首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
通过动态法测试水吸收型空气净化器A和活性炭过滤吸附型净化器B对甲醛的去除性能,探索更为合理的方法以评价空气净化器对气态污染物的去除性能.对净化器A去除甲醛的短期测试结果表明,净化器对甲醛浓度为0.3、0.5、0.8和1 mg/m3的连续空气流均有明显的净化效果,对甲醛的去除速率在0.91~2.78 mg/h之间.对净化...  相似文献   

2.
Lone Star Steel has developed a family of high performance, long life, low capital, and low operating cost Hydro-Sonic* cleaners. A choice of driving mediums is available; either a compressible fluid ejector or fan may be used. The ejector models have no moving parts in the gas stream. Where available, waste heat may be used to power the cleaners. Cleaning levels are adjustable by the user by the selective input of energy. The Coalescer model employs a unique pressure recovery device for separation thereby reducing energy requirements for the cleaner. The Hydro-Sonic cleaners are operational In the steel, paper, and other industries.  相似文献   

3.
This paper describes the analysis of hazardous waste oil samples with procedures that were developed primarily to clean up and analyze biological samples. Details of the cleanup procedure and the results from the analysis of several waste PCB oil samples are presented.  相似文献   

4.
Decision-makers require useful tools, such as indicators, to help them make environmentally sound decisions leading to effective management of hazardous wastes. Four hazardous waste indicators are being tested for such a purpose by several countries within the Sustainable Development Indicator Programme of the United Nations Commission for Sustainable Development. However, these indicators only address the 'down-stream' end-of-pipe industrial situation. More creative thinking is clearly needed to develop a wider range of indicators that not only reflects all aspects of industrial production that generates hazardous waste but considers socio-economic implications of the waste as well. Sets of useful and innovative indicators are proposed that could be applied to the emerging paradigm shift away from conventional end-of-pipe management actions and towards preventive strategies that are being increasingly adopted by industry often in association with local and national governments. A methodological and conceptual framework for the development of a core-set of hazardous waste indicators has been developed. Some of the indicator sets outlined quantify preventive waste management strategies (including indicators for cleaner production, hazardous waste reduction/minimization and life cycle analysis), whilst other sets address proactive strategies (including changes in production and consumption patterns, eco-efficiency, eco-intensity and resource productivity). Indicators for quantifying transport of hazardous wastes are also described. It was concluded that a number of the indicators proposed could now be usefully implemented as management tools using existing industrial and economic data. As cleaner production technologies and waste minimization approaches are more widely deployed, and industry integrates environmental concerns at all levels of decision-making, it is expected that the necessary data for construction of the remaining indicators will soon become available.  相似文献   

5.
Abstract

A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-μm particles ranged from 1.5 hr?1 during operation of an in-duct, 5-in. pleated media filter to 7.2 hr?1 for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr?1 when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 μm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr?1 under baseline conditions, 0.5 hr?1 during operation of three portable ionic air cleaners, 1 hr?1 for an in-duct 1-in. media filter, 2.4 hr?1 for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr?1 for an in-duct 5-in. media filter, 4.7 hr?1 during operation of five portable HEPA filters, 6.1 hr?1 for a conventional in-duct electronic air cleaner, and 7.5 hr?1 for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.  相似文献   

6.
Metallic, masonry, and other solid debris that may be contaminated with hazardous chemicals litter numerous hazardous waste sites in the United States. Polychlorinated biphenyls (PCBs), pesticides, lead or other metals are some of the contaminants of concern. In some cases, cleanup standards have been established (e.g., 10 μg PCBs/100 cm2 for surfaces to which humans may be frequently exposed). Decontaminated debris could be either returned to the site as “clean” fill or, in the case of metallic debris, sold to a metal smelter.

