首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A sensitive and accurate analytical method based on dispersive liquid-liquid microextraction was developed for the simultaneous determination of selected pesticides, hormones, and endocrine disruptors by GC-MS. The optimum conditions of the extraction procedure were determined using an experimental design of factors significantly affecting the extraction output. Analysis of variance (ANOVA) was used to evaluate the main effects of experimental factors and their interactions. The limit of detection values determined for the analytes under optimum experimental conditions were found to be between 0.30–2.0 ng/mL. The linear calibration plot of analytes span across a wide concentration range and low %RSD values from replicate measurements indicated good precision of the developed method. Spiked recovery tests were also performed on municipal wastewater, well water, lake water, sea water, and tap water matrices to determine the method’s accuracy and applicability to water samples. The recovery results obtained were satisfactory for all water samples.  相似文献   

2.
This study describes the determination of trace levels of copper by slotted quartz tube atomic absorption spectrometry after dispersive liquid-liquid microextraction. A ligand synthesized from the reaction of salicylaldehyde and 1-naphthylamine was used to form coordinate copper complex prior to extraction. All parameters that influence the output of complex formation, extraction, and instrumental measurement were optimized to enhance the absorbance signal of copper. Under the optimum conditions, about 104-fold enhancement in sensitivity was recorded over the conventional flame atomic absorption spectrometer, corresponding to a 0.51 ng/mL detection limit. The percent relative standard deviation calculated for the lowest concentration (4.8%) indicated high precision for the experimental procedure. Accuracy and applicability of the optimum method were determined by performing spiked recovery tests on urine, lake water, and mineral water samples. Satisfactory recovery results were obtained between 82.2 and 106.3% at four different concentrations. Matrix matching method was also performed to increase the accuracy of quantification, and the percent recovery calculated for 175 ng/mL was 105.14%.  相似文献   

3.
A simple, rapid, and efficient dispersive liquid–liquid microextraction method, followed by UV–Vis spectrophotometry was developed for the preconcentration and determination of Pd ions in water samples. Pd ions react with α-furildioxime (chelating agent) to form a hydrophobic complex. Various parameters were altered to study and optimize their effects on the extraction efficiency, such as pH, ligand concentration, the type and volume of extraction and dispersive solvents, extraction time, and salt concentration. Under optimized conditions, the method exhibited an enrichment factor (C org/C aq) of 25 and recovery more than 98 % within a very short extraction time. The linearity of the method ranged from 10 to 200 μg?L?1. The limit of detection was 1.1 μg?L?1. The relative standard deviation for the concentration of 100 μg?L?1 of Pd was 2.3 % (n?=?10). Finally, the developed method was successfully applied to the extraction and determination of Pd in tap, river, mineral, and sea water samples.  相似文献   

4.
A simple and sensitive solid phase extraction (SPE) method on multiwalled carbon nanotubes (MWCNTs) is presented for the determination of cadmium, lead, nickel, copper, and zinc at trace levels combined with flame atomic absorption spectrometry. The effects of parameters like pH, sample volume, sample and eluent flow rates, eluent concentration, and volume and type of eluent on the recovery of trace elements was examined. The metals retained on the nanotube at pH 6.5 as α-benzoin oxime complexes were eluted by 10 mL 2 M HNO3 in acetone. The influence of matrix ions on the developed method was also evaluated. The preconcentration factor of the method was found to be 50. The detection limits for Cd(II), Pb(II), Ni(II), Cu(II), and Zn(II) were found as 1.7, 5.5, 6.0, 2.3, and 2.4 μg L?1, respectively. To test the accuracy of the method, the method was applied to TMDA-70 fortified lake water and Spinach 1570A standard reference materials. Addition recovery studies were applied to tap water and cracked wheat samples, and determination of the analyte elements was carried out in some food samples with good results.  相似文献   

