首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A Before‐ After Control‐ Impact Paired (BACIP) model was used to evaluate the effectiveness of phytoremediation treatment on reduction of bentazon concentrations in shallow groundwater at a study site in Louisiana. Two different statistical approaches were made to evaluate the impact to this test site from the remediation program through time. Data were evaluated by Bayesian analysis of variance test methods. Data sets were unique in that the control data used for impact evaluation, as compared to before and after data, were compiled from groundwater upgradient monitoring wells existing prior to remediation. The statistical model supports the hypothesis that the phytoremediation program has positively impacted groundwater at the study site. © 2006 Wiley Periodicals, Inc.  相似文献   

2.
In situ remediation represents a series of challenges in interpreting the monitoring data on remedial progress. Among these challenges are problems in determining the progress of the remediation and the mechanisms responsible, so that the process can be optimized. The release of organic pollutants to groundwater systems and in situ remediation technologies alter the groundwater chemistry, but outside of natural attenuation studies using inorganic chemical analyses as indicators of intrinsic biodegradation, typically little attention has been paid to the changes in inorganic groundwater chemistry. Smith (2008) noted that during an electrical resistance heating remediation that took place at a confidential site in Chicago, a two‐orders‐of‐magnitude increase in chloride concentrations occurred during the remediation. This increase in chloride resulted in a corresponding increase in calcium as a result of what is known as the common ion effect. Carbon dioxide is the gas found in highest concentrations in natural groundwater (Stumm & Morgan, 1981), and its fugacity (partial pressure) corresponds directly with calcium concentrations. Carbon dioxide at supersaturation in groundwater is capable of dissolving organic compounds, such as trichloroethene, facilitating removal of nonaqueous‐phase liquids at temperatures below the boiling point of water. One means of diagnosing these reactions is through the use of compound‐specific isotopic analysis, which is capable of distinguishing between evaporation, biodegradation, and differences in sources. The appropriate diagnosis has the potential to optimize the benefits from these reactions, lower energy costs for removal of nonaqueous‐phase liquids, and direct treatment where it is needed most. © 2010 Wiley Periodicals, Inc.  相似文献   

3.
Laboratory and field demonstration studies were conducted to assess the efficacy of enhanced biological reduction of 1,2,3‐trichloropropane (TCP) in groundwater. Laboratory studies evaluated the effects of pH and initial TCP concentrations on TCP reduction and the activity of a microbial inoculum containing Dehalogenimonas (Dhg). Laboratory results showed successful reduction at a pH of 5 to 9 with optimal reduction at 7 to 9 and at initial TCP concentrations ranging from 10 to over 10,000 micrograms per liter (μg/L). Based on findings from the laboratory study, the effects of TCP concentration, geochemical conditions, and amendment concentration on bioremediation efficacy were investigated during a field demonstration at a site with relatively low initial concentrations of TCP (< 2 μg/L). The field demonstration included injection of emulsified vegetable oil (EVO) and lactate as a carbon substrate for biostimulation, followed by bioaugmentation using the microbial inoculum containing Dhg. Post‐injection performance monitoring demonstrated reduction of TCP to below laboratory detection limits (< 0.005 μg/L) after an initial lag period of approximately six months following injections. TCP reduction was accompanied by generation of the degradation byproduct propene. A marginal increase in TCP concentrations, potentially due to an influx of upgradient aerobic groundwater containing TCP, was observed eight months after injections thereby demonstrating the sensitivity of this bioaugmentation application to changes in geochemical parameters. Despite this marginal increase, performance monitoring results indicate continued TCP biodegradation 15 months after implementation of the injection program. This demonstration suggests that enhanced biodegradation of TCP by combining biostimulation and bioaugmentation may be a promising solution to the challenges associated with remediation of TCP, even when present at low part per billion concentrations in groundwater.  相似文献   

