首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
Hand cranks are used in a variety of industries to actuate valves and in other gear-operated applications. In order to evaluate these types of operations and their compatibility with operator strength capabilities, a rotational dynamometer was used to measure torque production capability of operators using a hand crank at different heights and angles (with respect to the coronal plane). The tests were conducted for both clockwise and counterclockwise rotations using the dominant arm of each test participant. A total of 18 tests were completed by each of five male right-handed test participants. A 0° declination angle, counterclockwise operation, and both 40.65 cm and 60.96 cm heights were found to be associated with the greatest torque production capabilities.  相似文献   

2.
通过开展小尺寸实验以及FDS数值模拟实验,研究纵向通风对不同高度竖井的排烟影响并确定最佳通风风速。通过分析纵向通风风速、竖井高度对吸穿现象、边界层分离的影响规律,讨论了吸穿现象的临界条件。小尺寸实验中纵向通风风速考虑了0.096 m/s、0.226 m/s、0.356 m/s、0.485 m/s、0.629 m/s五种工况,竖井高度考虑了0.133 m、0.2 m、0.333 m、0.533 m四种工况。实验结果表明:当纵向通风风速为0.096 m/s、0.226 m/s、0.356 m/s(对应实际风速0.37 m/s、0.87 m/s、1.38 m/s)时,可抑制吸穿现象,但烟气边界层分离现象随着风速的增加而加剧。吸穿现象临界判据F_(critical)=1.5在本文所测试的纵向通风条件下不再适用,但Ri′_(critical)=1.5依然适用。数值模拟结果表明:当竖井高度为1 m、1.5 m、2 m时,排烟量随纵向通风的增加而降低,而当其为3 m、4 m、5 m时,排烟量先上升后降低,在测试风速为1.5 m/s时达到最高值。  相似文献   

3.
Stairways are, in general, a thoroughly studied subject, but there is almost no scientific data available about spiral stairs. They are, however, widely used in homes, industrial sites and public buildings. The purpose of this study was to determine preferred handrail heights for a spiral stairway. The most preferred handrail height for descent was 105 cm. On the other hand, 95% of the participants regarded handrail heights between 95 and 100 cm satisfactory for descending. Participants’ anthropometric data was combined with the handrail height preference to develop a draft of a model to predict preferred handrail height for other user populations.  相似文献   

4.
为对高处作业人员位置状态进行识别,加强对高处施工人员作业状态的监控,采用VR技术模拟高处作业,同时利用人-机-环同步平台,采集平地处、一级高处作业(取4 m为例)以及二级高处作业(8 m为例)情景下的6种生理信号数据,运用SPSS软件对生理信号进行数据分析.结果显示,不同高处作业人员对皮电信号(EDA)的时域具有显著性...  相似文献   

5.
梁璇文  张俊  宋卫国  叶锐 《火灾科学》2020,29(3):181-189
为了研究利用虚拟现实开展行人疏散实验的有效性以及虚拟场景里不同控制方式的优劣,开展了真实世界与三种不同控制方式(头显-鼠标(HM)、鼠标-鼠标(MM)、键盘-鼠标(KM))下虚拟场景的绕障实验。分析并比较了平均轨迹、绕障距离、绕障起始时间以及归一化时间下的横向距离。实验结果表明,当横向坐标小于1 m时,虚拟场景与真实世界实验平均轨迹的差值在10 cm之内。平均轨迹、绕障距离、绕障起始时间方面,HM更接近真实世界实验;归一化时间下的横向距离方面,MM更接近真实世界实验。  相似文献   

6.
扣件弹条动力特性现场测试与研究   总被引:5,自引:0,他引:5  
为揭示扣件弹条在运行过程折断的原因,通过现场测试,得到弹条在客车和货车以不同速度运行下的工作模态,并进行仿真分析,以验证识别结果的正确性。结果表明:不同行车条件下,弹条振动的优势频率是固定不变的。采用省时Ibraham时域法(STD)、复指数法和自回归滑动平均模型(ARMA)分析法对弹条的加速度进行识别,均可以较为准确地得到弹条的工作模态;边界条件不一样,如道钉螺栓扭矩不同,左右侧弹条的工作模态是不一致的;弹条的前两阶固有频率是容易被激起共振的频率,在弹条设计应重点考虑避免之,在现场弹条安装和运行维护时,对道钉螺栓的扭矩要特别注意。  相似文献   

