首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Anaerobic/aerobic treatment of meat processing wastewater   总被引:2,自引:0,他引:2  
The meat processing industry is believed to produce highly polluted wastewater. Analysis of such wastewater indicated that the waste was highly contaminated with organic compounds as indicated by COD (1544mgO2l–1), BOD (646mgO2l–1), and TSS (1155 mgl–1). Moreover, oil and grease concentrations reached 144mgl–1 treatment of raw wastewater using Upflow Anaerobic Sludge Blanket (UASB) followed by Rotating Biological Contactors (RBC) was studied. Efficiency of the UASB for the removal of CODtotal, BODtotal, TSS, and oil and grease was 56%, 56%, 85%, and 58%, respectively. The quality of the UASB effluent barely complies with the regulatory standards for discharging wastewater into the sewerage network. UASB effluent was subjected for further treatment using a RBC unit to improve the quality of the treated effluent for reuse in irrigation purposes. Residual COD, BOD, TSS, and oil and grease, following RBC, was 132mgO2l–1, 40mgO2l–1, 44mgl–1, and 10mgl–1 respectively. The overall efficiency of the treatment units provided good quality effluent. The overall percentage removal of COD, BOD, TSS, and oil and grease was 91.5%, 94%, 96%, and 91%, respectively. Based on the quality of the treated effluent and guidelines recommended for wastewater reuse, it may be concluded that a slight to moderate restricted irrigation is applicable to reuse the treated effluent in the green belt around the factory. Disinfection should be applied to ensure the safety of such a process.  相似文献   

2.
Treatment and reuse of sewage sludge   总被引:2,自引:0,他引:2  
Sewage sludge was treated using composting, fixed-bed and stirred anaerobic digesters. The treatment performance in terms of the physico chemical parameters, bacterial indicators and pathogenic forms were assessed. In addition, the biogas production rate was recorded in the case of anaerobic digesters. Composting of the sewage sludge increased its total solids from 39 to 93% after 6 weeks, while the reduction in organic matter was 40% and the total nitrogen and phosphorus contents increased by 22 and 30%, respectively. Complete removal of salmonellae and faecal coliforms occurred, so that the composted sludge could be used as a soil conditioner and fertilizer. The results of the anaerobic treatment indicated that an organic load of 4.8kg COD m–3 per day achieved the best operating conditions for either the stirred or fixed-bed digester. The mean percentage removals of COD, BOD, faecal coliforms, faecal streptococci and the biogas production rate for the stirred digester were 53, 53, 24 and 29% and 259 L kg–1 COD per day, respectively. The corresponding mean percentage removals and production rate for the experiments with a fixed-bed digester were 61, 62, 33 and 35% and 328 L kg–1 COD per day, respectively. Improvements in the BOD and faecal coliform reductions and the gas production rate of 17, 38 and 21%, respectively, were achieved due to the presence of media (Berl saddles) in the fixed-bed digester. The microbial content of the anaerobically treated sludge is too high to be used as a fertilizer, while that of the composted sludge is low enough for such use.  相似文献   

3.
Summary This study is carried out to propose an appropriate treatment technology for wastewater discharged from a flavor production factory. Industrial wastewater discharged from this factory ranges between 50–70 m3/d with an average value of 60 m3/d. The major source of pollution in this factory is due to cleaning of the vessels therefore the treatment has been carried out on the end-of pipe wastewater. The wastewater is characterized by high values of COD, BOD, TSS and Oil and grease 4646, 2298, 1790 and 626 mg/l respectively. Primary sedimentation of the wastewater for four hours reduced the COD, BOD, TSS and Oil and grease by 43, 47, 80 and 74%, respectively. For the treatment of the produced wastewater, the biological treatment process such as activated sludge, rotating biological contactor (RBC), up-flow anaerobic sludge bed reactor (UASB) have been selected. The results from each treatment process proved to be efficient for the treatment of such wastewater. The treated wastewater characteristics are in compliance with the Egyptian law which regulates the discharge of industrial wastewater to the sewerage system. The RBC was selected and installed by the factory as it has the advantage of low operating and maintenance costs. The factory RBC performance was monitored; characteristics of the treated effluent in terms of oil and grease, COD, BOD and TSS were 27, 362, 139 and 95 mg/l, respectively.  相似文献   

