共查询到20条相似文献,搜索用时 0 毫秒
1.
Monitoring of bioaerosol inhalation risks in different environments using a six-stage Andersen sampler and the PCR-DGGE method 总被引:4,自引:0,他引:4
Increasing evidences show that inhalation of indoor bioaerosols has caused numerous adverse health effects and diseases. However, the bioaerosol size distribution, composition, and concentration level, representing different inhalation risks, could vary with different living environments. The six-stage Andersen sampler is designed to simulate the sampling of different human lung regions. Here, the sampler was used in investigating the bioaerosol exposure in six different environments (student dorm, hospital, laboratory, hotel room, dining hall, and outdoor environment) in Beijing. During the sampling, the Andersen sampler was operated for 30 min for each sample, and three independent experiments were performed for each of the environments. The air samples collected onto each of the six stages of the sampler were incubated on agar plates directly at 26 °C, and the colony forming units (CFU) were manually counted and statistically corrected. In addition, the developed CFUs were washed off the agar plates and subjected to polymerase chain reaction (PCR)-denaturing gradient gel electrophoresis (DGGE) for diversity analysis. Results revealed that for most environments investigated, the culturable bacterial aerosol concentrations were higher than those of culturable fungal aerosols. The culturable bacterial and fungal aerosol fractions, concentration, size distribution, and diversity were shown to vary significantly with the sampling environments. PCR-DGGE analysis indicated that different environments had different culturable bacterial aerosol compositions as revealed by distinct gel band patterns. For most environments tested, larger (>3 μm) culturable bacterial aerosols with a skewed size distribution were shown to prevail, accounting for more than 60 %, while for culturable fungal aerosols with a normal size distribution, those 2.1–4.7 μm dominated, accounting for 20–40 %. Alternaria, Cladosporium, Chaetomium, and Aspergillus were found abundant in most environments studied here. Viable microbial load per unit of particulate matter was also shown to vary significantly with the sampling environments. The results from this study suggested that different environments even with similar levels of total microbial cuturable aerosol concentrations could present different inhalation risks due to different bioaerosol particle size distribution and composition. This work fills literature gaps regarding bioaerosol size and composition-based exposure risks in different human dwellings in contrast to a vast body of total bioaerosol levels. 相似文献
2.
Irinel Adriana Badea Lacramioara Axinte Luminita Vladescu 《Environmental monitoring and assessment》2013,185(3):2367-2375
A new HPLC method was developed for the simultaneous determination of aminophenol isomers by means of a mixed-mode stationary phase containing both SCX and C18 moieties. All factors influencing the separation were discussed and optimized. The chromatographic conditions for the separation of aminophenols are the stationary phase duet SCX/C18, the mobile phase of aqueous phosphate buffer (pH 4.85):methanol?=?85:15 (v/v) delivered with a flow rate of 1 mL/min and a detection at 285 nm. The method proposed was validated in terms of linearity, limits of detection and quantification, accuracy and precision. The HPLC method elaborated here was applied with good results on river water samples. In order to survey the quality of surface rivers entered in treatment plants which deliver water for Bucharest, two major rivers were included in a monitoring program which last more than 1 year. 相似文献
3.
Sanyal D Rani A Alam S Gujral S Gupta R 《Environmental monitoring and assessment》2011,180(1-4):97-113
Increased water use associated with rapid growth in the Las Vegas Valley has inadvertently led to the creation of unique wetland systems in Southern Nevada with an abundance of biological diversity. Constructed and naturally created wetlands in the Las Vegas Valley watershed were studied to characterize and understand their potential role for improving ecosystem services (i.e., water purification). Nutrient and metal removal was assessed at four sites including a natural urban runoff wetland, a constructed urban runoff wetland, a constructed wastewater wetland, and a natural urban runoff/wastewater wetland. Plant nutrient uptake was dependent on ambient nutrient concentrations in water and sediments of specific wetlands, irrespective of the type of plants present. Phosphorus was mostly concentrated in below-ground plant parts whereas nitrogen was concentrated in above-ground parts. As for metalloids, bulrushes were more efficient than cattails at taking up arsenic and selenium. Averaging all the wetland sites and plant species, total nitrogen, phosphorus, arsenic and selenium removal was 924.2, 61.5, 0.30, and 0.38 kg/ha/year, respectively. Our findings suggest that natural and created wetland systems can improve water quality in the Las Vegas Valley watershed for some common pollutants, however, other measures are still needed to improve water quality below regulatory thresholds. 相似文献
4.
