首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Relatively "old" (stabilized) landfill leachates are a special category of wastewaters, which are difficult to treat further, mainly due to their bio-refractory organic content (humic substances). In this study, coagulation-flocculation was examined as post-treatment method for the biologically pre-treated stabilized leachates. The purpose was to examine the coagulation performance of alternative coagulant agents, i.e. the composite coagulant polyaluminium silicate chloride. Composite coagulants with different Al to Si molar ratio and different preparation methods were tested. Their efficiency was evaluated by monitoring from turbidity and phosphate content, other parameters strongly correlated with the presence of organic matter, such as UV absorbance at 254nm, COD and colour. The results suggest that the silica-based coagulants exhibit better coagulation performance, than the relevant conventional coagulant (alum) or simple pre-polymerized coagulants (PACl). Polyaluminium silicate chloride has greater tolerance against pH variation than alum or PACl, whereas this novel coagulant works better at pH values between 7 and 9. Coagulation-flocculation has proved to be an efficient post-treatment method for the biologically pre-treated leachates, promoting the removal of the refractory humic substances, while the treatment efficiency of coagulation can be improved by the application of the new coagulant agent.  相似文献   

2.
An integrated technique consisted of ozonation and coagulation/flocculation processes was studied, aiming to provide an efficient method for the treatment of stabilized/biologically pre-treated leachates, in order to reduce the organic pollutants' content to concentration values lower than the corresponding limits, imposed by the legislation. Leachates were collected from a municipal landfill site; samples containing around 1000 mg l(-1) COD and BOD(5)/COD ratio about 0.17 were treated by using two different processes or combinations between them, i.e. ozonation, coagulation-flocculation, ozonation followed by coagulation/flocculation and coagulation/flocculation followed by ozonation. The application of single ozonation resulted to the efficient removal of color and organic loading, due to the respective oxidation, induced by ozonation; however, COD values lower than 200 mg l(-1) could be only achieved after prolonged reaction times and for high ozone production rates. The coagulation of leachate samples was studied by the addition of ferric chloride or poly-aluminum chloride agents at various dosages. Maximum COD removal rates (up to 72%) were achieved by the addition of 7 mM Fe, or of 11 mM Al respectively. However, final COD values higher than 200 mg l(-1) were obtained indicating the requirement of an additional treatment step. Pre-ozonation followed by coagulation/flocculation was not found to be an efficient treatment approach for this aim, but coagulation/flocculation followed by ozonation, was proved to be an efficient process for the reduction of COD to lower than 180 mg l(-1).  相似文献   

3.
滤布滤池强化处理城市二级出水中试研究   总被引:3,自引:1,他引:2  
采用滤布滤池对南方某城市污水处理厂二级出水进行强化处理中试研究,以达到中水回用的目的。实验选用氯化铁(FeCl3)、聚合氯化铝铁(PAFC)和聚合氯化铝(PAC)作为强化滤布滤池除磷效果的混凝剂。当不投加混凝剂时,滤布滤池对TP和COD的平均去除率为28.76%和8%,其中TP的去除效果受进水水质影响较大;当投加氯化铁、聚合氯化铝铁与聚合氯化铝强化滤布滤池时,滤布滤池对TP的平均去除率分别为63.58%、60.13%和66.94%,TP去除效果受进水水质影响较小;对SS的平均去除率分别为70.7%、64.3%和49.1%;对COD平均去除率分别为17.7%、26.3%和27.7%。滤布滤池对TN和NH3-N去除效果不稳定。  相似文献   

4.
电解氧化处理难降解垃圾渗滤液研究   总被引:1,自引:1,他引:0  
采用连续式电解槽对垃圾渗滤液进行电解催化处理,考察极板间距、电流密度、电导率[Cl-]浓度对电解效果的影响.结果表明,当添加的[Cl-]6000 mg/L,在电解60 min时,对初始COD小于3000 mg/L的中等浓度渗滤液有较好的处理效果,COD和NH3-N的去除率分别达88.9%和97.3%,能耗为2.75 kwh/m3.为中试和工业设计应用提供了参考.  相似文献   

