首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Sewer network construction is insufficient in China currently. The management for sewer network is very disordered in China. Maintenance is far from enough for current sewer networks in China. China’s top priority for sewer networks is to elevate its overall performance. The new technical route is an optimal option for sewer maintenance in China. Chinese authorities and the public have largely ignored sewer networks; however, various problems are emerging nationwide with the increase construction of new sewers. The current state of sewer network construction, administration, and maintenance in China is comprehensively reviewed in this study. Serving about 444 million people, 511,200 km of sewer lines are located in urban areas. In 2014, $7 billion was invested in sewer network construction. However, both the sewer pervasion rate and the per capita sewer length were significantly lower than those in developed countries. Sewer administrative agencies in local governments are uncoordinated. Laws, regulations, and standards are incomplete, and some practices are unscientific. The future situation of sewer maintenance is extremely grim because sewer corrosion control measures have not been launched. Moreover, inspection and rehabilitation chiefly rely on traditional approaches. In contrast, the overall market share of innovative technologies is very low owing to high cost, funds shortage, and technical limitations. Approaches such as liner inversion cured-in-place pipe, pull-in ultraviolet light cured liners, and spiral wound lining are applied mostly in economically developed regions. According to status and problem analyses, China’s top priority will be to conduct aggressive maintenance work in sewer networks in the future. New technical route, corrosion control - periodic visualized inspection - trenchless rehabilitation, could be the best option for future sewer maintenance in China. Instructions and opportunities for applying this technical route are discussed in detail in this study. Finally, additional factors in the development of sewer networks in China are suggested.  相似文献   

2.
A comprehensive pollutant transformation model for sewer systems is established. The model comprises fermentation, sulfate reduction and ammonification processes. Biochemical reactions related to distinct carbon sources are depicted in the model. Pollutant transformation is attributed to different biochemical reaction processes. Presently, several activated sludge models (ASMs) have been developed to describe a few biochemical processes. However, the commonly used ASM neither clearly describe the migratory transformation characteristics of fermentation nor depict the relationship between the carbon source and biochemical reactions. In addition, these models also do not describe both ammonification and the integrated metabolic processes in sewage transportation. In view of these limitations, we developed a new and comprehensive model that introduces anaerobic fermentation into the ASM and simulates the process of sulfate reduction, ammonification, hydrolysis, acidogenesis and methanogenesis in a gravity sewer. The model correctly predicts the transformation of organics including proteins, lipids, polysaccharides, etc. The simulation results show that the degradation of organics easily generates acetic acid in the sewer system and the high yield of acetic acid is closely linked to methanogenic metabolism. Moreover, propionic acid is the crucial substrate for sulfate reduction and ammonification tends to be affected by the concentration of amino acids. Our model provides a promising tool for simulating and predicting outcomes in response to variations in wastewater quality in sewers.  相似文献   

3.
Green source Ep was extracted from marine alga waste. The molecule model structure of Ep was studied and constructed. PAC-Ep coagulation system improves the efficiency of removal efficiency. Synergistic effects between NPs and HA make a big difference to enhance efficiency. Mechanism is charge neutralization, hydrogen bonding and adsorbing-complexing Enteromorpha polysaccharide (Ep) extracted from alga a novel green coagulant aid for nanoparticles (NPs) and heavy metal ions removal and the structure of EP was intensively studied in this study. The integration of Ep with polyaluminum chloride (PAC-Ep) coagulants exhibited higher coagulation performance than that of the polyaluminum chloride (PAC) because of the negatively charged NPs suspension and humic aid (HA) solution. Significant high removal efficiencies of dissolved organic matter (94.1%), turbidity (99.3%) and Zn ions (69.3%) were achieved by the PAC-Ep coagulants. The dual-coagulation properties of PAC-Ep for different pollutants was based on multiple mechanisms, including (i) Al3+ charge neutralization; (ii) hydroxy aluminum hydroxyl bridging formed polynuclearhydroxy complexes bridge and sweep colloidal particles; (iii) adsorption and bridging of Ep chain for the NPs and heavy metal ions. Results indicated that the destabilization of colloid was induced by the coexisting HA and higher removal was achieved as ions adsorption was enhance in the presence of HA complexation. On the basis of that, the extraction of polysaccharide is a promising candidate for its high coagulation performance in water treatment.  相似文献   