In this work, the experimental compatibility between the standard DNPH-HPLC method and the gas chromatographic (GC) method (without any derivatization) was investigated for the analysis of atmospheric carbonyls. In the latter case, GC analysis was made based on adsorptive enrichment on solid sorbents followed by thermal desorption. For a comparative analysis between the two methods, we quantified the concentration levels of acetaldehyde from gaseous combustion samples of different charcoal products. The acetaldehyde concentration data, measured by the HPLC method (643 ± 1,689 ppb), were approximately 10% lower than the GC-based method (722 ± 1,788 ppb). As such, the differences in the measured concentrations were statistically insignificant. Although the percentage difference of the two methods fell within a relatively wide range, the results obtained by the GC-based method were comparable to those of the HPLC method with significantly strong correlations. The GC-based method, if tested for certain carbonyl species such as acetaldehyde, appeared to be a suitable alternative for the HPLC method. 相似文献
5.
Organic materials were extracted with acetone from filters of airborne particles by soaking, shaking, soxhletion, and sonication. These extracts were tested with and without S9 for mutagenicity using Ames assay and arabinose-resistant assay of Salmonella typhimurium. Among the extraction methods, soaking extract had the highest mutagenic activity followed by sonication, shaking, and soxhletion in both the assays. With the samples studied, it was concluded that soaking with acetone for 1/2 hr is the simplest and an efficient procedure for the extraction of mutagens from airborne particles.Results of cooperative investigation of NIOSH and West Virginia Agricultural and Forstry Experimental Station. Published with the approval of the Director of the West Virginia Agricultural and Forestry Experiment Station as Scientific Paper No. 1822. 相似文献
6.
萃取-催化氧化光度法测定生物体中H2O2含量研究 总被引:5,自引:0,他引:5
提出萃取-催化氧化光度法测定生物体中H2O2含量的新方法.用稀土催化H2O2产生羟基自由基以氧化二苯基碳酰二肼,生成红色二苯基碳酰腙,其最大吸收波长为563.0nm;当二苯基碳酰二肼浓度一定时,△A563与H2O2含量呈量效关系.在0~30μmol/L H2O2 含量范围内,该法能简单、快速、精确地测定生物样品中H2O2实际含量. 相似文献
7.
Bark samples of spruce, pine and oak trees were collected at two sites in southern Bavaria which are characterized by high agricultural ammonia emissions. The samples were taken using a recently developed bark sampling device which removes a defined layer of the bark. The bark was then analysed for ammonium concentration in order to reflect the environmental ammonia immission. The measured bark concentrations decreased with rising distance between the sample trees and the ammonia source. This applied (i) to measurements inside a closed forest stand ranging from forest edge with high immission to forest interior with much lower immission, and (ii) to the open field where single-standing trees were sampled. Comparing the ammonium concentrations among the three different tree species revealed significant correlations. Thus, it could be shown that old spruce trees are as usable for bark bio-monitoring as the traditionally used pine and oak trees. The ammonium concentrations of the bark were significantly correlated to measurements taken by ammonia passive samplers at the same locations. These results indicate that bark samples may be used for a standardised monitoring of airborne ammonia load. A major advantage of the technique is the determination of the long-term accumulative ammonia load using a single measurement. 相似文献
8.
An analytical method to determine a selection of 27 frequently prescribed and consumed pharmaceuticals in biosolid enriched soils and digested sludges is presented. Using a combination of pressurized liquid extraction, solid phase extraction and liquid chromatography with tandem mass spectrometry, it was possible to detect all analytes in each sample type at the low-sub ng g(-1) level. Solid phase extraction efficiencies were compared for 6 different sorbent types and it was found that Waters Oasis HLB cartridges offered enhanced selectivities with 20 analytes showing final method recoveries > or =60% in both soils and digested sludges. The method was validated for linearity, range, precision and limits of detection in both sample matrices. All analytes were then determined in sludge enriched soils as well as the precursor thermally dried sludge fertilizer produced from a primary wastewater treatment plant. Levels of the antibacterial agent triclosan were found to exceed 20 microg g(-1) in digested sludge and 5 microg g(-1) in thermally dried sludge cake. Significant traces of carbamazepine and warfarin were also detected in the above samples. 相似文献
9.
10.
