首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
随着最严环保标准的出台及监管力度加大,对脱硫等环保设施的可靠性提出了更高要求。针对当前脱硫系统关键指标-脱硫效率,系统剖析了脱硫输入、运行参数、关键设备及仪表等诸方面影响脱硫效率的常见原因,并提出了相应的对策。  相似文献   

2.
程彬彬 《化工环保》2018,38(6):663-669
国家要求燃煤电厂锅炉要逐步改造为超低排放,相比新建锅炉或大型电厂锅炉,炼化企业自备电厂锅炉改造难度大。本文通过对炼化企业电厂锅炉现有环保设施和排放现状进行分析,对比了脱硫塔前干式除尘、塔内提级增效、塔后深度除尘等3种工艺技术方案的效果,结合已改造实例指出需关注设备腐蚀、SO3脱除、在线监测等方面问题,并提出深度改造技术方案和实施路线。  相似文献   

3.
介绍了火电厂环保设施运行状态及性能评价技术的创新性研究,包括研究方法、评价方法、评价技术及实际应用情况。该研究是继火电厂工程减排、结构减排后的重要管理技术创新,为进一步促进火电厂环保设施安全、稳定、可靠、经济运行,确保达标排放,推进火电行业管理减排和技术监督提供了技术支持。  相似文献   

4.
Microbial quality of air inside vehicle cabs is a major occupational health risk management issue in composting facilities. Large differences and discrepancies in protection factors between vehicles and between biological agents have been reported. This study aimed at estimating the mean protection efficiency of the vehicle cab environment against bioaerosols with higher precision. In-cab measurement results were also analysed to ascertain whether or not these protection systems reduce workers' exposure to tolerable levels. Five front-end loaders, one mobile mixer and two agricultural tractors pulling windrow turners were investigated. Four vehicles were fitted with a pressurisation and high efficiency particulate air (HEPA) filtration system. The four others were only equipped with pleated paper filter without pressurisation. Bacteria, fungi and endotoxins were measured in 72 pairs of air samples, simultaneously collected inside the cab and on the outside of the cab with a CIP 10-M sampler. A front-end loader, purchased a few weeks previously, fitted with a pressurisation and high efficiency particulate air (HEPA) filtration system, and with a clean cab, exhibited a mean protection efficiency of between 99.47% CI 95% [98.58-99.97%] and 99.91% [99.78-99.98%] depending on the biological agent. It is likely that the lower protection efficiency demonstrated in other vehicles was caused by penetration through the only moderately efficient filters, by the absence of pressurisation, by leakage in the filter-sealing system, and by re-suspension of particles which accumulated in dirty cabs. Mean protection efficiency in regards to bacteria and endotoxins ranged between 92.64% [81.87-97.89%] and 98.61% [97.41-99.38%], and between 92.68% [88.11-96.08%] and 98.43% [97.44-99.22%], respectively. The mean protection efficiency was the lowest when confronted with fungal spores, from 59.76% [4.19-90.75%] to 94.71% [91.07-97.37%]. The probability that in-cab exposure to fungi exceeded the benchmark value for short-term respiratory effects suggests that front-end loaders and mobile mixers in composting facilities should be fitted with a pressurisation and HEPA filtration system, regardless of whether or not the facility is indoors or outdoors. Regarding the tractors, exposure inside the cabs was not significantly reduced. However, in this study, there was a less than 0.01% risk of exceeding the bench mark value associated with fungi related short-term respiratory effects during an 1-h per day windrow turning operation. Pressurisation and a HEPA filtration system can provide safe working conditions inside loaders and mobile mixer with regard to airborne bacteria, fungi and endotoxins in composting facilities. However, regular thorough cleaning of the vehicle cab, as well as overalls and shoes cleaning, and mitigation of leakage in the filter-sealing system are necessary to achieve high levels of protection efficiency.  相似文献   

