首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
氮源对于气相生物滴滤床的净化效果有显著的影响。由于喷淋液体在生物滴滤床中分布不均匀 ,导致床层中局部氮源不充足 ,从而使滤床的去除效果降低。提高喷淋液中氮源的浓度 ,可以较大幅度提高净化效率。采用NH-4 N会导致滤床中硝化细菌的生长和累积 ,使得异养菌和硝化细菌在溶解氧、氮源和填料空间上形成竞争 ,并致使氮源分布不均匀 ,而采用NO3 N作为氮源可以改善这种状况  相似文献   

2.
Sewage sludge and yard waste compost were used as biofilter materials and tested with respect to their capacity for removing ammonia from air at different water contents. Ammonia removal was measured in biofilters containing compost wetted to different moisture contents ranging from air dry to field capacity (maximum water holding capacity). Filters were operated for 15 days and subsequently analyzed for NH3/NH4+, NO2-, and NO3-. The measured nitrogen species concentration profiles inside the filters were used to calculate ammonia removal rates. The results showed that ammonia removal is strongly dependent on the water content in the filter material. At gravimetric water contents below 0.25 g H2O g solids(-1) for the yard waste compost and 0.5 g H2O g solids(-1) ammonia removal rates were very low but increased rapidly above these values. The sewage sludge compost filters yielded more than twice the ammonia removal rate observed for yard waste compost likely because of a high initial concentration of nitrifying bacteria originating from the wastewater treatment process and a high airwater interphase surface area that facilitates effective ammonia dissolution and transport to the biofilm.  相似文献   

3.
臭氧/高锰酸盐预氧化对生物过滤净水效能的影响   总被引:1,自引:0,他引:1  
比较了臭氧(O3)和高锰酸盐复合药剂(PPC)对水源水预氧化的助凝效果及其对后续陶粒生物过滤净水效能的影响.结果表明,两种预氧化剂投加量均为2 mg/L时,PPC的助凝效果较为明显,浊度和溶解性有机碳(DOC)的去除率分别由未投加氧化剂时的85.7%和24.2%提高到88.3Z和35.2%;O3能够增加沉淀后水的可生化性,使特征紫外吸光度(SUVA)由0.97L/(m·mg)降至0.89 L/(m·mg).PPC预氧化有助于生物过滤对浊度的稳定去除,而O3预氧化则有助于生物过滤对DOC的去除.与O3预氧化相比,PPC预氧化有利于后续生物过滤运行初期对NH4 -N的去除,二者后续生物过滤在前3个月对NH4 -N的平均去除率分别为26.6%和73.1%,运行后期二者NH4 -N去除率接近.当进水NH4 -N大于2.0 mg/L时,DO是其去除的主要限制因素.  相似文献   

4.
The long-term stability of a biofilter loaded with waste gases containing NH3 concentrations larger than 100 ppmv was studied in a laboratory-scale compost reactor. At an empty bed residence time (tau) of 21 sec, elimination capacities of more than 300 g NH3/m3/day were obtained at elimination efficiencies up to 87%. Because of absorption and nitrification, almost 80% of the NH3-N eliminated from the waste gas could be recovered in the compost as NH4(+)-N or NO2-/NO3(-)-N. The high elimination capacities could be maintained as long as the NH4+/ NOX- concentration in the carrier material was less than 4 g NH4+/NOx(-)-N/kg wet compost. Above this critical value, osmotic effects inhibited the nitrifying activity, and the elimination capacity for NH3 decreased. To restore the biofilter performance, a carbon source (methanol) was added to reduce NH4+/NOx- accumulated in the compost. Results indicate that methylotrophic microorganisms did convert NH4+/NOx- into biomass, as long as the NO3- content in the compost was larger than 0.1 g NO3(-)-N/kg compost. Removal efficiencies of CH3OH of more than 90% were obtained at volumetric loads up to 11,000 g CH3OH/ m3/day. It is shown that addition of CH3OH is a suitable technique for regenerating the compost material from osmotic inhibition as a result of high NH3 loading. The biofilter was operated for 4 months with alternating load ing of NH3 and CH3OH.  相似文献   