利用Triolein-半渗透膜采样技术测定淮河水中的有毒有机污染物 总被引:5,自引:1,他引:5
利用 Triolein 半渗透膜采样技术 ( Triolein SPMD)采集了淮河信阳、淮南断面水样 ,测定了采样器中多氯联苯、多环芳烃、取代苯等有毒有机污染物浓度。污染物在 SPMD酯中高浓度富集 ,使其定性和定量更加容易和准确。根据SPMD酯 水分配平衡理论 ,进一步估算得到目标污染物在水中的平均浓度。本研究证明 Triolein SPMD技术可用于水中多氯联苯、多环芳烃、取代苯等污染物的采集和定量分析 ,可在我国的优先污染物监测、控制工作中发挥作用。 相似文献
11.
Quantification of penoxsulam in soil and rice samples by matrix solid phase extraction and liquid-liquid extraction followed by HPLC-UV method 总被引:1,自引:0,他引:1
Pervinder Kaur Khushwinder Kaur M. S. Bhullar 《Environmental monitoring and assessment》2014,186(11):7555-7563
The paper exploits the development of novel, simple and sensitive methodology involving matrix solid phase dispersion (MSPD) and the comparison of MSPD with liquid-liquid extraction (LLE) for the evaluation of residual penoxsulam in soil and rice samples. Extracted samples were analyzed by high-performance liquid chromatography (HPLC) with ultraviolet detector at 230 nm. Both methods were optimized, considering different parameters, and under optimum conditions, the mean recoveries obtained were in the range of 85–104 % for MSPD and 78.8–90.7 % for LLE. Precision values expressed as relative standard deviation (RSD) were ≤10 for MSPD and ≤15 for LLE. Linearity for penoxsulam was in the range of 0.01–20 μg mL?1 with limits of detection and limits of quantification of 0.01 and 0.03 mg kg?1, respectively. 相似文献
12.
Cronin JP Agrawal A Adams L Tonazzi JC Brisson MJ White KT Marlow D Ashley K 《Journal of environmental monitoring : JEM》2008,10(8):955-960
Analytical methods for the determination of trace beryllium in soils are needed so that anthropogenic sources of this element can be distinguished from native (background) levels of beryllium. In this work, a collaborative interlaboratory evaluation of a new extraction and fluorescence-based procedure for determining beryllium in soil samples was carried out to fulfil method validation requirements for ASTM International voluntary consensus standard test methods. A Canadian reference material, CCRMP Till-1 soil, with a background beryllium concentration of 2.4 microg g(-1), was selected for study. This certified reference material (CRM) was spiked and homogenized with varying levels of beryllium oxide in order to give batches of material with beryllium concentrations of 4.36 +/- 0.69, 11.5 +/- 0.7, 124 +/- 7 and 246 +/- 16 microg g(-1) (+/- values are standard deviations). In the interlaboratory study (ILS), which was carried out in accordance with an applicable ASTM International standard practice (ASTM E691), samples of these spiked soils were subjected to extraction in dilute ammonium bifluoride at approximately 90 degrees C for 40 h. Fluorescence measurement of the extracted beryllium was carried out via detection using the high quantum yield fluorophore, hydroxybenzoquinoline sulfonate (HBQS). Interlaboratory precision estimates from six participating laboratories ranged from 0.048 to 0.103 (relative standard deviations) for the five different beryllium concentrations. Pooled bias estimates resulting from this ILS were between -0.049 and 0.177 for the various beryllium levels. These figures of merit support promulgation of the analytical procedure as an ASTM International standard test method. 相似文献
13.
Illegal dumping of polychlorinated biphenyl (PCB) capacitors was discovered in Kobe, Japan, in 2001, leaving about 68 m(3) (92 tons) of soil contaminated with approximately 6.6 kg of PCBs. Solvent extraction technology carried out in 2002-2003 using isopropyl alcohol remedied the affected soil at the site. Forty-seven batch treatments were conducted during full-scale treatment. On average, 8.4 extraction cycles per batch were needed to achieve the clean-up goal for PCBs (i.e., the Japanese environmental quality standard for soil). Analytical results showed that the average PCB concentration (88 microg g(-1)-dry soil) in untreated soil samples of all the batches was decreased to 1.2 microg g(-1)-dry soil in treated soil samples, yielding a removal efficiency of 98.6%. Dioxin responsive-chemical activated luciferase gene expression assay (DR-CALUX) and enzyme-linked immunosorbent assay (ELISA) adopting a monoclonal antibody against 2,3',4,4',5-pentachlorobiphenyl (PCB #118) were used to rapidly screen soil samples before and after solvent extraction. The DR-CALUX and ELISA results were in good agreement with World Health Organization toxicity equivalent values and analytically determined PCB concentrations, respectively. Regular monitoring during the treatment period confirmed that the applied technology met Japanese environmental and control regulations concerning treatment and disposal of contaminated soils and treatment residues. After full-scale treatment, the amount of PCBs recovered from the solvent purification system approximated the estimated amount of PCBs spilled. 相似文献
14.