5.
The development of treatment technologies to limit the discharge of volatile organic compounds (VOCs) into the atmosphere has proceeded apace with the increasing use of soil venting for the remediation of contaminated soil. This article surveys the commonly-used emission control systems that have developed under air pollution control regulations in California. Emphasis is on equipment operating characteristics, typical performance results (destruction efficiencies of VOCs), and operating costs. A recently commercialized process for treating halogen-containing VOCs is described, and some operating and cost data are included.  相似文献   

6.
The operations of carbonization facilities for municipal solid waste treatment in Japan were examined. Input waste, system processes, material flows, quality of char and its utilization, fuel and chemical consumption, control of facility emissions, and trouble areas in facility operation were investigated and analyzed. Although carbonization is a technically available thermochemical conversion method for municipal solid waste treatment, problems of energy efficiency and char utilization must be solved for carbonization to be competitive. Possible solutions include (1) optimizing the composition of input waste, treatment scale, organization of unit processes, operational methods, and quality and yield of char on the basis of analysis and feedback of long-term operating data of present operating facilities and (2) securing stable char demands by linking with local industries such as thermal electric power companies, iron manufacturing plants, and cement production plants.  相似文献   

7.
再燃法烟气脱硝技术   总被引:4,自引:0,他引:4  
综述了再燃法烟气脱硝技术及其主要影响因素。通过对几种脱硝技术的分析比较,认为再燃脱硝是一种很有前景的脱硝技术,其投资和运行费用界于低NO。燃烧器和选择性催化还原技术之间,有喷氨条件下的先进再燃脱硝效率接近于选择性催化还原技术。总结了国内外对先进再燃脱硝技术各种参数影响条件的研究结果,并论述了该技术的应用要点。  相似文献   

8.
As the United States and other countries move toward a greater reliance on nuclear energy, it becomes increasingly important to characterize the environment around such facilities to protect society, human health, and the environment. This article presents an ecological, multidisciplinary approach to gathering the information needed to establish baselines, site new nuclear facilities, protect existing nuclear facilities and nuclear wastes, improve the basis for emergency planning, devise suitable monitoring schemes to ensure continued protection, provide data to track local and regional response changes, and provide for mitigation, remediation, and decommissioning planning. We suggest that there are five categories of information or data needs: (1) geophysical, sources, fate and transport; (2) biological systems; (3) human health; (4) stakeholder and environmental justice; and (5) societal, economic, and political. All of these categories are influenced by temporal and spatial patterns, vulnerabilities, and global changes. These informational needs are more expansive than the traditional site characterization but encompass a suite of physical, biological, and societal needs to protect all aspects of human health and the environment, not just physical health. We suggest that technical teams be established for each of the major informational categories, with appropriate representation among teams and with a broad involvement of a range of governmental personnel, natural and social scientists, Native Americans, environmental justice communities, and other stakeholders. Although designed for nuclear facilities, the templates and information teams can be adapted for other hazardous facilities. © 2013 Wiley Periodicals, Inc.  相似文献   

9.
Activated carbon fibers (ACFs) were used to remove SO(2) and NO from incineration flue gas. Three types of ACFs in their origin state and after pretreatment with HNO(3), NaOH, and KOH were investigated. The removal efficiencies of SO(2) and NO were determined experimentally at defined SO(2) and NO concentrations and at temperatures of 150, 200 and 260 degrees C. Experimental results indicated that the removal efficiencies of SO(2) and NO using the original ACFs were <56% and <27%, respectively. All ACFs modified with HNO(3), NaOH, and KOH solution could increase the removal efficiencies of SO(2) and NO. The mesopore volumes and functional groups of ACFs are important in determining the removal of SO(2) and NO. When the mesopore volumes of the ACFs are insufficient for removing SO(2) and NO, the functional groups on the ACFs are not important in determining the removal of SO(2) and NO. On the contrary, the effects of the functional groups on the removal of SO(2) and NO are more important than the mesopore volumes as the amount of mesopores on the ACFs is sufficient to remove SO(2) and NO. Moreover, the removal efficiencies of SO(2) and NO were greatest at 200 degrees C. When the inlet concentration of SO(2) increased to 600ppm, the removal efficiency of SO(2) increased slightly and the removal efficiency of NO decreased.  相似文献   

