首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The nitrogen-removal performances of three full-scale piggery wastewater treatment plants, with different organic and nitrogen loads, at the capacity ranges of 95 to 130 m3/d, were compared in this study. Plants 1 and 2 can be characterized as the modification of anoxic-aerobic operating systems, while an anaerobic and anoxic-aerobic system was used in plant 3. The influent piggery wastewater concentration for plant 1 was relatively lower, but with higher organic and nitrogen loads, resulting in higher chemical oxygen demand (COD) and ammonium-nitrogen in effluent. Plant 2 was operated with strong piggery wastewater, resulting in a higher operating temperature. The high temperature could inhibit the nitrifying activity in plant 2. Although plant 3 was operated with a higher influent total COD-to-total Kjeldahl nitrogen ratio (TCOD:TKN), an additional external carbon source was required to polish the final effluent to remove nitrogen. Influent COD in plant 3 was used in the anaerobic-anoxic reactor for both methane (CH4) production and denitrification. Based on various mass balances, including caloric, COD, and alkalinity, the key elements for the successful nitrogen removal from the piggery waste were reactor temperature (less than 35degrees C), influent TCOD:TKN (greater than 6), and alkalinity-to-TKN ratio (greater than 3).  相似文献   

2.
In the present study, feasibility of recovering the coagulant from water treatment plant sludge with sulphuric acid and reusing it in post-treatment of upflow anaerobic sludge blanket (UASB) reactor effluent treating municipal wastewater were studied. The optimum conditions for coagulant recovery from water treatment plant sludge were investigated using response surface methodology (RSM). Sludge obtained from plants that use polyaluminium chloride (PACl) and alum coagulant was utilised for the study. Effect of three variables, pH, solid content and mixing time was studied using a Box–Behnken statistical experimental design. RSM model was developed based on the experimental aluminium recovery, and the response plots were developed. Results of the study showed significant effects of all the three variables and their interactions in the recovery process. The optimum aluminium recovery of 73.26 and 62.73 % from PACl sludge and alum sludge, respectively, was obtained at pH of 2.0, solid content of 0.5 % and mixing time of 30 min. The recovered coagulant solution had elevated concentrations of certain metals and chemical oxygen demand (COD) which raised concern about its reuse potential in water treatment. Hence, the coagulant recovered from PACl sludge was reused as coagulant for post-treatment of UASB reactor effluent treating municipal wastewater. The recovered coagulant gave 71 % COD, 80 % turbidity, 89 % phosphate, 77 % suspended solids and 99.5 % total coliform removal at 25 mg Al/L. Fresh PACl also gave similar performance but at higher dose of 40 mg Al/L. The results suggest that coagulant can be recovered from water treatment plant sludge and can be used to treat UASB reactor effluent treating municipal wastewater which can reduce the consumption of fresh coagulant in wastewater treatment.  相似文献   

3.
Microbial kinetic analysis of three different types of EBNR process   总被引:3,自引:0,他引:3  
Pai TY  Tsai YP  Chou YJ  Chang HY  Leu HG  Ouyang CF 《Chemosphere》2004,55(1):109-118
The disadvantages of developed biological nutrient removal (BNR) processes (additional energy for liquid circulation and addition of external carbon substrate for denitrification in anoxic zones) were improved by reconfiguring the process into (1) an anaerobic zone followed by multiple stages of aerobic-anoxic zones (TNCU3 process) or (2) anaerobic, oxic, anoxic, oxic zones in sequence (TNCU2 process). These two pilot plants were operated at a recycling sludge ratio of 0.5 without internal recycle of nitrified supernatant. The sludge retention time was maintained at 10 d. The main objective of this study is to analyze the kinetics of different microorganisms in these two processes and A2O process by using the Activated Sludge Model No. 2d. The effective removal efficiency of carbon, total phosphorus and total nitrogen at 87-98%, 92-100% and 63-80%, respectively, were achieved in the testing runs. According to model simulations, the microbial kinetics in the TNCU3 and TNCU2 processes would be affected by different operations. When the step feeding strategy was adopted, the HRT was longer due to the less influent flowrate in the front stages and the microbes would grow in quantities by about 6% in the aerobic reactors. In the followed anoxic reactors, the microbes would decrease in quantities by about 12% due to the dilution effect. The dilution effects in TNCU3 and TNCU2 processes did not take place in A2O process because the recycling mixed liquid from the aerobic reactor to the anoxic reactor still contained particulate components. The XH, XPAO, and XAUT concentrations in the effluent of the last tank were lower when the step-feeding mode was adopted. The TNCU3 and TNCU2 processes could be operated efficiently without nitrified liquid circulation and addition of external carbon substrate for denitrification.  相似文献   

4.

