A subcommittee of the Nordic Committee for Building Codes has released guidelines for building regulations regarding indoor air quality, especially concerning ventilation. The main features of the guidelines, such as acceptable outdoor air quality for ventilation and minimum outdoor air flows for dwellings and offices, are presented and discussed. Mechanical ventilation is, in principle, required in all buildings including dwellings, due to the requirement of a minimum outdoor air change of 0.5 h−1 and the normal highly airtight nature of new buildings. The guidelines are a basis for designing energy-efficient buildings while maintaining an indoor air quality which provides acceptable comfort and does not impair health.  相似文献   

2.
There is growing evidence that projected climate change has the potential to significantly affect public health. In the UK, much of this impact is likely to arise by amplifying existing risks related to heat exposure, flooding, and chemical and biological contamination in buildings. Identifying the health effects of climate change on the indoor environment, and risks and opportunities related to climate change adaptation and mitigation, can help protect public health.We explored a range of health risks in the domestic indoor environment related to climate change, as well as the potential health benefits and unintended harmful effects of climate change mitigation and adaptation policies in the UK housing sector. We reviewed relevant scientific literature, focusing on housing-related health effects in the UK likely to arise through either direct or indirect mechanisms of climate change or mitigation and adaptation measures in the built environment. We considered the following categories of effect: (i) indoor temperatures, (ii) indoor air quality, (iii) indoor allergens and infections, and (iv) flood damage and water contamination.Climate change may exacerbate health risks and inequalities across these categories and in a variety of ways, if adequate adaptation measures are not taken. Certain changes to the indoor environment can affect indoor air quality or promote the growth and propagation of pathogenic organisms. Measures aimed at reducing greenhouse gas emissions have the potential for ancillary public health benefits including reductions in health burdens related heat and cold, indoor exposure to air pollution derived from outdoor sources, and mould growth. However, increasing airtightness of dwellings in pursuit of energy efficiency could also have negative effects by increasing concentrations of pollutants (such as PM2.5, CO and radon) derived from indoor or ground sources, and biological contamination. These effects can largely be ameliorated by mechanical ventilation with heat recovery (MVHR) and air filtration, where such solution is feasible and when the system is properly installed, operated and maintained. Groups at high risk of these adverse health effects include the elderly (especially those living on their own), individuals with pre-existing illnesses, people living in overcrowded accommodation, and the socioeconomically deprived.A better understanding of how current and emerging building infrastructure design, construction, and materials may affect health in the context of climate change and mitigation and adaptation measures is needed in the UK and other high income countries. Long-term, energy efficient building design interventions, ensuring adequate ventilation, need to be promoted.  相似文献   

3.
The indoor concentration of suspended particulate matter (SPM) was measured in forty-four retrofitted and tight dwellings, which had electric cooking and were central heated and where the basic ventilation rate in median amounted 0.23 air changes per hour as measured with a tracer dilution method. The indoor concentration of SPM was in median 230 μg/m3 with a strong correlation to the tobacco consumption (rs=0.716), but with no correlation to the frequency of airing or the basic ventilation rate. Tobacco smoking seems to be the main indoor source of SPM in contemporary dwellings. The importance of these findings is underlined by epidemiologic studies on passive smoking and health. Air quality standards for the ambient air are based on certain risk groups such as infants, children, persons with chronic obstructive lung disorders, and indoor air standards should be based on the same concepts of health protection.  相似文献   

4.
Dilution of indoor air contaminants with less contaminated outdoor air is the most common strategy for control of indoor air quality. Unfortunately this strategy frequently imposes a substantial energy burden. If the contaminants are associated with occupants and their activities, a ventilation control system based on the carbon dioxide level in the controlled space is shown to relieve this energy burden. A test was carried out in the Fridley, MN, Junior High School Music Department to obtain air quality, energy, and subjective response data on an Automatic Variable Ventilation System. A control system with both CO2 and temperature inputs was devised to control the use of outdoor air. Infiltration measurements lead to a quantitative measure of ventil3tion efficiency. This in turn led to recommendations for air circulation patterns in rooms. The measured ventilation efficiency enabled energy and CO2 models to fit measured data. Energy savings of approximately 20% were found for this application. Subjective response of the occupants also was measured. A special questionnaire, subjected to statistical analysis, showed that the subjects felt warmer with increased CO2 in the room air.  相似文献   

