共查询到20条相似文献,搜索用时 93 毫秒
1.
通过12个月采集的153个水样,调查了中国南方城市佛山某水厂城乡集中供水管网中消毒副产物(DBPs)的浓度水平与时空分布情况.在供水管网中,三卤甲烷(THMs)、卤乙醛(HALs)、卤乙腈(HANs)和卤乙酰胺(HAcAms)这4类DBPs均被检出,其中位浓度分别为19.81、2.91、1.70和1.14μg·L-1.4类DBPs浓度在输送至农村方向管网水中的沿程变化规律与在输送至城市方向的相似.供水干管中的THMs、HALs和HANs浓度均随输配距离的增加而增大,且支管中DBPs浓度普遍更高.管网水中的4类DBPs浓度在冬季均相对较低,而THMs、HALs、HANs浓度在春季相对较高.该调查结果补充了对中国南方城乡集中供水的长距离管网输送中DBPs浓度水平与变化规律的认识,为城乡集中供水地区水质安全评价与风险控制提供依据. 相似文献
2.
消毒副产物(disinfection by-products, DBPs)是影响饮用水水质的重要指标.以浙江省H市某区域供水点为调查目标,考察终端龙头水及加热器处理后饮用水中DBPs的含量特征,结合水质理化指标,初步确定管网终端DBPs预测模型,评估经口摄入的健康风险.结果表明,H市某供水点龙头水中共检出THMs、HANs和HAAs这3类共计10种DBPs.龙头水中目标DBPs检出率均为100%,THMs、HANs和HAAs质量浓度分别为10.12~28.39、 0.98~5.19和2.65~7.83μg·L~(-1);热水中TBM、TCAN和DBAN的检出率分别为46.43%、 82.14%和92.86%,BCAN未检出,其它DBPs检出率为100%,THMs、HANs和HAAs质量浓度分别为0.60~12.58、 0.02~0.52和2.42~5.86μg·L~(-1).加热处理后THMs和HANs的含量有所降低,总量分别降低84.22%和91.45%,HAAs变化不明显.水质理化指标pH值和SUVA与DBPs呈正相关关系,余氯和氨氮与DBPs呈负相关关系.根据常规指标与DBPs相关性建立THMs多元线性预测模型,相对误差小于10.00%,准确度较高,可用于管网供水终端THMs的预测.基于美国环保署推荐的健康风险评价模型对经口摄取途径时氯消毒副产物的致癌和非致癌风险进行计算,发现H市龙头水和热水中DBPs通过饮水途径的致癌风险分别为(17.24~84.63)×10~(-6)和(25.49~258.82)×10~(-7);非致癌风险分别为(4.17~50.32)×10~(-2)和(6.52~107.74)×10~(-3).龙头水中BDCM对致癌风险的贡献率最大,而热水系统中TCM贡献率最大;龙头水及热水中非致癌风险主要来自于TCM.热水中THMs的削减量最高达到94.38%,致癌风险降低79.00%. 相似文献
3.
供水管网主要是将水从水厂输送到用户的输送纽带,然而在输送水的过程当中,也应当做好一定的措施来维护水质,因为通过供水管输送到用户的供水过程当中,水质很容易出现污染的情况,污染情况严重时,将直接影响人民群众的生命财产安全。本文针对供水管网水质污染原因进行分析,并推出相关防控措施以供参考。 相似文献
4.
本文主要阐述了管网中管垢的形成原因及影响。确定了管垢是影响管网水质和输水能力的重要因素。针对控制管垢的形成采取相应的防治措施。 相似文献
5.
当贵阳市自来水厂水水质Fe,Mn超饮用水标准时,其供水系统会出现黄黑水,Fe,Mn虽未超标,由于供水系统网因加氯出现的酸侵蚀和氧化还原反应,Fe,Mn沉积管壁,当沉积量较大和水力条件变化时也会出现黄,黑水,除上述成因外,水源水质稳定性的计算表明,进入管网的水源水质不稳定,同样也会出现黄,黑水,同时在研究的基础上提出了黄,黑水的防治技术。 相似文献
6.
以大肠杆菌为受试菌种,研究了紫外线光强、配水水质及微生物因素对紫外线消毒的影响.在所选取的紫外光强范围内(0.044~0.163mW/cm2),光强对紫外线灭活大肠杆菌的去除率影响不大.水质(浊度、铁和腐殖酸等)对水样的吸光度及紫外线穿透率都有明显的影响;但是对大肠杆菌的灭活率影响不显著;当紫外线剂量增加时,这种影响逐渐变小到可以忽略.微生物的初始浓度对紫外线对微生物的灭活率有影响,微生物初始浓度越大,灭活率越高;对于不同初始浓度,紫外线灭活后存活的微生物数量比较接近. 相似文献
7.
