首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

From simultaneous air and water polychlorinated biphenyl (PCB) measurements collected in September 2010, we re-evaluated the direction and magnitude of net air-water exchange of PCBs in southwest Lake Michigan and compared them with estimations made using similar approaches 15 years prior. Air and water samples were collected during a research expedition on Lake Michigan at 5 km off the coast of Chicago, with prevailing winds from the southwest of our location. Gas-phase ΣPCB concentrations ranged from 190 to 1100 pg m?3 with a median of 770 pg m?3, which is similar to the concentrations measured in the City of Chicago at the same time and similar to concentrations measured in this part of the lake over the last 20 years. Water dissolved-phase ΣPCB concentrations ranged from 150 to 170 pg L?1 with a median of 160 pg L?1, which is one-tenth of that measured in the 1990s. ?PCB net fluxes showed a slightly absorptive behavior, with a median of (?) 21 ng m?2 day?1 and an interquartile range of (?) 47 to (+) 5 ng m?2 day?1, where (?) and (+) fluxes indicate absorption and volatilization, respectively. Airborne PCB concentrations were higher when the winds were coming from Chicago and drive the deposition. Our fluxes are not significantly different from estimations from 1994 and 1995 and suggest that absorption of PCBs into the waters is slightly more prevalent than 15 years ago. It was confirmed that Chicago remains an important atmospheric source of PCBs to Lake Michigan.

  相似文献   

2.
Sediment cores from four Chilean lakes along the Andes Chain (Chungará, Laja, Castor and Venus) were analysed in order to investigate PCB concentrations and distributions in sediment samples. Sediment cores were analysed for PCBs using gas chromatography (GC-ECD/MS) and radioisotopically dated using 210Pb. Organic carbon content (OC) and 210Pb fluxes were also measured. Results showed that sediment PCB concentrations (ngg(-1) d.w.) at Lake Chungará (1.2 +/- 1) in northern Chile, Laja (5 +/- 4) in central, and in Lake Castor (3.5 +/- 4) in southern Chile (the eastern side of the Andes Mountain) were lower than sediments collected from Lake Venus (64 +/- 30) located in southern Chile (the western side) which contained 15-fold higher concentrations of PCBs. The percentage (%) of organic carbon was variable and showed a high range of values in the sediment fluctuating from 2% (Lake Laja) to 22% (Lake Chungará). Analysis of 210Pb fluxes, presented a decrease trend following Lake Laja>Castor>Chungará with a positive correlation with rainfall at each site. Sedimentation rates in Lake Castor (1846 gm(-2)yr(-1)) were higher than at Chungará (748 gm(-2)yr(-1)) and Lake Laja (508 gm(-2)yr(-1)). Focusing factor (FF) is used as a tool to elucidate PCB input in the aquatic ecosystem. FF were lower (<1) for the shallower lakes (Lakes Chungará and Castor). This study provides background levels of PCBs at remote lakes in Chile. Differences in geographical characteristics (orographic effect) might play an important role in the arrival of PCBs, particularly into the southern lakes. PCB fluxes indicated deposition of PCBs in recent sediments is higher than in previous years with peaks of PCB between 1991 and 1998. The continuing increase of PCB inputs in remote Chilean lakes, could be associated with long range atmospheric transport (LRAT).  相似文献   

3.
Concentrations and gas/particle partitioning of PCBs in Chicago   总被引:8,自引:0,他引:8  
Thirty seven air samples were collected in Chicago, IL from June to October 1995 and analyzed for gas and particle concentrations of polychlorinated biphenyls (PCBs). Lower molecular weight (MW) PCBs dominated the samples and on average 95% of the Sigma50PCB concentration (gas+particulate) was in the vapor phase. Sigma50PCB concentrations were classified based on prevailing winds (lake and land). The Sigma50PCB concentration varied between 0.42 and 5.21 ng/m3 (1.80+/-1.70 ng/m3) for lake and 0.53 and 8.31 ng/m3 (2.41+/-2.15 ng/m3) for land wind directions. Back trajectory analyses suggested that SW of Chicago can be an important local or regional source sector for PCBs. Partitioning between gas and particulate phases was modeled using the Junge-Pankow model. The measured particle phase concentrations for low MW PCBs were lower than those predicted by the model while the opposite was observed for high MW PCBs. Plots of gas/particle partition coefficient (log Kp) vs. subcooled liquid vapor pressure (log pL(0)) had reasonable correlations for individual samples but the slope varied among the samples. Samples that originated from over the lake had higher slopes than samples that originated from over the land.  相似文献   

