首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study compares an indoor-outdoor air-exchange mass balance model (IO model) with a chemical mass balance (CMB) model. The models were used to determine the contribution of outdoor sources and indoor resuspension activities to indoor particulate matter (PM) concentrations. Simultaneous indoor and outdoor measurements of PM concentration, chemical composition, and air-exchange rate were made for five consecutive days at a single-family residence using particle counters, nephelometers, and filter samples of integrated PM with an aerodynamic diameter of less than or equal to 2.5 microm (PM2.5) and PM with an aerodynamic diameter of less than or equal to 5 microm (PM5). Chemical compositions were determined by inductively coupled plasma mass-spectrometry. During three high-activity days, prescribed activities, such as cleaning and walking, were conducted over a period of 4-6 hr. For the remaining two days, indoor activities were minimal. Indoor sources accounted for 60-89% of the PM2.5 and more than 90% of the PM5 for the high-activity days. For the minimal-activity days, indoor sources accounted for 27-47% of PM2.5 and 44-60% of the PM5. Good agreement was found between the two mass balance methods. Indoor PM2.5 originating outdoors averaged 53% of outdoor concentrations.  相似文献   

2.
The effect of foot traffic on indoor particle resuspension was evaluated by associating non-prescribed foot traffic with simultaneous size-resolved airborne particulate matter (PM) concentrations in a northern California hospital. Foot traffic and PM were measured every 15 min in a carpeted hallway over two 27-h periods. The PM concentration in the hallway was modeled based on the foot traffic intensity, including the previous PM concentration via an autocorrelation regression method based on the well-mixed box model. All 5 size ranges of PM, ranging from 0.75–1 μm to 5–7.5 μm, were highly correlated with foot traffic measurements for both monitoring periods (p < 0.001, R2 = 0.87–0.90). However, correlations during daytime hours were less significant than nighttime. Coefficients found via this autoregressive analysis can be interpreted to reveal (i) time-independent contributions of walking activities on PM levels for a specific location; and (ii) size-specific characteristics of the resuspended PM.  相似文献   

3.
Concentrations of particulate matter (PM) and carbonaceous particulates in indoor and outdoor air at roadside private households were measured in Osaka, Japan. The particulate samples were collected on filters using a portable AND sampler capable of separating particles into three different size ranges: over 10 microm, 2-10 microm (coarse) and below 2 microm (fine) in aerodynamic diameter. The filters were weighed and then analyzed for elemental carbon (EC) and organic carbon (OC) by thermal oxidation using a CHN CORDER. The results showed that indoor fine PM concentration is considerably affected by fine EC and the fine EC in indoor air is significantly correlated to that in outdoor air, r=0.86 (n=30, p<0.001). A simple estimation from EC content ratio in diesel exhaust particles indicated that about 30% of indoor particulates of less than 10 microm (PM10) were contributed from diesel exhaust. Additionally, the size characteristics of outdoor PM at roadside and background sites were examined using Andersen Cascade Impactors.  相似文献   

4.
An exposure study of 18 subjects with chronic obstructive pulmonary disease (COPD) living in the Boston, MA, area was conducted. The objective was to examine determinants of personal exposures to particulate matter (PM) with aerodynamic diameters of less than 2.5 microm (PM2.5), less than 10 microm (PM10), and between 2.5 and 10 microm (PM2.5-10). In a previous publication, the analyses of the longitudinal individual-specific relationships among indoor, outdoor, and personal levels showed that the relationships varied by subject and by particle size fraction. In the present paper, statistical and physical models were used to examine personal PM2.5, PM10, and PM2.5-10 exposure covariates. Results indicated that time-weighted indoor concentrations were significant predictors of personal PM2.5, PM10, and PM2.5-10 exposures. Also, time-weighted outdoor concentrations, time spent near smokers, and time spent during transportation were important predictors for PM2.5 but not for personal PM2.5-10 exposures. In turn, time spent cleaning contributed to all size-fraction personal exposures, whereas cooking affected only personal PM2.5-10 exposures. The findings showed that the relationship between personal PM2.5 exposures and the corresponding ambient concentrations was influenced by home air exchange rates (or by ventilation status). Because the particle properties or components causing the health effects are unknown, it is not certain to what extent the risk posed by ambient particles can be reduced by controlling any one of these factors.  相似文献   

