首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A multimedia sampling of ambient air, wet deposition, surface water, sediment, soil and biota has been performed at Kosetice background observatory in the southern Czech Republic since 1988. An integrated monitoring approach was applied to assess the current state, anthropogenic impacts, and possible future changes of terrestrial and freshwater environments. Average PCB concentrations in the individual matrices calculated from ten years of sampling on multiple sites varied between 2 ng g(-1) in sediment and 7 ng g(-1) in soil or moss. DDT concentrations were lower in moss and needles (2 ng g(-1) and 4 ng g(-1), respectively) than in sediment (11 ng g(-1)) and soil (20 ng g(-1)), while the HCH level was higher in moss and needles (5 ng g(-1) and 6 ng g(-1), respectively) than in soil or sediment (1 ng g(-1) and 2 ng g(-1), respectively). The highest average level of PAHs was found in soil (600 ng g(-1)), while it was lower in needles (230 ng g(-1)), moss (210 ng g(-1)) or sediment (210 ng g(-1)). Time related trends of concentration levels of persistent organic pollutants in all matrices were investigated. Moss and needle trend patterns resembled those of the ambient air, showing a slight concentration decrease of all compounds, except for hexachlorobenzene. The soil, water and sediment concentrations showed a similar decrease of PAHs, PCBs, and HCHs, but there was no clear trend for DDTs and HCB.  相似文献   

2.
The present work provides a multi-residue analytical method for determining a selection of 20 pharmaceuticals from diverse therapeutical classes in hospital effluent wastewater. The method is based on the simultaneous extraction of the target compounds by solid phase extraction (SPE), followed by liquid chromatography-time-of-flight-mass spectrometry (LC-TOF-MS) analysis. Using TOF-MS, accurate mass measurements within 2 ppm error were obtained for most of the pharmaceuticals studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. Validation studies showed that LC-TOF-MS analysis is a valuable new tool for identification and quantification of pharmaceuticals in wastewater. Recoveries, using Oasis HLB cartridges at pH 7, were higher than 75% for all pharmaceuticals, except for ranitidine, 4-methylaminoantipyrine (4-MAA), cefotaxime and omeprazole, which needed specific pH conditions for their extraction. Linearity of response over two orders of magnitude was demonstrated (r > 0.99). Matrix effects resulting in suppression of the response were observed. For most of the compounds ion suppression was less than 39%, except for metronidazole, carbamazepine 10,11-epoxide, naproxen and erythromycin, where the signal suppression was 42%, 59%, 46% and 95%, respectively. A simple and effective approach to minimize or avoid matrix interferences was the 1 : 4 dilution of the SPE extracts. Method detection limits (MDLs) and quantification limits (MQLs) ranged between 4-115 ng l(-1) and 14-384 ng l(-1), respectively. The precision of the method, calculated as relative standard deviation (RSD), ranged from 1.1-19.8% and 1.7-21.7% for intra- and inter-day, respectively. The developed analytical method was applied to the analysis of hospital effluent wastewater during a survey study. 18 of the 20 pharmaceuticals studied were detected at concentration levels of microg l(-1), reaching in some cases concentrations over 100 microg l(-1), and in the case of the analgesic and antipyretic dipyrone metabolite, higher than 1000 microg l(-1).  相似文献   

3.
A method was developed for the determination of benzene in urine. The sample was pumped through the donor channel of a membrane extraction unit with a micro-porous membrane, separating the donor channel from an identical acceptor channel purged with nitrogen. The analyte reached the acceptor channel by diffusion through the membrane and was then swept by the carrier to a solid sorbent tube, where it was trapped. The analyte was subsequently thermally desorbed and analyzed by gas chromatography (GC) with mass selective detection (MS). After optimization, the recovery was close to quantitative, or 95%. Purging the membrane unit with pure water in between the samples eliminated any memory effects. The linearity was good in the concentration range examined (20-4000 ng l(-1)), with a correlation coefficient of 0.9996. The repeatability at 50 ng l(-1) and 400 ng l(-1) was 1.4% and 1.2%, respectively. The limit of detection was 12 ng l(-1) and the limit of quantification 35 ng l(-1). This enables assessment of benzene exposures of occupationally exposed subjects, of smokers and the majority of the general population. The developed method can be easily automated.  相似文献   