8.
针对游离态蓝藻胞外聚合物(EPS)在常规水处理工艺中不易去除、残留蓝藻EPS极易进入供水管网的特性,研究了蓝藻EPS对供水管网水质变化及生物稳定性的影响.针对管道使用时限分析了不同管道内部产生附膜条件下,蓝藻EPS对供水管网中余氯、浑浊度、生物稳定性、有机组分等主要水质指标变化规律的影响.结果表明,蓝藻EPS加快了管网余氯衰减速度,导致管网水质浑浊度在12~24h后即超出生活饮用水卫生标准上限,并使管网水质生物稳定性降低,BDOC在72h内增加37.2~39.5%,AOC增加365~393%,总活菌数升高18~20倍.阐明了蓝藻水华爆发时期净水厂出厂水残留蓝藻EPS在管网余氯存在前提下,仍然能够作为微生物营养基质和代谢能量,而促进管道内细菌生长繁殖,增加微生物代谢活性,刺激微生物胞外有机组分分泌释放,导致管网水质二次污染. 相似文献
9.
针对游离态蓝藻胞外聚合物(EPS)在常规水处理工艺中不易去除、残留蓝藻EPS极易进入供水管网的特性,研究了蓝藻EPS对供水管网水质变化及生物稳定性的影响.针对管道使用时限分析了不同管道内部产生附膜条件下,蓝藻EPS对供水管网中余氯、浑浊度、生物稳定性、有机组分等主要水质指标变化规律的影响.结果表明,蓝藻EPS加快了管网余氯衰减速度,导致管网水质浑浊度在12~24h后即超出生活饮用水卫生标准上限,并使管网水质生物稳定性降低,BDOC在72h内增加37.2~39.5%,AOC增加365~393%,总活菌数升高18~20倍.阐明了蓝藻水华爆发时期净水厂出厂水残留蓝藻EPS在管网余氯存在前提下,仍然能够作为微生物营养基质和代谢能量,而促进管道内细菌生长繁殖,增加微生物代谢活性,刺激微生物胞外有机组分分泌释放,导致管网水质二次污染. 相似文献
10.
再生水紫外线-氯联合消毒工艺特性研究 总被引:2,自引:0,他引:2
以二级出水作为消毒对象,比较了紫外线-氯联合消毒与单一紫外线消毒对水中肠道指示菌的灭活效果,考察了联合消毒工艺副产物(三卤甲烷)生成情况.结果表明,单一紫外线消毒对肠道指示菌的灭活曲线在剂量大于10mJ/cm2时存在拖尾现象,剂量为80mJ/cm2时对总大肠菌群最高对数灭活率约为2.5;而在紫外线剂量20mJ/cm2、氯投加量8mg/L(接触时间30min)条件下,紫外线-氯联合消毒对总大肠菌群的对数灭活率达到7.0.20mJ/cm2紫外线与8mg/L氯消毒组合及80mJ/cm2紫外线与3mg/L氯消毒组合均可有效灭活总大肠菌群浓度至3CFU/L以下.经紫外线照射后再氯消毒,二级出水中三卤甲烷生成量仅为10~55mg/L.80mJ/cm2紫外线照射再氯消毒后三卤甲烷生成量略高于20mJ/cm2紫外线照射再氯消毒的情形.紫外线消毒后投加氯消毒,可有效提高再生水消毒效果,控制消毒副产物生成量. 相似文献
11.
WANG Jian-ling WANG Bao-zhen WANG Lin ZHANG Jin-song HUANG Wen-zhang 《环境科学学报(英文版)》2006,18(4):634-638
The concentration of suspended solids of effluent often varies in a wide range, therefore the dose of ultraviolet light (UV) in disinfection process needs to be adjusted to meet the disinfection criterion at a high frequency, and the desired disinfection effect is difficult to be ensured. The particles size and particle-associated fecal coliform (F.C.) contribution, and their influence on UV disinfection were investigated when ClO2 and UV combined disinfection process was used. The results showed that suspended solids content had a major impact on UV disinfection efficiency, especially the large particle size fraction. Particles (D〉10μm) associated F. C. were difficult to be disinfected and were the main part of the railings of F.C. inactivation curve. Pre-ClO2 oxidation could reduce the number of particles in effluent, and make large particles decrease to small ones. Therefore, the influence of particles on UV disinfection could be reduced after pre-ClO2 oxidation, and the resistance ability to particle loadings of combined process was enhanced. Moreover, the combined process has a lot of advantages, such as low toxicity, low operational/maintenance costs; it is also convenient to be established in the existing wastewater plant or the new planned one. 相似文献
12.
