首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
A novel bioaugmentation scheme called immobilized-cell-augmented activated sludge (ICAAS) was developed. Offline enricher reactors were used to maintain immobilized acclimated cells applied to augment completely mixed activated sludge (CMAS) treating a pentachlorophenol (PCP) pulse loading. Cellulose triacetate (CA) and powder activated carbon (PAC) combined with CA (PAC + CA) were the two media types used for entrapping the PCP-degrading culture. With ICAAS at 5% by volume augmentation, PCP removal of 73.1 and 75.1% via biodegradation, volatilization, and adsorption onto suspended cells, entrapped cells, and media was achieved for the systems with CA and PAC + CA media, respectively, while PCP removal in a control CMAS, which had a comparable level of combined PCP adsorption onto suspended cells and volatilization as the ICAAS, was 48.7%. Results further showed that the immobilized cells retained their PCP-degrading ability when they were fed with the inducer (PCP) once every 20 days.  相似文献   

2.
Huang JS  Chou HH  Chen CM  Chiang CM 《Chemosphere》2007,68(2):382-388
A laboratory study using a combined upflow anaerobic sludge bed (UASB)-activated sludge (AS) reactor system was undertaken to explore the effect of recycle-to-influent ratio (R(e)=1, 2, and 3) on the activities of nitrifiers and denitrifiers. Suspended-solids pre-settled piggery wastewater was used as the substrate-feed wastewater. At the R(e) of 1-3, the combined reactor system achieved efficient removal of COD (96-97%), TKN (100%) and total nitrogen TN (54-77%). Methanogenesis occurred with nearly-complete denitrification in the UASB reactor, whereas complete nitrification took place in the AS reactor. A higher R(e) (i.e., accompanied with a shorter solids retention time) resulted in a larger amount of high-activity denitrifiers and thereby achieved a higher TN removal efficiency. Compact granules and a high biomass concentration in the UASB reactor were observed. At the R(e) of 1-3, the maximum specific reaction rate of nitrifiers (0.45-0.49 NH(4)(+)-NmgVSS(-1)d(-1)) and the specific nitrification rates of mixed culture (0.18-0.22mg NH(4)(+)-NmgVSS(-1)d(-1)) in the AS reactor varied slightly; whereas the maximum specific reaction rate of denitrifiers (0.18-0.27mg NO(x)(-)-NmgVSS(-1)d(-1)) and the specific denitrification and COD removal rates of mixed culture (0.025-0.050mg NO(x)(-)-NmgVSS(-1)d(-1); 0.24-0.31mgCODmgVSS(-1)d(-1)) in the UASB reactor increased with increasing R(e). The primary finding of the study is that the combined UASB-AS reactor system should be operated at a higher R(e) to maintain high-activity denitrifiers to remove organic materials and nitrogen from piggery wastewater.  相似文献   

3.
Microbial activity in a combined UASB-activated sludge reactor system   总被引:1,自引:0,他引:1  
Huang JS  Wu CS  Chen CM 《Chemosphere》2005,61(7):1032-1041
A combined upflow anaerobic sludge bed-activated sludge (UASB-AS) reactor system with consistently wasting of excess biomass was used to treat suspended-solids pre-settled piggery wastewater (COD=2000 mg l(-1), total Kjeldahl nitrogen TKN=400 mg l(-1), suspended solids=250-400 mg l(-1)). Thus, the activity of nitrogen-related microbial groups in each individual bioreactor was investigated. When the granules retention time (GRT) of 20-50 d in the UASB reactor, the solids retention time (SRT) of 10-25 d in the AS reactor and the recycle-to-influent ratio (Re) of 1 were maintained, the combined system removed 95-97% of chemical oxygen demand (COD), 100% of TKN and 54-55% of total nitrogen (TN). Denitrification and methanogenesis occurred in the UASB reactor so that both biochemical processes contributed to most of the COD removal and, complete nitrification (most of the TKN removal) occurred in the AS reactor. Compact granules with good settling abilities developed in the UASB reactor, and rapid rates of granulation of break-up granules in the UASB reactor were confirmed by experiments. The activity of nitrifiers and denitrifiers (an=0.68-0.87; adn=0.55-0.70) and the calculated specific nitrification and denitrification rates (qn=0.26-0.47 mg NH4+ -N mg VSS(-1)d(-1); qdn=0.046-0.076 mg NOx- -N mg VSS(-1)d(-1)) significantly increased with decreasing SRT and GRT, respectively. Accordingly, the combined UASB-AS reactor system should be regarded a promising alternative for the removal of organic carbon and nitrogen from piggery wastewater.  相似文献   

