首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Health care staff who operate magnetic resonance imaging (MRI) devices are exposed to a static magnetic field of significant spatial heterogenity always produced by MRI magnets during the whole shift. They can also be exposed to pulses of a time-varying magnetic field (gradient field) present only during patients' examinations. The level of the workers' exposure depends both on the type of the magnet and on the ergonomic design of each MRI device. The paper presents methods used for measuring and assessing workers' exposure. It also discusses the results of inspection measurements carried out next to approximately 20 MRI devices of approximately 0.2-2.0 T. The presented characteristic and overview of the variability of workers' exposure to a variety of MRI devices supports the need for data on monitoring occupational exposure to MRI. International exposure assessment standards and guidelines (International Commission on Non-Ionizing Radiation Protection [ICNIRP], Institute of Electrical and Electronics Engineers [IEEE], American Conference of Governmental and Industrial Hygienists [ACGIH], European Commission directive), and those established in Poland are also compared.  相似文献   

2.
This review describes the general provisions of and the philosophy behind European Directive 2004/40/EC and ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines. As an example of national legislation on the protection of workers against excessive electromagnetic field exposure, regulations established in Poland are summarized. The problems of a practical implementation of the Directive’s provisions are discussed.  相似文献   

3.
This review describes the general provisions of and the philosophy behind European Directive 2004/40/EC and ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines. As an example of national legislation on the protection of workers against excessive electromagnetic field exposure, regulations established in Poland are summarized. The problems of a practical implementation of the Directive's provisions are discussed.  相似文献   

4.
The aim was to investigate occupational exposure to electric and magnetic fields during tasks at ground or floor level at 110?kV substations in Finland and to compare the measured values to Directive 2013/35/EU. Altogether, 347 electric field measurements and 100 magnetic field measurements were performed. The average value of all electric fields was 2.3?kV/m (maximum 6.4?kV/m) and that of magnetic fields was 5.8?µT (maximum 51.0?µT). It can be concluded that the electric and magnetic field exposure at ground or floor level is typically below the low action levels of Directive 2013/35/EU. The transposition of the directive will not create new needs to modify the work practice of the evaluated tasks, which can continue to be performed as before. However, for workers with medical implants, the exposure may be high enough to cause interference.  相似文献   

5.
The spectrum and the polarization of the magnetic flux density (B-field) of 6 induction heaters and 1 arc oven were measured by means of a PMM (Italy) spectrum analyser. The spectrum analysis showed that no substantial harmonics were observed while the polarization analysis revealed that the operator's exposure was non-homogeneous within a distance of 1.5 m from the heater. When the distance was larger, the body was homogeneously exposed. In general we can state that the B-field strongly varied between heaters and that exposure exceeded the occupational reference levels recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) (1998) and European Directive 2004/40/EC in 5 of the 7 heaters. Within the framework of the Directive some protection actions should be taken. Whereas mitigation of existing/old induction ovens is difficult, the design of new induction heaters and their housing should be based, among others, on electromagnetic reducing engineering concepts.  相似文献   

6.
The thermal environment in the workplace is an important factor which affects workers’ health. During 2011 in Poland, 14,781 workers were exposed to a cold working environment, i.e., 3.8% of persons employed in hazardous work conditions. The aim of this study was to determine the cardiovascular response to continuous (4 °C for 60 min) and intermittent (10 min at 4 °C and 10 min at room temperature alternately) exposure to the cold in 30 healthy men aged 20–27 years. Peripheral blood flow was assessed with impedance plethysmography. Heart rate and arterial blood pressure were monitored with the Holter system. Having assessed the results, it is difficult to say which kind of exposure has a more severe impact on the cardiovascular system. Longer observation and a more detailed analysis would be necessary (e.g., Doppler echocardiography).  相似文献   

7.
The aim of this study is to investigate the levels of electric and magnetic power frequency fields at 8 electrical transformation stations in the North-East counties of Romania and to check their compliance with standards. Spot measurements were carried out on both electric and magnetic fields under overhead conductors of 110-, 220- and 380-kV installations. The magnetic field levels were several orders of magnitude below the reference level for occupational exposure set by ICNIRP (International Commission on Non-Ionizing Radiation) or by Romanian regulations. In contrast, the electric field levels were about the same order of magnitude as the reference levels. In 2 electrical stations the reference level of 10 kV/m was exceeded at specific locations within the outdoor installations area. However, the additional reference level for short-time exposure included in Romanian regulations, 30 kV/m, was not exceeded.  相似文献   

8.
Introduction. This study measures the exposure of occupational therapists from a 1.5-T magnetic resonance imaging (MRI) machine. Method. A total of 14 time-series on each of the chest, head and hand were taken before and after different MRI procedures. The peak values were noted in each case together with an average of all data recorded in the time-series. Results. The highest exposure recorded was observed on the hand, followed by the head and the chest. The overall maximum exposure (1479.40?mT) recorded was observed on the hand during a change of coil. It was also observed that the recorded exposure of experienced radiographers working in the MRI environment was less than that of junior staff due to different practices. Conclusion. This study is of significant importance in Malta since it is the first conducted in a MRI environment, especially because the results were compared with limits imposed by EU Directive 2013/35/EU which has to be implemented by July 2016.  相似文献   

