Measurements were made of radon levels in 165 randomly selected homes in Cumberland County, PA during Winter 1984–1985. The average and mean levels were found to be 9.1 ± 0.7 pCi/L and 6.3 ± 0.5 pCi/L, respectively, many times normally encountered levels. Average and mean radon levels are reported vs. various house characteristics.  相似文献   

2.
Radon and gamma dose rate measurements were performed in 512 schools in 8 of the 13 regions of Greece. The distribution of radon concentration was well described by a lognormal distribution. Most (86%) of the radon concentrations were between 60 and 250 Bq m−3 with a most probable value of 135 Bq m−3. The arithmetic and geometric means of the radon concentration are 149 Bq m−3 and 126 Bq m−3 respectively. The maximum measured radon gas concentration was 958 Bq m−3. As expected, no correlation between radon gas concentration and indoor gamma dose rate was observed. However, if only mean values for each region are considered, a linear correlation between radon gas concentration and gamma dose rate is apparent. Despite the fact that the results of radon concentration in schools cannot be applied directly for the estimation of radon concentration in homes, the results of the present survey indicate that it is desirable to perform an extended survey of indoor radon in homes for at least one region in Northern Greece.  相似文献   

3.
The expectation of elevated 222Rn levels in modern homes that have low air interchange rates with the outdoor air caused us to survey both solar and conventional homes in northeastern New York State. As a group, homes that are more airtight have three times the 222Rn levels of the conventional homes; they have other specific problems that are introduced or exaggerated by modern construction. For example, the highest two levels of radon in the solar homes give doses over 30 years that are known to produce lung cancer in 1% of uranium miners. Summer readings in more than one-half of the cases are different from winter ones by a factor of two or more, so that year-round measurements are necessary for precise dosimetry. The track-etching technique is ideally suited for such measurements. Radon emanation measurements on soils and sand demonstrate a considerable variety of release rates.  相似文献   

4.
Bulk deposition samples were collected simultaneously from two Greek cities, Patras and Megalopolis, with different emission sources of natural radioactivity, on a monthly basis, during a whole year. Gross beta-activity and 238U- and 232Th-activities were determined in a total of 95 samples of deposited dust. The results were statistically analyzed in order to determine the natural radioactivity levels and their variations in the above cities. No significant difference was found in deposited dust amount between the two cities, while the values of gross beta-, 238U- and 232Th-activities were about 3, 71 and 4 times higher in Megalopolis than in Patras, respectively. This was attributed to the operation of lignite power plants A and B in the vicinity of the city of Megalopolis, while natural radioactivity concentrations in Patras' fallout samples were of natural sources.  相似文献   

5.
In the beginning of 1990s within the framework of a national radon survey of more than 1500 points, radon measurements were performed in more than 100 houses located in Galicia region, in the Northwest area of Spain. The houses were randomly selected only bearing in mind general geological aspects of the region. Subsequently, a nationwide project called MARNA dealt with external gamma radiation measurements in order to draw a Spanish natural radiation map. The comparison in Galicia between these estimations and the indoor radon levels previously obtained showed good agreement. With the purpose of getting a confirmation of this relationship and also of creating a radon map of the zone, a new set of measurements were carried out in 2005. A total of 300 external gamma radiation measurements were carried out as well as 300 measurements of (226)Ra, (232)Th and (40)K content in soil. Concerning radon, 300 1-m-depth radon measurements in soil were performed, and indoor radon concentration was determined in a total of 600 dwellings. Radon content in soil gave more accurate indoor radon predictions than external gamma radiation or (226)Ra concentration in soil.  相似文献   

6.
Significantly elevated radon concentrations were found in several adjacent houses in Clinton, New Jersey. The United States Environmental Protection Agency screened 56 of the houses and selected 10 for demonstration of radon-reduction techniques. Each of the 10 houses received an intensive radon diagnostic evaluation before a house-specific radon reduction plan was developed. Depressurization effects caused by temperature differentials and the operation of mechanical equipment were quantified. Before and after radon reduction plans were implemented, radon concentrations were determined by charcoal canisters and continuous radon monitors. A variety of sealing and subslab depressurization techniques were applied to the 10 houses. Radon concentrations were reduced by over 95% in all 10 houses. The cost of applying radon reduction techniques ranged from $1500 to $8500 per house. House construction characteristics were described which contributed to the high cost of radon reduction. In summary, the 10-house radon reduction demonstration in Clinton, New Jersey was successful in showing homeowners with similar house types some effective ways of reducing radon concentrations.  相似文献   