应用以MPSS模型为基础的计算软件UV calc对某饮用水紫外线消毒反应器进行强度分布的计算,同时,采用枯草芽孢杆菌(ATCC9372)作为受试菌种进行生物验证.结果显示,在该反应器中理论计算数值总体上明显高于生物验证的数值,反应器中最低紫外剂量区域出现在2支灯管之间的反应器壁附近.另外,理论计算和生物验证的误差与流量、透光率具有相关性.在高流量、低透光率的情况下,理论计算的数值更接近于生物验证数值.相对于理论计算,生物验证是确定紫外线反应器剂量反应曲线的可靠方法. 相似文献
13.
14.
Several disinfection processes of ultraviolet (UV), chlorine or UV followed by chlorine were investigated in municipal wastewater according to the inactivation of Escherichia coli, Shigella dysenteriae and toxicity formation. The UV inactivation of the tested pathogenic bacteria was not affected by the quality of water. It was found that the inactivated bacteria were obviously reactivated after one day in dark. Fluorescent light irradiation increased the bacteria repair. The increase of UV dosage could cause more damage to bacteria to inhibit bacteria self-repair. No photoreactivation was detected when the UV dose was up to 80 mJ/cm2 for E. coli DH5αup, and 23 mJ/cm2 for S. dysenteriae. Nevertheless, sequential use of 8 mJ/cm2 of UV and low concentration of chlorine (1.5 mg/L) could effectively inhibit the photoreactivation and inactivate E. coli below the detection limits within seven days. Compared to chlorination alone, the sequential disinfection decreased the genotoxicity of treated wastewater, especially for the sample with high NH3-N concentration. 相似文献
15.
以体外培养的中国仓鼠肺成纤维细胞V79为模型,用分光光度法和ESR自旋标记方法研究了吸烟烟气对细胞的损伤以及抗氧化剂茶多酚(GTP)的保护作用。结果表明,吸烟烟气能引发V79细胞膜的脂质过氧化,导致细胞死亡,使膜浅层的流动性增加,但对膜深层的动态性质没有明显改变。加入GTP后能抑制烟气引起的膜脂过氧化和膜流动性的改变以及细胞死亡,且这种抑制作用与GTP的浓度呈量效关系,而GTP本身对细胞膜浅层的流动性无明显作用,但对深层的流动性则有一定的影响。此外,还用马来酰亚胺自旋探针研究吸烟烟气对细胞膜膜蛋白巯基结合位点局部构象的影响,结果发现,随着烟气作用增强,ESR波谱的强弱固定化比值(S/W)增大,表明膜蛋白上巯基结合位点处结构变得紧密,这说明吸烟烟气改变了膜蛋白的构象,GTP本身在高浓度(>0.1mg/mL)时也能使S/W增大,当低浓度(<0.05mg/mL)则没有影响。当GTP浓度为0.01mg/mL时就可以抑制烟气引起的S/W的增大。 相似文献
16.
从某污水处理厂二级出水分离出粪肠球菌、短芽孢杆菌、假单胞杆菌和大肠杆菌4种耐药菌,通过菌落计数法、qPCR评价UV、O3及UV/O3对耐药菌和抗性基因的削减效果.研究表明,3种方式对耐药菌均有较好的削减效果,其中革兰氏阳性菌灭活效果比阴性菌差;对抗性基因的削减受消毒方式和抗性基因的种类影响较大,结果表明短芽孢杆菌在耐药菌和抗性基因削减过程中表现出较强的抗逆性.结合复活实验和扫描电镜发现,UV消毒72h后耐药菌的光复活率为6.93%~11.58%;O3因破坏了细胞结构未出现光复活现象,这一过程中胞内抗性基因可能释放到环境中;UV/O3对耐药菌造成的损伤同样具有不可逆性. 相似文献
17.
供水管网覆盖区域大,导致出厂消毒剂量不足以维持管网末梢余氯量,需进行途中二次投氯.以H市供水管网为目标,通过均匀布点采样分析,考察二次加氯消毒型管网中消毒副产物(disinfection by-products,DBPs)的分布特征.结果表明,管网中检出DBPs包括三氯甲烷(TCM)、一溴二氯甲烷(BDCM)、二溴一氯甲烷(DBCM)、三溴甲烷(TBM)、二氯乙酸(DCAA)、三氯乙酸(TCAA)、二氯乙腈(DCAN)、溴氯乙腈(BCAN)和三氯硝基甲烷(TCNM)等,所检水样中DBPs浓度均低于《生活饮用水卫生标准》(GB 5749-2006)规定的标准限值.二次加氯前检出质量浓度(以平均值±偏差表示)分别为:(8.08±3.34)、(9.77±2.91)、(7.38±4.82)、(2.65±2.02)、(2.95±3.26)、(6.02±6.06)、(3.13±2.48)、(1.61±2.05)和(0.15±0.10)μg·L~(-1).二次加氯后检出质量浓度分别为:(10.30±4.55)、(11.73±3.60)、(8.23±5.22)、(2.95±2.45)、(3.29±3.60)、(8.15±7.58)、(3.31±2.61)、(1.33±2.04)和(0.12±0.06)μg·L~(-1).二次加氯后DBPs含量相较于出厂水至二次加氯点呈明显上升趋势,三卤甲烷(THMs)和卤乙酸(HAAs)分别比前段管网含量升高6.32%~26.60%和5.32%~42.71%.此外,原水水质和季节变化对DBPs的形成有一定影响,夏季DBPs的水平普遍高于春季或秋季.出厂水及管网水DBPs生成势分析表明,H市供水系统中DBPs可能存在超标风险,后续需考虑进一步优化处理工艺以保障供水水质. 相似文献
18.