5.
Hourly indoor and outdoor fine particulate matter (PM2.5), organic and elemental carbon (OC and EC, respectively), particle number (PN), ozone (O3), carbon monoxide (CO), and nitrogen oxide (NOx) concentrations were measured at two different retirement communities in the Los Angeles, CA, area as part of the Cardiovascular Health and Air Pollution Study. Site A (group 1 [G1]) was operated from July 6 to August 20, 2005 (phase 1 [P1]) and from October 19 to December 10, 2005 (P2), whereas site B (group 2 [G2]) was operated from August 24 to October 15, 2005 (P1), and from January 4 to February 18, 2006 (P2). Overall, the magnitude of indoor and outdoor measurements was similar, probably because of the major influence of outdoor sources on indoor particle and gas levels. However, G2 showed a substantial increase in indoor OC, PN, and PM2.5 between 6:00 and 9:00 a.m., probably from cooking. The contributions of primary and secondary OC (SOA) to measured outdoor OC were estimated from collected OC and EC concentrations using EC as a tracer of primary combustion-generated OC (i.e., "EC tracer method"). The study average outdoor SOA accounted for 40% of outdoor particulate OC (40-45% in the summer and 32-40% in the winter). Air exchange rates (hr(-1)) and infiltration factors (Finf; dimensionless) at each site were also determined. Estimated Finf and measured particle concentrations were then used in a single compartment mass balance model to assess the contributions of indoor and/or outdoor sources to measured indoor OC, EC, PM2.5, and PN. The average percentage contributions of indoor SOA of outdoor origin to measured indoor OC were approximately 35% (during G1P1 and G1P2) and approximately 45% (for G2P1 and G2P2). On average, 36% (G2P1) to 44% (G1P1) of measured indoor OC was composed of outdoor-generated primary OC.  相似文献   

6.
Mechanically produced abrasion particles and resuspension processes are responsible for a significant part of the PM10 emissions of road traffic. However, specific differentiation between PM10 emissions due to abrasion and resuspension from road pavement is very difficult due to their similar elemental composition and highly correlated variation in time. In this work Mobile Load Simulators were used to estimate PM10 emission factors for pavement abrasion and resuspension on different pavement types for light and heavy duty vehicles.From the experiments it was derived that particle emissions due to abrasion from pavements in good condition are quite low in the range of only a few mg·km?1 per vehicle if quantifiable at all. Considerable abrasion emissions, however, can occur from damaged pavements. Resuspension of deposited dust can cause high and extremely variable particle emissions depending strongly on the dirt load of the road surface. Porous pavements seem to retain deposited dust better than dense pavements, thus leading to lower emissions due to resuspension compared to pavements with a dense structure (e.g. asphalt concrete). Tyre wear seemed not to be a quantitatively significant source of PM10 emissions from road traffic.  相似文献   

7.
This paper reviews the effects and control methods for particulate matter (PM) in animal indoor environments. PM in animal indoor environments represents a particular threat to the health of countless animals and millions of workers around the world. Because air in animal facilities has a higher portion of biological content than does air in other environments, the adverse health impact is much greater than it is for the same amount of PM in other environments. Source control, ventilation, and internal air cleaning can reduce PM concentration in animal indoor environments. Source control is typically the most economical method for PM control. Ventilation is the most widely applied technology, although uncertainties remain as to its effectiveness for PM control. Most internal air cleaners require frequent maintenance because of the high concentration and stickiness of PM in animal environments. Filtration is the most well-studied and widely used technology for internal air cleaning because of its low capital cost and high efficiency. Several trials using electrostatic precipitators have shown efficiencies of approximately 50% in removing PM concentration, but improvements are needed before they can be used widely. No report using wet collectors or centrifugals as internal air cleaners has been found.  相似文献   

