首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Serum PAPP-A measurements taken from 254 women in the first trimester are reported. Eleven chromosomal abnormalities were detected. The mean serum PAPP-A levels in cases of Down syndrome were 0.44 MOM at 9 weeks gestation, 0.15 MOM at 10 weeks, and 0.29 MOM at 11 weeks. The PAPP-A level at 10 weeks was below those of pregnancies which aborted spontaneously. At 11 weeks, the pregnancies with Down syndrome recorded the lowest PAPP-A levels at that gestation. On this small sample, offering chorionic villus sampling to women with singleton pregnancies and a PAPP-A level below 0.3 MOM (approximately 6.5 per cent of this at-risk group) would have detected all the Down syndrome fetuses at 10 weeks and 50 per cent at 11 weeks without selecting those cases destined to abort. This suggests that serum PAPP-A should continue to be investigated as a potential first-trimester screening test for Down syndrome.  相似文献   

2.
In a series of 54 cases of pregnancies complicated by Down syndrome and 224 unaffected pregnancies we examined maternal serum levels of hyperglycosylated human chorionic gonadotrophin (HhCG) in samples collected in the first trimester (11–13 weeks) using a sialic acid-specific lectin immunoassay. We compared these levels with those of other potential first trimester serum markers [free β-hCG, pregnancy-associated plasma protein A (PAPP-A) and total hCG (ThCG)] and modeled detection rates and false-positive rates of various biochemical markers in conjunction with fetal nuchal translucency (NT) and maternal age using an maternal age standardized population. Maternal serum HhCG in cases of Down syndrome were significantly elevated (median MoM 1.97) with 24/54 (44%) of cases above the 95th centile for unaffected pregnancies. Free β-hCG was also elevated (median MoM 2.09) with 33% of cases above the 95th centile. PAPP-A levels were reduced (median MoM 0.47) with 38% below the 5th centile. ThCG levels, whilst elevated (median MoM 1.34), had only 20% of cases above the 95th centile. Maternal serum HhCG levels were not correlated with fetal NT but showed significant correlation with ThCG and free β-hCG and with PAPP-A in the Down syndrome group (r=0.536). Maternal serum HhCG levels in cases with Down syndrome had a significant correlation with gestational age, increasing as the gestation increased. When HhCG was combined together with fetal NT, PAPP-A and maternal age, at a 5% false-positive rate the modeled detection rate was 83%, some 6% lower than when free β-hCG was used and some 4% better than when ThCG was used. Maternal serum HhCG is unlikely to be of additional value when screening for Down syndrome in the first trimester. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

3.
The aims of this study were to determine whether assumptions used in prenatal screening for Down syndrome in twin pregnancies are valid and derive estimates of risk and screening performance in twin pregnancies using observed data. Data were collected on nuchal translucency, chorionicity, pregnancy associated plasma protein-A (PAPP-A), and free ß human chorionic gonadotrophin (free ß-hCG) from 61 twin pregnancies with Down syndrome and 7302 unaffected twin pregnancies. Distribution parameters were determined and used to estimate screening performance. The assumption that proportional differences in serum marker levels in affected and unaffected singleton pregnancies apply to twin pregnancies was not confirmed. Median free β-hCG value in monochorionic affected twin pregnancies (2.63 multiples of the median [MoM]; 95% CI, 1.79-3.22 MoM) was lower than that assuming proportionality (3.76 MoM), and the median PAPP-A value in dichorionic affected twin pregnancies (1.88 MoM; 95% CI, 1.60-2.17 MoM) was higher than that based on proportionality (1.33 MoM). The detection rate was 87% for a 3% false-positive rate in monochorionic twin pregnancies and 74% in dichorionic twin pregnancies compared with 86% in singleton pregnancies. Estimates of screening performance in Down syndrome twin pregnancies do not need to rely on assumptions and can take account of chorionicity and gestational age.  相似文献   

