首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
Different passive sampler housings were evaluated for their wind dampening ability and how this might translate to variability in sampler uptake rates. Polyurethane foam (PUF) disk samplers were used as the sampling medium and were exposed to a PCB-contaminated atmosphere in a wind tunnel. The effect of outside wind speed on PUF disk sampling rates was evaluated by exposing polyurethane foam (PUF) disks to a PCB-contaminated air stream in a wind tunnel over air velocities in the range 0 to 1.75 m s-1. PUF disk sampling rates increased gradually over the range 0-0.9 m s-1 at approximately 4.5-14.6 m3 d-1 and then increased sharply to approximately 42 m3 d-1 at approximately 1.75 m s-1 (sum of PCBs). The results indicate that for most field deployments the conventional 'flying saucer' housing adequately dampens the wind effect and will yield approximately time-weighted air concentrations.  相似文献   

2.
3.
Passive samplers with polyurethane disks (PUF) were applied in the determination of the concentration of polycyclic aromatic hydrocarbons (PAHs) in ambient air in six residential areas in the Philippines during four simultaneous sampling periods. The uptake profiles of PAHs were determined at one site during one sampling period. Most of the PAHs that were detected in air at concentrations that were significantly higher than their analytical detection limits exhibited a linear uptake trend on the PUF disk. The linear uptake profiles of some high molecular weight (HMW) PAHs were not established and this is attributed to the low concentration of the compounds in air in the gaseous phase. The retention concentrations of phenanthrene-d-10 were determined after depuration in four sampling sites during two sampling periods. The sampling rate for phenanthrene-d-10 was calculated at the linear phase of the uptake using the kA derived from depuration experiments and the relationship of kA and sampling rate which was established in a previous passive sampling study. The average sampling rate obtained for phenanthrene d-10 (2.94±0.69 m3 d−1) was applied for derivation of the concentrations of the PAHs in the field samples.The passive sampler with PUF disk and short integration time of 42–56 days is applicable for the derivation of the concentrations of PAHs in ambient air in the Philippines. The concentrations of the organic pollutants derived from the passive sampler showed variability for the six residential areas; reflecting the influence of possible sources of emission of the pollutants at the sites at the different sampling periods. The weather conditions, including the occurrence of a tropical cyclone, increased rainfall and high-relative humidity during the rainy season, had an influence on the concentrations of PAHs derived by the passive sampler.  相似文献   

4.
At locations without access to the electrical grid, a flow-through sampler (FTS) collects large volumes of air for the analysis of semi-volatile organic compounds (SVOCs). To test its performance under field conditions, an FTS and a traditional pumped high volume air sampler, both using polyurethane foam (PUF) as sampling medium, were co-deployed at the campus of the University of Toronto Scarborough from August 2006 to June 2007. Polybrominated diphenyl ethers (PBDEs) and various pesticides were quantified in the samples taken by both samplers to test the FTS's applicability to relatively non-volatile and slightly polar SVOCs. Air concentrations in samples taken with the FTS over five 2-week periods compare favourably with the average of the concentrations in several 24-h active high volume samples taken during the same period. In particular, time trends, temperature dependence relationships, and isomer ratios show a reasonable agreement between the two sampling techniques. An empirical linear solvation energy relationship for predicting the apparent theoretical plate number of the PUF assembly used in the FTS illustrates the effect of chemical properties, as well as temperature and wind speed, on sampling efficiency. In the absence of electrical power, the FTS can collect SVOCs from large air volumes as reliably and quantitatively as traditional HiVol samplers, although without separating gas and particle phase.  相似文献   

5.
Paschke H  Popp P 《Chemosphere》2005,58(7):855-863
Two new types of passive samplers were designed and tested on semivolatile organic compounds. The first type (a spiral-rod sampler) consists of a low-density polyethylene membrane acting as a permeation film and a silicone elastomer as the receiving material; the second (a stir-bar sampler) has the same membrane material but a polydimethylsiloxane-coated stir bar acting as the collector phase and installed radially symmetrically in the sampler. The advantages of the new samplers are their simple design, low costs, and their easy processing via thermodesorption coupled with capillary gas chromatography and mass selective detection. In both samplers, the uptake of selected analytes was integrative over exposure periods of up to 384 h. The sampling rates calculated from a laboratory calibration study using the chlorinated semivolatiles hexachlorobenzene, hexachlorocyclohexane isomers and polychlorinated biphenyls ranged from 88.1 ml h-1 for delta-hexachlorocyclohexane to 3443 ml h-1 for 2,2',5,5'-tetrachlorobiphenyl. A field trial at a hazardous waste dump near Bitterfeld, Germany, for up to 21 days combined with periodical determinations of air concentrations using low-volume sampling indicated that the new samplers can in principle be used in the field, although the sampling rates derived from the field results differed considerably from the laboratory findings. Nevertheless the preliminary results suggest that the new sampler types are promising for the long-term air monitoring of semivolatiles.  相似文献   

