共查询到20条相似文献,搜索用时 0 毫秒
1.
Healthcare settings present a challenging environment for assessing low-level concentrations of specific volatile organic compounds (VOCs) in the presence of high background concentrations of alcohol from the use of hand sanitizers and surface disinfectants. The purposes of this laboratory-based project were to develop and validate a sampling and analysis methodology for quantifying low-level VOC concentrations as well as high-level alcohol concentrations found together in healthcare settings. Sampling was conducted using evacuated canisters lined with fused silica. Gas chromatography/mass spectrometry analysis was performed using preconcentration (for ppb levels) and loop injection (for ppm levels). For a select list of 14 VOCs, bias, precision, and accuracy of both the preconcentration and loop injection methods were evaluated, as was analyte stability in evacuated canisters over 30 days. Using the preconcentration (ppb-level) method, all validation criteria were met for 13 of the 14 target analytes-ethanol, acetone, methylene chloride, hexane, chloroform, benzene, methyl methacrylate, toluene, ethylbenzene, m,p-xylene, o-xylene, alpha-pinene, and limonene. Using the loop injection (ppm-level) method, all validation criteria were met for each analyte. At ppm levels, alpha-pinene and limonene remained stable over 21 days, while the rest of the analytes were stable for 30 days. All analytes remained stable over 30 days at ppb levels. This sampling and analysis approach is a viable (i.e., accurate and stable) methodology that will enable development of VOC profiles for mixed exposures experienced by healthcare workers. 相似文献
2.
Daughtrey EH Oliver KD Adams JR Kronmiller KG Lonneman WA McClenny WA 《Journal of environmental monitoring : JEM》2001,3(1):166-174
A carefully designed study was conducted during the summer of 1998 to collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. Thirty-two 1 h sample sets were taken, each composed of a "near-real-time" sample analyzed by an autoGC-MS XonTech 930/Varian Saturn 2000 system, and Summa and Silco canisters. Hourly total non-methane organic carbon (TNMOC), ozone, and meteorological measurements were also made. Each canister was analyzed on the autoGC-MS system for a target list of 108 volatile organic compounds (VOCs) and on a manual cryosampling GC-FID system. Comparisons were made between the collection and analysis methods. Because of the low sample loading (150-250 ppbC TNMOC), these comparisons were a stringent test of sample collection and analysis capabilities. The following specific conclusions may be drawn from this study. Reasonable precision (within 15% mean difference of duplicate analyses from the same canister) can be obtained for analyses of target VOCs at low-ppbC concentrations. Relative accuracy between the GC-MS and GC-FID analysis methods is excellent, as demonstrated by comparisons of analyses of the same canisters, if measurements are sufficiently above the detection limits. This is especially significant as the GC-MS and GC-FID were independently calibrated. While statistically significant differences may be observed between the results from canister and near-real-time samples, the differences were generally small and there were clear correlations between the canister results and the near-real-time results. Canister cleanliness limits detection below the EPA Method TO-14 acceptance standard of 0.2 ppbv (0.2-2 ppbC for target analytes). 相似文献
3.
E. Wauters E. Walravens E. Muulle G. Verduyn 《Environmental monitoring and assessment》1983,3(2):151-160
This study deals with the evaluation of a fast method for sampling of volatile organic compounds in ambient air. Special bags made of an inert material are used together with a large handpump which allows a sampling of one liter per second. After the sampling, the pollutants are concentrated by adsorption on Tenax and transfered by heat desorption, to a small capillary precolumn cooled with liquid nitrogen, or directly trapped on the precolumn. The suitability of this technique was evaluated by sampling complex synthetic mixtures of known concentration and composition, after which the samples were submitted to a series of operations such as transport, aging, changing of the humidity, heating and cooling, irradiation, etc. Changes in the original mixtures, caused by adsorption, diffusion, chemical or photochemical reactions were investigated by GC-MS analysis. The results of the study show that under certain conditions the samples can be preserved for a rather long period of time without noticeable changes in composition. However for certain compounds, severe quantitative losses occur after one day storage. Finally a practical application of this method is described in a recent case of strong odour annoyance by a chemical plant in the north of Belgium. 相似文献
4.
