首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Experimental study was performed on a single basin active solar distillation system augmented with a solar collector using evacuated solar tubes. Field tests were conducted over several days under the climatic conditions of West Texas to evaluate the effect evacuated solar tubes have on the daily distillate yield rate. To investigate the feasibility of the solar tubes, active and passive solar stills with and without exterior insulation were examined. The maximum daily production rate for the active distillation system using evacuated solar tubes and the passive distillation system was 3.6 and 1.4 kg/m2day, respectively. The results showed the augmentation of the still with evacuated solar tubes increased its production capacity by a factor of 2.63. It also increased the maximum temperature of the water in the still basin by at least 20 °C. Economic analysis shows that it is feasible to use evacuated tubular collector coupled solar still as an alternative means for reclaiming water in farmlands with a payback period of approximately 6 years.  相似文献   

2.
The present study assesses the feasibility of exploiting single- and double-basin solar stills in our daily lives. An investigation is carried out to determine the thermal performance and economic viability of making use of solar stills in water desalination. The climatic conditions of Tehran (35°44?N, 51°30?E) are considered to assess the feasibility of the basins. Transient energy and mass balance equations are utilized for modeling the thermal performance. The equations are solved by using fourth-order Runge–Kutta method in FORTRAN. The daily productivities of single- and double-basin solar stills are found to be 5.22 kg/m2 and 7.73 kg/m2, respectively, while the effect of different water masses (20–100 kg) on the productivity of each system was found to be optimum at 20 kg/m2. The results are compared with experimental work performed under different climatic conditions to examine the validity of the feasibility of basins in general. A life cycle cost analysis performed for Tehran, yields that single- and double-basin solar stills have savings-to-investment ratios of 4.2 and 4.8, respectively, indicating that they are economically feasible.  相似文献   

3.
A new system composed of a sequential flat plate and parabolic dish solar collector was applied to enhance the solar desalination productivity. Heated saline water was desalinated using the evaporation/condensation principle and an effort was made to achieve higher distillate production compared to previous studies. Desalination efficiency values were calculated between 23% and 57%. Maximum desalinated water productions were obtained as 1,038 mL/m2.h in autumn and 1,402 mL/m2.h in summer. The cost of solar desalination system was found as economically feasible with 3 years’ payback period and the produced water cost of 0.014 $/L. Physicochemical analyses revealed that as a result of the desalination process, salinity level decreased from 35.6‰ to 0.0–0.1‰, chloride concentration decreased from 21,407 mg/L to 10 mg/L, and electrical conductivity decreased from 53.1 mS/cm to 0.11 mS/cm.  相似文献   

4.
The performance of the designed tilted wick solar water distillation-cum-drying unit has been tested at water flow rates of 50 and 65 ml/min in the distillation unit. Effect of water flow rates on the heat transfer coefficients of distillation and drying unit for drying ginger has been evaluated. The energy and exergy efficiency of the distillation system have also been evaluated. Average distillates of 2.36 and 2.2 l/m2 were collected from the tilted wick solar still at flow rates of 50 and 65 ml/min, respectively. Large variation in convective and evaporative heat transfer coefficients of distillation unit has been observed at given water flow rates. Water flow rate in the distillation unit significantly affects the performance of the drying unit. Average convective heat transfer coefficients of 6.56 and 3.75 W/m2 oC have been observed for drying ginger at flow rates of 50 and 65 ml/min, respectively. Energy and exergy efficiency of the distillation unit have been found to be nearly 19% and 0.9%, respectively. Experimental uncertainty has also been evaluated for distillation and drying units. The distillate cost for the developed distillation-cum-drying unit is calculated as $0.03729/l along with dried ginger of about 2.5 kg/m2/day.  相似文献   