4.
CNT-PVA membrane was fabricated and compared with polymeric membranes. The separation performance was evaluated by homemade and cutting fluid emulsions. The three membranes show similar oil retention rates. CNT-PVA membranes have higher permeation fluxes compared with polymeric membranes. CNT-PVA membrane shows higher fouling resistance. Membrane separation is an attractive technique for removal of emulsified oily wastewater. However, polymeric membranes which dominate the current market usually suffer from severe membrane fouling. Therefore, membranes with high fouling resistance are imperative to treat emulsified oily wastewater. In this study, carbon nanotube-polyvinyl alcohol (CNT-PVA) membrane was fabricated. And its separation performance for emulsified oily wastewater was compared with two commercial polymeric membranes (PVDF membrane and PES membrane) by filtration of two homemade emulsions and one cutting fluid emulsion. The results show that these membranes have similar oil retention efficiencies for the three emulsions. Whereas, the permeation flux of CNT-PVA membrane is 1.60 to 3.09 times of PVDF membrane and 1.41 to 11.4 times of PES membrane, respectively. Moreover, after five consecutive operation circles of filtration process and back flush, CNT-PVA membrane can recover 62.3% to 72.9% of its initial pure water flux. However, the pure water flux recovery rates are only 24.1% to 35.3% for PVDF membrane and 6.0% to 26.3% for PES membrane, respectively. Therefore, CNT-PVA membrane are more resistant to oil fouling compared with the two polymeric membranes, showing superior potential in treatment of emulsified oily wastewater.  相似文献   

5.
Dielectrophoresis (DEP) process could enhance the removal the Cd2+ and Pb2+ with less absorbent. The removal rates of both Cd2+ and Pb2+ increased with the increase of voltage. The overall removal rate of Cd2+ and Pb2+ in the binary system is higher than that of Cd2+ or Pb2+ in the single system. DEP could cause considerable changes of the bentonite particles in both surface morphology and microstructure. Dielectrophoresis (DEP) was combined with adsorption (ADS) to simultaneously and effectively remove Cd2+ and Pb2+ species from aqueous solution. To implement the process, bentonite particles of submicro-meter size were used to first adsorb the heavy metal ions. These particles were subsequently trapped and removed by DEP. The effects of the adsorbent dosage, DEP cell voltage and the capture pool numbers on the removal rate were investigated in batch processes, which allowed us to determine the optimal experimental conditions. The high removal efficiency, 97.3% and 99.9% for Cd2+ and Pb2+, respectively, were achieved when the ions are coexisting in the system. The microstructure of bentonite particles before and after ADS/DEP was examined by scanning electron microscopy. Our results suggest that the dielectrophoresis-assisted adsorption method has a high capability to remove the heavy metals from wastewater.  相似文献   

6.
The existence of three-phase separator did not affect COD removal in the EAnCMBR. The existence of three-phase separator aggravated methane leakage of EAnCMBR. The existence of three-phase separator aggravated membrane fouling rate of EAnCMBR. Start-up of EAnCMBR equipped three-phase separator was slightly delayed. The three-phase separator is a critical component of high-rate anaerobic bioreactors due to its significant contribution in separation of biomass, wastewater, and biogas. However, its role in an anaerobic membrane bioreactor is still not clear. In this study, the distinction between an external anaerobic ceramic membrane bioreactor (EAnCMBR) unequipped (R1) and equipped (R2) with a three-phase separator was investigated in terms of treatment performance, membrane fouling, extracellular polymers of sludge, and microbial community structure. The results indicate that the COD removal efficiencies of R1 and R2 were 98.2%±0.4% and 98.1%±0.4%, respectively, but the start-up period of R2 was slightly delayed. Moreover, the membrane fouling rate of R2 (0.4 kPa/d) was higher than that of R1 (0.2 kPa/d). Interestingly, the methane leakage from R2 (0.1 L/d) was 20 times higher than that from R1 (0.005 L/d). The results demonstrate that the three-phase separator aggravated the membrane fouling rate and methane leakage in the EAnCMBR. Therefore, this study provides a novel perspective on the effects of a three-phase separator in an EAnCMBR.  相似文献   