10.
Much labor, high technical skill and extreme cost are required to measure dioxins for obtaining the toxic equivalent quantity (TEQ) values. On one side, it was found that there were high amounts of chlorobenzenes (CBZs) in the flue gas from waste incineration facilities, and they are also thought to be one of the principal precursors for dioxins. The concentrations of CBZs could be used as a convenient substitute index to the TEQ values for controlling and monitoring dioxins in stack gas from waste incineration facilities as shown in another report. In this study, collection efficiencies in the sampling performed by a convenient train which was composed of two bottles containing water and diethylene glycol in a cooling box, recoveries in the evaporation of the extract by an evaporator, proper procedure of the concentration by nitrogen purge were investigated for measuring CBZs. It was found that tetra-, penta-, and hexa-chlorobenzenes (Cl4-6BZs) whose boiling points are higher than ca. 240 degrees C could be sufficiently collected and recovered in the sampling and the evaporation. For sufficient recoveries of Cl4-6BZs in the concentration by the nitrogen purge, the final volume should be larger than 200 microliters with a proper receiver of the K-D concentrator at 35 degrees C. However, Cl1-3BZs were lost in each of the procedures.  相似文献   

11.
Although production of sewage sludge increases every year, its proper treatment has only been recently raised as a new issue, as current landfill and ocean dumping arrangements are expected to become increasingly difficult to manage in the future. The Korean Ministry of Environment plans to diversify its processing facilities and expand its processing systems by 2011, with the purpose of processing all sludge produced in Korea. According to this plan, incineration (including incineration of municipal wastes) will process 30% of the entire sewage sludge throughout the country in 2011. This study reviews the characteristics of PAH, which is one of the organic substances found in sewage sludge during the incinerating process. The total amount of PAH produced from sewage sludge incineration was found to be 6.103 mg/kg on average, and investigation performed on 16 PAHs of inlets and outlets of the air control devices at five full-scale incineration facilities showed that concentrations of the PAHs on the inlet and on the outlet ranged from 3.926 to 925.748 microg/m(3) and from 1.153 to 189.449 microg/m(3), respectively. In the case of the incineration facility fed with municipal waste (95%) and sewage sludge (5%), the total of the PAH emissions concentration was higher than that found at the incineration facilities used exclusively to treat sewage. The combustion of waste vinyl and plastics contained in municipal waste fed into the facility might contribute to the high levels of PAHs in the stack gas. However more investigation is needed on the production mechanism of PAHs at different operating conditions of the incineration facilities, such as the types of waste, and other relevant factors.  相似文献   

12.
Statistics showed that approximately 1,195,000 refrigerator units (116,094 metric tons) were recycled annually in Korea’s formal sector. Although the recycling level for these was satisfactory, collecting and processing polyurethane at recycling centers (RCs) posed several problems, including the risk of fire from the incinerator, the generation of fugitive dust, and the high cost of disposal. The objective of our study is to provide an overview of refrigerator recycling and to introduce polyurethane solid refuse fuel (SRF) manufacturing facilities. These facilities, installed at four regional RCs in Korea, have a capacity of 800 kg/h, a motor of 476 kWh, and cost $664,300 (USD) to construct (criteria two facilities). According to our examination of the physico-chemical properties of SRF product, all results in categories have been satisfied with the quality standards. In terms of finances, RCs can reduce the total disposal cost from $160–175 to $60 by installing facilities, which results in savings of (on average) $180,546 annually. The Metropolitan Electronics Recycling Center, for example, has reduced its costs by $180,880 each year. Their return on investment was calculated to be about 3 years and 8 months (assuming no operating expenses) or 7 years and 4 months (including operating expenses).  相似文献   

