首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ABSTRACT: Efficient operation of a city water supply system is an important goal of all municipalities. Efficient operation should result in minimum operation cost through reduction in total energy use and/ or reduction in on-peak energy consumption. An optimization model was designed for operating the water supply systems of cities using groundwater. The Newton-Raphson pipe network was used for network analysis and a dynamic programming optimization algorithm was used for determining a schedule for pump operation in the pipe network system. The model is most suitable for use in small cities with up to 45,000 in population, but with large-scale disintegration techniques may also be used for larger cities. The savings in operation costs are a function of energy cost and energy use pattern and water use pattern in the area.  相似文献   

2.
Rainwater tanks for larger roof areas need optimisation of tank size, which is often not carried out before installation of these tanks. This paper presents a case study of rainwater tank evaluation and design for large roof areas, located in Melbourne, Australia, based on observed daily rainfall data representing three different climatic regimes (i.e. dry average, and wet years). With the aim of developing a comprehensive Decision Support Tool for the performance analysis and design of rainwater tanks, a simple spreadsheet based daily water balance model is developed using daily rainfall data, contributing roof area, rainfall loss factor, available storage volume, tank overflow and irrigation water demand. In this case study, two (185 m3 and 110 m3) underground rainwater tanks are considered. Using the developed model, effectiveness of each tank under different climatic scenarios are assessed. The analysis shows that both the tanks are quite effective in wet and average years, however less effective in dry years. A payback period analysis of the tanks is preformed which reveals that the total construction cost of the tanks can be recovered within 15-21 years time depending on tank size, climatic conditions and future water price increase rates. For the tanks, a relationship between water price increase rates and payback periods is developed. The study highlights the need for detailed optimisation and financial analysis for large rainwater tanks to maximise the benefits.  相似文献   

3.
ABSTRACT: In the near future, groundwater storage of imported water may become increasingly important as sites for surface storage are less available. This article explores the potential economic costs and benefits of groundwater storage. The costs include capital outlays, maintenance costs, land costs, legal costs, energy costs, and opportunity costs. The benefits include land cost savings, prevention of subsidence, aquifer protection, and higher economic use of surface lands that might be covered by a reservoir.  相似文献   

4.
Solar energy is one of the most important renewable energy sources, but it is not available every time and every season. Thus, storing of solar energy is important. One of the popular methods of heat storage is use of phase change materials (PCMs) which have large thermal energy storage capacity. In this study, the heat storage tank in a domestic solar water heating system was chosen as control volume. The experiments were performed in the province of Elaz?g, Turkey, in November when solar radiation was weak due to cloudy sky. The heat storage tank of the system was modified to fill PCM between insulation and hot water part. A few PCMs which are Potassium Fluoride, Lithium Metaborate Dihydrate, Strontium Hydroxide Octahydrate, Barium Hydroxide Octahydrate, Aluminum Ammonium Sulfate, and Sodium Hydrogen Phosphate were analyzed to proper operating conditions using a Differential Scanning Calorimeter (DSC) and the best PCM was obtained with the Aluminum Ammonium Sulfate and Sodium Hydrogen Phosphate mixture. Thus, eutectic PCM was obtained and used in a heat storage tank of the solar water heating system. Energy and exergy analysis of heat storage tank was performed with and without the PCM. Energy and exergy analysis has shown that the heat storage tank with the PCM is more efficient than without the PCM and the maximum exergy efficiency was obtained as 22% with the heat storage tank with the PCM.  相似文献   

5.
A novel deterministic multi-period mixed-integer linear programming (MILP) model for the power generation planning of electric systems is described and evaluated in this paper. The model is developed with the objective of determining the optimal mix of energy supply sources and pollutant mitigation options that meet a specified electricity demand and CO2 emission targets at minimum cost. Several time-dependent parameters are included in the model formulation; they include forecasted energy demand, fuel price variability, construction lead time, conservation initiatives, and increase in fixed operational and maintenance costs over time. The developed model is applied to two case studies. The objective of the case studies is to examine the economical, structural, and environmental effects that would result if the electricity sector was required to reduce its CO2 emissions to a specified limit.  相似文献   

