1.
The traditional concept of Aquifer Storage and Recovery (ASR) has been emphasized and extensively applied for water resources conservation in arid and semi-arid regions using groundwater systems as introduced in Pyne's book titled Groundwater Recharge and Wells. This paper extends the ASR concept to an integrated level in which either treated or untreated surface water or reclaimed wastewater is stored in a suitable aquifer through a system of spreading basins, infiltration galleries and recharge wells; and part or all of the stored water is recovered through production wells, dual function recharge wells, or by streams receiving increased discharge from the surrounding recharged aquifer as needed. In this paper, the author uses the El Paso Water Utilities (EPWU) ASR system for injection of reclaimed wastewater into the Hueco Bolson aquifer as an example to address challenges and resolutions faced during the design and operation of an ASR system under a new ASR system definition. This new ASR system concept consists of four subsystems: source water, storage space-aquifer, recharge facilities and recovery facilities. Even though facing challenges, this system has successfully recharged approximately 74.7 million cubic meters (19.7 billion gallons) of reclaimed wastewater into the Hueco Bolson aquifer through 10 recharge wells in the last 18 years. This ASR system has served dual purposes: reuse of reclaimed wastewater to preserve native groundwater, and restoration of groundwater by artificial recharge of reclaimed wastewater into the Hueco Bolson aquifer.  相似文献   

2.
ABSTRACT: Mathematical modeling techniques are used to develop predictive equations for cost of water and waste water treatment processes in developing countries utilizing socioeconomic, environmental, and technological indicators. Predictive equations are developed for each of the three regions (Africa, Asia, and Latin America) for construction, operation, and maintenance costs of slow sand filter, rapid sand filter, stabilization lagoon, aerated lagoon, activated sludge, and trickling filter. Data analysis indicated that cost of water treatment processes is a function of technological indicator (percentage of imported materials), population, and the design capacity. The variables which gave the best correlation for waste water treatment cost were population, design flow, and the percentage of imported waste water disposal materials.  相似文献   

3.
ABSTRACT: The Tucson area is totally dependent on ground water, which is in increasingly short supply due to excessive overdrafts. Tucson area waste water treatment plants discharge material quantities of secondary effluent downstream, which is lost to evapotranspiration and recharge of the ground water basin. The city and the four large mining companies who share the common Santa Cruz basin ground water, recognized the common water supply problem and agreed to fund a feasibility study for mining process use of the effluent to partly alleviate the overdraft of ground water. The study analyzed the projected waste water effluent resources, potential mining company demand for waste water effluent and possible interface of an effluent delivery facility with the proposed Central Arizona Project. The effluent resources were analyzed with respect to potential demand. An optimum alignment was selected. An optimum system was detailed through design schematics, amortized cost and finance requirements, and an implementation schedule. It was concluded that a waste water effluent delivery facility could be implemented which would utilize reclaimed effluent in quantities approximating 35 percent of basin overdraft and which would provide revenue for full cost recovery over a 20 year operation period. The mining companies are studying the internal economic impacts of the project.  相似文献   

4.
ABSTRACT: Data were obtained from drilling and testing of a test injection well for deep underground injection of waste water effluent from the proposed 50-million-gallon-per-day (mgd) South District Regional Wastewater Treatment Plant of the Miami-Dade Water and Sewer Authority, Dade County, Florida. The drilling operation progressed in stages, each stage coverting the strata to be sealed off by the 48-inch, 40-inch, 30-inch, and 20-inch casings, respectively. Total depth of the well is 3,200 feet. The top of the saline, cavernous, dolomitic Boulder Zone was found at 2,790 feet below the surface and is separated from the Floridan aquifer above by approximately 1,100 feet of confining limestone layers. These confining layers were determined, by packer testing, to be very effective. The transmissivity of the Boulder Zone was estimated to be 14 × 106 gallons per day per foot (gpd/ft) from the data obtained from pump out tests. An 8,000-gallon-per-minute (gpm) injection test was conducted to confirm well performance under operating conditions. Based on all of the data obtained, it was concluded that underground injection into the Boulder Zone of secondary waste water effluent from the proposed treatment plant is feasible, both hydraulically and environmentally. A monitoring system was proposed to provide a record of the effects of injection on the subsurface environment.  相似文献   