7.
Surficial and subsurficial sediment samples derived from gravity cores, selected from the harbour of Patras, Greece, were analyzed for grain size, water content, bulk density, specific gravity, organic carbon content and specific activities of natural radionuclides and (137)Cs. The specific activities of (232)Th, (226)Ra, (40)K and (137)Cs were measured radiometrically. The radionuclides (238)U and (232)Th were also analyzed using the INAA. The differences found between the specific activities of the natural radionuclides measured by the two methods are of no statistical significance. The sediment cores selection was based on a detailed bathymetric and marine seismic survey. Through the study of the detailed bathymetric map and the seismic profiles it was shown that ship traffic is highly influential to the harbour bathymetry. The granulometric and geotechnical properties of the sediments and therefore the specific activities of the natural radionuclides and (137)Cs seem to be controlled by the ship traffic. Relationship between radionuclide activity concentrations and granulometric/geotechnical parameters was defined after the treatment of all the analyses using R-mode factor analysis. The natural radionuclide activities are related to the fine fraction and bulk density of the sediments, while (137)Cs is mainly influenced by the organic carbon content. In addition, (238)U and (226)Ra seem to be in close relation with the heavy minerals fraction in coarse-grained sediments with high specific gravity.  相似文献   

8.
The indoor radon (222Rn) activity concentration was measured between January and June in the schools of two geothermal areas in Tuscany, central Italy. One of these areas (the Larderello area) is characterized by a large number of geothermal power plants, covering about 9% of the world’s geothermal power production. In contrast, the other area, Monte Pisano, has not any such facilities. About 250 measurements were made using track etch detectors. Only a slight difference in the concentrations between the two major sampling areas (98 Bq m−3 for Larderello area and 43 Bq m−3 for Monte Pisano area) was found, and this was related to different geological characteristics of the ground and not the presence of the geothermal plants. The measured radon concentrations were always well below the intervention levels in both areas, and health risks for students and personnel in the examined schools were excluded.  相似文献   

9.
Results of indoor gamma radiation and radon measurements in 95 wooden dwellings located in a Norwegian thorium-rich carbonatite area using thermoluminescent dosemeters and CR-39 alpha track detectors, respectively, are reported together with a thorough analysis of the indoor data with regard to geological factors. Slightly enhanced radium levels and thorium concentrations of several thousands Bq kg(-1) in the carbonatites were found to cause elevated indoor radon-222 levels and the highest indoor gamma dose rates ever reported from wooden houses in Norway. An arithmetic mean indoor gamma dose rate of 200 nGy h(-1) and a maximum of 620 nGy h(-1) were obtained for the group of dwellings located directly on the most thorium-rich bedrock.  相似文献   

10.
In this work we present the results of a 2-year survey of indoor radon variations in four cities of Lahijan, Ardabil, Sar-Ein and Namin in North and Northwest Iran. We used both passive and active measurements by solid state nuclear track detectors (SSNTDs) with CR-39 polycarbonate and PRASSI Portable radon Gas Surveyor. A total of 1124 samplers in Lahijan, Ardabil, Sar-Ein and Namin were installed. Sampling frequency was seasonal and sampling locations were randomly chosen based on dwelling structures, floors, geological formations, elevation and temperature variation parameters. For quality assurance, 281 active measurements and double sampling were carried out. Based on our results and the results of previous surveys, Ardabil and Lahijan have the second and third highest radon concentration in Iran, respectively (Ramsar is first). The average radon concentration during the year in Lahijan, Ardabil, Sar-Ein and Namin were 163, 240, 160 and 144 Bq/m(3) with medians of 160, 168, 124 and 133 Bq/m(3), respectively. These concentrations give rise to annual effective doses of 3.43 mSv/y for Lahijan and 5.00 mSv/y for Ardabil. The maximum recorded concentration was 2386 Bq/m(3) during winter in Ardabil and the minimum concentration was 55 Bq/m(3) during spring in Lahijan. Relationships between radon concentration and building materials and room ventilation were also studied. The dosimetry calculations showed that these four cities could be categorized as average natural radiation zones. The correlation coefficients relating warm and cold season radon variation data were obtained.  相似文献   