4.
建立了土壤和沉积物中8种多溴联苯醚(PBDEs,BDE-28、BDE-47、BDE-99、BDE-100、BDE-153、BDE-154、BDE-183和BDE-209)加速溶剂同时萃取和净化-气相色谱-三重四极杆串联质谱(ASE-GC-MS-MS)的分析方法。通过优化加速溶剂萃取与弗罗里硅土在线净化和串联质谱多反应监测模式的条件,较好地去除基质干扰,并提高了三重四极杆串联质谱定性的准确性及定量的灵敏性。该方法采用改进的色谱柱能同时分析包括高溴代联苯醚BDE-209在内的8种PBDEs,其浓度范围为1~100 ng/mL(BDE-209为10~1 000 ng/mL),线性良好,线性回归系数均大于0.997。方法检出限为0.004~0.1 ng/g,方法回收率为75%~110%,方法精密度为2.4%~15.6%。适于批量处理土壤和沉积物中含有多组分痕量PBDEs的样品。  相似文献   

5.
The development of a high-throughput method for the analysis of 14 endocrine-disrupting substances in environmental solid matrices has been investigated. Selected compounds were: hormones (estrogens and progestogens), parabens and triclocarban. The ultrafast method (15 s per sample) is based on the laser diode thermal desorption-atmospheric pressure chemical ionization (LDTD-APCI) coupled to tandem mass spectrometry (MS/MS). This novel approach was tested and validated in three different solid matrices (municipal sludge cakes, aquatic sediments and agricultural soils) and its performance was evaluated by estimation of extraction recovery, linearity, precision, and detection limits. In contrast to other methods based on LC-MS/MS, a cleanup step is not necessary or minimal for the municipal sludge cake matrix. Extraction recoveries ranged from 80 to 109% for all compounds in all matrix types except for estriol which was 60-75%. The intra- and inter-day precisions, as indicated by % RSD, were ≤ 14% and ≤ 16%, respectively. The method detection limits ranged from 0.7 to 4.0 ng g?1 in sediments and soil matrices and 2.8 to 16.8 ng g?1 for municipal sludge cake samples. The results for real environmental samples collected in different areas of Quebec (Canada) are illustrated.  相似文献   

6.
以鱼肉样品为研究对象,采用超声波法提取鱼肉中的硝基苯类化合物,并通过凝胶色谱进行净化、浓缩,最后用气相色谱定量分析,得到生物样品中硝基苯类化合物的检出限,同时与传统的索氏提取法进行加标回收试验比较。结果表明:用超声波提取鱼肉样品中的硝基苯类化合物方法可行,回收率稳定,并且得到检出限为0.13~2.72 ng/g,加标回收率在60%~78%,RSD在0.04%~3.2%。  相似文献   

7.
Concentrations of six endocrine-disrupting compounds (EDCs), bisphenol A (BPA), estrone (E(1)), 17β-estradiol (E(2)), estriol (E(3)), 17α-ethynylestradiol (EE(2)) and diethylstilbestrol (DES), were assessed in influents, effluents and excess sludge in ten municipal wastewater treatment plants (WWTPs) in the Three Gorges Reservoir (TGR) area, Chongqing, China. Three types of activated sludge treatment processes, oxidation ditch (OD), reversed anaerobic-anoxic-oxic (rA(2)/O) technology and sequential batch reactor (SBR), were used in the surveyed WWTPs. These WWTPs were all combined landfill leachate-sewage treatment plants. All analytes were extracted by solid-phase extraction (SPE) in the dissolved phase and by accelerated solvent-based extraction (ASE) in sludge. Gas chromatography-mass spectrometry (GC-MS) was employed for the analysis of EDCs. Among these EDCs, BPA was the most frequently detected and abundant compound (100.0-10566.7 ng L(-1), 15.5-1210.7 ng L(-1) and 85.0-2470.4 ng g(-1) with respect to the influents, effluents and excess sludge samples). The greatest levels of steroidal estrogens in municipal influents were observed in E(3) which were all >100 ng L(-1), followed by E(1) (42.2-110.7 ng L(-1)) and E(2) (7.4-32.7 ng L(-1)), and in the effluents and sludge were E(1) > E(3) > E(2) which were all <31 ng L(-1) and 105 ng g(-1), respectively. Regarding synthetic estrogens, EE(2) was frequently detected in the influents, occurring below 50 ng L(-1), while DES was not detected at all. A high correlation coefficient was observed between the leachate-sludge ratio and concentrations of influent EDCs, and it was statistically significant (i.e., R > 0.65, P < 0.05), but removal efficiency of the EDCs did not show significant differences with OD, rA(2)/O and SBR processes. Furthermore, modification of treatment technology as well as operational parameters, such as hydraulic retention time (HRT), sludge retention time (SRT) and disinfection process (DP), were recommended to further eliminate the residual EDCs.  相似文献   