Wastewater treatment plants (WWTP) are highly non-linear operations concerned with huge disturbances in flow rate and concentration of pollutants with uncertainties in the composition of influent wastewater. In this work, the activated sludge process model with seven reactor configuration in the ASM3bioP framework is used to achieve simultaneous removal of nitrogen and phosphorus. A total of 8 control approaches are designed and implemented in the advanced simulation framework for assessment of the performance. The performance of the WWTP (effluent quality index and global plant performance) and the operational costs are also evaluated to compare the control approaches. Additionally, this paper reports a comparison among proportional integral (PI) control, fuzzy logic control, and model-based predictive control (MPC) configurations framework. The simulation outcomes indicated that all three control approaches were able to enhance the performance of WWTP when compared with open loop operation.

  相似文献   

5.
Subsurface drip irrigation systems apply effluent from onsite wastewater systems in a more uniform manner at a lower rate than has been possible with other effluent dispersal methods. The effluent is dispersed in a biologically active part of the soil profile for optimal treatment and where the water and nutrients can be utilized by landscape plants. Container tests were performed to determine the fate of water and nitrogen compounds applied to packed loamy sand, sandy loam, and silt loam soils. Nitrogen removal rates measured in the container tests ranged from 63 to 95% despite relatively low levels of available carbon. A Hydrus 2D vadose zone model with nitrification and denitrification rate coefficients calculated as a function of soil moisture content fit the container test results reasonably well. Model results were sensitive to the denitrification rate moisture content function. Two-phase transport parameters were needed to model the preferential flow conditions in the finer soils. Applying the model to generic soil types, the greatest nitrogen losses (30 to 70%) were predicted for medium to fine texture soils and soils with restrictive layers or capillary breaks. The slow transport with subsurface drip irrigation enhanced total nitrogen losses and plant nitrogen uptake opportunity.  相似文献   

6.
采用A/O-CSTR工艺处理高氨氮污泥脱水液。进水氨氮浓度浓度约为375 mg/L,C/N比小于1.0,反硝化碳源明显不足。A/O反应器完成短程硝化反应,CSTR定期投加初沉污泥作为碳源进行反硝化。两者联合达到总氮去除的目的。实验研究短程硝化反应的启动过程,以及CSTR出水回流对短程硝化和系统脱氮效果的影响。实验结果表明系统具有良好的硝化反硝化效果。A/O反应器亚硝酸盐积累率迅速提高并稳定在90%以上。CSTR有效利用初沉污泥实现了稳定的反硝化。出水回流有利于提高总氮去除率,在回流比为200%时,系统平均总氮去除率达到85%以上。  相似文献   

7.
Chemical and microbiological aspects were investigated with regard to biological denitrification of drinking water using the seaweed Gracilaria verrucosa as the carbon and energy substrate and as physical support for the microbial flora in semibatch, fixed-bed reactors. Complete removal of nitrate (100 mg/L) was readily achieved without accumulation of nitrite. Microbiological analysis indicated that the effluent of the reactor contained high numbers of bacteria (>10(6)/mL total count). Among the 44 bacterial strains isolated directly from the samples or isolated after enrichment at 37 degrees C, 25 different fatty acid profiles were found, indicating a complex microflora, including potential pathogens.  相似文献   

8.
With the concerns of ecological and circular economy along with sustainable development, reverse logistics has attracted the attention of enterprise. How to achieve sustainable development of reverse logistics has important practical significance of enhancing low carbon competitiveness. In this paper, the system boundary of reverse logistics carbon footprint is presented. Following the measurement of reverse logistics carbon footprint and reverse logistics carbon capacity is provided. The influencing factors of reverse logistics carbon footprint are classified into five parts such as intensity of reverse logistics, energy structure, energy efficiency, reverse logistics output, and product remanufacturing rate. The quantitative research methodology using ADF test, Johansen co-integration test, and impulse response is utilized to interpret the relationship between reverse logistics carbon footprint and the influencing factors more accurately. This research finds that energy efficiency, energy structure, and product remanufacturing rate are more capable of inhibiting reverse logistics carbon footprint. The statistical approaches will help practitioners in this field to structure their reverse logistics activities and also help academics in developing better decision models to reduce reverse logistics carbon footprint.  相似文献   