4.
Per‐ and polyfluoroalkyl substances (PFAS) are highly resistant to biotic and abiotic degradation and can withstand very high temperatures before breaking down. The storage of PFAS‐impacted water and sediments in a holding pond or stockpiled investigation or remedial action‐derived waste is occurring on an increasing number of sites. The most common PFAS water treatment options include granular‐activated carbon and resins and the most common soil treatment options have been primarily limited to excavation, offsite incineration, and, in some cases, soil stabilization. An increasing number of states across the United States are establishing part per trillion PFAS guidance levels for drinking water. Removing PFAS from soils removes PFAS source impacts to groundwater. In this study, volatilization of PFAS from soil treated using in situ thermal heating is evaluated as a treatment method to achieve a high degree of PFAS removal from soils. The evaluation of temperatures needed to achieve removal is described. To minimize vapor treatment required for PFAS thermal remediation, a scrubber was incorporated into the treatment train to transfer PFAS to the liquid phase in a concentrated, low‐volume solution. Vapor‐liquid equilibrium behavior and the extent of PFAS volatilization from impacted soil over a range of temperatures were evaluated. Results showed that heating soil to 350°C and 400°C reduces PFAS soil concentrations by 99.91% and 99.998%, respectively. It was also confirmed that sulfonate‐based PFAS generally required higher temperatures for volatilization to occur than carboxylate‐based PFAS.  相似文献   

5.
A field demonstration of a mulch permeable reactive barrier (PRB), or “biowall,” as an in situ treatment technology for explosives in groundwater is summarized. Organic mulch consists of insoluble carbon biopolymers that are enzymatically hydrolyzed during decomposition to release aqueous total organic carbon (TOC). The released TOC is then available for microorganisms to use as an electron donor to transform electrophilic contaminants via reductive pathways. A 100‐foot‐long and 2‐foot‐thick mulch biowall was installed at the Pueblo Chemical Army Depot in Colorado to treat a shallow groundwater plume containing hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX). To discourage groundwater flow bypassing around and under the biowall in this highly permeable formation, a hydraulic control was installed and the PRB was keyed into the bedrock. Technology performance was monitored using a monitoring well network to establish the development and extent of the downgradient treatment zone. Performance objectives of the field demonstration were: (1) greater than 90 percent removal of RDX across the PRB and the treatment zone; (2) an RDX concentration of less than 0.55 μg/L in the treatment zone; and (3) cumulative toxic intermediate concentration (nitroso intermediates of RDX, MNX, DNX, and TNX) of less than 20 percent of the upgradient RDX concentration. All performance objectives were met within seven months after installation once the system reached a pseudo‐steady state. By this point, a sustained reducing/treatment zone had been created downgradient of the mulch PRB that showed greater than 93 percent RDX removal, RDX concentrations less than 0.55 μg/L, and no accumulation of toxic intermediates. The mulch biowall implemented during this demonstration was successful at meeting performance objectives while addressing the majority of potential concerns of the technology. © 2009 Wiley Periodicals, Inc.  相似文献   

6.
Permeable barriers are structures installed in situ to treat contaminated groundwater. Pollutants are removed as contaminated groundwater flows through a barrier material. A compost/sand barrier and a plant covered permeable barrier with soil/sand and peat/sand were tested in pilot-scale to treat creosote-contaminated groundwater by sorption and biological removal in situ. Outlet concentrations of the barriers were consistently low during the 29 months of operation. Although sorption sites were filled up with polycyclic aromatic hydrocarbons, they seemed to be regenerated because of biodegradation under aerobic conditions. The vegetated section was least efficient, probably because of lack of oxygen, hence it could not be determined if the plants had a positive effect. As long as biodegradation is efficient the barrier is expected to function for several more years.  相似文献   