8.
室内空气中颗粒物污染特征研究   总被引:1,自引:0,他引:1  
为获得室内空气颗粒物污染特征,2009年8月18~24日在某单位工作及生活区选取4个室内点和1个室外点进行颗粒物采样和成分分析.结果表明,室内粗颗粒(PM10)符合<室内空气质量标准>(GB/T 18883-2002),而细粒子(PM2.5)的浓度水平较高,表明室内PM2.5的污染较重;室内与室外PM2.5比值显示,P...  相似文献   

9.
As part of a large exposure assessment and health-effects panel study, 33 trace elements and light-absorbing carbon were measured on 24-hr fixed-site filter samples for particulate matter with an aerodynamic diameter <2.5 microm (PM2.5) collected between September 26, 2000, and May 25, 2001, at a central outdoor site, immediately outside each subject's residence, inside each residence, and on each subject (personal sample). Both two-way (PMF2) and three-way (PMF3) positive matrix factorization were used to deduce the sources contributing to PM2.5. Five sources contributing to the indoor and outdoor samples were identified: vegetative burning, mobile emissions, secondary sulfate, a source rich in chlorine, and a source of crustal-derived material. Vegetative burning contributed more PM2.5 mass on average than any other source in all microenvironments, with average values estimated by PMF2 and PMF3, respectively, of 7.6 and 8.7 microg/m3 for the outdoor samples, 4 and 5.3 microg/m3 for the indoor samples, and 3.8 and 3.4 microg/m3 for the personal samples. Personal exposure to the combustion-related particles was correlated with outdoor sources, whereas exposure to the crustal and chlorine-rich particles was not. Personal exposures to crustal sources were strongly associated with personal activities, especially time spent at school among the child subjects.  相似文献   

10.
The associations between residential outdoor and ambient particle mass, fine particle absorbance, particle number (PN) concentrations, and residential and traffic determinants were investigated in four European urban areas (Helsinki, Athens, Amsterdam, and Birmingham). A total of 152 nonsmoking participants with respiratory diseases, not exposed to occupational pollution, were included in the study, which comprised a 7-day intensive exposure monitoring period of both indoor and home outdoor particle mass and number concentrations. The same pollutants were also continuously measured at ambient fixed sites centrally located to the studied areas (fixed ambient sites). Relationships between concentrations measured directly outside the homes (residential outdoor) and at the fixed ambient sites were pollutant-specific, with substantial variations among the urban areas. Differences were more pronounced for coarse particles due to resuspension of road dust and PN, which is strongly related to traffic emissions. Less significant outdoor-to-fixed variation for particle mass was observed for Amsterdam and Birmingham, predominantly due to regional secondary aerosol. On the contrary, a strong spatial variation was observed for Athens and to a lesser extent for Helsinki. This was attributed to the overwhelming and time-varied inputs from traffic and other local sources. The location of the residence and traffic volume and distance to street and traffic light were important determinants of residential outdoor particle concentrations. On average, particle mass levels in suburban areas were less than 30% of those measured for residences located in the city center. Residences located less than 10 m from a street experienced 133% higher PN concentrations than residences located further away. Overall, the findings of this multi-city study, indicated that (1) spatial variation was larger for PN than for fine particulate matter (PM) mass and varied between the cities, (2) vehicular emissions in the residential street and location in the center of the city were significant predictors of spatial variation, and (3) the impact of traffic and location in the city was much larger for PN than for fine particle mass.  相似文献   