This project involves the development and demonstration of a technology specifically for per forming on-site decontamination of debris. Both bench-scale and pilot-scale versions of a debris washing system (DWS) have been designed, constructed, and demonstrated. The DWS entails the application of an aqueous solution during a high-pressure spray cycle, followed by turbulent wash and rinse cycles. The aqueous cleaning solution is recovered and reconditioned for reuse concurrently with the debris-cleaning process, which minimizes the quantity of process water required to clean the debris.  相似文献   

7.
The issue of fine particle (PM2.5) exposures and their potential health effects is a focus of scientific research because of the recently promulgated National Ambient Air Quality Standard for PM2.5. Before final implementation, the health and exposure basis for the standard will be reviewed by the U.S. Environmental Protection Agency within the next five years. As part of this process, it is necessary to understand total particle exposure issues and to determine the relative importance of the origin of PM2.5 exposure in various micro-environments. The results presented in this study examine emissions of fine particles from a previously uncharacterized indoor source: the residential vacuum cleaner. Eleven standard vacuum cleaners were tested for the emission rate of fine particles by their individual motors and for their efficiency in collecting laboratory-generated fine particles. An aerosol generator was used to introduce fine potassium chloride (KCl) particles into the vacuum cleaner inlet for the collection efficiency tests. Measurements of the motor emissions, which include carbon, and the KCl aerosol were made using a continuous HIAC/Royco 5130 A light-scattering particle detector. All tests were conducted in a metal chamber specifically designed to completely contain the vacuum cleaner and operate it in a stationary position. For the tested vacuum cleaners, fine particle motor emissions ranged from 9.6 x 10(4) to 3.34 x 10(8) particles/min, which were estimated to be 0.028 to 176 micrograms/min for mass emissions, respectively. The vast majority of particles released were in the range of 0.3-0.5 micron in diameter. The lowest particle emission rate was obtained for a vacuum cleaner that had a high efficiency (HEPA) filter placed after the vacuum cleaner bag and the motor within a sealed exhaust system. This vacuum cleaner removed the KCl particles that escaped the vacuum cleaner bag and the particles emitted by the motor. Results obtained for the KCl collection efficiency tests show > 99% of the fine particles were captured by the two vacuum cleaners that used a HEPA filter. A series of tests conducted on two vacuum cleaners found that the motors also emitted ultra-fine particles above 0.01 micron in diameter at rates of greater than 10(8) ultra-fine particles/CF of air. The model that had the best collection efficiency for fine particles also reduced the ultra-fine particle emissions by a factor of 1 x 10(3).  相似文献   

8.
The performance of gaseous air cleaners for commercial and residential buildings has typically been evaluated using test protocols developed for a controlled laboratory chamber or a test duct. It is currently unknown how laboratory measurements relate to the actual performance of an air cleaner installed in a real building. However, to date, there are no air cleaner field test protocols available, thereby limiting the existing field data. The National Institute of Standards and Technology (NIST) has conducted a series of experiments to support test procedure development for evaluating the installed performance of gaseous air cleaning equipment, as well as metrics for characterizing field performance. To date, over 100 experiments have been completed, of which 23 portable air cleaner experiments and 6 in-duct air cleaner experiments are described in this paper. Tests were conducted in a finished three-bedroom/two-bathroom manufactured house equipped with several gas chromatographs to semi-continuously measure air change rates and volatile organic compound concentrations. Experimental variables included air cleaner location, isolation of zones by closing doors, and contaminant source location. For each experiment, air cleaner removal of decane was directly measured using the air cleaner inlet and outlet concentrations, as well as with mass balance analyses using measured room concentrations. With a verified mass balance model, a field performance metric was developed to compare installed whole-building performance to the performance predicted by a laboratory result. The results provide insight into the protocols and metrics that might prove useful for characterizing the field performance of air cleaners as well as the impact of air cleaner removal on zonal concentration levels in a variety of situations.  相似文献   