4.
Tasdemir Y  Odabasi M  Holsen TM 《Chemosphere》2007,66(8):1554-1560
A water surface sampler (WSS) was employed in combination with greased surface deposition plates (GSDPs) to measure the particulate dry deposition and gas exchange of polychlorinated biphenyls (PCBs) in Chicago, IL. Vapor phase PCB fluxes were calculated by subtracting the particulate fluxes obtained from GSDPs from total (particulate+gas) fluxes obtained from the WSS. Vapor phase PCB fluxes were divided by ambient air concentrations measured with a high volume sampler to calculate overall gas phase PCB mass transfer coefficients (K(G)). The calculated average PCB MTC was 0.54+/-0.47 cm s(-1). This experimentally determined average gas phase overall mass transfer coefficient, K(G), agreed well with the ones reported from studies using similar techniques and agreed well with modeled values obtained using MTC correlations developed for the WSS.  相似文献   

5.
Airborne particle and gas samples were collected approx every 12 days from April 2002 to June 2006 at the Sterling Nature Center located near the southeast corner of Lake Ontario. These samples were analyzed for polychlorinated biphenyls (PCBs) and dichlorodiphenyltrichloroethane (DDE). Clausius-Clapeyron (C–C) regression analyses of PCBs and DDE yielded moderate correlations (r2 = 0.54, p < 0.001; r2 = 0.74, p < 0.001, respectively) indicating that much of the variations in concentrations can be explained by temperature. Back trajectory analysis indicated that the most important factors driving unusually high PCB partial pressures relative to those predicted by the C–C regression were slow wind speeds and winds generally from the southwest. This combination, which occurred frequently in 2004, increased contact of the air with contaminated upwind surfaces with minimum dilution. Hybrid receptor modeling (Potential Source Contribution Function (PSCF)) results for the total PCBs identified the midwestern US region that contains the urban areas of southern Indiana (IN), southwestern Ohio (OH), and northern Kentucky (KY) having the highest PSCF values. In general urban areas like Chicago (IL), Detroit (MI), Cleveland (OH), St. Louis (MO), and Nashville (TN) also had significant possibilities. In contrast, the PSCF modeling for DDE identified northern Alabama as the area with the highest probability where DDT was applied to cotton fields.  相似文献   

6.
Field data for coarse particulate matter ([PM] PM10) and fine particulate matter (PM2.5) were collected at selected sites in Southeast Kansas from March 1999 to October 2000, using portable MiniVol particulate samplers. The purpose was to assess the influence on air quality of four industrial facilities that burn hazardous waste in the area located in the communities of Chanute, Independence, Fredonia, and Coffeyville. Both spatial and temporal variation were observed in the data. Variation because of sampling site was found to be statistically significant for PM10 but not for PM2.5. PM10 concentrations were typically slightly higher at sites located within the four study communities than at background sites. Sampling sites were located north and south of the four targeted sources to provide upwind and downwind monitoring pairs. No statistically significant differences were found between upwind and downwind samples for either PM10 or PM2.5, indicating that the targeted sources did not contribute significantly to PM concentrations. Wind direction can frequently contribute to temporal variation in air pollutant concentrations and was investigated in this study. Sampling days were divided into four classifications: predominantly south winds, predominantly north winds, calm/variable winds, and winds from other directions. The effect of wind direction was found to be statistically significant for both PM10 and PM2.5. For both size ranges, PM concentrations were typically highest on days with predominantly south winds; days with calm/variable winds generally produced higher concentrations than did those with predominantly north winds or those with winds from "other" directions. The significant effect of wind direction suggests that regional sources may exert a large influence on PM concentrations in the area.  相似文献   