11.
Continuous data of the concentration measurements of respirable suspended particulates (PM10, particles with aerodynamic diameter smaller than or equal to 10 pm) were analyzed. These measurements were carried out at an urban and nearby industrial location in northern Greece for the 5-year period 1996-2000. The time series concentration trend was examined, the seasonal and diurnal variations were identified, and the lognormality of the daily mean concentration data sets was tested. Over the 5-year data-gathering period, the days on which the U.S. Environmental Protection Agency (EPA) 24-hr PM10 standard was exceeded (episode days) were identified and their relation to prevailing synoptic-scale meteorological conditions was studied. The analysis led to useful information concerning the air quality levels, the contribution of the main pollution sources in this area, as well as some of the mechanisms that influence the PM10 concentrations. It also was proved that the measured PM10 concentrations are a result of a combination of processes including local anthropogenic sources, mesoscale transport, and resuspension. A complex system of sources and meteorological conditions modulate the heavy particulate pollution in the area of interest.  相似文献   

12.
Abstract

The associations between residential outdoor and ambient particle mass, fine particle absorbance, particle number (PN) concentrations, and residential and traffic determinants were investigated in four European urban areas (Helsinki, Athens, Amsterdam, and Birmingham). A total of 152 nonsmoking participants with respiratory diseases, not exposed to occupational pollution, were included in the study, which comprised a 7-day intensive exposure monitoring period of both indoor and home outdoor particle mass and number concentrations. The same pollutants were also continuously measured at ambient fixed sites centrally located to the studied areas (fixed ambient sites). Relationships between concentrations measured directly outside the homes (residential outdoor) and at the fixed ambient sites were pollutant-specific, with substantial variations among the urban areas. Differences were more pronounced for coarse particles due to resuspension of road dust and PN, which is strongly related to traffic emissions. Less significant outdoor-to-fixed variation for particle mass was observed for Amsterdam and Birmingham, predominantly due to regional secondary aerosol. On the contrary, a strong spatial variation was observed for Athens and to a lesser extent for Helsinki. This was attributed to the overwhelming and time-varied inputs from traffic and other local sources. The location of the residence and traffic volume and distance to street and traffic light were important determinants of residential outdoor particle concentrations. On average, particle mass levels in suburban areas were less than 30% of those measured for residences located in the city center. Residences located less than 10 m from a street experienced 133% higher PN concentrations than residences located further away. Overall, the findings of this multi-city study, indicated that (1) spatial variation was larger for PN than for fine particulate matter (PM) mass and varied between the cities, (2) vehicular emissions in the residential street and location in the center of the city were significant predictors of spatial variation, and (3) the impact of traffic and location in the city was much larger for PN than for fine particle mass.  相似文献   

13.
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. Implications: Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.  相似文献   

14.
An indoor size-dependent particulate matter (PM) transport approach is developed to investigate coarse PM (PM10), fine PM (PM2.5), and very fine PM (PM1) removal behaviors in a ventilated partitioned indoor environment. The approach adopts the Eulerian large eddy simulation of turbulent flow and the Lagrangian particle trajectory tracking to solve the continuous airflow phase and the discrete particle phase, respectively. Model verification, including sensitivity tests of grid resolution and particle numbers, is conducted by comparison with the full-size experiments conducted previously. Good agreement with the measured mass concentrations is found. Numerical scenario simulations of the effect of ventilation patterns on PM removal are performed by using three common ventilation patterns (piston displacement, mixing, and cross-flow displacement ventilation) with a measured indoor PM10 profile in the Taipei metropolis as the initial condition. The temporal variations of suspended PM10, PM2.5, and PM1 mass concentrations and particle removal mechanisms are discussed. The simulated results show that for all the of the three ventilation patterns, PM2.5 and PM1 are much more difficult to remove than PM10. From the purpose of health protection for indoor occupants, it is not enough to only use the PM10 level as the indoor PM index. Indoor PM2.5 and PM1 levels should be also considered. Cross-flow displacement ventilation is more effective to remove all PM10, PM2.5, and PM1 than the other ventilation patterns. Displacement ventilation would result in more escaped particles and less deposited particles than mixing ventilation.  相似文献   