5.
The effect of reduced air infiltration rate caused by energy-saving measures has been studied by comparing the indoor climate in 25 sealed apartments with the conditions in 25 unsealed apartments in four seasonal periods. The indoor temperature in bedrooms during February and March was 19.3 °C in sealed apartments and 17.8 °C in unsealed apartments, and the occupants in the sealed apartments correspondingly complained less frequently of draught problems during the winter. When the frequency of window opening was at its minimum (February–March), there was a higher indoor humidity in sealed compared with unsealed apartments, and this probably accounts for an increased occurrence of house-dust mites in dust from the sealed apartments during the winter. Also in February–March there was a slight increase in the concentration of suspended particulate matter in sealed apartments. Considering health effects of a reduced air infiltration rate, it can be predicted that the increased indoor air humidity will indirectly increase the frequency and severity of house-dust mite allergy in the population.  相似文献   

6.
LR- 115 plastic track detectors have been used to measure indoor radon level in some dwellings of Una district, Himachal Pradesh, India. The annual average radon concentration in dwellings in most of the villages falls in the range of the action level recommended by the International Commission on Radiological Protection. The radon values in some of the dwellings exceed the action level and may be unsafe from the health hazard point of view. The indoor radon values are in general higher in winter than in summer. Uranium, radium and radon exhalation studies have also been carried out in soil samples collected from these areas. A good correlation is obtained between uranium concentration in the soil and indoor radon in dwellings. The soil radon exhalation rate also correlates with the uranium concentration in soil.  相似文献   

7.
Considering the role of radon in epidemiology, an attempt was made to make a nation-wide map of indoor 222Rn and 220Rn for India. More than 5000 measurements have been carried out in 1500 dwellings across the country comprising urban and nonurban locations. The solid state nuclear track detectors based twin cup 222Rn/220Rn discrimination dosimeters were deployed for the measurement of indoor 222Rn, 220Rn and their progeny levels. The geometric means of estimated annual inhalation dose rate due to indoor 222Rn, 220Rn and their progeny in the dwellings was 0.94 mSvy−1 (geometric standard deviation 2.5). It was observed that the major contribution to the indoor inhalation dose was due to indoor 222Rn and its progeny. However, the contribution due to indoor 220Rn and its progeny was not trivial as it was found to be about 20% of the total indoor inhalation dose rates. The indoor 222Rn levels in dwellings was significantly different depending on the nature of walls and floorings.  相似文献   

8.
A sample of 58 occupied homes in Rochester, NY, most of which incorporated special builder-designed weatherization components, were studied to assess (1) the effectiveness of construction techniques designed to reduce air leakage; (2) the indoor air quality and air-exchange rates in selected airtight houses, and (3) the impact on indoor air quality of mechanical ventilation systems employing air-to-air heat exchangers. The “specific leakage area” was measured in each house using the fan pressurization technique. Houses built with polyethylene vapor barriers and joint-sealing were as a group 50% tighter than a similar group of houses without such components. Mechanical ventilation systems with air-to-air heat exchangers were installed in nine relatively airtight houses, some of which had gas stoves and/or tobacco smoking occupants. Air-exchange rates and indoor concentrations of radon (Rn), formaldehyde (HCHO), nitrogen dioxide (NO2), and humidity were measured in each house for 1-week periods with and without mechanical ventilation. More detailed measurements, including concentrations of carbon monoxide and inhalable particulates, were made in two of these houses by a mobile laboratory. In all nine houses, air-exchange rates were relatively low (0.2–0.5 ach) without mechanical ventilation, and yet indoor concentrations of Rn, HCHO, and NO2 were below existing guidelines. Mechanical ventilation systems were effective in further reducing indoor contaminant concentrations. We conclude that when contaminant source strengths are low, acceptable indoor air quality can be compatible with low air-exchange rates.  相似文献   