8.
The analysis of BTEX and other substituted benzenes in water samples using solid phase microextraction (SPME) and quantification by gas chromatography with flame ionization detection (GC-FID) was validated. The best analytical conditions were obtained using PDMS/DVB/CAR fibre using headspace extraction (HS-SPME) at 50 [degree]C for 20 min without stirring. The linear range for each compound by HS-SPME with GC/FID was defined. The detection limits for these compounds obtained with PDMS/DVB/CAR fibre and GC/FID were: benzene (15 ng L(-1)), toluene (160 ng L(-1)), monochlorobenzene (54 ng L(-1)), ethylbenzene (32 ng L(-1)), m-xylene (56 ng L(-1)), p-xylene (69 ng L(-1)), styrene (35 ng L(-1)), o-xylene (42 ng L(-1)), m-dichlorobenzene (180 ng L(-1)), p-dichlorobenzene (230 ng L(-1)), o-dichlorobenzene (250 ng L(-1)) and trichlorobenzene (260 ng L(-1)). This headspace SPME-GC-FID method was compared with a previously validated method of analysis using closed-loop-stripping analysis (CLSA). The headspace SPME-GC-FID method is suitable for monitoring the production and distribution of potable water and was used, in field trials, for the analysis of samples from main intakes of water (surface or underground) and from the water supply system of a large area (Lisbon and neighbouring municipalities).  相似文献   

9.
ASE萃取-SPE净化-HPLC法测定土壤中多环芳烃   总被引:6,自引:0,他引:6  
建立了加速溶剂萃取-固相萃取净化-高效液相色谱测定土壤中16种多环芳烃的方法,优化了试验条件.方法线性关系良好,16种多环芳烃的检出限在0.412 ng/g~3.974 ng/g之间,空白加标试验的相对标准偏差在1.2%~12.7%之间,基质加标回收率在60.4%~126%之间.实际样品的测定结果表明该方法分离效果好,能够满足土壤分析的要求.  相似文献   

10.
Nonylphenol (NP) is a representative environmental endocrine-disrupting chemical and persistent toxic pollutant. Previous studies have shown that the average concentration of NP in environmental waters was approximately tens to hundreds of ng L(-1) and it could even reach up to tens of μg L(-1). A simple, fast and accurate method employing a novel solid-phase extraction element named "Magic Chemisorber" (MC) followed by high-performance liquid chromatography (HPLC) using a fluorescence detector (FLD) was used for detecting NP. The most important parameters that affect the extraction process, including extraction time, desorption time, desorption solvent and repeatability, were optimized. The MC-HPLC method showed good linearity with concentrations of NP from 10 to 200 μg L(-1), a correlation coefficient of 0.9995 and the limit of detection (LOD) and limit of quantification (LOQ) of this method was 0.44 and 1.47 μg L(-1), respectively. Compared to commercial polydimethylsiloxane (PDMS) glass fiber, MC had both higher capacity and recovery and it could be used repeatedly. Using the MC-HPLC method we found that the concentration of NP in river water from Hangzhou city ranged from 8.54 ± 1.23 μg L(-1) (Qiantang River) to 65.77 ± 3.69 μg L(-1) (Tiesha River), which was similar to that of international regions heavily polluted with NP and higher than that of Bohai Bay, the Yellow River and the Pearl River Delta in China. This level of NP pollution is possibly related to the rapid development of the textile, printing and paper industries of Zhejiang province.  相似文献   

11.
Hospital effluent and connected waste water treatment plant (WWTP) influent and effluent were sampled daily to determine the levels and inter-day variations of three naturally occurring steroid estrogens: estrone, 17β-estradiol, estriol, and synthetic 17α-ethinylestradiol. After solid phase extraction, interferences were removed with a silica gel clean-up step and the samples analysed using gas chromatography with mass selective detection (GC-MSD). The determined inter-day concentrations in hospital effluent were between 8.6 to 31.3 ng L(-1) for estrone, 相似文献   

