首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Monitoring air quality in large urban agglomerations is the key to the prevention of air pollution-related problems in emerging mega-cities. The city of Wuhan is a highly industrialised city with >9 million inhabitants in Central China. Simultaneous PM10 sampling was performed during 1 year at one urban and one industrial site. Mean PM10 daily levels (156 microg m(-3) at the urban site and 197 microg m(-3) at the industrial hotspot) exceed the US-EPA or EU annual limit values by 3-4 times. A detailed study of daily speciation showed that the mean chemical composition of PM10 presents minimal differences between peak and low PM episodes. This implies that PM10 aerosols in the study area result from local emissions, and air quality management and abatement strategies in Wuhan should thus focus on local anthropogenic sources. The levels of some elements of environmental concern are relatively high (409-615 ngPb m(-3), 66-70 ngAs m(-3), 116-227 ngMn m(-3), 10-12 ngCd m(-3)) due to industrial, but also urban emissions. Principal component analysis identified a mineral source (probably cement and steel manufacture) and smelting as the main contributors to PM10 levels at the industrial site (34%), followed by a coal fired power plant (20%) and the anthropogenic regional background (16%). At the urban site the major PM10 source is a mixed coal combustion source (31%), followed by the anthropogenic regional background (28%) and traffic (16%).  相似文献   

2.
This paper presents monitoring results of daily brick kiln stack emission and the derived emission factors. Emission of individual air pollutant varied significantly during a firing batch (7 days) and between kilns. Average emission factors per 1,000 bricks were 6.35–12.3 kg of CO, 0.52–5.9 kg of SO2 and 0.64–1.4 kg of particulate matter (PM). PM emission size distribution in the stack plume was determined using a modified cascade impactor. Obtained emission factors and PM size distribution data were used in simulation study using the Industrial Source Complex Short-Term (ISCST3) dispersion model. The model performance was successfully evaluated for the local conditions using the simultaneous ambient monitoring data in 2006 and 2007. SO2 was the most critical pollutant, exceeding the hourly National Ambient Air Quality Standards over 63 km2 out of the 100-km2 modelled domain in the base case. Impacts of different emission scenarios on the ambient air quality (SO2, PM, CO, PM dry deposition flux) were assessed.  相似文献   

3.
Mass Concentration of ambient particulate matter with an aerodynamic diameter less than 10µm (PM10) are reported for the first time for a range of sites in Dublin City over a 6 month period from January 1st 1996 to June 30th 1996. PM10 gravimetric mass concentration measurements are made with low flow Partisol 2000 air samplers using an impaction type PM10 inlet and 47mm diameter glass fibre filters. In addition, much finer time resolution measurements (minimum sampling frequency of 30 minutes) are made using a tapered element oscillating microbalance (TEOM) PM10 mass monitor. These PM10 mass concentrations methods are also compared with mass concentration inferred using the standard black smoke method. Analysis of the ambient mass concentration data with reference to traffic density and meteorological influences are presented. Results for the first six months of 1996 show that the average PM10 values range from a high of 49 µg m-3 at the Dublin city centre site to 14 µg m-3 at one of the suburban sites. Intercomparison between PM10 and black smoke mass concentrations show that the relationship is site specific. Statistical analysis between PM10 levels and car traffic number show a positive correlation while a weak negative correlation is found between PM10 levels and rainfall amount, wind speed and air temperature.  相似文献   