4.
In pregnancies obtained after assisted reproduction the false-positive rate of second trimester Down syndrome (DS) screening is increased by 1.5–3-fold. This may cause an increase in the number of amniocenteses and the fetal loss rate. The present study for the first time examined whether assisted reproductive technologies affect the results of first trimester screening. The markers PAPP-A, free β-hCG and the nuchal translucency (NT) thickness were examined at 12–14 weeks' gestation. Screening markers in 47 in vitro fertilisation (IVF), 63 ovulation induction (OI) and 3026 spontaneously conceived singleton pregnancies were compared. The MoM (multiples of the median) value in the IVF pregnancies was 1.02 (95% CI: 0.85–1.22) for PAPP-A, 1.14 (95% CI: 0.95–1.37) for β-hCG and 0.97 (95% CI: 0.89–1.05) for NT; the MoM value in the OI pregnancies was 0.89 (95% CI: 0.76–1.05) for PAPP-A, 1.08 (95% CI: 0.93–1.25) for β-hCG and 1.02 (95% CI: 0.95–1.11) for NT. The first trimester marker values in assisted reproductive pregnancies and spontaneously conceived pregnancies were not significantly different. Estimated false-positive rates for a risk cut-off of 1:400 varied from 4.7% in IVF pregnancies to 5.1% in OI pregnancies. Therefore the false-positive rate in Down syndrome screening should be independent of the method of conception. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

5.
Over the past three years approximately 12 000 women have been screened in the first trimester through our OSCAR programme, which utilizes fetal NT and maternal serum free β-hCG and PAPP-A. During this time 30 cases of Down syndrome were identified either prenatally or postnatally. Using an established procedure the accuracy of predicted risk for Down syndrome was assessed in a population of 30 cases of Down syndrome and 11 758 unaffected pregnancies. The correlation between predicted risk and prevalence of Down syndrome was very high (r=0.9995). It is concluded that risks produced by the Fetal Medicine Foundation combined risk algorithm agree very closely with Down syndrome prevalence and can be used with confidence when counselling women of their risk. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
Serum measurements of pregnancy-associated plasma protein A (PAPP-A) and the free β-human chorionic gonadotrophin (hCG) subunit were made in 13 women with Down syndrome (DS) pregnancies and six other women with fetal aneuploidy ascertained at chorionic villus sampling (CVS), as well as 89 women with contemporaneous normal control pregnancies. Median serum PAPP-A measurements (0·31 MOM, 95 per cent confidence interval (CI) 0·22–0·65 vs. normal 1·06, 95 per cent CI 0·89–1·20) were lower and free β-hCG subunit measurements (1·13 MOM, 95 per cent CI 0·93–2·63 vs. normal 0·91, 95 per cent CI 0·79–1·03) were higher at statistically significant levels. Receiver operator characteristic (ROC) curves showed that the highest sensitivity for detection, 71·2 per cent (95 per cent CI 54·7–87·6 per cent), was for depressed PAPP-A levels; the combination of low serum PAPP-A levels, maternal age, and elevated free β-hCG levels yielded a detection rate of 78·9 per cent (95 per cent CI 64·9–92·8 per cent) of the affected pregnancies at 8–12 weeks' gestation.  相似文献   

7.
Published studies have shown that some serum markers used in screening for Down syndrome tend to be lower among women with insulin-dependent diabetes mellitus (IDDM). On this basis, many screening programmes adjust the marker levels to take account of this difference. Recent studies suggested that the marker levels were not different, and so adjustment may no longer be needed, possibly because of better diabetic control. Data from a prenatal screening programme for Down syndrome were examined to see whether the median values of second-trimester screening markers were still reduced in pregnant women with IDDM. A total of 366 women with IDDM singleton pregnancies without Down syndrome were identified from the screening programme at Barts from 1989 to 2002. After allowing for maternal weight, the median multiples of the median (MoM) for IDDM-unaffected singleton pregnancies were as follows: 0.88 (95% confidence interval 0.84–0.93) for alphafetoprotein (AFP), 0.95 (0.91–0.99) for unconjugated oestriol (uE3), 0.90 (0.80–1.01) for total human chorionic gonadotrophin (total hCG), 0.98 (0.88–1.08) for free β-hCG, and 0.99 (0.89–1.10) for inhibin-A. The median levels for AFP and uE3 were statistically significantly lower in pregnant women with IDDM. The other markers were not significantly different in women with and without IDDM. There remains a case for adjusting AFP and uE3 levels in women with IDDM in prenatal screening programmes for Down syndrome. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