7.
以活性污泥等生物基质为填料.在不同的水力负荷和有机负荷条件下,研究了地下渗滤系统对生活污水的处理效果.中试结果表明:地下渗滤系统对COD、NH_4~+-N和TP有着良好的去除效果,在水力负荷为4 cm·d~(-1),污染负荷为280 mg·L~(-1)和320 mg·L~(-1)时.COD、NH_4~+-N和TP的去除去分别达到91.2%、97.2%、88.0%和90.6%、95.6%、90.4%;水力负荷达到450 mg·L~(-1)时,有机物及氨氮的去除率下降迅速,仅为83.2%和85.5%,TP的去除率略有提高,为91.7%;平均污染负荷为300 mg·L~(-1),水力负荷为4.0 cm·d~(-1)、6.5 cm·d~(-1)和8.1 cm·d~(-1)时,COD、NH+4_4~+-N和TP的去除率分别达到90.6%、97.4%、90.0%.87.3%、96.8%、84.0%和85.6%,96.3%,83.3%;适宜的生活污水处理条件是水力负荷为8.1 cm·d~(-1),污染负荷低于450 mg·L~(-1).在以上工况下的出水水质均优于生活杂用水水质标准(CJ251-89)和沈阳市污水处理中水回用标准,处理效果稳定;系统垂直方向的氨化细菌分布较均匀,硝化细菌在70 cm以上区域数量较多,反硝化细菌在70 cm以下区域数量较多;氨化细菌与COD、NH_4~+-N和TN的去除率的相关性显著,硝化及反硝化细菌与COD、NH_4~+-N和TN的去除率的相关性极显著;氨化、硝化和反硝化细菌与TP的去除率的相关性均不显著,说明生物作用不是TP脱除的主要途径.  相似文献   

8.
为研究不同工况、不同结构参数对于深水水下测试树球阀剪切连续油管性能的影响,采用有限元分析软件建立剪切分析模型,对不同工况下剪切过程进行数值模拟,并与试验对比验证分析模型的准确性;结果显示,有限元模型结果与试验结果相对偏差小于5%;油管剪切过程中会出现2个剪切力矩峰值,通过分析不同工况下2个峰值变化规律,发现油管承受拉力越大、球阀剪切速度越小、球阀外径越小剪切过程所需剪切力越小,剪切性能越好。研究结果表明:得到的剪切模型及不同工况下剪切力变化规律,可为水下测试树的设计选型及现场应用提供指导及参考意义。  相似文献   

9.
石凯  姚斌  江梦梦  舒雅 《火灾科学》2012,21(2):98-103
光纤光栅感温火灾报警系统在石油化工行业储罐区等易燃易爆场所得到应用,但目前尚没有相关的国家级设计规范,且安徽省和湖北省地方设计规范关于感温探测器敷设间距的要求存在较大差异,有必要开展深入研究。以外浮顶原油罐为例进行研究,获得了差温和定温两种探测方式在两种敷设高度下,其敷设间距与罐径之间的关系表达式,二者呈正相关。研究结果表明,初起阶段火源功率与罐径呈线性关系且火源功率较小,按照地方规范设置敷设间距时,难以对其进行及时探测,应加大敷设密度;差温探测比定温探测方式具有更为快速探测报警优势且可以设置较大的敷设间距。  相似文献   

10.
为提高闸阀可靠度计算准确性,将模糊准则引入闸阀可靠性设计,将闸阀应力与阀体通径、内压之间隐式关系显式化,并基于神经网络构建地震工况下闸阀数学模型;利用蒙特卡洛法,计算闸阀在常规方法下的可靠度;利用正态型隶属函数描述闸阀强度的模糊性,计算闸阀在考虑模糊强度时的可靠度;对比强度的模糊性对可靠度计算结果的影响,分析不同隶属函数下的闸阀模糊可靠度。与传统随机可靠度计算方法相比,该方法对不确定性描述更合理,理论上对可靠度的计算更加准确。  相似文献   