A canister-based 1 week sampling method using a mechanical flow controller and a 6 L fused-silica-lined canister was evaluated for the long-term measurement of 47 VOCs in ambient air at pptv (volume/volume) to ppbv levels by use of a three-stage preconcentation method followed by GC-MS analysis. The GC conditions were initially optimized for complete separations of several pptv-level VOCs (e.g. vinyl chloride, 1,3-butadiene, acrylonitrile, 1,2-dichloroethane and chloroform) in ambient air because the selected ions are easily interfered with by coexisting C4-, C5-hydrocarbons and analytes presented at ppbv levels. Thirty-four VOCs determined by the 1 week and 24 h sampling method in December 16-22 (2002) had concentrations of 6.0-15000 pptv per compound. Concentrations of 28 VOCs (including polar VOCs (e.g. methyl isobutyl ketone and butyl acetate)) obtained by the method were approximately equal to the mean values calculated from 24 h sampling (< +/- 10% deviation). Six VOCs that had low concentrations of 6.0-43 pptv showed more than +/- 10% deviation. Thirteen VOCs were not detected during the entire sampling period. The effect of relative humidity or ozone for the specific VOCs (e.g. MIBK, butyl acetate, vinyl chloride, 1,3-butadiene and styrene) was negligible. 相似文献
5.
A dual channel gas chromatograph with flame ionisation detectors has been used extensively for analysis of volatile organic compounds in the atmosphere and forms the basis of two monitoring instruments contributing VOC data to the World Meteorological Organisation - Global Atmosphere Watch network. Recent modifications to the methodology have broadened the scope of the instrument; to incorporate measurements of selected monoterpenes, and achieve improved accuracy in the measurement of oxygenated volatile organic compounds. Analysis of selected monoterpenes has been achieved without any significant loss of resolution of the non-methane hydrocarbons or oxygenated compounds. Quantification of 64 different VOCs of varying functionalities are reported with detection limits in the range 1-5 parts per trillion. Here we present a summary of the instrumental and calibration details for the methodology, which continues to be used on many field projects, along with a discussion of the associated measurement uncertainties. 相似文献
6.
Glas B Stenberg B Stenlund H Sunesson AL 《Journal of environmental monitoring : JEM》2008,10(11):1297-1303
This article addresses problems that complicate attempts to compare methods when several factors may be associated with an effect, but it is not known which factors are relevant. Chemicals that may contribute to 'sick building syndrome' (SBS), and thus should be sampled in investigations of SBS, are not currently known. A study was undertaken to compare the utility of three adsorbents (Carbopack B, Chromosorb 106 and Tenax TA) for detecting differences in personal chemical exposure to volatile organic compounds in indoor air, between persons with and without SBS symptoms (cases and controls). On the basis of office workers' responses to a questionnaire, 15 cases and 15 controls were chosen. They simultaneously carried diffusive samplers with adsorbents during a week at work, and the acquired samples were analysed by gas chromatography/mass spectrometry (GC/MS). The adsorbents were then compared in terms of their ability to separate cases and controls in partial least square discriminant analysis (PLS-DA) models. This method of comparison takes into account detected differences in chemical exposure between cases and controls measured with the different adsorbents. Tenax TA gave the best PLS-DA models for separating cases and controls, but a combination of measurements with Tenax TA and Carbopack B gave better PLS-DA models than models based on measurements from either adsorbent alone. Adding measurements from Chromosorb 106 did not improve the results. 相似文献
7.
Air sampling, using sorbents, thermal desorption and gas chromatography, is a versatile method for identifying and quantifying trace levels of volatile organic compounds (VOCs). Thermal desorption can provide high sensitivity, appropropriate choices of sorbents and method parameters can accommodate a wide range of compounds and high humidity, and automated short-path systems can minimize artifacts, losses and carry-over effects. This study evaluates the performance of a short-path thermal desorption method for 77 VOCs using laboratory and field tests and a dual sorbent system (Tenax GR, Carbosieve SIII). Laboratory tests showed that the method requirements for ambient air sampling were easily achieved for most compounds, e.g., using the average and standard deviation across target compounds, blank emissions were < or = 0.3 ng per sorbent tube for all target compounds except benzene, toluene and phenol; the method detection limit was 0.05 +/- 0.08 ppb, reproducibility was 12 +/- 6%, linearity, as the relative standard deviation of relative response factors, was 16 +/- 9%, desorption efficiency was 99 +/- 28%, samples stored for 1-6 weeks had recoveries of 87 +/- 9%, and high humidity samples had recoveries of 102 +/- 12%. Due to sorbent, column and detector characteristics, performance was somewhat poorer for phenol groups, ketones, and nitrogen containing compounds. The laboratory results were confirmed in an analysis of replicate samples collected in two field studies that sampled ambient air along roadways and indoor air in a large office building. Replicates collected under field conditions demonstrated good agreement except for very low concentrations or large (> 41 volume) samples of high humidity air. Overall, the method provides excellent performance and satisfactory throughput for many applications. 相似文献
8.
