Considering the quality of design and construction of landfills in developing countries, little information can be derived from randomly taken leachate samples. Leachate generation and composition under monsoon conditions have been studied using lysimeters to simulate sanitary landfills and open cell settings. In this study, lysimeters were filled with domestic waste, highly organic market waste and pre-treated waste. Results over two subsequent dry and rainy seasons indicate that the open cell lysimeter simulation showed the highest leachate generation throughout the rainy season, with leachate flow in all lysimeters coming to a halt during the dry periods. More than 60% of the precipitation was found in the form of leachate. The specific COD and TKN load discharged from the open cell was 20% and 180% more than that of the sanitary landfill lysimeters. Types of waste material and kind of pre-treatment prior to landfilling strongly influenced the pollutant load. Compared to the sanitary landfill lysimeter filled with domestic waste, the specific COD and TKN load discharged from the pre-treated waste lysimeter accounted for only 4% and 16%, respectively. Considering the local settings of tropical landfills, these results suggest that landfill design and operation has to be adjusted. Leachate can be collected and stored during the rainy season, and recirculation of leachate is recommended to maintain a steady and even accelerated degradation during the prolonged dry season. The open cell approach in combination with leachate recirculation is suggested as an option for interim landfill operations.  相似文献   

2.
Research on leachate recirculation from different types of landfills   总被引:5,自引:0,他引:5  
Landfills can produce a great amount of leachate containing highly concentrated organic matter. This is especially true for the initial leachate from landfilled municipal solid wastes (MSW) that generally has concentrations of COD(Cr) and BOD(5) up to 80,000 and 50,000mg/L, respectively. The leachate could be disposed by means of recirculating technique, which decomposes the organics through the action of proliferating microorganisms and thereby purifies the leachate, and simultaneously accelerates organic decomposition through water saturation control. Data from experimental results indicated that leachate recirculating could reduce the organic concentration considerably, with a maximum reduction rate of COD(Cr) over 95%; and, using a semi-aerobic process, NH(3)-N concentration of treated leachate could be under 10mg/L. In addition, the organic concentration in MSW decreased greatly.  相似文献   

3.
This study aims to characterize the leachate and to investigate the tropical climatic influence on leachate characteristics of lysimeter studies under different seasonal variations at KUET campus, Bangladesh. Three different situations of landfill were considered here as well as both the open dump lysimeter-A having a base liner and sanitary landfill lysimeter-B and C at two different types of cap liner were simulated. The leachate characteristics, leachate generation and climatic influence parameter had been continually monitored since June 2008 to May 2010, these periods cover both the dry and rainy season. The leachate generation had followed the rainfall pattern and the open dump lysimeter-A without top cover was recorded to have highest leachate generation. Moreover, the open dump lysimeter-A had lower total kjeldahl nitrogen (TKN), ammonia nitrogen (NH(4)-N) and TKN load, while both the COD concentration and load was higher compared with sanitary landfill lysimeter-B and C. In addition, sanitary landfill lysimeter-B, not only had lowest leachate generation, but also produces reasonable low COD concentration and load compared with open dump lysimeter-A. Result reveals that lysimeter operational mode had direct effect on leachate quality. Finally, it can be concluded that the knowledge of leachate quality will be useful in planning and providing remedial measures of proper liner system in sanitary landfill design and leachate treatment.  相似文献   

