首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The indoor and outdoor air quality of two staff quarters of Hong Kong Polytechnic University at Tsim Sha Tsui East (TSTE) and Shatin (ST) were investigated. The air sampling was carried out in winter for about two months starting from January to February of 1996. Fifteen flats from each staff quarter were randomly selected for indoor/outdoor air pollutant measurements. The pollutants measured were NOx, NO, NO2, SO2, CO, and O3. The variations of pollutant concentrations between indoor and outdoor air were investigated on weekday mornings, weekday evenings, weekend mornings, and weekend evenings. All indoor/outdoor pollutant concentrations measured did not exceed the ASHRAE/NAAQS standard. The carbon monoxide concentrations indoors were systemically higher than those outdoors at the TSTE and the ST quarters, both on weekdays and Sunday, which indicates there are CO sources indoors. Except for CO, the indoor levels of other pollutants (NOx, NO, NO2, SO2, and O3) are lower than those outdoors. There was a significant correlation (P < 0.05) between indoor and outdoor concentrations for SO2 and O3 at both the TSTE and the ST quarters. Except for O3, the mean concentrations of all the pollutants in the TSTE quarters, both indoor and outdoor, were higher than that of the ST quarters in all sampling periods. All indoor and outdoor O3 levels were lower at the TSTE quarters than those at the ST quarters. The O3 ratios of TSTE/ST were 0.72 outdoor and 0.79 indoor. This can be explained by the NO titration reaction through NO conversion to NO2.  相似文献   

2.
Particulate and gaseous emissions from indoor combustion appliances and smoking can elevate the indoor concentrations of various pollutants. Indoor pollutant concentrations resulting from operating one of several combustion appliances, or from sidestream tobacco smoke, were measured in a 27-m3 environmental chamber under varying ventilation rates. The combustion appliances investigated were gas-fired cooking stoves, unvented kerosene-fired space heaters, and unvented natural-gas-fired space heaters. Results showed elevated levels of carbon dioxide, carbon monoxide, nitric oxide, nitrogen dioxide, formaldehyde, and suspended particles from one or more of the pollutant sources investigated. Our findings suggest that, of the sources examined in this study, nitrogen dioxide from combustion appliances and particles from sidestream cigarette smoke are the most serious contaminants of indoor air, if we use existing standards and guidelines as the criteria. An emission rate model was used to quantify the strengths of the pollutant sources, which are reported in terms of the mass of pollutant emitted per energy unit of fuel consumed (in the case of gas and kerosene appliances) and per mass of tobacco combusted (in the case of smoking).  相似文献   

3.
Comparative overview of indoor air quality in Antwerp, Belgium   总被引:2,自引:0,他引:2  
This comprehensive study, a first in Belgium, aimed at characterizing the residential and school indoor air quality of subgroups that took part in the European Community Respiratory Health Survey and the International Study of Asthma and Allergy in Childhood [Masoli M, Fabian D, Holt S, Beasley R. Global Burden of Asthma, Medical Research Institute of New Zealand, University of Southampton; 2004.] questionnaire-based asthma and related illnesses studies. The principal aim was to perform a base-line study to assess the indoor air quality in Antwerp in terms of various gaseous and particulate pollutants. Secondly, it aimed to establish correlations between these pollutants investigated, the pollutant levels in the indoor and outdoor micro-environments, findings of the previous questionnaire-based studies and an epidemiological study which ran in conjunction with this study. Lastly, these results were compared and evaluated with current indoor and ambient guidelines in various countries This paper presents selected results on PM1, PM2.5 and PM10 mass concentrations and elemental C estimates as black smoke, as well as gaseous NO(2), SO(2), O(3) and BTEX concentrations of 18 residences and 27 schools. These are related to current guidelines of Flanders, Germany, Norway, China and Canada and evaluated with reference to selected similar studies. It was found that indoor sources such as tobacco smoking and carpets, the latter causing re-suspension of dust, are responsible for elevated indoor respirable particulate matter and place school children and residents at risk. Both PM2.5 and PM10 equalled or exceeded the current guidelines adopted by Flanders, noting that 12-h and 24-h PM2.5 were compared with an annual limit value. Indoor and ambient NO(2) concentrations in the school campaign were higher than the annual EU ambient norm. The other studied pollutant levels were below the current guidelines.  相似文献   