6.
选取天津市某小区,采用美国环保署开发的SWMM模型,模拟得出小区在开发建设前后的区域出口流量过程线和总径流量,分析评价了蓄水池和下凹绿地对小区雨水径流情况的影响。计算满足建设用地外排雨水设计流量不大于开发建设前水平这一条件时,蓄水池的设计体积和下凹绿地的面积以及下凹深度。模拟结果表明,蓄水池和下凹绿地可同时消减洪峰,推...  相似文献   

7.
ABSTRACT: The effects of variable discharges during the summer on the dissolved oxygen (DO) content and water temperature upstream and downstream of the Conowingo Hydroelectric Power Station were investigated. The DO dynamics are controlled primarily by meteorological factors that are independent of the mode of hydrostation operation. DO stratification occurred during the summer in Conowingo Pond, but thermal stratification was not observed. The magnitude and duration of off-peak discharges including a run-of-the-river operation did not affect DO stratification in Conowingo Pond; little vertical mixing occurred. However, strong winds and/or high river flows temporarily destroyed DO stratification. The run-of-the-river operation or off-peak continuous discharge schemes did not provide better DO conditions downstream of the hydrostation than the peaking operation with intermittent off-peak releases. A statistical model predicted that a DO of 5 ppm occurs 0.6 miles downstream of the powerhouse when the natural river flow is consistently greater than 15,000 cfs and water temperature is less than 80°F. A mean daily DO of at least 4 ppm was predicted to occur over 80 percent of the time during the 92-day summer period. Farther downstream (1.3 miles from the powerhouse) a mean daily DO of at least 4 ppm was predicted to occur 90 percent of the time in summer.  相似文献   

8.
Transfers of treated water among inter-connected utilities is becoming more common as the cost of developing new supplies grows, and transfer agreements require well developed rules describing when and how much water will be transferred. The nature of the decision rules governing an agreement must also be coordinated with respect to the treatment and conveyance capacity required to execute the transfers. This study explores different combinations of infrastructure and agreement type that define three different transfer programs, describing the frequency and volume of transfers associated with each, as well as their costs. The agreements are described in terms of the type of decision rule employed: Take-or-Pay, where the timing and quantity of transfers is fixed; Days of Supply Remaining (DSR), which uses a static hydrologic indicator to trigger transfers; and Risk-of-Failure, a probability-based decision rule that involves consideration of both supply and demand. This analysis is conducted within the context of the Research Triangle area of North Carolina (USA), a rapidly growing area that is beginning to approach the practical limits of water resource development. The Risk-of-Failure agreement is shown to reduce the average volume of transfers by over 80% compared to a Take-or-Pay agreement and by roughly half relative to the DSR agreement, leading to significant cost reductions. A utility's willingness to accept something less than guaranteed access to a specified quantity of water (i.e. an interruption) also has a significant impact on cost. Interruptions do not necessarily lead to lower reliability, but rather to the purchasing utility acquiring more water during off-peak periods when the seller has excess treatment capacity available. The lowest cost guaranteed agreement is 40–50% more expensive than the lowest cost interruptible contract.  相似文献   

9.
Due to environmental constraints and reactive water management practices, water shortages exist across the Everglades ecosystem. A growing human population and continued wetlands damage and loss decrease the system's ability to provide water for sustained natural areas and for human uses. 'The Restudy' is an $8 billion plan to restore the Everglades while also continuing to provide water storage for urban and agricultural areas. The Restudy proposes a mix of water storage systems to provide for the predicted future growth in water demand. This mix is purported to be the most cost-efficient at providing water supplies, within the constraints of unchanged agricultural and urban land use. However, a sensitivity analysis of the Restudy's cost equation reveals that the total cost of water storage systems is influenced by real estate, land acquisition and water treatment costs. The interaction of land use and agricultural policies can affect these cost factors, and can change the relative cost-efficiency between storage systems. Real estate and land acquisition costs are affected by several 1996 Farm Bill provisions, which influence the cost of aboveground water storage systems versus Aquifer Storage and Recovery systems. The Governor's Commission for a Sustainable South Florida recommendations also influence the water storage options available to the Restudy. Due to the Restudy's initial assumptions and constraints, it may not advocate the most economically and ecologically sound remediation.  相似文献   