9.
Model continuous activated sludge (CAS) plants (Husmann units) were used to study the fate of two commercial, alcohol ethoxylate (AE) surfactants during aerobic sewage treatment. The surfactants were produced by the ethoxylation of an essentially linear C(12-15) alcohol (NEODOL 25) with an average of 7 (C(12-15)EO7) or 3 (C(12-15)EO3) moles of ethylene oxide (EO). Recent analytical developments made it possible to measure levels of AE that included the free alcohol and EO1 oligomers across the CAS system, from the influent feed, on the activated sludge, through to the effluent. Measured concentrations of AE (as C(12-15)EO(0-20)) in the synthetic sewage feeds to the test CAS plants lay in the range 11-13 mg/l. During stable operation at 20 degrees C, an average of 5 microg/l AE were present in the C(12-15)EO7 CAS plant effluent, giving a removal (bioelimination) of >99.9%. When levels of AE on the sludge, and polyethylene glycols (PEGs--an expected biodegradation intermediate) in the effluent and on the sludge were also taken into account, biodegradation was considered to be responsible for >98.7% of the observed removal. During operation at a winter temperature (10 degrees C), an average of 26 microg/l AE were present in the C(12-15)EO7 CAS plant effluent, giving a removal of 99.8%. Biodegradation was estimated to be responsible for >97.2% of the observed removal. During operation at 20 degrees C, an average of 7 microg/l AE were present in the C(12-15)EO3 CAS plant effluent, giving a removal of >99.9%. No analysis for PEG was performed in this case but the low level of AE on the sludge (0.2 mg/g dry solids) suggested that biodegradation was responsible for most of the observed removal. Neither surfactant had any adverse effect on the sewage treatment efficiencies of the CAS plants in terms of dissolved organic carbon (DOC) removal, nitrification or biomass levels.  相似文献   

10.
This work examines the performance of a hydrous ferric oxide (HFO) reactive filtration (RF) process with coupled chemically enhanced secondary treatment (RECYCLE) for phosphorus removal from municipal wastewater (HFO-RF-RECYCLE). A 3-month, 0.95-ML/d (0.25-mgd) demonstration of HFO-RF-RECYCLE was performed at a municipal wastewater treatment plant equipped with oxidation ditches and secondary clarifiers. Influent to the plant averaged 6.0 mg/L phosphorus, with a tertiary effluent average of 0.011 mg/L phosphorus. Iron doses to the plant were low, at 5 mg/L. Inline recycling of HFO solution rejects to the plant influent resulted in a maximum 90.3%, dose-dependent reduction of phosphorus in the secondary effluent at 4.5 ML/d (1.2 mgd). Other results included reduction of total suspended solids and turbidity. A mass balance analysis was performed. We conclude that HFO-RF-RECYCLE may allow very low levels of phosphorus discharge from municipal wastewater treatment plants with a ferric-iron-based tertiary filtration process and residual recycling.  相似文献   

11.
固定化菌藻系统对污水处理厂出水的深度处理   总被引:4,自引:1,他引:3  
严清  高旭  彭绪亚 《环境工程学报》2012,6(10):3629-3634
将海藻酸钠固定化活性污泥和小球藻制成颗粒小球,以自制的流化床反应器对重庆市某污水处理厂出水进行深度处理,探讨了系统对氨氮、TP、COD的去除效果,实验结果表明:在HRT=12 h,溶解氧浓度为3.0 mg/L左右,pH值为6.2至8.0之间,环境室温条件下,系统对氨氮、TP、COD均有较好的去除效果,系统稳定运行后对氨氮、TP、COD去除率基本维持在60%、60%和30%以上,出水氨氮、TP、COD浓度基本维持在8、0.5和40 mg/L以下,出水浓度达到了《城镇污水处理厂污染物排放标准》(GB 18918-2002)的一级A标准。这项研究显示固定化菌藻胶球系统在污水处理厂出水的深度处理中具有潜在的应用前景。  相似文献   

12.
Two biological nutrient removal modes, consisting of anaerobic, anoxic, and oxic sequences, were tested in a full-scale sequencing batch reactor. The modes, identified as BNR-S1 and BNR-S2, had average total nitrogen removals of 84 and 89%, respectively, for the months of August to October. Over the same period, total phosphorus removals for BNR-S1 and BNR-S2 were 88 and 87%, respectively. In contrast, total nitrogen and total phosphorus removals for the regular aerobic mode were 54.7 and 44.7%, respectively. When the wastewater temperature changed from approximately 20 to 15 degrees C in the winter months, total nitrogen and total phosphorus removals for BNR-S2 were reduced to 81 and 70%, respectively. Total nitrogen effluent concentrations were between 2.5 and 4 mg-N/L (at approximately 20 degrees C), while the effluent total phosphorus concentrations were between 1 and 2 mg/L. The BNR-S2 mode was found to require less energy per kilogram of soluble chemical oxygen demand removed than the regular and BNR-S1 modes.  相似文献   