7.
A series of laboratory microcosm experiments and a field pilot test were performed to evaluate the potential for aerobic biodegradation of aromatic hydrocarbons and methyl tert‐butyl ether (MtBE; a common oxygenate additive in gasoline) in saline, high temperature (>30° C) groundwater. Aquifer, sediment, and groundwater samples from two sites, one in Canada and another in Saudi Arabia, were incubated for 106 days to evaluate the changes in select hydrocarbon and MtBE concentrations and microbial community structure. Almost complete biodegradation of the aromatic hydrocarbons was found in the Saudi Arabian microcosm samples whereas the Canadian microcosm samples showed no significant biodegradation during the laboratory testing. MtBE degradation was not observed in either set of microcosms. Denaturing gradient gel electrophoresis analyses showed that, while the Canadian microorganisms were the most diverse, they showed little response during incubation. The microbial communities for the Saudi Arabian sample contained significant numbers of microorganisms capable of hydrocarbon degradation which increased during incubation. Based on the laboratory results, pilot‐scale testing at the Saudi Arabian field site was carried out to evaluate the effectiveness of enhanced aerobic biodegradation on a high temperature, saline petroleum hydrocarbon plume. Dissolved oxygen was delivered to the subsurface using a series of oxygen diffusion emitters installed perpendicular to groundwater flow, which created a reactive zone. Results obtained from the seven‐month field trial indicated that all the target compounds decreased with removal percentages varying between 33 percent for the trimethylbenzenes to greater than 80 percent for the BTEX compounds. MtBE decreased 40 percent on average whereas naphthalene was reduced 85 percent on average. Examination of the microbial population upgradient and downgradient of the emitter reactive zone suggested that the bacteria population went from an anaerobic, sulfate‐reducing dominated population to one dominated by a heterotrophic aerobic bacteria dominant population. These studies illustrate that field aerobic biodegradation may exceed expectations derived from simple laboratory microcosm experiments. Also, high salinity and elevated groundwater temperature do not appear to inhibit in situ aerobic biorestoration. © 2014 Wiley Periodicals, Inc.  相似文献   

8.
Permeable reactive barriers made of zero‐valent iron (ZVI PRBs) have become a prominent remediation technology in addressing groundwater contamination by chlorinated solvents. Many ZVI PRBs have been installed across the United States, some as research projects, some at the pilot scale, and many at full scale. As a passive and in situ remediation technology, ZVI PRBs have many attractive features and advantages over other approaches to groundwater remediation. Ten ZVI PRBs installed in California were evaluated for their performance. Of those ten, three are discussed in greater detail to illustrate the complexities that arise when quantifying the performance of ZVI PRBs, and to provide comment on the national debate concerning the downgradient effects of source‐zone removal or treatment on plumes of contaminated groundwater. © 2009 Wiley Periodicals, Inc.  相似文献   

9.
In June and July 2001, the Massachusetts Department of Environmental Protection (MassDEP) installed a permeable reactive barrier (PRB) to treat a groundwater plume of chlorinated solvents migrating from an electronics manufacturer in Needham, Massachusetts, toward the Town of Wellesley's Rosemary Valley wellfield. The primary contaminant of concern at the site is trichloroethene (TCE), which at the time had a maximum average concentration of approximately 300 micrograms per liter directly upgradient of the PRB. The PRB is composed of a mix of granular zero‐valent iron (ZVI) filings and sand with a pure‐iron thickness design along its length between 0.5 and 1.7 feet. The PRB was designed to intercept the entire overburden plume; a previous study had indicated that the contaminant flux in the bedrock was negligible. Groundwater samples have been collected from monitoring wells upgradient and downgradient of the PRB on a quarterly basis since installation of the PRB. Inorganic parameters, such as oxidation/reduction potential, dissolved oxygen, and pH, are also measured to determine stabilization during the sampling process. Review of the analytical data indicates that the PRB is significantly reducing TCE concentrations along its length. However, in two discrete locations, TCE concentrations show little decrease in the downgradient monitoring wells, particularly in the deep overburden. Data available for review include the organic and inorganic analytical data, slug test results from nearby bedrock and overburden wells, and upgradient and downgradient groundwater‐level information. These data aid in refining the conceptual site model for the PRB, evaluating its performance, and provide clues as to the reasons for the PRB's underperformance in certain locations. © 2008 Wiley Periodicals, Inc.  相似文献   