9.
ABSTRACT

The issue of fine particle (PM25) exposures and their potential health effects is a focus of scientific research because of the recently promulgated National Ambient Air Quality Standard for PM2 5. Before final implementation, the health and exposure basis for the standard will be reviewed by the U.S. Environmental Protection Agency within the next five years. As part of this process, it is necessary to understand total particle exposure issues and to determine the relative importance of the origin of PM2 5 exposure in various micro-environments. The results presented in this study examine emissions of fine particles from a previously uncharacterized indoor source: the residential vacuum cleaner. Eleven standard vacuum cleaners were tested for the emission rate of fine particles by their individual motors and for their efficiency in collecting laboratory-generated fine particles. An aerosol generator was used to introduce fine potassium chloride (KC1) particles into the vacuum cleaner inlet for the collection efficiency tests. Measurements of the motor emissions, which include carbon, and the KCl aerosol were made using a continuous HIAC/Royco 5130A light-scattering particle detector. All tests were conducted in a metal chamber specifically designed to completely contain the vacuum cleaner and operate it in a stationary position. For the tested vacuum cleaners, fine particle motor emissions ranged from 9.6 x 104 to 3.34 x 108 particles/min, which were estimated to be 0.028 to 176 mg/min for mass emissions, respectively. The vast majority of particles released were in the range of 0.3-0.5 mm in diameter. The lowest particle emission rate was obtained for a vacuum cleaner that had a high efficiency (HEPA) filter placed after the vacuum cleaner bag and the motor within a sealed exhaust system. This vacuum cleaner removed the KC1particles that escaped the vacuum cleaner bag and the particles emitted by the motor. Results obtained for the KC1 collection efficiency tests show >99% of the fine particles were captured by the two vacuum cleaners that used a HEPA filter. A series of tests conducted on two vacuum cleaners found that the motors also emitted ultra-fine particles above 0.01 mm in diameter at rates of greater than 108 ultra-fine particles/CF of air. The model that had the best collection efficiency for fine particles also reduced the ultra-fine particle emissions by a factor of 1 x 103.  相似文献   

10.
In the Hazardous and Solid Waste Amendments of1984, Congress declared the objective of the national waste policy to be "to promote the protection of health and the environment and to conserve valuable material and energy resources." Further, Congress stated that this would be done by minimizing the generation and land disposal of hazardous waste by encouraging process substitutions, materials recovery, proper recycling and reuse, and treatment.

This paper presents the approach used by 3M to find innovative ways to minimize the amount of hazardous waste which ultimately must be disposed by landfilling. The life cycle of waste is examined, looking at how it can be reduced or eliminated starting with the point of generation in the manufacturing operation, to its processing, treatment or ultimate disposal as a residual hazardous waste. Case histories are used as examples of how waste can be minimized in each stage of the life cycle, with emphasis on innovative alternatives that have arisen out of the 3Mprogram.  相似文献   

11.
掌握填埋废物的工程力学特性是确保危险废物填埋堆体稳定性的重要前提条件,因此,针对6种典型危险废物的工程力学特性开展了调查研究.研究结果表明,污泥类危险废物的含水率和有机质含量远高于非污泥类危险废物,而前者的比重则显著低于后者.污泥类危险废物的渗透系数相对较小,比污染土壤和飞灰炉渣混合物的渗透系数小1个数量级,比滤池填料的渗透系数小2个数量级.不同危险废物的无侧限抗压强度排序为:飞灰炉渣混合物(314.3 kPa)和滤池填料(278.9 kPa)>污染土壤(124.9 kPa)>杭州氧气厂污泥(68.6 kPa)、锌铬污泥(71.4 kPa)、油泥(58.4 kPa).不同危险废物的粘聚力排序为:飞灰炉渣混合物(40.8 kPa)、滤池填料(31.1 kPa)>污染土壤(20.9 kPa)>杭州氧气厂污泥(1.94kPa)、锌铬污泥(3.10 kPa)、油泥(1.81 kPa).此外,不同危险废物的内摩擦角差异相对较小,其变化范围在18.8°~35.0°之间.综合分析可知,飞灰炉渣混合物和滤池填料的工程力学特性较好,而污泥类危险废物的工程力学特性则较差.  相似文献   

12.
This paper discusses the Chemical Manufacturers Association's 1984 survey of the chemical industry's hazardous waste management practices. The survey data include a breakdown of how the industry's hazardous wastes are managed, detailing generation, treatment and disposal, and cover 725 plants in 81 companies. The 1984 survey is the third CM A hazardous waste survey, and the paper discusses resultant waste treatment trends from 1981- 1984, the period covered by previous surveys. A total of 278.5 million tons of hazardous waste was treated and disposed by survey respondents. Of this, 276.8 million tons was hazardous wastewater and 1.7 million tons was solid hazardous waste. The survey solid hazardous waste total was projected to the entire industry (Standard Industrial Code 2800) and is estimated at 6.9 million tons. The survey showed continued decreasing trends in hazardous waste generation in the chemical industry. It demonstrated changes in hazardous waste management practices, with decreased use of landfills and increased incineration of the solid wastes that are generated.  相似文献   