4.
Two fresh refuse bioreactors (F1 and F2) were operated under semi-aerobic and anaerobic conditions, respectively. The leachate from the bioreactors F1 and F2 was introduced into the aged refuse bioreactors (A1 and A2), and the effluent from A1 and A2 was subsequently recirculated into F1 and F2, respectively. The effect of the semi-aerobic recirculation process on refuse degradation was investigated, comparing it with that of the anaerobic recirculation process. Results indicate that the semi-aerobic recirculation process can increase the accumulated net production of leachate and promote evaporation. The accumulated net production of refuse in F1 is 320 mL/kg and that of F2 is 248 mL/kg, with leachate reduction amounting to 315 and 244 mL/kg refuse, respectively. The leachate quantity reduction of semi-aerobic and anaerobic leachate recirculation process accounted for 98.4% and 98.3% of the accumulated net production of leachate, respectively. The semi-aerobic leachate recirculation process can improve the biodegradation of organic matter from fresh refuse and the reduction rate of the pollutant concentration in leachate. This should shorten considerably the time required to meet the discharge standard and the time of stabilization of the refuse as observed in the anaerobic recirculation process. It was predicted that the COD concentration of leachate from the anaerobic recirculation process would reach 1000 mg/L in the anaerobic recirculation process after 2.2 years, as for semi-aerobic leachate recirculation process it is about 100 days. Compared with anaerobic recirculation process, the semi-aerobic recirculation process is more effective on NH3-N transformation and TN removal. The NH3-N and TN concentration of F1 is far below those of F2 at the end of our experiment. Refuse settlement in the semi-aerobic recirculation process was faster than that in the anaerobic recirculation process. At the end of the experiment, refuse settlement ratios in the semi-aerobic and anaerobic bioreactors were 33.5% and 18%, respectively.  相似文献   

5.
Performance evaluation of pilot scale sub-surface constructed wetlands was carried out in treating leachate from Pulau Burung Sanitary Landfill (PBSL). The constructed wetland was planted with Cyperus haspan with sand and gravel used as substrate media. The experiment was operated for three weeks retention time and during the experimentation, the influent and effluent samples were tested for its pH, turbidity, color, total suspended solid (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD(5)), ammonia nitrogen (NH(3)-N), Total phosphorus (TP), total nitrogen (TN) and also for heavy metals such as iron (Fe), magnesium (Mg), manganese (Mn) and zinc (Zn) concentrations. The results showed that the constructed wetlands with C. haspan were capable of removing 7.2-12.4% of pH, 39.3-86.6% of turbidity, 63.5-86.6% of color, 59.7-98.8% of TSS, 39.2-91.8% of COD, 60.8-78.7% of BOD(5), 29.8-53.8% of NH(3)-N, 59.8-99.7% of TP, 33.8-67.0% of TN, 34.9-59.0% of Fe, 29.0-75.0% of Mg, 51.2-70.5% of Mn, and 75.9-89.4% of Zn. The significance of removal was manifested in the quality of the effluent obtained at the end of the study. High removal efficiencies in the study proved that leachate could be treated effectively using subsurface constructed wetlands with C. haspan plant.  相似文献   

6.
The State of México, situated in central México, has a population of about 14 million, distributed in approximately 125 counties. Solid waste management represents a serious and ongoing pressure to local authorities. The final disposal site ("El Socavón") does not comply with minimum environmental requirements as no liners or leachate management infrastructure are available. Consequently, leachate composition or the effects of rain water input on municipal solid waste degradation are largely unknown. The aim of this work was to monitor the anaerobic degradation of municipal solid waste (MSW), simulating the water addition due to rainfall, under two different moisture content regimes (70% and 80% humidity). The study was carried out using bioreactors in both laboratory and pilot scales. The variation of organic matter and pH was followed in the solid matrix of the MSW. The leachate produced was used to estimate the field capacity of the MSW and to determine the pH, COD, BOD and heavy metals. Some leachate parameters were found to be within permitted limits, but further research is needed in order to analyze the leachate from lower layers of the disposal site ("El Socavón").  相似文献   