4.
活性污泥中功能性菌群抗盐度冲击性能研究   总被引:4,自引:1,他引:3  
利用批量实验研究了活性污泥在受到不同盐度冲击时,其硝化功能、反硝化功能以及生物除磷功能所受到的影响。实验结果表明,活性污泥中亚硝酸菌在氯化钠浓度为10 g/L的环境中,其硝化功能受到86%的的抑制作用;硝酸菌对盐度比亚硝酸菌更敏感,氯化钠浓度为5 g/L时已受到较强的抑制。氯化钠浓度达到50 g/L时,反硝化菌受到46%的抑制作用,反硝化菌对盐度的敏感性比硝化菌低得多。聚磷菌对盐度也很敏感,在氯化钠浓度为20 g/L的环境中,聚磷菌厌氧阶段释磷受到52%的抑制作用;而氯化钠浓度为5 g/L时,好氧阶段吸磷已受到41%的抑制作用。  相似文献   

5.
The purpose of this research was to study the fate and toxicity of triclosan (TCS) in activated sludge systems and to investigate the role of biodegradation and sorption on its removal. Two continuous-flow activated sludge systems were used; one system was used as a control, while the other received TCS concentrations equal to 0.5 and 2mgl(-1). At the end of the experiment, 1mgl(-1) TCS was added in the control system to investigate TCS behaviour and effects on non-acclimatized biomass. For all concentrations tested, more than 90% of the added TCS was removed during the activated sludge process. Determination of TCS in the dissolved and particulate phase and calculation of its mass flux revealed that TCS was mainly biodegraded. Activated sludge ability to biodegrade TCS depended on biomass acclimatization and resulted in a mean biodegradation of 97%. Experiments with batch and continuous-flow systems revealed that TCS is rapidly sorbed on the suspended solids and afterwards, direct biodegradation of sorbed TCS is performed. Regarding TCS effects on activated sludge process, addition of 0.5mgl(-1) TCS on non-acclimatized biomass initially deteriorated ammonia removal and nitrification capacity. After acclimatization of biomass, nitrification was fully recovered and further increase of TCS to 2mgl(-1) did not affect the performance of activated sludge system. The effect of TCS on organic substrate removal was minor for concentrations up to 2mgl(-1), indicating that heterotrophic microorganisms are less sensitive to TCS than nitrifiers.  相似文献   

6.
采用A/O-CSTR工艺处理高氨氮污泥脱水液。进水氨氮浓度浓度约为375 mg/L,C/N比小于1.0,反硝化碳源明显不足。A/O反应器完成短程硝化反应,CSTR定期投加初沉污泥作为碳源进行反硝化。两者联合达到总氮去除的目的。实验研究短程硝化反应的启动过程,以及CSTR出水回流对短程硝化和系统脱氮效果的影响。实验结果表明系统具有良好的硝化反硝化效果。A/O反应器亚硝酸盐积累率迅速提高并稳定在90%以上。CSTR有效利用初沉污泥实现了稳定的反硝化。出水回流有利于提高总氮去除率,在回流比为200%时,系统平均总氮去除率达到85%以上。  相似文献   

7.
污水生物脱氮硝化阶段是温室气体一氧化二氮(N2O)的重要释放源。采用连续流反应器在2种进水氨氮(NH4-N,低氮反应器60 mg/L和高氮反应器180 mg/L)浓度条件下驯化硝化菌,并研究了不同初始NH4-N浓度和不同初始亚硝酸盐(NO2-N)浓度条件下所驯化硝化菌释放N2O的特征。结果表明在反应器运行过程中2个反应器释放N2O较少,均小于去除NH4-N浓度的0.01%;N2O的释放均随着初始NH4-N浓度或初始NO2-N浓度的升高而增加;不同初始NH4-N浓度条件下,低氮反应器驯化硝化菌的N2O释放率在0.51%~1.40%之间,高氮反应器驯化硝化菌在0.29%~1.27%之间;不同初始NO2-N浓度条件下,低氮反应器驯化硝化菌的N2O释放率在1.38%~3.78%之间,高氮反应器驯化硝化菌在1.16-5.81%之间。  相似文献   

8.
A combined anaerobic/aerobic sludge digestion system was studied to determine the effect of aerobic solids retention time (SRT) on its solids and nitrogen removal efficiencies. After the anaerobic digester reached steady state, effluent from the anaerobic digester was fed to aerobic digesters that were operated at 2- to 5-day SRTs. The anaerobic system was fed with a mixture of primary and secondary sludge from a local municipal wastewater treatment plant. Both systems were fed once per a day. The aerobic reactor was continuously aerated with ambient air, maintaining dissolved oxygen level at 1.1 +/- 0.3 mg/L. At a 4-day or longer SRT, more than 11% additional volatile solids and 90% or greater ammonia were removed in the aerobic digester, while 32.8 mg-N/L or more nitrite/nitrate also was measured. Most total Kjeldahl nitrogen removal was via ammonia removal, while little organic nitrogen was removed in the aerobic digester.  相似文献   