7.
• A model-free sewer-WWTP integrated control was proposed. • A dynamic discrete control based on the water level was developed. • The approach could improve the sewer operation against flow fluctuation. • The approach could increase transport capacity and enhance pump efficiency. This study aims to propose a multi-point integrated real-time control method based on discrete dynamic water level variations, which can be realized only based on the programmable logic controller (PLC) system without using a complex mathematical model. A discretized water level control model was developed to conduct the real-time control based on data-automation. It combines the upstream pumping stations and the downstream influent pumping systems of wastewater treatment plant (WWTP). The discretized water level control method can regulate dynamic wastewater pumping flow of pumps following the dynamic water level variation in the sewer system. This control method has been successfully applied in practical integrated operations of sewer-WWTP following the sensitive flow disturbances of the sewer system. The operational results showed that the control method could provide a more stabilized regulate pumping flow for treatment process; it can also reduce the occurrence risk of combined sewer overflow (CSO) during heavy rainfall events by increasing transport capacity of pumping station and influent flow in WWTP, which takes full advantage of storage space in the sewer system.  相似文献   

8.
The UASB system successfully treated sulfamethoxazole pharmaceutical wastewater. High concentration sulfate of this wastewater was the main refractory factor. UASB recovery performance after a few days of inflow arrest was studied. The optimal UASB operating conditions for practical application were determined. Treatment of sulfamethoxazole pharmaceutical wastewater is a big challenge. In this study, a series of anaerobic evaluation tests on pharmaceutical wastewater from different operating units was conducted to evaluate the feasibility of using anaerobic digestion, and the results indicated that the key refractory factor for anaerobic treatment of this wastewater was the high sulfate concentration. A laboratory-scale up-flow anaerobic sludge blanket (UASB) reactor was operated for 195 days to investigate the effects of the influent chemical oxygen demand (COD), organic loading rate (OLR), and COD/SO42? ratio on the biodegradation of sulfamethoxazole in pharmaceutical wastewater and the process performance. The electron flow indicated that methanogenesis was still the dominant reaction although sulfidogenesis was enhanced with a stepwise decrease in the influent COD/SO42? ratio. For the treated sulfamethoxazole pharmaceutical wastewater, a COD of 4983 mg/L (diluted by 50%), OLR of 2.5 kg COD/(m3·d), and COD/SO42? ratio of more than 5 were suitable for practical applications. The recovery performance indicated that the system could resume operation quickly even if production was halted for a few days.  相似文献   