4.
Given the shrinking spatial contrasts in outdoor air pollution in Switzerland and the trends toward tightly insulated buildings, the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA) needs to understand to what extent outdoor air pollution remains a determinant for residential indoor exposure. The objectives of this paper are to identify determining factors for indoor air pollution concentrations of particulate matter (PM), ultrafine particles in the size range from 15 to 300 nm, black smoke measured as light absorbance of PM (PMabsorbance) and nitrogen dioxide (NO2) and to develop predictive indoor models for SAPALDIA. Multivariable regression models were developed based on indoor and outdoor measurements among homes of selected SAPALDIA participants in three urban (Basel, Geneva, Lugano) and one rural region (Wald ZH) in Switzerland, various home characteristics and reported indoor sources such as cooking. Outdoor levels of air pollutants were important predictors for indoor air pollutants, except for the coarse particle fraction. The fractions of outdoor concentrations infiltrating indoors were between 30% and 66%, the highest one was observed for PMabsorbance. A modifying effect of open windows was found for NO2 and the ultrafine particle number concentration. Cooking was associated with increased particle and NO2 levels. This study shows that outdoor air pollution remains an important determinant of residential indoor air pollution in Switzerland.  相似文献   

5.
Indoor and outdoor endotoxin in PM2.5 was measured for the very first time in Santiago, Chile, in spring 2012. Average endotoxin concentrations were 0.099 and 0.094 [EU/m3] for indoor (N = 44) and outdoor (N = 41) samples, respectively; the indoor–outdoor correlation (log-transformed concentrations) was low: R =  0.06, 95% CI: (− 0.35 to 0.24), likely owing to outdoor spatial variability.A linear regression model explained 68% of variability in outdoor endotoxins, using as predictors elemental carbon (a proxy of traffic emissions), chlorine (a tracer of marine air masses reaching the city) and relative humidity (a modulator of surface emissions of dust, vegetation and garbage debris). In this study, for the first time a potential source contribution function (PSCF) was applied to outdoor endotoxin measurements. Wind trajectory analysis identified upwind agricultural sources as contributors to the short-term, outdoor endotoxin variability. Our results confirm an association between combustion particles from traffic and outdoor endotoxin concentrations.For indoor endotoxins, a predictive model was developed but it only explained 44% of endotoxin variability; the significant predictors were tracers of indoor PM2.5 dust (Si, Ca), number of external windows and number of hours with internal doors open. Results suggest that short-term indoor endotoxin variability may be driven by household dust/garbage production and handling. This would explain the modest predictive performance of published models that use answers to household surveys as predictors. One feasible alternative is to increase the sampling period so that household features would arise as significant predictors of long-term airborne endotoxin levels.  相似文献   

6.
The results of more than 1 yr of air monitoring inside and outside of five homes in each of two communities are presented for SO2, NO2, mass respirable particles, SO4, Al, Br, Cl, Mn, Na, and V. Outdoor measurements across the home site in each city are consistent with proximity to outdoor sources. Looking across indoor residential sites in each city, the home appears to alter outdoor concentrations in several ways. Indoor level of SO2, SO4, Mn, and V are lower than those measured outdoors. These constituents are thought generally to result from outdoor sources. The other constituents studied are at times found in excess within homes. In some cases the source or sources of excess concentration of a particular constituent could be identified; often, however, the source of excess indoor concentration could not be identified.  相似文献   

