various operating parameters and their optimum ranges for maximum COD and color removal are reviewed with the conclusion that the Fenton and related processes are effective and competitive with other technologies for degradation of both raw and pre-treated landfill leachate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号