4.
A study was conducted to evaluate the performance of six advanced wastewater treatment facilities using biological nutrient removal processes as the primary mechanism for removing carbon, nitrogen, and phosphorus from domestic wastewater. One year of operating data was obtained from monthly operating reports provided by the Georgia Environmental Protection Division (EPD) in Atlanta. Additional information about facility operations and the types of chemicals used was gathered through review of EPD files and interviews with plant personnel. Data evaluated were: influent and effluent five-day Biochemical Oxygen Demand (BOD(5)); influent and effluent total suspended solids (TSS); influent Total Kjeldahl Nitrogen and effluent Total Nitrogen; and influent and effluent Total Phosphorus (TP). Although varying from plant to plant, effluent requirements for BOD(5), TSS, ammonia, and TP were met. Chemicals utilized, design capacity, and monthly effluent concentrations are presented in this study.  相似文献   

5.
The production of highly polluting palm oil mill effluent (POME) has resulted in serious environmental hazards. While anaerobic digestion is widely accepted as an effective method for the treatment of POME, anaerobic treatment of POME alone has difficulty meeting discharge limits due to the high organic strength of POME. Hence, subsequent post-treatment following aerobic treatment is vital to meet the discharge limits. The objective of the present study is to investigate the aerobic treatment of anaerobically digested POME by using a sequencing batch reactor (SBR). The SBR performance was assessed by measuring Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD) and Total Suspended Solids (TSS) removal as well as Sludge Volume Index (SVI). The operating pH and dissolved oxygen concentrations were found to be 8.25–9.14 and 1.5–6.4 mg/L, respectively, throughout the experiment. The experimental results demonstrate that MLVSS, OLR and sludge loading rate (SLR) play a significant role in the organic removal efficiency of SBR systems and therefore, further investigation on these parameters was conducted to attain optimum SBR performance. Maximum COD (95–96%), BOD (97–98%) and TSS (98–99%) removal efficiencies were achieved at optimum OLR, SLR and MLVSS concentration ranges of 1.8–4.2 kg COD/m3 day, 2.5–4.6 kg TSS/m3 day and 22,000–25,000 mg/L, respectively. The effluent quality remained stable and complied with the discharge limit. At the same time, the sludge showed good settling properties with average SVI of 65. It is envisaged that the SBR process could complement the anaerobic treatment to produce final treated effluent which meets the discharge limit.  相似文献   

6.
Overland flow (OF) systems were evaluated and compared for advanced treatment of municipal and industrial effluents, including nutrients and nondegradable chemical oxygen demand (COD) removal. Three pilot plants were constructed at the Shahin Shahr Wastewater Treatment Plant (WWTP), Isfahan, Iran. Each pilot was assigned a specific wastewater and all were simultaneously operated for 8 months. Treatment of primary effluent, activated sludge secondary effluent, and lagoon effluent of textile wastewater was investigated at application rates (ARs) of 0.15, 0.25, and 0.35m(3)m(-1)h(-1). During 5 months of stable operation after a 3-month acclimation period, mean removals of total 5-day biochemical oxygen demand (TBOD(5)), total COD (TCOD), total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and turbidity were 74.5%, 54.8%, 66.2%, 39.4%, 35.8%, and 67.7% for primary effluent; 52.9%, 52.9%, 66.5%, 44.4%, 39.8%, and 50.1% for activated sludge effluent; 65.7%, 58.7%, 70.3%, 41.7%, 41.3%, and 54.9% for textile wastewater lagoon effluent, respectively. The model of Smith and Schroeder, 1985. Field studies of the overland flow process for the treatment of raw and primary treated municipal wastewater. Journal of Water Pollution Control Federation 57, 785-794] was satisfactory for TBOD(5). For all treatment parameters a standard first-order removal model was inadequate to represent the data but a modified first-order model provided a satisfactory fit to the data. Based on the results of this study, it can be concluded that an OF system as advanced treatment had the ability to meet effluent discharge permit limits and was an economical replacement for stabilization ponds and mechanical treatment options.  相似文献   