5.
Bioprocesses, such as biofiltration, are commonly used to treat industrial effluents containing volatile organic compounds (VOCs) at low concentrations. Nevertheless, the use of biofiltration for indoor air pollution (IAP) treatment requires adjustments depending on specific indoor environments. Therefore, this study focuses on the convenience of a hybrid biological process for IAP treatment. A biofiltration reactor using a green waste compost was combined with an adsorption column filled with activated carbon (AC). This system treated a toluene-micropolluted effluent (concentration between 17 and 52 µg/m3), exhibiting concentration peaks close to 733 µg/m3 for a few hours per day. High removal efficiency was obtained despite changes in toluene inlet load (from 4.2 × 10?3 to 0.20 g/m3/hr), which proves the hybrid system’s effectiveness. In fact, during unexpected concentration changes, the efficiency of the biofilter is greatly decreased, but the adsorption column maintains the high efficiency of the entire process (removal efficiency [RE] close to 100%). Moreover, the adsorption column after biofiltration is able to deal with the problem of the emission of particles and/or microorganisms from the biofilter.
ImplicationsIndoor air pollution is nowadays recognized as a major environmental and health issue. This original study investigates the performance of a hybrid biological process combining a biofilter and an adsorption column for removal of indoor VOCs, specifically toluene.  相似文献   

6.
This project demonstrated the biofiltration of a trichloroethylene (TCE)-contaminated airstream generated by air stripping groundwater obtained from several wells located at the Anniston Army Depot, Anniston, AL. The effects of several critical process variables were investigated to evaluate technical and economic feasibility, define operating limits and preferred operating conditions, and develop design information for a full-scale biofilter system. Long-term operation of the demonstration biofilter system was conducted to evaluate the performance and reliability of the system under variable weather conditions. Propane was used as the primary substrate necessary to induce the production of a nonspecific oxygenase. Results indicated that the process scheme used to introduce propane into the biofiltration system had a significant impact on the observed TCE removal efficiency. TCE degradation rates were dependent on the inlet contaminant concentration as well as on the loading rate. No microbial inhibition was observed at inlet TCE concentrations as high as 87 parts per million on a volume basis.  相似文献   

7.
ABSTRACT

A lab-scale study was conducted to determine the rate and extent of decomposition of three biofilter media materials—compost, hog fuel, and a mixture of the two in 1:1 ratio—used in biofiltration applied to removal of reduced sulfur odorous compounds from pulp mill air emissions. The rate of carbon mineralization, as a measure of biofilter media degradation, was determined by monitoring respiratory CO2 evolution and measuring the changes in carbon and nitrogen fractions of the biofilter materials over a period of 127 days. Both ambient air and air containing reduced sulfur (RS) compounds were used, and the results were compared. After 127 days of incubation with ambient air, about 17% of the media carbon was evolved as CO2 from compost as compared to 6 and 12% from hog fuel and the mixture, respectively. The decomposition showed sequential breakdown of carbon moieties, and three distinct stages were observed for each of the biofilter media. First-order rate kinetics were used to describe the decomposition stages. Decomposition rates in the initial stages were at least twice those of the following stages. Carbon mineralization showed close dependence on the C/N ratio of the biofilter material. Media decomposition was enhanced in the presence of RS gases as a result of increased bioactivity by sulfur-oxidizing bacteria and other microorganisms, thus reducing the media half-life by more than 50%. At higher concentrations of RS gases, the CO2 evolution rates were proportionally lower than those at the low concentrations because of the limited acid buffering capacity of the biofilter materials.  相似文献   

8.
Removal of ammonia from contaminated air by trickle bed air biofilters   总被引:6,自引:0,他引:6  
A trickle bed air biofilter (TBAB) was evaluated for the oxidation of NH3 from an airstream. Six-millimeter Celite pellets (R-635) were used for the biological attachment medium. The efficiency of the biofilter in oxidizing NH3 was evaluated using NH3 loading rates as high as 48 mol NH3/m3 hr and empty-bed residence times (EBRTs) as low as 1 min. Excess biomass was controlled through periodic backwashing of the biofilter with water at a rate sufficient to fluidize the medium. The main goal was to demonstrate that high removal efficiencies could be sustained over long periods of operation. Ammonia oxidation efficiencies in excess of 99% were consistently achieved when the pH of the liquid nutrient feed was maintained at 8.5. Quick recovery of the biofilter after backwashing was observed after only 20 min. Evaluation of biofilter performance with depth revealed that NH3 did not persist in the gas phase beyond 0.3 m into the depth of the medium (26% of total medium depth).  相似文献   