10.
Conventional methods to estimate groundwater velocity that rely on Darcy's Law and average hydrogeologic parameter values are insensitive to local‐scale heterogeneities and anisotropy that control advective flow velocity and direction. Furthermore, at sites that are tidally influenced or have extraction wells with variable pumping schedules, infrequent water‐level measurements may not adequately characterize the range and significance of transient hydraulic conditions. The point velocity probe (PVP) is a recently developed instrument capable of directly measuring local‐scale groundwater flow velocity and direction. In particular, PVPs may offer distinct advantages for sites with complex groundwater–surface water interactions and/or with spatially and temporally variable groundwater flow conditions. The PVP utilizes a small volume of saline tracer and inexpensive sensors to directly measure groundwater flow direction and velocity in situ at the centimeter‐scale and discrete times. The probes are installed in conventional direct‐push borings, rather than in wells, thus minimizing the changes and biases in the local flow field caused by well installation and construction. Six PVPs were installed at a tidally influenced site in North Carolina to evaluate their implementability, performance, and potential value as a new site characterization tool. For this study, a new PVP prototype was developed using a rapid prototyping machine (i.e., a “three‐dimensional printer'') and included both horizontally and vertically oriented tracer detectors. A site‐specific testing protocol was developed to account for the spatially and temporally variable hydraulic conditions and groundwater salinity. The PVPs were tested multiple times, and the results were compared to the results of several different groundwater flux and velocity estimation tools and methods, including a heat‐pulse flowmeter, passive flux meters, single‐well tracer tests, and high‐resolution hydraulic gradient analysis. Overall, the results confirmed that the PVP concept is valid and demonstrated that reliable estimates of groundwater velocity and direction can be obtained in simple settings. Also, PVPs can be successfully installed by conventional methods at sites where the formation consists primarily of noncohesive soils and the water table is relatively shallow. Although some PVP tests yielded consistent and reliable results, several tests did not. This is likely due to the highly transient flow conditions and limitations associated with the PVP design and testing procedures. PVPs offer particular advantages over, and can effectively complement, other groundwater flow characterization techniques for certain conditions, and objectives may be useful for characterizing complex flow patterns under steady conditions; however, this study suggests that PVPs are best suited for conditions where the flow hydraulics are not highly transient. For sites where the hydraulic conditions are highly transient, the most reliable approach for understanding groundwater flow behavior and groundwater–surface water interactions would generally involve both a high‐resolution hydraulic gradient analysis and another local‐scale method, such as tracer testing. This study also highlighted some aspects of the current PVP design and testing protocol that can be improved upon, including a more robust connection between the PVP and injection line and further assessment of tracer solution density effects on vertical flow. © 2013 Wiley Periodicals, Inc.  相似文献   

11.
In a pilot test experiment involving approximately 200,000 gallons of groundwater, Electrochemical Peroxidation (ECP) was used to degrade aqueous phase volatile organic compounds (VOCs) including benzene, toluene, ethylbenzene, and xylene (BTEX) compounds and methyl tertbutyl ether (MTBE) from a petroleum spill. ECP involves a form of the Fenton's Reagent reaction, which uses electrochemically generated iron and dilute hydrogen peroxide (<30 mg/L) to break down organic molecules through oxidation to carbon dioxide and water. This article discusses a pilot scale demonstration of the ECP technology and its application to aqueous phase organic contaminants. The remedial approach used at the pilot test site involves three phases: (1) ex‐situ chemical oxidation, (2) in‐situ oxidation by reinjection of treated effluent near the plume origin, and (3) reestablishment of aerobic biodegradation as the residual hydrogen peroxide discharged to a series of upgradient wells degrades to oxygen. Analytical results of the pilot demonstration indicate that the ex‐situ chemical oxidation reduced total BTEX concentrations in groundwater from over 1,000 ppb to undetectable concentrations (<1 ppb). © 2000 John Wiley & Sons, Inc.  相似文献   