7.
Concentrations of PAHs and PCDD/Fs were measured throughout one year, and PCBs during the second semester, at a rural site in a natural park representative of background pollution in central Italy; results were compared with simultaneous measurements performed at an urban site in Rome 60km away. Twenty-four daily samples were collected at each site by a high-volume PM(10) sampler from February 2000 to January 2001. After ultrasonic extraction and clean-up by TLC, samples were analysed by GC-MS. Mean concentrations of benzo[a]pyrene (BaP, as a marker of carcinogenic PAHs), summation operatorPCDD/Fs and summation operator64 PCBs in Rome were, respectively: 1.1ngm(-3), 65fgWHO-TEQm(-3), 553pgm(-3). The background concentrations were, respectively: 0.016ngm(-3), 3fgWHO-TEQm(-3), and 94pgm(-3). Hence, BaP, and the other PAHs, showed the highest urban-background gradient (two orders of magnitude) and PCBs the lowest. The background pollution levels of BaP and PCDD/Fs were in agreement with the few available background/remote measurements in Europe. In Rome PAHs and PCBs, but not PCDD/Fs, were clearly seasonal; the PCDD/F TEQ was moderately correlated with BaP (P<0.001). At the background site, the seasonality of PAHs was less marked, while it could not be assessed for PCDD/Fs and PCBs. The PCB TEQ accounted for 4% and 15% of total (PCDD/Fs+PCBs) TEQ at the urban and background site, respectively. Mean PM(10) concentration was 54microgm(-3) in Rome and 15microgm(-3) at the background site.  相似文献   

8.
Continental-scale distribution and inter-continental transport of four polychlorinated biphenyl (PCB) congeners (28, 101, 153, 180) from 1950 to 2010 were studied using the global multicompartment chemistry transport model MPI-MCTM. Following identical primary emissions for all PCB congeners into air, most of the burden is stored in terrestrial (soil and vegetation) compartments. Thereby, PCB-28, PCB-101 and PCB-153 show a shift of the soil burden maxima from source to remote regions. This shift is downwind with regard to the westerlies for Eurasia and upwind for North America and more prominent for the lighter PCBs than for PCB-153 or PCB-180. In meridional direction, all congeners' distributions underwent a northward migration in Eurasia and North America since the 1950s. Inter-continental transport from Eurasian sources accounts largely for contamination of Alaska and British Columbia and determines the migration of the PCB distribution in soil in North America. Trans-Pacific transport occurs mainly in the gas phase in boreal winter (December-January-February) at 3-4 km altitude and is on a multi-year time scale strongly linked to the atmospheric pressure systems over the Pacific. Inter-continental transport of the lighter, more volatile PCBs is more efficient than for the heavier PCBs.  相似文献   

9.
The Assessment and Remediation of Contaminated Sediments (ARCS) Program within the U.S. Environmental Protection Agency's Great Lakes National Program Office (GLNPO) contained a component for demonstrating and evaluating sediment remediation technologies. Toward this end, bench-scale tests of solvent extraction, thermal desorption, and wet air oxidation technologies were conducted. Contaminated sediments were tested from the Grand Calumet River, Indiana; Buffalo River, New York; Saginaw River, Michigan; and Ashtabula River, Ohio. The primary contaminants of concern in these sediments were polychlorinated biphenyls (PCBs) and polynuclear aromatic hydrocarbons (PAHs). The solvent extraction tests were conducted with sediments from the Grand Calumet, Buffalo, and Saginaw rivers. The thermal desorption studies were conducted with sediments from the Grand Calumet, Buffalo, and Ashtabula rivers. The wet air oxidation testing was performed with the Grand Calumet River sediment. Raw sediment contaminant concentrations ranged from 0.32-21.9 mg/kg dry mass for PCBs and 2.70-266 mg/kg dry mass for PAHs. PCB removal or destruction efficiencies ranged from approximately 6-99%. PAH removal or destruction efficiencies ranged from 65-99%. Mass balance closures ranged from 40-99% for solids; 59-139% for water; 29-3500% for oil; 16-129% for PCBs; and 69-3170% for PAHs.  相似文献   