13.
This paper discusses actions aimed at sustainable management of healthcare wastes (HCW) in China, taking into account the current national situation in this field, as well as the requirements deriving from the Stockholm Convention on Persistent Organic Pollutants and the WHO recommendations. By the end of 2005, there were 149 low-standard HCW disposal facilities in operation in China, distributed throughout different areas. According to the National Hazardous Waste and Healthcare Waste Disposal Facility Construction Plan, 331 modern, high-standard, centralized facilities will be built up in China in municipal level cities. Although incineration is still the main technical option for HCW disposal in China, it is expected that, especially for medium and small size facilities, non-incineration technologies will develop quickly and will soon become the main technical option. The basic management needs – both from the point of view of pollution control and final disposal – have been defined, and a system of technical and environmental standards has been formulated and implemented; however, there are still some shortages. This is particularly true when considering the best available techniques and best environmental practices developed under the Stockholm Convention, with which the present technological and managing situations are not completely compliant. In this framework, the lifecycle (from generation to final disposal of wastes) of HCW and holistic approaches (technology verification, facilities operation, environmental supervision, environmental monitoring, training system, financial mechanism, etc.) towards HCW management are the most important criteria for the sustainable and reliable management of HCW in China.  相似文献   

14.
通过对30家火电厂92台机组电缆安全状况的调查,研究了火电厂电缆安全技术管理体系的建立和执行情况、电缆设备状况、电缆安全技术措施以及运行管理状况。指出火电厂电缆安全状况在安全管理体系不健全、电缆设备安全隐患较多、安全技术措施不到位且运行管理相对较为松懈等问题,加大了火电厂电缆事故发生机率。针对电缆安全技术现状和管理现状,提出了提高和改善火电厂电缆安全水平的技术和管理措施。  相似文献   

15.
The available expertise on managing and operating solid waste management (SWM) facilities varies among countries and among types of facilities. Few experts are willing to record their experience, while few researchers systematically investigate the chains of events that could trigger operational failures in a facility; expertise acquisition and dissemination, in SWM, is neither popular nor easy, despite the great need for it. This paper presents a knowledge acquisition process aimed at capturing, codifying and expanding reliable expertise and propagating it to non-experts. The knowledge engineer (KE), the person performing the acquisition, must identify the events (or causes) that could trigger a failure, determine whether a specific event could trigger more than one failure, and establish how various events are related among themselves and how they are linked to specific operational problems. The proposed process, which utilizes logic diagrams (fault trees) widely used in system safety and reliability analyses, was used for the analysis of 24 common landfill operational problems. The acquired knowledge led to the development of a web-based expert system (Landfill Operation Management Advisor, http://loma.civil.duth.gr), which estimates the occurrence possibility of operational problems, provides advice and suggests solutions.  相似文献   

16.
Odour control at biowaste composting facilities   总被引:7,自引:0,他引:7  
There are several options to effectively reduce odorous emissions at composting facilities depending on the type of composting system used. Some of the more relevant measures for open and enclosed composting facilities are presented in this article. Results from different investigations on odour reduction efficiencies of biological waste gas treatment systems at various scales are presented. Biofilter/bioscrubber combinations were used and different biofilter materials were tested. The more relevant odorous substances in the waste gas were identified, and their reduction in the different systems was measured. The biofilter proved to be mainly responsible for efficient odour degradation. The investigations presented in this article revealed that screened compost was very effective, and proved to be a low cost biofilter material for odour degradation purposes. Screened compost showed higher degradation rates than a coke-compost mixture newly developed by the University of Leipzig. Furthermore, it seems that enclosed systems have advantages when compared to conventional open single bed biofilters.  相似文献   