12.
Remediation of a large separate‐phase hydrocarbon product and associated dissolved‐phase gasoline plume was accelerated by coupling multiphase extraction with in situ microbial stimulation. At the beginning of remediation activities, the separate‐phase hydrocarbon plume extended an estimated seven acres with product thickness measuring up to 2.1 feet thick. Within 18 months after beginning extraction, reduction of gasoline constituents in groundwater became asymptotic and measureable product disappeared from the upgradient source area. At that time, the remediation team initiated a program of limited in situ anaerobic bioremediation with the goal of stimulating production of natural surfactants from native microbes to release petroleum from the soil matrix. Groundwater concentrations of gasoline constituents increased gradually over the next three years, improving recovery without biofouling the pump‐and‐treat infrastructure. Using this approach, the groundwater component of the remedy was completed in less than five years, substantially less than the 10 years to 15 years predicted by modeling. This strategy demonstrated a more sustainable approach to remediation, reducing electrical usage by an estimated 800 megawatt hours, reducing infrastructure requirements, and preserving an estimated 150 million gallons of groundwater for this arid agricultural area. © 2014 Wiley Periodicals, Inc.  相似文献   

13.
A new in situ remediation concept termed a Horizontal Reactive Media Treatment Well (HRX Well®) is presented that utilizes a horizontal well filled with reactive media to passively treat contaminated groundwater in situ. The approach involves the use of a large‐diameter directionally drilled horizontal well filled with solid reactive media installed parallel to the direction of groundwater flow. The engineered contrast in hydraulic conductivity between the high in‐well reactive media and the ambient aquifer hydraulic conductivity results in the passive capture, treatment, and discharge back to the aquifer of proportionally large volumes of groundwater. Capture and treatment widths of up to tens of feet can be achieved for many aquifer settings, and reductions in downgradient concentrations and contaminant mass flux are nearly immediate. Many different types of solid‐phase reactive treatment media are already available (zero valent iron, granular activated carbon, biodegradable particulate organic matter, slow‐release oxidants, ion exchange resins, zeolite, apatite, etc.). Therefore, this concept could be used to address a wide range of contaminants. Laboratory and pilot‐scale test results and numerical flow and transport model simulations are presented that validate the concept. The HRX Well can access contaminants not accessible by conventional vertical drilling and requires no aboveground treatment or footprint and requires limited ongoing maintenance. A focused feasibility evaluation and alternatives analysis highlights the potential cost and sustainability advantages of the HRX Well compared to groundwater extraction and treatment systems or funnel and gate permeable reactive barrier technologies for long‐term plume treatment. This paper also presents considerations for design and implementation for a planned upcoming field installation.  相似文献   

14.
Chlorinated solvents such as tetrachloroethene (perchloroethene, PCE) and trichloroethene (TCE) have been extensively used in various industrial applications for many years. Because neither are typically consumed through their various uses, they are often released to the environment through industrial application or disposal. Once released, PCE and TCE tend to migrate downward into groundwater, where they persist. In the current case study, cheese whey was used as a groundwater amendment to facilitate the reductive dechlorination of a chlorinated solvent plume underlying an auto dealer/repair shop in Harris County, Texas. From September 2010 to January 2014, over 32,000 gallons of cheese whey were injected into the subsurface resulting in a marked reduction in oxidation–reduction potential (ORP) and nitrate concentrations, coupled with an increase in ferrous iron concentrations. Statistical trend analyses indicate the primary contaminants, PCE and TCE, as well as the daughter product cis‐1,2‐dichloroethene (cDCE), all exhibited a positive response, as evidenced by statistically decreasing trends, and/or reversal in concentration trends, subsequent to cheese whey injections. Maximum concentrations of PCE and TCE in key test wells decreased by as much as 98.97 percent and 99.17 percent, respectively. In addition, the bacterial genus Dehalococcoides, capable of complete reduction of PCE to non‐toxic ethene, was found to be more abundant in the treatment area, as compared to background concentrations. Because cheese whey is a by‐product of the cheese making process, the cost of the product is essentially limited to transport. This study demonstrates cheese whey to be an effective groundwater amendment at a cost which is orders of magnitude lower than popular industry alternatives.  相似文献   