12.
An optimized extraction and clean-up method for the analysis of chlortetracycline, doxycycline, oxytetracycline, and tetracycline antibiotics in soil is presented in this work. Soil extraction using different solvents was performed, but the use of a 50 : 50 (v/v) methanol : acetate buffer (pH 8) solvent mixture in a pressurized liquid extraction (PLE) system proved to give the best extraction efficiency and reproducibility. The effect of soil composition on the PLE extraction efficiency was also examined, and results indicated that recovery data for one soil is not necessarily consistent with other soil types containing different compositions of clay and organic matter content. The percent recoveries of the optimized PLE method varied between the soils and ranged from 22-99%, depending on soil type, and more specifically clay content. In addition, the extent of ionization suppression caused by co-extracted humic acids was examined in an ion trap mass spectrometer (MS), and a single quadrupole MS. It was found that under positive electrospray ionization, the single quadrupole MS was less susceptible to ionization suppression than the ion trap MS. Therefore, various sample clean-up procedures were evaluated to selectively reduce the amount of co-extracted humic acids in the soil extracts. The most effective clean-up was obtained from the use of StrataX sorbent in combination with a strong anion exchange cartridge.  相似文献   

13.
The use of a large volume polyurethane foam (PUF) sampler was validated for rapid extraction of persistent organic pollutants (POPs), such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), in raw water and treated water from drinking water plants. To validate the recovery of target compounds in the sampling process, a (37)Cl-labeled standard was spiked into the 1st PUF plug prior to filtration. An accelerated solvent extraction method, as a pressurized liquid extractor (PLE), was optimized to extract the PUF plug. For sample preparation, tandem column chromatography (TCC) clean-up was used for rapid analysis. The recoveries of labeled compounds in the analytical method were 80-110% (n = 9). The optimized PUF-PLE-TCC method was applied in the analysis of raw water and treated potable water from seven drinking water plants in South Korea. The sample volume used was between 18 and 102 L for raw water at a flow rate of 0.4-2 L min(-1), 95 and 107 L for treated water at a flow rate of 1.5-2.2 L min(-1). Limit of quantitation (LOQ) was a function of sample volume and it decreased with increasing sample volume. The LOQ of PCDD/Fs in raw waters analyzed by this method was 3-11 times lower than that described using large-size disk-type solid phase extraction (SPE) method. The LOQ of PCDD/F congeners in raw water and treated water were 0.022-3.9 ng L(-1) and 0.018-0.74 ng L(-1), respectively. Octachlorinated dibenzo-p-dioxin (OCDD) was found in some raw water samples, while their concentrations were well below the tentative criterion set by the Japanese Environmental Ministry for drinking water. OCDD was below the LOQ in the treated drinking water.  相似文献   

14.
Antifouling biocides are used to prevent the settlement and growth of organisms on submerged surfaces. Irgarol 1051 is currently among the most widely used organic booster biocides worldwide. This study reports Irgarol 1051, its major metabolite M1 (aka GS26575), and diuron concentrations found in selected California marinas. Seasonal water samples (n = 46) were collected during the summer and fall of 2006 from eleven marinas throughout Southern and Northern California. The samples were extracted using solid phase extraction and analysed utilizing liquid chromatography tandem mass spectrometry (LC-MS-MS) with electrospray ionization. All three compounds were detected in all samples, representing a 100% frequency of occurrence and indicating widespread use around the sampled marinas. Irgarol concentrations ranged from 12 to 712 ng L(-1) (average 102 ng L(-1)), M1 concentrations were 1-217 ng L(-1) (average 31 ng L(-1)), and diuron concentrations were 5-27 ng L(-1) (average 13 ng L(-1)). In general, concentrations of both Irgarol (15-712 ng L(-1)) and M1 (1-217 ng L(-1)) were greater in samples collected during the summer, corresponding to the peak of the boating season. The detected diuron concentrations in most cases were greater for fall samples (7-27 ng L(-1)), and probably represented a combination of non-agricultural (rights of way) and agricultural applications of diuron in California. The maximum Irgarol concentration detected in California marinas in summer 2006 (712 ng L(-1)) was five times greater than the Irgarol concentration suggested as the plant toxicity benchmark (136 ng L(-1)). Twenty three percent of samples from California marinas in this study exceeded this benchmark, suggesting that detected Irgarol concentrations may be high enough to cause changes in phytoplankton communities in the sampled marinas.  相似文献   

15.
建立了废酸油渣中16种多环芳烃超声萃取、Florisil萃取柱净化、气相色谱-质谱测定的方法.笔者对提取方式、提取剂类型和体积、提取时间和次数、净化方式等进行研究,采用无水硫酸钠分散,二氯甲烷作为提取剂超声40 min,提取液经纯水清洗、离心后取适量有机相经过3 g Florisil萃取柱净化,采用气相色谱-质谱选择离...  相似文献   