A new method of determining the composition of sediment/soil gases and their volatile organic compound (VOC) content is described. VOCs were collected in situ from intertidal sediments in the Menai Strait and surrounding areas. The sampling was performed using a portable sampler comprising a funnel coupled to a SPME fibre. Gases were extracted from the sediments using a small vacuum pump pulling 100 mL min(-1) at atmospheric pressure. Sixty one different compounds were detected in the samples, and their fluxes and concentrations were determined. The compounds were classified into groups: halogenated, sulfur containing compounds, aldehydes, BTEXs (benzene, toluene, ethyl benzene and xylene) and aliphatic hydrocarbons. Results of principal component analysis (PCA) showed that the chemical composition of extracted gas was influenced primarily by sediment type. Muddy anoxic sediments were dominated by halogenated and sulfur containing compounds and sandy sediments had more aldehydes and BTEXs. 相似文献
9.
The interest in the identification of volatile organic compounds in the workplace has been a major focus of many National Institute for Occupational Safety and Health (NIOSH) field studies. A primary technique for sampling and analysis of these compounds is summarized by NIOSH Manual of Analytical Methods (NMAM) 2549. This is a screening method that uses a multi-bed sorbent to trap a wide variety of compounds and compound classes. Thermal desorption techniques are used as a first attempt to characterize potential contaminants in a workplace and to determine what future sampling and analyses must be performed. Field examples are provided to show the versatility of thermal desorption methods and techniques. Due to their sensitivity, thermal desorption tube methods are sometimes required in order to measure the workplace concentrations of unusual compounds. In other situations, the exposures are too high or varied to make thermal desorption tubes practical. In these cases, the identification of contaminants with thermal desorption tubes leads to new method developments for the quantification of specific compounds using more conventional solid sorbent-solvent desorption based methods. 相似文献
10.
Determination of volatile organic compounds pollution sources in malaysian drinking water using multivariate analysis 总被引:1,自引:0,他引:1
A field investigation was conducted at all water treatment plants throughout 11 states and Federal Territory in Peninsular
Malaysia. The sampling points in this study include treatment plant operation, service reservoir outlet and auxiliary outlet
point at the water pipelines. Analysis was performed by solid phase micro-extraction technique with a 100 μm polydimethylsiloxane
fibre using gas chromatography with mass spectrometry detection to analyse 54 volatile organic compounds (VOCs) of different
chemical families in drinking water. The concentration of VOCs ranged from undetectable to 230.2 μg/l. Among all of the VOCs
species, chloroform has the highest concentration and was detected in all drinking water samples. Average concentrations of
total trihalomethanes (THMs) were almost similar among all states which were in the range of 28.4--33.0 μg/l. Apart from THMs,
other abundant compounds detected were cis and trans-1,2-dichloroethylene, trichloroethylene, 1,2-dibromoethane, benzene, toluene, ethylbenzene, chlorobenzene, 1,4-dichlorobenzene
and 1,2-dichloro - benzene. Principal component analysis (PCA) with the aid of varimax rotation, and parallel factor analysis
(PARAFAC) method were used to statistically verify the correlation between VOCs and the source of pollution. The multivariate
analysis pointed out that the maintenance of auxiliary pipelines in the distribution systems is vital as it can become significant
point source pollution to Malaysian drinking water. 相似文献
11.