13.
Wang J  Long MC  Zhang ZJ  Chi LN  Qiao XL  Zhu HX  Zhang ZF 《Chemosphere》2008,71(1):195-202
Wastewater in Shaoxing wastewater treatment plant (SWWTP) is composed of more than 90% dyeing and printing wastewater with high pH and sulfate. Through a combination process of anaerobic acidogenic [hydraulic retention time (HRT) of 15h], aerobic (HRT of 20h) and flocculation-precipitation, the total COD removal efficiency was up to 91%. But COD removal efficiency in anaerobic acidogenic unit was only 4%. As a comparison, the COD removal efficiency was up to 35% in the pilot-scale upflow anaerobic sludge bed (UASB) reactor (HRT of 15h). GC-MS analysis showed that the response abundance of these wastewater samples decreased with their removal of COD. A main component of the raw influent was long-chain n-alkanes. The final effluent of SWWTP had only four types of alkanes. After anaerobic unit at SWWTP, the mass percentage of total alkanes to total organic compounds was slightly decreased while its categories increased. But in the UASB, alkanes categories could be removed by 75%. Caffeine as a chemical marker could be detected only in the effluent of the aerobic process. Quantitative analysis was given. These results demonstrated that GC-MS analysis could provide an insight to the measurement of organic compounds removal.  相似文献   

14.
依据好氧硝化和缺氧反硝化生物脱氮除碳工艺原理,设计了一体化生物膜法A/O反应器,并将其应用于生活污水处理,取得了理想的处理效果。实验结果表明,水力停留时间HRT=12 h,COD进水浓度处于150~500 mg/L范围内,COD的去除率均在90%以上,且出水均在40 mg/L以下;当C/N比为8.5以下时,NH3-N去除率高于90%,其出水浓度小于5 mg/L;当C/N比为7.5左右时,具有较高的总氮脱除效果,TN去除率可达到70%。  相似文献   

15.
Bioavailability of dissolved organic nitrogen in treated effluents.   总被引:2,自引:0,他引:2  
The research objective was to assess dissolved organic nitrogen (DON) bioavailability in wastewater effluents from a pilot-scale nitrification plant and a laboratory-scale total nitrogen (TN) removal plant. The DON bioavailability was assessed using a 14-day bioassay protocol containing bacterial and algal inocula. Nitrogen species, dissolved organic carbon, chlorophyll a, and biomass (as total suspended solids and culturable cell counts) concentrations were measured to assess DON bioavailability. The results showed an increase in algal chlorophyll a concentration, with a concurrent increase in algal biomass over time; increased bacterial counts and a decrease in DON concentration over time; and increased carbon-to-nitrogen ratio at the end of the 14-day bioassay, indicating effluent DON bioavailability to algae and bacteria. Approximately 18 to 61% of the initial DON in low-total-nitrogen wastewater effluent (TN = 4 to 5 mg/L) sample was bioavailable. The results show that bacteria and algae uptake and release DON during their growth.  相似文献   

16.
Residual chlorine loss due to UV sunlight in the chlorine disinfection contact basins (DCBs) was investigated at two full-scale wastewater treatment plants (WWTPs). Chlorine decay due to solar UV-induced photochemical reaction was found to be significant and had diurnal and seasonal variations. The total chlorine loss due to sunlight ranged from 19 to 26% of the total chlorine chemical use at the two plants studied. Covering chlorine contact basins led to more stable chlorine demand regardless of the diurnal and seasonal sunlight intensity. Therefore, covering chlorine contact basins offers more stable, or accurate, chlorine dosage and effluent residual control and requires less effort by plant operators. A mathematical model was developed to calculate the amount of UV-induced chlorine decay. The model developed can be used to estimate the UV-induced chlorine decay rate and total chlorine loss due to sunlight at WWTPs with various basin configurations, flowrates, chlorine dosages, and geographical locations. The model results allow the capital cost of covering needs to be assessed against the chlorine chemical cost savings.  相似文献   