Hallare AV Gervasio MK Gervasio PL Acacio-Claro PJ 《Environmental monitoring and assessment》2009,156(1-4):331-341
Some types of occupations involve high levels of exposure to potentially genotoxic gaseous and particulate substances from internal combustion engines used in motor vehicles. These occupational exposures may contribute to the development of many illnesses, usually through chromosomal change mechanisms that include strand breakage, deletions, sister chromatid exchange and non-disjunction. To determine the effect of occupational exposure in gasoline station attendants and traffic enforcers, the micronucleus test was used. Exfoliated oral mucosa cells from 18 gasoline station attendants, 18 traffic enforcers and 18 control subjects in the City of Manila were examined for micronucleated cell (MNC) frequency. Analysis of buccal cells showed that MNC frequencies in exposed individuals were significantly greater than in control subjects (p < or = 0.05). However, between gasoline station attendants and traffic enforcers, MNC frequencies of the two exposed groups exhibited no significant difference. No relation was also found between MNC frequency and any of the factors such as age, smoking habits, alcohol habits and working period. This was further confirmed in the multiple regression analysis which showed that only occupational exposure was a good predictor of MNC frequency. The results of this study suggest that gasoline station attendants and traffic enforcers, compared to the control individuals, are at a greater risk of chromosomal damage. For the assessment of chromosomal damage, the study, development, and standardization of tests are recommended for public institutions concerned with matters regarding environmental quality and community health. 相似文献
15.
Bernd Lengers Inga Schiefler Wolfgang Büscher 《Environmental monitoring and assessment》2013,185(12):9751-9762
The overall measurement of farm level greenhouse gas (GHG) emissions in dairy production is not feasible, from either an engineering or administrative point of view. Instead, computational model systems are used to generate emission inventories, demanding a validation by measurement data. This paper tests the GHG calculation of the dairy farm-level optimization model DAIRYDYN, including methane (CH4) from enteric fermentation and managed manure. The model involves four emission calculation procedures (indicators), differing in the aggregation level of relevant input variables. The corresponding emission factors used by the indicators range from default per cow (activity level) emissions up to emission factors based on feed intake, manure amount, and milk production intensity. For validation of the CH4 accounting of the model, 1-year CH4 measurements of an experimental free-stall dairy farm in Germany are compared to model simulation results. An advantage of this interdisciplinary study is given by the correspondence of the model parameterization and simulation horizon with the experimental farm’s characteristics and measurement period. The results clarify that modeled emission inventories (2,898, 4,637, 4,247, and 3,600 kg CO2-eq. cow?1 year?1) lead to more or less good approximations of online measurements (average 3,845 kg CO2-eq. cow?1 year?1 (±275 owing to manure management)) depending on the indicator utilized. The more farm-specific characteristics are used by the GHG indicator; the lower is the bias of the modeled emissions. Results underline that an accurate emission calculation procedure should capture differences in energy intake, owing to milk production intensity as well as manure storage time. Despite the differences between indicator estimates, the deviation of modeled GHGs using detailed indicators in DAIRYDYN from on-farm measurements is relatively low (between ?6.4 % and 10.5 %), compared with findings from the literature. 相似文献
16.
Brown RJ Kumar Y Brown AS Dexter MA Corns WT 《Journal of environmental monitoring : JEM》2012,14(2):657-665
The manual and semi-automatic methods for the measurement of total gaseous mercury in ambient air have been compared in a field trial for the first time. The comparison results have shown that whilst the expected random scatter is present, there was no significant systematic bias between the two methods, whose operational differences have also been outlined and analysed in this work. Furthermore it has been observed that because variation in instrument sensitivity is largely random in nature there is little effect on the results of the comparison if the period between instrument calibrations is altered. When the manual and semi-automatic methods are compared according to guidelines produced by the European Commission the results presented here, taken together with other supporting evidence, strongly suggest that the two methods are equivalent. 相似文献
17.