考察了城市污水氯和紫外消毒过程中不同物理形态的胞外抗性基因的产生行为与及微生物群落的关联特征.结果表明,氯消毒尽管使胞内抗性基因丰度下降,但使结合型胞外抗性基因丰度明显上升(0.7±0.1)log,而游离型胞外抗性基因丰度下降(0.2±0.1)log.紫外消毒也使胞内抗性基因下降,但使游离型胞外抗性基因显著上升(0.4±0.2)log,而结合型胞外抗性基因丰度下降(0.3±0.1)log.氯消毒后,结合型胞外DNA(a-eDNA)中变形菌门丰度下降而其他菌门的丰度上升,细菌多样性指数由4.2上升到4.7;而游离型胞外DNA(f-eDNA)中变形菌门上升了6.6%,多样性指数则从3.5降低到2.8.紫外消毒后,a-eDNA中变形菌门丰度下降了36.6%,多样性则上升到4.8,而f-eDNA中细菌丰度变化较小.分子生态网络分析揭示了抗性基因与细菌间广泛的寄存关系,tetA、tetX、sulI和sulII分别与17、15、15和5种菌属间存在共现性,表明抗性基因潜在宿主的变化是导致消毒后胞外抗性基因产生的关键原因.本研究表明氯和紫外消毒不能消除抗性基因风险,反而通过导致不同胞外抗性基因的大量产生,使风险的形式发生变化. 相似文献
19.
This work investigated the formation of carbonaceous and nitrogenous disinfection by-products (C-DBPs, N-DBPs) upon chlorination of water samples collected from a surface water and a ground water treatment plant (SWTP and GWTP) where the conventional treatment processes, i.e., coagulation, sedimentation, and filtration were employed. Twenty DBPs, including four trihalomethanes, nine haloacetic acids, seven N-DBPs (dichloroacetamide, trichloroacetamide, dichloroacetonitrile, trichloroacetonitrile, bromochloroacetonitrile, dibromoacetonitrile and trichloronitromethane), and eight volatile chlorinated compounds (dichloromethane (DCM), 1,2-dichloroethane, tetrachloroethylene, chlorobenzene, 1,2-dichlorobenzene, 1,4-dichlorobenzene, 1,2,3-trichlorobenzene and 1,2,4-trichlorobenzene) were detected in the two WTPs. The concentrations of these contaminants were all below their corresponding maximum contamination levels (MCLs) regulated by the Standards for Drinking Water Quality of China (GB5749-2006) except for DCM (17.1 μg/L detected vs. 20 μg/L MCL). The SWTP had much higher concentrations of DBPs detected in the treated water as well as the DBP formation potentials tested in the filtered water than the GWTP, probably because more precursors (e.g., dissolved organic carbon, dissolved organic nitrogen) were present in the water source of the SWTP. 相似文献
20.
合流制排水系统降雨径流污染物的特性及来源 总被引:21,自引:2,他引:21
在昆明市典型合流制排水小区对降雨径流进出水水量、水质进行了研究,旨在揭示城市区域合流制排水系统中降雨径漉不同来源的污染物特性及各个污染源的比倒.分别监测了合流制排水系统日常污水以及4场降雨期间小区出口断面、街道、屋顶、庭院降雨径流的水量、水质.结果表明,人为干扰是影响城市径流污染物输出强度的主要因素,城市下垫面降雨径流污染物输出浓度顺序为:道路>庭院>屋顶,道路是城市面源污染的关键源区;道路次降雨径流量约25%,却产出了40%~80%的污染物,而屋顶次降雨径流量约50%,却仅有4%~30%的污染物负荷.合流制排水系统中管道沉积物在降雨期间的迁移是重要的污染源,4场降雨中管道沉积物的TN、TP、SS、COD和BOD5的污染贡献率在30%以上.降雨强度是影响管道沉积物输出的重要因素,在高强度降雨下,管道沉积物污染贡献率高50%以上.在不同的降雨特性条件下,合流制排水系统主导污染源有所不同. 相似文献