7.
The aim of present study was to investigate the quality of the produced effluent from different units of the Iran Central Iron Ore in Bafq city and comparison of effluent with the standards. This study presents the physicochemical and biological parameters data of effluent of three Sequencing batch reactors (SBR) with a capacity of 160 m3?d?1. Most common parameters include pH, total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP), biochemical oxygen demand (BOD5), chemical oxygen demand (COD), heavy metals, and total coliforms and fecal coliforms as biological indicators. Then, for each SBR system, the average of each parameter was determined, and results were compared with the standard recommended by the Iranian Environmental Protection Agency. Based on the results, some of the parameters, including BOD5, COD, and TSS in the wastewater treatment plant (WWTP) effluent, are higher than the permitted amount for discharge to the surface water. Considering the BOD5, COD, and TSS concentration in WWTPs, the treated wastewater is only suitable for agricultural and irrigation use. Therefore, wastewater produced by Iran Central Iron Ore Co. will need additional treatment to achieve standard quality of water before discharge in surface water and adsorbent well.  相似文献   

8.
微生物菌剂在酿酒废水处理中的应用研究   总被引:6,自引:1,他引:5  
采用厌氧-好氧工艺,结合微生物菌剂对酿酒废水进行了处理研究。进水CODCr浓度可达到8,456.3-22,442.0mg/L,BOD55,040.0-9.557.1mg/L,pH3-4,可不调pH,采用微生物菌剂接种可启动厌氧反应器,COD有机负荷最高达到10.2gCOD/Ld,COD去除率稳定在91-95%,BOD去除率90-94%,出水pH6.6-7.1,出水CODCr在2,000mg/L以下,BOD5800mg/L以下。厌氧污泥可全部颗粒化。好氧处理系统中接种微生物菌剂,曝气10-12小时,可保证出水中CODCr在230mg/L以下,甚至直接达到国家一级排放标准。微生物菌剂的应用是取得该处理效果的关键。  相似文献   

9.
Combined chemical and biological oxidation of penicillin formulation effluent   总被引:12,自引:0,他引:12  
Antibiotic formulation effluent is well known for its important contribution to environmental pollution due to its fluctuating and recalcitrant nature. In the present study, the chemical treatability of penicillin formulation effluent (average filtered COD(o)=830 mg/l; average soluble COD(o)=615 mg/l; pH(o)=6.9) bearing the active substances penicillin Amoxicillin Trihydrate (C(16)H(19)N(3)O(5)S.3H(2)O) and the beta-lactamase inhibitor Potassium Clavulanate (C(8)H(8)KNO(5)) has been investigated. For this purpose, the penicillin formulation effluent was subjected to ozonation (applied ozone dose=2500 mg/(lxh)) at varying pH (2.5-12.0) and O(3)+H(2)O(2) (perozonation) at different initial H(2)O(2) concentrations (=2-40 mM) and pH 10.5. According to the experimental results, the overall Chemical Oxygen Demand (COD) removal efficiency varied between 10 and 56% for ozonation and 30% (no H(2)O(2)) and 83% (20 mM H(2)O(2)) for the O(3)+H(2)O(2) process. The addition of H(2)O(2) improved the COD removal rates considerably even at the lowest studied H(2)O(2) concentration. An optimum H(2)O(2) concentration of 20 mM existed at which the highest COD removal efficiency and abatement kinetics were obtained. The ozone absorption rate ranged between 53% (ozonation) and 68% (perozonation). An ozone input of 800 mg/l in 20 min was sufficient to achieve the highest BOD(5)/COD (biodegradability) ratio (=0.45) and BOD(5) value (109 mg/l) for the pre-treated penicillin formulation effluent. After the establishment of optimum ozonation and perozonation conditions, mixtures of synthetic domestic wastewater+raw, ozonated and perozonated penicillin formulation effluent were subjected to biological activated sludge treatment at a food-to-microorganisms (F/M) ratio of 0.23 mg COD/(mg MLSSxd), using a consortium of acclimated microorganisms. COD removal efficiencies of the activated sludge process were 71, 81 and 72% for pharmaceutical wastewater containing synthetic domestic wastewater mixed with either raw, ozonated or perozonated formulation effluent, respectively. The ultimate COD value obtained after 24-h biotreatment of the synthetic domestic wastewater+pre-ozonated formulation effluent mixture was around 100 mg/l instead of 180 mg/l which was the final COD obtained for the wastewater mixture containing raw formulation effluent, indicating that pre-ozonation at least partially removed the non-biodegradable COD fraction of the formulation effluent.  相似文献   