On-site measurement of lead in workplace air filter samples and paint chip samples by ultrasonic extraction and anodic stripping voltammetry (UE-ASV) was evaluated in the field during renovation and remodeling activities in residences having leaded paint. Aerosol and paint samples were collected using standard techniques, and the samples were analyzed on-site for lead content by portable UE-ASV. Lead in sample extracts was subsequently determined by atomic absorption (AA) spectrometry in a fixed-site laboratory. The remaining sample extracts plus undissolved material (air filters or paint particles) were then subjected to hot plate digestion in concentrated nitric acid-30% hydrogen peroxide prior to AA analysis for lead. Field UE-ASV lead data were thereby compared to UE-AA and hot plate digestion-AA results from fixed-site laboratory lead measurement. Determination of lead in air filter samples by UE-ASV (over the range of 5 microg to approximately 800 microg Pb per sample) was extremely well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, a significant negative bias associated with ASV measurement was observed, and this was attributed to a matrix effect. Lead measurement in paint chip samples by UE-ASV (over the range of approximately 10 to approximately 550 microg Pb g(-1)) was well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, correlation and precision were lower for lead measurement in paint samples as compared to aerosol samples, and a negative bias was also observed. Lead measurements by UE-AA were compared to lead determinations by hot plate digestion-AA; these data were highly correlated and demonstrated no significant bias. Thus it was concluded that the ultrasonic extraction procedure performed equivalently to hot plate digestion. It was reasoned that matrix effects due to the preparation and analysis of paint chip particles resulted in greater imprecision as well as negative bias by ASV measurement. Despite significant negative bias in this sample set, UE-ASV offers promise for on-site measurement of lead in samples of interest in occupational and environmental health. 相似文献
18.
Jasmin Shah M. Rasul Jan Farhat-un-nisa Shehzad Behisht Ara 《Environmental monitoring and assessment》2011,175(1-4):103-108
A method for the residual pendimethalin in soil and vegetable samples was developed. The method is based on extraction of pendimethalin from samples using microwave-assisted solvent extraction (MASE) with acetone, ethanol, and water as extraction solvent. Extracted pendimethalin samples were analyzed by high-performance liquid chromatography with ultraviolet detector at 240 nm. The MASE parameters, temperature, heating time, and solvent types were optimized with the feasibility of MASE application in the determination of pendimethalin extraction efficiency of pendimethalin from soil and vegetable samples. The maximum temperature that can be used during the heating for MASE is 60°C, where the recovery percentages reached 97%. Linearity for pendimethalin was found in the range of 2?C20 ??g mL???1 with limits of detection and limits of quantification of 0.059 and 0.17 ??g mL???1, respectively. 相似文献
19.
Creed PA Gallawa CM Young AR Schwegel CA Lytle D Sorg TJ Creed JT 《Journal of environmental monitoring : JEM》2006,8(9):968-972
A sequential extraction approach was utilized to estimate the distribution of arsenite [As(iii)] and arsenate [As(v)] on iron oxide/hydroxide solids obtained from drinking water distribution systems. The arsenic (As) associated with these solids can be segregated into three operationally defined categories (exchangeable, amorphous and crystalline) according to the sequential extraction literature. The exchangeable As, for the six drinking water solids evaluated, was estimated using 10 mM MgCl(2) and 10 mM NaH(2)PO(4) and represented between 5-34% of the total As available from the solid. The amorphously bound As was estimated using 10 mM (NH(4))(2)C(2)O(4) and represented between 57-124% of the As available from the respective solid. Finally, the crystalline bound As was estimated using titanium citrate and this represented less than 1.5% of the As associated with the solids. A synthetic stomach/intestine extraction approach was also applied to the distribution solids. The stomach fluid was found to extract between 0.5-33.3 microg g(-1) As and 120-2,360 microg g(-1) iron (Fe). The As concentrations in the intestine fluid were between 0.02-0.04 microg g(-1) while the Fe concentration ranged from 0.06-0.7 microg g(-1) for the first six drinking water distribution solids. The elevated Fe levels associated with the stomach fluid were found to produce Fe based precipitates when the intestinal treatment was applied. Preliminary observations indicate that most of the aqueous Fe in the stomach fluid is ferric ion and the observed precipitate produced in the intestine fluid is consistent with the decreased solubility of ferric ion at the pH associated with the intestine. 相似文献
20.
Roy Pöllänen 《Environmental monitoring and assessment》1993,28(3):239-254
The possibility has been investigated of using the PIXE method to yield long and reliable time series for indicating changes in the environment, with moths or butterflies as a sample target. The suitability of this approach was demonstrated by studying standard deviations of measurements of single moths and those of populations of moths. The properties of targeting at different anatomical sites were investigated and the wing gave the most stable results, perhaps because its metabolic development is completed at the imago (newborn butterfly) stage. According to test measurements of different populations it seems possible to use moth or butterfly wing measurements to study environmental changes over the past century or so using moth or butterfly collections. 相似文献