首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
IC反应器处理高浓度硫酸盐废水的启动研究   总被引:3,自引:0,他引:3  
采用木糖生产废水,进行了(IC)反应器处理高浓度硫酸盐有机废水的启动研究.结果表明,接种厌氧颗粒污泥,当进水COD/SO2-4值约为3.5时,控制COD负荷提高幅度为每次20%左右,经过26 d的驯化培养,COD和SO2-4负荷分别可达20 kg/(m3·d)和5.5 kg/(m3·d),COD去除率达到80%以上,硫...  相似文献   

2.
The presence of a high concentration of sodium in wastewater is considered inhibitory for anaerobic biological treatment. This research was designed to investigate the potential use of halophilic methanogens and a mixed culture of halophilic methanogens and digester sludge, in anaerobic filters, for treatment of organic pollutants in high-saline wastewater at 35 degrees C. Data related to startup of the filters are presented. Both halophilic and mixed-culture anaerobic filters were able to operate at a sodium chloride concentration of 35 g/L, at organic loading rates (OLRs) of 6.2 and 5 kg chemical oxygen demand (COD)/m(3) x d, respectively. The COD removal efficiency was as high as 80%, and the systems were able to maintain a low volatile fatty acids concentration of 500 mg/L. No significant difference in COD removal was observed between the halophilic filter and the mixed-culture filter. Increasing the salt concentration to 37 g/L at an OLR of 3 kg/m(3) x d caused system failure.  相似文献   

3.
开发了一种处理农村污水的低能耗地埋式一体化溅水充氧生物滤池装置,通过拔风和溅水复合充氧技术实现了大幅度节能条件下的好氧生物处理.考察了在不同水力负荷及COD、NH4 -N容积负荷条件下本装置的处理效果,结果表明,在水力负荷小于10 m3/(m2·d)、COD及NH4 -N容积负荷分别小于0.3 kg COD/(m3·d)和0.08 kg NH4 -N/(m3·d)的条件下,可以取得较高的去除效果和良好的出水水质,COD、NH4 -N和TN的平均出水浓度分别为58.94 mg/L、2.78 mg/L和8.23 mg/L,平均去除率分别为51.7%、86.4%和70.6%.  相似文献   

4.
外循环式UASB反应器处理高浓度酒精废水   总被引:1,自引:1,他引:0  
利用改进型上流式厌氧污泥床反应器在中温条件下处理高浓度酒精废水,研究反应器的启动影响因素及颗粒污泥形成过程,分析反应器运行特性。在容积负荷为10.39 kg COD/(m3.d),COD去除率达90.2%,VFA在300 mg/L以下,平均产气率为0.328 m3/kg COD,取得最佳的运行效果,为高浓度酒精废水的处理应用提供科学依据。  相似文献   

5.
采用耐酸驯化的厌氧消化污泥处理餐厨垃圾,在酸性条件下(pH=4.5),对实验装置容积负荷从1.0 kg VS/(m3·d)分9次逐级增加到5.0 kg VS/(m3·d)的过程进行了跟踪监测,并较深入地研究了驯化污泥代谢活性和处理效果。实验结果表明,pH 4.5的耐酸厌氧消化污泥,最佳投加负荷约为4.5 kg VS/(m3·d),此负荷下容积产气率,CH4含量平均值均达最大,分别为1.68 m3/(m3·d),75.0%。耐酸厌氧消化装置持续增料运行46 d,产甲烷菌仍能保持较高的活性,其COD去除率范围为40.4%~75.0%,仍能保持pH 7.2时处理效果的65.0%~91.8%,表明在低pH、低碱度下实现稳定的产甲烷过程是可行的。  相似文献   

6.
多级厌氧法处理螺旋霉素工业发酵菌渣效果的研究   总被引:2,自引:0,他引:2  
通过自主设计的多级厌氧反应器系统来考察半连续处理螺旋霉素工业发酵菌渣的效果。该系统总反应体积为44 L,由4个11 L的升流式厌氧反应罐组成,罐体间采用串联方式连接。121 d的连续运行周期分为3个阶段,各阶段的有机负荷率分别为1.27、1.82和2.73 kg COD/(m3·d)。全过程中主要监测了各级罐体的产气量和螺旋霉素的降解。结果表明,多级厌氧反应器系统启动初期会出现产气不稳定现象,经过2个月的运行之后系统达到稳定状态。在有机负荷达到2.73 kg COD/(m3·d)时,各级罐体仍能稳定运行,总产气的45%集中在1号罐。在系统启动初期,螺旋霉素不能被明显降解。运行约80 d后,整个体系达到了快速降解螺旋霉素的状态,在2.73 kg COD/(m3·d)的有机负荷率下,螺旋霉素降解率达到97%,同时可溶性COD降解率也达到了90%。  相似文献   

