首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
The uncontrolled burning of household waste in barrels has recently been implicated as a major source of airborne emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). A detailed, systematic study to understand the variables affecting emissions of PCDD/Fs from burn barrels was performed. The waste composition, fullness of the barrel, and the combustion conditions within the barrel all contribute significantly to determining the emissions of PCDD/Fs from burn barrels. The study found no statistically significant effect on emissions from the Cl content of waste except at high levels, which are not representative of typical household waste. At these elevated Cl concentrations, the impact of Cl on PCDD/F emissions was found to be independent of the form of the Cl (inorganic or organic). For typical burn conditions, most of the PCDD/F emissions appear to be associated with the later stages of the burn when the waste is smoldering. Polychlorinated biphenyls (PCBs) were also measured for a subset of the tests. For the nominal waste composition, the average emissions were 76.8 ng toxic equivalency units (TEQ)WHO98/kg of waste combusted, which suggests that uncontrolled burning of household waste could be a major source of airborne PCDD/Fs in the United States.  相似文献   

2.
Leclerc D  Duo WL  Vessey M 《Chemosphere》2006,63(4):676-689
This paper discusses the effects of combustion conditions on PCDD/PCDF emissions from pulp and paper power boilers burning salt-laden wood waste. We found no correlation between PCDD/PCDF emissions and carbon monoxide emissions. A good correlation was, however, observed between PCDD/PCDF emissions and the concentration of stack polynuclear aromatic hydrocarbons (PAHs) in the absence of TDF addition. Thus, poor combustion conditions responsible for the formation of products of incomplete combustion (PICs), such as PAHs and PCDD/PCDF precursors, increase PCDD/PCDF emissions. PAH concentrations increased with higher boiler load and/or low oxygen concentrations at the boiler exit, probably because of lower available residence times and insufficient excess air. Our findings are consistent with the current understanding that high ash carbon content generally favours heterogeneous reactions leading to either de novo synthesis of PCDD/PCDFs or their direct formation from precursors. We also found that, in grate-fired boilers, a linear increase in the grate/lower furnace temperature produces an exponential decrease in PCDD/PCDF emissions. Although the extent of this effect appears to be mill-specific, particularly at low temperatures, the results indicate that increasing the combustion temperature may decrease PCDD/PCDF emissions. It must be noted, however, that there are other variables, such as elevated ESP and stack temperatures, a high hog salt content, the presence of large amounts of PICs and a high Cl/S ratio, which contribute to higher PCDD/PCDFs emissions. Therefore, higher combustion temperatures, by themselves, will not necessarily result in low PCDD/PCDFs emissions.  相似文献   

3.
Ryu JY  Choi KC  Mulholland JA 《Chemosphere》2006,65(9):1526-1536
Polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) byproducts can be formed in combustion systems by a variety of mechanisms. While total PCDD/F emissions and, to a lesser extent, homologue distributions from incinerators have been found to vary widely depending on combustion conditions, PCDD/F isomer distributions do not. Formation mechanisms can be grouped into two general categories: condensation of precursors, such as chlorinated phenols, and formation from particulate carbon, termed de novo synthesis. In addition to these mechanisms, chlorination and dechlorination reactions may affect isomer patterns. In this work, isomer patterns from field and laboratory municipal waste combustion samples are compared with computed thermodynamic distributions and those from the following experimental investigations: both gas-phase and metal-catalyzed condensation of chlorinated phenols, chlorination of dibenzo-p-dioxin and dibenzofuran, and dechlorination of octachlorodibenzo-p-dioxin and octachlorodibenzofuran. PCDD/F isomer patterns produced by different formation mechanisms in controlled experiments are distinct and robust, largely unaffected by combustion conditions. PCDD isomer patterns from municipal waste combustion are most similar to those produced by CuCl(2)-catalyzed phenol condensation from 10 chlorinated phenols. PCDF isomer patterns are most similar to those produced by chlorination and dechlorination.  相似文献   