5.
液液萃取-气相色谱法测定饮用水中硝基苯类化合物   总被引:1,自引:0,他引:1  
采用液液萃取-气相色谱法测定饮用水中10种硝基苯类化合物,通过萃取条件优化试验,选择正己烷为萃取剂,使目标物在0μg/L~38.5μg/L之间线性良好,检出限为0.002μg/L ~0.005μg/L。实际饮用水样的加标回收率为80.8%~104%,RSD<3%。用该方法测定桂林市4个水厂饮用水,结果硝基苯、间-二硝基苯、2,4-二硝基氯苯未检出,其余7种硝基苯类化合物虽有检出,但检出值均低于标准规定的限值。  相似文献   

6.
The aim of this study was the development of analytical methods for the simultaneous determination of 25 selected pharmaceuticals, metabolites, and pesticides, belonging to the various chemical classes, in river sediments and their corresponding surface and ground water with the purpose of monitoring the contamination levels. The methods were based on the solid-phase extraction as the sample preparation method for water samples, and the ultrasonic solvent extraction for the sediment samples, followed by the liquid chromatography–tandem mass spectrometry. High recoveries were achieved for extraction from both water and sediment samples for the majority of analytes. Low limits of detection were achieved for all investigated compounds in the water sample (1–5 ng L?1) as well as in the sediment (1–3 ng g?1). Applicability of the developed methods was demonstrated by determination of pharmaceutical and pesticide residues in 30 surface water, 44 groundwater, and 5 sediment samples from the Danube River Basin in Serbia. Sixty percent of target compounds were detected in environmental samples. The most frequently detected analytes in river sediments were the pesticides dimethoate and atrazine, while carbamazepine and metamizole metabolites 4-AAA and 4-FAA were the most frequently found in water samples.  相似文献   

7.
A novel improved preconcentration method known as rapidly synergistic cloud point extraction (RS-CPE) was established for nickel preconcentration and determination prior to its determination by flame atomic absorption spectrometry. In this work, the traditional CPE pattern was changed and greatly simplified in order to be applicable in metal extraction and detection. This method was accomplished in room temperature in 1 min. Non-ionic surfactant Triton X-114 was used as extractant. Octanol worked as cloud point revulsant and synergic reagent. The various parameters affecting the extraction and preconcentration of nickel such as sample pH, 2,2′-Furildioxime concentration, amounts of octanol, amounts of Triton X-114, type of diluting solvent, extraction time, and ionic strength were investigated and optimized. Under optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 2–200 μg L?1, and the limit of detection was 0.6 μg L?1 for nickel. The developed method was successfully applied for the determination of nickel in food and water samples. The results showed that, the proposed method can be used as a cheap, rapid, and efficient method for the extraction and preconcentration of nickel from real samples.  相似文献   

8.
A method for the residual pendimethalin in soil and vegetable samples was developed. The method is based on extraction of pendimethalin from samples using microwave-assisted solvent extraction (MASE) with acetone, ethanol, and water as extraction solvent. Extracted pendimethalin samples were analyzed by high-performance liquid chromatography with ultraviolet detector at 240 nm. The MASE parameters, temperature, heating time, and solvent types were optimized with the feasibility of MASE application in the determination of pendimethalin extraction efficiency of pendimethalin from soil and vegetable samples. The maximum temperature that can be used during the heating for MASE is 60°C, where the recovery percentages reached 97%. Linearity for pendimethalin was found in the range of 2?C20 ??g mL???1 with limits of detection and limits of quantification of 0.059 and 0.17 ??g mL???1, respectively.  相似文献   

9.
In this paper, a simple and sensitive spectrophotometric method for the determination of nanomolar level of bromate, based on the catalytic effect of silver nanoparticles on the oxidation of acid red 14 by potassium bromate, is described. The reaction rate was monitored spectrophotometrically by measuring the decrease in absorbance of acid red 14 at 516 nm. The detection limit of the method was 8 ng/mL, and the linear range was between 15 and 130 ng/mL. The effects of acidity, concentration of reactants and reaction time, and external ions were also discussed. The optimum reaction conditions were fixed, and some kinetic parameters determined. The relative standard deviation for the determination of bromate at the concentration of 50 ng/mL was calculated to be 0.996 % (n?=?10). The method has been successfully applied to the determination of bromate in flours and bottled waters.  相似文献   