13.
无锡市作为江苏重点发展的城市,随着社会和经济的快速发展,危险废物产生量和种类不断增多。文中针对无锡市2011年—2018年危险废物产生量、综合利用与处置情况,分析危险废物处置利用存在的问题,同时,就目前危险废物存在的问题,提出科学合理的建议。  相似文献   

14.
Iron oxide-loaded slag for arsenic removal from aqueous system   总被引:5,自引:0,他引:5  
Zhang FS  Itoh H 《Chemosphere》2005,60(3):319-325
An effective adsorbent for arsenic removal from aqueous system was synthesized by loading iron(III) oxide on municipal solid waste incinerator melted slag. The loading was accomplished via chemical processes and thermal coating technique. The key point of the technique was the simultaneous generation of amorphous FeOOH sol and silica sol in-situ and eventually led to the formation of Fe-Si surface complexes which combined the iron oxide with the melted slag tightly. The surface morphology of the iron oxide-loaded slag was examined and the loading mechanisms were discussed in detail. The adsorbent was effective for both arsenate and arsenite removal and its removal capabilities for As(V) and As(III) were 2.5 and 3 times of those of FeOOH, respectively. Both affinity adsorption and chemical reactions contributed to arsenic removal. The effects of solution pH, contact time, arsenic concentration and adsorbent dosage on arsenic removal were examined and the optimum removal conditions were established. Furthermore, leaching of hazardous elements such as Cr(VI), As, Se, Cd and Pb from the adsorbent at a pH range of 2.5-12.5 was below the regulation values. Accordingly, it is believed that the iron oxide-loaded slag developed in this study is environmentally acceptable and industrially applicable for wastewater treatment.  相似文献   

15.
采用零排放新工艺处理蚀刻废液   总被引:1,自引:0,他引:1  
广州市某化工厂开发出一套对线路板蚀刻废液进行大规模集中资源化处理的零排放处理新工艺,该工艺通过在固相条件下生成氧化铜并用重力分选的方法将其分离出来,克服了原有工艺的缺陷,使废液中所有的成分能够在较低的处理成本下全部分离回收,无三废排出,达到了清洁生产的要求.对其工艺条件进行深入研究,通过正交试验优化了工艺条件.  相似文献   

16.
Goal, Scope and Background Reducing occupant exposure to indoor mold is the goal of this research, through the efficacy testing of antimicrobial cleaners. Often mold contaminated building materials are not properly removed, but instead surface cleaners are applied in an attempt to alleviate the problem. The efficacy of antimicrobial cleaners to remove, eliminate or control mold growth on surfaces can easily be tested on non-porous surfaces. However, the testing of antimicrobial cleaner efficacy on porous surfaces, such as those found in the indoor environment such as gypsum board can be more complicated and prone to incorrect conclusions regarding residual organisms. The mold Stachybotrys chartarum has been found to be associated with idiopathic pulmonary hemorrhage in infants and has been studied for toxin production and its occurrence in water damaged buildings. Growth of S. chartarum on building materials such as gypsum wallboard has been frequently documented. Methods Research to control S. chartarum growth using 13 separate antimicrobial cleaners on contaminated gypsum wallboard has been performed in laboratory testing. Popular brands of cleaning products were tested by following directions printed on the product packaging. Results A variety of gypsum wallboard surfaces were used to test these cleaning products at high relative humidity. The results indicate differences in antimicrobial efficacy for the six month period of testing. Discussion Results for the six types of GWB surfaces varied extensively. However, three cleaning products exhibited significantly better results than others. Lysol All-Purpose Cleaner-Orange Breeze (full strength) demonstrated results which ranked among the best in five of the six surfaces tested. Both Borax and Orange Glo Multipurpose Degreaser demonstrated results which ranked among the best in four of the six surfaces tested. Conclusions The best antimicrobial cleaner to choose is often dependent on the type of surface to be cleaned of S. chartarum contamination. For Plain GWB, no paint, the best cleaners were Borax, Lysol All-Purpose Cleaner-Orange Breeze (full strength), Orange Glo Multipurpose Degreaser, and Fantastik Orange Action. Recommendations and Perspectives These results are not meant to endorse the incomplete removal of mold contaminated building materials. However, it is recognized that complete removal may not always be possible and solutions to control mold regrowth may contribute to reduced occupant exposure. Current recommendations of removal and replacement of porous building materials should be followed. It is not the intension of this discussion to endorse any product. Reporting on the performance of these products under the stated conditions was and remains the only purpose. ESS-Submission Editor: Dr. Lee Young (youngrisk@bresnan.net)  相似文献   