9.
Gaseous NH3 removal was studied in laboratory-scale biofilters (14-L reactor volume) containing perlite inoculated with a nitrifying enrichment culture. These biofilters received 6 L/min of airflow with inlet NH3 concentrations of 20 or 50 ppm, and removed more than 99.99% of the NH3 for the period of operation (101, 102 days). Comparison between an active reactor and an autoclaved control indicated that NH3 removal resulted from nitrification directly, as well as from enhanced absorption resulting from acidity produced by nitrification. Spatial distribution studies (20 ppm only) after 8 days of operation showed that nearly 95% of the NH3 could be accounted for in the lower 25% of the biofilter matrix, proximate to the port of entry. Periodic analysis of the biofilter material (20 and 50 ppm) showed accumulation of the nitrification product NO3- early in the operation, but later both NO2- and NO3- accumulated. Additionally, the N-mass balance accountability dropped from near 100% early in the experiments to approximately 95 and 75% for the 20- and 50-ppm biofilters, respectively. A partial contributing factor to this drop in mass balance accountability was the production of NO and N2O, which were detected in the biofilter exhaust.  相似文献   

10.
Abstract

This project demonstrated the biofiltration of a trichloroethylene (TCE)-contaminated airstream generated by air stripping groundwater obtained from several wells located at the Anniston Army Depot, Anniston, AL. The effects of several critical process variables were investigated to evaluate technical and economic feasibility, define operating limits and preferred operating conditions, and develop design information for a full-scale biofilter system. Long-term operation of the demonstration biofilter system was conducted to evaluate the performance and reliability of the system under variable weather conditions. Propane was used as the primary substrate necessary to induce the production of a nonspecific oxygenase. Results indicated that the process scheme used to introduce propane into the biofiltration system had a significant impact on the observed TCE removal efficiency. TCE degradation rates were dependent on the inlet contaminant concentration as well as on the loading rate. No microbial inhibition was observed at inlet TCE concentrations as high as 87 parts per million on a volume basis.  相似文献   

11.
Kim JH  Rene ER  Park HS 《Chemosphere》2007,68(2):274-280
The performance of a lab scale biofilter packed with biomedia, encapsulated by sodium alginate and polyvinyl alcohol was used for treating ammonia (NH(3)) gas at different loading rates. The metabolic end products during NH(3) oxidation were NH(4)(+), NO(3)(-) and NO(2)(-). It is noteworthy to mention that the immobilized cell biofilter required no separate acclimatization period and showed high removal efficiencies during the start of continuous experiments. The removal efficiency was nearly 100% when ammonia loading was 4.5gm(-3)h(-1) and the maximum elimination capacity achieved in this study was 5.5gNH(3)m(-3)h(-1) at a loading rate of 7.5gm(-3)h(-1). Shock loading studies were carried out to ascertain the response of the immobilized cells to fluctuations in inlet concentration and flow rate. The inlet loading rates were varied between 0.05 and 6gNH(3)m(-3)h(-1) during this phase of operation. The biofilter responded effectively to these shock loading conditions and recovered rapidly within 4-8h. Pressure drop values were consistently less and insignificant. The results from this study indicated that this immobilized cell biofilter could be considered as a potential option to treat NH(3) under steady and transient state operation.  相似文献   

12.
Chung YC  Huang C  Tseng CP  Pan JR 《Chemosphere》2000,41(3):329-336
Gas mixture of H2S and NH3 in this study has been the focus in the research area concerning gases generated from the animal husbandry and the anaerobic wastewater lagoons used for their treatment. A specific microflora (mixture of Thiobacillus thioparus CH11 for H2S and Nitrosomonas europaea for NH3) was immobilized with Ca-alginate and packed inside a glass column to decompose H2S and NH3. The biofilter packed with co-immobilized cells was continuously supplied with H2S and NH3 gas mixtures of various ratios, and the removal efficiency, removal kinetics, and pressure drop in the biofilter was monitored. The results showed that the efficiency remained above 95% regardless of the ratios of H2S and NH3 used. The NH3 concentration has little effect on H2S removal efficiency, however, both high NH3 and H2S concentrations significantly suppress the NH3 removal. Through product analysis, we found that controlling the inlet ratio of the H2S/NH3 could prevent the biofilter from acidification, and, therefore, enhance the operational stability. Conclusions from bioaerosol analysis and pressure drop in the biofilter suggest that the immobilized cell technique creates less environmental impact and improves pure culture operational stability. The criteria for the biofilter operation to meet the current H2S and NH3 emission standards were also established. To reach Taiwan's current ambient air standards of H2S and NH3 (0.1 and 1 ppm, respectively), the maximum inlet concentrations should not exceed 58 ppm for H2S and 164 ppm for NH3, and the residence time be kept at 72 s.  相似文献   

