首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The implementation and maintenance of an air pollution monitoring program can be expensive and time consuming, especially when the aim is for long-term monitoring over a significant area. Consequently, it is essential that sites are optimized to provide the best representative cover while minimizing costs. In the past, there has been a tendency to locate sampling stations at pollution hot-spots. While this is acceptable for determining a maximum potential exposure or identifying the extent of a risk, there are limitations to this approach when assessing the potential impact of any future abatement strategies or determining the level of exposure outside the vicinity. This paper presents an approach in which representative air quality assessments can be undertaken for an urban area using the minimum number of measurement sites. A novel methodology is described that involves site selection to capture the maximum variance in measured pollutants, while minimizing spatiotemporal autocorrelation between the selected sites. A case study is presented for Yazd, Iran. Overall, the results show that the proposed methodology can be effective and enable the long-term monitoring of air pollution to be undertaken on a cost-effective basis in urban areas. In addition, there is the potential for the methodology to be utilized for other forms of pollution (e.g., water, soil, and noise).  相似文献   

2.
An objective methodology is presented for determining the number and disposition of ambient air quality stations in a monitoring network for the primary purpose of compliance with air quality standards. The methodolgy utilizes a data base with real or simulated data from an air quality dispersion model for application with a two-step process for ascertaining the optimal monitoring network. In the first step, the air quality patterns in the data base are collapsed into a single composite pattern through a figure-of-merit (FOM) concept. The most desirable locations are ranked and identified using the resultant FOM fields. In the second step the network configuration is determined on the basis of the concept of spheres of influence (SOI) developed from cutoff values of spatial correlation coefficients between potential monitoring sites and adjacent locations. The minimum number of required stations is then determined by deletion of lower-ranked stations whose SOIs overlap. The criteria can be set to provide coverage of less than some fixed, user-provided percentage of the coverage of tha SOIs of the higher ranked stations and for some desired level of minimum detection capability of concentration fluctuations.The methodology is applied in a companion paper (McElroy et al., 1986) to the Las Vegas, Nevada, metropolitan area for the pollutant carbon monoxide.Although the research described in this article has been funded wholly or in part by the United States Environmental Protection Agency through Contract No. 68-03-2446 to Systems Applications, Inc., it has not been subjected to Agency review and therefore does not necessarily reflect the views of the Agency and no official endorsement should be inferred.  相似文献   

3.
目前 ,我国重点城市都在开展环境空气质量日报或预报工作 ,开展这一工作的基本条件之一是必须建立环境空气质量自动监测系统。由于我国目前的研制水平有限 ,空气质量自动监测系统基本上是靠引进国外技术及设备来完成的。而引进设备往往与我国的具体实际结合不够 ,尤其是在系统结构、数据采集、远程控制与诊断方面同我们的实际要求相去甚远。为此本文将围绕国内环境监测共同关注的环境空气质量自动监测系统及其设计的问题展开讨论 ,内容包括目前国内自动监测系统的现状 ;国外发展情况及趋势 ;自动监测系统结构与要求  相似文献   

4.
A new method for multi-objective optimization of air quality monitoring systems based on satellite remote sensing of the troposphere is described in this work. The technique uses atmospheric turbidity as surrogate for air pollution loading. Through inverse chemical modeling and ancillary information the respective patterns of primary gaseous and particle pollutants are inferred. The optimization algorithm uses the resulting maps of ambient air pollution as input. It focuses on the gain of information with regard to human exposure to high pollution, potential impact on cultural heritage, compliance to ambient air quality standards, monitoring key point and area source emissions, as well as on the associated cost. Application of the method in Brescia, Italy showed its significant potential for improving the cost-effectiveness of air quality monitoring networks at the urban and regional scales.  相似文献   

5.
An ambient air quality monitoring network has been establishedusing risk assessment techniques to evaluate adverse health effects from exposures to airborne contaminants. The risk assessment method was compared to traditional methods of establishing air quality monitoring networks: identifying maximumconcentration impacts or maximum total population. Results suggest that the health risk method best predicted the locationof adverse, non-carcinogenic respiratory illnesses during the evaluation period. Spearman Rank Correlation Coefficient, r s, values obtained using the risk assessment method werestatistically greater than the values obtained using theconcentration and population methods. The concentration methodwas the least accurate predictor of adverse effects.  相似文献   

6.
In this study a new methodology is suggested to approximate the impact area downwind of an air pollution source, where air quality monitoring can be carried out to capture the maximum pollutant concentration. Hourly wind speed for a given month is grouped in to different wind speed ranges and the distance of pollutant travel is approximated from the average wind speed of that wind speed range. Since change in wind direction causes the impact distance to rotate, its rotation is approximated by the SD of wind direction change. Using this approach, area or region down wind of a source is determined and plotted. The pattern of monthly change of wind is better represented by the new type of diagram as compared to the wind rose diagram.  相似文献   