9.
Results of indoor gamma radiation and radon measurements in 95 wooden dwellings located in a Norwegian thorium-rich carbonatite area using thermoluminescent dosemeters and CR-39 alpha track detectors, respectively, are reported together with a thorough analysis of the indoor data with regard to geological factors. Slightly enhanced radium levels and thorium concentrations of several thousands Bq kg(-1) in the carbonatites were found to cause elevated indoor radon-222 levels and the highest indoor gamma dose rates ever reported from wooden houses in Norway. An arithmetic mean indoor gamma dose rate of 200 nGy h(-1) and a maximum of 620 nGy h(-1) were obtained for the group of dwellings located directly on the most thorium-rich bedrock.  相似文献   

10.
This report presents results of a review of available methods for control of environmental hazards applied to indoor air pollutants. Indoor air pollution originates from transport of ambient outdoor air contaminants into occupied spaces by natural infiltration ventilation, or by mechanical ventilation using outdoor makeup air, plus contributions from indoor emission sources. When air exchange with the external ambient environment is reduced to conserve energy, contributions from indoor emission sources may dominate indoor air pollutant levels. This paper identifies alternative methods available to control indoor air pollutant exposures. The performance characteristics of ventilation systems and of air cleaning devices used in mixed modes for ventilation of occupied spaces are described. Models for predicting effectiveness of several alternative modes are reviewed, with field trial validation results cited where available. Results of previous confined-space studies are briefly reviewed as points of departure for consideration of necessary air quality, ventilation, and air cleaning. Understanding of indoor air contaminant generation and controls is aided by examination of earlier studies of indoor air quality, using modern perspectives on occupational environmental health and hygiene.  相似文献   

11.
Efforts to reduce the energy needs to heat or cool dwellings have the potential to create new health hazards. Increases in indoor levels of radon and its progeny from the reduction in air exchange rates add a substantial radioactive burden to the general population. Other indoor pollutants reaching critical concentrations in homes with low air exchange rates are CO and NO2 from unvented combustion in gas stoves and heaters, tobacco smoke, and asbestos fibers. In addition, insulation materials and certain types of furniture may contribute the toxicant formaldehyde diffusing from foam injected walls or chipboard. Risk estimations using linear dose-response relationships show risk factors per kWh saved which are orders of magnitude greater than for a kWh produced by large power plants using coal, oil, gas, or uranium.  相似文献   

12.
Dust accumulating on hot indoor surfaces, e.g., heaters and light fixtures, are likely to emit chemicals when heated. Using in vitro techniques we have investigated biological effects of extracts from such emissions from three indoor and two outdoor dust samples heated at 50-250 degrees C. The cell cultures were a lung epithelial cell line (A549) and primary immune cells [peripheral blood mononuclear cell (PBMCs)]. We found that a 24-h incubation with extracts generated at 200 degrees C or higher inhibit both proliferation and mitochondrial activity of the epithelial cells. At non-cytotoxic concentrations, the extracts generated at 100 degrees C or higher inhibit the release of the pro-inflammatory cytokine tumor necrosis factor-alpha (TNFalpha) from lipopolysaccharide-stimulated PBMCs. The results imply that temperatures relevant for surfaces of equipment in the indoor environment cause emissions from dust that may have an impact on indoor air quality and affect the respiratory health of building occupants.  相似文献   