11.
Analysis and modeling of statistical distributions of indoor radon concentration from data valorization to mapping and simulations are critical issues for real decision-making processes. The usual way to model indoor radon concentrations is to assume lognormal distributions of concentrations on a given territory. While these distributions usually model correctly the main body of the data density, they cannot model the extreme values, which are more important for risk assessment. In this paper, global and local indoor radon distributions are modeled using Extreme Value Theory (EVT). Emphasis is put on the tails of the distributions and their deviations from lognormality. The best fits of distributions to real data set density have been computed and goodness of fit with Root Mean Squared Error (RMSE) is evaluated. The results show that EVT performs better than lognormal pdf for real data sets characterized by high indoor radon concentrations.  相似文献   

12.
Indoor radon survey and gamma activity measurements in soil samples were carried out in the Giresun province (Northeastern Turkey). The result of analysis of variance showed a relationship between indoor radon and radium content in soil (R(2)=0.54). It was found that indoor radon activity concentration ranged from 52 to 360 Bq m(-3) with an average value of 130 Bq m(-3). A model built by BEIR VI was used to predict the number of lung cancer deaths due to indoor radon exposure. It was found that indoor radon is responsible for 8% of all lung cancer deaths occurring in this province. (137)Cs activity concentration was measured 21 years after the Chernobyl accident. The results showed that (137)Cs activity concentration ranged from 41 to 1304 Bq kg(-1) with an average value of 307 Bq kg(-1). The indoor radon results and the geology of the studied area were discussed. Annual effective doses to the both radionuclides of natural origin and (137)Cs were estimated.  相似文献   

13.
The authors investigate the effect of filtration and aerosol loading of the air on the level of short-lived air-borne daughter products of radon. By the use of a combination of filtration and aerosol loading, it is possible to shift the partitioning of the radon daughters in the room between the states: airborne, plated-out on the walls, and trapped by filters; the airborne fraction will shift between being attached to aerosol particles and existing as molecular-sized clusters. When the air filtered the equilibrium factor decreases with increasing filtration rate. At high aerosol concentrations the decrease can be explained solely as an effect of the filter removing the daughter products from the air passing through it. As the aerosol production and concentration is lowered, the decrease in equilibrium factor becomes larger. This is caused by an increase in the unattached fraction of the airborne activity and hence in the wall-deposited fraction of the total activity. At a given radon concentration, the dose delivered to a certain portion of the respiratory tract depends not only upon the equilibrium factor but also upon the fraction of, especially, 84218Po in the unattached state. It is further demonstrated that, according to the dose model of Harley and Pasternak, the dose to the basal cells of the epithelium of the bronchii will in general decrease with increasing filtration rate and increase with decreasing aerosol concentration.  相似文献   

14.
Indoor radon distribution of subway stations in a Korean major city   总被引:1,自引:0,他引:1  
The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 ± 14.7 Bq m−3, and the range of values was from 9.4 to 98.2 Bq m−3. The radon concentrations in groundwater (average 31.0 ± 0.8 Bq m−3) were not significantly high in most stations, but the concentration (177.9 ± 2.3 Bq L−1) of one station was over the level of 148 Bq L−1 in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y−1, and 0.02 mSv y−1, respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.  相似文献   

15.
In controlling the natural radiation exposure for the residents of dwellings, it is necessary to determine the levels of natural radioactivity (external exposure) and radon exhalation rate (internal exposure) from building materials. Using a high-resolution gamma ray spectrometry system, the activity concentration of natural radionuclides was measured. The radon exhalation rate was measured by hermetically closing the sample in a container and following the radon activity growth as a function of time. Three different methods were applied in order to find the most appropriate, i.e. that with the less uncertainty for the less exposure time. Typical building materials were analyzed in order to examine the external and internal exposures. In addition, the total annual effective dose was evaluated for the residents of a typical Greek dwelling.  相似文献   

16.
Active soil ventilation techniques have been tested in 26 block-wall basement houses in eastern Pennsylvania with significantly elevated indoor radon concentrations, generally above 740 Bq/m3, and the results indicate that radon levels can be reduced substantially often below the U.S. Environmental Protection Agency (EPA) guideline of 148 Bq/m3, if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: 1) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or 2) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or the soil underneath the slab.  相似文献   