4.
The particulate matter with an aerodynamic diameter less than or equal to 10 and 2.5 microns respectively (PM10 and PM2.5) constitutes one of the main air pollutants, which is currently regulated in Europe through Directive 2008/50/EC due to its proven harmful effects on human health. In this paper, the airborne PM10 samples collected in Zaragoza city during 2001-2009 were apportioned by statistical tools based on principal component analysis with absolute principal component scores (PCA-APCS). PM10 samples were characterized regarding their concentrations of polycyclic aromatic hydrocarbons (PAH) and water-soluble ions. PAH were analyzed by gas chromatography-mass spectrometry-mass spectrometry detection (GC-MS-MS) and ions were analyzed by ion chromatography. A total of five factors were identified by PCA-APCS corresponding to different anthropogenic and natural sources. This work was focused on analyzing in more detail those samples involving higher negative impact on human health, in particular, PM10 samples exceeding the daily PM10 limit value of 50 μg m(-3) according to Directive 2008/50/EC and samples with concentrations of benzo[a]pyrene (BaP) higher than the upper assessment threshold (BaP > 0.6 ng m(-3)) established by the Directive 2004/107/EC. Most of the exceedances of the daily PM10 limit value were associated with direct and indirect North-African long-range transport. During these exceedances, it was observed that anthropogenic pollution sources slightly decreased with regard to the natural sources. This indicated that episodes of high PM10 could have a natural origin associated with long-range transport from the African continent. On the contrary, those exceedances with regional contribution and samples with BaP concentrations higher than 0.6 ng m(-3) showed an important contribution of anthropogenic pollution sources increasing their negative impact on human health.  相似文献   

5.
鞍山市环境空气颗粒物中重金属元素分布特征   总被引:7,自引:4,他引:3  
研究了鞍山市环境空气中可吸入颗粒物(PM10和PM2.5)中重金属元素分布特征,结果表明鞍山市环境空气可吸入颗粒物中Zn、Pb、Al、Cu四种金属总和所占21种元素比例近85%。重金属元素在不同粒径颗粒物中的浓度水平有明显差别,更易富集在细颗粒物PM2.5上。  相似文献   

6.
As users of indoor climbing gyms are exposed to high concentrations (PM(10) up to 4000 μg m(-3); PM(2.5) up to 500 μg m(-3)) of hydrated magnesium carbonate hydroxide (magnesia alba), reduction strategies have to be developed. In the present paper, the influence of the use of different kinds of magnesia alba on dust concentrations is investigated. Mass concentrations, number concentrations and size distributions of particles in indoor climbing gyms were determined with an optical particle counter, a synchronized, hybrid ambient real-time particulate monitor and an electrical aerosol spectrometer. PM(10) obtained with these three different techniques generally agreed within 25%. Seven different situations of magnesia alba usage were studied under controlled climbing activities. The use of a suspension of magnesia alba in ethanol (liquid chalk) leads to similar low mass concentrations as the prohibition of magnesia alba. Thus, liquid chalk appears to be a low-budget option to reduce dust concentrations. Magnesia alba pressed into blocks, used as powder or sieved to 2-4 mm diameter, does not lead to significant reduction of the dust concentrations. The same is true for chalk balls (powder enclosed in a sack of porous mesh material). The promotion of this kind of magnesia alba as a means of exposure reduction (as seen in many climbing gyms) is not supported by our results. Particle number concentrations are not influenced by the different kinds of magnesia alba used. The particle size distributions show that the use of magnesia alba predominantly leads to emission of particles with diameters above 1 μm.  相似文献   

7.
Size fractionated particulate matter (PM) was collected in summer and winter from Beijing, China for the characterization of an expanded list of PAHs and evaluation of air pollution metrics. Summertime ΣPAHs on PM was 14.6 ± 29(PM 1.5), 0.88 ± 0.49(PM 1.5-7.2) and 0.29 ± 0.076(PM 7.2) ng m(-3) air while wintertime concentrations were 493 ± 206(PM 1.5), 26.7 ± 14(PM 1.5-7.2) and 5.3 ± 2.5(PM 7.2) ng m(-3) air. Greater than 90% of the carcinogenic PAHs were concentrated on PM(1.5). Dibenzopyrene isomers made up a significant portion (~30%) of the total carcinogenic PAH load during the winter. To our knowledge, this is the first report of dibenzopyrenes in the Beijing atmosphere and among the few studies that report these highly potent PAHs in ambient particulate matter. Lifetime risk calculations indicated that 1 out of 10,000 to over 6 out of 100 Beijing residents may have an increased risk of lung cancer due to PAH concentration. Over half of the lifetime risk was attributed to Σdibenzopyrenes. The World Health Organization and Chinese daily PM(10) standard was exceeded on each day of the study, however, PAH limits were only exceeded during the winter. The outcomes of the air pollution metrics were highly dependent on the individual PAHs measured and seasonal variation.  相似文献   

