首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

2.
The construction in Constantí (Catalonia, Spain) of a new hazardous waste incinerator (HWI), which is the first one in Spain, finished in 1999. In order to determine the temporal variation (1996–1998) in the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in the vicinity of the new HWI, 40 soil and 40 herbage samples were collected (1998) at the same sampling points in which samples had been taken two years before (1996). Each sample was analyzed for PCDDs and PCDFs by high resolution gas chromatography/high resolution mass spectrometry. In the 1996 survey, PCDD/F concentrations in soils ranged from 0.13 to 24.20 ng I-TEQ/kg (d.m.), with median and mean values of 0.67 and 1.68 ng I-TEQ/kg (d.m.), respectively. In the present study, PCDD/F concentrations ranged from 0.12 to 17.20 ng I-TEQ/kg (d.m.), with a median value of 0.75 ng I-TEQ/kg (d.m.) and a mean value of 1.59 ng I-TEQ/kg (d.m.). In turn, in the present study PCDD/F concentrations in vegetation ranged from 0.14 to 2.01 ng I-TEQ/kg (d.m.) (median and mean values: 0.23 and 0.31 ng I-TEQ/kg, respectively), while in the 1996 survey PCDD/F concentrations ranged from 0.24 to 1.22 ng I-TEQ/kg (d.m.) (median and mean values: 0.53 and 0.61 ng I-TEQ/kg, respectively). According to the present (1998) and the previous (1996) levels of PCDD/Fs found in soils and vegetation, the area under potential influence of the new facility shows a rather low contamination by these compounds. The current results should be useful to establish the environmental impact of the HWI.  相似文献   

3.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

4.
Municipal solid waste incinerators (MSWIs) have long been the major contributors of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to ambient air in Taiwan. After stringent MSWI emission standards were introduced in 2001, the long-term continuous monitoring of flue gas and ambient air quality became necessary to ensure the effectiveness of the related control strategies. Three MSWIs and the surrounding ambient air were investigated in the current study for PCDD/F characteristics during 2006 to 2011. The average concentrations in the flue gas ranged from 0.008?~?0.0488 ng I-TEQ/Nm3, which is much less than the emission standard in Taiwan (0.1 ng I-TEQ/Nm3) (I-TEQ is the abbreviation of International Toxic Equivalent). This led to extremely low levels in the ambient air, 0.0255 pg I-TEQ/Nm3, much less than the levels seen in most urban areas around the world. Additionally, the results obtained using the Industrial Source Complex Short-Term Dispersion Model (ISCST3) indicate that the PCDD/F contributions from the three MSWIs to the ambient air were only in the range from 0.164?~?0.723 %. Principal component analysis (PCA) showed that the PCDD/Fs in the air samples had very similar characteristics to those from mobile sources. The results thus show that stringent regulations have been an effective control strategy, especially for urban areas, such as Taipei City.  相似文献   

5.
Levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in both air and soil samples were measured at three different sites in Italy, in proximity to three municipal solid waste incinerators (MSWIs) to determine baseline contamination and the contributory role of incinerator emissions. At the first site, located in an agricultural, cattle-breeding, typically flattish area of the Po Valley, the dioxin concentrations had already been measured before the start-up of the new MSWI. These dioxin concentrations were then again measured after two years of continual operation of the incinerator. Despite the presence of the plant, the PCDD/Fs concentrations appear not to have been affected and were found to be in a range of 22-125 fg I-TEQ m(-3) in the air samples and 0.7-1.5 pg I-TEQ g(-1) in the soil samples. The second site is located in an industrial district of the Veneto Region, in the surroundings of an old MSWI that is not equipped with Best Available Technology (BAT) dioxin removal system. The PCDD/Fs concentrations in the air samples were between 144 and 337 fg I-TEQ m(-3). This is a typical range of values for industrial areas, while the soil samples showed contamination levels between 1.1 and 1.4 pg I-TEQ g(-1). The third site lies in the Adige Valley, near a MSWI that has been equipped with BAT for flue gas cleaning. The observed values ranged from 10 to 67 fg I-TEQ m(-3) for the air samples and 0.08-1.2 pg I-TEQ g(-1) for the soil samples. The contributory factors of the varying characteristics of the different areas together with the types of technology adopted at each MSWI plant are discussed. The PCDD/Fs levels are subsequently compared with established values from previous studies.  相似文献   