7.
Cooking and heating with coal and biomass is the main source of household air pollution in China and a leading contributor to disease burden. As part of a baseline assessment for a household energy intervention program, we enrolled 205 adult women cooking with biomass fuels in Sichuan, China and measured their 48-h personal exposure to fine particulate matter (PM2.5) and carbon monoxide (CO) in winter and summer. We also measured the indoor 48-h PM2.5 concentrations in their homes and conducted outdoor PM2.5 measurements during 101 (74) days in summer (winter). Indoor concentrations of CO and nitrogen oxides (NO, NO2) were measured over 48-h in a subset of ~ 80 homes. Women's geometric mean 48-h exposure to PM2.5 was 80 μg/m3 (95% CI: 74, 87) in summer and twice as high in winter (169 μg/m3 (95% CI: 150, 190), with similar seasonal trends for indoor PM2.5 concentrations (winter: 252 μg/m3; 95% CI: 215, 295; summer: 101 μg/m3; 95% CI: 91, 112). We found a moderately strong relationship between indoor PM2.5 and CO (r = 0.60, 95% CI: 0.46, 0.72), and a weak correlation between personal PM2.5 and CO (r = 0.41, 95% CI: − 0.02, 0.71). NO2/NO ratios were higher in summer (range: 0.01 to 0.68) than in winter (range: 0 to 0.11), suggesting outdoor formation of NO2 via reaction of NO with ozone is a more important source of NO2 than biomass combustion indoors. The predictors of women's personal exposure to PM2.5 differed by season. In winter, our results show that primary heating with a low-polluting fuel (i.e., electric stove or wood-charcoal) and more frequent kitchen ventilation could reduce personal PM2.5 exposures. In summer, primary use of a gaseous fuel or electricity for cooking and reducing exposure to outdoor PM2.5 would likely have the greatest impacts on personal PM2.5 exposure.  相似文献   

8.
In the frame of the OFFICAIR project, indoor and outdoor PM2.5 samples were collected in office buildings across Europe in two sampling campaigns (summer and winter). The ability of the particles to deplete physiologically relevant antioxidants (ascorbic acid (AA), reduced glutathione (GSH)) in a synthetic respiratory tract lining fluid, i.e., oxidative potential (OP), was assessed. Furthermore, the link between particulate OP and the concentration of the PM constituents was investigated.The mean indoor PM2.5 mass concentration values were substantially lower than the related outdoor values with a mean indoor/outdoor PM2.5 mass concentration ratio of 0.62 and 0.61 for the summer and winter campaigns respectively. The OP of PM2.5 varied markedly across Europe with the highest outdoor OPAA m−3 and OPGSH m−3 (% antioxidant depletion/m3 air) values obtained for Hungary, while PM2.5 collected in Finland exhibited the lowest values. Seasonal variation could be observed for both indoor and outdoor OPAA m−3 and OPGSH m−3 with higher mean values during winter. The indoor/outdoor OPAA m−3 and OPGSH m−3 ratios were less than one with 4 and 17 exceptions out of the 40 cases respectively. These results indicate that indoor air is generally less oxidatively challenging than outdoors. Correlation analysis revealed that trace elements play an important role in determining OP, in particular, the Cu content. Indoor air chemistry might affect OP since weaker correlations were obtained for indoor PM2.5. Our findings also suggest that office workers may be exposed to health relevant PM constituents to a different extent within the same building.  相似文献   

9.
Data from suburban residences in the Boston metropolitan area reveal a potential adverse impact on indoor air quality from woodburning in woodstoves and fireplaces. Ambient pollutant concentrations at each residence were compared to corresponding pollutant levels indoors at three locations (kitchen, bedroom, and activity room). Individual gaseous pollutant samples were averaged on an hourly basis while 24-h integrated samples of particulate matter were obtained. Ten gaseous pollutants were sampled along with total suspended particulates (TSP). Chemical analyses further determined ten components of TSP including trace metals, benzo-a-pyrene(B)aP, respirable suspended particulates (RSP), and water soluble sulfates and nitrates. Monitoring lasted two weeks at each residence and was conducted under occupied, real-life, conditions. Observed, elevated indoor concentrations of TSP, RSP, and BaP are attributed to woodburning. Data indicate that average indoor TSP concentrations during woodburning periods were about three times corresponding levels during nonwoodburning periods. The primary 24-h national ambient air quality standard (NAAQS) for TSP was exceeded once indoors during fireplace use, and the secondary, 24-h TSP NAAQS, was also exceeded indoors by RSP concentrations. Indoor BaP concentrations during woodstove use averaged five times more than during nonwoodburning periods. At this stage, results are only indicative, but the potential impact from elevated indoor concentrations of TSP, RSP, and BaP, attributed to woodburning, may have long-term health implications.  相似文献   