8.
2019年10月12日—11月25日,使用单颗粒气溶胶飞行时间质谱仪(SPAMS)在位于长沙市的湖南省生态环境厅点位进行了为期45 d的定点监测。结果表明,监测期间长沙市总体空气质量小时级别优、良天气占比为80.3%。长沙市首要污染物为PM_(2.5),其主要来源为机动车尾气源,二次无机源次之,工业工艺源排在第三位,占比分别为27.4%,21.5%和17.4%。整体来看,监测期间PM_(2.5)质量浓度的升高大多伴随着以上3种污染源颗粒物的同步升高。机动车尾气源具有明显的早高峰,工业工艺源、生物质燃烧源和餐饮源夜间占比增加。在偏东方向气团主导下,工业工艺源和燃煤源贡献最大;在东北方向气团主导下,PM_(2.5)质量浓度最高,且机动车尾气源占比最高。  相似文献   

9.
Spatiotemporal characteristics and impact of ambient air-quality attributed to open burning of rice straw were analyzed and estimated with measured data. Two multivariate analytic methods, factor analysis and cluster analysis, were adopted to analyze the temporal and spatial impact on ambient air-quality during the rice straw burning episode. Temporal features of three scenarios were cited to compare the concentrations for ambient air-quality between the rice straw burning episode and non-episodes over two typical stations by factor analysis. Factor analysis demonstrated that the first rotational component, identified as being highly correlated to the open burning of rice straw, accounts for about 40% of the concentration variance for ambient air-quality. In typical air-quality stations, the average hourly incremental concentrations between the episode and non-episodes were greater than 300 μg m(-3) for PM(10), 1.0 ppm for CO and 35 ppb for NO(2) during the impact of rice straw burning. Factor analysis presented that the first rotated component was highly correlated with several primary pollutants (NO(2), NMHC, PM(10) and CO) during the rice straw burning episode, while every component was only highly correlated with a unique air pollutant during non-episodes. The delineation isopleths indicated that factor analysis could serve as a better method than cluster analysis and provides cross-county cooperation for local governments located in the same separated district during the rice straw burning season. The results of factor analysis revealed that CO is the best index to demonstrate the impact of rice straw burning than the other six air pollutants measured during the episode. Backward trajectory analysis supplied a cause-effect relationship between measured stations and specific rice planted regions during the rice straw burning episode.  相似文献   

10.
Surface coal mining creates more air pollution problems with respect to dust than underground mining . An investigation was conducted to evaluate the characteristics of the airborne dust created by surface coal mining in the Jharia Coalfield. Work zone air quality monitoring was conducted at six locations, and ambient air quality monitoring was conducted at five locations, for a period of 1 year. Total suspended particulate matter (TSP) concentration was found to be as high as 3,723 μg/m3, respirable particulate matter (PM10) 780 μg/m3, and benzene soluble matter was up to 32% in TSP in work zone air. In ambient air, the average maximum level of TSP was 837 μg/m3, PM10 170 μg/m3 and benzene soluble matter was up to 30%. Particle size analysis of TSP revealed that they were more respirable in nature and the median diameter was around 20 μm. Work zone air was found to have higher levels of TSP, PM10 and benzene soluble materials than ambient air. Variations in weight percentages for different size particles are discussed on the basis of mining activities. Anionic concentration in TSP was also determined. This paper concludes that more stringent air quality standards should be adopted for coal mining areas and due consideration should be given on particle size distribution of the air-borne dust while designing control equipment.  相似文献   

