首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Gas chromatography-low resolution mass spectrometry was used to quantitate PCDD and PCDF emitted from an urban incinerator. The amounts were determinated in 17 samples collected over 9 months. Wide variability in the different sample concentrations, ranging from 2.3 mg/h to 348 mg/h for PCDD and from 3.9 mg/h to 324 mg/h for the PCDF, was observed.  相似文献   

2.
Weber R  Sakurai T  Ueno S  Nishino J 《Chemosphere》2002,49(2):127-134
The correlation of PCDD/PCDF levels with the CO emissions in a full-scale municipal waste incinerator was assessed during a four-week measurement effort. PCDD/PCDF concentrations in fly ashes-containing more than 99% of the total PCDD/PCDF burden of the fluidized bed incinerator (FBI)-were measured and compared with the emitted CO concentrations. The CO concentration during the sampling time showed no significant correlation to the PCDD/ PCDF amount in fly ash (R2 = 0.078). However, a comparison of the time integrated CO concentration several hours before sampling lead to a correlation with the PCDD/PCDF burden. Maximum correlation was found for the time integrated CO values of 3 and 4 h before sampling (R2 = 0.467 and R2 = 0.457 respectively). This indicates a memory effect in the high temperature cooling section of several hours. Possible mechanisms leading to the memory effect are discussed. The correlation of PCDD/PCDF with CO concentration demonstrate that the combustion conditions play an important role for PCDD/PCDF formation in FBIs. However the variability in the correlation of CO to PCDD/PCDF levels show that other factors have a significant influence on PCDD/PCDF formation.  相似文献   

3.
In 1997, the Polychlorinated dibenzo-para-dioxin (PCDD)/Polychlorinated dibenzofuran (PCDF) concentrations in dairy products in Germany and other European countries increased. The PCDD/PCDF source was contaminated lime used in Brazilian citrus pulp pellets. The contaminated lime was mined from an industrial dump site. However, the detailed origin of the PCDD/PCDFs in the lime was not revealed. This paper investigates the contamination origin and describes the link between lime milk from the dumpsite of a chlorine/organochlorine industry and the contaminated lime. The contaminated lime stem from mining at the corporate landfill of Solvay Indupa in Sao Paulo. The landfill was used for 40 years for deposition of production residues and closed in 1996. The factory operated/operates at least two processes with potentially high PCDD/PCDFs releases namely the oxychlorination process for production of ethylene dichloride (EDC) and the chlor-alkali process. The main landfilled waste was lime milk (1.4 million tons) from the vinyl chloride monomer production (via the acetylene process) along with residues from other processes. The PCDD/PCDF fingerprint revealed that most samples from the chemical landfill showed an EDC PCDD/PCDF pattern with a characteristic octachlorodibenzofuran dominance. The PCDD/PCDF pattern of a Rio Grande sediment samples downstream the facility showed a chlor-alkali pattern with a minor impact of the EDC pattern. The case highlights that PCDD/PCDF- and persistent organic pollutants-contaminated sites need to be identified in a comprehensive manner as required by the Stockholm Convention (article 6) and controlled for their impact on the environment and human health. Landfill mining and reuse of materials from contaminated deposits should be prohibited.  相似文献   

4.
Polychlorinated dibenzo-p-dioxins (PCDD), dibenzofurans (PCDF) and non-ortho substituted biphenyls (PCB, CB) were determined in 6 polar bear milk samples from Svalbard (Norway). For these compounds, no data for polar bears have been reported before from this region. Most of the PCDD/PCDF congeners were found at detectable levels. Concentrations expressed as 2,3,7,8-TCDD equivalents (Nordic model) were in the order of 1–3 pg/g−1 fat (0.2–1.6 pg ml−1 milk) which is comparable with ringed and harp seal blubber from the same region. On whole milk basis, concentrations were similar to those found in human milk. An estimation of the daily uptake via milk showed that the intake is lower for polar bears compared to humans. As in human milk, relatively high levels of OCDD were found in some polar bear milk samples. The PCDD/PCDF congener pattern in the milk was different to that found in polar bear fat from the Canadian Arctic. Non-ortho substituted PCB levels in polar bear milk were similar to those found in polar bear fat from the Canadian North. However, CB 77 or 169 dominated in the milk while CB 126 was the most abundant congener in fat. PCDD/PCDF levels expressed as 2,3,7,8-TE were highly correlated with the fat content of the milk. No correlation between CB and PCDD/PCDF concentrations was found. Some data indicate that PCDD/PCDF concentrations in polar bear milk decrease with increasing time after delivery.  相似文献   