7.
An objective methodology presented in a companion paper (Liu et al., 1986) for determining the optimum number and disposition of ambient air quality stations in a monitoring network for carbon monoxide is applied to the Las Vegas, Nevada, area. The methodology utilizes an air quality simulation model to produce temporally-varying air quality patterns for each of a limited number of meteorological scenarios representative of the region of interest. These air quality patterns in turn serve as the data base in a two-step procedure for the identification and ranking of the most desirable monitoring locations (step 1) and the removal of redundancies in spatial coverage among the desired locations (step 2.)The performance of the air quality simulation model, a key element in the design methodology, was evaluated in the Las Vegas area in a special field measurement program. In the Las Vegas demonstration for carbon monoxide, 19 stations covering concentration maxima and 3 stations covering background concentrations in rural areas were identified and ranked. A 10-station network, for example, consisting of 7 stations for peak average concentrations and 3 stations for background concentrations, was selected for a desired minimum detection capability of 50% of concentration variations. Networks with fewer stations would be selected if smaller minimum detection capabilities of concentration variations are acceptable, and vice versa. Background stations could, of course, be deleted for networks with the sole purpose of discerning peak concentrations.Although the research described in this article has been funded wholly or in part by the United States Environmental Protection Agency through Contract No. 68-03-2446 to Systems Application, Inc., it has not been subjected to Agency review and therefore does not necessarily reflect the views of the Agency and no official endorsement should be inferred.  相似文献   

8.
In the last few years, due to the implementation of European and Italian laws, public agencies are in urgent need of objective criteria and methodologies for the correct location of air quality monitoring networks. This paper describes MoNet, a decision support system oriented to network designers, to help them in the choice of the number and the location of instruments in an assigned area. The package includes a model base consisting of a set of pollution diffusion simulation models and two optimization algorithms for network location and allows the user to integrate his or her own subjective knowledge of the problem with the results of the simulations performed by means of objective techniques. The package has been applied to revise the air quality network located in an industrial and urban area of Northern Italy. The results of the simulations performed by using different diffusion models, location algorithms and problem constraints are shown and discussed in the concluding section.  相似文献   

9.
Increasing human impact on stream ecosystems has resulted in a growing need for tools helping managers to develop conservations strategies, and environmental monitoring is crucial for this development. This paper describes the development of models predicting the presence of fish assemblages in lowland streams using solely cost-effective GIS-derived land use variables. Three hundred thirty-five stream sites were separated into two groups based on size. Within each group, fish abundance data and cluster analysis were used to determine the composition of fish assemblages. The occurrence of assemblages was predicted using a dataset containing land use variables at three spatial scales (50 m riparian corridor, 500 m riparian corridor and the entire catchment) supplemented by a dataset on in-stream variables. The overall classification success varied between 66.1–81.1% and was only marginally better when using in-stream variables than when applying only GIS variables. Also, the prediction power of a model combining GIS and in-stream variables was only slightly better than prediction based solely on GIS variables. The possibility of obtaining precise predictions without using costly in-stream variables offers great potential in the design of monitoring programmes as the distribution of monitoring sites along a gradient in ecological quality can be done at a low cost.  相似文献   

10.
Optimal redesign of groundwater quality monitoring networks: a case study   总被引:2,自引:0,他引:2  
Assessment and redesign of water quality monitoring networks is an important task in water quality management. This paper presents a new methodology for optimal redesign of groundwater quality monitoring networks. The measure of transinformation in discrete entropy theory and the transinformation–distance (T–D) curves are used to quantify the efficiency of sampling locations and sampling frequencies in a monitoring network. The existing uncertainties in the T–D curves are taken in to account using the fuzzy set theory. The C-means clustering method is also used to classify the study area to some homogenous zones. The fuzzy T–D curve of the zones is then used in a multi-objective hybrid genetic algorithm-based optimization model. The proposed methodology is utilized for optimal redesign of monitoring network of the Tehran aquifer in the Tehran metropolitan area, Iran.  相似文献   

11.
在全省城市环境空气质量监测网优化并运行六年的基础上 ,采用历史数据计算法对河南省环境空气质量监测网进行了优化。通过优化方法和监测项目的探索 ,确定了省控站数目 ,特别是提出了系统、完整的优化指标 ,优化结果是令人满意的。  相似文献   

12.
This paper presents an integrated exposure monitoring system, based on an expansion of existing air quality monitoring systems using dispersion modelling. The system allows: (1) identifying geographical areas whose inhabitants are most exposed to ambient pollution; (2) identifying how many people in an area are exposed to concentrations of pollution exceeding air quality guidelines; (3) describing the exposure of population subgroups (e.g. children); (4) planning pollution abatement measures and quantifying their effects; (5) establishing risk assessment and management programs, and (6) investigating the short- and long-term effects of both pollutants and pollution sources on public health. The effect of pollution is rarely very large and in order to discover it, exposure estimation must provide data that reflects both spatial and temporal variations. Estimates of pollution exposure are obtained using an integrated approach that combines results of measurements from monitoring programs with dispersion calculations. These values can serve as estimates for individual short-term or long-term exposure. The grouped data allows the expression of ambient pollution concentrations as the spatial distribution of estimates such as the mean or 98th percentile of such compounds as SO2, O3, NO2, PM10 and PM2.5. This integrated approach has been combined into a single software package, AirQUIS.  相似文献   