10.
We examined the accumulation of PCBs in ospreys (Pandion haleaetus) that were exposed to local sediment sources. Eggs, chick plasma, and sediment samples were collected over a range of 14 km (0.2-14.2 km) from a PCB source in Sturgeon Lake, ON. Sum PCB concentrations declined in chick plasma (range 422.5-58.3 ng/g) as distance from the PCB source increased, but there was a poor relationship with sum PCBs in eggs. Both tissues indicated an Aroclor 1248/1254 source. Aroclor 1254 comprised an average of 66.9% of sum PCBs in chick plasma from Sturgeon Lake, but comprised only from 27.0 to 44.4% in plasma from other Great Lake colonies. Dietary differences among osprey colonies were not sufficient to explain the PCB patterns observed. There was weak evidence that the ability to metabolize PCBs may differ between juveniles and adults, based upon the PCB profile in eggs and chick plasma.  相似文献   

11.
污泥干化芦苇床中的渗滤液水质变化特征   总被引:1,自引:1,他引:0  
对3个中试规模的高有机质剩余污泥干化床中污泥渗滤液水质变化特征进行了为期2年的实验研究。Ⅰ单元作为对照床,未种植植物;Ⅱ单元和Ⅲ单元种植芦苇。Ⅰ单元和Ⅱ单元底部充填炉渣,通过穿孔PVC通风管与大气相连通,目的是通过床体填料空隙提供氧气。3个干化床按照如下周期运行:进泥大约半小时,闲置1周,污泥负荷平均为41.3kg TSS/(m2·a)。实验结果表明,污泥干化芦苇床去除污泥渗滤液中的有机物较传统干化床更有效,通风结构有利于有机物的降解;3个床体的污泥渗滤液总磷浓度均高于进泥,但两个芦苇床渗滤液总磷浓度较低,可能的原因是较传统干化床多了植物吸收作用。根据实验数据分析,3个床体中都发生了氨化、硝化和反硝化作用,单元Ⅲ获得了最高的总氮去除率30.38%,Ⅱ单元和Ⅰ单元获得的总氮去除率分别为25.47%和20.59%。高有机质剩余污泥渗滤液仍含有较高的污染物浓度,需回流至污水处理单元进行进一步处理。  相似文献   

12.
Abstract

Field data for coarse particulate matter ([PM] PM10) and fine particulate matter (PM2.5) were collected at selected sites in Southeast Kansas from March 1999 to October 2000, using portable MiniVol particulate samplers. The purpose was to assess the influence on air quality of four industrial facilities that burn hazardous waste in the area located in the communities of Chanute, Independence, Fredonia, and Coffeyville. Both spatial and temporal variation were observed in the data. Variation because of sampling site was found to be statistically significant for PM10 but not for PM2.5. PM10 concentrations were typically slightly higher at sites located within the four study communities than at background sites. Sampling sites were located north and south of the four targeted sources to provide upwind and downwind monitoring pairs. No statistically significant differences were found between upwind and downwind samples for either PM10 or PM2.5, indicating that the targeted sources did not contribute significantly to PM concentrations. Wind direction can frequently contribute to temporal variation in air pollutant concentrations and was investigated in this study. Sampling days were divided into four classifications: predominantly south winds, predominantly north winds, calm/variable winds, and winds from other directions. The effect of wind direction was found to be statistically significant for both PM10 and PM2.5. For both size ranges, PM concentrations were typically highest on days with predominantly south winds; days with calm/variable winds generally produced higher concentrations than did those with predominantly north winds or those with winds from “other” directions. The significant effect of wind direction suggests that regional sources may exert a large influence on PM concentrations in the area.  相似文献   