5.
Ryu JY  Choi KC  Mulholland JA 《Chemosphere》2006,65(9):1526-1536
Polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) byproducts can be formed in combustion systems by a variety of mechanisms. While total PCDD/F emissions and, to a lesser extent, homologue distributions from incinerators have been found to vary widely depending on combustion conditions, PCDD/F isomer distributions do not. Formation mechanisms can be grouped into two general categories: condensation of precursors, such as chlorinated phenols, and formation from particulate carbon, termed de novo synthesis. In addition to these mechanisms, chlorination and dechlorination reactions may affect isomer patterns. In this work, isomer patterns from field and laboratory municipal waste combustion samples are compared with computed thermodynamic distributions and those from the following experimental investigations: both gas-phase and metal-catalyzed condensation of chlorinated phenols, chlorination of dibenzo-p-dioxin and dibenzofuran, and dechlorination of octachlorodibenzo-p-dioxin and octachlorodibenzofuran. PCDD/F isomer patterns produced by different formation mechanisms in controlled experiments are distinct and robust, largely unaffected by combustion conditions. PCDD isomer patterns from municipal waste combustion are most similar to those produced by CuCl(2)-catalyzed phenol condensation from 10 chlorinated phenols. PCDF isomer patterns are most similar to those produced by chlorination and dechlorination.  相似文献   

6.
Leclerc D  Duo WL  Vessey M 《Chemosphere》2006,63(4):676-689
This paper discusses the effects of combustion conditions on PCDD/PCDF emissions from pulp and paper power boilers burning salt-laden wood waste. We found no correlation between PCDD/PCDF emissions and carbon monoxide emissions. A good correlation was, however, observed between PCDD/PCDF emissions and the concentration of stack polynuclear aromatic hydrocarbons (PAHs) in the absence of TDF addition. Thus, poor combustion conditions responsible for the formation of products of incomplete combustion (PICs), such as PAHs and PCDD/PCDF precursors, increase PCDD/PCDF emissions. PAH concentrations increased with higher boiler load and/or low oxygen concentrations at the boiler exit, probably because of lower available residence times and insufficient excess air. Our findings are consistent with the current understanding that high ash carbon content generally favours heterogeneous reactions leading to either de novo synthesis of PCDD/PCDFs or their direct formation from precursors. We also found that, in grate-fired boilers, a linear increase in the grate/lower furnace temperature produces an exponential decrease in PCDD/PCDF emissions. Although the extent of this effect appears to be mill-specific, particularly at low temperatures, the results indicate that increasing the combustion temperature may decrease PCDD/PCDF emissions. It must be noted, however, that there are other variables, such as elevated ESP and stack temperatures, a high hog salt content, the presence of large amounts of PICs and a high Cl/S ratio, which contribute to higher PCDD/PCDFs emissions. Therefore, higher combustion temperatures, by themselves, will not necessarily result in low PCDD/PCDFs emissions.  相似文献   

7.
The concentrations, compositional profiles, and possible sources of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) in water column and surface sediment samples from the lower reaches of the Yangtze River were investigated, and the potential risks posed by these chemicals were evaluated. Concentrations of the 17 2,3,7,8-substituted PCDD/PCDF in the water and sediment samples ranged from 0.45 to 10.0 pg TEQ/L (mean 2.34 pg TEQ/L) and from 0.31 to 51 pg TEQ/g dw (mean 5.25 pg TEQ/g dw), respectively. Water and sediments from the Nanjing–Nantong sections of the Yangtze River were found to have elevated PCDD/PCDF levels, and the PCDD/PCDF TEQ concentrations in 13 sediment samples exceeded the probable effect levels (PEL), above which adverse biological effects are likely. Multivariate statistical analysis indicated that the principal PCDD/PCDF contamination source for the water and sediment was the production and use of pentachlorophenol (PCP) or sodium pentachlorophenate (PCP-Na). PCDD/PCDF concentrations were stable over time near the Yangtze River Estuary but had increased sharply in recent decades in the Nanjing–Nantong section, which will have been related to the growth in industrial activities and other anthropogenic PCDD/PCDF sources. Total organic carbon (TOC) and PCDD/PCDF concentrations correlated significantly (R?=?0.474, P?<?0.01), suggesting that TOC plays an important role in the transport and re-distribution of PCDD/PCDF in the Yangtze River basin.  相似文献   