7.
Attempts were made in this study to examine the effectiveness of sequencing batch reactor (SBR) for the treatment of beverage industrial wastewater. The SBR was operated at three different organic loading rates (OLRs): 2, 1.7 and 1.1 kg COD/m3 d. Results of continuous long-term operation showed that by decreasing OLR from 2 to 1.7 kg COD/m3 day, the removal efficiency was increased from 95.5 to 99.3% for COD, from 95.3 to 98.1% for BOD and from 87 to 97.7% for TSS. While further decreasing of the OLR to 1.1 kg COD/m3 day, there is no significant adverse effect on organics removal. Also, residual total nitrogen (TN) concentration decreased by decreasing the OLR. However, increasing the OLRs exerted a slightly negative effect on the removal of total phosphorous. On the other hand, the experimental data indicated that the substrate utilization kinetic followed Monod's kinetics model approximately. The maximum specific substrate utilization rate (micro(max), half velocity coefficient (Ks), growth yield coefficient (Y) and decay coefficient (Kd) were 2.94 d(-1), 15.22 mg/L, 0.2384 g VSS/g COD and 0.2019 h(-1), respectively.  相似文献   

8.
The effects of the organic loading rate (OLR) on the performance and the granular sludge characteristics of an expanded granular sludge bed (EGSB) reactor used for treating real traditional Chinese medicine (TCM) wastewater were investigated. Over 90 % of the COD removal by the EGSB reactor was observed at the OLRs of 4 to 13 kg COD/(m3 day). However, increasing the OLR to 20 kg COD/(m3 day) by reducing the hydraulic retention time (HRT 6 h) reduced the COD removal efficiency to 78 %. The volatile fatty acid (VFA) concentration was 512.22 mg/L, resulting in an accumulation of VFAs, and propionic acid was the main acidification product, accounting for 66.51 % of the total VFAs. When the OLR increased from 10 to 20 kg COD/(m3 day), the average size of the granule sludge decreased from 469 to 258 μm. There was an obvious reduction in the concentration of Ca2+ and Mg2+ in the granular sludge. The visible humic acid-like peak was identified in the three-dimensional excitation-emission matrix (EEM) fluorescence spectra of the soluble microbial products (SMPs). The fatty acid bond, amide II bond, amide III bond, and C–H bond bending were also observed in the Fourier transform infrared (FTIR) spectra of the SMPs. Methanobacterium formicicum, Methanococcus, and Bacteria populations exhibited significant shifts, and these changes were accompanied by an increase in VFA production. The results indicated that a short HRT and high OLR in the EGSB reactor caused the accumulation of polysaccharides, protein, and VFAs, thereby inhibiting the activity of methanogenic bacteria and causing granular sludge corruption.  相似文献   

9.
UASB处理硫酸盐有机废水的启动   总被引:1,自引:0,他引:1  
为了考察上流式厌氧污泥床反应器(UASB)处理含硫酸盐有机废水的特性,采用有效容积为10 L的UASB,研究了启动运行过程中COD和SO2-4降解情况、出水VFA和pH值、产气量及颗粒污泥比产甲烷活性(SMA)变化状况。结果表明,接种厌氧颗粒污泥,保持进水COD为1 500 mg/L,SO2-4浓度为100 mg/L,将HRT由24 h缩短至12 h以提高负荷,经历55 d成功启动了UASB反应器;当HRT为12 h,进水COD和SO2-4负荷为3.0 kg/(m3·d)和0.20 kg/(m3·d),COD和SO2-4的去除率分别达到80%和89%,出水VFA为3 mmol/L,产气量达9.5 L/d,颗粒污泥的SMA为86.4 mL/(g VSS·d)。  相似文献   

10.
内循环厌氧反应器的启动及影响因素   总被引:1,自引:0,他引:1  
采用内循环(IC)厌氧反应器,以生产淀粉和酒精的混合废水为处理对象,研究了中温条件下IC反应器的启动及影响因素。结果表明:接种厌氧消化污泥进行培养,逐渐提高进水有机负荷,运行105 d后,可实现IC反应器的启动;当进水COD浓度为11 500 mg/L,有机容积负荷为6.13 kg COD/(m3·d),COD去除率能到达95%左右;水力停留时间对启动过程没有影响,而温度和温度波动影响COD去除率;VFA比pH更能准确快速地反眏出反应器内部环境的变化,防止反应器的酸化;反应器内污泥实现颗粒化,并且具有良好的沉降性。  相似文献   