13.
Priority organic pollutant assessment of sludges for agricultural purposes   总被引:2,自引:0,他引:2  
A comprehensive characterization of five of the seven priority organic pollutants listed in the draft of the "Working document on sludge" [EU, 2000. Working Document on Sludge 3rd Draft. Unpublished, 19 p] has been carried out during 2001-2003 in sludge samples from Catalonia (NE Spain). One hundred and thirty-nine samples belonging to 20 Waste Water Treatment Plants (WWTPs), seven sludge treatment (thermal drying) and three composting sludge plants were taken in order to determine the concentration of polychlorinated dibenzo-p-dioxins and -furans (PCDD/Fs), di-2-(ethyl-hexyl)-phthalate (DEHP), nonylphenol and nonylphenol ethoxylates with one or two ethoxy groups (NPE), polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). PCDD/F concentrations were in general lower than the 100 ng I-TEQ/kg limit suggested in the above-mentioned document. In the same way, 98.5% for PCBs, 97% for PAH and 92.8% for DEHP of the samples presented concentrations lower than 0.8 mg/kg dm, 6 mg/kg dm and 100 mg/kg dm, respectively. In contrast, the vast majority of samples contained NPE concentrations much higher than 50mg/kg dm limit. The values ranged from 14.3 to 3150 mg/kg dm (median value=286.6 mg/kg) being composted sludge samples the less contaminated ones (17.9-363.4 mg/kg dm; median value=89.3 mg/kg). Special attention should be paid to the Catalan sludge NPE contamination owing to the high levels detected.  相似文献   

14.
Ambient concentrations, congener patterns and multi-media distribution of PCDD/Fs and PCBs were determined in air, water, sediment and mussels in a semi-enclosed marine ecosystem (Thau lagoon, France). summation operator2,3,7,8-PCDD/F and summation operator7ICES PCB air concentrations (0.2-1.4 and 31-57pg m(-3), respectively) were typical of rural areas. Concentrations in the water column were very low for PCDD/Fs (163-476fg L(-1)) and low for PCBs (138-708pg L(-1)). PCDD/F and PCB concentrations found in surface sediment (0.15-1.6 and 2.5-33ng g(-1) d.w., respectively) and mussel (13-21pg g(-1) d.w. and 10-39ng g(-1) d.w., respectively) were medium levels. PCDD/F congener patterns observed in air, water particulate phase and sediments were similar suggesting direct coupling among these compartments and atmospheric inputs of PCDD/Fs into the lagoon. Conversely, for the same set of samples, similar patterns were not observed for PCBs in the mentioned compartments.  相似文献   

15.
Settling particles and underlying sediments collected at 1, 2.5 and 4 km along offshore transects in the urbanized sector of the Río de la Plata were analyzed to evaluate the sources and accumulation of PCBs. Total PCB concentrations range from <0.1 to 100 ng g(-1) and include variability associated to North-South and offshore gradients reflecting the impact of coastal discharges. Highest concentrations were recorded in the industrialized Central area close to Buenos Aires (61+/-37 ng g(-1) at 1 km) relative to cleaner northern stations (3.6+/-2.2 ng g(-1)) and southward sites (37+/-2.8 ng g(-1)), affected by transport of particulate PCBs by coastal currents. Sediment traps deployed in the Central area revealed large depositional fluxes of total matter (361+/-124 gm(-2)day(-1)) and PCBs (26+/-19 microg m(-2)day(-1)) and high sedimentation rates (5.0+/-1.7 cm yr(-1)). Uniform PCB concentrations (66-89 ng g(-1)) down to 20 cm in sediment cores suggest continued PCB discharges during the last 4 years. PCB composition was dominated by hexa (43+/-6.4%), hepta (23+/-5.1%) and pentachlorobiphenyls (21+/-5.5%) with lower proportions tri-tetra (7.4+/-5.4%) and higher chlorinated congeners (5.1+/-3.3%). A consistent weathering pattern with loss of 3-5 chlorobiphenyls and enrichment in higher chlorinated PCBs corresponding to a shift from a 1:1 to a 1:3 1254:1260 Aroclor mixture, was observed offshore. A principal component analysis performed with the relative contribution of PCB congener classes confirmed the offshore weathering pattern indicating that transformer oils containing Aroclor 1254-1260 are the most probable sources. Sediment inventories, sediment trap fluxes and Fugacity II calculations indicate an accumulation approximately 500-800 kg PCB in superficial sediments of this coastal environment.  相似文献   

