首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 897 毫秒
1.
Phase change materials (PCMs) that can store and release heat energy over the temperature range from 363 to 393 K are crucial for solar absorption cooling, and it is worthy to seek new solid-liquid PCMs candidates that melt and crystallize in this temperature range. In this paper, (E)-3-m-tolylbut-2-enoic acid (mTBEA) was applied as a PCM candidate. Its thermal energy storage properties and thermal stability were systematically investigated. The results showed that mTBEA melted at 382.9 ± 0.5 K and crystallized at about 364 K, with a melting enthalpy (ΔfusH) of 138.4 ± 6.9 J g?1 and showed good long-term cyclic stability and thermal stability. The supercooling of mTBEA was stabilized at about 20 K, indicating that the conservation condition of melted mTBEA could be simple. In addition, the melted mTBEA could release all the absorbed thermal energy upon crystallizing. Besides, mTBEA exhibited good thermal stability for it to be applied as PCM. Hence, mTBEA is a promising PCM candidate for solar absorption cooling. Furthermore, the heat capacity of mTBEA was measured by modulated temperature differential scanning calorimetry (MTDSC) over the temperature range from 198.15 to 431.15 K, and the molar thermodynamic functions, [HT-H298.15]m and [ST-S298.15]m, were calculated based on the fitted molar heat capacity data.  相似文献   

2.
This paper aims to reveal the heat transfer mechanism of low-temperature phase change material (PCM) and design PCM heat storage device in building heating environment. Firstly, low-temperature binary PCMs of lauric acid and stearic acid are prepared, and their thermal properties are investigated by DSC. Then, shell and tube latent heat thermal energy storage units are conducted, and heat transfer experiments are carried out to analyze the heat transfer mechanism of PCM. The results demonstrate that natural convection plays an important role in heat transfer process, and the heat storage efficiency of PCMs can be significantly enhanced by increasing the fin width and improving the inlet heat transfer fluid (HTF) temperature. Furthermore, some proposals are put forward to guide the design of PCM storage device in building heating environment.  相似文献   

3.
Solar energy is one of the most important renewable energy sources, but it is not available every time and every season. Thus, storing of solar energy is important. One of the popular methods of heat storage is use of phase change materials (PCMs) which have large thermal energy storage capacity. In this study, the heat storage tank in a domestic solar water heating system was chosen as control volume. The experiments were performed in the province of Elaz?g, Turkey, in November when solar radiation was weak due to cloudy sky. The heat storage tank of the system was modified to fill PCM between insulation and hot water part. A few PCMs which are Potassium Fluoride, Lithium Metaborate Dihydrate, Strontium Hydroxide Octahydrate, Barium Hydroxide Octahydrate, Aluminum Ammonium Sulfate, and Sodium Hydrogen Phosphate were analyzed to proper operating conditions using a Differential Scanning Calorimeter (DSC) and the best PCM was obtained with the Aluminum Ammonium Sulfate and Sodium Hydrogen Phosphate mixture. Thus, eutectic PCM was obtained and used in a heat storage tank of the solar water heating system. Energy and exergy analysis of heat storage tank was performed with and without the PCM. Energy and exergy analysis has shown that the heat storage tank with the PCM is more efficient than without the PCM and the maximum exergy efficiency was obtained as 22% with the heat storage tank with the PCM.  相似文献   

4.
Electrospun cellulose acetate (CA) nanofibrous mats incorporated with capric acid was studied to fabricate form-stable phase change materials (PCMs) for storing/retrieving thermal energy. Electrospun CA nanofibrous mats with different porous structures and specific surface areas were firstly prepared through regulating the volume ratio of mixture solvent of acetone/dichloromethane (DCM). Effects of different volume ratio of mixture solvent and mat thickness on the morphological structure, specific surface area, and absorption capacity of CA nanofibrous mats were systematically investigated. The results indicated that CA nanofibrous mats were highly porous on the surface; hence, they were capable of absorbing a large amount of capric acid. The maximum absorption capacity of CA mats via electrospinning with volume ratio of acetone/DCM being 5/5 was ~95.8 wt%, due to its higher specific surface area of ~17.1 m2/g. The specific surface area and capric acid absorption capacity of CA nanofibrous mats increased with the increases of mat thickness. As the thickness of nanofibrous mats increased from 10 to 85 μm, the corresponding specific surface area and capric acid absorption capacity of mats increased respectively from 7.2 to 29.0 m2/g and 92.1 to 98.5%. Morphological structures, as well as the properties of thermal energy storage and thermal insulation of the fabricated form-stable PCMs, were studied by scanning electron microscopy, differential scanning calorimetry, and measurement of freezing times, respectively. The results indicated that the resulting form-stable PCMs could well maintain their phase transition characteristics and demonstrated great thermal energy storage capability and temperature regulation ability.  相似文献   