15.
Paired indoor and outdoor concentrations of fine and coarse particulate matter (PM), PM2.5 reflectance [black carbon(BC)], and nitrogen dioxide (NO2) were determined for sixteen weeks in 2008 at four elementary schools (two in high and two in low traffic density zones) in a U.S.-Mexico border community to aid a binational health effects study. Strong spatial heterogeneity was observed for all outdoor pollutant concentrations. Concentrations of all pollutants, except coarse PM, were higher in high traffic zones than in the respective low traffic zones. Black carbon and NO2 appear to be better traffic indicators than fine PM. Indoor air pollution was found to be well associated with outdoor air pollution, although differences existed due to uncontrollable factors involving student activities and building/ventilation configurations. Results of this study indicate substantial spatial variability of pollutants in the region, suggesting that children’s exposures to these pollutants vary based on the location of their school.  相似文献   

16.
A study of carbonaceous aerosol was initiated in Nanchang, a city in eastern China, for the first time. Daily and diurnal (daytime and nighttime) PM2.5 (particulate matter with aerodynamic diameter < or =2.5 microm) samples were collected at an outdoor site and in three different indoor environments (common office, special printing and copying office, and student dormitory) in a campus of Nanchang University during summer 2009 (5-20 June). Daily PM10 (particulate matter with aerodynamic diameter < or =10 microm) samples were collected only at the outdoor site, whereas PM2.5 samples were collected at both indoor and outdoor sites. Loaded PM2.5 and PM10 samples were analyzed for organic and elemental carbon (OC, EC) by thermal/optical reflectance following the Interagency Monitoring of Protected Visual Environments-Advanced (IMPROVE-A) protocol. Ambient mass concentrations of PM10 and PM2.5 in Nanchang were compared with the air quality standards in China and the United States, and revealed high air pollution levels in Nanchang. PM2.5 accounted for about 70% of PM10, but the ratio of OC and EC in PM2.5 to that in PM10 was higher than 80%, which indicated that OC and EC were mainly distributed in the fine particles. The variations of carbonaceous aerosol between daytime and nighttime indicated that OC was released and formed more rapidly in daytime than in nighttime. OC/EC ratios were used to quantify secondary organic carbon (SOC). The differences in SOC and SOC/OC between daytime and nighttime were useful in interpreting the secondary formation mechanism. The results of (1) OC and EC contributions to PM2.5 at indoor sites and the outdoor site; (2) indoor-outdoor correlation of OC and EC; (3) OC-EC correlation; and (4) relative contributions of indoor and outdoor sources to indoor carbonaceous aerosol indicated that OC indoor sources existed in indoor sites, with the highest OC emissions in I2 (the special printing and copying office), and that indoor EC originated from outdoor sources. The distributions of eight carbon fractions in emissions from the printer and copier showed obviously high OC1 (>20%) and OC2 (approximately 30%), and obviously low EC1-OP (a pyrolyzed carbon fraction) (<10%), when compared with other sources.  相似文献   