16.
Li X  Zhang Q  Dai J  Gan Y  Zhou J  Yang X  Cao H  Jiang G  Xu M 《Chemosphere》2008,72(8):1145-1151
Organochlorine pesticides (OCPs, including DDT, HCH and HCB) and six indicator polychlorinated biphenyls (PCB 28, 52, 101, 138, 153, and 180) were measured in water, sediment, zooplankton, fish and Chinese softshell turtle (Pelodiscus sinensis) from Gaobeidian Lake, which is located in the effluent of Gaobeidian wastewater treatment plant (WWTP) in Beijing, China. DDTs were dominant except for in water. In water, the concentrations of DDTs (6.22 ng l(-1)) and HCHs (18.0 ng l(-1)) were less than the limits (l000 ng l(-1) for DDTs and 5000 ng l(-1) for HCHs). However, PCBs concentration (20.8 ng l(-1)) exceeded the limit (14 ng l(-1)) suggested by the United States Environmental Protection Agency (USEPA). The high ratio of p,p'-DDT/DDTs (0.80) in water suggested that DDTs had recently been discharged into the ambient environment despite a longtime ban in China. For fish and Pelodiscus sinensis, the accumulation patterns of OCPs and PCBs were different in muscle and liver. And HCB and PCB 153 were significant different in different species (p<0.05). PCBs were dominated by PCB 52 in zooplankton, but by PCB 138 and 153 in Pelodiscus sinensis. The highest food web magnification factor (FWMF) was 4.83 for p,p'-DDT and the second highest was 4.36 for PCB 101 in Gaobeidian Lake. As compared with the other studies, biomagnification in the present study was not obvious. Trophic levels and age were two important factors that might contribute to the bioaccumulation in the present study.  相似文献   

17.
Atmospheric PCB congeners across Chicago   总被引:1,自引:0,他引:1  
We have measured PCBs in 184 air samples collected at 37 sites in the city of Chicago using an innovative system of high-volume air samplers mounted on two health clinic vans. Here we describe results of sampling conducted from November 2006 to November 2007. The samples were analyzed for all 209 PCB congeners using a gas chromatograph with tandem mass spectrometry (GC-MS/MS). The ΣPCBs (sum of 169 peaks) in Chicago ranged from 75 pg m(-3) to 5500 pg m(-3) and primarily varied as a function of temperature. The congener patterns are surprisingly similar throughout the city even though the temperature-corrected concentrations vary by more than an order of magnitude. The average profile resembles a mixture of Aroclor 1242 and Aroclor 1254, and includes many congeners that have been identified as being aryl hydrocarbon receptor (AhR) agonists (dioxin-like) and/or neurotoxins. The toxic equivalence (TEQ) and neurotoxic equivalence (NEQ) in air were calculated and investigated for their spatial distribution throughout the urban-industrial complex of Chicago. The NEQ concentrations are linearly correlated with ΣPCBs while the TEQ concentrations are not predictable. The findings of this study suggest that airborne PCBs in Chicago are widely present and elevated in residential communities; there are multiple sources rather than one or a few locations of very high emissions; the emission includes congeners associated with dioxin-like and neurotoxic effects and congeners associated with unidentified sources.  相似文献   