10.
Determinants of outdoor, indoor and personal concentrations of nitrogen dioxide (NO2) were assessed in a subset of pregnant women of the Spanish INMA (Environment and Childhood) Study. Home indoor and outdoor NO2 concentrations were measured during 48 h with passive samplers for 50 and 58 women from the INMA cohorts of Valencia and Sabadell, respectively. Women from Sabadell also carried personal NO2 samplers during the same period. Data on time–activity patterns, socio-economic characteristics, and environmental exposures were obtained through questionnaires. Multiple linear regression models were developed to predict NO2 levels.In Valencia, median outdoor NO2 levels (42 µg/m3) were higher than median indoor levels (36 µg/m3). In Sabadell, personal NO2 showed the highest median levels (40 µg/m3), followed by indoor (32 µg/m3) and outdoor (29 µg/m3) levels. Personal exposure to NO2 correlated best with the indoor NO2 levels. Temporal and traffic-related variables were significant predictors for outdoor NO2 levels. Thirty-two percent of the indoor NO2 variability in the two cohorts was explained by outdoor NO2 levels and the use of the gas appliances. The model for personal exposure accounted for 59% of the variance in NO2 levels in Sabadell with four predictor variables (outdoor and indoor NO2 levels, time spent in outdoor environments and time exposed to a gas cooker). No significant association was found between personal or indoor NO2 levels and exposure to environmental tobacco smoke (ETS) at home.Personal NO2 levels were found to be strongly influenced by indoor NO2 concentrations. The study supports the use of time–activity patterns along with indoor measurements to predict personal exposure to traffic-related air pollution.  相似文献   

11.
On 15 dates, 5000 measurements of carbon monoxide (CO) were made in downtown commercial settings in four California towns and cities (San Francisco, Palo Alto, Mountain View, and Los Angeles), using personal exposure monitoring (PEM) instruments. Altogether, 588 different commercial settings were visited, and indoor and outdoor locations were sampled at each setting. On 11 surveys, two CO PEM's were carried about 0.15–6 m apart, giving 1706 pairs of observations that showed good agreement: the correlation coefficient was r = 0.97 or greater, and the average difference was less than 1 ppm (μL/L) by volume. Of 210 indoor settings (excluding parking garages), 204 (97.1%) had average CO concentrations less than 9 ppm (μL/L); of 368 outdoor settings, 356 (96.7%) had average CO concentrations less than 9 ppm (μL/L). For a given date and commercial setting, CO concentrations were found to be relatively stable over time, permitting levels to be characterized by making only brief visits to each setting. The data indicate that most commercial settings experience CO concentrations above zero indoors, because CO tends to seep into buildings from vehicular emissions outside. Levels in these locations usually are not above 5 ppm (μL/L) and seldom are higher than the U.S. health-related ambient air quality standards for CO. However, indoor garages and buildings with attached indoor parking areas are exceptions and can experience relatively high CO concentrations.  相似文献   

12.
Assessment of airborne organophosphorus pesticides in houses of young children (1-6 years old) and childcare facilities was conducted following pesticide applications in an agricultural community in Japan. Trichlorfon and fenitrothion, applied in two separate periods, were frequently detected from outdoor and indoor air. Dichlorvos, the primary degradation product of trichlorfon, was also detected after the application of trichlorfon. Both the outdoors and indoor concentration of applied pesticide were shown to increase with decreasing distance from the pesticide-applied farm. Indoor concentration of these pesticides significantly correlated with outdoor concentration (p=0.001 for trichlorfon and p=0.001 for fenitrothion), indicating infiltration of applied pesticide inside. Ratio of indoor to outdoor concentration (I/O ratio) of fenitrothion was higher for houses with windows open during the application than those with closed windows (median value: 0.74 vs. 0.16, p=0.003). However, a similar trend was not observed for trichlorfon as well as dichlorvos in the first period. Dichlorvos was found to have a higher I/O ratio than trichlorfon during the period, and clear correlation between indoor concentrations of dichlorvos and those of trichlorfon suggested increased decomposition of trichlorfon in the indoor environment. Daily inhalation exposure estimated by using the fixed measurement data and time-activity questionnaire ranged from 0 to 35 ng/kg/day for trichlorfon, from 0 to 26 ng/kg/day for dichlorvos, and from 0 to 44 ng/kg/day for fenitrothion. Median inhalation exposure from indoor air accounted for 74%, 86.3%, and 45% of the daily inhalation exposure, respectively. For kindergarteners or nursery school children, inhalation exposure at childcare facilities was comparable with or more than that at home, indicating that pollution level at childcare facilities had potential of high impact on children's exposure. Estimated daily inhalation exposures were inversely correlated to the proximity of their activity location to the pesticide-applied farm.  相似文献   