Chiung-Yu Peng Sheng-Ling Hsiao Cheng-Hang Lan Yu-Li Huang 《Environmental monitoring and assessment》2013,185(1):181-196
The objectives of this study are to investigate the volatile organic compound (VOC) distribution using passive samplers and to assess the resulting health risks in a high-tech science industrial park. With the advantages of passive sampling techniques, long-term and wide-area samples are collected. The results show TVOC concentrations in summer, fall, winter, and spring are 7.14?±?5.66 ppb, 18.17?±?5.81 ppb, 10.30?±?3.54 ppb, and 14.56?±?4.53 ppb, respectively; those on weekdays and weekends are 14.36?±?6.80 ppb and 9.87?±?4.86 ppb, respectively; and those in industrial and residential zones are 12.97?±?0.39 ppb and 11.13?±?0.68 ppb, respectively. Based on concentration variations, and benzene, toluene, ethylbenzene, and xylene ratios, we can resolve the source origins. Health risks are assessed based on the resulting concentrations. In the case of non-cancer chronic effects, long-term exposure to these concentrations does not support there is a risk of adverse health effects. However, potential cancer risks of exposure to these concentrations may occur, especially to carbon tetrachloride and benzene. By applying this study’s procedures, information on VOC concentration distribution, source identification, and health assessment can be obtained and they are applicable to similar studies. 相似文献
12.
Phan NT Kim KH Jeon EC Kim UH Sohn JR Pandey SK 《Environmental monitoring and assessment》2012,184(3):1683-1692
A number of volatile organic compounds (VOCs) including acetone, methyl ethyl ketone, toluene, ethylbenzene, m,p-xylene, styrene, and o- xylene released during food decaying processes were measured from three types of decaying food samples (Kimchi (KC), fresh
fish (FF), and salted fish (SF)). To begin with, all the food samples were contained in a 100-mL throwaway syringe. These
samples were then analyzed sequentially for up to a 14-day period. The patterns of VOC release contrasted sharply between
two types of fish (FF and SF) and KC samples. A comparison of data in terms of total VOC showed that the mean values for the
two fish types were in the similar magnitude with 280 ± 579 (FF) and 504 ± 1,089 ppmC (SF), while that for KC was much lower
with 16.4 ± 7.6 ppmC. There were strong variations in VOC emission patterns during the food decaying processes between fishes
and KC that are characterized most sensitively by such component as styrene. The overall results of this study indicate that
concentration levels of the VOCs differed significantly between the food types and with the extent of decaying levels through
time. 相似文献
13.
Shippi Dewangan Rajan Chakrabarty Barbara Zielinska Shamsh Pervez 《Environmental monitoring and assessment》2013,185(11):9279-9286
Worshipping activity is a customary practice related with many religions and cultures in various Asian countries, including India. Smoke from incense burning in religious and ritual places produces a large number of health-damaging and carcinogenic air pollutants include volatile organic compounds (VOCs) such as formaldehyde, benzene, 1,3 butadiene, styrene, etc. This study evaluates real-world VOCs emission conditions in contrast to other studies that examined emissions from specific types of incense or biomass material. Sampling was conducted at four different religious places in Raipur City, District Raipur, Chhattisgarh, India: (1) Hindu temples, (2) Muslim graveyards (holy shrines), (3) Buddhist temples, and (4) marriage ceremony. Concentrations of selected VOCs, respirable particulate matter (aerodynamic diameter, <5 μm), carbon dioxide, and carbon monoxide were sampled from the smoke plumes. Benzene has shown highest emission factor (EF) among selected volatile organic compounds in all places. All the selected religious and ritual venues have shown different pattern of VOC EFs compared to laboratory-based controlled chamber studies. 相似文献
14.
Investigation and assessment of volatile organic compounds in water sources in China 总被引:1,自引:0,他引:1
456 water samples collected from 152 water sources in 2006 were analyzed for 21 volatile organic compounds (VOCs). Concentrations of 21 VOCs ranged from below method detection limits of the laboratory to 7.65 ??g/L (toluene), but seldom exceeded the concentration limits set in the National Drinking Water Quality Standards (GB5749-2006) or the National Environmental Quality Standards for Surface Water (GB3838-2002) of China. Of the 21 individual VOCs analyzed, 11 VOCs were detected in at least one sample at or above 1.0 ??g/L; 6.6% of the water samples had a detection of at least one VOC at or above 1.0 ??g/L, and 2.6% had a detection of at least two VOCs at or above 1.0 ??g/L. Based on the statistical data of detection frequencies above the method detection limits, 75% of the samples detected at least one VOC, and 65% of the samples detected at least two VOCs. Chloroform, toluene, and 1,2-dichloroethene were the three most frequently detected VOCs, with detection frequencies of 76.97%, 68.42%, and 44.08%, respectively. Volatile halogenated hydrocarbons and gasoline components were the two most frequently detected VOC groups. 相似文献
15.