10.
A new kinetic method has been developed for the determination of iodine in water samples. The method is based on the catalytic effect of I? with the oxidation of Indigo Carmine (IC) by KBrO3 in the sulfuric acid medium. The optimum conditions obtained are 0.16 M sulfuric acid, 1?×?10?3 M of IC, 1?×?10?2 M KBrO3, reaction temperature of 35°C, and reaction time of 80 s at 612 nm. Under the optimized conditions, the method allowed the quantification of I? in a range of 12–375 ng/mL with a detection limit of 0.46 ng/mL. The method was applied to the determination of iodine in river and city water samples with the satisfactorily results.  相似文献   

11.
A new kinetic method has been developed for the determination of nitrite in fruit juice samples. The method is based on the catalytic effect of nitrite with the oxidation of Nile Blue A (NBA) by KBrO3 in the sulfuric acid medium. The optimum conditions obtained are 1.2 mM sulfuric acid, 0.034 mM of NBA, 2.8?×?10?3 M KBrO3, reaction temperature of 20 °C, and reaction time of 100 s at 595.5 nm. Under the optimized conditions, the method allowed the quantification of nitrite in a range of 0.2–800 μg/mL with a detection limit of 0.02 μg/mL. The method was applied to the determination of nitrite in 15 brands of fruit juice samples.  相似文献   

12.
Polycyclic aromatic hydrocarbons are known for their carcinogenic and mutagenic effects on human health. This therefore calls for the regulation of their concentrations in air, water, and soil. Naphthalene as the simplest in structure of the polycyclic aromatic hydrocarbons is mainly used as a starter material for other chemicals but also has impacts on human health. A method is therefore proposed for the determination of naphthalene in water samples by gas chromatography mass spectrometry after liquid-liquid extraction. The extraction method was optimized to improve the extraction output, thereby lowering the limit of detection. The limits of detection and quantification obtained for naphthalene were 4.4 and 14.6 ng mL?1, respectively. Deuterated anthracene was used as internal standard to enhance the precision of the method, for which a relative standard deviation of 4.3% was obtained. The percent recovery of naphthalene obtained from tap water was ranged between 93.8 and 102.2.  相似文献   

13.
A simple and sensitive method based on a modified hollow-fiber liquid-phase microextraction followed by gas chromatography–mass spectrometry has been successfully developed for the extraction and simultaneous derivatization of some nitrophenols (NPs) in soil and rain samples. Microwave-assisted solvent extraction was used for the extraction of NPs from the soil, while the rain sample was directly applied to the previously mentioned method. Briefly, in this method, the analytes were extracted from aqueous samples into a thin layer of organic solvent (dodecane?+?10 % tri-n-octylphosphine oxide) sustained in the pores of a porous hollow fiber. Then, they were back-extracted using a small volume of organic acceptor solution (25 μl; 10 mg/L N-methyl-N-(trimethylsilyl)trifluoroacetamide, as derivatization reagent, in acetonitrile) that was located inside the lumen of the hollow fiber. Under the optimized extraction conditions, enrichment factors of 255 to 280 and limits of detection of 0.1 to 0.2 μg/L (S/N?=?3) with dynamic linear ranges of 1–100 μg/L were obtained for the analytes. The accuracy of the approach was tested by the relative recovery experiments on spiked samples, with results ranging from 93 to 113 %. The method was shown to be rapid, cost-effective, and potentially interesting for screening purposes.  相似文献   