5.
The main objective of this study was to investigate the feasibility of coagulation as a post-treatment method of anaerobically treated primary municipal wastewater. Both mesophilic and ambient (20 degrees C) temperature conditions were investigated in a laboratory-scale upflow anaerobic sludge bed (UASB) reactor. In addition, optimization of the coagulant, both in terms of type and dose, was performed. Finally, phosphorus removal by means of aluminum and iron coagulation and phosphorus and ammonia nitrogen removal by means of struvite precipitation were studied. Anaerobic treatment of primary effluent at low hydraulic retention times (less than 15 hours) resulted in mean chemical oxygen demand (COD) removals ranging from 50 to 70%, while, based on the filtered treated effluent, the mean removals increased to 65 to 80%. Alum coagulation of the UASB effluent gave suspended solids removals ranging from approximately 35 to 65%. Turbidity removal reached up to 80%. Remaining COD values after coagulation and settling were below 100 mg/L, while remaining total organic carbon (TOC) levels were below 50 mg/L. Filterable COD levels were generally below 60 mg/L, while filterable TOC levels were below 40 mg/L. All coagulants tested, including prepolymerized aluminum and iron coagulants, demonstrated similar efficiency compared with alum for the removal of suspended solids, COD, and TOC. Regarding struvite precipitation, optimal conditions for phosphorus and nitrogen removal were pH 10 and molar ratio of magnesium: ammonia-nitrogen: phosphate-phosphorus close to the stoichiometric ratio (1:1:1). During struvite precipitation, removal of suspended solids reached 40%, while turbidity removal reached values up to 80%. The removal of COD was approximately 30 to 35%; yet, when removal of organic matter was based on the treated filterable COD, the removal increased to approximately 65%. In addition, nitrogen was removed by approximately 70%, while phosphorus removal ranged between approximately 30 and 45% on the basis of the initial phosphorus concentration. Finally, size fractionation of the organic matter (COD) showed that the various treatment methods were capable of removing different fractions of the organic matter.  相似文献   

6.
用聚硅酸铁铝对垃圾渗沥液进行预处理的研究   总被引:6,自引:0,他引:6  
采用一种新型高效的无机高分子混凝剂——聚硅酸铁铝(PSAF)用于垃圾渗沥液亚滤装置的预处理。结果表明,在PSAF的投加量为150mg/L,pH为5.0和沉降时间为60min的条件下,混凝效果最佳,浊度去除率可达92%左右,色废去除率可达91%左右,CODcr去除率可达70%左右。同时探讨了该混凝剂处理垃圾渗沥液的反应机理。  相似文献   

7.
Physical-chemical methods have been suggested for the treatment of low strength municipal landfill leachates. Therefore, applicability of nanofiltration and air stripping were screened in laboratory-scale for the removal of organic matter, ammonia, and toxicity from low strength leachates (NH4-N 74-220 mg/l, chemical oxygen demand (COD) 190-920 mg O2/l, EC50 = 2-17% for Raphidocelis subcapitata). Ozonation was studied as well, but with the emphasis on enhancing biodegradability of leachates. Nanofiltration (25 degrees C) removed 52-66% of COD and 27-50% of ammonia, the latter indicating that ammonia may in part have been present as ammonium salt complexes. Biological pretreatment enhanced the overall COD removal. Air stripping (24 h at pH 11) resulted in 89% and 64% ammonia removal at 20 and 6 degrees C, respectively, the stripping rate remaining below 10 mg N/l h. COD removals of 4-21% were obtained in stripping. Ozonation (20 degrees C) increased the concentration of rapidly biodegradable COD (RBCOD), but the proportion of RBCOD of total COD was still below 20% indicating poor biological treatability. The effect of the different treatments on leachate toxicity was assessed with the Daphnia acute toxicity test (Daphnia magna) and algal growth inhibition test (Raphidcocelis subcapitata). None of the methods was effective in toxicity removal. By way of comparison, treatment in a full-scale biological plant decreased leachate toxicity to half of the initial value. Although leachate toxicity significantly correlated with COD and ammonia in untreated and treated leachate, in some stripping and ozonation experiments toxicity was increased in spite of COD and ammonia removals.  相似文献   

