首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Recent research has indicated that insoluble ultrafine aerosols (ie., particles whose physical diameters are less than 100 nm) may cause adverse health effects due to their small size, and that toxicological response may be more appropriately represented by particle number or particle surface area. Unfortunately, current exposure criteria and the associated air-sampling techniques are primarily mass-based. Welding processes are high-temperature operations that generate substantial number concentrations of ultrafine aerosols. Welding aerosols are formed primarily through the nucleation of metal vapors followed by competing growth mechanisms such as coagulation and condensation. Experimental results and mathematical tools are presented to illustrate how welding metallurgy influences the chemical aspects and dynamic processes that initiate and evolve the resultant aerosol. This research suggests that a fundamental understanding of metallurgy and aerosol physics can be exploited to suppress the formation of undesirable chemical species as well as the amount of aerosol generated during a welding process.  相似文献   

2.
Ambient aerosol concentrations along the roadside of metropolitan cities of Pakistan were measured using a Grimm 1.109 dust monitor. Considering the high ambient aerosol concentrations, regional lung deposition of aerosol particles in the human respiratory tract was calculated to assess extent of exposure. Lung deposition was computed in terms of mass concentration and the associated surface area for 12 male traffic wardens using the latest version of the stochastic lung deposition code Inhalation, Deposition, and Exhalation of Aerosols in the Lung. The results have revealed 4 to 10 times higher concentrations than recommended by WHO guidelines. The deposition results derived from the model disclose that extrathoracic deposition is in the range of 22 to 28 % with total lung deposition ranging from 40 to 44 % for the scanned particle window of 0.25–10 μm. Considering an average 8-h shift per day and an average breathing rate of 1.3 m3?h?1, it is approximated that in a worker, up to 1.6 mg of inhalable particle mass can deposit per day.  相似文献   

3.
The Respicon has been introduced as a sampler for health related measurements of airborne contaminants at workplaces. The instrument is aimed at simultaneous collection of three health related aerosol fractions: (a) the coarser inhalable fraction, defining the aerosol fraction that may enter the nose and mouth during breathing; (b) the intermediate thoracic fraction, defining the fraction that may penetrate beyond the larynx and so reach the lung; and (c) the finer respirable fraction, defining the fraction that may penetrate to gas exchange region of the lung. The instrument has a number of features attractive to occupational hygienists: in addition to providing the three aerosol fractions simultaneously, it is light and compact enough to be used as a personal sampler. yet can be a tripod mounted for area sampling, it can provide samples not only for gravimetric analysis but also microscopic and chemical analyses; and it is also available in a photometric direct-reading version. The instrument has previously been evaluated as an area sampler and, in this mode of operation, has shown reasonable accuracy in collecting respirable, thoracic and inhalable particles, the latter up to particle diameters of ca. 80 microm. Except for some scattered unpublished data there exist no systematic investigations in the Respicon's performance when used as a personal sampler in the industrial environment. In this paper, we will report on a study of side by side comparison of the Respicon with the IOM inhalable sampler, regarded as a reference instrument for the inhalable fraction. The main study was performed at six different workplaces in a nickel refinery. Statistical analysis of the gravimetrically-determined concentration data reveals consistently lower aerosol exposure values for the Respicon as compared to the IOM sampler. The data for the nickel workplaces are compared with findings from other studies. The results are interpreted in the light of the overall results and the possibility of introducing a correction factor is discussed.  相似文献   

4.
Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM? 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO?) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions calculated from the OPC data are closely correlated with the results of the particle size-selective sampling using the CIP 10. Furthermore, the OPC data allow calculation of the thoracic fraction of workplace aerosol (not measured by sampling), which is interesting in the presence of allergenic particles like fungi spores. The results also show that the modified COP inlet adequately samples inhalable aerosol in the range of workplace particle-size distribution.  相似文献   