14.
Highly rapid and selective vortex-assisted liquid–liquid microextraction based on solidification of organic drop has been used for determination of cobalt ion. 2-Nitroso-1-naphthol (2N1N) was used as a selective complexing agent to form stable cobalt–2N1N complex which can be extracted with 1-undecanol at a short time by the assistance of vortex agitator system followed by its determination using flame atomic absorption spectrometry. In vortex assisted, vigorous vortex stream as well as the vibrant effect of vortex system cause very fine droplets of extraction solvent to be produced and extraction occurred at a short time. Some parameters influencing the extraction process such as pH of samples, concentration of 2-nitroso-1-naphthol, extraction solvent volume, extraction time, ionic strength and surfactant addition, as well as interferences were evaluated in detail and optimum conditions were selected. At the optimum conditions, the calibration curve was linear in the range of 15 to 400 μg L?1 of cobalt ions. The relative standard deviation based on ten replicate analysis of sample solution containing 50 μg L?1 of cobalt was 3.4 %. The detection limit (calculated as the concentration equivalent to three times of the standard deviation of the blank divided by the slope of the calibration curve after preconcentration) was 5.4 μg L?1. The accuracy of the proposed method was successfully evaluated by the analysis of certified reference materials. This selective and highly rapid method was used for determination of cobalt ions in different water samples.  相似文献   

15.
This study suggested a new method for simultaneous quantification of two dyes in complex matrices using second-order data by spectrophotometry. Second-order data was generated simply without any expensive instrument using two independent variables including wavelength and the monotonic addition of sodium dodecyl sulfate. Solid-phase extraction (SPE) based on amino-rich magnetic single-walled carbon nanotube as an adsorbent was employed prior to second-order data generation. SPE optimization was performed by Box-Behnken design, and parameters and their interaction which were dependent on the simultaneous extraction of dyes were examined. Competitive Langmuir and Freundlich isotherms for a binary system and individual dyes could all represent the equilibrium data well. The second-order data was processed by parallel factor analysis (PARAFAC and PARAFAC2) and multivariate curve resolution-alternating least squares (MCR-ALS). Figures of merit of the model including a limit of detection of 3.0 and 2.5 ng mL?1 for crystal violet and malachite green, respectively, were estimated using the MCR-ALS method. The combination of the second-order calibration and SPE presents an easy and versatile method for determination of the mixture of two dyes in the presence of uncalibrated interferences in environmental water, synthetic, and fish samples with the recoveries of 94–104.  相似文献   

16.
New solid-phase extractor (MWCNTs-5-ASA) was synthesized via covalent immobilization of 5-aminsalicylic acid onto multi-walled carbon nanotubes (MWCNs). The success of the functionalization process was confirmed using Fourier transform infrared spectroscopy, scanning electron microscope, and surface coverage determination. Batch experiments were conducted as a function of pH to explore MWCNTs-5-ASA efficiency to extract several metal ions viz., Cr(III), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Pb(II). It was found that Pb(II) exhibits the highest extraction percentage with maximum adsorption capacity 32.75 mg g?1. Its binding performance was well fitted with Langmuir sorption isotherm. On the other hand, the selective separation and preconcentration of trace Pb(II) under dynamic conditions prior to determination by inductively coupled plasma-optical emission spectrometry was investigated under different parameters. These included the rate of flow and volume of sample solution, in addition to the type of the eluate, its volume and concentration. The effect of a variety of foreign ions on the recovery percentage was also evaluated. Trace Pb(II) ions present in 500 mL aqueous solution adjusted to pH 4.0 were retained on 50 mg of MWCNTs-5-ASA and completely eluted using 4.0 mL of 2 M HNO3. The limit of detection and the precision of the method were 0.25 ng mL?1 and 2.8 %, respectively (N?=?5). This methodology has been applied for the determination of Pb(II) in water samples with good results.  相似文献   