Exposure to vapours of volatile chemicals is a major occupational and environmental health concern. Toxicity testing of volatile organic compounds (VOCs) has always faced significant technological problems due to their high volatility and/or low solubility. The aim of this study was to develop a practical and reproducible in vitro exposure technique for toxicity testing of VOCs. Standard test atmospheres of xylene and toluene were generated in glass chambers using a static method. Human cells including: A549-lung derived cell lines, HepG2-liver derived cell lines and skin fibroblasts, were grown in porous membranes and exposed to various airborne concentrations of selected VOCs directly at the air/liquid interface for 1 h at 37 degrees C. Cytotoxicity of test chemicals was investigated using the MTS (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium) and NRU (neutral red uptake) assays following 24 h incubation. Airborne IC(50) (50% inhibitory concentration) values were determined using dose response curves for xylene (IC(50)=5350+/- 328 ppm, NRU; IC(50)=5750+/- 433 ppm, MTS in skin fibroblast) and toluene (IC(50)=0 500+/- 527 ppm, NRU; IC(50)=11,200 +/- 1,044 ppm, MTS in skin fibroblast). Our findings suggest that static direct exposure at the air/liquid interface is a practical and reproducible technique for toxicity testing of VOCs. Further, this technique can be used for inhalational and dermal toxicity studies of volatile chemicals in vitro as the exposure pattern in vivo is closely simulated by this method. 相似文献
16.
Solbu K Hersson M Thorud S Lundanes E Nilsen T Synnes O Ellingsen D Molander P 《Journal of environmental monitoring : JEM》2010,12(5):1195-1202
Suddenly occurring and time limited chemical exposures caused by unintended incidents might pose a threat to many workers at various work sites. Monitoring of exposure during such occasional incidents is challenging. In this study a compact, low-weight and personal semi-automatic pumped unit for sampling of organic vapor phase compounds from occupational air during sporadic and suddenly occurring incidents has been developed, providing simple activation by the worker potentially subjected to the sudden occurring exposures when a trained occupational hygienist is not available. The sampler encompasses a tube (glass or stainless steel) containing an adsorbent material in combination with a small membrane pump, where the adsorbent is capped at both ends by gas tight solenoid valves. The sampler is operated by a conventional 9 V battery which tolerates long storage time (at least one year), and is activated by pulling a pin followed by automatic operation and subsequent closing of valves, prior to shipping to a laboratory. The adjustable sampling air flow rate and the sampling time are pre-programmed with a standard setting of 200 mL min(-1) and 30 min, respectively. The average airflow in the time interval 25-30 min compared to average airflow in the interval 2-7 min was 92-95% (n = 6), while the flow rate between-assay precisions (RSD) for six different samplers on three days each were in the range 0.5-3.7%. Incident sampler recoveries of VOCs from a generated VOC atmosphere relative to a validated standard method were between 95 and 102% (+/-4-5%). The valves that seal the sampler adsorbent during storage have been shown to prevent an external VOC atmosphere (500 mg m(-3)) to enter the adsorbent tube, in addition to that the sampler adsorbent is storable for at least one month due to absence of ingress of contaminants from internal parts. The sampler was also suitable for trapping of semi-volatile organophosphates. 相似文献
17.
Marta Doval Mi?arro Isabel María Morales Terrés Jose A. Egea Enrique González Ferradás Agustín Mi?ana Aznar 《Environmental monitoring and assessment》2012,184(12):7353-7364
Diffusive samplers were used to measure the vertical concentrations of benzene, toluene, n-hexane, cyclohexane, ethylbenzene and o-, m- and p-xylenes on both sides of two NS-oriented street canyons in Murcia (Spain) during a 5-day period. Non-dimensional relationships of concentration and height were calculated in order to study the behaviour of their concentration vertical profiles. The results show that the vertical profiles of benzene, toluene, n-hexane and cyclohexane concentrations were similar in both streets and on both sides of each street. Some differences were found in vertical profiles between streets and sides for ethylbenzene and xylenes, probably due to their higher affinity for adsorption into building materials. The similarities found for the first set of VOCs suggest that the dynamics of the dispersion was the same for both streets and was mainly influenced by microscale thermal effects. Finally, the concentration measurements of benzene, toluene, n-hexane, cyclohexane, and ethylbenzene were adjusted to expressions in the form c?=?c 0(h/h 0) A , and a regression coefficient R 2?=?0.962 (p?=?0.0000) was obtained. The decreasing concentration of these compounds with height should be taken into account when assessing population exposure to these pollutants. 相似文献
18.