13.
To date, personal volatile organic compounds (VOCs) exposure and residential indoor and outdoor VOCs levels have not been characterized in Korea. In this study, residential indoor and outdoor VOCs concentrations were measured and compared simultaneously with the personal exposure for each of 30 participants in a medium city, Asan, and in a metropolitan city, Seoul. Factors that influence personal VOCs exposures were assessed in relation to house characteristics and time activity information. All VOC concentrations were measured using passive samplers during a 24-h period and analyzed using GC-MS. Ten target VOCs were benzene, trichloroethylene, toluene, o-xylene, p-xylene, ethylbenzene, MIBK, n-octane, styrene, and 1,2-dichlorobenzene. Residential indoor and outdoor VOCs concentrations measured in Seoul were significantly higher than those in Asan. Indoor/outdoor (I/O) ratios for all target compounds ranged from 0.94 to 1.51 and I/O ratios of Asan were a little higher than those of Seoul. Results indicate that time activity information can be used to predict personal exposures, although such predictions will result in an over estimation compared to measured exposures. Factors which influence the indoor VOCs level and its personal exposure in relation to house characteristics included house age, indoor smoking, and house type.  相似文献   

14.
Contrasting effects of the dilution of indoor generated pollutants and the energy efficiency of heating and ventilating air conditioning systems (HVAC) for indoor air quality (IAQ) and thermal comfort were studied for 10 Kuwaiti residences. The levels of volatile organic compounds (VOCs) and the calculated cooling load of the HVAC systems were used as indicators for the IAQ and for the energy consumption, respectively. Air exchange rates and VOCs levels (both indoor and outdoor) were measured. It was found that the outdoor VOC concentrations were always less than the indoor values. Therefore reduction of indoor VOC levels can be accomplished either by increasing the ratio of the makeup air to the recirculation air of the HVAC system or by increasing the infiltration airflow rate through openings. A single compartment IAQ model, modified by the authors, was used to test for the variation in the above two dilution modes and to test the performance sensitivity. Hence, the optimum parameters in terms of IAQ and energy consumption were determined. The results indicated that it was necessary to increase the ratio of the makeup air to the recirculation air from its typical design value of 0.5 to a range of 0.7-1.3 in order to reduce indoor VOC to acceptable levels.  相似文献   

15.
The measurement campaigns have been done in the rural community of Niska Banja, a spa town located in southern Serbia, to evaluate population exposure to natural radioactivity. After a screening survey in 200 houses, annual radon and thoron concentrations were measured in 34 houses, and in 2004 a detailed investigation was carried out at six houses with elevated indoor radon concentrations. The paper presents the results of these detailed measurements. The complementary techniques were applied to determine radon and thoron concentrations in indoor air, in soil gas, radon exhalation from soil, soil permeability, and indoor and outdoor gamma doses. Soil and water samples were collected and analysed in the laboratory. Indoor radon and thoron concentrations were found to be more than 1kBqm(-3) and 200Bqm(-3), respectively. Extremely high concentrations of soil-gas radon (>2000kBqm(-3)) and radon exhalation rates (1.5mBqm(-2)s(-1)) were observed. These results will be utilised to set up the methodology for a more systematic investigation.  相似文献   