7.
The patterns of settlement of fresh as well as partially stabilised municipal solid waste (MSW), undergoing degradation in five different landfill lysimeters, were studied elaborately. The first two lysimeters, R1 and R2, contained fresh MSW while the other three lysimeters, R3, R4 and R5, contained partially stabilised MSW. R1 and R3 simulated conventional controlled dumps with fortnightly disposal of drained leachate. R2 and R4 simulated bioreactor landfills with leachate recirculation. Fortnightly water flushing was done in R5. Settlement of MSW, monitored over a period of 58 weeks, was correlated with the organic carbon content of leachate and residual volatile matter in the MSW to establish the relationship between settlement and organic destruction. Compressibility parameters such as modulus of elasticity and compression indices were determined and empirical equations were applied for the settlement data. Overall settlements up to 49% were observed in the case of landfill lysimeters, filled with fresh MSW. Landfill lysimeters with liquid addition, in the form of leachate or water, experienced lower primary settlements and higher secondary settlements than conventional fills, where no liquid addition was practised. Modified secondary compression indices for MSW in lysimeters with leachate recirculation and flushing were 30%-44% higher than that for lysimeters where no liquid addition was done. Secondary settlements in bioreactor landfills were found to vary exponentially with time.  相似文献   

8.
A three-compartment system, comprising a landfill column with fresh municipal solid waste, a column with a well-decomposed refuse layer as methane producer, and a sequential batch reactor as ex situ nitrifying reactor, was employed to remove nitrogen from municipal solid waste leachate. Since food waste comprised a major portion of refuse collected in Shanghai, an intense hydrolysis reaction occurred and caused the rapid accumulation of ammonia nitrogen (NH(3)-N) and total organic carbon in the leachate. This paper discusses the role of the three mentioned units and the design and operation of the proposed system. With most NH(3)-N being converted to nitrite nitrogen (NO(2)(-)-N) or nitrate nitrogen (NO(3)(-)-N) by the nitrifying reactor, and with the well-decomposed refuse layer transforming most dissolved organic compounds to CO(2), carbonates and methane, it was found that the fresh refuse column could efficiently denitrify the hydrolyzed nitrogen to N(2) gas. The role of the three mentioned units and comments on the design and operation of the proposed system are also discussed.  相似文献   

9.
Long-term biodegradation of MSW in an aerobic landfill bioreactor was monitored as a function of time during 510 days of operation. Operational characteristics such as air importation, temperature and leachate recirculation were monitored. The oxygen utilization rates and biodegradation of organic matter rates showed that aerobic biodegradation was feasible and appropriate to proceed in aerobic landfill bioreactor. Leachate analyses showed that the aerobic bioreactor could remove above 90% of chemical oxygen demand (COD) and close to 100% of biochemical oxygen demand (BOD5) from leachate. Ammonium (NH4+), nitrate (NO3-) and sulphate (SO4(2-)) concentrations of leachate samples were regularly measured. Results suggest that nitrification and denitrification occurred simultaneously, and the increase in nitrate did not reach the levels predicted stoichiometrically, suggesting that other processes were occurring. Leachate recirculation reduced the concentrations of heavy metals because of the effect of the high pH of the leachate, causing heavy metals to be retained by processes such as sorption on MSW, carbonate precipitation, and hydroxide precipitation. Furthermore, the compost derived from the aerobic biodegradation of the organic matter of MSW may be considered as soil improvement in the agricultural plant production. Bio-essays indicated that the ecotoxicity of leachate from the aerobic bioreactor was not toxic at the end of the experiment. Finally, after 510 days of degradation, waste settlement reached 26% mainly due to the compost of the organic matter.  相似文献   

10.
Recycling of aged refuse from a closed landfill.   总被引:3,自引:0,他引:3  
In this study, refuse excavated from a typical refuse landfill in Shanghai after 8-10 years of placement was characterized in terms of particle size, total nitrogen, total phosphorus, and biodegradable matter. The refuse contained a large and diverse population of micro-organisms with a high capacity for decomposing refractory organic matter present in some wastewaters, including leachate. It was found that the aged refuse was quite stable after about a decade of decomposition in the warm, humid climate of southern China. The fine fractions resembled and had the properties of black soil, a medium that is suitable for green construction, organic fertilizer, or as bioreactor media for biological treatment of organic wastewaters. Excavation of the aged refuse would make about 50% of the space available for fresh refuse. The plastics, glass, textiles, and cans can be readily mechanically separated and recycled after cleaning. It is estimated that at least 200 millions tonnes of such aged refuse are available in China alone, and at least 10 times that much is buried worldwide. Hence, the evaluation of mined landfill waste and consideration of its potential uses is of great significance.  相似文献   