6.
The concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in plasma samples of 20 nonoccupationally exposed subjects living in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (Catalonia, Spain). The mean PCDD/F value was 27.0 pg I-TEQ/g lipid with a range from 14.8 to 48.9 pg I-TEQ/g lipid. All samples showed higher PCDD than PCDF levels. Although PCDD/F concentrations were higher in women (27.7 pg I-TEQ/g lipid) than in men (25.2 pg I-TEQ/g lipid), the difference was not statistically significant. While a significant correlation (r = 0.565, p < 0.01) between the age of the subjects and the levels of PCDD/F in plasma could be observed, no significant differences were found in relation to the specific residential area. The plasma concentrations of PCDD/F obtained in the current study are discussed and compared with the results of similar investigations reported in the last two years.  相似文献   

7.
Liver of blue shark (Prionace glauca) specimens from the South-Eastern Mediterranean Sea were analyzed for the presence of polychlorinated biphenyls (PCBs), including coplanar congeners, polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). PCBs were the dominant chemicals, followed by PCDFs and PCDDs. The pattern of PCB congener concentrations in the hepatic tissue was dominated by higher chlorinated compounds. The specific profile of toxic PCDD/F congeners was characterized mainly by 2,3,7,8-TCDF and 2,3,7,8-TCDD, followed by 1,2,3,6,7,8-HxCDD and 2,3,4,6,7,8-HxCDF. The total 2,3,7,8-TCDD toxic equivalent (TEQs) was 149 pg g−1 lipid wt. The profile of TEQ shows that PCDDs present the greatest risk to this species contributing to total toxicity with a percentage approximately of 60%, while the contribution of PCDFs and DL-PCBs is almost the same being 22.4% and 21.6%, respectively. Further investigations are urgently needed to characterize the PCDD/Fs contamination levels not only in elasmobranch fish but in all Mediterranean marine biota.  相似文献   

8.
Concentrations of 17 toxic 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) have been determined in pooled samples of breast milk from 15 mothers living in two residential areas (Tarragona downtown and an industrial area) in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (southern Catalonia, Spain). PCDD/Fs in human milk samples ranged between 5.9 and 17.1 pg I-TEQ/g fat (162-498 pg I-TEQ/l), with a mean value of 11.8 pg I-TEQ/g fat (310.8 pg I-TEQ/l). The percentages of fat ranged between 1.53 and 3.52. Although PCDD/F levels in milk from mothers living in the industrial area were found to be slightly higher than those observed in women living Tarragona downtown, most differences did not reach the level of statistical significance. In general terms, PCDD/F concentrations in human milk (pooled) samples of mothers living in the area of Tarragona are similar or lower than those previously reported for most industrialized countries.  相似文献   

9.
BACKGROUND: To observe the relationship between the PCDD/F and Co-PCB levels in samples of human breast milk and nearby waste incinerators in Tokyo, Japan. METHODS: Breast milk was taken from 240 mothers residing in Tokyo, Japan to measure and analyze the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs; 14 congeners), polychlorinated dibenzofurans (PCDFs; 15 congeners), and coplanar polychlorinated biphenyls (Co-PCBs; 12 congeners) contained in the fat. Individual milk samples (about 50 ml) were obtained from the mothers 30 days after delivery, between the months of June and September in 1999 and 2000. A map of Tokyo was used to measure the distances between each mother's place of residence and the closest public and industrial waste incinerators. RESULTS: The distances to the nearest waste incinerators bore no apparent correlations with the congeners of PCDD/Fs and Co-PCBs. The distances were also uncorrelated with the mean toxic equivalent quantities (TEQs) of PCDD/Fs (the sum of PCDDs and PCDFs), Co-PCBs, and the total PCDD/Fs and Co-PCBs. CONCLUSIONS: Although waste incinerators were the largest source of dioxins in Japan at the time of the study, the dioxins levels of mother's milk bore no apparent relationships with the distances between the mothers' domiciles and the nearest waste incinerators. In this study, several meaningful factors were not taken into account, namely, the wind direction, the level of dioxin emitted from each incinerator, the level of environmental pollution of dioxins, and the average time the mothers stayed at home each day. A full understanding of these points awaits future studies.  相似文献   