10.
Eight small-scale municipal wastewater treatment plants were evaluated over a period of 19 months in the suburb of Las Rozas in Madrid (Spain). Four plants used compact extended aeration, two used conventional activated sludge, two used conventional extended aeration, one used a rotary biodisc reactor and the other used a peat bed reactor. The best results were obtained from the plants that used conventional technologies and the biodisc. Conventional activated sludge and extended aeration had higher removal efficiencies for ammonia, TSS, COD and BOD(5) and produced good quality final effluents for final disposal in accordance with the discharge standard. Empirical equations that correlated the concentration of dissolved oxygen in the effluents with the efficiencies of TSS, ammonia, COD and BOD(5) removals for all plants evaluated were obtained. The performance of the plants using compact extended aeration was affected more than those using conventional technologies or rotary biodisc when the capacity exceeded that of its initial design.  相似文献   

11.
This study focuses on a lab-scale rotating biological contactor (RBC) treating vegetable oil wastewater with high BOD and COD. The fabricated RBC was checked for efficiency in degrading polluted wastewater under different operating conditions. The maximum removal efficiencies for BOD and COD were 95.75% and 89%, respectively. This high removal percentage was obtained with 30% submergence of 10 discs rotating at 8 rpm. For the first time, bio-kinetic models were applied to the experimental results for vegetable oil wastewater. The best fit was obtained with the modified Stover-Kincannon and Grau model. The saturation constant (Ks) values were 1.872 and 3.024 g/L/d for BOD and COD, respectively, for the modified Stover-Kincannon and Grau model. For the Grau second-order model, the saturation constant was 1.416 and 3.744 g/L/d for BOD and COD, respectively. The predicted effluent BOD and COD values of the modified Stover–Kincannon model fitted almost exactly with the experimental values. This clearly predicts that this model can be best used to predict effluent BOD and COD concentration in a Rotating Biological contactor treating vegetable oil wastewater. The kinetic parameters determined in this study can be used to improve the design and operation of continuous mode RBC systems.  相似文献   

12.
Treatment of low-strength soluble wastewater (COD approximately 500 mg/L) was studied using an eight chambered anaerobic baffled reactor (ABR). At pseudo steady-state (PSS), the average total and soluble COD values (COD(T) and COD(S)) at 8h hydraulic retention time (HRT) were found to be around 50 and 40 mg/L, respectively, while at 10h HRT average COD(T) and COD(S) values were of the order of 47 and 37 mg/L, respectively. COD and BOD (3 day, 27 degrees C) removal averaged more than 90%. Effluent conformed to Indian standards laid down for BOD (less than 30 mg/L). Reactor effluent characteristics exhibited very low values of standard deviation indicating excellent reactor stability at PSS in terms of effluent characteristics. Based on mass balance calculations, more than 60% of raw wastewater COD was estimated to be recovered as CH(4) in the gas phase. Compartment-wise profiles indicated that most of the BOD and COD got reduced in the initial compartments only. Sudden drop in pH (7.8-6.7) and formation of volatile fatty acids (VFA) (53-85 mg/L) were observed in the first compartment due to acidogenesis and acetogenesis. The pH increased and VFA concentration decreased longitudinally down the reactor. Residence time distribution (RTD) studies revealed that the flow pattern in the ABR was neither completely plug-flow nor perfectly mixed. Observations from scanning electron micrographs (SEM) suggest that distinct phase separation takes place in an ABR.  相似文献   