9.
Sludge digestion is critical to control the spread of ARGs from wastewater to soil. Fate of ARGs in three pretreatment-AD processes was investigated. UP was more efficient for ARGs removal than AP and THP in pretreatment-AD process. The total ARGs concentration showed significant correlation with 16S rRNA gene. The bacteria carrying ARGs could be mainly affiliated with Proteobacteria. Sewage sludge in the wastewater treatment plants contains considerable amount of antibiotic resistance genes (ARGs). A few studies have reported that anaerobic digestion (AD) could successfully remove some ARGs from sewage sludge, but information on the fate of ARGs in sludge pretreatment-AD process is still very limited. In this study, three sludge pretreatment methods, including alkaline, thermal hydrolysis and ultrasonic pretreatments, were compared to investigate the distribution and removal of ARGs in the sludge pretreatment-AD process. Results showed that the ARGs removal efficiency of AD itself was approximately 50.77%, and if these three sludge pretreatments were applied, the total ARGs removal efficiency of the whole pretreatment-AD process could be improved up to 52.50%–75.07%. The ultrasonic pretreatment was more efficient than alkaline and thermal hydrolysis pretreatments. Although thermal hydrolysis reduced ARGs obviously, the total ARGs rebounded considerably after inoculation and were only removed slightly in the subsequent AD process. Furthermore, it was found that the total ARGs concentration significantly correlated with the amount of 16S rRNA gene during the pretreatment and AD processes, and the bacteria carrying ARGs could be mainly affiliated with Proteobacteria.  相似文献   

10.
COD/N at low ratios (0–0.82) improved N removals of CANON. CANON performance decreased after COD/N up to 0.82. The relative abundance of AOB decreased continuously with increasing COD/N. AOB outcompeted at a high COD load led to CANON failure. The relative abundance of AnAOB decreased and increased with increasing COD/N. The effects of increasing COD/N on nitrogen removal performance and microbial structure were investigated in a SBR adopting a completely autotrophic nitrogen removal over nitrite process with a continuous aeration mode (DO at approximately 0.15–0.2 mg/L). As the COD/N increased from 0.1 to≤0.59, the nitrogen removal efficiency (NRE) increased from 88.7% to 95.5%; while at COD/N ratios of 0.59–0.82, the NRE remained at 90.7%–95.5%. As the COD/N increased from 0.82 to 1.07, the NRE decreased continuously until reaching 60.1%. Nitrosomonas sp. (AOB) and Candidatus Jettenia (anammox bacteria) were the main functional genera in the SBR. As the COD/N increased from 0.10 to 1.07, the relative abundance of Nitrosomonas decreased from 13.4% to 2.0%, while that of Candidatus Jettenia decreased from 35% to 9.9% with COD/N<0.82 then increased to 45.4% at a COD/N of 1.07. Aerobic heterotrophic bacteria outcompeted AOB at high COD loadings (650 mg/L) because of oxygen competition, which ultimately led to deteriorated nitrogen removal performance.  相似文献   

11.
A new electrocoagulation process based on bipolar aluminum electrode is proposed. The placement angles of bipolar electrode are key parameter. The numerical simulations support the experimental results. We in our previous study reported the wireless electrocoagulation (WEC) based on bipolar electrochemistry for water purification. One of the most important advantages of WEC is the omission of ohmic connection between bipolar electrode (BPE) and power supply, and thus the electrochemical reactions on BPE are driven by electric field in solution induced by driving electrodes. In this study, the impact of placement angle of bipolar aluminum electrode on WEC was investigated to provide a detailed analysis on the correlations between the bipolar electrode placement angle and bipolar electrocoagulation reactions. The results showed that the WEC cell with a horizontal BPE placed at 0° produced the maximum dissolved aluminum coagulant, accounting for 71.6 % higher than that with a vertical one placed at 90°. Moreover, the finite element simulations of current and potential distribution were carried out along the surface of BPE at different placement angles, revealing the mechanism of different BPE placement angles on aluminum dissolution rates in WEC system.  相似文献   