5.
Standardized conventions governing the fractions of airborne particles that can penetrate the human head airways, the thoracic airways and the alveolar spaces have been internationally (although not universally) adopted. Several agencies involved in setting limit values for occupational exposure concentrations have taken these conventions into account when considering the appropriate standard for specific chemicals, in order to ensure the standards are biologically relevant. A convention is selected based on the characteristic health effects, and forms the basis of measurement against the limiting concentration value. In order to assess exposure for comparison to this metric or any other purposes, it is necessary to choose a sampler whose performance matches the convention, and protocols have been developed and used to test sampler performance. Several aerosol sampling devices are available, nominally at least, for each of the conventions. Some considerations important to the sampling of airborne particles containing beryllium with regard to the sampling conventions, the test protocols and sampler performance are discussed.  相似文献   

6.
In 2002 the Comité Européen Normalisation (CEN) published its document Workplace atmospheres-assessment of performance of instruments for measurement of airborne particle concentrations (EN 13205) that describes a standard protocol by which to carry out the testing and validation of personal aerosol samplers of the type widely used for occupational aerosol exposure assessment. It emerged from more than a decade of discussion and a large body of research experience involving several laboratories. The protocol that is described, however, still poses significant technical and economic challenges, not least because it involves laborious-and hence costly-procedures in large, specialized wind tunnel facilities. More recent research has identified a number of areas by which the protocol may be improved and made more accessible to testing laboratories, including a set of validated aerosol sampler scaling laws, a better understanding of the reduced role of the bluff body of the wearer on sampler performance, and the availability of new options for rapid sampler testing methods. Taking these into account, a dummy new protocol is offered for discussion.  相似文献   

7.
Little is known about the physicochemical properties of beryllium aerosols associated with increased risk of beryllium sensitization and chronic beryllium disease (CBD). Such information is needed to evaluate whether airborne mass of beryllium is the appropriate metric of exposure or alternatively to provide a scientific basis for using information on particle size, surface area, and chemistry to support an improved exposure limit based on bioavailability through the inhalation and dermal routes of exposure. Thus, we used a suite of analytical techniques to characterize aerodynamically size-fractionated beryllium particles and powders that have been associated in epidemiological studies with higher prevalence of CBD. Aerosol particles were sampled from the ventilation systems of production lines for powders of beryllium metal and beryllium oxide and for ingots of copper-beryllium alloy. End product powders from the metal and oxide production lines were also collected.Particles released during production of beryllium metal were found to be complex, having heterogeneous composition, including reactive species such as fluorine. Powders from beryllium metal production were of high purity with only a minor component of beryllium oxide. Both particles and powders from oxide production were high-purity oxide. Particles released during production of copper-beryllium alloy were heterogeneous, being predominantly copper oxides. Thus, all particles and powders contain at least some beryllium in the form of beryllium oxide.These data justify efforts to thoroughly characterize beryllium aerosol properties when performing exposure assessments. The data also suggest that differences in particle chemical composition, size, number, and surface area may influence bioavailability of beryllium and contribute to risk of CBD. However, a scientific basis does not yet exist to replace mass as the current metric of exposure.  相似文献   

8.
About 60,000 particles in 288 aerosol samples collected during farm work have been characterised with automated particle analysis using scanning electron microscopy (SEM) and energy dispersive X-ray spectrometry (EDS). Based on EDS-analysis of materials with known composition (potato flour, alpha-quartz, K-feldspar and beta-wollastonite), criteria were developed for classification of particles as: (1) organic, (2) silicon-rich (silica), and (3) other inorganic particles. The reproducibility of the relative mass proportions in dust samples collected during farm work was 0.078 when approximately 200 particles were characterised per sample. Field samples from the farm environment showed clear differences in composition. Generally, inorganic particles dominated the particle mass. The proportion of the organic particle mass was highest for tending of swine and poultry, 55 and 38% respectively. Silica particles amounted to 10 to 20% of the total mass during handling crops, e.g. grain, straw, hay, potatoes, and onions. It seems likely that the results can be used in etiologic studies, but further validation would be needed for quantitative purposes.  相似文献   