8.
用聚二甲基二烯丙基氯化铵(PDM)、聚合氯化铝(PAC)按照质量比1%制备了复配混凝剂,研究了其理化特性及原水污染物去除效果。利用Al-Ferron逐时络合比色法研究了复配混凝剂的铝(Ⅲ)形态分布,结果表明,Ala、Alb和Alc分别占12.62%、16.02%和71.36%。复配混凝剂Zeta电位平均值为41.6 mV。红外吸收光谱分析表明复配混凝剂的羟基缔合程度比PAC要高。扫描电镜结果表明,固体复配混凝剂表面较为粗糙、结构疏松。相同投加量时,复配混凝剂对江河水、水库水的浊度、CODMn、UV254的去除效率均优于PAC。实验利用针杆藻人工模拟高藻原水,当投加PDM:PAC质量比10%的复配混凝剂10 mg/L时,复配混凝剂对藻类的去除率为80.5%。  相似文献   

9.
生活垃圾焚烧发电厂渗滤液蒸发浓缩处理   总被引:1,自引:0,他引:1  
垃圾焚烧厂渗滤液因水质复杂,NH3-N、COD和电解质含量高等特点,成为一种难处理有机废水。采用负压蒸发浓缩法对渗滤液及电絮凝预处理渗滤液的处理进行了对比研究,并考查了浓缩比、pH等因素的影响。研究结果表明,电絮凝预处理不能改变渗滤液中COD、NH3-N的蒸发去除规律,即蒸发处理过程中,蒸发冷凝液中COD在蒸发前期和后期含量较高,蒸发中期较低;而NH3-N含量在蒸发处理前期较高,中后期含量较低。pH对蒸发处理影响较大,在酸性pH下COD去除率较低,但NH3-N去除率较高,可达95%以上,而在中碱性pH下,COD去除率增高,NH3-N去除率降低。渗滤液及电絮凝预处理渗滤液的一次蒸发冷凝液,经过二次蒸发处理后,冷凝液中COD和NH3-N含量均能达到一级排放标准,即分别低于100 mg/L和15 mg/L。  相似文献   

10.
多核复合聚铝絮凝剂对水体残留铝的影响   总被引:2,自引:2,他引:0  
采用分别添加金属离子Fe~(3+)和Zn~(2+)的方法制备多核复合型絮凝剂聚合氯化铝铁(PAFC)和聚合氯化铝锌(PAZC),并与市售聚合氯化铝(PAC)比较处理高岭土模拟水样后出水残留铝浓度,得出复合絮凝剂具有更低的出水余铝量及更宽的pH适用范围以及更低的投加量。达到85%COD去除率,PAZC、PAFC和PAC用量分别为5、10和20 mg/L;处理后出水残余铝量分别为0.04、0.09和0.14 mg/L;处理成本分别为0.020、0.028和0.048元/t。  相似文献   

11.
Evaluation of modified clay coagulant for sewage treatment   总被引:1,自引:0,他引:1  
Jiang JQ  Zeng Z  Pearce P 《Chemosphere》2004,56(2):181-185
The use of modified clays as coagulants for sewage treatment was investigated in this study. The raw clays were montmorillonites K10 and KSF, and were modified by polymeric Al or Fe and/or Al/Fe mixing polymeric species. The comparative performance of modified clays and aluminium sulphate and ferric sulphate were evaluated in terms of the removal of turbidity, suspended solids, UV(254)-abs, colour, and total and soluble CODs. The results demonstrated that after being modified with mixing polymeric Al/Fe species, two montmorillonite clays possess greater properties to remove the particles (as suspended solids) and organic pollutants (as COD and UV(254)-abs) from the sewage and to enhance the particle settling rate significantly.  相似文献   