6.
To effectively use a passive sampler for monitoring trace contaminants in the gas-phase, its sampling characteristics as a function of ambient wind conditions must be known. In this study two commonly used passive samplers were evaluated using computational fluid dynamics. Contaminant uptake by the polyurethane foam (PUF) was modeled using a species transport model. The external-internal flow interactions in the sampler were characterized, and the uptake rates of contaminant species were quantified. The simulations show that flow fields in the samplers have strong velocity gradients, and single-point velocity measurements do not capture flow interactions accurately. Sampling rates calculated for a PUF in freestream are in good agreement with sampling rates for PUFs in the passive samplers studied for the same average velocity over the PUF. The calculated sampling rates are in general agreement with those obtained experimentally by other researchers.  相似文献   

7.
The concentrations of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) were determined in air samples collected at four sampling sites located in two zones of Barcelona (Spain): near a municipal solid waste incinerator (MSWI) and a combined cycle power plant (3 sites), and at a background/control site. Samples were collected using high-volume active samplers. Moreover, 4 PUF passive samplers were deployed at the same sampling points during three months. For PCDD/Fs, total WHO-TEQ values were 27.3 and 10.9 fg WHO-TEQm(-3) at the urban/industrial and the background sites, respectively. The sum of 7 PCB congeners and the Sigma PCN levels were also higher at the industrial site than at the background site. In order to compare active and passive sampling, the accumulated amounts of PCDD/Fs, PCBs and PCNs in the four passive air samplers, as well as the total toxic equivalents in each sampling site were also determined. To assess the use of PUF passive samplers as a complementary tool for PCDD/F, PCB and PCN monitoring, sampling rates were calculated in accordance with the theory of passive air samplers. PUF disks allowed establishing differences among zones for the POP levels, showing that they can be a suitable method to determine POP concentrations in air in areas with various potential emission sources. Although both particle and gas phase were sorbed by the PUFs, data of gas phase congeners are more reproducible.  相似文献   

8.
Passive air samplers (PAS) can be used to monitor semi-volatile organic compounds in the atmosphere. Polyurethane foam (PUF) disks are a popular sampling medium because they have a high retention capacity for such compounds. This paper reports a highly time-resolved uptake study, to derive uptake rate data under field conditions, and investigate the effects of using different foam densities on the uptake rate. PUF disks were deployed alongside an active sampler, for periods of up to 12 weeks. The uptake rates were measured for a range of gas- and particle-bound persistent organic pollutants (polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs)), of different properties, to explore whether gas–particle partitioning affected uptake rate. Uptake rates for two different densities of foam (0.021 and 0.035 g cm?3) were not statistically significantly different from each other. Uptake rates of light PCBs averaged ~6.5 m3 day?1, somewhat higher than in previous studies; higher wind speeds and lower temperatures in this study are the likely reason for this difference. The study showed: i) the uptake rate of the compound with lowest KOA considered in this study (PCB-28/31) declined in the later weeks, indicating an approach to equilibrium; ii) uptake rates of lighter BDEs and heavier PCBs (compounds of intermediate KOA in this study) remain similar throughout the study period, indicating that they are not approaching equilibrium during the 12-week-study; iii) uptake rates were typically: ~8 m3 day?1 for PCB-52; ~9.5 m3 day?1 for PCB-95; ~11 m3 day?1 for BDE-28 and ~2 m3 day?1 BDE-99. The latter compound has an important particle-bound component and this lowers the sampling rate compared to predicted uptake rates for compounds which are in the gas phase only. It is shown that knowledge of gas–particle partitioning is needed to correct for this effect, and to improve predicted uptake rates.  相似文献   