9.
The use of hydrated magnesium carbonate hydroxide (magnesia alba) for drying the hands is a strong source for particulate matter in indoor climbing halls. Particle mass concentrations (PM10, PM2.5 and PM1) were measured with an optical particle counter in 9 indoor climbing halls and in 5 sports halls. Mean values for PM10 in indoor climbing halls are generally on the order of 200-500 microg m(-3). For periods of high activity, which last for several hours, PM10 values between 1000 and 4000 microg m(-3) were observed. PM(2.5) is on the order of 30-100 microg m(-3) and reaches values up to 500 microg m(-3), if many users are present. In sports halls, the mass concentrations are usually much lower (PM10 < 100 microg m(-3), PM2.5 < or = 20 microg m(-3)). However, for apparatus gymnastics (a sport in which magnesia alba is also used) similar dust concentrations as for indoor climbing were observed. The size distribution and the total particle number concentration (3.7 nm-10 microm electrical mobility diameter) were determined in one climbing hall by an electrical aerosol spectrometer. The highest number concentrations were between 8000 and 12 000 cm(-3), indicating that the use of magnesia alba is no strong source for ultrafine particles. Scanning electron microscopy and energy-dispersive X-ray microanalysis revealed that virtually all particles are hydrated magnesium carbonate hydroxide. In-situ experiments in an environmental scanning electron microscope showed that the particles do not dissolve at relative humidities up to 100%. Thus, it is concluded that solid particles of magnesia alba are airborne and have the potential to deposit in the human respiratory tract. The particle mass concentrations in indoor climbing halls are much higher than those reported for schools and reach, in many cases, levels which are observed for industrial occupations. The observed dust concentrations are below the current occupational exposure limits in Germany of 3 and 10 mg m(-3) for respirable and inhalable dust. However, the dust concentrations exceed the German guide lines for work places without use of hazardous substances. In addition, minimizing dust concentrations to technologically feasible values is required by the current German legislation. Therefore, substantial reduction of the dust concentration is required.  相似文献   

10.
In the frame of assessing exposure to nanostructured particles, the aim of this work is to study the performance of a new device devoted to the real-time measurement of nanostructured aerosol: the meDiSC (Diffusion Size Classifier, Matter Engineering, Switzerland). This instrument is based on unipolar diffusion charging of particles which are then collected successively in diffusion and filtration stages. From currents measured in these stages, the instrument is capable of determining aerosol mean size and number concentration. These data were compared to reference measurements regarding monodisperse aerosols in a range from 20 to 700 nm; the relative biases were found unsatisfying. This led us to investigate the principle of the instrument. Consequently, the charging law of the diffusion charger was experimentally established, as well as the calibration curve allowing the determination of the mean size of the particles. The latter analysis was completed by a model based on diffusion theory. Our results indicate the possibility to improve the range of size measurement up to 350 nm. Measured particle size and number concentration were also used to calculate geometric surface-area concentration; the experimental data were compared to a reference calculated surface-area concentration. The results demonstrate the possibility to evaluate this parameter within acceptable uncertainty. In a second step, the meDiSC was challenged with polydisperse aerosols. It was observed that meDiSC overestimates particle size by a factor 1.7, while particle number concentrations are found within ±40% of the reference. The model applied to polydisperse aerosols indicates that polydispersity little influences particle size up to 300 nm while geometric standard deviation remains below 1.7.  相似文献   