5.
ABSTRACT

Aquaculture raceway temperature has a direct impact on the aquatic specie being reared. In regions that undergo significant seasonal temperature variations, the thermal management of the raceway temperature becomes a challenge, directly impacting the production yield. This study investigates a novel approach to regulate the raceway temperature in a sustainable way by utilizing geothermal energy. A numerical energy model was developed to simulate heat transfer in a geothermal system encompassing both the individual borehole heat exchangers and their thermal interactions. Simulations were conducted for different configurations of the geothermal system over a complete seasonal cycle. Results show that flow rate, number of boreholes and the borehole spacing influence the temperature of the fluid at the raceway inlet. An increase in the number of boreholes provided better thermal regulation but an increase in the flow rate through the boreholes provided less thermal regulation. A borehole spacing of 6 m was found to be appropriate to reduce thermal interference. It was also observed that an increase in the fraction of the fluid passed through the geothermal system enhances the overall thermal regulation, with higher thermal regulation at lower flow rates. Results show that when 100% of the fluid passed through a 64 boreholes geothermal system, the average regulated raceway inlet temperature was 23% higher in winter months and 16% lower in summer months at the flow rate of 21.5 L/s compared to than at 43 L/s.  相似文献   

6.
ABSTRACT

Large-scale greenhouse solar dryers have been used for drying various products and this type of dryer is usually equipped with LPG burner as auxiliary heater, which creates more operating cost. To overcome this problem, phase change material (PCM) thermal storage was proposed to substitute for the LPG burner. In this work, the performance of a large-scale greenhouse solar dryer integrated with a PCM as a latent heat storage for drying of chili was investigated. Experimental studies were conducted to compare the performance of this dryer with that of another large-scale greenhouse solar dryer without the PCM thermal storage and open sun drying. Chili with an initial moisture content of 74.7% (w.b.) was dried to a final moisture content of 10.0% (w.b.) in 2.5 days, 3.5 days, and 11 days using the solar dryer integrated with the PCM thermal storage, the solar dryer without the PCM thermal storage and the open sun drying, respectively. The performance of the solar dryer integrated with the PCM thermal storage was also evaluated using exergy analysis. The exergy efficiency of the drying room of the solar dryer integrated with the PCM thermal storage and the solar dryer without the PCM thermal storage for drying of chili was found to be 13.1% and 11.4%, respectively and the thermal storage helps to dry chili during adverse weather conditions. The results of exergy analysis implied that the exergy losses from the dryer with the PCM should be reduced.  相似文献   

7.
ABSTRACT

Cold chain industry has a vast potential for waste heat recovery. It is a matter of importance for energy efficiency point of view, as global energy demand is increasing day by day. Ample amount of low-grade energy is either unutilized or underutilized. The heat rejected by a Heat pump or refrigeration system emerged as a promising solution for dehydration by utilizing low-grade waste heat despite higher investment. As compared to solar drying technology, heat pump drying evolved as a reliable method regarding better process control, energy efficiency, and quality of the product to be dried. Energy utilized through the refrigeration system’s waste/exhaust heat recovery in combination with or without renewable energy source enhances the overall efficiency of the system and also reduces the cost. This useful review investigated and compared the research findings of waste heat utilization through heat pump and from condenser of refrigeration system on laboratory, pilot as well as industrial scale for drying of various fruits, vegetables, and agro products. Various drying parameters like drying rate, moisture content, Specific Moisture Extraction Rate (SMER), Coefficient of Performance (COP), Exergy efficiency, and temperature as well as humidity conditions inside the drying chamber were also reviewed to promote the technological advancement of energy utilization by commercial cold storage waste heat recovery.  相似文献   