9.
The focus of this study was to characterize the concentration levels of selected PCBs and compare them to compiled data in order to contribute to the international database. The sampling site is located in the outskirts of Madrid and can be considered an open urban area. 32 samples of air were taken from February 1998 to June 1998 by using a high volume air sampler. Glass fiber filters and polyurethane foam (PUF) were used to collect the paniculate and gas phase material, respectively. PUF plugs were Soxhlet extracted and filters were ultrasonically extracted by using pesticide-grade hexane and dichloromethane, respectively. The cleanup procedure was carried out on a florisil column with hexane and hexane/dichloromethane as elution solvents. GC/MS in a selected ion monitoring mode was used for quantification and 29 selected PCBs congeners were analyzed.  相似文献   

10.
The first survey of persistent organic pollutant (POP) concentrations in air across several Indian agricultural regions was conducted in 2006-2007. Passive samplers comprising polyurethane foam (PUF) disks were deployed on a quarterly basis at seven stations in agricultural regions, one urban site and one background site. The project was conducted as a sub-project of the Global Atmospheric Passive Sampling (GAPS) Network. In addition to revealing new information on air concentrations of several organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs), the study has demonstrated the feasibility of conducting regional-scale monitoring for POPs in India using PUF disk samplers. The following analytes were detected with relatively high concentrations in air (mean for 2006 and 2007, pg/m3): α- and γ-hexachlorocyclohexane (HCH) (292 and 812, respectively); endosulfan I and II (2770 and 902, respectively); p,p′-DDE and p,p′-DDT (247 and 931, respectively); and for the sum of 48 PCBs, 12,100 (including a site with extremely high air concentrations in 2007) and 972 (when excluding data for this site).  相似文献   

11.
Polar organic chemical integrative samplers (POCIS) are useful for monitoring a wide range of chemicals, including polar pesticides, in water bodies. However, few calibration data are available, which limits the use of these samplers for time-weighted average concentration measurements in an aquatic medium. This work deals with the laboratory calibration of the pharmaceutical configuration of a polar organic chemical integrative sampler (pharm-POCIS) for calculating the sampling rates of 17 polar pesticides (1.15?≤?logK ow?≤?3.71) commonly found in water. The experiment, conducted for 21 days in a continuous water flow-through exposure system, showed an integrative accumulation of all studied pesticides for 15 days. Three compounds (metalaxyl, azoxystrobine, and terbuthylazine) remained integrative for the 21-day experiment. The sampling rates measured ranged from 67.9 to 279 mL?day?1 and increased with the hydrophobicity of the pesticides until reaching a plateau where no significant variation in sampling rate is observed when increasing the hydrophobicity.  相似文献   

12.
Harman C  Tollefsen KE  Bøyum O  Thomas K  Grung M 《Chemosphere》2008,72(10):1510-1516
Passive sampling devices provide a useful contribution to the monitoring of contaminants in the aquatic environment. However, calibration data needed for the calculation of water concentrations from sampler accumulations are restricted to a limited number of compound classes. Thus uptake of a range of alkylated phenols (AP), polycyclic aromatic hydrocarbons (PAH) and carbazoles was determined for semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS) using a flow through exposure system. Sampling rates ranged from 0.02 to 0.26 l d(-1) for POCIS and 0.02 to 13.83 l d(-1) for SPMDs. Observed SPMD uptake was also compared to that predicted by an empirical model including the use of performance reference compounds (PRCs). Predicted sampling rates did not differ by more than a factor of 1.3 from experimental values for PAH, providing further evidence that the PRC approach can be successfully used to determine in situ sampling rates for these compounds. Experimental sampling rates for AP in SPMDs were, however, much lower than predicted. This discrepancy was too large to be explained by small uncertainties in the calibration system or in the calculations. Based on these data we conclude that while hydrophobic AP are accumulated by SPMDs their partitioning cannot be predicted from their logK(ow) using current methods. Due to this lower than expected uptake, sampling rates were only higher in SPMDs than POCIS in the range of logK(ow)>5.0. Simultaneous deployment of both sampler types allows the study of compounds with a broad range of physicochemical properties.  相似文献   