8.
Maternal serum levels of human chorionic gonadotrophin and its subunits (intact, α, and free βhCG) and pregnancy-associated plasma protein A (PAPP-A) were measured in 279 women between 8 and 14 weeks' gestation. This group included 23 pregnancies in which the fetus had Down syndrome (DS), diagnosed either at birth or during the second trimester (n=17) or from chorionic villus sampling (CVS) (n=6). Normal medians were determined from the 258 apparently normal pregnancies. The median levels of intact hCG (1·4 MOM) and free βhCG (2·1 MOM) were significantly raised, whereas the median level of PAPP-A (0·39 MOM) was significantly lower in the DS pregnancies when compared with the control group. Levels of αhCG were similar in both the control and the DS pregnancies. Analysis of samples taken prior to 14 weeks' gestation demonstrated that only PAPP-A (0·34 MOM) was significantly altered in DS pregnancies. However, after the exclusion of DS cases diagnosed at CVS, the median intact hCG (1·56 MOM), free βhCG (2·27 MOM), and αhCG (1·8 MOM) were all raised in DS pregnancies. This emphasizes the problem of the interpretation of biochemical markers when DS cases are diagnosed at CVS.  相似文献   

9.
In a group of 149 women who had undergone routine first trimester screening using fetal nuchal translucency thickness (NT) and maternal serum free β-hCG and pregnancy associated plasma protein-A (PAPP-A) in two consecutive pregnancies the within person between pregnancy biological variability of these markers has been assessed. For fetal NT there was no correlation between NT MoM in the first and second pregnancy (r=0.0800). For maternal serum free β-hCG MoM a significant correlation was observed (r=0.4174) as was also found for PAPP-A MoM (r=0.3270). The implications for such between pregnancy marker association is that women who have an increased risk of Down syndrome in their first pregnancy are 1.5–2 times more likely to repeat this event in their next pregnancy. This observation may be useful in counselling women in the first trimester screening of a subsequent pregnancy. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

10.
The value of maternal serum pregnancy-associated plasma protein (PAPP)-A in screening for Down syndrome in early pregnancy was assessed using stored samples. Seventeen cases of Down syndrome and 66 unaffected control pregnancies were studied. The median PAPP-A level in the cases was 0.42 multiples of the expected value in controls (p <0.0001). Eleven cases (65 per cent) had levels less than half the expected value compared with only six controls (9 per cent). A commercial assay kit is now needed so that prospective screening with this marker can begin.  相似文献   

11.
The high detection rate (DR) for Down syndrome (DS) pregnancies which can be achieved by measuring fetal nuchal translucency (NT) early in pregnancy can be improved by combining it with placental hormones [pregnancy-associated plasma protein A (PAPP-A) and free β-human chorionic gonadotrophin (fβ-hCG)] and maternal age (‘combined test’). In this study we wanted to assess the DR using the ‘combined test’ in an unselected population of self-referred pregnant women at a false-positive rate (FPR) of about 5%. NT, PAPP-A, fβ-hCG and maternal age were measured in all women with singleton pregnancies who booked for delivery in our hospital from 1 December 1997 to 31 April 2000 and who were between 10 and 13 completed weeks of gestation [crown–rump length (CRL) 35–70 mm]. The specific DS risk was calculated using the computer program Alpha Version 5aa (Logical Medical Systems, London, UK). A total of 4939 women were tested. Out of 14 DS pregnancies that occurred during this period of time, 12 were detected with the test. A total of 246 women had a false-positive test result in a non-DS pregnancy (FPR 5.0%). This makes the ‘combined test’ by far the best test for the detection of DS pregnancies in a low-risk population. The constant increase in maternal age at the time of delivery can also lead to an improved DR if a simple age-dependant protocol for DS detection is used, but only at the price of a much higher number of amniocenteses and subsequent abortions. The DR for DS can be increased much more markedly using the ‘combined test’ with a FPR that still remains at the level as it was in the early 1970s. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

12.
Nine centres collaborated to examine the feasibility of a screening method for trisomy 18 that was based on assigning individual risk, using a combination of maternal age and measurements of alpha-fetoprotein (AFP), unconjugated oestriol (uE3), and human chorionic gonadotropin (hCG). Second-trimester measurements of these analytes were obtained from 94 trisomy 18 pregnancies. In the 89 pregnancies without an associated open defect, the median levels for AFP, uE3, and hCG were 0.65, 0.43 and 0.36 multiples of the unaffected population median, respectively. The strongest individual predictor of risk for trisomy 18 was uE3, followed by hCG, AFP, and maternal age, in that order. Using a method of individual risk estimation that is based on the three markers and maternal age, 60 per cent of pregnancies associated with trisomy 18 would be detected at a risk cut-off level of 1:100, with a false-positive rate of about 0.2 per cent. One in nine pregnancies identified as being at increased risk for trisomy 18 would be expected to have an affected pregnancy. This risk-based screening method is more efficient than an existing method that is based on fixed analyte cut-off levels. Even though the birth prevalence of trisomy 18 is low, prenatal screening can be justified when performed in conjunction with Down syndrome screening and when a high proportion of women offered amniocentesis have an affected fetus.  相似文献   