16.
A radon survey has been carried out around the town of Niska Banja (Serbia) in a region partly located over travertine formations, showing an enhanced level of natural radioactivity. Outdoor and indoor radon concentrations were measured seasonally over the whole year, using CR-39 diffusion type radon detectors. Outdoor measurements were performed at 56 points distributed over both travertine and alluvium sediment formations. Indoor radon concentrations were measured in 102 living rooms and bedrooms of 65 family houses. In about 50% of all measurement sites, radon concentration was measured over each season separately, making it possible to estimate seasonal variations, which were then used to correct values measured over different periods, and to estimate annual values. The average annual indoor radon concentration was estimated at over 1500 Bq/m3 and at about 650 Bq/m3 in parts of Niska Banja located over travertine and alluvium sediment formations, respectively, with maximum values exceeding 6000 Bq/m3. The average value of outdoor annual radon concentration was 57 Bq/m3, with a maximum value of 168 Bq/m3. The high values of indoor and outdoor radon concentrations found at Niska Banja make this region a high natural background radiation area. Statistical analysis of our data confirms that the level of indoor radon concentration depends primarily on the underlying soil and building characteristics.  相似文献   

17.
Measurement of personal exposure to nitrogen dioxide for short and long term was made with a sensitive NO2 passive sampler by volunteer housewives and office workers in different seasons. These measurements were compared with the simultaneous measurement of outdoor and indoor concentration of the participants. A common result over all the measurements is the potential effect of using an unvented space heater to increase personal exposure. Mean personal exposure and indoor concentration are higher than outdoor levels elevated by the samples exposed to pollutant produced from the heater. Without an NO2 source indoors, the mean outdoor concentrations are always highest among the data of measurement. A time-weighted indoor/outdoor activity model gives modestly improved estimates of personal exposure over those predicted from measured indoor concentrations alone.  相似文献   

18.
Matched pairs of indoor and outdoor air samples from residences in Greensboro, NC; Baton Rouge/ Geismar, LA; Deer Park/Pasadena, TX; Elizabeth/Bayonne, NJ: Antioch/W. Pittsburg, CA; and several small communities in the Los Angeles area were collected and analyzed for over 20 volatile organic compounds during the period from 1981 to 1984. Indoor (I) medians and maximum levels were higher than the corresponding outdoor (O) concentrations over the large majority of chemicals studied. In some cases, e.g., chloroform, dichlorobenzenes, and tetrachloroethylene, the median ratios (I/O) were greater than 10.  相似文献   

19.
Samples of respirable particulate matter collected during a personal monitoring study in Topeka, KS, were analyzed for iron, aluminum, and lead content. The sampling protocol and instrumentation are described in detail. Lead indoor concentrations (median = 79 ng/m3) were found to be less than both personal (median = 112 ng/m3) and outdoor lead concentrations (median = 106 ng/m3). The indoor, outdoor, and personal levels of iron and aluminum were not significantly different. In addition, it was determined that outdoor respirable particulate mass does not correlate well with the personal or indoor metal concentrations, and that the amount of time spent in motor vehicles is a relatively good indicator of lead exposures. The relationships between indoor, outdoor, and personal lead are discussed in greater detail, with references to supporting evidence from other studies.  相似文献   

20.
This report presents results of a review of available methods for control of environmental hazards applied to indoor air pollutants. Indoor air pollution originates from transport of ambient outdoor air contaminants into occupied spaces by natural infiltration ventilation, or by mechanical ventilation using outdoor makeup air, plus contributions from indoor emission sources. When air exchange with the external ambient environment is reduced to conserve energy, contributions from indoor emission sources may dominate indoor air pollutant levels. This paper identifies alternative methods available to control indoor air pollutant exposures. The performance characteristics of ventilation systems and of air cleaning devices used in mixed modes for ventilation of occupied spaces are described. Models for predicting effectiveness of several alternative modes are reviewed, with field trial validation results cited where available. Results of previous confined-space studies are briefly reviewed as points of departure for consideration of necessary air quality, ventilation, and air cleaning. Understanding of indoor air contaminant generation and controls is aided by examination of earlier studies of indoor air quality, using modern perspectives on occupational environmental health and hygiene.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号