10.
ABSTRACT: A study was undertaken to see if benefits from water supply could be increased by utilizing price-usage information in reservoir design studies. Three pricing policies were examined. The first policy assumed no price-use relationship, and quantity demanded was based on existing community usage with a low water rate. The price of water was set to recover system costs. A price-use relationship was assumed in the second policy and the water rate was constant. The price of water was determined from the associated system which provided maximum expected net benefits. The third policy assumed the price-use relationship and the price charged for water during each billing period was a non-linear function of storage which increased as the amount of water in storage at the beginning of the period decreased. It was found that the use of the conservation pricing policies substantially reduced storage requirements while providing demonstrable net benefits to the community and a large average supply. The conservation pricing policies substantially lowered the average price paid for water. The effect of uncertainty in consumer response to changes in price was studied by using a probabilistic price-use relationship. This uncertainty did not significantly reduce the effectiveness of the conservation policy. It was concluded that demand management by the use of a proper pricing policy could significantly increase net water supply benefits to a community.  相似文献   

11.
ABSTRACT: To help meet national energy demands, interest has been focused on the coal, oil shale, and uranium deposits of the Upper Colorado River Basin. Several energy output projections for the basin have been presented based upon water availability. Inherent in all these analyses are estimates as to the rate of water use in each energy development. New energy technologies are characterized by parameters extrapolated from small scale energy facilities. The data provide projected costs, conversion efficiencies, and material inputs and outputs. Alternative techniques for process cooling and solids handling provide variable rates of water use which affect other conversion parameters. Results from a mathematical model are used in analyzing the sensitivity of an optimal energy development strategy for the Upper Colorado River Basin. The impacts of alternative water use rates are investigated in terms of net energy output, total cost, and displacements in the development strategy. Similarly, controls and regulations on energy resource development are evaluated.  相似文献   

12.
Population growth in the Southeast has driven withdrawals for municipal water beyond the limits of local supplies. With few options left for development of virgin sources, a number of urban areas are looking toward demand management and additional supplies by reallocating storage in reservoirs that were built primarily or in part for hydropower. Hydropower has become a lesser part of the mix of energy sources, and the question arises as to value of water for that purpose relative to its value for municipal use. Three cases are used to examine the issue. Effects of withdrawal for municipal water supply on output of electric energy are estimated. Benefits of foregone energy are evaluated using the least cost alternative for replacement, and benefits for municipal water are estimated using costs for development of new sources. Benefits for use as municipal water are found to be considerably higher than benefits for hydroelectric energy at existing prices, even higher than the least cost alternative for replacement. Given the spatial distribution of the cases, that finding would appear to hold in general across the region.  相似文献   

13.
Two free water surface (FWS) and two subsurface flow (SSF) pilot-size wetlands were constructed for the evaluation of their performance in treating highway runoff (HRO) in the heart of the Mediterranean region, the island of Crete, at the southernmost point of Greece. Detailed recordings of the resources involved during the construction allowed a thorough calculation of the cost of the systems and the requirements in materials, man-hours, and equipment. The two identical FWS systems had a surface area of 33 m2 each, while the two identical SSF covered 32 m2 each. One FWS and one SSF, named FWS12 and SSF12, respectively, were designed with a hydraulic retention time (HRT) of 12 h, with each one capable of treating a maximum HRO of 12.6 m3/day. The other couple, named FWS24 and SSF24, respectively, was designed with an HRT of 24 h, with each receiving a maximum HRO of 6.3 m3/days. An influent storage tank was required to hold the runoff during the common storm events and control the flow rate (and the hydraulic retention time) into the wetlands. This construction represented 25% of the total construction cost, while 5% was spent on the influent automated (and sun-powered) control and distribution system, from the storage tank to the wetlands. The respective total cost allocated to the two SSF systems (€14,676) was approximately 10% higher than that of the FWS (€13,596), mainly due to the three different-sized gravel layers used in the SSF substrate compared to the topsoil used in the FWS, which tripled the cost and placement time. The Total Annual Economic Cost (TAEC) was €1799/year and €1847/year for the FWS and SSF pair, respectively. TAEC was also used to compare the economic efficiency of the systems per cubic meter of HRO treated and kilograms of COD and TSS removed from the wetlands during their first operational year. Based on these estimations, FWS12 recorded the lowest TAECCOD and TAECTSS values (€89.09/kg and €43.69/kg, respectively) compared to the other three systems, presenting a more economically favorable option.  相似文献   