13.
This paper reports on radon concentrations in dwellings from fifty different locations of India. The incorporated data were obtained using the passive solid state nuclear track detector technique. The estimated geometric mean value for India is 67.1 Bq m(-3). Chuadanga in Bangladesh had the lowest observed indoor radon concentration of 27.3 Bq m(-3) and Una in the northern part of India had the highest concentration of 281.5 Bq m(-3). This paper discusses the national geometrical mean value in terms of the national geometric mean values of other countries and also in terms of the geological influence. The estimated indoor radon levels are compared with the indoor radon levels as recommended by the International Commission on Radiation Protection (ICRP). It was observed that there are several locations in India where dwellings have higher indoor radon levels than the ICRP recommended value and requires some sort of intervention from regulating authorities. The mean value for indoor radon level given in the report of UNSCEAR 2000 for India needs to be revised.  相似文献   

14.
In recent years, scientist have come to realize that contaminated air inside buildings is a major route of human exposure to certain air pollutants. While scientific interest in the problem continues to grow, efforts to measure indoor pollution concentrations, define exposure levels, and estimate health risks remain in their infancy. Within this arena, policymakers must deal with the question of how best to protect public health and safety in the face of incomplete and often contradictory information. In the past, official response to environmental pollution has traditionally taken the form of “control by regulation.” However, creation of a regulatory framework for indoor air quality poses special policy issues that suggest the need to explore alternative modes of intervention. Ambient outdoor air is a public good, in the sense that enjoyment by one individual in no way detracts from use or enjoyment by others. Indoor air, on the other hand, is not a public good, especially in private residences. Costs and benefits of maintaining adequate indoor air quality are internalized within households, suggesting the possibility of a private demand for clean indoor air. Promulgation of indoor air quality standards and other regulations must confront the fact that individuals are already making decisions about their own air quality. Regulations might or might not improve these decisions. Development of effective and reasonable policy requires an appreciation of the scope for private action and consideration of the likelihood that public intervention will foster improved private choices. Among the logical and relatively inexpensive modes of intervention are public information programs, development of simple warning devices, and product testing and labeling.  相似文献   

15.
Sixteen existing multi-family buildings (94 apartments) in Finland and 20 (96 apartments) in Lithuania were investigated prior to their renovation in order to develop and test out a common protocol for the indoor environmental quality (IEQ) assessment, and to assess the potential for improving IEQ along with energy efficiency. Baseline data on buildings, as well as data on temperature (T), relative humidity (RH), carbon dioxide (CO2), carbon monoxide (CO), particulate matter (PM), nitrogen dioxide (NO2), formaldehyde, volatile organic compounds (VOCs), radon, and microbial content in settled dust were collected from each apartment. In addition, questionnaire data regarding housing quality and health were collected from the occupants. The results indicated that most measured IEQ parameters were within recommended limits. However, different baselines in each country were observed especially for parameters related to thermal conditions and ventilation. Different baselines were also observed for the respondents' satisfaction with their residence and indoor air quality, as well as their behavior related to indoor environment. In this paper, we present some evidence for the potential in improving IEQ along with energy efficiency in the current building stock, followed by discussion of possible IEQ indicators and development of the assessment protocol.  相似文献   

16.
Ambient temperature may influence both the emission and the perception of human odor. This paper studies how human odor is perceived at different temperatures. The intensity of human odor in an auditorium was judged by an odor panel in an adjacent space. The ventilation rate of the occupied auditorium was 5–17 L/sec person. A continuous sample of odorous air was exhausted from the auditorium through a glass tube to an odor test station. One-half of the air flow was heated 1–7 K, and the other half was unheated. The odor panel was asked to compare the odor intensity of the two air flows. The air flow judged to have the strongest odor was stepwise dilluted with clean air (air temperature difference maintained). The dilution required to provide the same odor intensity in the two air flows was estimated. At air temperatures 23–32 °C no significant influence of temperature on perceived intensity of body odor was found. The ventillation requirement in auditoria and similar spaces is likely to be independent of the temperature level, provided that the occupants are kept thermally neutral or cooler, so that little or no perspiration occurs.  相似文献   