11.
在克拉玛依市中心城区布设4个采样点,在供暖期和非供暖期分别同步采集4个点位大气中不同粒径的颗粒物,采用HPLC进行分析并计算2个采样期内PM_(10)和PM_(2.5)中多环芳烃(PAHs)的浓度和种类。结果表明:中心城区供暖期PM_(10)中PAHs浓度为56.19 ng/m3,PM_(2.5)中PAHs浓度为48.85 ng/m3;中心城区非供暖期PM_(10)中PAHs浓度为18.86 ng/m~3,PM_(2.5)中PAHs浓度为14.53 ng/m~3。不同采样期PM_(10)和PM_(2.5)中PAHs浓度变化趋势相同,均为供暖期明显大于非供暖期。中心城区供暖期大气颗粒物吸附的PAHs以4环以下的组份为主,非供暖期则是5~6环的高环数组份偏多。分析结果表明克拉玛依市中心城区供暖期颗粒物中PAHs来源于燃煤排放叠加机动车排放,与中心城区集中供热锅炉关系密切;非供暖期则是以机动车排放污染为主。  相似文献   

12.
Evidence on the correlation between particle mass and (ultrafine) particle number concentrations is limited. Winter- and spring-time measurements of urban background air pollution were performed in Amsterdam (The Netherlands), Erfurt (Germany) and Helsinki (Finland), within the framework of the EU funded ULTRA study. Daily average concentrations of ambient particulate matter with a 50% cut off of 2.5 microm (PM2.5), total particle number concentrations and particle number concentrations in different size classes were collected at fixed monitoring sites. The aim of this paper is to assess differences in particle concentrations in several size classes across cities, the correlation between different particle fractions and to assess the differential impact of meteorological factors on their concentrations. The medians of ultrafine particle number concentrations were similar across the three cities (range 15.1 x 10(3)-18.3 x 10(3) counts cm(-3)). Within the ultrafine particle fraction, the sub fraction (10-30 nm) made a higher contribution to particle number concentrations in Erfurt than in Helsinki and Amsterdam. Larger differences across the cities were found for PM2.5(range 11-17 microg m(-3)). PM2.5 and ultrafine particle concentrations were weakly (Amsterdam, Helsinki) to moderately (Erfurt) correlated. The inconsistent correlation for PM2.5 and ultrafine particle concentrations between the three cities was partly explained by the larger impact of more local sources from the city on ultrafine particle concentrations than on PM2.5, suggesting that the upwind or downwind location of the measuring site in regard to potential particle sources has to be considered. Also, relationship with wind direction and meteorological data differed, suggesting that particle number and particle mass are two separate indicators of airborne particulate matter. Both decreased with increasing wind speed, but ultrafine particle number counts consistently decreased with increasing relative humidity, whereas PM2.5 increased with increasing barometric pressure. Within the ultrafine particle mode, nucleation mode (10-30 nm) and Aitken mode (30-100 nm) had distinctly different relationships with accumulation mode particles and weather conditions. Since the composition of these particle fractions also differs, it is of interest to test in future epidemiological studies whether they have different health effects.  相似文献   

13.
Different approaches are used to verify the adequacy of emission factors (EFs) and their use in emission inventories of persistent organic pollutants (POPs). The applicability of EFs was tested using atmospheric dispersion modelling to predict atmospheric concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and resulting toxic equivalents (SigmaTEQ) and particulate matter <10 microm (PM(10)) in two rural locations in northern England (UK). The modelling was based on general assumptions of fuel composition, consumption and heating needs to simulate emissions of POPs from the domestic burning of coal and wood where ambient measurements were made in the winter of 1998. The model was used to derive the local contribution to ambient air concentrations, which were estimated independently based on comparative air measurements. The results support the hypothesis that in both villages, the majority of PAHs and the lower chlorinated PCDFs were locally released. The situation for PCBs and polychlorinated naphthalenes (PCNs) was different. While the EFs show the release of both compound groups from the domestic burning of coal and wood, the ambient levels of these "legacy POPs" in the villages were still clearly dominated by other sources. Rural areas relying mainly on fossil fuels can exceed the proposed UK ambient air quality standard for benzo[a]pyrene during winter. The measured EFs were then used to estimate the importance of the domestic burning of coal and wood to national emission inventories for these compound classes. Extrapolations to the UK suggest that the domestic burning of pure wood and coal were minor emitters for chlorinated POPs but contributed strongly to PAH and PM(10) levels in 2000. Finally, the UK's national POPs emission inventories based on source inventories and EF, as used here, were compared to estimates derived using the increase in atmospheric concentration of selected POPs.  相似文献   