13.
A prospective study was performed on 2119 pregnancies that underwent genetic amniocentesis. Indications for amniocentesis were either maternal age (⩾35) or triple-test results (risk⩾1/380). The study covered a 36-month period and assessed the prevalence of minor ultrasound markers both in fetuses with Down syndrome and normal control fetuses at 15–19 week' gestation. Only fetuses with normal karyotype or trisomy 21 were considered. Six minor sonographic markers were considered: nuchal thickness, pyelectasia, femur observed/expected and humerus observed/expected ratios, bowel echogenicity, and choroid plexus cysts. One or more ultrasound soft markers were present in 23 out of 33 fetuses with Down syndrome (70%) and in 572 out of 2069 normal fetuses (28%). Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

14.
Problems can arise in prenatal screening for Down syndrome when tests are performed in the first and second trimester and some women who have a negative first trimester test have a second trimester serum test. The second test result does not usually take account of the previous one being negative. Even if it does, it is often inaccurate. Using published data the extent of the error was examined. The age-specific risk of an affected pregnancy in such women will be lower than if no first trimester test had been performed. The distributions of the screening markers in affected and unaffected pregnancies will be different from those in unscreened women. If the appropriate age-specific risk and marker distributions are not used, error will arise. For example, a 35-year-old woman with nuchal translucency (NT), pregnancy-associated plasma protein-A (PAPP-A) and free β-human chorionic gonadotrophin (hCG) levels at the normal median would have a risk of 1 in 6500. If she then had the Triple Test with alpha-fetoprotein (AFP), unconjugated oestriol, and hCG levels of 0.7, 0.7 and 1.5 multiples of the median (MoM), respectively, her risk, ignoring the previous result, would be overestimated (1 in 95 compared with the correct estimate of 1 in 705). If the previous result was included, but the age-specific risk and second trimester marker distributions were not revised, her risk would be underestimated (1 in 820). If the correct age-specific risk and screening marker distributions were used, risk estimates would be accurate, but two tests would be less efficient than integrating all the screening information into a single test. The practice of offering second trimester serum screening to women who have already been screened is best avoided. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

15.
Maternal serum human thyroid-stimulating hormone (TSH) levels were investigated in chromosomally normal and Down syndrome pregnancies to determine whether TSH can be used as a marker for Down syndrome in the first trimester. Measurements were conducted on stored serum samples collected from 23 Down syndrome pregnancies and 115 unaffected pregnancies before chorionic villus sampling (CVS), between 9 and 11 completed weeks of pregnancy. The samples were matched for gestational age, maternal age, maternal weight and duration of storage of the serum sample. Maternal TSH concentration was slightly decreased in Down syndrome pregnancies, with a median of 0.84 multiples of the median (MoM). Maternal serum human chorionic gonadotropin (hCG) concentration was slightly elevated in Down syndrome pregnancies, with a median of 1.03 MoM. Both differences were not significant applying matched rank analysis (p=0.50 for TSH and p=0.43 for hCG). The association between TSH and hCG in unaffected pregnancies was also measured. The Spearman correlation coefficient between TSH and hCG was −0.21 which was statistically significant (p=0.02, 95% confidence interval −0.38 to −0.03). However, it was concluded that TSH is not a useful marker for distinguishing Down syndrome-affected pregnancies from normal pregnancies in the first trimester. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

16.
The aim of this study was to evaluate the concentration of CA 125 in second trimester amniotic fluid from Down syndrome pregnancies. CA 125 was measured in stored amniotic fluid samples from pregnancies of 14–19 weeks' gestation with and without Down syndrome fetuses. CA 125 levels were expressed in multiples of the median (MOM) for normal pregnancies of the same gestational age. Twenty-one pregnancies with Down syndrome fetuses and 63 unaffected controls matched for maternal age, gestational age, and duration of storage were studied. The median MOM values of the affected pregnancies were significantly higher than those of the controls (1·41 MOM versus 0·99 MOM). These findings show that there is an increased concentration of CA 125 in second-trimester amniotic fluid from Down syndrome pregnancies.  相似文献   