14.
ABSTRACT: A flood control reservoir protects valuable developments on the downstream flood plain by storing flood waters and releasing them at a rate that will reduce the downstream damage. The water surface level of the flood pool behind the dam can fluctuate considerably during the occurrence of a large magnitude flood causing the inundation of trees, low vegetation, and water based recreation facilities located in those areas of the flood pool area that are normally well above the water level. The amount of damage that will occur in the upper levels of the flood storage area will depend on the depth and duration of the inundation that occurs. This, in turn, is directly related to the operating policy for the reservoir. A dynamic programming optimization model of flood control reservoir operation is presented. This model determines the reservoir operating schedule that minimizes downstream flood damages. Various constraints are added to the model to account for the environmental impacts of long periods of flood storage.  相似文献   

15.
The current sanitation technology in developed countries is based on diluting human excreta with large volumes of centrally provided potable water. This approach is a poor use of water resources and is also inefficient, expensive, and energy intensive. The goal of this study was to compare the standard sanitation technology (Scenario 1) with alternative technologies that require less or no potable water use in toilets. The alternative technologies considered were high efficiency toilets flushed with potable water (Scenario 2), standard toilets flushed with rainwater (Scenario 3), high efficiency toilets flushed with rainwater (Scenario 4), and composting toilets (Scenario 5). Cost, energy, and carbon implications of these five design scenarios were studied using two existing University of Toledo buildings. The results showed that alternative systems modeled in Scenarios 2, 4, and 5 were viable options both from an investment and an environmental performance perspective. High efficiency fixtures that use potable water (Scenario 2) is often the most preferred method in high efficiency buildings due to reduced water use and associated reductions in annual water and wastewater costs. However, the cost, energy, and CO(2)EE analyses all showed that Scenarios 4 and 5 were preferable over Scenario 2. Cost payback periods of scenarios 2, 4 and 5 were less than 10 years; in the future, increase in water and wastewater services would further decrease the payback periods. The centralized water and wastewater services have high carbon footprints; therefore if carbon footprint reduction is a primary goal of a building complex, alternative technologies that require less potable water and generate less wastewater can largely reduce the carbon footprint. High efficiency fixtures flushed with rainwater (Scenario 4) and composting toilets (Scenario 5) required considerably less energy than direct energy demands of buildings. However, the annual carbon footprint of these technologies was comparable to the annual carbon footprint from space heating. Similarly, the carbon savings that could be achieved from Scenario 4 or 5 were comparable to a recycling program that can be implemented in buildings.  相似文献   

16.
ABSTRACT: A deterministic dynamic programming optimization model with a refining sectioning search procedure is developed and implemented to find least cost withdrawal and release patterns for water supple from a multiple reservoir system serving a metropolitan area. Applications are made to teh four reservoir system operated by the city of Dallas, Texas. A realistic cost structure, including nonlinear power consumption, block rate unit power costs, and flow dependent power consumption for intracity water distribution, is utilized. Applications are made to find least cost operating patterns and, as well, by inclusion of a water loss penalty function, supply patterns which will reduce evaporation water losses for the Dallas system.  相似文献   