12.
The purpose of the study was the experimental evaluation of ultrafiltration as a potential innovative technology for the removal of organic matter of around 15,000 mg chemical oxygen demand (COD) per liter in the polymer industry wastewater. Particle size distribution (PSD) analysis served as the major experimental instrument along with conventional chemical settling. Biodegradation characteristics of the remaining COD after ultrafiltration were determined by model interpretation of the corresponding oxygen uptake rate (OUR) profile. The study first involved a detailed characterization of the polymer wastewater including PSD analysis of the COD content. Chemical treatability was investigated using lime alone and with ferric chloride as coagulants followed with a PSD assessment of the chemically settled effluent. Modeling of the OUR profile generated by the ultrafiltration effluent defined related biodegradation kinetics and provided information on the overall COD removal potential. PSD analysis indicated that more than 70 % of the total COD accumulated in the 220- to 450-nm size range. It indicated that ultrafiltration was potentially capable of removing more than 90 % of the COD with an effluent lower than 1,500 mg COD/L. Chemical settling with 750 mg/L of FeCl3 dosing at a pH of 7.0 provided a similar performance. The ultrafiltration effluent included mainly hydrolysable COD and proved to be biodegradable, with the process kinetics compatible with domestic sewage. PSD evaluation proved to be a valuable scientific instrument for underlining the merit of ultrafiltration as the appropriate innovative technology for polymer wastewater, removing the major portion of the COD in a way that is suitable for recovery and reuse and producing a totally biodegradable effluent.  相似文献   

13.
A new inorganic-organic hybrid material zirconium-glycine complex (ZGC) was firstly used as a coagulant in a coagulation process to treat Pearl River raw water. Its coagulation performance was compared with commonly used aluminum (Al) coagulants such as aluminum sulfate (Al2(SO4)3) and polyaluminum chloride (PAC), in terms of water quality parameters and floc properties. ZGC coagulation achieved higher removal of turbidity (93.8 %) than other traditional coagulants. Charge neutralization was proven to act as a dominant mechanism during ZGC coagulation. The aggregated flocs with ZGC showed the fastest growth rate and good recovery ability compared with the other coagulants and achieved the largest floc size within 5 min. The ZGC coagulant can decrease the hydraulic retention time and increase removal efficiency.  相似文献   

14.
Treatment of refectory oily wastewater by electro-coagulation process   总被引:7,自引:0,他引:7  
Xu X  Zhu X 《Chemosphere》2004,56(10):889-894
Electro-coagulation was used to treat refectory wastewater with high oil and grease contents. Different operational conditions were examined, including pH, current density, reaction time, conductivity, electrode distance and inlet concentration. The optimum current density was 10-14 A m(-2) within 30 min depending on the wastewater properties tested. Conductivity had little effect on the treatment efficiency. Although the addition of extra salts (e.g., sodium chloride) to the wastewater did not help increase the pollutant removal efficiency, it could save the power consumption significantly. The COD(Cr) and oil removal efficiency descended with increasing electrode distance. The optimal electrode distance was determined to be 10 mm for this equipment in consideration of the treatment cost and efficiency together. The pH effect on the performance of the electro-coagulation process was not very significant in the range of 3-10. The removal efficiency of oil and COD(Cr) under normal condition exceeded 95% and 75%, respectively.  相似文献   

15.
不同形态铁盐的除磷效果   总被引:2,自引:2,他引:0  
研究不同铁盐存在形态的铁盐类混凝剂,即三氯化铁(离子态铁)、聚合氯化铁(聚合态铁)和氢氧化铁(凝胶态铁),在混凝除磷性能方面的差异。以城市污水厂的二级出水为实验水样,进行混凝除磷性能研究。结果表明,二级出水总磷为1.74 mg/L,离子态铁投加量为40 mg/L时,对总磷的去除率为90%,混凝处理后上清液总磷可达《城镇污水处理厂污染物排放标准》(GB18918-2002)中的一级A标准,聚合态铁对总磷的去除率为62%,凝胶态氢氧化铁的总磷去除率为59%,混凝处理后上清液总磷均不能满足GB18918-2002中的一级A标准。离子态氯化铁对污水厂二级出水的除磷效果优于聚合态,即铁离子的聚合形态会影响其除磷效果。  相似文献   