15.
Electrical resistance heating (ERH) is an in situ treatment for soil and groundwater remediation that can reduce the time to clean up volatile organic compounds (VOCs) from years to months. The technology is now mature enough to provide site owners with both performance and financial certainty in their site‐closure process. The ability of the technology to remediate soil and groundwater impacted by chlorinated solvents and petroleum hydrocarbons regardless of lithology proves to be beneficial over conventional in situ technologies that are dependent on advective flow. These conventional technologies include: soil vapor recovery, air sparging, and pumpand‐treat, or the delivery of fluids to the subsurface such as chemical oxidization and bioremediation. The technology is very tolerant of subsurface heterogeneities and actually performs as well in low‐permeability silts and clay as in higher‐ permeability sands and gravels. ERH is often implemented around and under buildings and public access areas without upsetting normal business operations. ERH may also be combined with other treatment technologies to optimize and enhance their performance. This article describes how the technology was developed, how it works, and provides two case studies where ERH was used to remediate complex lithologies. © 2005 Wiley Periodicals, Inc.  相似文献   

16.
Residual tetrachloroethene (PCE) contamination at the former Springvilla Dry Cleaners site in Springfield, Oregon, posed a potential risk through the vapor intrusion, direct contact, and off‐site beneficial groundwater uses. The Oregon Department of Environmental Quality utilized the State Dry Cleaner Program funds to help mitigate the risks posed by residual contamination. After delineation activities were complete, the source‐area soils were excavated and treated on‐site with ex situ vapor extraction to reduce disposal costs. Residual source‐area contamination was then chemically oxidized using sodium permanganate. Dissolved‐phase contamination was subsequently addressed with in situ enhanced reductive dechlorination (ERD). ERD achieved treatment goals across more than 4 million gallons of aquifer impacted with PCE concentrations up to 7,800 micrograms per liter prior to remedial activities. The ERD remedy introduced electron donors and nutrient amendments through groundwater recirculation and slug injection across two aquifers over the course of 24 months. Adaptive and mass‐targeted strategies reduced total remedy costs to approximately $18 per ton within the treatment areas. © 2010 Wiley Periodicals, Inc.  相似文献   

17.
Contaminated groundwater at a chemical antioxidant and phenolic resin chemical production site was subjected to treatability studies to develop design criteria for surface water discharge. Raw groundwater required pretreatment for total suspended solids (TSS) and color removal prior to treatment by ultraviolet light/hydrogen peroxide (UV/H2O2). Because of high capital and operating costs for UV/H2O2, biological treatment was evaluated as an alternate. Respirometric analyses showed that completely mixed activated sludge could be applied as a treatment technology to the groundwater. Biotreatment resulted in an approximately 70 percent reduction in soluble chemical oxygen demand (SCOD). Residual SCOD was recalcitrant to further biodegradation. The treated effluent was tested for aquatic toxicity using fathead minnows (Pimephales promelas) and Ceriodaphnia dubia and was found to be toxic. Toxicity reduction of biotreatment effluent was evaluated in bench-scale experiments using activated carbon adsorption, filtration, and UV/H2O2. Subsequent toxicity testing showed that filtration alone could reduce the bioeffluent toxicity and that residual SCOD was not the primary source of toxicity.  相似文献   