17.
It is necessary to develop technical systems for controlling and monitoring dioxins in stack gas from waste incineration facilities. However, it required much labor, high technical skill and extreme cost to measure dioxins for obtaining the toxic equivalent quantity (TEQ) values. In this study, the positive correlations of the WHO-TEQ values of PCDDs/PCDFs/Co-PCBs or PCDDs/PCDFs with the conventional I-TEQ values of PCDDs/PCDFs were confirmed beforehand for a large number of incineration facilities in a wide concentration range of a hundred thousand times. The relationships between the TEQ values and the concentrations of total PCDDs/PCDFs, each toxic isomer of PCDDs/PCDFs, total Cl4-6BZs, or each homologue of Cl4-6BZs were investigated for various incineration facilities. And it was found that positive correlations of the TEQ values with the concentrations of total PCDDs/PCDFs, 2,3,4,7,8-P5CDF, or Cl5BZ for a large number of different incineration facilities and in a wide concentration range. Consequently, the concentrations of total PCDDs/PCDFs, 2,3,4,7,8-P5CDF and Cl5BZ, whose measuring methods are much easier than that of obtaining the TEQ values, could be used as convenient substitute indices to the TEQ values for controlling and monitoring dioxins in stack gas from various waste incineration facilities.  相似文献   

18.
泡沫分离法处理含Cr~(6+)废水   总被引:6,自引:3,他引:3  
采用间歇式泡沫分离法处理含Cr~(6+)废水,考察了各因素对Cr~(6+)去除效果的影响。通过正交实验分析确定的废水处理最佳工艺条件:废水pH 4.00,气体流量0.90 L/min,阳离子表面活性剂加入量300 mg/L。进水Cr~(6+)质量浓度为10 mg/L时,间歇运行的Cr~(6+)去除率为97.80%,连续运行的Cr~(6+)去除率为95.89%,出水均可达标排放。动力学实验结果表明,泡沫分离法去除Cr~(6+)的过程符合一级动力学的特征。对泡沫分离柱放大后的废水连续流实验分析结果表明,泡沫分离Cr~(6+)的效果比较稳定,但分离设备对废水处理效果有一定的影响。  相似文献   

19.
Sorting of waste wood is an important process practiced at recycling facilities in order to detect and divert contaminants from recycled wood products. Contaminants of concern include arsenic, chromium and copper found in chemically preserved wood. The objective of this research was to evaluate the sorting efficiencies of both treated and untreated parts of the wood waste stream, and metal (As, Cr and Cu) mass recoveries by the use of automated X-ray fluorescence (XRF) systems. A full-scale system was used for experimentation. This unit consisted of an XRF-detection chamber mounted on the top of a conveyor and a pneumatic slide-way diverter which sorted wood into presumed treated and presumed untreated piles. A randomized block design was used to evaluate the operational conveyance parameters of the system, including wood feed rate and conveyor belt speed. Results indicated that online sorting efficiencies of waste wood by XRF technology were high based on number and weight of pieces (70-87% and 75-92% for treated wood and 66-97% and 68-96% for untreated wood, respectively). These sorting efficiencies achieved mass recovery for metals of 81-99% for As, 75-95% for Cu and 82-99% of Cr. The incorrect sorting of wood was attributed almost equally to deficiencies in the detection and conveyance/diversion systems. Even with its deficiencies, the system was capable of producing a recyclable portion that met residential soil quality levels established for Florida, for an infeed that contained 5% of treated wood.  相似文献   

20.
After many years of research and debate, in August of 1997 the United States Environmental Protection Agency (EPA) issued New Source Performance Standards (NSPS) and Emission Guidelines (EG) for medical/infectious waste incinerators in the United States. These new emissions and operational standards establish considerably more restrictive limitations on air emissions for medical/infectious waste incinerators and will undoubtedly have a significant impact on the over 2300 hospitals presently operating an incinerator on-site. This paper will explore the options available to these facilities, and those facilities which may be considering installation of an incinerator, relative to achieving compliance with the NSPS and EG for medical/infectious waste incinerators.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号