13.
Passive air samplers consisting of polyurethane foam (PUF) disks housed in chambers were deployed at several sites along a approximately 75 km urban-rural gradient in Toronto and analyzed for polybrominated diphenyl ethers (PBDEs). Samplers were allowed to integrate gas-phase PBDEs over three consecutive seasons starting in the summer of 2000. PBDEs were fairly uniform along the transect with air concentrations in Toronto (10-30 pgm(-3)) about a factor of two greater than at rural sites. Lowest concentrations were observed during the winter and probably associated with reduced inputs from indoor sources of PBDEs and to a preference for PBDEs to partition to the particle-phase at colder temperatures. The composition of PBDEs in the air samples did not differ across the transect or for the different seasons.  相似文献   

14.
Wang Y  Wang P  Fu J  Jiang G 《Chemosphere》2012,86(3):217-222
The effluents and sludge from municipal sewage treatment plants (MSTPs) are considered as potential sources of many contaminants to the ambient environments. In the present work, the air-water exchange of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) was studied using passive air samplers at an urban lake, which receives the effluents from a MSTP in Beijing, China. The concentrations of PCBs and PBDEs in atmosphere were in the range 15.5-108 ng sample−1 and 2.37-27.8 ng sample−1, respectively, during the sampling period (August, 2007-July, 2008). The predominant PCBs and PBDEs were lowly halogenated congeners. The calculation for the exchange fluxes of PCBs and PBDEs using fugacity model showed that, the net exchange fluxes in different seasons were closely related to the halogen number of different congeners. Except for CBs-28 and 52, the net exchange fluxes was mainly directed from air to water for most of predominant congeners, which implied that the lower chlorinated CBs were dominated by volatilization process rather than the dry/wet depositions and diffusion between air-water interface, additionally, for heavy congeners, the dry/wet deposition process was an important source of PCBs and PBDEs in this lake.  相似文献   

15.
The Palmes' tube, the first diffusive sampler incorporating a fixed path length, has received wide usage for the sampling of a large number of gaseous pollutants. But despite numerous previous studies, questions remain regarding the accuracy of these inexpensive, simple-to-construct, open-ended samplers. Here the mass transfer resistance in a Palmes' diffusive sampler was measured using the loss of cyclohexane from a Palmes' tube containing liquid cyclohexane at its base. The average loss rates, at factorial combinations of five air incidence angles evenly spaced from 270 degrees to 90 degrees, and five air speeds from 0.5 m/sec to 2.5 m/sec ranged from 46% to 121% higher than rates calculated from the physical dimensions of the sampler, proving the need to calibrate these samplers rather than relying on a theoretical calculation. The mass transfer resistance was nearly constant when the airflow was perpendicular to the sampler and sufficiently high to avoid stagnation, a finding that may explain the widespread acceptance of the results obtained using this sampler.  相似文献   

16.
Performance reference compound (PRC) derived sampling rates were determined for polyurethane foam (PUF) passive air samplers in both sub-tropical and temperate locations across Australia. These estimates were on average a factor of 2.7 times higher in summer than winter. The known effects of wind speed and temperature on mass transfer coefficients could not account for this observation. Sampling rates are often derived using ambient temperatures, not the actual temperatures within deployment chambers. If deployment chamber temperatures are in fact higher than ambient temperatures, estimated sampler-air partition coefficients would be greater than actual partition coefficients resulting in an overestimation of PRC derived sampling rates. Sampling rates determined under measured ambient temperatures and estimated deployment chamber temperatures in summer ranged from 7.1 to 10 m3 day−1 and 2.2-6.8 m3 day−1 respectively. These results suggest that potential differences between ambient and deployment chamber temperatures should be considered when deriving PRC-based sampling rates.  相似文献   