11.
以城市污水为处理对象,以絮状污泥为接种污泥,在连续流气提式好氧颗粒污泥流化床(CAFB)反应器中成功培养得到好氧颗粒污泥.探讨了CAFB中颗粒污泥的形成过程、生物多样性、有机物的去除行为及氮转化特性.研究结果表明,CAFB运行第7天颗粒污泥占主要优势,系统中依次出现原、后生动物,表明颗粒污泥趋于成熟.CAFB反应器中培养的好氧颗粒污泥具有良好的COD及NH4+-N去除能力.稳定运行阶段,当进水的COD容积负荷在1.5 ~3.5 kg COD/(m3·d)的范围时,COD的去除负荷稳定在1.0~2.0 kg COD/(m3·d).控制水力停留时间为(4 ±0.25)h、溶解氧质量浓度为(5 ±0.5) mg/L,可达到最高的硝化效率,但此控制条件下反硝化作用不明显.分析认为,作为完全混合式反应器的CAFB,需要较严格的控制溶解氧才能实现同步硝化反硝化作用.  相似文献   

12.
向成功启动并稳定运行630 d后的UASB生物膜反应器系统连续添加有机物,分析其对厌氧氨氧化反应脱氮效果的影响,并进行氮素浓度负荷试验.在厌氧氨氧化反应器系统中连续投加有机COD(葡萄糖),系统运行稳定,有机COD(葡萄糖)存在对系统去除氮素能力影响不大,有机COD去除率达到92.0%,仅用23 d,在同一反应器系统中成功实现了厌氧氨氧化与反硝化协同作用脱氮.氮素浓度负荷试验阶段,进水氨氮(NH 4-N)、亚硝氮(NO-2-N)以及总氮(TN)浓度负荷分别从0.063 kg/(m3·d)和0.063 kg/(m3·d)和0.126 kg/(m3·d)提升到了0.239 kg/(m3·d)、0.315 kg/(m3·d)和0.554 kg/(m3·d),相应去除率分别为84.0%、93.0%和85.0%,厌氧氨氧化工艺的UASB生物膜反应器对氮素浓度负荷仍有很大提升空间.  相似文献   

13.

Performance and microbial community composition were evaluated in a two-phase anaerobic and aerobic system treating sulfate-rich cellulosic ethanol wastewater (CEW). The system was operated at five different chemical oxygen demand (COD)/SO4 2− ratios (63.8, 26.3, 17.8, 13.7, and 10.7). Stable performance was obtained for total COD removal efficiency (94.5%), sulfate removal (89.3%), and methane production rate (11.5 L/day) at an organic loading rate of 32.4 kg COD/(m3·day). The acidogenic reactor made a positive contribution to net VFAs production (2318.1 mg/L) and sulfate removal (60.9%). Acidogenic bacteria (Megasphaera, Parabacteroides, unclassified Ruminococcaceae spp., and Prevotella) and sulfate-reducing bacteria (Butyrivibrio, Megasphaera) were rich in the acidogenic reactor. In the methanogenic reactor, high diversity of microorganisms corresponded with a COD removal contribution of 83.2%. Moreover, methanogens (Methanosaeta) were predominant, suggesting that these organisms played an important role in the acetotrophic methanogenesis pathway. The dominant aerobic bacteria (Truepera) appeared to have been responsible for the COD removal of the SBR. These results indicate that dividing the sulfate reduction process could effectively minimize sulfide toxicity, which is important for the successful operation of system treating sulfate-rich CEW.