17.
The objectives of this study were to examine the application of the divalent cation bridging theory (DCBT) to improve settling, dewatering, and effluent quality in pilot-scale reactors and a full-scale system treating an industrial wastewater. This was accomplished by lowering the monovalent-to-divalent (M/D) cation ratio by direct divalent cation addition. Research has shown that the M/D ratio is a potential indicator for settling and dewatering problems at wastewater treatment plants, and M/D ratios above 2 have been associated with poor settling, dewatering, and effluent quality. The M/D ratio of the wastewater in this study ranged from 6 to 20. The cations studied were calcium and magnesium. Results showed that the addition of calcium improved floc properties compared to control reactors with no calcium addition. The reductions in sludge volume index, effluent chemical oxygen demand (COD), and effluent total suspended solids (TSS) were approximately 35, 34, and 55%, respectively, when the M/D ratio was decreased to approximately 2:1. In addition, the cake solids from a belt filter press simulator increased by 72% and the optimum polymer dose required for conditioning was reduced by 70% in the reactor fed the highest calcium concentration when compared to control reactors with no calcium addition. The addition of calcium also decreased the negative effect of high filamentous organism numbers. In general, the addition of magnesium (Mg2+) had similar effects on effluent quality and dewatering properties, although some differences were measured. A full-scale test using calcium addition was performed. Measurements of effluent quality and floc properties were performed before, during, and after the calcium (Ca2+) addition period. The average M/D ratio during these periods was 6.2, 4.6, and 14.0, respectively. The addition of Ca2+ decreased the effluent five-day biochemical oxygen demand, effluent TSS, and effluent COD. The increased Ca2+ concentration also improved dewatering measured by a decrease in specific resistance to filtration and capillary suction time. Overall, the addition of divalent cations to the pilot- and full-scale activated sludge systems improved floc properties and the data fit well with the DCBT.  相似文献   

18.
Three municipal wastewater treatment plants (WWTPs) in southeastern Pennsylvania were sampled to determine the presence and concentrations of 12 natural and synthetic estrogen hormones in the wastewater influent and effluent. The target estrogens were 17alpha-estradiol, estrone, estriol, equilin, 17alpha-dihydroequilin, 17beta-estradiol, 17alpha-ethinyl estradiol, gestodene, norgestrel, levonorgestrel, medrogestone, and trimegestone. One WWTP uses a biofilm reactor (packed-bed trickling filter),and the other two use suspended-growth media (continuously stirred activated sludge reactor and sequential batch reactor). Estrone was detected in all the three plants; estriol and estradiol were detected at two WWTPs; and 17 alpha-dihydroequilin and 17 alpha-ethinyl estradiol were detected at one WWTP. The concentration of estrogens in the influent and effluent of the three treatment plants ranged from 1.2 to 259 ng/L and 0.5 to 49 ng/L, respectively. The percentage removal of estrogens from the aqueous phase ranged from 41 to 99%, except in the case of 17alpha-dihydroequilin; the removal of 17alpha-dihydroequilin was negligible. The suspended-growth media systems showed higher removal efficiencies for estrogens than the biofilm system. The analytical method uses a Varian C-18 solid-phase extraction (Varian Inc., Palo Alto, California), followed by a derivatization with bis(trimethylsilyl)trifluoroacetamide. The detection limits for the estrogen compounds ranged from 0.1 to 10 ng/L using a sample size of 1 L. The method recoveries ranged from 71 to 120%, and the relative standard deviation ranged from 6 to 14% for all the hormones.  相似文献   

19.
IC厌氧反应器处理有机废水启动实验研究   总被引:1,自引:0,他引:1  
设计了一套IC反应器装置,接种啤酒厂生产废水消化污泥,采用人工配水对其进行启动运行,考察了IC反应器的启动运行状况、效果及影响因素,并在反应器运行结束后观察了污泥状态的变化.结果表明,容积负荷提高至4.7 kg/(m3·d),出水COD浓度稳定在250 mg/L左右,去除率维持在85%以上,反应器内出现污泥分层现象,颗...  相似文献   

20.
Energy consumption requirements for air pollution control equipment were studied for varying removal efficiency levels at the Tyler Pipe Industries iron foundry in Tyler, Texas, based on plant fuel consumption data, and on field test measurements of cupola carbon monoxide and particulate control equipment. Natural gas consumption for CO removal increased from 0 in 1970 to 25.4% of the plant total in 1976. Operating costs to achieve 85% CO control increased from 0 in 1970 to $1.61/ton metal in 1976. Increasing cupola incinerator temperature from 800° to 1600° F increased CO removal efficiency from 60 to 97%, but also increased natural gas consumption by 150%. Electricity consumption requirements for 95% to 97% particulate control at the foundry increased from 0.1 % of plant total in 1970 to 18.7% in 1976. Electricity consumption for particulate controls increased plant operating costs from 0.004 in 1970 to 1.693 $/ton metal in 1976 as horsepower increased from 20 to 6,272. Cost-benefit methodology is needed to evaluate trade-offs between air pollution control, energy consumption requirements and operating costs of proposed regulations. Total air pollution control system must be considered in enforcing regulations instead of the source to be controlled alone for overall impacts. Need exists for process modifications to enhance energy recovery and development of energy-effective air pollution control equipment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号