10.
Over the past decades in China, the number of medical waste incinerators (MWIs) has been rising rapidly, causing emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In this study, samples of fly ash, ash deposits, and bottom ash from typical MWIs were analyzed for PCDD/Fs and their distribution characteristics. Results showed international toxic equivalent (I-TEQ) values in the range of 6.9–67 ng I-TEQ/g in fly ash and ash deposits, whereas the concentration in bottom ash was extremely low (only 1.33 pg I-TEQ/g), yet the generation of PCDD/Fs was mostly de novo synthesis in fly ash and ash deposits according to the ratio of PCDFs to PCDDs; the major distribution differences of PCDD/Fs in fly ash was manifested by the content of toxic furan 2,3,7,8-TCDF, but other toxic PCDD/Fs showed similar distribution. Other findings are that 2,3,4,7,8-PeCDF had the most contribution to TEQ concentration, and that the most abundant toxic furan congener is 1,2,3,4,6,7,8-HpCDF. Correlation analysis showed that there was no significant correlation between PCDD/Fs concentration and several other physical and chemical parameters.

Implications: This paper is of interest because it presents the emission performances of PCDD/Fs in ash from medical waste incineration in China. PCDD/F contents in fly ash and ash deposits vary between 6.9 and 67.3 ng I-TEQ/g. However, the concentration in bottom ash was extremely low (only 1.33?×?10?3 ng I-TEQ/g). The fingerprints of PCDD/Fs in fly ash are almost similar, except for 2,3,7,8-TCDF. There is no marked correlation between PCDD/Fs and other physicochemical properties.

Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

11.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were monitored in stack gas and fly ash of various Korean incinerators and in air samples collected near the facilities. Concentrations of PCDD/Fs in emissions were investigated, and characteristic PCDD/F homologue patterns were classified using statistical analyses. The PCDD/F emission levels in stack gas and fly ash samples from small incinerators (SIs) were higher than those from municipal solid waste incinerators (MSWIs). The PCDD/F concentrations ranged between 0.38 and 1.16 pg I-TEQ/m3 (21.2-75.2 pg/m3) in ambient air samples. The lower-chlorinated furans were the dominant components in most of the stack gas and fly ash samples from SIs, although this was not the case for fly ash from MSWIs. This homologue pattern is consistent with other studies reporting a high fraction of lower-chlorinated furans in most environmental samples affected by incinerator emissions, and it can be used as an indicator to assess the impact of such facilities on the surrounding environment.  相似文献   

12.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

13.
The atmospheric contamination levels of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were evaluated from the analysis of pine needles in South Korea. Pine needles were collected from 30 sampling points at five main cities in South Korea (Busan, Daegu, Gwangju, Changwon and Jeju island). The highest concentrations of PCDDs/DFs (2.19–26.88 pg I-TEQ/g of dry weight) were measured at Busan, where is the city of the highest population density and traffic volume among five cities. The lowest concentration was detected at Jeju with 0.62 pg I-TEQ/g dry weight, suggesting Jeju could be an environmental background area in Korea. The dominant homologues of PCDDs/DFs in pine needles were the lower chlorine-substituted compounds such as tetra CDDs and CDFs, and the distribution ratios of PCDDs/DFs decreased with increase of the number of chlorine substituents. Homologue profiles of pine needle samples were similar to PCDDs/DFs profiles of the vapor phase in the ambient air, and thus the pine needles absorbed the vapor phase of PCDDs/DFs from air. Results suggested that pine needles could be used as an indicator of the atmospheric contamination for PCDDs/DFs in Korea.  相似文献   

14.
Abstract

This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 °C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 μg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 μg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

15.
Emission of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) by municipal solid waste incinerators (MSWI) is an issue of great concern. In 1997, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an MSWI from Tarragona (Catalonia, Spain). As a result, PCDD/F emissions were significantly reduced. The aim of this study was to determine the current levels of PCDD/Fs in soil and vegetation samples collected near the facility and to compare these levels with those obtained in previous surveys (1996 and 1997). In the period 1997-1999, PCDD/F concentrations in vegetation samples were significantly decreased (60%). By contrast, the levels of PCDD/Fs in soil samples increased slightly (14%, P > 0.05) during the same period. An exhaustive analysis of the present data indicates that other emission sources of PCDD/Fs have also a notable environmental impact on the area under direct influence of the MSWI.  相似文献   