5.
This paper investigates the prediction of solar radiation model and actual solar energy in Osmaniye, Turkey. Four models were used to estimate using the parameters of sunshine duration and average temperature. In order to obtain the statistical performance analysis of models, the coefficient of determination (R2), mean absolute percentage error (MAPE), mean absolute bias error (MABE), and root mean square error (RMSE) were used. Results obtained from the linear regression using the parameters of sunshine duration and average temperature showed a good prediction of the monthly average daily global solar radiation on a horizontal surface. In order to obtain solar energy, daily and monthly average solar radiation values were calculated from the five minute average recorded values by using meteorological measuring device. As a result of this measurement, the highest monthly and yearly mean solar radiation values were 698 (April in 2013) and 549 (2014 year) W/m2 respectively. On an annual scale the maximum global solar radiation changes from 26.38 MJ/m2/day by June to 19.19 MJ/m2/day by September in 2013. Minimum global solar radiation changes from 14.05 MJ/m2/day by October to 7.20 MJ/m2/day by January in 2013. Yearly average energy potential during the measurement period was 16.53 MJ/m2/day (in 2013). The results show that Osmaniye has a considerable solar energy potential to produce electricity.  相似文献   

6.
Daily global solar radiation on a horizontal surface and duration of sunshine hours have been determined experimentally for five meteorological stations in Saudi Arabia, namely, Abha, Al-Ahsa, Al-Jouf, Al-Qaisumah, and Wadi Al-Dawaser sites. Five-years of data covering 1998–2002 period have been used. Suitable Angstrom models have been developed for the global solar radiation estimation as a function of the sunshine duration for each respective sites. Daily averages of monthly solar PV power outputs have been determined using the Angstrom models developed. The effect of the PV cell temperature on the PV efficiency has been considered in calculating the PV power output. The annual average PV output energy has been discussed in all five sites for small loads. The minimum and maximum monthly average values of the daily global solar radiation are found to be 12.09 MJ/m2/d and 30.42 MJ/m2/d for Al-Qaisumah and Al-Jouf in the months of December June, respectively. Minimum monthly average sunshine hours of 5.89 hr were observed in Al-Qaisumah in December while a maximum of 12.92 hr in Al-Jouf in the month of June. Shortest range of sunshine hours of 7.33–10.12 hr was recorded at Abha station. Minimum monthly average Solar PV power of 1.59 MJ/m2/day was obtained at Al-Qaisumah in the month of December and a maximum of 3.39 MJ/m2/day at Al-Jouf in June. The annual PV energy output was found to be 276.04 kWh/m2, 257.36 kWh/m2, 256.75 kWh/m2, 245.44 kWh/m2, and 270.95 kWh/m2 at Abha, Al-Ahsa, Al-Jouf, Al-Qaisumah, and Wadi Al-Dawaser stations, respectively. It is found that the Abha site yields the highest solar PV energy among the five sites considered.  相似文献   

7.
Abstract

In this article, the convective heat transfer coefficients of various agricultural products were investigated under open sun drying conditions. Data obtained from open sun drying experiments for eight agricultural products, namely, mulberry, strawberry, apple, garlic, potato, pumpkin, eggplant, and onion were used to determine values of convective heat transfer coefficient. The value of convective heat transfer coefficient was determined as 1.861 W/m2°C for mulberry, 6.691 W/m2°C for strawberry, 11.323 W/m2°C for apple, 1.136 W/m2°C for garlic, 8.224 W/m2°C for potato, 8.613 W/m2°C for pumpkin, 6.981 W/m2°C for eggplant, and 6.767 W/m2°C for onion. The experimental error in terms of percent uncertainty was also calculated.  相似文献   