13.
Efficient nutrient removal in decentralized wastewater treatment systems is a challenging task. To improve the removal of organic matter and nitrogen from wastewater, two types of bioreactors using membrane-aerated biofilm reactor (MABR) and microbial fuel cell (MFC) techniques were evaluated. During more than 250 days of continuous-flow reactor operation, both reactors showed consistently high chemical oxygen demand removal (>86%). At an influent ammonium-nitrogen (NH4(+)-N) concentration of 30 mg N/L, the average effluent NH4(+)-N concentrations were 6.2 and 0.5 mg N/L for the MABR and MFC reactor, respectively, while the effluent nitrate-nitrogen (NO3(-)-N) concentrations were 5.4 mg/ L in the MABR and 19.2 mg/L in the MFC-based reactor. The overall total inorganic nitrogen removal efficiencies were 64% and 36% for the MABR and MFC reactor, respectively. At the measured dissolved oxygen concentrations of 5.2 and 0.23 mg/L in the aerobic/anoxic zone of the MFC and MABR, respectively, a specific oxygen uptake rate of 0.1 g O2/g VSS-d, resulting from ammonia oxidation, was detected in the settled sludge of the MFC, while no nitrifying activity of the sludge from the MABR was detected. Molecular microbial analysis demonstrated a link between the bacterial community structure and nitrifying activity. The relatively high abundance of Nitrosomonas europaea was associated with its detectable nitrification activity in the settled sludge of the MFC. The results suggest that MABR and MFC techniques have the potential to improve organic and nitrogen removal in decentralized wastewater systems.  相似文献   

14.
Development and performance of an alternative biofilter system   总被引:3,自引:0,他引:3  
Step tracer tests were carried out on lab-scale biofilters to determine the residence time distributions (RTDs) of gases passing through two types of biofilters: a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow. Results were used to define the flow patterns in the reactors. "Non-ideal flow" indicates that the flow reactors did not behave like either type of ideal reactor: the perfectly stirred reactor [often called a "continuously stirred tank reactor" (CSTR)] or the plug-flow reactor. The horizontal biofilter with back-mixing was able to accommodate a shorter residence time without the usual requirement of greater biofilter surface area for increased biofiltration efficiency. Experimental results indicated that the first bed of the modified biofilter behaved like two CSTRs in series, while the second bed may be represented by two or three CSTRs in series. Because of the flow baffles used in the horizontal biofilter system, its performance was more similar to completely mixed systems, and hence, it could not be modeled as a plug-flow reactor. For the standard biofilter, the number of CSTRs was found to be between 2 and 9 depending on the airflow rate. In terms of NH3 removal efficiency and elimination capacity, the standard biofilter was not as good as the modified system; moreover, the second bed of the modified biofilter exhibited greater removal efficiency than the first bed. The elimination rate increased as biofilter load increased. An opposite trend was exhibited with respect to removal efficiency.  相似文献   

15.
Ground-level O3 formation is becoming a major concern in many cities due to recent tightening of O3 regulations. To control O3 formation, more efficient treatment processes for O3 precursors, such as NOx and volatile organic compounds (VOCs), are needed. One promising new technology for removing both NOx and VOCs from off-gas streams is biofiltration, a simple process whereby contaminated air is passed through a biologically active packed bed. In this study, a toluene-degrading fungal bioreactor was used to treat an aerobic gas stream contaminated with NO. The fungal bioreactor removed 93% of the inlet 250-ppmv NO at an empty bed contact time (EBCT) of 1 min when supplied with 90 g/m3/hr toluene. The presence of NH4+ concentrations greater than 0.4 mg NH3/g dry packing medium, however, resulted in poor NO removal. The bioreactor achieved a maximum toluene elimination capacity of 270 g/m3/hr and maintained greater than 95% toluene removal efficiencies over the 175-day study period.  相似文献   

16.
17.
Cai Z  Kim D  Sorial GA 《Chemosphere》2007,68(6):1090-1097
Two independent parallel trickling bed air biofilters (TBABs) ("A" and "B") with two different typical VOC mixtures were investigated. Toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) were the target VOCs in the mixtures. Biofilter "A" was fed equal molar ratio of the VOCs and biofilter "B" was fed a mixture based on EPA 2003 emission report. Backwashing and substrate starvation operation were conducted as biomass control. Biofilter "A" and "B" maintained 99% overall removal efficiency for influent concentration up to 500 and 300 ppmv under backwashing operating condition, respectively. The starvation study indicated that it can be an effective biomass control for influent concentrations up to 250 ppmv for biofilter "A" and 300 ppmv for "B". Re-acclimation of biofilter performance was delayed with increase of influent concentration for both biofilters. Starvation operation helped the biofilter to recover at low concentrations and delayed re-acclimation at high concentrations. Furthermore, re-acclamation for biofilter "B" was delayed due to its high toluene content as compared to biofilter "A". The pseudo first-order removal rate constant decreased with increase of volumetric loading rate for both biofilters. MEK and MIBK were completely removed in the upper 3/8 media depth. While biofilter depth utilization for the removal of styrene and toluene increased with increase of influent concentrations for both biofilters. However, toluene removal utilized more biofilter depth for biofilter "B" as compared to biofilter "A".  相似文献   