4.
Hübner C  Boos R  Prey T 《Chemosphere》2005,58(3):367-372
Within this project the emissions into the atmosphere of polychlorinated dibenzo-p-dioxins and -furans (PCDD/F) of 30 domestic heating appliances in Austrian households were tested. The appliances were single stoves (kitchen stove, continuous burning stove and tiled stove) and central heating boilers for solid fuels up to a nominal heat input of 50 kW. A main objective of this survey was to determine the PCDD/F emissions of domestic heating units under routine conditions. Therefore, the habitual combustion conditions used by the operators were not influenced. The original fuels and lightning supports were used and the operation of the units was carried out by the householders according to their usual practice. The data obtained were used to calculate in-field PCDD/F-emission factors. Most of the appliances have shown PCDD/F emissions within a concentration range of 0.01-0.3 ng TEQ/MJ. Modern fan-assisted wood heating boilers with afterburning and units for continuously burning of wood chips and wood pellets had the lowest emissions. High emissions were caused by unsuitable heating habits such as combustion of wastes and inappropriate operation of the appliances. There were only small differences between single stoves and central heating boilers or between wood and coal-fired appliances. The emission factors calculated are higher than those cited in literature, which are mainly derived from trials on test stands under laboratory conditions.  相似文献   

5.
P.W. Cains  P. Dyke 《Chemosphere》1994,28(12):2101-2119
The UK Department of Trade and Industry funded extensive studies into the emissions from a variety of small scale waste combustion plants. In this paper we analyse the data on polychlorinated dibenzodioxin and polychlorinated dibenzofuran (PCDD/F) emissions from these studies. We conclude that simple correlations of PCDD/F emissions against parameters such as carbon monoxide, hydrogen chloride, feedstock composition, combustion or boiler exit temperature do not provide any guide to the emission of PCDD/F. The complex interaction between the varying fuel properties and the design features of combustion equipment mean that a greater understanding of the fundamental mechanisms is required to ensure effective control of PCDD/F at a reasonable cost.  相似文献   

6.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   

7.
Duo W  Leclerc D 《Chemosphere》2007,67(9):S164-S176
Both organic chlorine (e.g. PVC) and inorganic chlorides (e.g. NaCl) can be significant chlorine sources for dioxin and furan (PCDD/F) formation in combustion processes. This paper presents a thermodynamic analysis of high temperature salt chemistry. Its influence on PCDD/F formation in power boilers burning salt-laden wood waste is examined through the relationships between Cl2, HCl, NaCl(g) and NaCl(c). These analyses show that while HCl is a product of combustion of PVC-laden municipal solid waste, NaCl can be converted to HCl in hog fuel boilers by reactions with SO2 or alumino-silicate materials. Cl2 is a strong chlorinating agent for PCDD/F formation. HCl can be oxidized to Cl2 by O2, and Cl2 can be reduced back to HCl by SO2. The presence of sulphur at low concentrations thus enhances PCDD/F formation by increasing HCl concentrations. At high concentrations, sulphur inhibits de novo formation of PCDD/Fs through Cl2 reduction by excess SO2. The effect of NH3, CO and NOx on PCDD/F formation is also discussed. A semi-empirical kinetic model is proposed. This model considers both precursor and de novo formation mechanisms. A simplified version is used as a stack emission model. The kinetic model indicates that stack dioxin emissions will increase linearly with decreasing electrostatic precipitator (ESP) efficiency and exponentially with increasing ESP temperature.  相似文献   

8.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

9.
Open burning for waste disposal is, in many countries, the dominant source of polychlorinated dibenzodioxins, dibenzofurans and biphenyls (PCDD/PCDF/PCB) release to the environment. To generate emission factors for open burning, experimental pile burns of about 100 kg of household waste were conducted with emissions sampling. From these experiments and others conducted by the same authors it is found that less compaction of waste or active mixing during the fire - “stirring” - promotes better combustion (as evidenced by lower CO/CO2 ratio) and reduces emissions of PCDD/PCDF/PCB; an intuitive but previously undemonstrated result. These experiments also support previous results suggesting PCDD/PCDF/PCB generation in open burning - while still highly variable - tends to be greater in the later (smoldering) phases of burning when the CO/CO2 ratio increases.  相似文献   