8.
Paddy soils and sediments from the Yoneshirogawa, Omonogawa, and Koyoshigawa River Basins in Akita were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The levels and compositions in those samples including soils from non-agricultural areas (non-agricultural soils) were investigated using isomer-specific analysis to determine characteristic sources. The PCDD/PCDF compositions in the samples were compared with respect to possible sources. The PCDD/PCDF concentrations in paddy soils were much higher than those in the non-agricultural soils and much higher than those found in other parts of Japan. Although PCDD/PCDFs were ubiquitous in sediments from river sources to mouths of the respective river basins, those concentrations were much lower than those from paddy soils and non-agricultural soils, and from other parts of Japan. Comparison of PCDD/PCDF homologues and isomer compositions for samples indicated that compositions of paddy soils and sediments, except for those from river sources, had similar characteristics to PCDD/PCDFs originating from impurities in herbicides, 2,4,6-trichlorophenyl 4-nitrophenyl ether (CNP) and pentachlorophenol (PCP), and that compositions of river-source sediments and non-agricultural soils resembled those of atmospheric depositions. Results of statistical analyses suggest that PCDD/PCDF contamination of paddy soils and sediments is attributable mainly to three sources: CNP, PCP, and atmospheric deposition. Results of this study also demonstrate that CNP and PCP are not only important contaminants of local areas of Japan, but that they exist throughout Akita, in northern Japan. We therefore conclude that PCDD/PCDF pollution caused by those compounds has a widespread influence on paddy soils and river sediments in Japan.  相似文献   

9.
On-line detectable indicator parameters in the flue gas of municipal solid waste incinerators (MSWI) such as chlorinated benzenes (PCBz) are well known surrogate compounds for gas-phase PCDD/PCDF concentration. In the here presented work derivation of indicators is broadened to the detection of fly and boiler ash fractions with increased PCDD/PCDF content. Subsequently these fractions could be subject to further treatment such as recirculation in the combustion chamber to destroy their PCDD/PCDF and other organic pollutants' content. Aim of this work was to detect suitable on-line detectable indicator parameters in the gas phase, which are well correlated to PCDD/PCDF concentration in the solid residues. For this, solid residues and gas-phase samples were taken at three MSWI plants in Bavaria. Analysis of the ash content from different plants yielded a broad variation range of PCDD/PCDF concentrations especially after disturbed combustion conditions. Even during normal operation conditions significantly increased PCDD/PCDF concentrations may occur after unanticipated disturbances. Statistical evaluation of gas phase and ash measurements was carried out by means of principal component analysis, uni- and multivariate correlation analysis. Surprisingly, well known indicators for gas-phase PCDD/PCDF concentration such as polychlorinated benzenes and phenols proved to be insufficiently correlated to PCDD/PCDF content of the solid residues. Moreover, no single parameter alone was found appropriate to describe the PCDD/PCDF content of fly and boiler ashes. On the other hand, multivariate fitting of three or four parameters yielded convenient correlation coefficients of at least r=0.8 for every investigated case. Thereby, comprehension of plant operation parameters such as temperatures and air flow alongside concentrations of inorganic compounds in the gas phase (HCl, CO, SO2, NOx) gave the best results. However, the suitable set of parameters suited best for estimation of PCDD/PCDF concentration in solid residues has to be derived anew for each individual plant and type of ash.  相似文献   