9.
分析了MOSFET(Metal-Oxide-Semiconductor Field-Effect Transistor)管固态电源高频焊机在工作过程中产生电磁场的机理,通过定性分析和实际测量描述了不同工作条件下的高频时变电场特征,与ICNIRP发布的限定值比较,分析了焊接作业人员的高频电磁曝露问题。通过对高频焊接环境电磁辐射的定量描述和认识,对于规范焊接操作,尽可能降低从业人员电磁曝露的影响具有指导意义。  相似文献   

10.
Whole-body vibration (WBV) exposure is a health hazard among workers, causing lower back pain (LBP) in the construction industry. This study examines key factors affecting LBP due to WBV exposure using exploratory factor analysis and structural equation modelling. The results confirm five key factors (equipment, job related, organizational, personal, social context) with their 17 associated items. The organizational factor is found the most important, as it influences the other four factors. The results also show that appropriate seat type, specific training programme, job rotation, workers’ satisfaction and workers’ physical condition are crucial in reducing LBP due to WBV exposure. Moreover, provision of new machines without proper training and good working condition might not help reduce LBP due to WBV exposure. The results help the construction companies to better understand key factors affecting LBP due to WBV exposure, and to plan for a better health improvement programme.  相似文献   

11.
We analyzed occupational exposure to potentially infectious body fluids among health care workers (HCWs). Nurses were the most common exposed category of HCWs. In 73.6% cases needle sticks had been the reason of exposure. Recapping a needle was the cause of exposure in 6.9% accidents. Among 189 registered HCWs, 66 (34.9%) performed invasive procedures without any personal protective equipment. Prophylaxis with antiretroviral drugs was necessary in 43 (22.8%) cases.

As many as 60.3% of exposure incidents to potentially infectious material result from non-compliance with the relevant recommendations. Continuous education and training is critically needed to prevent occupational exposure to blood-borne infections among health care workers.  相似文献   

12.
为了给污水处理厂微生物气溶胶的健康风险评价提供定量依据,于2011年6—7月利用Andersen 6级撞击式空气微生物采样仪对西安市第三污水处理厂氧化沟单元内不同距离处的细菌气溶胶进行现场采样,利用平皿培养和菌落计数对细菌进行分析。选用适于我国国情的暴露因子参数,建立暴露风险评价模型,对污水处理厂的工人及周围居民的健康风险进行评价。评价点的细菌气溶胶浓度采用修正的高斯模型计算。结果表明,呼吸吸入是人体(儿童和成人)摄入微生物气溶胶的主要途径,暴露非致癌风险商随距离的增加而逐渐降低。同种途径在同样位置,儿童的风险商是成年男性或成年女性的2~3倍。经呼吸途径的风险商从大到小为儿童、成年男性、成年女性,经皮肤接触途径的风险商从大到小为儿童、成年女性、成年男性。  相似文献   

13.
The newly released findings by the International Commission on Radiation Protection (ICRP) led to a review of the lifetime risk coefficients for fatal cancer used in J-value analysis of nuclear safety systems. The change in life expectancy a safety system brings about by averting a radiation exposure needs to be estimated in order to calculate the safety system's J-value, and this is done following the ICRP's practice of using risk coefficients that are uniform across both genders and all ages in the defined population group (either workers or the general population). The ICRP predicted uniformly lower radiation risks in 2007 than in 1990 on a like-for-like basis, but it was found that the ICRP's new risk coefficients needed to be multiplied by a compensating factor specific to each population when used in calculating the radiation-induced change in life expectancy. Incorporating the new compensating factor leads to a decrease in the J-value calculated of about 5% for workers and 15% for the general population compared with earlier, reported results. These adjustments are not large compared with the uncertainties associated with radiation harm and the economics of installing a safety system, but will strengthen slightly the case for spending on a nuclear safety measure.  相似文献   

14.
纳米技术产业的快速发展促使纳米材料需求量不断增长,纳米材料的规模化生产及使用,增加了暴露于超细颗粒物的职业人群数量,且工种复杂多样,尤其在自动化程度低、工人职业卫生防护意识薄弱的作业场所,对接触者有潜在的职业暴露风险.从现场暴露评估策略、检测方法、接触限值以及风险评估手段,综述针对超细颗粒物这一新型职业危害因素的研究进...  相似文献   