11.
Leachate was collected from an anaerobic lagoon at Shanghai Laogang refuse landfill, the largest landfill in China, and the sample was separated into six fractions using micro-filtration membranes, followed by ultra-filtration membranes. Several parameters of the samples were measured, including chemical oxygen demand (COD), total organic carbon (TOC), total solids (TS), pH, total phosphate (TP), total nitrogen (TN), fixed solids (FS), NH4+, orthophosphate, color, turbidity, and conductivity. These parameters were then quantitatively correlated with the molecular weight cutoff of the membrane used. Organic matter in the dissolved fraction (MW<1kDa) predominated in the leachate, accounting for 65% of TOC. Thermal infrared spectroscopy was used to characterize the filter residues. Asymmetric and symmetric stretching of methyl and methylene groups, and of functional groups containing nitrogen and oxygen atoms, were observed. In addition, the ability of two different samples to adsorb heavy metals was tested. Cu2+ was chosen as the representative heavy metal in this study, and the samples were soil; aged refuse, which had spent 8 years in a conventional sanitary landfill; and samples of soil and aged refuse treated for 48h with leachate in the ratio of 5g of sample per 50ml of leachate. Cu2+ uptake by the raw soil was approximately 4.60microg/g, while uptake by the leachate-contacted soil and leachate-contacted aged refuse were 5.66 and 5.11microg/g, respectively. These results show that the organic matter in the leachate enhanced the capacity of aqueous solutions to adsorb Cu2+.  相似文献   

12.
In Europe, the use of direct methods using lysimeters for measuring water and solute flow in soils increased in recent years. Large weighable lysimeters are best suitable for obtaining reliable data about seepage water quantity and quality. Field lysimeters – lysimeters built in directly in agriculturally used areas – of high technical standard allow a precise determination of the influence of different cropping systems on groundwater quality. They combine the advantages of true field conditions and laboratory possibilities of varying parameters, handling and maintenance. Due to the specific needs of each application the instrumentation varies. Based on general remarks on the advantages of precise weighing lysimeters four standardized lysimeter configurations are presented. Beside the specific needs of design and setup of lysimeter stations, there is need to define general requirements to enable comparable results based on standardized basic design and to reduce individual mistakes.  相似文献   

13.
采用微电解—Fenton试剂氧化—A/O组合工艺处理高浓度制药废水。实验结果表明:经微电解—Fenton试剂氧化工艺预处理后,COD去除率可达50%~60%,BOD5/COD提高到0.3以上;预处理后的废水与清洗废水和生活污水混合,采用生化法进一步处理,出水COD小于100 mg/L,BOD5小于20 mg/L,ρ(NH3-N)小于50 mg/L,SS小于70 mg/L,满足GB 8978—1996《污水综合排放标准》中的三级排放标准。  相似文献   

14.
This study investigated the electrochemical oxidation of stabilized leachate from Pulau Burung semi-aerobic sanitary landfill by conducting laboratory experiments with sodium sulfate Na2SO4 (as electrolyte) and graphite carbon electrodes. The control parameters were influent COD, current density and reaction time, while the responses were BOD removal, COD removal, BOD:COD ratio, color and pH. Na2SO4 concentration was 1 g/L. Experiments were conducted based on a three-level factorial design and response surface methodology (RSM) was used to analyze the results. The optimum conditions were obtained as 1414 mg/L influent COD concentration, 79.9 mA/cm2 current density and 4 h reaction time. This resulted in 70% BOD removal, 68% COD removal, 84% color removal, 0.04 BOD/COD ratio and 9.1 pH. Electrochemical treatment using graphite carbon electrode was found to be effective in BOD, COD and color removal but was not effective in increasing the BOD/COD ratio or enhancing biodegradability of the leachate. The color intensity of the treated samples increased at low influent COD and high current density due to corrosion of electrode material.  相似文献   