10.
PCDD and PCDF were found in urban air particulates from St. Louis and Washington, D.C., and in sediments from the Great Lakes and Siskiwit Lake, Isle Royale. The similarity between the PCDD and PCDF found in air particulates and sediment samples and the presence of PCDD and PCDF in sediment from Siskiwit Lake (a location which can receive only atmospheric inputs) suggest that these compounds are emitted to the atmosphere from combustion sources. The historical input of PCDD and PCDF to dated sediment cores shows a strong increase since 1940, and this suggests that the incineration of chlorinated organic compounds is an important source of PCDD and PCDF to the environment.  相似文献   

11.
α-HCH, β-HCH, and γ-HCH (lindane) were listed as persistent organic pollutants in the Stockholm Convention. Therefore, they need to be globally addressed including the wastes remaining from historic use and production. While at most lindane production sites the unintentionally produced 85 % HCH waste isomers have been deposited, at a former pesticide factory in Hamburg-Moorfleet HCH waste isomers have been recycled from 1953 to 1984 by thermal decomposition to chlorobenzenes and resulted in high polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran (PCDD/PCDF)-contaminated residues. The management of the PCDD/PCDF-contaminated waste from the former pesticide factory in Hamburg has been assessed and quantified. Based on past accredited PCDD/PCDF measurements, the registered 3,700 tonnes of disposed thermal HCH decomposition residue contained 333 to 854 kg of PCDD/PCDF toxicity equivalent (I-TEQ) in 53–102 tonnes total sum of PCDD/PCDF. The wastes have been deposited together with other wastes in landfills in Hamburg and other parts of Germany. For the Georgswerder landfill (Hamburg), where approximately 50 % of the PCDD/PCDF is disposed, current and previous situation and remediation activities are described. While PCDD/PCDF leaching from the landfill is controlled and incinerated, more water soluble organochlorines (vinyl chloride, cis-1,2-dichlorethene, chlorobenzenes) and benzene remain as a challenge for groundwater management. A comprehensive aftercare program has been established and will need to be operated by future generations including renewal of containment systems. Former lindane/HCH productions need—in addition to HCH deposits—to be assessed for possible recycling practice of HCH and related PCDD/PCDF-containing deposits. This could systematically be addressed within the Stockholm Convention implementation.  相似文献   

12.
When in the vicinity of a metal reclamation plant in Tyrol, Austria, increased PCDD/PCDF levels were found in soil and spruce needles, the extent of grass contamination as well as the PCDD/PCDF content in milk of cows fed with hay from this area was determined. The milk samples showed a significant increase in PCDD/PCDF levels compared to control samples. In a blood sample of a farmer a significant increase in PCDD/PCDF levels was found. Correlations in PCDD/PCDF levels between soil, spruce needles, grass, cow's milk and human blood will be presented.  相似文献   

13.
Cunliffe AM  Williams PT 《Chemosphere》2007,68(9):1723-1732
The influence of temperature on the levels of PCDD and PCDF remaining in, and desorbed from, a municipal solid waste incinerator flyash was investigated by heating the ash to between 200 and 400 degrees C under a simulated flue gas for four days reaction time. Considerable desorption of PCDD/PCDF from the flyash was seen at 275 degrees C and above. Maximum desorption occurred at 350 degrees C, with the equivalent of nearly eight times the total PCDD/PCDF concentration of the original flyash being lost to the vapour phase per unit mass of initial flyash. The I-TEQ value of the desorbed PCDD/PCDF was considerable, being over fourteen times that of the original flyash at 325 degrees C. The results indicate that formation of PCDD/PCDF on flyash deposits in the post-combustion plant of incinerators can result in the release of significant amounts of PCDD/PCDF to the flue gas stream.  相似文献   

14.
C. Cuiu  R. Halman  K. Li  R.S. Thomas  R.C. Lao 《Chemosphere》1986,15(9-12):1091-1098
Sample extracts from each section of a blank stack sampling train are portioned into two fractions, one to be used for PCDD/PCDF and PCB/CB analysis and the other for PAH/CP. The results of recovery studies for spiked compounds are presented. Developed protocols will be applied to future stack sampling programs and other environmental monitorings.  相似文献   