17.
ABSTRACT: Varying treatment levels to meet seasonal variation in assimilative capacity of streams can reduce total costs of treatment. A mathematical model of a Pennsylvania stream based on a theoretically sound approximation of the physical relationships underlying the distribution of DO in a river system was used to determine discharge constraints for an economic optimization model which produced estimates of sewage treatment cost savings. Increasing the number of flow periods during the year enhances cost reducing opportunities even when land application processes are considered. Also, the least cost treatment process for year around operation may not be the least costly under multiple flow period management.  相似文献   

18.
Rowe, Mark P., 2011. Rain Water Harvesting in Bermuda. Journal of the American Water Resources Association (JAWRA) 47(6):1219–1227. DOI: 10.1111/j.1752‐1688.2011.00563.x Abstract: Roof‐top rain water harvesting is mandated by law for all buildings in Bermuda and is the primary source of water for domestic supply. The average rate at which rain water is harvested at the typical house with four occupants is, however, insufficient to meet average demand. While just over one‐third of households have access to supplementary water either from mains pipelines or private wells, the majority rely on deliveries from water “truckers” (tankers) to augment their rain water supply. Assuming a reasonably constant daily demand, there is a linear relationship between the “maximum optimum capacity” of a water storage tank and the size of the rain water catchment area, which depends on the characteristics of the rainfall at a given geographic location. A simple spreadsheet model was developed to simulate tank storage levels for various combinations of catchment area, tank capacity, and demand, with an input of actual daily rainfall data for a study period of nearly three years. It was found that for typical cycles of rainfall surpluses and deficits in Bermuda, the tank capacity which there is no benefit in exceeding — the “optimum maximum capacity”— is 0.37 m3 of storage capacity per 1 m2 of catchment area. Furthermore, it was concluded that many domestic water storage tanks in Bermuda are larger than necessary, especially so where there is a significant imbalance between rain water supply and demand.  相似文献   

19.
ABSTRACT: A mathematical model of agricultural water use and a hydrological and economic simulation model were linked to quantify the economic and hydrological impact of deficit irrigation, increased water application efficiency, and farm storage dams when maintaining an IFR (instream flow requirement) under stochastic water supply conditions. The main finding was that a water conservation policy aimed at reducing the amount of water withdrawn from the river could bring more pressure to bear on stream flow. Water can only be saved if consumptive use is reduced. Increased water application efficiency is detrimental to other users as a result of reduced return flow. The economic cost of maintaining a specific IFR increases with the use of all three strategies as the probability of maintaining the IFR increases. Because of the control that can be exercised over the supply of water, a farm storage dam is the best strategy for minimizing the costs for irrigators. The interaction between water legislation, water policy administration, technology, hydrology, and human value systems necessitates an integrated approach to facilitate water management at catchment level and to formulate policies that will be in the interest of society.  相似文献   

20.
Experiments are described to investigate the thermal performance of a discharging heat exchanger for a small storage tank filled with oil. Experimental results are presented in terms of the discharging energy rates (power) and the discharging exergy rates for low (~4 ml/s) and high discharging flow rates (~8 ml/s). Water heating energy rates, which are respectively maximized at approximately 600 W and 1200 W at low and high flow-rate discharging, are found to be higher than the discharging energy rates, which are respectively maximized at 450 W and 900 W. These results indicate that the energy rates do not accurately evaluate the thermal performance of the discharging heat exchanger since the energy heating rate of the water is greater than that for the oil that heats it, which is thermodynamically inconsistent. The energy rates should thus be used with caution when the thermal performance of the heat exchanger is evaluated. Water heating exergy rates, which are respectively maximized at approximately 45 W and 130 W at low and high flow-rate discharging, are generally smaller than the discharging exergy rates, which are respectively maximized at 65 W and 170 W. Exergy rate results are thus more consistent in the physical process of water heating, and an exergy factor is suggested as a proper measure for evaluating the performance of the discharging heat exchanger. The maximum value of the exergy factor is found to increase from 0.15 at low flow rates to a maximum value of approximately 0.19 at high flow rates. This implies that to extract more energy from a storage tank to a discharging heat exchanger, the flow rate has to be high, which is consistent with the physical process of heating water faster to higher temperatures. The exergy factor can thus be used as a design parameter for discharging heat exchangers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号