12.
A two-stage BTF system was established treating odorous off-gas mixture from a WWTP. The two-stage BTF system showed resistance for the lifting load of H2S and VOSC. Miseq Illumina sequencing showed separated functional microbial community in BTFs. Avoiding H2S inhibition and enhancement of VOSC degradation was achieved. Key control point was discussed to help industrial application of the system. Simultaneous removal of hydrogen sulfide (H2S) and volatile organic sulfur compounds (VOSCs) in off-gas mixture from a wastewater treatment plant (WWTP) is difficult due to the occasional inhibitory effects of H2S on VOSC degradation. In this study, a two-stage bio-trickling filter (BTF) system was developed to treat off-gas mixture from a real WWTP facility. At an empty bed retention time of 40 s, removal efficiencies of H2S, methanethiol, dimethyl sulfide, and dimethyl disulfide were 90.1, 88.4, 85.8, and 61.8%, respectively. Furthermore, the effect of lifting load shock on system performance was investigated and results indicated that removal of both H2S and VOSCs was slightly affected. Illumina Miseq sequencing revealed that the microbial community of first-stage BTF contained high abundance of H2S-affinity genera including Acidithiobacillus (51.43%), Metallibacterium (25.35%), and Thionomas (8.08%). Analysis of mechanism demonstrated that first stage of BTF removed 86.1% of H2S, mitigating the suppression on VOSC degradation in second stage of BTF. Overall, the two-stage BTF system, an innovative bioprocess, can simultaneously remove H2S and VOSC.  相似文献   

13.
The discharge characteristics during the degradation of MNZ by DBD were investigated. Increasing the discharge frequency can promote the degradation of MNZ. MNZ removal reaches 99.1% at the initial concentration of 40 ppm within 120 min. Coexisting organic matter inhibits the degradation of MNZ. The energy efficiency of DBD for MNZ removal is higher than other technologies. Degradation of metronidazole (MNZ) which is a representative and stable antibiotic by dielectric barrier discharge (DBD) in an aqueous solution has been studied. Effects of initial MNZ concentration, solution pH and coexisting organics on the degradation were investigated. The results illustrated that increasing the input power and the discharge frequency can improve the removal of MNZ. At low initial concentration, the removal of MNZ can reach up to 99.1%. Acidic and neutral conditions are more favorable for MNZ removal than alkaline condition in the early stage of degradation. However, the difference in MNZ removal between those in acidic or neutral media and that in alkaline one could be neglected with prolonging of the treatment time. Therefore, this method can be applied to MNZ degradation with a wide pH range. Coexisting organic matter in water can attenuate the removal to some extent. This study could provide valuable references for the degradation of nitroimidazole antibiotics by DBD.  相似文献   

14.
The UF membrane fouling by down- and up-flow BAC effluents were compared. Up-flow BAC effluent fouled the membrane faster than down-flow BAC effluent. The combined effects dominated irreversible fouling. The extent of fouling exacerbated by inorganic particles was higher. The TMP, permeate flux, and normalized membrane flux during 21 days of UF of DBAC and UBAC effluents. Fouling during ultrafiltration of down- and up-flow biological activated carbon effluents was investigated to determine the roles of polysaccharides, proteins, and inorganic particles in ultrafiltration membrane fouling. During ultrafiltration of down- flow biological activated carbon effluent, the trans-membrane pressure was≤26 kPa and the permeate flux was steady at 46.7 L?m2?h1. However, during ultrafiltration of up-flow biological activated carbon effluent, the highest trans-membrane pressure was almost 40 kPa and the permeate flux continuously decreased to 30 L?m2?h1. At the end of the filtration period, the normalized membrane fluxes were 0.88 and 0.62 for down- and up-flow biological activated carbon effluents, respectively. The membrane removed the turbidity and polysaccharides content by 47.4% and 30.2% in down- flow biological activated effluent and 82.5% and 22.4% in up-flow biological activated carbon effluent, respectively, but retained few proteins. The retention of polysaccharides was higher on the membrane that filtered the down- flow biological activated effluent compared with that on the membrane that filtered the up-flow biological activated carbon effluent. The polysaccharides on the membranes fouled by up-flow biological activated carbon and down- flow biological activated effluents were spread continuously and clustered, respectively. These demonstrated that the up-flow biological activated carbon effluent fouled the membrane faster. Membrane fouling was associated with a portion of the polysaccharides (not the proteins) and inorganic particles in the feed water. When there was little difference in the polysaccharide concentrations between the feed waters, the fouling extent was exacerbated more by inorganic particles than by polysaccharides.  相似文献   