17.
Modeling houses as two coupled chambers, namely, the living area and basement, predicts more accurately the total indoor radon source flux from building materials and geology than a one-chamber model in houses with disparate radon concentrations. Three regional surveys found mean radon concentration ratios between basement and living area to range from 1.4 to 4.2, implying weak interchamber coupling in most cases. The invariability of second-order system parameters under steady infiltration but different initial conditions confirms the adequacy of the two-chamber model. The presence of a characteristic radon source flux was detected within the basements of two houses, in one case across different infiltration, coupling, and initial conditions. One-chamber models fit to two-chamber tracer gas data in one house show a source flux variation of a factor of 6 across changing coupling, while the two-chamber source flux variation was only a factor of 1.5. A substantial fraction of the apparent one-chamber living area source flux in these cases is the variable convective radon flux from the basement. The technique is not sensitive enough to detect living area source fluxes if either the interchamber coupling is strong or if the basement source flux is substantially larger.  相似文献   

18.
This study presents the statistical analysis of PM(10) and PM(2.5) concentrations (measured at a central site, in the Athens area), along with black smoke (BS) data, for a 2-year period. The biennial average concentrations of PM(10) and PM(2.5) were 75 and 40 microg m(-3). The respective average concentration of BS, as estimated by the OECD method, was 108 microg m(-3). Severe exceedances of the PM(10) air quality standards were recorded. The seasonal variation of PM(10) and BS was less pronounced than the variation of PM(2.5), which concentration was elevated by 14.2% during the cold period. Concentrations of all three pollutants were significantly lower during weekends; however, PM(2.5) and BS displayed a more uniform weekly distribution pattern. PM(10) particles were found to be almost equally comprised by PM(2.5) and PM(10-2.5) particles (PM(2.5)/PM(10) ratio=0.53+/-0.09 microg/m(3)). The average PM(10)/BS value was found lower than unity revealing the inappropriateness of the used reflectance conversion method, for the estimation of mass-equivalent BS concentrations, in the study area, where diesel-powered vehicles mainly control emissions of light-absorbing substances. Important reductions in concentrations were observed during days when drivers of diesel-powered taxies and transportation buses went on strike (reaching 40% for BS). Calm wind conditions were found to have an incremental effect on particle concentrations and were also associated with the appearance of persistent episodic events. Increased PM levels were also observed during southern-southwestern wind flows while significantly lower-than-average concentrations were measured during precipitation events. Separate regression analyses were performed for PM(10), PM(2.5) with BS and NO(x) as independent variables, in an attempt to estimate the relative contribution of specific source types (diesel-powered vehicles) to measured particle levels. The contribution of the diesel-exhaust component to PM(10) mass was estimated at 49.9%, while the corresponding contributions to PM(2.5) mass concentrations was 53.8%. These results may have important implications with the oncoming decision of national authorities to allow the purchase of diesel-powered private cars to the residents of the Greater Athens Area, which was forbidden up to this day.  相似文献   

19.
Using high-sensitivity radon ((222)Rn) portable detectors (passive electronic devices of the type RADIM3), the airborne (222)Rn concentration in the interior of various Cypriot buildings and dwellings was measured. For each preselected building and dwelling, a calibrated detector was put into a closed room, and the (222)Rn concentration was registered in sampling intervals of 2 to 4 h for a total counting time of typically 48 h. (222)Rn activity concentrations were found to be in the range of 6.2 to 102.8 Bq m(-3), with an overall arithmetic mean value of (19.3+/-14.7) Bq m(-3). This value is by a factor of two below the world average (population-weighted) value of 39 Bq m(-3). The total annual effective dose equivalent to the Cypriot population was calculated to be between 0.16 and 2.6 mSv with an overall arithmetic mean value of (0.49+/-0.37) mSv.  相似文献   

20.
Geology has been highlighted by a number of authors as a key factor in high indoor radon levels. In the light of this, this study examines the application of seasonal correction factors to indoor radon concentrations in the UK. This practice is based on an extensive database gathered by the National Radiological Protection Board over the years (small-scale surveys began in 1976 and continued with a larger scale survey in 1988) and reflects well known seasonal variations observed in indoor radon levels. However, due to the complexity of underlying geology (the UK arguably has the world's most complex solid and surficial geology over the shortest distances) and considerable variations in permeability of underlying materials it is clear that there are a significant number of occurrences where the application of a seasonal correction factor may give rise to over-estimated or under-estimated radon levels. Therefore, the practice of applying a seasonal correction should be one that is undertaken with caution, or not at all. This work is based on case studies taken from the Northamptonshire region and comparisons made to other permeable geologies in the UK.  相似文献   