16.
The determination of mercury in crude oil and petroleum products is particularly difficult due to the volatile nature of both mercury and the matrix, which may lead to significant loss of the analyte. A simple extraction method for total mercury has been developed to determine total mercury in crude oil using cold vapor atomic fluorescence spectrometry. The homogenized crude oil sample was diluted to 5, 10, and 20 % (w/w) in toluene. The diluted crude oil samples were spiked with 10 and 40 μg/kg (w/w). The samples were extracted using an oxidant/acid solution, BrCl/HCl. The mercury was extracted into the aqueous phase; the ionic mercury was then reduced to volatile elemental mercury (Hg0) by stannous chloride (SnCl2). The mercury vapor was detected by Merlin cold vapor atomic fluorescence spectrometry at a 253.7-nm wavelength. The average recoveries for mercury in spiked diluted crude oil (10 and 40 μg/kg, w/w) were between 96 and 103 %, respectively, in 5 and 10 % spiked diluted crude oil. Whereas, low recoveries (<50 %) were recorded in 20 % diluted spiked crude oil. The method detection limit was calculated as t (0.01)(n ? 1)?×?SD where t is the student's value for 99 % confidence level and standard deviation estimate with n???1 degrees of freedom. The method detection limit was found to be 0.38 μg/kg based on 5 g of diluted crude oil sample. The method is sensitive enough to determine low levels of mercury in crude oil.  相似文献   

17.
In this paper, improvements obtained by using focused microwaves for extraction, in the analysis of polycyclic aromatic hydrocarbons (PAHs) adsorbed on particulate matter, are discussed. The method was tested on the following PAHs, which are considered to be among the most harmful with regard to carcinogenicity: benzo[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene. The extraction of PAHs and concentration of the sample can be performed in 3 h with a recovery of at least 70% and a maximum standard deviation of 4%. These steps are followed by clean-up on a SPE (solid-phase extraction) cartridge and analysis by GC-MS. Real samples collected in the urban area of Bari were analysed according to the proposed procedure.  相似文献   

18.
基于EPA1694方法,应用超声波萃取-高效液相色谱-串联质谱技术,建立了沉积物中对乙酰氨基酚、林可霉素、甲氧苄啶、咖啡因、阿奇霉素、磺胺甲唑、泰乐菌素、地尔硫卓、卡马西平及氟西汀等10种药物和个人护理品(PPCPs)的分析检测方法。样品经超声萃取、离心和SAX阴离子交换柱净化,以高效液相色谱-串联质谱仪多反应监测(MRM)模式进行离子定性、定量分析。10种药物加标回收率实验结果表明:添加低浓度样品20 ng/g,回收率为61.1%~128.5%,相对标准偏差(RSD)为1.7%~17.5%(n=5);添加高浓度样品400 ng/g,回收率为66.4%~126.7%,RSD为2.3%~18.0%(n=5),最低检测限为0.12~4.46 ng/g。该方法具有检测限低和回收率高的特点,并经实际样品验证发现,该方法适用于检测沉积物中10种PPCPs化合物。  相似文献   

19.
建立了生物介质内22种多溴联苯(PBBs)和27种多溴联苯醚(PBDEs)的净化和分析方法。通过分析不同时间段凝胶渗透色谱(GPC)洗脱液中49种化合物含量,得出不同化合物凝胶色谱洗脱曲线。样品经过凝胶渗透色谱-混合硅胶柱净化后,再使用GC-(NCI)/MS对样品进行检测。实验结果表明,PBBs和PBDEs检出限分别为0.02~0.88 pg/g和0.01~74.00 pg/g。对实验过程进行验证发现,样品不同浓度加标回收率为80%~120%,相对标准偏差小于20%。该方法具有良好的净化效果、准确度和精密度,拥有良好的线性范围及检出限,满足生物介质中溴代阻燃剂的检测分析实际要求。  相似文献   

20.
The occurrence and removal of eight endocrine disrupting compounds (EDCs), including estrone (E(1)), 17β-estradiol (E(2)), estriol (E(3)), 17α-ethinylestradiol (EE(2)), diethylstilbestrol (DES), bisphenol A (BPA), nonylphenol (NP) and octylphenol (OP), and their estrogenicities were investigated in a sewage treatment plant in Harbin city, China. The EDCs were extracted from wastewater samples by solid phase extraction (SPE) method and analyzed with gas chromatography coupled with mass spectrometry (GC-MS). The average concentrations in the influents and effluents ranged from 6.3 (EE(2)) to 1725.8 ng L(-1) (NP) and from 相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号