9.
以实际生活污水为处理对象,考察了传统进水/曝气和改良型分段进水的交替缺氧-好氧(A/O)2种运行模式对CAST工艺的快速启动及脱氮除磷性能稳定维持的影响。结果表明,传统进水/曝气运行模式下,系统达到最佳营养物去除性能所需启动时间30 d,稳定运行阶段TN平均去除80.66%,磷的去除率维持在66.30%左右;采用改良型交替运行模式,反应器达到稳定运行状态仅需18 d,系统稳定运行时TN平均去除81.36%,磷去除率稳定维持在90%以上,出水磷浓度在0.3 mg/L以下,出水水质达到国家污水综合排放标准一级A(GB8978-2002)。研究还发现,传统运行模式下,由低温引起的污泥沉降性能变差导致系统污泥严重流失,反应器几乎丧失污染物去除性能;而低温对交替运行模式下的反应器除磷性能几乎没有影响,总氮去除则因氨氮不完全硝化而大大降低。  相似文献   

10.
Distribution coefficients (K(d)) between water and activated sludge particles (f(oc)=27.7+/-0.1%) were measured for the steroid estrogens (SE), estrone (E1), 17beta-estradiol (E2) and 17alpha-ethinylestradiol (EE2) in batch experiments. Experimental concentration levels ranged from environmentally realistic low ng/l to the high microg/l. In this range K(d)s were independent of their water concentration. The experimentally obtained K(d)s (with 95% confidence intervals) were 402+/-126 l/kg, 476+/-192 l/kg and 584+/-136 l/kg for E1, E2 and EE2, respectively. K(d)s were used to estimate the fraction of the total SE concentration that is expected to be sorbed in the activated sludge treatment tanks of a typical STP assuming equilibrium conditions. Assuming a suspended solids concentration of 4 g/l dissolved solids (ds), it was estimated that 61+/-9%, 66+/-13% and 70+/-6% of the total concentration of E1, E2 and EE2, respectively, would be sorbed during activated sludge treatment. The fraction of the SEs that was expected to be sorbed to suspended sludge particles in the effluents from a typical Danish STP was estimated to be only 0.20+/-0.06%, 0.24+/-0.10% and 0.29+/-0.07% of the total concentration of E1, E2 and EE2, respectively, at a suspended solids concentration of 5 mg/lds. For a typical STP the removal of steroid estrogens with excess sludge was estimated to be only 1.5-1.8% of the total loading if equilibrium conditions exists. Sorption is therefore not important for the fate of SEs in STPs compared to biodegradation.  相似文献   

11.
在2个相同的SBR中分别驯化普通污泥和耐盐污泥,研究两者在0%、0.9%、1.2%、1.5%和1.8%(W/V)的盐度(NaCl)下对生活污水脱氮性能的差异。SBR运行经过厌氧、好氧、缺氧3个阶段,HRT分别为1、6和1 h。研究结果表明:在每一级盐度下,耐盐污泥的脱氮性能都好于普通污泥。随着盐度的增大,耐盐污泥中氨氮...  相似文献   

12.
This paper describes results from a pilot study of a novel wastewater treatment technology, which incorporates nutrient removal and solids separation to a single step. The pseudoliquified activated sludge process pilot system was tested on grit removal effluent at flowrates of 29.4 to 54.7 m3/d, three different solid residence times (SRT) (15, 37, and 57 days), and over a temperature range of 12 to 28 degrees C. Despite wide fluctuations in the influent characteristics, the system performed reliably and consistently with respect to organics and total suspended solids (TSS) removals, achieving biochemical oxygen demand (BOD) and TSS reductions of > 96% and approximately 90%, respectively, with BOD5 and TSS concentrations as low as 3 mg/L. Although the system achieved average effluent ammonia concentrations of 2.7 to 3.2 mg/L, nitrification efficiency appeared to be hampered at low temperatures (< 15 degrees C). The system achieved tertiary effluent quality with denitrification efficiencies of 90 and 91% total nitrogen removal efficiency at a total hydraulic retention time of 4.8 hours and an SRT of 12 to 17 days. With ferric chloride addition, effluent phosphorous concentrations of 0.5 to 0.8 mg/L were achieved. Furthermore, because of operation at high biomass concentrations and relatively long biological SRTs, sludge yields were over 50% below typical values for activated sludge plants. The process was modeled using activated sludge model No. 2, as a two-stage system comprised an aerobic activated sludge system followed by an anoxic system. Model predictions for soluble BOD, ammonia, nitrates, and orthophosphates agreed well with experimental data.  相似文献   