8.
To improve the competiveness in the energy market, it is necessary that the wind power plants provide guaranteed power generation, although, it is not possible to forecast power availability from wind power plant accurately. This paper presents a stochastic model and solution technique for the combined operation of wind and pumped storage power plants to improve the power availability and increasing the profit considering uncertainties of wind power generation. In this model, uncertainties in wind data have been forecasted for grid connected day-ahead market using Weibull distribution model. The imbalances in the forecasted wind data and the market demand have been reduced by operating the pumped storage power plant. In this stochastic mixed integer problem, pumped storage plant can take the supply either from the grid or from the wind power plant for the pumping operation to store the energy in order to utilize this energy during peak hours for increasing the overall revenue. The reliability of the pumped storage is improved by replacing the conventional unit with the adjustable speed type pumped storage unit. In order to prove the optimality of the solution, two case studies were considered. In case studyI, scheduling is provided by operating the conventional pumped storage unit, whereas in case studyII, adjustable speed pumped storage unit has been used. It has been found that the adjustable speed pumped storage unit has further reduced the imbalance between generated power and demand. The complete approach has been formulated and implemented using AMPL software.  相似文献   

9.

Each plant has its own optimal drying temperature, especially for the medicinal herbs, because they are sensitive to heat. If the drying temperature becomes more than the optimal value, some chemical reactions will occur and influence the quality of the dried herb, such as color, taste, and aroma. While if the drying temperature becomes lower than the optimal value, the drying process will slow down, and consequently an expected degradation in the quality of the herb may occur, due to insects and fungi infestation which increase in moist conditions. This paper presents a new temperature control technique for a medicinal herb dryer system. The technique fixes the drying temperature of the medicinal herbs at 40°C, even in cases of rapidly changing atmospheric conditions. The control of the dryer temperature is achieved through using the proportional integral (PI) controller. The designed dryer contains two systems, which are the thermal and the electrical systems. The thermal system is designed to heat the drying air by using solar energy and bio-gas fuel. Whereas the electrical system, which contains a photovoltaic (PV) modules and a battery, is designed to supply the different electrical loads of the dryer system. The control technique is investigated through simulation work by using MATLAB-SIMULINK. The simulation results indicate the high capability of the proposed technique in controlling the drying temperature, even in cases of rapidly changing atmospheric conditions.  相似文献   

10.
ABSTRACT

Refrigerant pressure drop and temperature change in pipes are normally ignored in the thermodynamic analysis of traditional vehicle air conditioning system, this will result in serious errors. In this Paper, pressure drop and temperature difference are simulated in different pipes of electric vehicle (EV) heat pump system to analysis the effects of pipes in the actual EV heat pump system. The results indicate that the greater the mass flow, the faster pressure drop increases, the temperature difference decreases. Pressure drop of saturated liquid refrigerant is smaller than that of saturated gas refrigerant at the same saturation pressure and mass flow rate. The higher the refrigerant pressure (no phase change), the slower pressure drop decreases, the faster the temperature difference decreases. Pressure drop decreases with the increment of bending angle of the pipe. For EV heat pump system, suitable valves and less branches are helpful for energy saving of the system. Shortening the pipe between compressor and condenser can reduce temperature change obviously. Pressure drop per unit length in the pipe between evaporator and compressor is large especially in heating mode because of lower refrigerant density. It even reaches to over 100 times of that in the pipe between condenser and throttle valve in heating mode and has negative effects on the performance of the system. If the evaporator is closer to the compressor and the number of branches is less, then pressure drop will decrease a lot, which will be advantageous for energy saving of the heat pump system.  相似文献   

11.
Absorption by chemical solvents combined with CO2 long-term storage appears to offer interesting and commercial applicable CO2 capture technology. However one of the main disadvantages is related to the large quantities of heat required to regenerate the amine solvent that means an important power plant efficiency penalty. Different studies have analyzed alternatives to reduce the heat duty on the reboiler and the thermal integration requirements on existing power cycles. In these studies integration principles have been well set up, but there is a lack of information about how to achieve an integrated design and the thermal balances of the modified cycle flowsheet. This paper proposes and provides details about a set of modifications of a supercritical steam cycle to overcome the energy requirements through energetic integration with the aim of reducing the efficiency and power output penalty associated with CO2 capture process. Modifications include a new designed low-pressure heater flowsheet to take advantage of the CO2 compression cooling for postcombustion systems and integration of amine reboiler into a steam cycle. It has been carried out several simulations in order to obtain power plant performance depending on sorbent regeneration requirements.  相似文献   