10.
Urea as a PCDD/F inhibitor in municipal waste incineration   总被引:2,自引:0,他引:2  
Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at approximately 730 degrees C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

11.
ABSTRACT

Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at ~730 °C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

12.
ABSTRACT

Emissions of polychlorinated dibenzo-p-dioxins and poly-chlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alk-ene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alk-enes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

13.
Atmospheric fate and transport of dioxins: local impacts   总被引:1,自引:0,他引:1  
Lohman K  Seigneur C 《Chemosphere》2001,45(2):161-171
We conducted model simulations of the atmospheric fate and transport of PCDD/F to assess the fraction of emitted PCDD/F that would deposit within 100 km from the source. We considered eight major categories of PCDD/F emission sources and six different locations, to cover a wide range of source characteristics, PCDD/F congener profiles and particle size distributions, meteorological conditions and terrain configurations. These results suggest that for sources that have tall stacks and/or high plume rise (e.g., copper smelters, cement kilns, sinter plants), only a small fraction of PCDD/F emissions is deposited locally (typically, less than 10% within 100 km). Other source categories such as municipal solid waste incinerators, medical waste incinerators and diesel trucks lead to a greater fraction of PCDD/F being deposited locally; nevertheless, the majority of their PCDD/F emissions tends to be transported beyond 100 km. Although local impacts may need to be addressed for these latter source categories, it appears that the long-range potential impacts of PCDD/F need to be addressed for all source categories. Sensitivity studies were conducted to investigate the effect of various key model inputs on simulation results. These studies suggest that an advanced atmospheric dispersion model should be used for cases where PCDD/F emissions may present some local concerns because the results are very sensitive to the treatment of dispersion. Also, it is essential to obtain accurate characterizations of the particle size distribution of particulate PCDD/F because the dry deposition flux is very sensitive to the particle size distribution.  相似文献   

14.
The results of an assessment study of both industrial and non-industrial dioxin and furan (PCDD/Fs) emissions in the Lombardy Region (Italy) are outlined below. The main data source refer to 1997, and are compiled from the Lombardy Emissions Inventory (developed under the framework of the Regional Air Quality Plan) together with documented emissions factors available. Due to the uncertain nature of the emissions assessment, results are provided as a most probable value within a given range. Total PCDD/Fs emissions in Lombardy average 33 g I-TEQ y(-1), ranging from minimum 13 g I-TEQ y(-1) to maximum 88 g I-TEQ y(-1). The main PCDD/Fs sources are waste incineration, electric arc furnace for steel production, vehicle diesel combustion and residential wood combustion. Incineration emission factors are expected to decrease over the period 2005-2010, in compliance with legal requirements. This will prioritize control over the remaining main PCDD/Fs contributors. Due to limited information available concerning this data, the accuracy of which is uncertain, further research is needed to evaluate the future role of these sources.  相似文献   

15.
Annual emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from open burning of crop residues in each province of China mainland between 1997 and 2004 were estimated to be ranged from 1.38x10(3) to 1.52x10(3) g I-TEQ/yr, with the average of 1.50+/-0.08x10(3) g I-TEQ/yr, which contributed to approximately 10% approximately 20% of the total emissions in China. The PCDD/F emissions mainly occurred in the largest crop-producing provinces, especially in those of higher economic levels. The major sources of PCDD/F emissions from open burning in China were found to be cereal residues (i.e. rice, wheat, and corn), which accounted about 70% of the total emissions. Moreover, the first-order one-variable grey differential equation model (GM (1,1) model) for annual emissions of PCDD/Fs was established based on grey system theory. The GM (1,1) model was proved to be robust to predict the annual PCDD/F emissions from crop residue field burning in forthcoming years.  相似文献   