8.
The storage of fresh agricultural products is not easy because of its high moisture. Dehydration is an efficient preservation method. The investigation of drying modeling and transfer characteristics are important for selecting operating conditions and equipment design. The drying behavior of Lactuca sativa slices, with the thickness of 2 mm, was investigated at 60.0–80.0°C and 0.60–1.04 m sec?1 velocity in a convective hot air drier. The mass transfer during the drying process was described using six thin drying models. The convective heat transfer coefficient α and mass transfer coefficient kH were finally calculated. The results showed that the drying process could be separated into three stages including accelerating rate, constant rate, and falling rate period, which was influenced by hot air temperature and velocity, and the Modi?ed Page model agreed well with the experimental data. When the operating temperature was increased from 60.0°C to 80.0°C, α was found increased from 88.07 to 107.93 W·m?2·K?1, and kH increased from 46.32 × 10–3 to 68.04 × 10–3 kg·m?2·sec?1·ΔH?1. With the increase of air velocity from 0.60 to 1.04 m·sec?1, α was increased from 78.85 to 101.35 W·m?2·K?1, and kH was enhanced from 51.78 × 10–3 to 65.85 × 10–3 kg·m?2·sec?1·ΔH?1.  相似文献   

9.
Downward shortwave radiation (DSR) is a highly variable solar source on spatiotemporal basis and essential for energy and agriculture systems, while its calculations are helpful in the environment-related studies, climatology, and monitoring fire risk. Statistical methods developed to extrapolate values of climatic variables and radiation could fail to generate reliable findings of DSR over a complex terrain without considering local topographic factors. In the present study, we proposed an integrative approach of MTCLIM-XL extrapolation with remote sensing (RS) and geographic information system (GIS) to estimate real-time DSR and its spatial potential over surfaces of contrasting elevated sites on a mountainous terrain of Quetta (Pakistan).Based on methodological approach, remote sensing data product of high-resolution DEM (SRTM 30m) was processed to extract topographic data, and meteorological data were obtained from a base site, Subsequently, MTCLIM-XL executed the simulation to calculate the daily-based DSR (W/m2).Spatial distribution of DSR was generated by applying deterministic interpolation with complementing quantification of Hillshade analysis for spatially obstructive surfaces, and resultant spatial hotspot-based potential was assessed on basis of specified threshold level (above 250 W/m2 = 2 kW h/m2) over the specified area. We observed usable potential of DSR at target sites and its spatial distribution during the study period of 2015 to April 2016. Using EUMETSAT CMSAF data as a standard, the validation demonstrates agreeable results of low RMSE and high correlation coefficient values for selected sites, except some sites with relatively high elevations and irregular gradients. Analysis of solar zenith angle to evaluate its inverse relation with increment in DSR values shows agreeable high inverse relation, while the negative trend for only some sites features relatively high rugged topography. In conclusion, MTCLIM-XL with RS and GIS integration manifests as a reliable approach for estimation and spatial potential assessment-based exploration of DSR over complex terrain having no ground data, while prospectively it will complement to the environment-related studies on local to mesoscale.  相似文献   

10.
Alpine grassland of Tibet is a frangible ecosystem in terms of carbon (C) emission. Yak dung is an important resident energy with about 80 % of yak dung combusted for energy in the north Tibetan plateau. This paper investigated the impact of dung combustion on the C cycle of the alpine grassland ecosystem in north Tibet, China. During the growing season of 2011, from a field survey and household questionnaires, the main impacts of dung collection for fuel on the C cycle of the ecosystem were identified. (1) The C sequestration and storage capacity, including the dung-derived C stored in soil and C captured by vegetation, decreased. The net primary production decreased remarkably because of the reduction of dung returned to soil. (2) In a given period, more C was emitted to the atmosphere in the dung combustion situation than that in the dung returned to soil situation. (3) The energy grazing alpine meadow ecosystem changed into a net C source, and the net biome production of the ecosystem dropped to ?15.18 g C/m2 year in the dung combustion situation, 42.95 g C/m2 year less than that in the dung returned situation. To reduce the CO2 emission derived from dung use, the proportion of dung combustion should be reduced and alternative renewable energy such as solar, wind, or hydro energy should be advocated, which is suitable for, and accessible to, the north Tibetan plateau.  相似文献   

11.
In the present study, bioelectricity generation using a living plant in soil was achieved by converting solar energy into electricity on the principles of plant photosynthesis. The plants Chlorophytum comosum, Chasmanthe floribunda and Papyrus diffuses were used in microbial fuel cells (MFCs) and produced, respectively, a maximum current of 25, 31 and 19 mA/m2, without the use of any nutrient or membrane. In this study, the importance of light was demonstrated by the high current values generated during daytime, and the microorganisms at the anode-rhizosphere interface were examined.  相似文献   