5.
ABSTRACT: Feasibility of disposing treated sewage in wells sunk into a partially confined coastal limestone aquifer at Waimanalo in the island of Oahu was investigated using an electric analog model. Electric analog modeling was preferred over digital modeling because of ease with which tides could be generated at the ocean boundary in the form of sinusoidal waves. The results of model operation showed that high permeability, low storativity, and the presence of ocean render the Waimanalo aquifer highly suitable for the disposal of waste water in deep wells. Since the quality of water in the aquifer is already unsuitable for municipal, industrial, or agricultural use, waste water injection will not result in any loss of fresh water supply source to the island. It is also believed that the cost of waste water disposal through the aquifer will be considerably less than that through an ocean outfall. During model development it was discovered that electric analog models can help prepare certain graphs which can be useful for aquifer analysis without any further use of the model.  相似文献   

6.
Johnson, R.L., B.R. Clark, M.K. Landon, L.J. Kauffman, and S.M. Eberts, 2011. Modeling the Potential Impact of Seasonal and Inactive Multi‐Aquifer Wells on Contaminant Movement to Public Water‐Supply Wells. Journal of the American Water Resources Association (JAWRA) 47(3):588‐596. DOI: 10.1111/j.1752‐1688.2011.00526.x Abstract: Wells screened across multiple aquifers can provide pathways for the movement of surprisingly large volumes of groundwater to confined aquifers used for public water supply (PWS). Using a simple numerical model, we examine the impact of several pumping scenarios on leakage from an unconfined aquifer to a confined aquifer and conclude that a single inactive multi‐aquifer well can contribute nearly 10% of total PWS well flow over a wide range of pumping rates. This leakage can occur even when the multi‐aquifer well is more than a kilometer from the PWS well. The contribution from multi‐aquifer wells may be greater under conditions where seasonal pumping (e.g., irrigation) creates large, widespread downward hydraulic gradients between aquifers. Under those conditions, water can continue to leak down a multi‐aquifer well from an unconfined aquifer to a confined aquifer even when those multi‐aquifer wells are actively pumped. An important implication is that, if an unconfined aquifer is contaminated, multi‐aquifer wells can increase the vulnerability of a confined‐aquifer PWS well.  相似文献   

7.
Summary Wide Range of human and anthropogenic activities impinges on the urban environment in most cities in Nigeria, to degrade the quality of water resources. Some of these activities (daily discharge of solid and liquid waste, industrial effluent, and physo-chemical weathering processes) are discharged directly on sources of water supply to the populace of Onitsha. Based on this problem, this paper examines the quality of water from hand-dug wells in Onitsha. 15 wells water samples were collected during the month of January, July, and August with the aid of sterilized containers. And sent to the laboratory for analyses, results showed that wells that are located close to dumpsites are more polluted in terms of turbidity, TSS, CaCo2 conductivity salinity acidity, Pb, Fe and bacteriological quality of the well water. Also most of the hand-dug well water qualities are unsafe for human consumption, because they are generally above the WHO maximum acceptable threshold. Since this source of water form one of the major source of water to the inhabitants, there is need for purification proper disposal of waste, public education of the health implication of waste/impure water and other management measures.  相似文献   

8.
ABSTRACT The Cortaro Area is currently the depository for much of the liquid waste from the City of Tucson. In the past, more than one-half of the sewage effluent was used for crop irrigation. However, since 1970 virtually all of the sewage effluent has been percolated in the normally dry Santa Cruz River channel. Nitrate and chloride contents were monitored monthly in water samples from about 20 large-capacity irrigation wells. Contents and seasonal trends for these constituents were closely related to the disposal of sewage effluent. Water quality problems other than nitrate include total dissolved solids, boron, coliform, and lead. High lead contents in the area appear to be a natural phenomenon and the coliform contents are likely related to poor well construction. The other quality problems are primarily due to sewage effluent.  相似文献   