13.
Treatment of chemical industrial wastewater from building and construction chemicals factory and plastic shoes manufacturing factory was investigated. The two factories discharge their wastewater into the public sewerage network. The results showed the wastewater discharged from the building and construction chemicals factory was highly contaminated with organic compounds. The average values of chemical oxygen demand (COD) and biochemical oxygen demand (BOD) were 2912 and 150 mgO2/l. Phenol concentration up to 0.3 mg/l was detected. Chemical treatment using lime aided with ferric chloride proved to be effective and produced an effluent characteristics in compliance with Egyptian permissible limits. With respect to the other factory, industrial wastewater was mixed with domestic wastewater in order to lower the organic load. The COD, BOD values after mixing reached 5239 and 2615 mgO2/l. The average concentration of phenol was 0.5 mg/l. Biological treatment using activated sludge or rotating biological contactor (RBC) proved to be an effective treatment system in terms of producing an effluent characteristic within the permissible limits set by the law. Therefore, the characteristics of chemical industrial wastewater determine which treatment system to utilize. Based on laboratory results engineering design of each treatment system was developed and cost estimate prepared.  相似文献   

14.
This paper addresses the treatment of purified terephthalic acid (PTA) effluent using anaerobic and aerobic processes. Laboratory studies were carried out on flow proportionate composite wastewater generated from the manufacturing of PTA. An activated sludge process (ASP-two stage and single stage) and an upflow anaerobic fixed film fixed bed reactor (AFFFBR) were used, individually and in combination. The performance of a full-scale ETP under existing operating conditions was also studied. Full scale ETP studies revealed that the treatment of PTA effluent using a two-stage ASP alone does not meet treated effluent quality within the prescribed Indian Standards. The biomass produced in the two stage ASP was very viscous and fluffy and the sludge volume index (SVI) was very high (200-450 ml/g). However, pretreatment of PTA effluent using an upflow AFFFBR ensured substantial reduction in BOD (63%) and COD (62%) with recovery of biogas at 1.8-1.96 l/l effluent treated at a volumetric loading rate (VLR) 4-5 kg COD/m(3) d. The methane content in the biogas varied between 55% and 60%. The pretreated effluent from the upflow AFFFBR was then treated through a single stage ASP. The biomass produced in the ASP after anaerobic treatment had very good settlability (SVI: 75-90 ml/g) as compared to the two stage ASP and the treated effluent quality with respect to BOD, COD and SS was within the prescribed Indian Standards. The alternative treatment process comprising an upflow AFFFBR and a single stage ASP ensured net power saving of 257 kW and in addition generated 442 kW of power through the AFFFBR.  相似文献   

15.
针对目前二级城市污水处理厂工程投资高、运行费用高的特点,提出适合中小城市污水处理的工艺——高负荷活性污泥法(HAS)。该工艺不设初次沉淀池,负荷高,泥龄短,污泥沉降性能良好,不存在污泥膨胀,对有机物的去除以絮凝、吸附、沉淀作用为主,对COD、BOD,、SS都有较高的去除效果,对氮、磷有一定的去除作用,出水水质可满足《农田灌溉水质标准》的要求。  相似文献   

16.
A reliable model for any wastewater treatment plant is essential in order to provide a tool for predicting its performance and to form a basis for controlling the operation of the process. This would minimize the operation costs and assess the stability of environmental balance. This process is complex and attains a high degree of nonlinearity due to the presence of bio-organic constituents that are difficult to model using mechanistic approaches. Predicting the plant operational parameters using conventional experimental techniques is also a time consuming step and is an obstacle in the way of efficient control of such processes. In this work, an artificial neural network (ANN) black-box modeling approach was used to acquire the knowledge base of a real wastewater plant and then used as a process model. The study signifies that the ANNs are capable of capturing the plant operation characteristics with a good degree of accuracy. A computer model is developed that incorporates the trained ANN plant model. The developed program is implemented and validated using plant-scale data obtained from a local wastewater treatment plant, namely the Doha West wastewater treatment plant (WWTP). It is used as a valuable performance assessment tool for plant operators and decision makers. The ANN model provided accurate predictions of the effluent stream, in terms of biological oxygen demand (BOD), chemical oxygen demand (COD) and total suspended solids (TSS) when using COD as an input in the crude supply stream. It can be said that the ANN predictions based on three crude supply inputs together, namely BOD, COD and TSS, resulted in better ANN predictions when using only one crude supply input. Graphical user interface representation of the ANN for the Doha West WWTP data is performed and presented.  相似文献   