12.
Abstract

The modification effect of Nafion on the generation performance at different temperatures and methanol concentrations was investigated. The direct methanol fuel cell performances and electrochemical properties of the DMFC system using as-received Nafion117, a modified Nafion membrane, and using the Nafion117 MEA preparation by spray treatment on the surface of each catalyst layer for conductivity improvement. The open circuit voltage using the modified Nafion membrane was higher than that using Nafion117 at the cell temperature of 343–383 K and methanol concentration of 1.5–10 kmol/m3. The spray treatment of MEA was effective and improved the short circuit current up to 461 mA/cm2 at a 5 kmol/m3 methanol concentration in comparison with no treatment of MEA because of the low interfacial resistance. The power density of 75 mW/cm2 (no treatment Nafion117 MEA:40 mW/cm2) was obtained. The method of the spray treatment was found to be very effective for the DMFC system. The cell performance of Nafion117 MEA increased with the methanol concentration because of the reduction of the concentration overvoltage.  相似文献   

13.
Variation in drying material and their biological differences, coupled with heat supply method in different dryers, makes mathematical modeling of drying complicated. Attempt was made to simulate a drying process and to identify best suitable model out of six selected drying models, for drying of ginger slices in a solar-biomass integrated drying system designed and developed for spice drying. Moisture content data were converted into the moisture ratio (MR) expressions and curve fitting with drying time for the selected drying models was analyzed. Sigma Plot software was used for nonlinear regression to the data obtained during drying and for modeling of drying curves. The suitability of the models was evaluated in terms of statistical parameters such as coefficient of determination (R2), mean percentage error (P), and standard error estimate. Drying air temperature was in the range of 47–55°C and air velocity was between 1.0 and 1.3 m s?1. Ginger slices were dried from 88.13% to 7.65 ± 0.65% (wb) in 16 h. Trays were interchanged in a predetermined matrix sequence from 4 h onwards when moisture content was reduced to 60–70% (wb), for uniformity in drying. Highest value of R2 (0.997), lowest value of SEE (0.020), and P value < 0.0001 established Page model as the best suitable model for the developed drying system. The predicted MRs were in good agreement with the experimental values and the effective moisture diffusivity for ginger was found to be 2.97 × 10–7 m2 s?1.  相似文献   

14.
The heat-pipe solar water heating (HP-SWH) system and the heat-pipe photovoltaic/thermal (HP-PV/T) system are two practical solar systems, both of which use heat pipes to transfer heat. By selecting appropriate working fluid of the heat-pipes, these systems can be used in the cold region without being frozen. However, performances of these two solar systems are different because the HP-PV/T system can simultaneously provide electricity and heat, whereas the HP-SWH system provides heat only. In order to understand these two systems, this work presents a mathematical model for each system to study their one-day and annual performances. One-day simulation results showed that the HP-SWH system obtained more thermal energy and total energy than the HP-PV/T system while the HP-PV/T system achieved higher exergy efficiency than the HP-SWH system. Annual simulation results indicated that the HP-SWH system can heat the water to the available temperature (45°C) solely by solar energy for more than 121 days per year in typical climate regions of China, Hong Kong, Lhasa, and Beijing, while the HP-PV/T system can only work for not more than 102 days. The HP-PV/T system, however, can provide an additional electricity output of 73.019 kWh/m2, 129.472 kWh/m2, and 90.309 kWh/m2 per unit collector area in the three regions, respectively.  相似文献   