Comprehensive screening and priority ranking of volatile organic compounds in Daliao River,China 总被引:1,自引:0,他引:1
Huilian Ma Haijun Zhang Longxing Wang Jincheng Wang Jiping Chen 《Environmental monitoring and assessment》2014,186(5):2813-2821
An analytical strategy for comprehensive screening of target and non-target volatile organic compounds (VOCs) in surface water was developed, and it was applied to the analysis of VOCs in water samples from Daliao River. The target VOCs were quantified using purge and trap-gas chromatography-mass spectrometry (P&T-GC/MS). Among 20 water samples, 34 VOCs were detected at least once. For the screening of non-target VOCs, the double distillation apparatus was used for the pre-concentration of VOCs prior to P&T-GC/MS analysis. Subsequently, deconvolution software and NIST mass spectral library were applied for the identification of the non-target compounds. A total of 17 non-target VOCs were identified. The most frequently detected VOCs (detection frequencies >80 %) included toluene, benzene, naphthalene, 1,2-dichloroethane, 1,1,2-trichloroethane, and methyl tert-butyl ether. The distribution of VOCs obviously varied according to the sampling sites. The total concentrations of VOCs in water samples collected from the heavily industrialized cities (Anshan and Liaoyang) and the busy port city (Yingkou) were relatively high. The top ten priority VOCs, including naphthalene, 1,2-dichloroethane, o-xylene, 1,3-dichlorobenzene, tetrachloroethene, 1,2-dichlorobenzene, 1,2,4-trichlorobenzene, ethylbenzene, m-xylene, and p-xylene, were obtained by the ranking of the detected VOCs according to their occurrence and ecological effects. These compounds should be given more attention in monitoring and drainage control strategies. 相似文献
19.
Characterizations of volatile organic compounds during high ozone episodes in Beijing,China 总被引:3,自引:0,他引:3
Air samples were collected in Beijing from June through August 2008, and concentrations of volatile organic compounds (VOCs)
in those samples are here discussed. This sampling was performed to increase understanding of the distributions of their compositions,
illustrate the overall characteristics of different classes of VOCs, assess the ages of air masses, and apportion sources
of VOCs using principal compound analysis/absolute principal component scores (PCA/APCS). During the sampling periods, the
relative abundance of the four classes of VOCs as determined by the concentration-based method was different from that determined
by the reactivity approach. Alkanes were found to be most abundant (44.3–50.1%) by the concentration-based method, but aromatic
compounds were most abundant (38.2–44.5%) by the reactivity approach. Aromatics and alkenes contributed most (73–84%) to the
ozone formation potential. Toluene was the most abundant compound (11.8–12.7%) during every sampling period. When the maximum
incremental reactivity approach was used, propene, toluene, m,p-xylene, 1-butene, and 1,2,4-trimethylbenzene were the five
most abundant compounds during two sampling periods. X/B, T/B, and E/B ratios in this study were lower than those found in
other cities, possibly due to the aging of the air mass at this site. Four components were extracted from application of PCA
to the data. It was found that the contribution of vehicle exhaust to total VOCs accounted for 53% of VOCs, while emissions
due to the solvent use contributed 33% of the total VOCs. Industrial sources contributed 3% and biogenic sources contributed
11%. The results showed that vehicle exhausts (i.e., unburned vehicle emissions + vehicle internal engine combustion) were
dominant in VOC emissions during the experimental period. The solvent use made the second most significant contribution to
ambient VOCs. 相似文献
20.
P. Ciccioli A. Cecinato E. Brancaleoni A. Brachetti M. Frattoni 《Environmental monitoring and assessment》1994,31(1-2):211-217
HRGC-MS determinations carried out on samples collected in urban, suburban, rural, forest and remote areas suggest that several other classes of non-methane VOC than isoprene and monoterpene hydrocarbons can be emitted by plants. Because of their high photochemical reactivity, they can contribute to tropospheric ozone production which, in turn, can cause climate changes through radiative forcing. 相似文献