17.
18.
INTENTION, GOAL, SCOPE, BACKGROUND: As the strong negative health effect of exposure to the inhalable particulate matter PM10 in the urban environment has been confirmed, the study of the mass concentrations, physico-chemical characteristics, sources, as well as spatial and temporal variation of atmospheric aerosol particles becomes very important. OBJECTIVE: This work is a pilot study to assess the concentration level of ambient suspended particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade central urban area. Average daily concentrations of PM10 and PM2.5 have been measured at three representative points in the city between June 2002 and December 2002. The influence of meteorological parameters on PM10 and PM2.5 concentrations was analyzed, and possible pollution sources were identified. METHODS: Suspended particles were collected on Pure Teflon filters by using a Mini-Vol low-volume air sampler (Airmetrics Co., Inc.; 5 l min(-1) flow rate). Particle mass was determined gravimetrically after 48 h of conditioning in a desiccator, in a Class 100 clean room at the temperature T = 20 degrees C and at about 50% constant relative humidity (RH). RESULTS AND DISCUSSION: Analysis of the PM10 data indicated a marked difference between season without heating--(summer; mean value 56 microg m(-3)) and heating season--(winter; mean value 96 microg m3); 62% of samples exceeded the level of 50 microg m(-3). The impact of meteorological factors on PM concentrations was not immediately apparent, but there was a significant negative correlation with the wind speed. CONCLUSIONS: The PM10 and PM2.5 mass concentrations in the Belgrade urban area had high average values (77 microg m(-3) and 61 microg m(-3)) in comparison with other European cities. The main sources of particulate matter were traffic emission, road dust resuspension, and individual heating emissions. When the air masses are coming from the SW direction, the contribution from the Obrenovac power plants is evident. During days of exceptionally severe pollution, in both summer and winter periods, high production of secondary aerosols occurred, as can be seen from an increase in PM2.5 in respect to PM10 mass concentration. RECOMMENDATION AND OUTLOOK: The results obtained gave us the first impression of the concentration level of particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade ambient air. Due to measured high PM mass concentrations, it is obvious that it would be very difficult to meet the EU standards (EEC 1999) by 2010. It is necessary to continue with PM10 and PM2.5 sampling; and after comprehensive analysis which includes the results of chemical and physical characterization of particles, we will be able to recommend effective control measures in order to improve air quality in Belgrade.  相似文献   

19.
The extent of mass loss on Teflon filters caused by ammonium nitrate volatilization can be a substantial fraction of the measured particulate matter with an aerodynamic diameter less than 2.5 microm (PM2.5) or 10 microm (PM10) mass and depends on where and when it was collected. There is no straightforward method to correct for the mass loss using routine monitoring data. In southern California during the California Acid Deposition Monitoring Program, 30-40% of the gravimetric PM2.5 mass was lost during summer daytime. Lower mass losses occurred at more remote locations. The estimated potential mass loss in the Interagency Monitoring of Protected Visual Environments network was consistent with the measured loss observed in California. The biased mass measurement implies that use of Federal Reference Method data for fine particles may lead to control strategies that are biased toward sources of fugitive dust, other primary particle emission sources, and stable secondary particles (e.g., sulfates). This analysis clearly supports the need for speciated analysis of samples collected in a manner that preserves volatile species. Finally, although there is loss of volatile nitrate (NO3-) from Teflon filters during sampling, the NO3- remaining after collection is quite stable. We found little loss of NO3- from Teflon filters after 2 hr under vacuum and 1 min of heating by a cyclotron proton beam.  相似文献   

20.
Investigations on the monitoring of ambient air levels of atmospheric particulates were developed around a large source of primary anthropogenic particulate emissions: the industrial ceramic area in the province of Castelló (Eastern Spain). Although these primary particulate emissions have a coarse grain-size distribution, the atmospheric transport dominated by the breeze circulation accounts for a grain-size segregation, which results in ambient air particles occurring mainly in the 2.5–10 μm range. The chemical composition of the ceramic particulate emissions is very similar to the crustal end-member but the use of high Al, Ti and Fe as tracer elements as well as a peculiar grain-size distribution in the insoluble major phases allow us to identify the ceramic input in the bulk particulate matter. PM2.5 instead of PM10 monitoring may avoid the interference of crustal particles without a major reduction in the secondary anthropogenic load, with the exception of nitrate. However, a methodology based in PM2.5 measurement alone is not adequate for monitoring the impact of primary particulate emissions (such as ceramic emissions) on air quality, since the major ambient air particles derived from these emissions are mainly in the range of 2.5–10 μm. Consequently, in areas characterised by major secondary particulate emissions, PM2.5 monitoring should detect anthropogenic particulate pollutants without crustal particulate interference, whereas PM10 measurements should be used in areas with major primary anthropogenic particulate emissions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号