16.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

17.
Dyke PH  Sutton M  Wood D  Marshall J 《Chemosphere》2007,67(7):1275-1286
This paper reports on an intensive study into releases of polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated furans (PCDF) and polychlorinated biphenyls (PCB) from a diesel engine and the analysis of PCDD/F and PCB in crankcase lubricating oil. Experimental conditions were set and carefully controlled in order to maximize the possible impact of, and our ability to measure the effect of, changes in the levels of chlorine in the lubricant. Emissions to air were measured using modified EPA methods following the principles of the European EN 1948 standards. A series of 40 experimental runs were completed using three reference lubricants formulated to have three levels of chlorine present as a residual component (at levels of 12, 131 and 259 mg kg(-1) or ppm). The engine was run with and without the diesel oxidation catalyst. All lubricants were realistic oils and the use of unrealistic additives or doping of components - particularly chlorine - in the fuel and lubricant was carefully avoided. Analysis of fuel and lubricant (before and after testing) samples required strenuous attention to achieve acceptable recoveries and showed non-detectable levels of PCB and PCDD/F at a detection limit of around 1.5 ng I-TEQ kg(-1) (ppt), indistinguishable from the laboratory blank. The testing demonstrated the need for extreme care to be taken in developing measurement methods that are sufficiently sensitive for measuring chlorine content of fluids and PCDD/F in oils, the latter being particularly challenging. Mean emissions of PCDD/F with the diesel oxidation catalyst in place were 23 pg I-TEQ l(-1) of fuel and with the diesel oxidation catalyst removed 97 pg I-TEQ l(-1) of fuel. The results of this testing showed that the emissions of PCDD/F were greatly reduced by the presence of a diesel oxidation catalyst in the exhaust, a finding that has not been explicitly tested in previous work. They also show that emissions from the engine were not controlled by the level of chlorine in the lubricant and that emissions did not change in response to a much greater step change in the total chlorine entering the combustion chamber due to a change in the level of chlorine in the fuel. Emissions when the engine was configured with a diesel oxidation catalyst showed a consistent pattern that appears to be unique in the experience of the authors.  相似文献   

18.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

19.
PCDD/Fs are one of the most studied molecules in the world because of their toxicity. In the last years the toxicity of these compounds has been analyzed in details. For years PCDD/F inventories have pointed out the significant role of municipal solid waste (MSW) incinerators in the overall balance. Recently, thanks to new regulations on PCDD/F emissions, in a few countries this scenario is changing: it can be demonstrated that modern MSW incinerators can play a secondary role even if the percentage of MSW sent to combustion has increased. In the latest inventories an unconventional source of PCDD/F has appeared: in nineties some biogas characterizations have demonstrated that there is a release of PCDD/F from MSW sanitary landfills. In addition, the combustion of collected biogas can generate not negligible amounts of PCDD/F. A new question can be put: does the MSW contribute with other management options to the overall balance of PCDD/F? The present work points out that a detailed inventory should take into account also the PCDD/F release from bio-mechanical treatment plants (both composting and bio-drying/bio-stabilization plants). However the contribution from this option is secondary when it is compared with the one from old MSW incinerators.  相似文献   

20.
William F. Carroll  Jr.   《Chemosphere》2001,45(8):1173-1180
Emissions of PCDD/F from poly(vinyl chloride) (PVC) burned in house fires has been estimated at <1 g I-TEQ/yr in the US. In the current literature-based study, amounts of wood (21,000 kg) and PVC (180 kg) in a new house of standard construction are calculated and previously published emission factors for wood (0.01–173 μg/t) and PVC (3–6554 μg/t) are reported. Test conditions under which emission factors are generated differ and may not be directly comparable. Typically, PVC is tested at small-scale under relatively poor combustion conditions and wood is tested at large-scale under good combustion conditions. Thus, overall emission from combustion of these two materials of construction in house fires on an as-used basis is estimated to be similar (on the order of 1 g/yr) and a small contributor to the PCDD/F sources inventory. No speculation is made with respect to contents, roofing or other materials of construction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号