15.
Cunliffe AM  Williams PT 《Chemosphere》2007,66(6):1146-1152
A municipal solid waste incinerator flyash was heated to between 200 and 400 degrees C under nitrogen in a bench-scale, static bed reactor for 4 days soak time. The influence of temperature on the levels of PCDD and PCDF remaining in and desorbed from the ash were investigated using GC-MS/MS. PCDD and especially PCDF formation was seen on the flyash between 225 and 300 degrees C. Large increases in the I-TEQ of the treated ash relative to the increase in its overall PCDD/PCDF content indicated that the formation of 2378-substituted congeners was favoured over that of other substitution patterns. In the absence of a source of gaseous oxygen, formation was mainly attributed to de novo reactions involving solid phase oxygen. Dechlorination of the PCDD/PCDF in flyash became increasingly important above 275 degrees C. Maximum desorption was seen at 325 degrees C, with the equivalent of 35 wt% of the PCDD/F in the original flyash being recovered from the exhaust traps at this temperature. The desorbed species were mainly M(1)CDD/CDDF-T(3)CDD/CDDF resulting from dechlorination of higher chlorinated PCDD/PCDF, with consequently low I-TEQ values.  相似文献   

16.
H.Y. Tong  F.W. Karasek 《Chemosphere》1986,15(9-12):1219-1224
Flyash samples were collected from the electrostatic precipitators of seven municipal refuse incinerators of four different countries. Analytical results of PCDD and PCDF in these samples shows a very similar iosmer distribution pattern for all PCDD/PCDF although concentrations of PCDD and PCDF vary. These results imply that PCDD/PCDF were formed through the same mechanism in those incinerators regardless of garbage composition or incinerator design.  相似文献   

17.
Thirty-one samples of baked-salt products used in commercial food additives were analyzed for the presence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Dioxins were highly detected in 12 samples of baked salts. The amount of dioxins found in the samples ranged from 12.47 pg/g to 406.56 pg/g (0.71 pg TEQ/g to 23.51 pg TEQ/g, respectively). The most abundant congeners, as TEQ values, were 2,3,4,7,8-PeCDF; 1,2,3,7,8-PeCDF; and 1,2,3,4,7,8-HxCDF in PCDF congeners and 1,2,3,7,8-PeCDD; 1,2,3,6,7,8-HxCDD; and 1,2,3,7,8,9-HxCDD in PCDD congeners. Meanwhile, PCDDs/PCDFs were analyzed in high-temperature-treated samples of natural sea salt alone and natural sea salt to which di-(2-ethylhexyl)phthalate (DEHP) had been added. In the former case, PCDD/PCDF formation was most evident at temperatures near 450 degrees C, the total amount of dioxins was 90.07 pg/g (6.07 pg TEQ/g), and PCDD congeners comprised less than 50% of the total PCDDs/PCDFs. However, when the latter samples were heated, the total PCDD/PCDF concentration was 512.30 pg/g (21.53 pg TEQ/g), with PCDD congeners comprising over 87% of the total PCDDs/PCDFs.  相似文献   

18.
Analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) has been performed using gas chromatography mass spectrometry (GC-MS). Analysis of the most toxic isomers, in particular, 2,3,7,8-substituted PCDD/PCDF in the presence of other isomers requires a special isomer specific capillary column or high performance liquid chromatography (HPLC) fractionation prior to GC-MS analysis. Commercially available long (>50 m) polar columns can separate 2,3,7,8-TCDD from other tetra isomers. However, those columns are not satisfactory for the analyses of total PCDD/PCDF in the environmental samples. Gas chromatography -high resolution mass spectrometry (GC-HRMS) and GC-MS/MS techniques are not helpful in the analysis of 2,3,7,8-TCDD unless it is separated from the other tetra isomers. The analysis of 2,3,7,8-TCDD and total PCDD and PCDF in a single GC-MS run can ease the laborious techniques presently used. In this study we have developed a new stationary phase for the GC capillary column. The capillary column developed using this new stationary phase showed unsurpassed selectivity for the separation of 2,3,7,8-TCDD from other tetra isomers. There are several advantages of the newly developed GC capillary column.  相似文献   