15.
Open waste dump systems are still widely used in Indonesia. The Jatibarang landfill receives 650-700 tons of municipal waste per day from the city of Semarang, Central Java. Some of the leachate from the landfill flows via several natural and collection ponds to a nearby river. The objectives of the study were to identify seasonal landfill leachate characteristics in this surface water and to determine the occurrence of natural attenuation, in particular the potential for biodegradation, along the flow path. Monthly measurements of general landfill leachate parameters, organic matter-related factors and redox-related components revealed that leachate composition was influenced by seasonal precipitation. In the dry season, electrical conductivity and concentrations of BOD, COD, N-organic matter, ammonia, sulphate and calcium were significantly higher (1.1-2.3 fold) than during the wet season. Dilution was the major natural attenuation process acting on leachate. Heavy metals had the highest impact on river water quality. Between the landfill and the river, a fivefold dilution occurred during the dry season due to active springwater infiltration, while rainwater led to a twofold dilution in the wet season. Residence time of leachate in the surface leachate collection system was less than 70 days. Field measurements and laboratory experiments showed that during this period hardly any biodegradation of organic matter and ammonia occurred (less than 25%). However, the potential for biodegradation of organic matter and ammonia was clearly revealed during 700 days of incubation of leachate in the laboratory (over 65%). If the residence time of leachate discharge can be increased to allow for biodegradation processes and precipitation reactions, the polluting effects of leachate on the river can be diminished.  相似文献   

16.
Suspended solids, colour and chemical oxygen demand (COD) are among the main pollutants in landfill leachate. Application of physical or biological processes alone is normally not sufficient to remove these constituents, especially for leachate with a lower biochemical oxygen demand (BOD)/ COD ratio. The main objective of this research was to investigate the efficiency of coagulation and flocculation processes for removing suspended solids, colour and COD from leachate produced in a semi-aerobic landfill in Penang, Malaysia. A 12-month characterization study of the leachate indicated that it had a mean annual BOD/COD ratio of 0.15 and was partially stabilized, with little further biological degradation likely to occur. Particle size analysis of the raw leachate indicated that its 50th percentile (d50) was 11.68 microm. Three types of coagulants were examined in bench scale jar test studies: aluminium sulphate (alum), ferric chloride (FeCl3) and ferrous sulphate (FeSO4). The effects of agitation speed, settling time, pH, coagulant dosages and temperature were examined. At 300 rpm of rapid mixing, 50 rpm of slow mixing, and 60 min settling time, higher removals of suspended solids (over 95%), colour (90%) and COD (43%) were achieved at pH 4 and 12. FeCl3 was found to be superior to other coagulants tested. At pH 4 and 12, fair removal of suspended solids was observed at a reasonably low coagulant dose, i.e., 600 mg L(-1); hHowever, about 2500 mg L(-1) of coagulant was required to achieve good removals at pH 6. Better removals were achieved at higher temperature. The d50 of sludge after coagulation at pH 4 with a 2500 mg L(-1) FeCl3 dose was 60.16 microm, which indicated that the particles had been removed effectively from the leachate. The results indicate that coagulation and flocculation processes can be used effectively in integrated semi-aerobic leachate treatment systems, especially for removing suspended solids, colour and COD.  相似文献   

17.
Ozonation, combined with the Fenton process (O(3)/H(2)O(2)/Fe(2+)), was used to treat matured landfill leachate. The effectiveness of the Fenton molar ratio, Fenton concentration, pH variance, and reaction time were evaluated under optimum operational conditions. The optimum removal values of chemical oxygen demand (COD), color, and NH(3)-N were found to be 65%, 98%, and 12%, respectively, for 90 min of ozonation using a Fenton molar ratio of 1 at a Fenton concentration of 0.05 mol L(-1) (1700 mg/L) H(2)O(2) and 0.05 mol L(-1) (2800 mg/L) Fe(2+) at pH 7. The maximum removal of NH(3)-N was 19% at 150 min. The ozone consumption for COD removal was 0.63 kg O(3)/kg COD. To evaluate the effectiveness, the results obtained in the treatment of stabilized leachate were compared with those obtained from other treatment processes, such as ozone alone, Fenton reaction alone, as well as combined Fenton and ozone. The combined method (i.e., O(3)/H(2)O(2)/Fe(2+)) achieved higher removal efficiencies for COD, color, and NH(3)-N compared with other studied applications.  相似文献   