17.
A method for the determination of herbicides residues, triazine (atrazine, metribuzin, ametryn, and terbutryn), in soil samples with high-performance liquid chromatography (HPLC)?CUV detection is described. The proposed method is based on microwave-assisted extraction (MAE) of soil samples for 4 min at 80% of 850-W magnetron outputs in the presence of mixture of solvents (methanol/acetonitrile/ethylacetate). Related important factors influencing the MAE efficiency, such as the solvent type and volume, irradiation energy, and time, were optimized in detail. Calibration curve ranges established using HPLC for metribuzin, atrazine, ametryn, and terbutryn are 1.0?C19.0, 0.9?C18.0, 0.6?C11.0, and 0.7?C11.0 µg mL???1, respectively. The limits of detection of metribuzin, atrazine, ametryn, and terbutryn are 0.30, 0.24, 0.16, and 0.20 µg mL???1 while limits of quantification are 1.0, 0.80, 0.50, and 0.60 µg mL???1, respectively. A Plackett?CBurman factorial design was used as a screening method in order to select the variables that influence MAE extraction. The recoveries of the method at three different spiked levels were assessed by analyzing real soil samples and were found to be in the range of 83.33 ± 0.12?C96.33 ± 0.23 with good precision (<8%).  相似文献   

18.
The developed method is based on cold-induced aggregation microextraction of Se(IV) using the 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid as an extractant followed by spectrophotometry determination. The extraction of Se(IV) was performed in the presence of dithizone as the complexing agent. In this method, a very small amount of 1-butyl-3-methylimidazolium hexafluorophosphate was added to the sample solution containing Se-dithizone complex. Then, the solution was kept in a thermostated bath at 50 °C for 4 min. Subsequently, the solution was cooled in an ice bath and a cloudy solution was formed. After centrifuging, the extractant phase was analyzed using a spectrophotometric detection method. Some important parameters that might affect the extraction efficiency were optimized (HCl, 0.6 mol L?1; dithizone, 4.0?×?10?6 mol L?1; ionic liquid, 100 μL). Under the optimum conditions, good linear relationship, sensitivity, and reproducibility were obtained. The limit of detection (LOD) (3Sb/m) was 1.5 μg L?1, and the relative standard deviation (RSD) was 1.2 % for 30 μg L?1 of Se(IV). The linear range was obtained in the range of 5–60 μg L?1. It was satisfactory to analyze rice and various water samples.  相似文献   

19.
An analytical method for the determination of diflufenican, mepanipyrim, pretilachlor, and fipronil in water samples was developed using single drop microextraction in the direct immersion mode and gas chromatography–mass spectrometry. A factorial fractionated design of type 26–1 at two levels was performed, to study the influence of experimental variables such as ionic strength, pH, agitation speed, extraction time, drop volume, and sample volume. To establish the optimal conditions for the variables that were significant, a Doehlert design was performed. The optimum conditions of extraction were 1 μL of heptane immersed in 4.0 mL of sample with continuous agitation at 500 rpm for 30 min at room temperature. The developed method proved to have good linearity for the range studied. The detection limits were 0.07 μg L?1 for diflufenican, 0.03 μg L?1 for mepanipyrim, 0.08 μg L?1 for pretilachlor, and 1.39 μg L?1 for fipronil. The method was validated on river water samples, showing the absence of matrix effect and recoveries ranged from 90.1 to 107.8 %. The results show that the method developed is accurate, sensitive, rapid, simple, and low cost, so it is recommended for application in the analysis of these different classes of pesticides in water samples.  相似文献   

20.
A simple, rapid, and efficient sample pretreatment technique, based on solvent-based de-emulsification dispersive liquid–liquid microextraction (SD-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for simultaneous preconcentration and trace detection of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in water and urine samples. Some parameters such as acidity of solution, the amount of salt, type, and volume of extraction solvents, type of disperser/de-emulsifier solvent, and its volume were investigated and optimized. Under optimum extraction conditions, the limits of detections (LODs) of this method for MCPA and 2,4-D were 0.2 and 0.6 μg L?1 (based on 3Sb/m) in water and 0.4 and 1.6 μg L?1 in urine, respectively. Furthermore, dynamic linear range of this method for MCPA and 2,4-D was 1–300 and 2–400 μg L?1, repectively. Finally, the applicability of the proposed method was evaluated by extraction and determination of the herbicides in urine and different water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号