  相似文献   

14.
IC厌氧反应器处理有机废水启动实验研究   总被引:1,自引:0,他引:1  
设计了一套IC反应器装置,接种啤酒厂生产废水消化污泥,采用人工配水对其进行启动运行,考察了IC反应器的启动运行状况、效果及影响因素,并在反应器运行结束后观察了污泥状态的变化.结果表明,容积负荷提高至4.7 kg/(m3·d),出水COD浓度稳定在250 mg/L左右,去除率维持在85%以上,反应器内出现污泥分层现象,颗...  相似文献   

15.
内循环(IC)厌氧反应器处理糖蜜酒精废水的研究   总被引:6,自引:2,他引:4  
糖蜜酒精废水由于含有高浓度的COD和硫酸盐,一般厌氧反应器无法有效处理.研究了IC反应器处理糖蜜酒精废水的效果.考察其COD及硫酸盐的去除率、沼气的产量和组分等.结果表明,反应器对于COD为5000~10 000 mg/L的中、高浓度废水去除效果良好,当COD在20 000~30 000 mg/L时,在适应了1~2个停留时间后,去除效果达到稳定,去除率在90%左右.实验中最高容积负荷提升至40 kg COD/m3·d左右.本研究中所用的糖蜜酒精废水的COD/SO24-的平均值为61.9,未对反应器的处理效果及产气量产生影响.  相似文献   

16.
采用中试规模复合生物滤池处理城市高污染水体,考察了滤池的最佳运行参数以及对氮和有机物的去除效果。结果表明:滤池容积负荷宜控制为0.3~0.5 kg COD/(m3.d),水力负荷4.5~5 m3/(m2.d),适宜的通风比为9%,当C/N为5~8时,滤池COD、NH4+-N和TN平均去除率分别为80%、83%和63%,达到高效同步硝化反硝化状态。  相似文献   

17.
Biostyr曝气生物滤池处理城市污水的沿程生化特性   总被引:1,自引:0,他引:1  
王琳  窦娜莎 《环境工程学报》2013,7(8):2942-2946
青岛市麦岛污水处理厂采用曝气生物滤池(BAF)处理城市污水,以稳定运行的Biostyr为研究载体,考察滤池COD、NH3-N、SS和细菌数量等生化特性的沿程变化.结果表明,在气水比为4∶1~5∶1、进水COD负荷为2.5 ~3.7 kg/(m3·d)、进水NH3-N负荷为0.18~0.57 kg/(m3·d)时,滤池对COD的降解主要在150 cm填料以下处,COD的去除率可达58.9%;NH3-N去除率沿滤柱高度的变化与COD有所不同,在100 cm以下填料处,NH3-N的去除率仅为3.6%,在100 ~350 cm填料之间,NH3-N的去除率增加迅速,可达56.1%;对SS的去除主要发生在100 cm填料以下,去除率达51.7%.  相似文献   

18.
采用内循环好氧生物流化床对中低浓度糖业废水进行生物降解,当进水COD、NH3-N浓度分别为400~600mg/L和7~11 mg/L时,其相应去除率达到80%~90%和70%~80%,处理效果良好;COD容积负荷可达到5.1 kg COD/(m3·d),反应器具有较强的抗负荷冲击能力.采用臭氧氧化工艺对COD浓度为28...  相似文献   

19.
在中试规模下,研究青岛市餐厨垃圾与菜市场垃圾混合(质量比1∶1)高温厌氧消化实验,通过监测厌氧消化过程中产气量、气体组成等产气情况和消化液中pH值、SCOD、NH3-H、VFAs含量和组分等化学指标变化,确定混合厌氧消化的最大有机负荷,并分析混合高温厌氧消化技术的可行性,结果表明,(1)青岛市餐厨垃圾与菜市场垃圾混合高温厌氧消化产甲烷具有技术可行性;(2)混合厌氧消化的最大有机负荷可达4.069 kg VS/(m3.d);(3)当系统最大有机负荷时,每天每千克VS最高可产生甲烷量0.346 m3;(4)混合厌氧消化可削减氨氮对餐厨垃圾单独厌氧消化产沼气的影响。  相似文献   

20.
为了探讨矿化垃圾再利用于印染废水处理的可行性,研究了矿化垃圾生化反应床处理模拟印染废水的工艺参数,进行了优势菌群的镜检和提取、培养,实验结果表明,适宜的工艺运行参数如下为水力停留时间12~24 h,水力负荷100~140 L/(m3·d),COD污染负荷240~360 g/(m3·d),布水周期为24 h条件下的进水历时为6 h;适宜的工艺运行参数条件下,矿化垃圾生化反应床对模拟印染废水的COD去除率97%以上,总磷去除率95%以上,氨氮的去除率在98%以上;处理模拟印染废水的矿化垃圾生化反应床内的微生物群落以球菌为主,该菌体对模拟印染废水具有良好的专性降解作用。研究结果将对矿化垃圾的再利用和印染废水的处理提供一定的技术参考。  相似文献   