15.
The Opuha Dam was designed for water storage, hydropower, and to augment summer low flows. Following its commissioning in 1999, algal blooms (dominated first by Phormidium and later Didymosphenia geminata) downstream of the dam were attributed to the reduced frequency and magnitude of high-flow events. In this study, we used a 20-year monitoring dataset to quantify changes associated with the dam. We also studied the effectiveness of flushing flows to remove periphyton from the river bed. Following the completion of the dam, daily maximum flows downstream have exceeded 100 m3 s?1 only three times; two of these floods exceeded the pre-dam mean annual flood of 203 m3 s?1 (compared to 19 times >100 m3 s?1 and 6 times >203 m3 s?1 in the 8 years of record before the dam). Other changes downstream included increases in water temperature, bed armoring, frequency of algal blooms, and changes to the aquatic invertebrate community. Seven experimental flushing flows resulted in limited periphyton reductions. Flood wave attenuation, bed armoring, and a shortage of surface sand and gravel, likely limited the effectiveness of these moderate floods. Floods similar to pre-dam levels may be effective for control of periphyton downstream; however, flushing flows of that magnitude are not possible with the existing dam infrastructure. These results highlight the need for dams to be planned and built with the capacity to provide the natural range of flows for adaptive management, particularly high flows.  相似文献   

16.
Wildlife incidents with aircraft cost the United States (U.S.) civil aviation industry >US$1.4 billion in estimated damages and loss of revenue from 1990 to 2009. Although terrestrial mammals represented only 2.3 % of wildlife incidents, damage to aircraft occurred in 59 % of mammal incidents. We examined mammal incidents (excluding bats) at all airports in the Federal Aviation Administration (FAA) National Wildlife Strike Database from 1990 to 2010 to characterize these incidents by airport type: Part-139 certified (certificated) and general aviation (GA). We also calculated relative hazard scores for species most frequently involved in incidents. We found certificated airports had more than twice as many incidents as GA airports. Incidents were most frequent in October (n = 215 of 1,764 total) at certificated airports and November (n = 111 of 741 total) at GA airports. Most (63.2 %) incidents at all airports (n = 1,523) occurred at night but the greatest incident rate occurred at dusk (177.3 incidents/hr). More incidents with damage (n = 1,594) occurred at GA airports (38.6 %) than certificated airports (19.0 %). Artiodactyla (even-toed ungulates) incidents incurred greatest (92.4 %) damage costs (n = 326; US$51.8 million) overall and mule deer (Odocoileus hemionus) was the most hazardous species. Overall, relative hazard score increased with increasing log body mass. Frequency of incidents was influenced by species relative seasonal abundance and behavior. We recommend airport wildlife officials evaluate the risks mammal species pose to aircraft based on the hazard information we provide and consider prioritizing management strategies that emphasize reducing their occurrence on airport property.  相似文献   

17.
A novel design of twin-chamber community solar (TCCS) cooker is presented as a replacement of biomass-based cooking. The novelty of separating a single rectangular cooking chamber into separate twin chambers (of 1-m2 aperture area each) improves the cooking performance as opening of one chamber for unloading of food cooked in lesser time (rice) does not disturb the stagnation temperature of the other chamber (pulses and meat) needing more time to cook besides resulting in reduction in side heat loss coefficient due to common wall. Aperture area and cooking volume of TCCS cooker are 9.54 and 35.33 times more as compared to single-chamber domestic solar (SCDS) cooker which makes it a community-scale large-capacity solar cooker. The developed solar radiation capture model and overall heat loss coefficient (Ul) computed for TCCS cooker have been used in a thermal model developed between various interactive components. First (F1) and second figures of merit (F2) values are 0.13 and 0.42, respectively, for TCCS cooker at par with ‘A’ grade category SCDS cooker. Techno-economic analysis shows that the net present value of TCCS cooker is Rs. 83,253 with break-even point occurring after cooking 43,461 meals with payback period of only 25, 50, and 72 months if used as a replacement for LPG, cow dung cakes, and wood-based cooking, respectively. Environmental impact analysis shows that the use of the proposed cooker can mitigate 2, 5.9, and 4.1 tonnes of CO2 emissions every year by not burning LPG, cow dung cakes, and wood respectively.  相似文献   