13.
Heidler J  Halden RU 《Chemosphere》2007,66(2):362-369
The antimicrobial agent triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol; TCS) is a member of a larger group of polychlorinated binuclear aromatic compounds frequently associated with adverse environmental and human health effects. Whereas the structure and function of TCS would suggest significant resistance to biotransformation, biological wastewater treatment currently is considered the principal destructive mechanism limiting dispersal of and environmental contamination with this compound. We explored the persistence of TCS in a typical full-scale activated sludge US sewage treatment plant using a mass balance approach in conjunction with isotope dilution liquid chromatography electrospray ionization mass spectrometry (ID-LC-ESI-MS) for accurate quantification. Average influent and effluent concentrations (mean +/- SD) of 4.7+/-1.6 and 0.07+/-0.06 microg 1(-1), respectively, revealed an apparent (liquid-phase) removal efficiency of 98+/-1%. However, further analyses demonstrated that the particle-active TCS (80+/-22% particle-associated in influent) was sequestered into wastewater residuals and accumulated in dewatered, digested sludge to concentrations of 30000+/-11000 microg kg-1. Overall, 50+/-19% (1640+/-610 g d-1) of the disinfectant mass entering the plant (3240+/-1860 g d-1) remained detectable in sludge, and less than half of the total mass (48+/-19%) was biotransformed or lost to other mechanisms. Thus, conventional sewage treatment was demonstrated to be much less effective in destroying the antimicrobial than the aqueous-phase removal efficiency of the plant would make believe. Furthermore, study findings indicate that the common practice of sludge recycling in agriculture results in the transfer of substantial quantities of TCS to US soils used, in part, for animal husbandry and crop production.  相似文献   

14.
The properties of sludges from a pilot-scale submerged membrane bioreactor (SMBR) and two bench-scale complete-mix, activated sludge (CMAS) reactors treating municipal primary effluent were determined. Compared with the CMAS sludges, the SMBR sludge contained a higher amount of soluble microbial products (SMP) and colloidal material attributed to the use of a membrane for solid-liquid separation; a higher amount nocardioform bacteria, resulting from efficient foam trapping; and a lower amount of extracellular polymeric substances (EPS), possibly because there was no selective pressure for the sludge to settle. High aeration rates in both the CMAS and SMBR reactors produced sludges with higher numbers of smaller particles. Normalized capillary suction time values for the SMBR sludge were lower than for the CMAS sludges, possibly because of its lower EPS content.  相似文献   

15.
Vaiopoulou E  Aivasidis A 《Chemosphere》2008,72(7):1062-1068
A pilot-scale prototype activated sludge system is presented, which combines both, the idea of University of Cape Town (UCT) concept and the step denitrification cascade for removal of carbon, nitrogen and phosphorus. The experimental set-up consists of an anaerobic selector and stepwise feeding in subsequent three identical pairs of anoxic and oxic tanks. Raw wastewater with influent flow rates ranging between 48 and 168 l d(-1) was fed to the unit at hydraulic residence times (HRTs) of 5-18 h and was distributed at percentages of 60/25/15%, 40/30/30% and 25/40/35% to the anaerobic selector, 2nd and 3rd anoxic tanks, respectively (influent flow distribution before the anaerobic selector). The results for the entire experimental period showed high removal efficiencies of organic matter of 89% as total chemical oxygen demand removal and 95% removal for biochemical oxygen demand, 90% removal of total Kjeldahl nitrogen and total nitrogen removal through denitrification of 73%, mean phosphorus removal of 67%, as well as excellent settleability. The highest removal efficiency and the optimum performance were recorded at an HRT of about 9h and influent flow rate of 96 l d(-1), in which 60% is distributed to the anaerobic selector, 25% to the second anoxic tank and 15% to the last anoxic tank. Consequently, the plant configuration enhanced removal efficiency, optimized performance, saved energy, formed good settling sludge and provided operational assurance.  相似文献   