17.
O'Brien D  Bartkow M  Mueller JF 《Chemosphere》2011,83(9):1290-1295
The use of the adsorbent styrenedivinylbenzene-reverse phase sulfonated (SDB-RPD) Empore disk in a chemcatcher type passive sampler is routinely applied in Australia when monitoring herbicides in aquatic environments. One key challenge in the use of passive samplers is mitigating the potentially confounding effects of varying flow conditions on chemical uptake by the passive sampler. Performance reference compounds (PRCs) may be applied to correct sampling rates (Rs) for site specific changed in flow and temperature however evidence suggests the use of PRCs is unreliable when applied to adsorbent passive samplers. The use of the passive flow monitor (PFM) has been introduced for the assessment of site-specific changes in water flow. In the presented study we have demonstrated that the Rs at which both atrazine and prometryn are accumulated within the SDB-RPD-Empore disk is dependent on the flow conditions. Further, the calibration of the measured Rs for chemical uptake by the SDB-RPD-Empore disk to the mass lost from the PFM has shown that the PFM provides an accurate measure of Rs for flow velocities from 0 to 16 cm s−1. Notably, for flow rates >16 cm s−1, a non linear increase in the Rs of both herbicides was observed which indicates that the key resistance to uptake into the SDB-RPD Empore disk is associated with the diffusion through the overlying diffusion limiting membrane. Overall the greatest uncertainty remains at very low flow conditions, which are unlikely to often occur in surface waters. Validation of the PFM use has also been undertaken in a limited field study.  相似文献   

18.
The different barks were sampled to discuss the influence of the tree species, trunk circumference, and bark thickness on the accumulation processes of polybrominated diphenyl ethers (PBDEs) from air into the bark. The results of different PBDE concentrations indicated that barks with a thickness of 0–3 mm collected from weeping willow, Camphor tree, and Masson pine, the trunk circumferences of which were 100 to 150 cm, were better PBDEs passive samplers. Furthermore, tree bark and the corresponding air samples were collected at Anji (AJ), Hangzhou (HZ), Shanghai (SH), and Wenling (WL) to investigate the relationship between the PBDE concentrations in bark and those in air. In addition, the significant correlation (r 2?=?0.906; P?<?0.05) indicated that atmospheric PBDEs were the principle source for the accumulation of PBDEs in the barks. In this study, the log K BA (bark–air partition coefficient) of individual PBDE congeners at the four sites were in the range from 5.69 to 6.79. Finally, the total PBDE concentration in WL was 5 to 20 times higher than in the other three cities. The result indicated that crude household workshops contributed a heavy amount of PBDEs pollution to the environment, which had been verified by the spatial distribution of PBDEs levels in barks collected at Wenling (range, 26.53–1317.68 ng/g dw). The good correlation between the PBDE concentrations in the barks and the air samples and the variations of the PBDE concentrations in tree barks collected from different sites reflected that the bark could be used as a passive sampler to indicate the atmospheric PBDEs.  相似文献   

19.
Passive sampling is a powerful method for continuous pollution monitoring, but calibration experiments are still needed to generate sampling rates in order to estimate water concentrations for polar compounds. We calibrated the Chemcatcher device with an uncovered SDB-XC Empore disk as receiving phase for 12 polar and semi-polar pesticides in aquatic environments in flow-through tank experiments at two water flow velocities (0.135 m/s and 0.4 m/s). In the 14-day period of exposure the uptake of test substances in the sampler remained linear, and all derived sampling rates R(s) were in the range of 0.1 to 0.5 L/day. By additionally monitoring the release of two preloaded polar pesticides from the SDB-XC disks over time, very high variation in release kinetics was found, which calls into question the applicability of performance reference compounds. Our study expands the applicability of the Chemcatcher for monitoring trace concentrations of pesticides with frequent occurrence in water.  相似文献   

20.
Hogarh JN  Seike N  Kobara Y  Habib A  Nam JJ  Lee JS  Li Q  Liu X  Li J  Zhang G  Masunaga S 《Chemosphere》2012,86(7):718-726
A comprehensive congener specific evaluation of polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) in the atmosphere was conducted across East Asia in spring 2008, applying polyurethane foam (PUF) disk passive air sampler (PAS) as monitoring device. Mean concentrations derived for Japan, China and Korea were 184 ± 24, 1100 ± 118, and 156 ± 20 pg m−3 for ∑202 PCBs, and 9.5 ± 1.5, 61 ± 6, and 16 ± 2.4 pg m−3 for ∑63 PCNs, respectively. Relative to reported data from 2004, the present results suggest that air PCBs concentrations have not changed much in Japan and Korea, while it has increased by one order of magnitude in China. From principal component analysis, combustion emerged highly culpable in contemporary emissions of both PCBs and PCNs across the East Asian sub-region. Another factor derived as important to air PCBs was re-emissions/volatilization. Signals from PCBs formulations were also picked, but their general importance was virtually consigned to the re-emissions/volatilization tendencies. On the contrary, counterpart PCNs formulations did not appear to contribute much to air PCNs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号