9.
Since 1961, control over water-supply interference problems in the Province of Ontario has been provided under The Ontario Water Resources Commission Act. A section of The Act requires persons taking more than 10,000 imperial gallons per day of water for purposes other than domestic, stock or fire-fighting to have a permit and to take the water in accordance with specified terms and conditions. Construction of some new wells, sewers, and roads to meet the needs of urban development has caused interference with both ground- and surface-water supplies. In cases of serious interference, the Commission has required that steps be taken to restore water supplies or prevent continued interference. Two cases are described where municipalities in the Toronto area restored supplies to overcome serious interference with several private wells and streamflow during testing and operation of a 500-imperial gpm municipal well adjacent to a normally effluent stream, and varying degrees of interference with private wells caused by dewatering at rates up to 2000-imperial gpm for the installation of a trunk sewer.  相似文献   

10.
ABSTRACT: Closely located domestic and public supply wells were sampled using identical sampling procedures to allow comparison of water quality associated with well type. Water samples from 15 pairs of wells with similar screened intervals completed in the central High Plains regional aquifer in parts of Kansas, Oklahoma, and Texas were analyzed for more than 200 water quality constituents. No statistically significant differences were observed between the concentrations of naturally‐derived constituents (major ions, trace elements, and radon) in paired wells. However, differences in water quality between paired wells were observed for selected anthropogenic compounds (pesticides and tritium), in that some public supply wells produced water that was more recently recharged and contained constituents derived from surface activities. The presence of recently recharged water and compounds indicative of anthropogenic activities in some public supply wells was likely due to operational variations (pumping rate and pumping cycles), as demonstrated in a particle tracking simulation. Water containing surface‐derived anthropogenic compounds from near the water table was more quickly drawn to high volume public supply wells (less than five years) than domestic wells (greater than 120 years) with small pumping rates. These findings indicate that water quality samples collected from different well types in the same area are not necessarily directly comparable. Sampling domestic wells provides the best broad‐scale assessment of water quality in this aquifer setting because they are less susceptible to localized contamination from near the water table. However, sampling public supply wells better represents the quality of the used resource because of the population served.  相似文献   

11.
ABSTRACT: The use of artificial recharge in Saskatchewan and the rest of Canada to improve rural community and farmstead domestic water supply has great potential. Approximately 75 percent of the people in rural Saskatchewan and 26 percent of all the people in Canada are dependent on ground water for their domestic water supply. Typically, this water is highly mineralized and is often unpalatable due to odor and taste. A source of readily available, high quality water to eliminate expensive chemical treatment of available water and long distance hauling would be of significant value to rural residents. Storage of high quality water in aquifers by injection through wells has been documented and has been shown to depend on the use of a surface water catchment system to provide the high quality water. Since air entrainment or formation clogging can occur in poorly operated recharge schemes, development of proper design and operation of recharging procedure is required. This can be accomplished by using an injection response computer model and a properly designed injection system. Small scale artificial recharge projects will provide a valuable commodity to rural water users and will promote sustainable and conjunctive use of surface and ground water resources.  相似文献   

12.
With the pressure from industries and municipalities to reduce the waste water treatment costs associated with the permit limits needed to attain the goals of the Clean Water Act, attention has turned ways of introducing flexibility into the regulations without sacrificing the water quality goals. Wisconsin is the first state to have adopted a variety of options from which dischargers may choose when meeting their water quality requirements. These options were developed for the express purpose of minimizing the costs and maximizing the flexibility of the point source water quality regulations while ensuring that permitted discharge would not violate the water quality standards. This paper presents five options that the state has made available to dischargers, as well as one the state did not adopt. The conclusion is that a mix of options can substantially increase the flexibility and reduce the costs of meeting water quality standards on effluent limited streams.  相似文献   

13.
ABSTRACT: Results of computer calculations are presented which predict the pressure response of a closed casing annulus of an injection well to temperature and pressure variations of the injected waste stream. For example, a 3000 ft. disposal well receiving fluid at 100d̀F might cause an increase in annular pressure of some 500 psi. Graphs summarizing these results are included. The results will be of interest to waste injection well operators, inasmuch as they are required to monitor annulus pressure to prove mechanical integrity of their injection wells.  相似文献   