17.
The operational parameter MRT%FE, representing the mean residence time of different ages fractions of effluent within a completely mixed reactor, was evaluated and integrated with first order kinetics. The parameter was used to model Escherichia coli concentrations in a municipal wastewater reservoir managed under different operating conditions (continuous and discontinuous). The study was conducted during 2004-2005 in a reservoir receiving effluents from the activated sludge treatment plant of Caltagirone (Eastern Sicily - Italy). The analytical approach is applied to the hydraulic state variables of the system (daily stored volumes, inlet and outlet flows), and the physical-chemical (pH, temperature, EC, TSS, BOD(5), COD) and bacteriological wastewater parameters (E. coli, FC, FS). In order to evaluate the reliability of the proposed approach, predicted E. coli concentrations within the reservoir were compared with measured ones by the correlation coefficient, F-test and Sperman's index. The study included the evaluation of die-off coefficient K(T) (d(-1)), light extinction coefficient K (m(-1)) and their relationships with climatic factors. Results of the study confirm that E. coli removal is related to the fractions of fresh effluent remaining each day within the reservoir with MRT%FE of about 5-8d, significantly lower than the nominal detention time (about 27d). The E. coli die-off coefficient (K(T)) was higher during system discontinuous operations and correlated with incident solar radiation and water temperature.  相似文献   

18.
Earthworms’ body works as a ‘biofilter’ and they have been found to remove the 5 days’ BOD (BOD5) by over 90%, COD by 80–90%, total dissolved solids (TDS) by 90–92%, and the total suspended solids (TSS) by 90–95% from wastewater by the general mechanism of ‘ingestion’ and biodegradation of organic wastes, heavy metals, and solids from wastewater and also by their ‘absorption’ through body walls. Earthworms increase the hydraulic conductivity and natural aeration by granulating the clay particles. They also grind the silt and sand particles, increasing the total specific surface area, which enhances the ability to ‘adsorb’ the organics and inorganic from the wastewater. Intensification of soil processes and aeration by the earthworms enable the soil stabilization and filtration system to become effective and smaller in size. Suspended solids are trapped on top of the vermifilter and processed by earthworms and fed to the soil microbes immobilized in the vermifilter. There is no sludge formation in the process which requires additional expenditure on landfill disposal. This is also an odor-free process and the resulting vermifiltered water is clean and disinfected enough to be reused for farm irrigation and in parks and gardens G. Bharambe—GU & Research Assistant (Under Rajiv K. Sinha), U. Chaudhari—GU (Worked on vermiculture project).  相似文献   

19.
This paper investigates the removal of coliforms in full-scale activated sludge plants (ASP) operating in northern regions of India. Log2.2 and log2.4 removal were observed for total coliforms (TC) and fecal coliforms (FC), respectively. However, the effluent still contained a significant number of TC and FC which was greater than the permissible limit for unrestricted irrigation as prescribed by WHO. The observations also suggest that extended aeration (EA) process operating under high mixed liquor suspended solids (MLSS) and sludge retention time (SRT) is more efficient in the removal of coliforms. Further attempts have been made to establish the relationship between two key wastewater parameters, i.e. biochemical oxygen demand (BOD) and suspended solids (SS) with respect to fecal and TC. The relationships were observed to be linear with a good coefficient of correlation. The interrelationship of BOD and SS with coliforms manifest that improvement of the microbiological quality of wastewater could be linked with the removal of SS. Therefore, SS can serve as a regulatory tool in lieu of an explicit coliforms standard.  相似文献   

20.
山海关区新民居污水治理工程采用水解酸化+接触氧化+曝气生物滤池为主的工艺进行污水治理,实际运行结果表明:系统运行稳定,处理出水COD≤48 mg.L-1,BOD5≤9 mg.L-1,SS≤10 mg.L-1,NH3-N≤4.5 mg.L-1,TP≤0.47 mg.L-1,处理出水达到《城镇污水处理厂污染物排放标准》(GB 18918-2002)一级A标准,出水用于农村绿化和农灌,经济效益和环境效益明显。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号