14.
The effect of fireworks on air quality was assessed from the ambient concentrations of various air pollutants (SO2, NO2, PM10 and TSP) during Diwali festival in Hisar city (India), in November 1999. The extensive use of fireworks was found to be related to short-term variation in air quality. During the festival the concentration of SO2 was observed to be increased approximately 10-fold at few sites, whereas the concentrations of NO2, PM10 and TSP increased 2-3 times, compared to the data collected on a typical winter day in December 1999. The maximum NO2 concentration was observed a day after the festival. The diurnal pattern of the above pollutants showed a slight increase in the night. The levels of these pollutants observed during Diwali were found to be moderately high, which can be associated with serious health impacts.  相似文献   

15.
We report on the CuPbZn content of PM10 and PM2.5 samples collected from three sites (urban T0, suburban T1 and rural T2) during the Mexico City MILAGRO campaign of March 2006. Daytime city centre concentrations of summation operator CuZnPb(PM10) were much higher (T0 > 450 ng m(-3)) than at the suburban site (T1 < 200 ng m(-3)). Rural site (T2) summation operator CuZnPb(PM10) concentrations exceeded 50 ng m(-3) when influenced by the megacity plume but dropped to 10 ng m(-3) during clean northerly winds. Nocturnal metal concentrations more than doubled at T0, as pollutants became trapped in the nightly inversion layer, but decreased at the rural site. Transient spikes in concentrations of different metals, e.g. a "copper event" at T0 (CuPM10 281 ng m(-3)) and "zinc event" at T1 (ZnPM10 1481 ng m(-3)) on the night of March 7-8, demonstrate how industrial pollution sources produce localised chemical inhomogeneities in the city atmosphere. Most metal aerosols are <2.5 microm and SEM study demonstrates the dominance of Fe, Ti, Ba, Cu, Pb and Zn (and lesser Sn, Mo, Sb, W, Ni, V, As, Bi) in metalliferous particles that have shapes including spherical condensates, efflorescent CuZnClS particles, cindery Zn, and Cu wire. Metal aerosol concentrations do not change in concert with PM10 mass, which is more influenced by wind resuspension than industrial emissions. Metalliferous particles can induce cell damage, and PM composition is probably more important than PM mass, with respect to negative health effects, so that better monitoring and control of industrial emissions would likely produce significant improvements in air quality.  相似文献   