14.
含油污泥深度调堵技术在大庆油田的应用   总被引:3,自引:1,他引:3  
含油污泥调堵技术是将废弃的含油污泥配制成调堵剂,对低压井进行调堵,既可废物利用,又可对低压井进行治理。对配制工艺在室内实验研究的基础上,对大庆油田两口井的含油污泥进行了调堵试验,完成了设计注入量。对调堵剂的配方、配制技术、注入量及注入工艺进行了一系列的现场实践检验。结果表明,含油污泥深度调堵技术不仅能改善注入井吸水剖面,而且为解决油田废弃油泥的环境污染问题提供了新的途径。  相似文献   

15.
ABSTRACT: An application of the receiving water block of the EPA Storm Water management Model (SWMM) is presented to quantify water quality impacts and evaluated control alternatives for a 208 areawide waste water management plan in Volusia Country, Florida. The water quality impact analyses were conducted for dry-and wet-weather conditions to simulate dissolved oxygen (DO), chlorides, total nitrogen (TN), and total phosphorus (TP) in the Halifax Rivers, Florida, a 40-kilometer-long tidal estuary located on the Atlantic coast of Florida near Daytona Beach. Dry-weather analysis was performed using conventional 7-day, 10-year low flow conditions to determine a set of unit transfer coefficients which estimate the pollutant concentration transferred to any point in the estuary from a constant unit discharge of pollutants at the existing waste water treatment plant outfall locations. Wet-weather analysis was performed by continuous simulation of a typical three-month summer wet season in Florida. Three-month cumulative duration curves of DO, TN and TP concentrations were constructed to estimate the relative value of controlling urban runoff of waste water treatment plant effluent on the Halifax River. The three-month continuous simulation indicated that the greatest change in DO, TN, and TP duration curves is possible by abatement of waste water treatment plant pollution.  相似文献   

16.
ABSTRACT: The U.S. Geological Survey (USGS) has compiled a national retrospective data set of analyses of volatile organic compounds (VOCs) in ground water of the United States. The data are from Federal, State, and local nonpoint‐source monitoring programs, collected between 1985–95. This data set is being used to augment data collected by the USGS National Water‐Quality Assessment (NAWQA) Program to ascertain the occurrence of VOCs in ground water nationwide. Eleven attributes of the retrospective data set were evaluated to determine the suitability of the data to augment NAWQA data in answering occurrence questions of varying complexity. These 11 attributes are the VOC analyte list and the associated reporting levels for each VOC, well type, well‐casing material, type of openings in the interval (screened interval or open hole), well depth, depth to the top and bottom of the open interval(s), depth to water level in the well, aquifer type (confined or unconfined), and aquifer lithology. VOCs frequently analyzed included solvents, industrial reagents, and refrigerants, but other VOCs of current interest were not frequently analyzed. About 70 percent of the sampled wells have the type of well documented in the data set, and about 74 percent have well depth documented. However, the data set generally lacks documentation of other characteristics, such as well‐casing material, information about the screened or open interval(s), depth to water level in the well, and aquifer type and lithology. For example, only about 20 percent of the wells include information on depth to water level in the well and only about 14 percent of the wells include information about aquifer type. The three most important enhancements to VOC data collected in nonpoint‐source monitoring programs for use in a national assessment of VOC occurrence in ground water would be an expanded VOC analyte list, recording the reporting level for each analyte for every analysis, and recording key ancillary information about each well. These enhancements would greatly increase the usefulness of VOC data in addressing complex occurrence questions, such as those that seek to explain the reasons for VOC occurrence and nonoccurrence in ground water of the United States.  相似文献   