11.
The aim of this work is to determine the influence of operating parameters such as the dispersion pressure, the ignition delay and height on the dust flammability. A Computational Fluid Dynamics (CFD) simulation, based on an Euler–Lagrange approach, was developed with Ansys Fluent™ and validated experimentally. Such analysis will facilitate the choice of the most conservative conditions for a flammability test. This paper is focused on a case study performed on wheat starch with the modified Hartmann tube. The dispersion process of the powder was studied with granulometric analyses performed in situ and high speed videos. Tests were performed with injections at gas pressure ranging from 3 to 6 bars and the evolution of the particle size distribution (PSD) was recorded at different ignition heights (5, 10 and 15 cm over the dispersion nozzle). The observations highlighted the presence of agglomeration/deagglomeration processes and dust segregation. Besides, a CFD simulation analysis was aimed at evaluating the impact of a set of parameters on the PSD and the local turbulence, which are closely linked to some flammability parameters. For this computational analysis, the CFD simulation was coupled with a collision treatment based on a Discrete Element Method (DEM) in order to consider the cohesive behavior of the combustible dust. Thus the results suggest performing the injection of the gases at approximately 5 bars for the flammability tests of wheat starch in order to obtain the finest PSD at a given ignition height. It is also shown that the finest PSD are obtained at 5 cm over the dispersion nozzle. However, the local instabilities and turbulence levels are so high during the first stages of the dispersion that the flame growth can be disturbed for short ignition delays. Moreover, the stabilization of the bulk of the dust cloud requires longer periods of time when the ignition sources are located at 15 cm. As a result, the recommended height to perform a flammability test is 10 cm in this case. Finally, this study proposes some tools that might improve the procedure of dust flammability testing.  相似文献   

12.
为提高污水地下渗滤系统(Subsurface Waste-water Infiltration System,SWIS)的生物脱氮效率,改进了基质床体结构组成,采用土柱模拟试验对比了基质床改进前后ORP特征及氨化、硝化及反硝化细菌数量的变化。结果表明,在地下渗滤系统中,氨氮的去除率(Q)随基质层深度的变化规律为Q(100 cm)Q(80 cm)Q(20 cm)≈Q(40 cm)Q(60 cm)。改进后基质铺设顺序依次为:0~60 cm填充炉渣和草甸棕壤(两者体积比为3∶7),60~130 cm铺设活性污泥、炉渣和草甸棕壤(三者体积比为1∶2∶7)。基质床结构组成改进后,20~60 cm区域氧化电位(ORP)大幅提高,尤其60 cm深度处ORP从0提高到180 m V,有效促进了硝化反应的进行;床体氨化、硝化及反硝化细菌数量大幅度提高,对NH+4-N及TN的脱除效率分别较改进前提高了12.6%和10.5%,出水NH+4-N及TN质量浓度满足城市景观地表水水质标准(GB/T 18921—2002)。  相似文献   

13.
This paper presents a numerical study involving the deformation of contact faces in the metal-to-metal seal in a typical pressure relief valve. The valve geometry is simplified to an axisymmetric problem, which comprises a simple geometry consisting of only 3 components. A cylindrical nozzle, which has a valve seat on top, contacts with a disk, which is preloaded by a compressed linear spring. All the components are made of AISI type 316N(L) steel defined using the multilinear kinematic hardening model based on monotonic and cyclic tests at 20° C. In-service observations show that there is a limited fluid leakage through the valve seat at operational pressures about 90% of the set pressure, which is caused by the fluid penetrating into surface asperities at the microscale. Nonlinear FEA in ANSYS using the fluid pressure penetration (FPP) technique revealed that there is a limited amount of fluid penetrating into gap, which is caused by the plastic deformation of the valve seat at the macroscale. Prediction of the fluid pressure distribution over the valve seat just before the valve lift is addressed in this study considering the FPP interaction on multiscale. This is the principal scope, since it allows adjustment of the valve spring force in order to improve the leak tightness.  相似文献   

14.
This study was to investigate the effects of grip force, frequency, stroke rotation and grip-span on discomfort and obtain best posture for hand tool users. Fifteen male participants volunteered in this study. Participants performed combined gripping with torqueing exertions for 5 min for two levels of frequency (10 and 20 exertions/min) at two levels of grip force (50 and 70 N), two levels of stroke rotation (30 and 60) and three levels of grip-span (4.7, 6 and 7.3 cm). Therefore, a 2×2×2×3 full factorial design was used. The analysis of variance (ANOVA) showed that frequency, stroke rotation and grip-span were significant on discomfort score. Minimum discomfort and comfortable posture was found to be 90 N grip force with 10 exertions/min for 60° stroke rotation at 6-cm grip-span. The grip force, frequency and stroke rotation were found significant on EMG activity of forearm muscles using multivariate analysis of variance (MANOVA). The extensor muscles were found more activated than flexor muscles during the given task.  相似文献   