16.
Non-optimal pH, dissolved oxygen concentration, the presence of toxic substances, or the influence of grazers are known to cause disturbances in nitrification. Because activated sludge is a mixture of different organisms, bacteria, and higher organisms, the stability of processes such as carbon removal, nitrification, denitrification, and dephosphatation depends on a range of interactions. These interactions occur both between and within trophic levels. Understanding of the ecology of microorganisms involved in bioprocesses is essential for effective control of startup and operation of a particular process. The aim of the study was to gain further insight into the dynamics of nitrifiers in activated sludge at various sludge ages while treating higher concentrations of ammonium. The results confirmed the importance of Nitrosococcus mobilis and Nitrobacter sp. as the dominant nitrifiers responsible for nitritation and nitratation, respectively, in the presence of unlimited ammonium. The size of the dominant bacteria colony was larger compared to the other species present and reached 25 microm. Problems with nitrification occurred in all high-ammonium loaded reactors. The dynamics of nitrifier population was monitored by oxygen uptake rate (OUR) using a test enabling the OUR measurement separately for ammonium-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB). The results reveal the hypersensitivity of nitrifiers to the substrate and products of incomplete nitrification.  相似文献   

17.
Maximum nitrogen removal in the step-feed activated sludge process.   总被引:1,自引:0,他引:1  
This paper presents a mathematical framework that can be used to determine the flow distributions for a step-feed activated sludge process that result in maximum nitrogen removal. The model indicates that nitrogen removal efficiency in a step-feed activated sludge process is highly dependent on the ultimate biochemical oxygen demand (BOD(L))-to-total Kjeldahl nitrogen (TKN) ratio of the wastewater. For typical domestic wastewater, which has a relatively high BOD(L)-to-TKN ratio, the step-feed process will outperform the Modified Ludzack-Ettinger process for nitrogen removal, when the flow to each step is optimally distributed. Using plant-specific water quality data and operating conditions from a 1-year period, nitrogen removal performance for four step-feed activated sludge plants operated by the Sanitation Districts of Los Angeles County (California) was calculated using the developed model. The calculated nitrogen removal efficiencies match well with the actual plant performance data. These results validate the model as a useful tool for predicting nitrogen removal in a step-feed activated sludge process. Other analyses revealed that improvements in nitrogen removal at existing facilities are achievable by adjusting the split of primary effluent flow to each anoxic zone several times during the day. The timing of the adjustments and the optimal flow splits can be determined from data on diurnal fluctuations in BOD(L) and TKN concentrations. An example is provided to illustrate the application of such an operating strategy and the potential enhancement of nitrogen removal.  相似文献   

18.
为了提高传统污水处理工艺的脱氮除磷效率、实现污泥资源化,本实验通过超声破解污泥获取碳源,采用耗氧呼吸速率分析上清液作为碳源的可行性,并将上清液回用于生活污水,考察其对A2O工艺长期运行的脱氮除磷效果和微生物群落结构的影响。结果表明,上清液中可降解有机物达到76.2%,具有作为内碳源的潜能;上清液和生活污水按1∶15投入A2O反应器后,氮、磷的去除率分别从63.2%和53.4%提高到了82.1%和94.7%;上清液明显改变了微生物群落结构,使除磷菌Actinobacteia和反硝化聚磷菌Sphingobacterium富集。  相似文献   

19.
Activated sludge systems are widely used in wastewater treatment. Organic carbon removal and nutrient removal are important for stringent water discharge standards. Therefore, activated sludge systems are widely used to remove carbon, nitrogen and phosphorus in new wastewater treatment systems or upgrades of existing systems. The determination of system compounds and kinetic parameters for modelling of these systems are important. For this purpose, respirometric measurements are used to reveal the electron consumption rate of biomass. In order to determine OUR (oxygen uptake rate) and NUR (nitrate uptake rate) parameters, a laboratory scale activated sludge system, including anaerobic, anoxic and aerobic zones, was developed. The performance of the system was continuously controlled from influent and effluent samples. OUR and NUR measurements indicated the kind of nitrogen-phosphorus removal systems required. Moreover, phosphorus uptake in the anoxic zone was investigated. It was found that phosphorus uptake in the anaerobic zone was related to substrate type consumed biologically. The OUR and NUR were found to be lower than in continuous activated sludge measurements. This may be because the mixed culture of the system affected the system performance, owing to competition between denitrification bacteria and poly-P bacteria.  相似文献   

20.
考察冬季低温下沸石联合生物吸附再生工艺和改进式沸石联合生物吸附再生工艺对城市污水的脱氮效率,结果表明在HRT为3.5 h下,ZCS工艺出水氨氮为11.65 mg/L,总氮高于20 mg/L.而相同条件下MZCS工艺氨氮出水为5.45 mg/L,总氮去除率比原ZCS工艺提高了11%,均值为16.8 mg/L.通过聚合酶链式技术,变性梯度凝胶电泳和电镜扫描技术发现两工艺微生物多样性、丰度高于传统活性污泥法,兼具活性污泥法和生物膜法的微生物特性.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号