17.
Excessive nutrient loading (considering nitrogen and phosphorus) is a major ongoing threat to water quality and here we review the impact of nutrient discharges from wastewater treatment plants (WWTPs) to United States (U.S.) freshwater systems. While urban and agricultural land uses are significant nonpoint nutrient contributors, effluent from point sources such as WWTPs can overwhelm receiving waters, effectively dominating hydrological characteristics and regulating instream nutrient processes. Population growth, increased wastewater volumes, and sustainability of critical water resources have all been key factors influencing the extent of wastewater treatment. Reducing nutrient concentrations in wastewater is an important aspect of water quality management because excessive nutrient concentrations often prevent water bodies from meeting designated uses. WWTPs employ numerous physical, chemical, and biological methods to improve effluent water quality but nutrient removal requires advanced treatment and infrastructure that may be economically prohibitive. Therefore, effluent nutrient concentrations vary depending on the particular processes used to treat influent wastewater. Increasingly stringent regulations regarding nutrient concentrations in discharged effluent, along with greater freshwater demand in populous areas, have led to the development of extensive water recycling programs within many U.S. regions. Reuse programs provide an opportunity to reduce or eliminate direct nutrient discharges to receiving waters while allowing for the beneficial use of reclaimed water. However, nutrients in reclaimed water can still be a concern for reuse applications, such as agricultural and landscape irrigation.  相似文献   

18.
ABSTRACT: Churchill County, Nevada, has approximately 23,000 residents, among whom an estimated 13,500 relied on private wells for water supply in 2002. This study examined exposure to arsenic in water supplies among residents with private domestic wells and factors related to householder choice to consume tap water. It compared opinions and concerns about water quality with consumption habits and observed concentrations from tap water samples. The results from 351 households indicated that a majority (75 percent) of respondents consumed tap water and that a minority (38 percent) applied treatment. Approximately 66 percent of those who consumed tap water were exposed to concentrations of arsenic that exceeded 10 ppb. Water consumption was related to application of treatment. Among 98 respondents who were not at all concerned about the health effects of aqueous arsenic, 59 (60 percent) reported consuming tap water with concentrations of arsenic exceeding 10 ppb. Conversely, among 86 respondents who were highly concerned about arsenic, 33 (37 percent) consumed tap water with concentrations of arsenic exceeding 10 ppb. Results from a national sampling effort showed that 620 of 5,304 private wells sampled (11.7 percent) had arsenic concentrations above 10 ppb. The paradox of awareness of arsenic in water supplies coupled with consumption of aqueous arsenic in concentrations greater than 10 ppb may be common in other parts of the nation. Enhanced educational efforts, especially related to tap water sampling and explanations of efficacy of available treatment, may be useful means of reducing exposure through private water supplies.  相似文献   

19.
ABSTRACT: A Geographic Information System (GIS) was used to develop an automated procedure for identifying the primary aquifers supplying ground water to individual wells in eastern Arkansas. As mandated by state law, water-use data are reported by ground-water withdrawers annually to the Arkansas Soil and Water Conservation Commission, and stored in the Arkansas Site-Specific Water-Use Data System provided and supported by the U.S. Geological Survey. Although most withdrawers are able to provide the amount of water withdrawn and the depth of their wells, very few are able to provide the name of the aquifer from which they withdraw water. GIS software was used to develop an automated procedure for identifying the primary aquifers supplying ground water to individual wells in eastern Arkansas. The software was used to generate a spatial representation of the bottom boundary for the Mississippi River Valley alluvial aquifer (the shallowest aquifer) in eastern Arkansas from well log-data collected by the U.S. Geological Survey. The software was then used to determine the depth of the aquifer bottom at reported well locations to ascertain whether the Mississippi River Valley alluvial aquifer or a deeper aquifer was the primary aquifer providing water to each well. The alluvial aquifer was identified as the primary aquifer for about 23,500 wells.  相似文献   

20.
文章分析了目前长庆油田站场生活污水处理工艺存在的问题,对生活污水处理工艺进行了改进,采用膜生物反应器工艺处理生活污水以得到优质的中水,从而回收利用。通过对实际工程进行水质监测,COD、氨氮、浊度的去除效果好于GB 18920-2002《城市污水再生利用城市杂用水水质》中冲厕、绿化等用水要求。通过中水回用,形成"给水→利用→处理→循环利用"的中水回用模式,既节约了新鲜水,又减少了污水排放,保护了油区生态环境。  相似文献   