15.
Linear, interactive and quadratic effects of process parameters were studied. Degradation of Ofloxacin (Ofx) was related with G value of irradiation process. The synergistic effect of H2O2 on lower dose of g-irradiation was established. The process follows pseudo first order with dose constant (d = 0.232 kGy1). The impact of human activities in the past few decades has paved the way for the release of pollutants due to the improper effluent treatment. Recent studies revealed that, Ofloxacin, an antibiotic as one of the major pollutant affecting surface water and ground water. In this study, the radiolytic potential of Ofloxacin was investigated. The effects of pH, dose and concentration of Ofloxacin were analyzed using One Factor At a Time (OFAT) and the interactive effects between the parameters were studied using Face Centered Central Composite Design. The statistically optimised developed model shows 30% degradation at initial antibiotic concentration of 1mM at pH 3.0 and at 2 kGy dose of gamma ray. The process efficiency was evaluated in terms of G value and its correlation with the concentration of antibiotic was also established. The process of degradation was augmented by the addition of H2O2 (1.5 mM). The reaction kinetics for the process was evaluated, the dose rate constant and the rate of degradation for the augmented process was found to be 0.232 kGy-1 and 0.232 mM/kGy, respectively. The degraded metabolites of the radiolytic degradation of Ofloxacin were analyzed through change in pH, reduction in TOC and GC-MS spectrum.  相似文献   

16.
The concentrations of four types of antibiotics in the Yitong River were detected. The concentration of total coliforms in summer was higher than that in spring. There was a seasonal difference in antibiotic resistance of E. coli. The E. coli in the Yitong River was found to have multiple antibiotic resistance. The Yitong River is one of the largest secondary tributaries of the Songhua River. The area where the Yitong River flows is densely populated and contains the livestock and poultry breeding areas of north-east China. These areas introduce a high risk of antibiotic contamination. In this study, the concentrations of four types of typical antibiotics including quinolones, tetracyclines, sulfonamides, and trimethoprim were determined by solid phase extraction-high performance liquid chromatography. The antibiotic resistance of Escherichia coli caused by antibiotic pollution was investigated. The concentration of total coliforms in the Yitong River was detected by the plate counting method. The antibiotic resistance of E. coli to quinolones, tetracyclines, sulfonamides, and trimethoprim was analyzed by the Kirby-Bauer method. The results showed that the concentration of total coliforms in the summer was higher than that in the spring. There was a seasonal difference in the resistance rate of E. coli to antibiotics except trimethoprim. The antibiotic resistance to fluoroquinolones was relatively low. The resistance rate to tetracyclines was higher during the summer. Moreover, resistance to several antibiotics was observed in all sections. This study provides basic data for research on pollution characteristics and prevention of antibiotic exposure in rivers.  相似文献   

17.
The wastewater from industrial area was treated by EC via Fe and Al electrodes. Cu, Ni, Cr and Zn were highly removed at the first minutes, simultaneously. Pseudo-2nd-order was found to be more suitable for kinetics. Adsorption capacities based on kinetic modeling were observed as Cr>Cu>Ni>Zn. The chemical cost in the case of pH adjustment after EC was less as 3.83 $/m3. It is known that wastewater produced by the metal-plating industry contains several heavy metals, which are acidic in nature and therefore toxic for the environment and for living creatures. In particular, heavy metals enter the food chain and accumulate in vital organs and cause serious illness. The precipitation of these metals is mostly achieved by pH adjustment, but as an alternative to this method, the electrocoagulation process has investigated in this study using iron and aluminum electrodes. The effects of the pH adjustment on removal before and after the electrocoagulation process were investigated, and cost analyses were also compared. It was observed that a high proportion of removal was obtained during the first minutes of the electrocoagulation process; thus, the current density did not have a great effect. In addition, the pH adjustment after the electrocoagulation process using iron electrodes, which are 10% more effective than aluminum electrodes, was found to be much more efficient than before the electrocoagulation process. In the process where kinetic modeling was applied, it was observed that the heavy metal removal mechanism was not solely due to the collapse of heavy metals at high pH values, and with this modeling, it was seen that this mechanism involved adsorption by iron and aluminum hydroxides formed during the electrocoagulation process. When comparing the ability of heavy metals to be adsorbed, the sequence was observed to be Cr>Cu>Ni>Zn, respectively.  相似文献   