16.
Food cooking using liquefied petroleum gas (LPG) has received considerable attention in recent years since it is an important source of particulate air pollution in indoor environments for non-smokers. Exposure to organic compounds such as polycyclic aromatic hydrocarbons (PAHs) contained in particles is of particular health concern since some of these compounds are suspected carcinogens. It is therefore necessary to chemically characterize the airborne particles emitted from gas cooking to assess their possible health impacts. In this work, the levels of fine particulate matter (PM(2.5)) and 16 priority PAHs were determined in three different ethnic commercial kitchens, specifically Chinese, Malay and Indian food stalls, where distinctive cooking methods were employed. The mass concentrations of PM(2.5) and PAHs, and the fraction of PAHs in PM(2.5) were the highest at the Malay stall (245.3 microg m(-3), 609.0 ng m(-3), and 0.25%, respectively), followed by the Chinese stall (201.6 microg m(-3), 141.0 ng m(-3), and 0.07%), and the Indian stall (186.9 microg m(-3), 37.9 ng m(-3), and 0.02%). This difference in the levels of particulate pollution among the three stalls may be attributed to the different cooking methods employed at the food stalls, the amount of food cooked, and the cooking time, although the most sensitive parameter appears to be the predominant cooking method used. Frying processes, especially deep-frying, produce more air pollutants, possibly due to the high oil temperatures used in such operations. Furthermore, it is found that frying, be it deep-frying at the Malay stall or stir-frying at the Chinese stall, gave rise to an abundance of higher molecular weight PAHs such as benzo[b]fluoranthene, indeno[1,2,3-cd]pyrene and benzo[g,h,i]perylene whereas low-temperature cooking, such as simmering at the Indian stall, has a higher concentration of lower molecular weight PAHs. In addition, the correlation matrices and diagnostic ratios of PAHs were calculated to determine the markers of gas cooking. To evaluate the potential health threat due to inhalation exposure from the indoor particulate pollution, excess lifetime cancer risk (ELCR) was also calculated for an exposed individual. The findings suggest that cooking fumes in the three commercial kitchens pose adverse health effects.  相似文献   

17.
Particle-bound PAHs were measured at three sites in southeastern Spain (an urban background location, a suburban-industrial site in the vicinity of two cement plants and a rural area) in order to investigate the influence of the type of location on PAH concentrations. A clear influence of cement production on particulate PAH levels could not be established since for the urban background and suburban-industrial sites the average concentrations of total PAHs in the PM2.5 fraction were very similar (1.085 and 1.151 ng m(-3), respectively), with benzo[b+k]fluoranthene and chrysene as the predominant compounds. Diagnostic ratios, used to identify PAH emission sources, pointed to traffic as the main source of particulate PAH at both locations. As expected, PAH levels at the rural site were significantly lower (0.408 ng m(-3) in the PM10 fraction) due to increasing distance from the emission sources. PAH seasonal variations at the urban background and suburban-industrial sites were the same as reported in many previous studies. Average winter to summer ratios for total PAHs were 4.4 and 4.9 for the urban background and industrial sites, in that order. This seasonal cycle could be partially explained by the higher temperature and solar radiation during summer enhancing PAH evaporation from the particulate phase and PAH photochemical degradation, respectively. The study of PAH distribution between the fine and coarse fraction at the urban site revealed that on average around 80% of total PAHs were associated with fine particles.  相似文献   

18.
Endotoxin is a toxic, pro-inflammatory compound that has been detected in indoor air and dust in homes and occupational settings, and also in outdoor air. Data on the outdoor sampling of endotoxin are limited. Currently, little is known about the seasonal variation and influence of temperature on outdoor endotoxin levels. In the present study, we report endotoxin levels in fine fraction particulate matter with a 50% aerodynamic cutoff diameter of 2.5 microm (PM2.5) and describe the seasonal variation of endotoxin in Munich, Germany. In 1999-2000, PM2.5 was collected at forty outdoor monitoring sites across Munich. Approximately four samples were collected at each site for a total of 158 samples. Endotoxin concentrations in the PM2.5 samples were determined using the kinetic chromogenic Limulus Amebocyte Lysate (LAL) assay. The geometric mean endotoxin concentration was 1.07 EU mg PM2.5(-1) (95% C.I.: 0.915-1.251) or 0.015 EU m(-3) of sampled air (95% C.I.: 0.013-0.018). Munich endotoxin levels were significantly related to ambient temperature (p < 0.0001) and percent relative humidity (p < 0.0001). Sampling periods with higher average temperatures yielded higher levels of endotoxin in PM2.5 (r = 0.641), whereas decreases in percent relative humidity were associated with increased endotoxin levels in PM2.5 (r = -0.388). Endotoxin levels were significantly higher during the warmer seasons of spring [means ratio (MR): 2.5-2.7] and summer (MR: 2.1-3.0) than during winter. Although temperature and relative humidity do not explain all of the variability in endotoxin levels, their effects were significant in our data set. Temperature effects and seasonal variation of endotoxin should be considered in future studies of outdoor endotoxin.  相似文献   