11.
Occupational exposure is the condition of being subjected through employment to a chemical, physical, or biological agent, or to a specific process, practice, behavior, or organization of work. Exposure to a chemical agent is typically the contact of that agent with the outer boundary of a subject, such as the respiratory system, skin, or digestive system. In occupational hygiene we are most concerned with exposure through the respiratory system, although, increasingly we are concerned with the results of dermal exposures, including those exposures to the skin that can be transferred to the mouth and digestive system. This presentation will detail methods available for assessing personal exposures to chemicals through monitoring. The results from monitoring can then be compared to established guidelines and regulations, although this is not the only rationale for making measurements. These monitoring methods are currently used around the world to establish the benchmark hazard from which risk to the worker can be predicted. The presentation will describe the general techniques for assessing exposures to the respiratory system from chemical gases and vapors, chemical dusts, and exposures to the skin from bulk chemicals or chemical contamination of surfaces. For respiratory exposures, direct-reading instruments are available for spot measurements, and for monitoring short-term fluctuations in concentration. However, most standards and regulations are based on time-integrated (time-weighted average) exposures, requiring longer-term integrative methods. Therefore, the specific focus of this review will be the methods available for full work-shift sampling. For gases and vapors this will include taking whole-air samples in canisters or polymer bags, or concentration of chemicals by absorption in liquids or adsorption on solid sorbents, with subsequent chemical analysis. Chemical concentration can take place by pumping air through the sorbing media, or by allowing molecules to diffuse to the sorbent surface. Transfer of the collected chemicals to the analytical instrumentation can be accomplished using solvent displacement and injection, or through the application of heat to bring the collected molecules back into the vapor phase. For particles, the particle size is important as this determines the site of deposition in the lungs, and so time-integrated sampling on filters using various types of size-selective samplers is preferred. Finally, some techniques that have been used to assess the potential for chemical contamination of the skin are presented. Biomonitoring is another tool that can be used to assess exposure, and the results are more relevant to dosimetric considerations than exposure. Biomonitoring is a complex subject worthy of a separate review, and will be considered only briefly here.  相似文献   

12.
总氮总磷在线自动监测仪的现状与问题   总被引:1,自引:1,他引:1  
李军  陈程 《中国环境监测》2013,29(2):156-158
总氮总磷在线自动监测仪已在我国水质自动监测系统中得到广泛应用。其生产厂家日趋成熟、相关标准逐步出台、仪器性能基本达标。但在实际应用过程中,该仪器仍有许多问题需要进一步认识与改进。从测定方法、国家标准、前处理、自动标定、检出限等几个方面,分析了该仪器存在的问题,并提出了相关建议。  相似文献   

13.
Measurements of aerosols were made in 2001 and 2002 at Dunhuang (40 degrees 00'N, 94 degrees 30'E), China to understand the nature of atmospheric particles over the desert areas in the Asian continent. Balloon-borne measurements with an optical particle counter suggested that particle size and concentration had noticeable peaks in super micron size range not only in the boundary mixing layer but also in the free troposphere. Super-micron particle concentration largely decreased in the mid tropopause (from 5 to 10 km; above sea level, a.s.l.). Lidar measurements made during August 2002 at Dunhuang suggested the possibility that mixing of dust particles occurred from near the ground to about 6 km even under calm weather conditions, and a large depolarization ratio of particulate matter was found in the aerosol layer. The top of the aerosol layer was found at heights of nearly 6 km (a.s.l.). It is strongly suggested that nonspherical dust particles (Kosa particles) frequently diffused in the free atmosphere over the Taklamakan desert through small-scale turbulences and are possible sources of dust particles of weak Kosa events that have been identified in the free troposphere not only in spring but also in summer over Japanese archipelago. Electron microscopic experiments of the particles collected in the free troposphere confirmed that coarse and nonspherical particles observed by the mineral particle were major components of coarse mode (diameter larger than 1 microm) below about 5 km over Dunhuang, China.  相似文献   