19.
Cunliffe AM  Williams PT 《Chemosphere》2007,66(10):1929-1938
The influence of temperature on the PCDD and PCDF isomer profiles of a municipal waste incinerator flyash and the PCDD/PCDF desorbed from the ash under an inert atmosphere was investigated using a bench-scale reactor. Exposure to temperatures of 250 degrees C and above resulted in significant changes in the distribution of isomers within most dioxin and furan congener groups. The PCDD content tended to become more evenly distributed across the range of isomers than was the case for the raw flyash, while the PCDF content became concentrated across a relatively lower number of isomers. In most cases the desorbed PCDD/PCDF were mainly mono- to tri-chlorinated, and hence had a relatively low I-TEQ value. The isomer profiles of the desorbed species were also influenced by temperature. There were some significant differences between the PCDF isomer profiles of the desorbed species and those of the treated flyashes under the same conditions, but no clear differences between the PCDD isomer profiles.  相似文献   

20.
Background, Aims and Scope The Rocky Mountain Arsenal (RMA) is a US Army facility located northeast of Denver, Colorado that has been listed on the National Priorities List (NPL). It is currently being re-mediated under the authority of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) and the Superfund Amendments and Reauthorization Act of 1986 (SARA). As part of the remediation activities at RMA, indications were found that a source of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) had existed on the RMA. As a result, investigations were undertaken to assess the possible nature and extent of any potential sources of PCDDs and PCDFs on the RMA site. In addition, other studies were conducted that examined PCDD/PCDF contamination in the Denver area. The goal of these studies was to examine nature and extent of PCDD/PCDF contamination both on the RMA as well as in the surrounding Denver area. The intent of this study was to characterize sources of dioxins (PCDDs) and dibenzofurans (PCDFs) at low environmental concentrations which might have originated from diffuse sources in the Denver Colorado area and in particular, the Rocky Mountain Arsenal (RMA) using Principal Component Analysis (PCA). Methods Over 200 soil samples were collected from the RMA and the Denver area. From the RMA, soil was collected as part of three studies that included a (1) random site-wide sampling of the RMA, (2) soils from the Western Tier Parcel (WTP), and (3) soils from Historic Use areas. Denver area soil samples were collected from five different land use categories: Residential, Agricultural, Open Space, Commercial, and Industrial. PCA was conducted on concentrations of 17 2,3,7,8-substuituted PCDD and PCDF congeners in 220 soil samples collected from the RMA and the Denver Front Range region. Results and Discussion PCA demonstrated the presence of possible minor sources of dioxins on the RMA. Current remediation efforts on RMA will result in the removal of these sources. Samples from the RMA were identified by the presence of a congener profile containing higher chlorinated PCDFs while the Denver Front Range areas were characterized by the presence of higher chlorinated PCDD congeners. The presence of a PCDF signature for the RMA samples does not necessarily indicate a major source of these contaminants on-site. Indeed, the relatively diffuse nature of the sample clusters would argue strongly against the presence of a single large source. Instead, the predominance of the PCDF congeners probably indicates the mixed industrial activities that took place on and near the site. Conclusion PCA results indicate that PCDD/PCDF profiles in soils collected from the RMA differed from those collected from the outlying Denver areas but that a major source of these contaminants was not present. Rather, the diffuse nature of sample clusters from the PCA indicated that the congener profile of RMA samples was most likely a result of the mixed industrial activities that historically have taken place on and near the site. PCA also indicated that many of the 'open area' (peripheral site-wide) RMA soils samples did not differ from Denver are reference congener profiles. This finding was also true for samples collected from the WTP that were essentially indistinguishable from Off-RMA reference samples. In addition, total TEQ concentrations in soils collected from WTP were similar to those measured in soils collected from the Denver Front Range areas indicating that lack of a major source of PCDD/PCDF within the WTP zones of the RMA. Recommendation and Outlook Analytical as well as statistical results of the soil congener data indicate that the WTP soils are indistinguishable from soils collected from non-industrial areas in the Denver area. This finding would support the recent 'de-listing' of the WTP from the other RMA areas and its' transfer to other authorities in the Denver area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号