18.
EOS, or emulsified oil substrate, was used to stimulate anaerobic biodegradation of trichloroethene (TCE) and tetrachloroethene (PCE) at a former Army‐owned manufacturing facility located in the Piedmont area of North Carolina. Previous use of chlorinated solvents at the facility resulted in soil and groundwater impacts. Ten years of active remediation utilizing soil vacuum extraction and air sparging (SVE/AS) were largely ineffective in reducing the TCE/PCE plume. In 2002, the Army authorized preparation of an amended Remedial Action Plan (RAP) to evaluate in situ bioremediation methods to remediate TCE in groundwater. The RAP evaluated eight groundwater remediation technologies and recommended EOS as the preferred bioremediation alternative for the site. Eight wells were drilled within the 100 × 100 feet area believed to be the primary source area for the TCE plume. In a first injection phase, dilute EOS emulsion was injected into half of the wells. Distribution of the carbon substrate through the treatment zone was enhanced by pumping the four wells that were not injected and recirculating the extracted water through the injection wells. The process was repeated in a second phase that reversed the injection/extraction well pairs. Overall, 18,480 pounds of EOS were injected and 163,000 gallons of water were recirculated through the source area. Anaerobic groundwater conditions were observed shortly after injection with a corresponding decrease in both PCE and TCE concentrations. Dissolved oxygen, oxidation‐reduction potential, and sulfate concentrations also decreased after injection, while TCE‐degradation products, ferrous iron, and methane concentrations increased. The reduction in TCE allowed the Army to meet the groundwater remediation goals for the site. Approximately 18 months after injection, eight wells were innoculated with a commercially prepared dechlorinating culture (KB‐1) in an attempt to address lingering cis‐1,2‐dichloroethene (cis‐DCE) and vinyl chloride (VC) that continued to be observed in some wells. Dehalococcoides populations increased slightly post‐bioaugmentation. Both cis‐DCE and VC continue to slowly decrease. © 2007 Wiley Periodicals, Inc.  相似文献   

19.
Numerical models were used to simulate alternative funnel‐and‐gate groundwater remediation structures near property corners in hypothetical homogeneous and heterogeneous unconfined aquifers. Each structure comprised a highly permeable central gate (hydraulic conductivity = 25 m/d) and soil‐bentonite slurry walls (hydraulic conductivity = 0.00009 m/d). Gates were perpendicular to regional groundwater flow and approximately 5 m from a contaminant plume's leading tip. Funnel segments collinear to the central gate reached property boundaries; additional funnel segments followed property boundaries in the most hydraulically upgradient direction. Structures were 1 m thick and anchored into the base of the aquifer. Two structures were simulated for each aquifer: one with a 3.0‐m‐long central gate and funnels on either side; and a second with a 1.5‐m‐long central gate, funnels on either side, and 0.75‐m‐long end gates. Funnels were lengthened in successive simulations, until a structure contained a contaminant plume. Results suggest that, for the same total gate length, one‐gate structures may facilitate more rapid remediation, up to 44 percent less time in trials conducted in this study, than multiple‐gate structures constructed near property corners. However, in order to effectively contain a plume, one‐gate structures were up to 46 percent larger than multiple‐gate structures. © 2011 Wiley Periodicals, Inc.  相似文献   

20.
Over the past 10 years, there has been an increased recognition that matrix diffusion processes are a significant factor controlling the success of groundwater remediation. New field techniques and modeling tools have, consequently, been developed to understand how contaminants diffuse into and then out of low‐permeability (“low‐k”) zones and assess the resulting impact on groundwater quality. Matrix diffusion, in turn, is driven by one key factor: geologic heterogeneity. The importance of heterogeneity is being emphasized in the groundwater field by general rules of thumb such as “90% of the mass flux occurs in 10%‐20% of the cross‐sectional area” and conceptual models that show most of the groundwater flow occurs through the aquifer's “mobile porosity” which just a small fraction of commonly used effective porosity values (between 0.02 and 0.10 for mobile porosity vs. 0.25 for effective porosity). For this study, 141 boring logs from 43 groundwater remediation sites were evaluated to develop an empirically based estimate of the groundwater flow versus aquifer cross‐sectional area to confirm or reject the general flow versus area rules of thumb. This study indicated that at these 43 sites, an average of 30% of the cross‐sectional area carried 90% of the groundwater flow. Our flow‐only analysis does provide moderate (but not confirmatory) support for the “mobile porosity” concept with an estimated representative mobile porosity value of about 0.11 at the 43 sites.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号