18.
Research on the environmental fate and transport of PCBs in Lake Ontario basin depends, among other aspects, on the availability of representative data sets for upstream sources, but data are lacking for most US Lake Ontario tributaries. In this study, water samples were collected between September 2004 and October 2008 from five tributaries and were analyzed for 209 polychlorinated biphenyls (PCB) with high-resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) following EPA Method 1668A. Total PCB concentrations ranged between 0.31 and 42.75 ng L−1. Congeners between Di and Hexa PCBs accounted between 70 and 99% of the total PCB. The tributary with highest PCB concentrations presented similar pattern and percentage levels to Aroclor 1242. Total average loads for the sampling events ranged between 1.85 g d−1 and 59.08 g d−1. PCB concentrations were evaluated against other variables and other studies (including different matrices) to better understand their transport. The methodology used is reliable to assess PCB contamination in surface water.  相似文献   

19.
Evidence for destruction of PCBs by the OH radical in urban atmospheres   总被引:3,自引:0,他引:3  
Evidence for reaction of polychlorinated biphenyl (PCB) congeners with the hydroxyl (OH) radical in the troposphere was observed in diurnal variations in ambient gas-phase PCB concentrations at three urban sampling sites located in the Chicago, IL; Baltimore, MD; and Jersey City, NJ urban/industrial areas. The magnitude of the depletion of individual PCB congeners decreased by about 10-20% for each additional chlorine substituent, reflecting slower reaction rates for higher MW congeners with the OH radical. Octa- and nonachlorobiphenyls, which are largely unreactive with the OH radical, were used as tracers to investigate the effects of dilution on diurnal variation. The environmental rate constants for disappearance of the PCBs range from about 1.0 day(-1) for trichlorobiphenyls to about 0.3 day(-1) for hexachlorobiphenyls. Assuming a OH radical concentration of 3 x 10(6) molecules cm (-3), the second-order rate constants for reaction of specific congeners with the OH radical are consistent with laboratory measurements. More importantly, the relative reactivity of PCB homologues agrees well with the relationship predicted by other researchers from laboratory measurements, suggesting that losses of PCBs during daytime tropospheric transport are due at least in part to reactions with the OH radical.  相似文献   

20.
We examined 2,046 adults (834 males and 1,212 females aged 20-75 years) from polluted district in East Slovakia (POLL) and two neighboring upstream and upwind located districts of background pollution (BCGR). By ultrasound we estimated the thyroid volume (ThV), hypoechogenicity (HYE), nodules and cysts. Serum levels of thyrotropin (TSH), thyroperoxidase antibodies (TPOab) and thyroglobulin were estimated by electrochemiluminiscent assay and these of 15 PCB congeners, p,p'-DDE, p,p'-DDT, hexachlorobenzene (HCB) and hexachlorocyclohexane by high-resolution gas chromatography. In 320 subjects also selected hydroxylated and methylsulfonated PCB metabolites, polychlorinated dibenzo-dioxins (PCDDs), -furans (PCDFs), five dioxin-like coplanar and eight mono-ortho PCB congeners were estimated. Urinary iodine was measured by automatic microplate method. Reciprocal positive association was found between three major POPs (PCBs, DDE and HCB), the levels of these and also PCDDs plus PCDFs in polluted area being considerably higher than in background pollution area. ThV in groups of males and females from POLL with high PCBs level was significantly higher (p<0.001 by t-test) then in age and sex matched groups from BCGR with low PCBs level. In 1,048 males and females aged <60 years with serum PCBs level >1,000 ng g(-1) lipid (median=1,756 ng g(-1)) a significant effect of age on ThV was found (p<0.01 by ANOVA), while in 921 respective subjects with PCBs level <1,000 ng g(-1) (median=661 ng g(-1)) it was not. These findings supported the view on the additional effect of PCBs on ThV other than that of age. Since the urinary iodine in both districts showed optimal range, any interfering effect of unsatisfactory iodine intake on ThV may be excluded. The frequency of autoimmune thyroiditis signs such as HYE, increased serum level of TPOab and TSH resulting in subclinical or overt thyroid hypofunction was positively associated with sex, age and organochlorine levels. The increase of such frequency in males with POPs levels was much more abrupt than that in females. No considerable differences in the frequency of thyroid nodules as related to PCBs level were found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号