15.
An electronically-controlled sampling system, characterised by its organ pipe design, has been developed for sampling air sequentially, at different heights within the breathing zone. Data are automatically logged at the different receptor levels, for the determination of the average vertical concentration profile of gaseous pollutants. The system has been coupled to a carbon dioxide monitor and used in a brief study of the spatial and temporal variation of indoor carbon dioxide concentration. The system can easily be extended for different heights or modified for use with other types of gas monitor. The results of a trial run, which was carried out in a coffee room, are presented and applications of the Organ Pipe Sequential Sampling (OPSS) system are discussed.  相似文献   

16.
Back problems resulting from the compression forces on the intervertebral disks during manual material-handling tasks are an important problem affecting workers in various industries. The quantification of these forces using intradiscal pressure or biomechanical modeling is complex, time consuming, and costly, and these methods cannot be readily used in the workplace to estimate loadings on the lower back. The objective of this study was to develop a predictive model that would allow the estimation of lumbar loadings for lifting and lowering boxes using easily measured anthropometric variables and variables related to the task. A dynamic and planar segmental model and a model of internal forces at L5/S1 were used to determine the compression forces on the lower back. Two predictive models, a field model and a laboratory model, were developed to estimate the compression forces when lifting or lowering 3.3 kg to 22.0 kg boxes between heights of 15 cm and 185 cm. Both models were validated by an examination of the residuals. Their predictive performance was also compared, with the laboratory model offering a slightly better prediction than the field model. Thus, these equations represent a practical tool for a better planning of handling tasks in the working environment with the purpose of reducing the back injuries of workers.  相似文献   

17.
提出漏风量换气次数的概念,并以此作为评价气流控制阀是否适用于生物安全实验室压差控制的指标;提出引入附加漏风量的气密性生物安全实验室压差控制策略。进行对比实验,研究实验室在无人为漏风量与引入人为漏风量这两种情况下启动、微扰动、关门等工况下实验室的压差波动情况,其结果显示在引入人为漏风量情况下实验间压差波动范围减小、稳定速度加快。从而说明引入附加漏风量的压差控制策略在气密性生物安全实验室的压差控制方面具有重要的实际应用价值。  相似文献   

18.
Subjective annoyance response to diesel engine sound during idling conditions was evaluated by 80 participants. Eight different sound spectra were presented to the participants at a constant level of 80 dB(A) in a paired comparison procedure. Stereo-recorded sound stimuli were played back through a pair of loudspeakers in an anechoic room. Four objective parameters of loudness, sharpness, impulsiveness, and roughness were found to be the determining factors that cause subjective annoyance. An annoyance prediction model for the test stimuli of an idling diesel engine was developed on the basis of these factors. The objective parameters and their interactions have a significant effect on the annoyance prediction model. The spectral distribution indicated by test participants to be pleasant can be used as a basis for appropriate modification of engine sound. A single microphone measurement in free field conditions can be used to estimate objective parameters for defining the cause of annoyance.  相似文献   

19.
《组织行为杂志》2017,38(7):923-949
Empirical evidence suggests that power elicits a generic tendency to disregard advice. We examined different responses power holders may show in their tendency to take advice depending on the construal of power. We report a field study and an experiment among managers and other powerful professionals (Studies 1 and 2) and an experiment in which participants were assigned to a powerful role (Study 3). Across studies, we found a higher tendency to take advice among those who construed their power as a responsibility rather than as an opportunity. This effect of the construal of power on advice taking was mediated by a heightened perceived value of advice, not by decreased confidence in own judgments or sense of power. Accordingly, the increase in advice taking when power was construed as a responsibility was observed regardless of whether the advice came from subordinates (Study 1), expert advisors (Study 2), or a less powerful teammate (Study 3). This highlights the relevance of considering how power holders construe their power in order to understand their tendency to take advice from others. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

20.
A synthesis of previous literature is used to derive a model of an in-service direct-spring pressure relief valve. The model couples low-order rigid body mechanics for the valve to one-dimensional gas dynamics within the pipe. Detailed laboratory experiments are also presented for three different commercially available values, for varying mass flow rates and length of inlet pipe. In each case, violent oscillation is found to occur beyond a critical pipe length, which may be triggered either on valve opening or closing. The test results compare favorably to the simulations using the model. In particular, the model reveals that the mechanism of instability is a Hopf bifurcation (flutter instability) involving the fundamental, quarter-wave pipe mode. Furthermore, the concept of the effective area of the valve as a function of valve lift is shown to be useful in explaining sudden jumps observed in the test data. It is argued that these instabilities are not alleviated by the 3% inlet line loss criterion that has recently been proposed as an industry standard.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号