18.
This study was aimed to investigate the biodegradation characteristics of organic matters in swine carcasses. The lysimeters were simulated with different initial operating conditions: 30 % volumetric moisture content and no sludge addition for lysimeter A (control), 30 % volumetric moisture content and anaerobic sludge addition for lysimeter B, and 40 % volumetric moisture content and anaerobic sludge addition for lysimeter C. The degradation efficiency (18.4 %) of lysimeter B was higher than that (15.2 %) of lysimeter A due to anaerobic sludge addition. Lysimeter B showed higher CH4 yield (15.6 L/kg VS) and CH4 production rate (0.41 L/kg VS days) compared to lysimeter A by 31 % and 14 %, respectively. In addition, the degradation efficiency improved from 18.4 % (lysimeter B) to 26.3 % (lysimeter C) by increasing volumetric moisture content. The CH4 yield (22.9 L/kg VS) and CH4 production rate (0.68 L/kg VS days) of lysimeter C were higher than those of lysimeter B, respectively. Total organic carbon (TOC) removed in lysimeter C was converted to leachate (20.3 %) and gas (6.0 %), whose values were higher than those of lysimeter A and B. These results demonstrated that the proper control of initial operating conditions could accelerate the anaerobic degradation of organic matters in swine carcasses.  相似文献   

19.
Non-hazardous industrial process wastes are receiving increased interest from landfill owners, especially with respect to bioreactor operation. These wastes could benefit bioreactors as they represent sources of liquid, nutrients, and/or substrate as well as revenue. However, landfill operators should exercise caution in accepting these wastes, as some could have detrimental effects on refuse decomposition. In this research, the use of laboratory-scale tests to evaluate the effect of one such waste on refuse decomposition is demonstrated. The waste evaluated, referred to as burnt sugar, is an acidic byproduct of corn-based polylactic acid production and represents a source of readily-biodegradable carbon. Lactic acid was the primary constituent of the BS at 0.73 g/g and the COD was measured at 1230 mg COD/g. Testing protocols were adapted to address the specific concerns surrounding the material. Abiotic dissolution tests conducted at mesophilic temperatures indicated that the majority of the waste dissolved into leachate recirculated over a layer of the waste within several days. Abiotic mixing tests suggested that the waste would acidify refuse to pH 6.41 at a loading of 21.9 g/dry kg refuse. However, in biologically active tests, the refuse was able to convert loadings as high as 196.7 g/dry kg refuse to methane. As the loadings increased toward and beyond this level, pronounced detrimental effects to the refuse ecosystem were observed, including a decrease in pH, accumulation of volatile fatty acids and COD, and lag in methane production. The results suggested that actively decomposing refuse has the potential to attenuate relatively high loading of a rapidly degradable but acidic substrate. Nonetheless, caution in the implementation of a field program to accept rapidly biodegradable acidic wastes is critical.  相似文献   

20.
A combined process comprised of ex-situ nitrification in an aged refuse bioreactor (designated as A bioreactor) and in-situ denitrification in a fresh refuse bioreactor (designated as F bioreactor) was constructed for investigating N2O emission during the stabilization of municipal solid waste (MSW). The results showed that N2O concentration in the F bioreactor varied from undetectable to about 130 ppm, while it was much higher in the A bioreactor with the concentration varying from undetectable to about 900 ppm. The greatly differences of continuous monitoring of N2O emission after leachate cross recirculation in each period were primarily attributed to the stabilization degree of MSW. Moreover, the variation of N2O concentration was closely related to the leachate quality in both bioreactors and it was mainly affected by the COD and COD/TN ratio of leachate from the F bioreactor, as well as the DO, ORP, and NO3?-N of leachate from the A bioreactor.  相似文献   