17.
The foundry industry is a major consumer of waste materials (scrap). Unfortunately, the recycling of these waste materials can result in the generation of hazardous wastes that must be properly managed at a significant cost. This article focuses on two waste streams in the foundry industry; calcium carbide desulfurization slag and melt emission control residuals. The author presents an overview of how foundries have evaluated different waste management options with the ultimate goal of minimizing the generation of hazardous waste.  相似文献   

18.
A research study was performed to determine the fats, oil, and grease (FOG) removal efficiency of internal flow-based grease interceptors (FGI). A passive-flow and a mechanical-flow FGI unit were tested and their performance was compared to an external retention-based grease interceptor (RGI). Experiments involved multiple parameters including three oil/water emulsion strengths, two influent liquid temperatures, and two flow rates. Overall, the RGI achieved approximately 80% FOG removal and the FGIs removed less than 50% under the tested conditions. One exception occurred during the passive FGI testing during which removal reached approximately 80%. This increased efficiency was likely due to the relatively weak emulsion exhibiting significantly large FOG globules. The FOG removal efficiency decreased with increased temperature because of increased breakage of FOG globules at the elevated temperature. These results suggest that emulsion strength significantly affects FOG removal efficiency of FGIs and should be considered in future manufacturer testing protocol.  相似文献   

19.
Biopower can diversify energy supply and improve energy resiliency. Increases in biopower production from sustainable biomass can provide many economic and environmental benefits. For example, increasing biogas production through anaerobic digestion of food waste would increase the use of renewable fuels throughout California and add to its renewables portfolio. Although a biopower project will produce renewable energy, the process of producing bioenergy should harmonize with the goal of protecting public health. Meeting air emission requirements is paramount to the successful implementation of any biopower project. A case study was conducted by collecting field data from a wastewater treatment plant that employs anaerobic codigestion of fats, oils, and grease (FOG), food waste, and wastewater sludge, and also uses an internal combustion (IC) engine to generate biopower using the biogas. This research project generated scientific information on (a) quality and quantity of biogas from anaerobic codigestion of food waste and municipal wastewater sludge, (b) levels of contaminants in raw biogas that may affect beneficial uses of the biogas, (c) removal of the contaminants by the biogas conditioning systems, (d) emissions of NOx, SO2, CO, CO2, and methane, and (e) types and levels of air toxics present in the exhausts of the IC engine fueled by the biogas. The information is valuable to those who consider similar operations (i.e., co-digestion of food waste with municipal wastewater sludge and power generation using the produced biogas) and to support rulemaking decisions with regards to air quality issues for such applications.

Implications: Full-scale operation of anaerobic codigestion of food waste with municipal sludge is viable, but it is still new. There is a lack of readily available scientific information on the quality of raw biogas, as well as on potential emissions from power generation using this biogas. This research developed scientific information with regard to quality and quantity of biogas from anaerobic co-digestion of food waste and municipal wastewater sludge, as well as impacts on air quality from biopower generation using this biogas. The need and performance of conditioning/pretreatment systems for biopower generation were also assessed.  相似文献   


20.
Bioremediation, the process by which hazardous substances are degraded by microorganisms, is at the forefront of a larger group of innovative remediation technologies being applied at hazardous waste sites worldwide. Although the process of bioremediation has been utilized for decades in the field of wastewater engineering, its application to soils and groundwater at hazardous waste sites is fairly new and still undergoing intensive development. This article is intended to provide both an overview of the state of practice of bioremediation in hazardous waste remediation operations, and an inventory of issues to consider when evaluating the use of this technology for a contaminated site. These topics will be the subject matter of a unique Bioremediation Satellite seminar to be broadcast on January 9, 1992. The seminar, a joint venture between the Air and Waste Management Association (A&WMA) and the Hazardous Waste Action Coalition (HWAC), is the first in a series of satellite seminars that will deal with innovative hazardous waste remediation technologies. The intent of these seminars is to design programs which will make hazardous waste practitioners more familiar with innovative remediation technologies so that they will consider using the technologies in future clean-up operations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号