18.
A high H2S concentration inhibits nitrification when H2S and NH3 are simultaneously treated in a single biofilter. To improve NH3 removal from waste gases containing concentrated H2S, a two-stage biofilter was designed to solve the problem. In this study, the first biofilter, inoculated with Thiobacillus thioparus, was intended mainly to remove H2S and to reduce the effect of H2S concentration on nitrification in the second biofilter, and the second biofilter, inoculated with Nitrosomonas europaea, was to remove NH3. Extensive studies, which took into account the characteristics of gas removal, the engineering properties of the two biofilters, and biological parameters, were conducted in a 210-day operation. The results showed that an average 98% removal efficiency for H2S and a 100% removal efficiency for NH3 (empty bed retention time = 23-180 sec) were achieved after 70 days. The maximum degradation rate for NH3 was measured as 2.35 g N day(-1) kg of dry granular activated carbon(-1). Inhibition of nitrification was not found in the biofilter. This two-stage biofilter also exhibited good adaptability to shock loading and shutdown periods. Analysis of metabolic product and observation of the bacterial community revealed no obvious acidification or alkalinity phenomena. In addition, a lower moisture content (approximately 40%) for microbial survival and low pressure drop (average 24.39 mm H2O m(-1)) for system operation demonstrated that the two-stage biofilter was energy saving and economic. Thus, the two-stage biofilter is a feasible system to enhance NH3 removal in the concentrated coexistence of H2S.  相似文献   

19.
Biofilter, dynamic modeling software characterizing contaminant removal via biofiltration, was used in the preliminary design of a biofilter to treat odorous hydrogen sulfide (H2S). Steady-state model simulations were run to generate performance plots for various influent concentrations, loadings, residence times, media sizes, and temperatures. Although elimination capacity and removal efficiency frequently are used to characterize biofilter performance, effluent concentration can be used to characterize performance when treating to a target effluent concentration. Model simulations illustrate that, at a given temperature, a biofilter cannot reduce H2S emissions below a minimum value, no matter how large the biofilter or how long the residence time. However, a higher biofilter temperature results in lower effluent H2S concentrations. Because dynamic model simulations show that shock loading can significantly increase the effluent concentration above values predicted by the steady-state model simulations, it is recommended that, to consistently meet treatment objectives, dynamic feed conditions should be considered. This study illustrates that modeling can serve as a valuable tool in the design and performance optimization of biofilters.  相似文献   

20.
A bench-scale biofilter was evaluated for removing ammonia (NH3) from poultry house exhaust. The biofilter system was equipped with a compost filter to remove NH3 and calcium oxide (CaO) filter to remove carbon dioxide (CO2). Removal of NH3 and CO2 from poultry house exhaust could allow treated air with residual heat to be recirculated back into the poultry house to conserve energy during winter months. Apart from its use as a plant nutrient, NH3 removal from poultry house exhaust could lessen the adverse environmental impacts of NH3 emissions. Ammonia and CO2 were measured daily with gas detector tubes while temperatures in the poultry pen and compost filter were monitored to evaluate the thermal impact of the biofilter on treated air. During the first 37 days of the 54-day study, exhaust air from 33 birds housed in a pen was treated in the biofilter; for the final 17 days, NH3-laden exhaust, obtained by applying urea to the empty pen was treated in the biofilter. The biofilter system provided near-complete attenuation of a maximum short-term NH3 concentration of 73 ppm. During the last 17 days, with a mean influent NH3 concentration of 26 ppm, the biofilter provided 97% attenuation. The CaO filter was effective in attenuating CO2. Compared with a biofilter sized only for NH3 removal, an oversized biofilter would be required to provide supplemental heat to the treated air through exothermic biochemical reactions in the compost. The biofilter could conserve energy in poultry production and capture NH3 for use as plant nutrient. Based on this study, a house for 27,000 broilers would require a compost filter with a volume of approximately 34 m3.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号