18.
The eggshell was used to remediate the contaminated soil by heavy metals. The eggshell addition decreased the available state of the heavy metals. The available calcium in the soil increased due to eggshell addition. The efficiency was investigated in different moisture conditions. In this study, effects of water conditions (flooded, wet, or dry) and eggshell dosages (0, 0.1, 1.0, and 10.0 g/kg soil, respectively) on pH variation, content of unavailable state of heavy metals, form of heavy metals, and available nutritious element calcium (Ca) in acid soils contaminated with heavy metals were investigated, respectively. The soil samples were continuously cultivated indoors and analyzed by toxicity characteristic leaching procedure and community bureau of reference (BCR) sequential extraction procedure. The results showed that the addition of eggshell could effectively improve the pH of acid soil and increase it to neutral level. Moreover, the contents of unavailable state of heavy metals Cu, Zn, and Cd increased significantly. Furthermore, when the soil was cultivated under the flooded condition with 1.0 g/kg eggshell, the unavailable state of Cu, Zn, and Cd increased the most, and these heavy metals were transformed into residual state. On the other hand, the amount of available state of Ca increased to 432.19 from 73.34 mg/kg with the addition of 1.0 g/kg eggshell, which indicated that the addition of eggshell dramatically improved the available state of Ca. Therefore, eggshell could ameliorate the soil environment as it led to the decrease of available heavy metals and improvement of fertilization effectively. In a word, this study indicates that the addition of eggshell would be a new potential method for remediation of acid field soils contaminated with heavy metals.  相似文献   

19.
20.
The inhibition ratio sharply increased with the increasing COD. The absorbance of UV-vis at 420 nm showed a linear correlation with the SMA. The molecular structure of EPS has changed when COD was 9585 mg/L. Illumina Miseq sequencing was employed to reveal the microbial composition. The synthesis of 2-butenal, which is a vital raw material for the production of sorbic acid as a food preservative, generates some toxic by-products, so it is urgent to seek better detoxification strategies for the treatment of 2-butenal manufacture wastewater. In this study, batch experiments were carried out to investigate the inhibition effect of wastewater on the methanogenic activity. To understand the wastewater toxicity to anaerobic granular sludge, variations of the specific methanogenic activity (SMA) and extracellular polymeric substance (EPS) constituents at various wastewater CODs were investigated. Ultraviolet-visible (UV-vis) spectra and Fourier transform infrared (FT-IR) spectra were employed to analyze the structure of the EPS. The results showed that the inhibitory ratio of 2-butenal manufacture wastewater was less than 8.4% on the anaerobic granular sludge when the CODs were less than 959 mg/L. However, the inhibitory ratio increased from 36.4% to 93.6% when CODs increased from 2396 mg/L to 9585 mg/L, with the SMA decreasing from 39.1 mL CH4/(gVSS·d) to 3.2 mL CH4/(gVSS·d). The diversity of the microbial community under various CODs was researched by Illumina 16S rRNA Miseq sequencing and the results demonstrated that ProteiniphilumPetrimonas and Syntrophobacter were the dominant bacteria genera in all sample. Regarding archaea, Methanobacterium was the most dominated archaea genera, followed by the Methanosaeta group in all samples. Moreover, the bacterial communities had changed obviously with increasing CODs, which indicated high CODs played a negative impact on the richness and diversity of bacterial community in the sludge samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号