12.
With the trend towards increasing the speed of processors in smaller sized of computers, there has been considerable interest in heat sink technologies with higher levels of performance and further miniaturization. This work addresses the fundamental heat transfer augmentation question of how to design a copper-based heat sink, when the overall dimensions of the bottom plate or fan are specified. A three-dimensional finite-volume model has been developed and applied to investigate flow and conjugate heat transfer in the copper-based heat sink. The model was produced with the commercial program FLUENT, which allows this nonlinear, highly turbulent problem to be simulated using the k-ε turbulence model. The theoretical model developed is validated by comparing the model predictions with available experimental data. The thermal performance and temperature distribution for the heat sink were analyzed and a procedure for optimizing the geometrical design parameters based on less space occupation and more efficient heat transfer coefficient is presented. Several design examples with different types of cooling methods and manufacturing processes have been analyzed. The reliability and effectiveness in heat spreading of those has been compared. It has been shown that the copper-based heat sink with louvered fins (case No.3) has an optimum design configuration.  相似文献   

13.
ABSTRACT

Thermal potential for cooling and heating can be achieved by new configuration of earth–air heat exchanger (EAHE). This paper presents a numerical investigation of thermal performance of a spiral-shaped configuration of EAHE intended for the summer cooling in hot and arid regions of Algeria. A commercial finite volume software (ANSYS FLUENT) has been used to carry out the transient three-dimensional simulations and the obtained results have been validated using the experimental and numerical data obtained from the literature. The agreement between our simulation results and those from literature is very satisfactory. A parametric analysis of the new geometry of (EAHE) has been performed to investigate the effect of pitch, depth, pipe length and of the flow velocity on the outlet air temperature and the EAHE’s mean efficiency as well as its coefficient of performance (COP). It has been shown that when the pitch space varies between 0.2 and 2 m the difference of outlet air temperature increases by 6 °C. When the air velocity increases from 2 to 5 m/s the mean efficiency decreases from 60 % to 33 % and the COP of the EAHE decreases from 2.84 to 0.46.  相似文献   

14.
Experiments are described to investigate the thermal performance of a discharging heat exchanger for a small storage tank filled with oil. Experimental results are presented in terms of the discharging energy rates (power) and the discharging exergy rates for low (~4 ml/s) and high discharging flow rates (~8 ml/s). Water heating energy rates, which are respectively maximized at approximately 600 W and 1200 W at low and high flow-rate discharging, are found to be higher than the discharging energy rates, which are respectively maximized at 450 W and 900 W. These results indicate that the energy rates do not accurately evaluate the thermal performance of the discharging heat exchanger since the energy heating rate of the water is greater than that for the oil that heats it, which is thermodynamically inconsistent. The energy rates should thus be used with caution when the thermal performance of the heat exchanger is evaluated. Water heating exergy rates, which are respectively maximized at approximately 45 W and 130 W at low and high flow-rate discharging, are generally smaller than the discharging exergy rates, which are respectively maximized at 65 W and 170 W. Exergy rate results are thus more consistent in the physical process of water heating, and an exergy factor is suggested as a proper measure for evaluating the performance of the discharging heat exchanger. The maximum value of the exergy factor is found to increase from 0.15 at low flow rates to a maximum value of approximately 0.19 at high flow rates. This implies that to extract more energy from a storage tank to a discharging heat exchanger, the flow rate has to be high, which is consistent with the physical process of heating water faster to higher temperatures. The exergy factor can thus be used as a design parameter for discharging heat exchangers.  相似文献   

15.
ABSTRACT

Al2O3/water nanofluid has been numerically examined for the first time with different nanoparticle shapes including, cylindrical, blade, brick, platelet and spherical, on the flat and triangular-corrugated impinging surfaces. The volume fractions of 1.0%, 2.0% and 3.0% nanoparticles have been used. The Reynolds number is between 100–500 depending on the slot diameter. The finite volume method is utilized to determine the governing equations. The study is analyzed to determine how the flow features, heat transfer features and entropy production were affected by the diversity of nanoparticle shape, nanoparticle volume fraction, and shape of impinging surface. Darcy friction factor and Nusselt number are studied in detail for different conditions. The temperature contours are presented in the case of different nanoparticle volume fractions, nanoparticle shapes and both impinging surfaces. The results of the study suggest that the nanoparticle shape of the platelet shows the highest heat transfer development due to the thinner thermal boundary layer. Heat transfer augments with increasing volume fraction of nanoparticles. In addition, the study is consistent with the results of the literature on heat transfer and flow properties.  相似文献   