17.
Human civilization is currently facing two particular challenges: population growth with a strong trend towards urbanization and climate change. The latter is now no longer seriously questioned. The primary concern is to limit anthropogenic climate change and to adapt our societies to its effects. Schools are a key part of the structure of our societies. If future generations are to take control of the manifold global problems, we have to offer our children the best possible infrastructure for their education: not only in terms of the didactic concepts, but also with regard to the climatic conditions in the school environment. Between the ages of 6 and 19, children spend up to 8 h a day in classrooms. The conditions are, however, often inacceptable and regardless of the geographic situation, all the current studies report similar problems: classrooms being too small for the high number of school children, poor ventilation concepts, considerable outdoor air pollution and strong sources of indoor air pollution.There have been discussions about a beneficial and healthy air quality in classrooms for many years now and in recent years extensive studies have been carried out worldwide. The problems have been clearly outlined on a scientific level and there are prudent and feasible concepts to improve the situation. The growing number of publications also highlights the importance of this subject. High carbon dioxide concentrations in classrooms, which indicate poor ventilation conditions, and the increasing particle matter in urban outdoor air have, in particular, been identified as primary causes of poor indoor air quality in schools. Despite this, the conditions in most schools continue to be in need of improvement. There are many reasons for this. In some cases, the local administrative bodies do not have the budgets required to address such concerns, in other cases regulations and laws stand in contradiction to the demands for better indoor air quality, and sometimes the problems are simply ignored.This review summarizes the current results and knowledge gained from the scientific literature on air quality in classrooms. Possible scenarios for the future are discussed and guideline values proposed which can serve to help authorities, government organizations and commissions improve the situation on a global level.  相似文献   

18.
This paper summarizes recent data on the occurrence of major organic compounds (benzene, toluene, xylenes, styrene, acetaldehyde, formaldehyde, naphthalene, limonene, α-pinene and ammonia, classified by the European Commission's INDEX strategy report as the priority pollutants to be regulated) and evaluates accordingly cancer and non-cancer risks posed by indoor exposure in dwellings and public buildings in European Union (EU) countries. The review process indicated that significant differences in indoor air quality exist within and among the countries where data were available, indicating corresponding differences in sources and emission strength of airborne chemicals, identified or not. Conservative exposure limits were not exceeded for non-carcinogenic effects, except for formaldehyde; for carcinogenic agents the estimated risks were up to three orders of magnitude higher than the one (10(-6)) proposed as acceptable by risk management bodies. However, the risk assessment evaluation process faces crucial difficulties, either due to the relative paucity of indoor air quality measurements in many EU countries, or by the lack of sampling consistency in the already existing studies, indicating the need for additional measurements of indoor air quality following a harmonized sampling and analytical protocol. Additionally, uncertainties embodied in the cancer potency factors and exposure limit values impose further difficulties in substance prioritization and risk management.  相似文献   

19.
Measurements of indoor atmospheric environment were carried out in a day nursery and a kindergarten, in which natural air infiltration supplied the rooms with only 1–2 m3 fresh air per person and hour under the prescribed occupancy. The exposure situation from the field was duplicated under controlled conditions in a climate chamber. The results indicate unacceptably high concentrations of carbon dioxide, and emphasize the need for more elaborate building design in airtight buildings.  相似文献   

20.
Radon adsorption by activated charcoal collectors such as PicoRad radon detectors is known to be largely affected by temperature and relative humidity. Quantitative models are, however, still needed for accurate radon estimation in a variable environment. Here we introduce a temperature calibration formula based on the gas adsorption theory to evaluate the radon concentration in air from the average temperature, collection time, and liquid scintillation count rate. On the basis of calibration experiments done by using the 25 m3 radon chamber available at the National Institute of Radiological Sciences in Japan, we found that the radon adsorption efficiency may vary up to a factor of two for temperatures typical of indoor conditions. We expect our results to be useful for establishing standardized protocols for optimized radon assessment in dwellings and workplaces.  相似文献   