18.
Prescribed fire is a common site preparation practice in forest management in southern China. However, the effect of fire on soil properties and N transformations is still poorly understood in this region. In this study, soil properties and N transformations in burned and unburned site of two vegetation types (Eucalyptus plantation and shrubland) were compared in rainy and dry seasons after 2 years’ prescribed fire. Soil pH and soil NH4-N were all higher in the burned site compared to the unburned control. Furthermore, burned sites had 30–40 % lower of soil total phosphorus than conspecific unburned sites. There was no difference in soil organic matter, total N, soil exchangeable cations, available P or NO3-N. Nitrogen mineralization rate of 0–5 cm soil in the unburned site ranged from 8.24 to 11.6 mg N kg?1 soil month?1 in the rainy season, compared to a lower level of 4.82–5.25 mg N kg?1 soil month?1 in the burned sites. In contrast, 0–5 cm layer nitrification rate was overall 2.47 mg N kg?1 soil month?1 in the rainy season, and was not significantly affected by burning. The reduced understory vegetation coverage after burning may be responsible for the higher soil NH4-N in the burned site. This study highlights that a better understanding the effect of prescribed burning on soil nutrients cycling would provide a critical foundation for management decision and be beneficial to afforestation in southern China.  相似文献   

19.
Soil analyses were conducted on home lawns across diverse ecoregions of the U.S. to determine the soil organic carbon (SOC) sink capacity of turfgrass soils. Establishment of lawns sequestered SOC over time. Due to variations in ecoregions, sequestration rates varied among sites from 0.9 Mg carbon (C) ha?1 year?1 to 5.4 Mg C ha?1 year?1. Potential SOC sink capacity also varied among sites ranging from 20.8 ± 1.0–96.3 ± 6.0 Mg C ha?1. Average sequestration rate and sink capacity for all sites sampled were 2.8 ± 0.3 Mg C ha?1 year?1 and 45.8 ± 3.5 Mg C ha?1, respectively. Additionally, the hidden carbon costs (HCC) due to lawn mowing (189.7 kg Ce (carbon equivalent) ha?1 year?1) and fertilizer use (63.6 kg Ce ha?1 year?1) for all sites totaled 254.3 kg Ce ha?1 year?1. Considering home lawn SOC sink capacity and HCC, mean home lawn sequestration was completely negated 184 years post establishment. The potential SOC sink capacity of home lawns in the U.S. was estimated at 496.3 Tg C, with HCC of between 2,504.1 Gg Ce year?1 under low management regimes and 7551.4 Gg Ce year?1 under high management. This leads to a carbon-positive system for between 66 and 199 years in U.S. home lawns. More efficient and reduction of C-intensive maintenance practices could increase the overall sequestration longevity of home lawns and improve their climate change mitigation potential.  相似文献   

20.
Rainwater conservation and recycling by optimal size on-farm reservoir   总被引:4,自引:0,他引:4  
Hydrologic and economic analysis of the on-farm reservoir (OFR) was carried out in rainfed rice–mustard cropping systems in Eastern India followed by 2 years of field experiments in 1999 and 2000. The average contribution (average of 2 years) of direct rainfall and surface runoff from the diked crop fields contributed, respectively, about 79.5 and 20.5% to the total OFR inflow. The average contribution of evaporation loss, seepage and percolation loss and supplemental irrigation from the OFR contributed, respectively, about 10.0, 31.2 and 58.8% to the total OFR outflow. There was an average increase of rice yield of 44.0% over the rainfed rice because of application of 8.4 cm supplemental irrigation from the OFR. Thus, with an application of 4.5 cm supplemental irrigation from the OFR, 15.40% increase of mustard yield was recorded in 1999. Economic analysis indicated average net profit of Rs. 700 (US$ 1 = Rupees (Rs.) 44.75 in Indian currency) from a farm area of 800 m2. Average values of benefit–cost ratio, internal rate of return and pay back period of the OFR irrigation system were evaluated as 1.17, 14.8%, and 16 years, respectively. The study reveals that the OFR irrigation in small landholders is economically feasible system for rainwater harvesting and providing supplemental irrigation in rainfed farming system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号