16.
Industrial waste is a good resource from the viewpoint of efficient waste management. The vital need for energy utilization and environmental protection mean it is of interest to develop circulating fluidized bed combustion (CFBC) to burn solid wastes with low pollutant emissions. The paper presents some explanatory studies on waste-to-energy in a pilot scale CFCB facility. A series of combustion/incineration tests have been carried out for the industrial wastes: petroleum coke, waste tire and sludge cakes with various moisture contents. It seems that the CFBC has feed flexibility without modifying heat transfer equipments for energy recovery. In addition, the results of experimental tests demonstrate that gas emissions from waste incineration in CFBC can be well controlled under local regulation limits.At normal operation temperature in CFBC (approx. 800°C), the heat transfer coefficient between bulk bed and bed wall is on the order of 102 W/m C, which is useful to estimate the energy recovery of waste combustion by CFBC. A practical and simple guide is proposed to estimate the energy recovery from waste combustion by CFBC, and to find maximum allowable moisture content of waste if there is to be any energy recovery without auxiliary fuel.  相似文献   

17.
In this study, the rice bran oil (RBO) has been converted into methyl ester with an aid of transesterification reaction. Chemically, transesterification means conversion of triglyceride molecule or a complex fatty acid into alcohol and ester by removing the glycerin and neutralizing the free fatty acids. The B20 blend samples [80% diesel + 20% biodiesel] were prepared for each methyl ester obtained from RBO and then the cerium oxide (CeO2) nanoparticles were added to the each B20 blend samples at a dosage of 50 ppm and 100 ppm with an aid of ultrasonicator. Moreover, in the absence of any engine modifications, the performance and emission characteristics of those blend samples have been investigated from the experimentally measured values such as density, viscosity, cloud point, pour point, and calorific value while the engine performance was also analyzed through the parameters like exhaust gas temperature (EGT), brake specific fuel consumption (BSFC), brake thermal efficiency (BTE), exhaust emission of carbon monoxide (CO), hydrocarbon (HC), and nitrogen oxide (NOx). The experimental results reveal that the use of CeO2 blended biodiesel in diesel engine has exhibited good improvement in performance characteristic and reduction in exhaust emissions.  相似文献   

18.
ABSTRACT: Thermal energy storage involves the capture and storage of thermal energy (either heat or chill) during one time period for use at a later period. Storage of thermal energy in aquifers on a seasonal basis is one promising application of the technology that has been implemented in several foreign countries and is currently undergoing field testing in the U.S. Potential developers of aquifer thermal energy storage projects will face a number of regulatory requirements at the federal, state, and local level of government. These can include meeting: (1) surface land and ground water use restrictions, (2) regulations relating to withdrawal of ground water, and (3) requirements for reinjecting thermally altered ground waters. Separate permits for ground water withdrawal and reinjection may be required. The permit process is likely to involve opportunities for public comment and may involve contested proceedings.  相似文献   

19.
Abstract

In this work, low temperature geothermal district heating systems with heat pumps have been studied and compared with fuel-oil boiler heating systems for intermittent and continuous regimes according to the optimum indoor air temperature and operational cost. Izmir Institute of Technology (IZTECH) Campus is taken as a case study. Various heat pump and boiler configurations are studied to meet required duty. Operational cost analysis for each alternative is conducted. According to the results, for IZTECH Campus the best alternative, which gives the optimum indoor air temperature and the lowest operational cost, is heat pump continuous regime.  相似文献   

20.
ABSTRACT

According to the structure of photovoltaic/phase change material (PV/PCM), the mechanism of internal heat transfer, transmission, storage, and temperature control is analyzed, and a two-dimensional finite element analysis model of PV/PCM structure is established. This study is carried out on the effect of PCM thermal conductivity on internal temperature distribution characteristics of PV/PCM and temperature control characteristics of solar cells. The results show that the increase in thermal conductivity of PCM can prolong the temperature control time of solar cell in PV/PCM system, for example, when the thermal conductivity is increased from 0.2 W/(m·K) to1.5 W/(m·K) under a thickness of 4 cm, the duration when PV/PCM solar cell temperature is controlled below 40°C and extended from 52 min to 184 min. In addition, PV/PCM experimental prototypes are designed with the LA-SA-EG composite PCM peak melting point of 46°C and thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K), respectively. The results indicate that compared with PCM-free solar cells, the maximum temperature of PV/PCM prototype solar cells with thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K) is reduced by 10.8°C and 4.6°C, respectively, with average output power increased by 4.1% and 2.2%, respectively, under simulated light sources. Under natural light conditions, the average output power is increased by 6.9% and 4.3%, respectively. The results provide theoretical and experimental basis for the optimization of PV/PCM design by changing the thermal conductivity of PCM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号