16.
Photochemically-assisted electrochemical degradation of landfill leachate   总被引:5,自引:0,他引:5  
In this work, the treatment of landfill leachates by a photoelectrochemical procedure is reported. When applied to untreated leachates the photochemical system was significantly hindered on account of the characteristic dark coloration of the samples. At this condition the degradation process was essentially electrochemical permitting typical color and COD removal of about 50% and 20%, respectively. When a previous chemical precipitation process was applied aiming the elimination of colored species (mainly humic substances) the decolorization and COD removal was extended to 90% and 60%, respectively. Considering the extremely complex character of the leachates and its usual resistance to conventional degradation processes the result reported here attest the high potentiality of photoelectrochemical processes to remediation of recalcitrant residues.  相似文献   

17.
采用混凝剂对皮革废水进行混凝处理。对3种无机混凝剂和一种有机混凝剂进行了筛选,研究了pH值和投药量对废水中SS、COD、铬和色度等污染物去除效果的影响。结果表明,当pH值在酸性和中性时,效果不明显;当pH值为碱性时,效果显著。硫酸亚铁、硫酸亚铁+PAM和聚合氯化铝(PAC)+PAM 3种混凝剂组合具有良好的混凝效果,在合适的pH值和投药量下,SS和COD的去除率分别达到80%和30%以上,铬和色度的去除率分别达到95%和50%以上。且硫酸亚铁混凝效果好,成本低,适合小型皮革企业需求。  相似文献   

18.
针对某钼矿选矿厂浮选废水,以PAC、PFS和FeCl3为凝聚剂,以APAM-A和APAM-N为絮凝剂,以H2SO4和NaOH为pH调整剂,研究了不同混凝剂、不同pH值和不同水力条件下废水处理后的浊度和COD.实验结果表明,在最佳水力条件下,原水pH不调整,以APAM-A为絮凝剂,以PAC为凝聚剂,其用量分别为15 g/t,750g/t时,处理后上清液浊度为25 NTU,COD小于30 mg/L.浮选废水经处理后回用于选矿浮选流程,大大改善了选矿指标.  相似文献   

19.
制浆造纸废水生化出水的混凝处理研究   总被引:1,自引:0,他引:1  
研究了硫酸铝和三氯化铁对制浆造纸废水生化出水的处理效果.研究发现,不调节原水pH值,硫酸铝投加量为600 mg/L或三氯化铁投加量为300mg/L时,混凝后废水的COD<150 mg/L,色度<50倍,出水均符合现阶段排放标准.混凝剂比较发现,在最佳反应条件下,2种混凝剂的处理效果相当,但硫酸铝混凝的成本低于三氯化铁....  相似文献   

20.
在研究氢氧化镁混凝特性的基础上,复配氯化镁和硫酸铝作为混凝剂,以高岭土配水水样为研究对象,运用iPDA在线监测技术对混凝过程絮体形成进行监测,探讨了单独使用氯化镁和硫酸铝以及二者复配使用的混凝效果和絮体特性,确定复配使用的各种条件。结果表明,对于浊度20 NTU,pH 11.5的高岭土配水水样,氯化镁、硫酸铝最佳投加量分别为7.2 mg/L(Mg2+计)和3 mg/L(Al3+计);硫酸铝跟氯化镁复配使用时,先投加硫酸铝,间隔30 s后投加氯化镁,混凝效果较好;在镁离子最佳投加量7.2 mg/L时,铝和镁最佳质量比在1∶3~1∶2之间;镁铝复配时其FI值明显大于单独作用时,即絮体尺寸大小:二者复配硫酸铝氯化镁,而且复配条件下Zeta电位值在零电势左右浮动,浮动范围小,更利于聚集沉淀;镁铝复配时发生了协同效应,弥补了单独使用氯化镁混凝过程的不足。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号