19.
Emission from field burning of agricultural crop residue is a common environmental hazard observed in northern India. It has a significant potential health risk for the rural population due to respirable suspended particulate matter (RSPM). A study on eight stage size segregated mass distribution of RSPM was done for 2 wheat and 3 rice crop seasons. The study was undertaken at rural and agricultural sites of Patiala (India) where the RSPM levels remained close to the National Ambient Air quality standards (NAAQS). Fine particulate matter (PM(2.5)) contributed almost 55% to 64% of the RSPM, showing that, in general, the smaller particles dominated during the whole study period with more contribution during the rice crop as compared to that of wheat crop residue burning. Fine particulate matter content in the total RSPM increased with decrease in temperature. Concentration levels of PM(10) and PM(2.5) were higher during the winter months as compared to that in the summer months. Background concentration levels of PM(10), PM(2.5) and PM(10-2.5) were found to be around 97 ± 21, 57 ± 15 and 40 ± 6 μg m(-3), respectively. The levels increased up to 66, 78 and 71% during rice season and 51, 43 and 61% during wheat crop residue burning, respectively. Extensive statistical analysis of the data was done by using pair t-test. Overall results show that the concentration levels of different size particulate matter are greatly affected by agricultural crop residue burning but the total distribution of the particulate matter remains almost constant.  相似文献   

20.
In this work we present the results of extensive characterization and optimization of the Ambient Ion Monitor-Ion Chromatograph (AIM-IC) system, an instrument developed by URG Corp. and Dionex Inc. for simultaneous hourly measurements of the water-soluble chemical composition of atmospheric fine particulate matter (PM(2.5)) and associated precursor gases. The sampling assembly of the AIM-IC consists of an inertial particle size-selection assembly, a parallel-plate wet denuder (PPWD) for the collection of soluble gases, and a particle supersaturation chamber (PSSC) for collection of particles, in series. The analytical assembly of the AIM-IC consists of anion and cation IC units. The system detection limits were determined to be 41 ppt, 5 ppt, and 65 ppt for gas phase NH(3(g)), SO(2(g)), and HNO(3(g)) and 29 ng m(-3), 3 ng m(-3), and 45 ng m(-3) for particle phase NH(4)(+), SO(4)(2-), and NO(3)(-) respectively. From external trace gas calibrations with permeation sources, we determined that the AIM-IC is biased low for NH(3(g)) (11%), SO(2(g)) (19%), and HNO(3(g)) (12%). The collection efficiency of SO(2(g)) was found to strongly depend on the composition of the denuder solution and was found to be the most quantitative with 5 mM H(2)O(2) solution for mixing ratios as high as 107 ppb. Using a cellulose membrane in the PPWD, the system responded to changes in SO(2(g)) and HNO(3(g)) within an hour, however for NH(3(g)), the timescale can be closer to 20 h. With a nylon membrane, the instrument response time for NH(3(g)) was significantly improved, becoming comparable to the responses for SO(2(g)) and HNO(3(g)). Performance of the AIM-IC for collection and analysis of PM(2.5) was evaluated by generating known number concentrations of ammonium sulfate and ammonium nitrate particles (with an aerodynamic diameter of 300 nm) under laboratory conditions and by comparing AIM-IC measurements to measurements from a collocated Aerosol Mass Spectrometer (AMS) during a field-sampling campaign. On average, the AIM-IC and AMS measurements agreed well and captured rapid ambient concentration changes at the same time. In this work we also present a novel inlet configuration and plumbing for the AIM-IC which minimizes sampling inlet losses, reduces peak smearing due to sample carryover, and allows for tower-height sampling from the base of a research tower.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号