16.
Paddy soils and sediments from the Yoneshirogawa, Omonogawa, and Koyoshigawa River Basins in Akita were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The levels and compositions in those samples including soils from non-agricultural areas (non-agricultural soils) were investigated using isomer-specific analysis to determine characteristic sources. The PCDD/PCDF compositions in the samples were compared with respect to possible sources. The PCDD/PCDF concentrations in paddy soils were much higher than those in the non-agricultural soils and much higher than those found in other parts of Japan. Although PCDD/PCDFs were ubiquitous in sediments from river sources to mouths of the respective river basins, those concentrations were much lower than those from paddy soils and non-agricultural soils, and from other parts of Japan. Comparison of PCDD/PCDF homologues and isomer compositions for samples indicated that compositions of paddy soils and sediments, except for those from river sources, had similar characteristics to PCDD/PCDFs originating from impurities in herbicides, 2,4,6-trichlorophenyl 4-nitrophenyl ether (CNP) and pentachlorophenol (PCP), and that compositions of river-source sediments and non-agricultural soils resembled those of atmospheric depositions. Results of statistical analyses suggest that PCDD/PCDF contamination of paddy soils and sediments is attributable mainly to three sources: CNP, PCP, and atmospheric deposition. Results of this study also demonstrate that CNP and PCP are not only important contaminants of local areas of Japan, but that they exist throughout Akita, in northern Japan. We therefore conclude that PCDD/PCDF pollution caused by those compounds has a widespread influence on paddy soils and river sediments in Japan.  相似文献   

17.
Ok G  Ji SH  Kim SJ  Kim YK  Park JH  Kim YS  Han YH 《Chemosphere》2002,46(9-10):1351-1357
The atmospheric contamination levels of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were evaluated from the analysis of pine needles in South Korea. Pine needles were collected from 30 sampling points at five main cities in South Korea (Busan, Daegu, Gwangju, Changwon and Jeju island). The highest concentrations of PCDDs/DFs (2.19–26.88 pg I-TEQ/g of dry weight) were measured at Busan, where is the city of the highest population density and traffic volume among five cities. The lowest concentration was detected at Jeju with 0.62 pg I-TEQ/g dry weight, suggesting Jeju could be an environmental background area in Korea. The dominant homologues of PCDDs/DFs in pine needles were the lower chlorine-substituted compounds such as tetra CDDs and CDFs, and the distribution ratios of PCDDs/DFs decreased with increase of the number of chlorine substituents. Homologue profiles of pine needle samples were similar to PCDDs/DFs profiles of the vapor phase in the ambient air, and thus the pine needles absorbed the vapor phase of PCDDs/DFs from air. Results suggested that pine needles could be used as an indicator of the atmospheric contamination for PCDDs/DFs in Korea.  相似文献   

18.
Estonia still has no waste incineration facilities, which would act as substantial sources of dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) pollution. As landfill fires may serve as sources of dioxins, we focused on the concentrations of PCDD and PCDF in soil samples taken in the vicinity of the landfill located at south-east Estonia in the course of our inventory. Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were studied in five soil samples taken in the vicinity of the Laguja landfill in south-east Estonia. The four soil samples were taken in southern, eastern, western and northern parts not further than 300 m from the landfill, and one sample was taken at the distance of 3 km from the landfill. The PCDD/F concentrations in all soil samples were at background level (0.64-2.33 pg I-TEQ WHO/g dry weight). To maintain this situation, the administrator of the landfill must avoid landfill fires, which are one of the reasons for the generation of dioxins and furans.  相似文献   

19.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

20.
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) were analyzed in samples of the emissions from a secondary aluminum smelter (ALS) and soil samples around the plant. The purpose was to estimate the impact of the emissions on the surrounding environment.PCDD/F soil concentrations were higher in the proximity of the plant, exceeding the limit adopted in Italy in soils for green areas and residential uses and the upper limit of several reference concentrations. The most contaminated sites were less than 500 m from the plant and the dioxin concentration with the distance from the ALS.Principal component analysis (PCA) showed that emissions from the ALS were the source of PCDD/F contamination in the soils closest to the plant. Multivariate data analyses such as PCA are therefore useful to identify sources of emission causing contamination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号