13.
系统比较了DOAS大气监测系统与传统点式采样设备在测定环境空气中二氧化硫的性能。  相似文献   

14.
A review is given of methods being used to identify and interpret trends in air quality data from single stations and from networks of stations. Some comments are also included concerning the problem of designing networks which will identify trends as quickly as possible, thus providing early warnings of significant changes in air quality.Reprinted from the Preprint Volume, WMO Technical Conference on Regional and Global Observation of Atmospheric Pollution Relative to Climate, Boulder, Col., Aug. 1979, WMO Geneva, No. 549.  相似文献   

15.
Over the past decade, an increased tendency to consume meals at dining facilities outside the home has been highlighted; moreover, meals supplied in food businesses have been involved in many foodborne disease outbreaks. Therefore, microbial air contamination in food processing facilities could be a concern and an increase of microbial loads could represent a risk factor, especially for the potential contamination of foods due to undesirable spoiling and pathogenic bacteria. In this paper, the results of an 11-year microbiological monitoring of air quality in a university canteen are reported. The study, which started in the year 2000, was performed within a hazard analysis and critical control point (HACCP) plan implementation of a canteen that produces about 1,000 meals a day in order to verify the effectiveness of corrective actions on the indoor air quality. The primary food preparation room, the kitchen, and three cold rooms underwent air sampling by using a calibrated impaction sampler. Our investigation detected a general and progressive improvement in the air quality of the canteen since the beginning of the study, thus suggesting the appropriateness of the corrective action undertaken during the HACCP implementation program.  相似文献   

16.
17.
Airborne particulates have a major influence on the quality of indoor environments, which in turn affects human health. Both allergens and proteases are major etiological factors in allergic disease. Thus, the monitoring of environmental protease particulates is very important for the management of allergic disease. Protease-monitoring systems have been introduced in industry, but have not been applied to domestic settings, probably because of the high cost and many complex steps involved in these systems. In this study, we developed an indoor protease-monitoring system which can easily detect protease particulates without need for pre-treatment of dust samples or complex measuring instruments such as fluorescent plate reader. As a protease substrate, gelatin thin film (GTF) was adopted to evaluate small amounts of house dust particulates. The principle of this assay is based on the hydrolysis of GTF. Protease molecules spread from a particulate to GTF can hydrolyze the gelatin, thereby producing a spot on the GTF. This hydrolyzed spot visualized by staining was much larger than the particulate size, making visible to naked eye. The GTF method facilitated the observation of a subtle increase in protease particulates fallen on the GTF after the turnover of a used bed-quilt. The newly developed GTF method seems to be a suitable tool for protease monitoring at home.  相似文献   

18.
介绍地表水水质自动监测站提水系统的设计方案 ,分析各方案的优缺点 ,探讨各方案的适应性及选择最佳方案 ,以期对自动站的建设提供参考。  相似文献   

19.
The Loxahatchee National Wildlife Refuge (Refuge) is affected by inflows containing elevated contaminant concentrations originating from agricultural and urban areas. Water quality was determined using three networks: the Northern Refuge (NRN), the Southern Refuge (SRN), and the Consent Decree (CDN) monitoring networks. Within these networks, the Refuge was divided into four zones: (1) the canal zone surrounding the marsh, (2) the perimeter zone (0 to 2.5 km into the marsh), (3) the transition zone (2.5 to 4.5 km into the marsh), and (4) the interior zone (>4.5 km into the marsh). In the NRN, alkalinity (ALK) and conductivity (SpC) and dissolved organic carbon, total organic carbon, total dissolved solids (TDS), Ca, Cl, Si, and SO4 concentrations were greater in the perimeter zone than in the transition or interior zone. ALK, SpC, and SO4 concentrations were greater in the transition than in the interior zone. ALK, SpC, and TDS values, Ca, SO4, and Cl had negative curvilinear relationships with distance from the canal toward the Refuge interior (r 2?=?0.78, 0.67, 0.61, 0.77, 0.62, and 0.57, respectively). ALK, TB and SpC, and Ca and SO4 concentrations decreased in the canal and perimeter zones from 2005 to 2009. Important water quality assessments using the SRN and CDN cannot be made due to the sparseness and location of sampling sites in these networks. The number and placement monitoring sites in the Refuge requires optimization based on flow pattern, distance from contaminant source, and water volume to determine the effect of canal water intrusion on water quality.  相似文献   

20.
An attempt was made to explain ambient air quality violations in the vicinity of industrial plants. Micrometeorology, diffusion calculaations, ambient readings, and plant engineering data are all taken into consideration to ascertain whether the plant is or is not the principal offender.Scrutiny of hi-vol filters using scanning electron microscopy for particle size analysis and particle chemical make-up as an assessment technique is also described.Case histories using the above analytical techniques are discussed.Presented at the 16th National Conference on Energy and the Environment, May 23, 1979  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