15.
Terence Price 《Safety Science》2010,48(10):1498-1515
PurposeThe purpose of this research is to assess whether the practice of retro-fitting passive magnetic shielding to Magnetic Resonance Imaging (MRI) suites is effective in retaining the 0.5 mT footprint of the static magnetic field to within its designed position.MethodologyThe research methodology involved identification of an MRI installation where passive magnetic shielding was to be fitted to an installation already in operational use. Site based physical measurements of the magnetic flux density of the static field were then taken both ante and post installation of the shielding, so as to be able to determine its effectiveness.FindingsThe results identified areas in the retrofitted magnetic shielding where, as a result of its design, hot spots in excess of 0.5 mT occurred.Practical implicationsThis research highlights design, construction and safety issues that the designer could, if he had this prior knowledge, have eliminated at source.ValueAt the planning stage of a new MRI suite, designers could use the information contained in this research as part of their design risk management process. This research serves to demonstrate the importance of eliminating any possible future need to install retrofitted passive magnetic shielding to an original MRI suite design. It also shows the need for designers to identify the location of any hot spots in the shielding installation where the magnetic flux density may exceed 0.5 mT and become a potential hazard to those individuals fitted with heart pacemakers or other electronic body implants.  相似文献   

16.
电子工业脉冲噪声对工人健康影响的调查研究   总被引:1,自引:0,他引:1  
对电子行业接触脉冲噪声的冲压工进行了调查,其脉冲噪声水平波动在102~112dB(八)之间(峰值),对作业工人听力已产生不同程度的损伤,心电图在中高工龄组有改变。还分析了脉冲噪声引起听力损失与暴露时间有密切关系。提出了进一步加强安全监督管理的对策。  相似文献   

17.
Air pollutants emitted while processing phenol-formaldehyde resins have been investigated. Gas chromatography-mass-selective detection was used to separate and identify chemical compounds. It was determined that workers were exposed to formaldehyde in all workplaces. Besides, phenol, acetaldehyde, acrylaldehyde, 2-furaldehyde, xylene, ethylbenzene, toluene, tetrachlorethene, ethyl acetate, butyl acetate were found during the production of frictional materials; and 2-furaldehyde, phenol, naphthalene, 2-furan-methanol, polycyclic aromatic hydrocarbons (PAHs) during the production of abrasive materials. Quantitative analyses were performed with gas chromatogra-phy and high performance liquid chromatography. Assessment of occupational exposure indicated that chemical compounds emitted during the investigated processes might be dangerous for human health, mainly because of suspected carcinogenic compounds: formaldehyde and PAHs.  相似文献   

18.
The basis of the manSievert as a unit for collective radiation dose is discussed and previous recommendations are considered for how much should be spent to avert a collective dose of 1 manSv. New calculations are given using the J-value method. It is shown that the value to be assigned to averting a manSievert depends on the duration of averted exposure as well as on the net discount rate and the loan rate thought to be appropriate. Different figures will result depending on whether the exposed group consists of workers or the general public. The variation with dose duration is so large that it is not possible to recommend a single figure for the value of a manSievert. Instead, tables are given at two conservative, loan and net discount rates for the value of a manSievert as a function of exposure time. The base data for the J-value method need to be updated annually, and this means that the values given in the tables will increase over time as people live longer and become richer.  相似文献   

19.
The significance of engineered nanomaterials (ENM) and nanotechnologies grows rapidly. Nanotechnology applications may have a positive marked impact on many aspects of on human every day life, for example by providing means for the production of clean energy and pure drinking water. Hundreds of consumer nano-based products are already on the market. However, very little is known of the risks of ENM to occupational safety and health (OSH), even though workers are likely to be at extra risk, as compared with other potentially exposed groups of people, because the levels of exposure are usually higher at workplaces than in other environments. However, knowledge of the exposure to, or effects of, ENM on human health and safety in occupational environments is limited and does not allow reliable assessment of risks of ENM on workers’ health. Several issues related to ENM in the workplaces require marked attention. The most topical issues include: (1) improved understanding of ENM metrics associated with ENM toxicity; (2) development of monitoring devices for ENM exposure assessment; (3) understanding the changes of ENM structure and state of agglomeration at different concentrations in aerosols; (4) understanding translocation of ENM in the human body; (5) identifying the key health effects of ENM including pulmonary toxicity, genotoxicity, carcinogenic effects, and effects on circulation; (6) development of tiered approaches for testing of safety of ENM; and (7) utilizing these data for health risk assessment, with a special emphasis on occupational environment. Available data on several ENM – ability to enter the body and reach almost any organ, to cause pulmonary inflammation and fibrosis, and even to cause increased risk of mesotheliomas in animal models, call for immediate action. It is crucial to identify those ENM that may cause occupational health and safety risks from those ENM which are innocent, hence allowing prioritization of regulatory and preventive actions at workplaces at national, regional and global levels.  相似文献   

20.
Identification and determination of polycyclic aromatic hydrocarbons (PAHs) in Diesel exhaust in the working environment and assessment of workers’ occupational exposure to these suspected human carcinogens were the aim of this experimental investigation.

The range of exposure factors calculated on the basis of 9 individual PAH concentrations determined in personal air samples shows that time-averaged concentration of these compounds did not exceed the Polish Maximum Admissible Concentration (MAC) value for PAHs, that is, 2 μg·m–3. The highest concentrations of PAHs were determined in the breathing zone of forklift operators. The maximum exposure factor was 0.427 μg·m–3 (about 1/4 of MAC).  相似文献   