17.
Intrauterine fetal death occurred in four women who were ‘screen-positive’ in a screening programme for neural tube defects (NTDs) and Down syndrome (DS). These women had very high levels of maternal serum alpha-fetoprotein (MSAFP) and maternal serum human chorionic gonadotropin (MShCG). Therefore, we evaluated all ‘screen-positive’ women in whom both of these markers were ⩾ 2.0 multiples of the median. The cases fulfilling these criteria totalled 11, and only one of them had no complications. High concentrations of both MSAFP and MShCG in a number of these cases might have been caused by an increased placental volume, which, in turn, might have been induced by decreased perfusion of the placenta. We conclude that screening programmes wrongly determine a high risk of fetal NTD or DS if the concentrations of both these parameters are very high. Invasive diagnostic procedures should be avoided in these cases, particularly in view of the increased risk of an adverse pregnancy outcome.  相似文献   

18.
Screening for Down syndrome and other chromosomal aneuploidies by biochemical parameters in maternal serum is well established for the second trimester. With screening as late as 16 weeks of gestation, the option of chorionic villus sampling (CVS) unfortunately is lost. In our study population, the maternal serum alpha-fetoprotein (MSAFP) concentration was determined in 2471 women in the first trimester immediately prior to CVS. Although in this sample MSAFP tended to be lower in Down syndrome (DS) pregnancies than in pregnancies with a chromosomally normal fetus, at this early gestational age neither a fixed cut-off level of 0·5 multiples of the normal median (MOM) nor one of 0·6 MOM was suitable for identifying pregnancies at higher risk for DS. This also applied to trisomy 18, although on average MSAFP in trisomy 18 pregnancies was lower than in normal and DS pregnancies.  相似文献   

19.
Of the 65 328 pregnancies of South Australian mothers screened by the South Australian Maternal Serum Antenatal Screening (SAMSAS) Programme between 1 January 1991 and 31 December 1997, 3431 (5.25%) were declared at increased risk of fetal Down syndrome. Fetal or neonatal karyotype was determined in 2737/3431 (79.8%) of these pregnancies, including 16 with early fetal loss. Interrogation of the database of the South Australian Neonatal Screening Service showed 643 live-born infants whose phenotype was not subsequently questioned among the 694 pregnancies whose karyotype was not determined. Of the remaining 51/3431 pregnancies, 19 ended in early fetal loss without karyotyping and no newborn screening or other records could be found for 32 cases. The 129 instances of abnormal karyotype found were Down syndrome (84), trisomy 18 (four), trisomy 13 (three), triploidy (two), female sex chromosome aneuploidy (six) and male sex chromosome aneuploidy (five), inherited balanced rearrangements (19), mosaic or de novo balanced abnormalities (four) and unbalanced karyotypes (two). In the pregnancies declared at increased risk of fetal Down syndrome, only the karyotype for Down syndrome occurred with a frequency greater than that expected for the general, pregnant population. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

20.
Eighty-eight cases of abdominal wall defect with and without other lesions were ascertained by reviewing all labour room records in the West of Scotland, all surgical admissions to the Royal Hospital for Sick Children, Yorkhill, and all post mortems at Royal Hospital for Sick Children between 1978 and 1981. The affected cases comprised 39 terminations of pregnancy (17 of anterior abdominal wall defect without neural tube defect). 20 spontaneous stillbirths and 29 livebirths. All 10 cases of body stalk anomaly, 37.5 per cent of 16 gastroschisis cases and 53 per cent of 62 exomphalos cases had additional severe abnormalities. Abnormal karyotypes were present in seven out of 19 exomphalos cases but all karyotypes from 10 gastroschisis and 6 body stalk anomaly cases were normal. No correlation was found between the maternal serum AFP levels, the amniotic AFP levels and acetylcholinesterase results and the size of the lesion. It is proposed that anterior abdominal wall defects detected prenatally should have chromosome analysis and careful ultrasound to exclude associated severe anomalies before coming to a decision about termination. This policy was implemented in six pregnancies complicated by fetal gastroschisis without severe associated anomalies which were identified in the second trimester and continued to term. Immediate surgical repair was achieved in each case, although two of the infants succumbed from later complications of gastroschisis closure and one from respiratory distress syndrome. The remaining three infants made a satisfactory recovery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号