14.
Bioaerosol sampling by a personal rotating cup sampler CIP 10-M   总被引:1,自引:0,他引:1  
High concentrations of bioaerosols containing bacterial, fungal and biotoxinic matter are encountered in many workplaces, e.g. solid waste treatment plants, waste water treatment plants and sewage networks. A personal bioaerosol sampler, the CIP 10-M (M-microbiologic), has been developed to measure worker exposure to airborne biological agents. This sampler is battery operated; it is light and easy to wear and offers full work shift autonomy. It can sample much higher concentrations than biological impactors and limits the mechanical stress on the microorganisms. Biological particles are collected in 2 ml of liquid medium inside a rotating cup fitted with radial vanes to maintain an air flow rate of 10 l min(-1) at a rotational speed of approximately 7,000 rpm. The rotating cup is made of sterilisable material. The sampled particles follow a helicoidal trajectory as they are pushed to the surface of the liquid by centrifugal force, which creates a thin vertical liquid layer. Sterile water or another collecting liquid can be used. Three particle size selectors allow health-related aerosol fractions to be sampled according to international conventions. The sampled microbiological particles can be easily recovered for counting, incubation or further biochemical analysis, e.g., for airborne endotoxins. Its physical sampling efficiency was laboratory tested and field trials were carried out in industrial waste management conditions. The results indicate satisfactory collection efficiency, whilst experimental application has demonstrated the usefulness of the CIP 10-M personal sampler for individual bioaerosol exposure monitoring.  相似文献   

15.
Regulatory agencies commonly set standards for a myriad of chemical and physical hazards, with a special focus on carcinogens. This focus can obscure the need to update previously set standards for non-carcinogenic hazards in response to new scientific data. This paper considers n-hexane as a representative chemical hazard: the occupational standard of 500 ppm over an 8 hr time weighted average for a 40 hr week as set in 1948. In the last 12 yr, n-hexane has been shown to cause adverse effects on the peripheral and central nervous systems, the eye, and the respiratory tract. Yet, these new data have not, as yet, been incorporated into a revised standard for n-hexane. The lack of scientific data on the carcinogenicity of n-hexane may be an underlying reason explaining the failure of regulatory agencies to revise their standards. Perhaps, the most troubling problem to regulatory agencies is the sheer magnitude of the chemical regulatory burden. Research should proceed on developing meaningful categories or groupings both for the initial setting of standards and for revising existing standards.  相似文献   

16.
An understanding of the scaling laws governing aerosol sampler performance leads to new options for testing aerosol samplers at small scale in a small laboratory wind tunnel. Two methods are described in this paper. The first involves an extension of what is referred to as the "conventional" approach, in which scaled aerosol sampler systems are tested in a small wind tunnel while exposed to relatively monodisperse aerosols. Such aerosols are collected by test and reference samplers respectively and assessed gravimetrically. The new studies were carried out for a modified, low flowrate version of the IOM personal inhalable aerosol sampler. It was shown that such experiments can be carried out with a very high level of repeatability, and this supported the general validity of the aerosol sampler scaling laws. The second method involves a novel testing system and protocol for evaluating the performances of aerosol samplers. Here, scaled aerosol samplers of interest are exposed to polydisperse aerosols, again in a small wind tunnel. In this instance, the sampled particles are counted and sized using a direct-reading aerodynamic particle sizer (the APS). A prototype automated aerosol sampler testing system based on this approach was built and evaluated in preliminary experiments to determine the performance of another modified version of the IOM personal inhalable aerosol sampler. The design of the new test system accounts for the complex fluid mechanical coupling that occurs near the sampler inlet involving the transition between the external flow outside the sampler and the internal airflow inside the sampler, leading in turn to uncontrolled particle losses. The problem was overcome by the insertion of porous plastic foam plugs. where the penetration characteristics are well understood, into the entries of both the test and the reference samplers. Preliminary experiments with this new system also supported the general validity of the aerosol sampler scaling laws. In addition, they demonstrated high potential that this approach may be applied in a standardised aerosol testing method and protocol.  相似文献   

17.
The tapered element oscillating microbalance (TEOM) system is widely used to measure continuous particle mass concentrations in air quality networks. However, the semi-volatile aerosol material is lost under normal operation conditions (50 °C). This study has evaluated the error in the organic fraction of the TEOM-measured secondary organic aerosols formed from the degradation of biogenic pollutants. Experiments were carried out under controlled, water-free conditions in a fully equipped, high volume atmospheric simulator--the European PhotoReactor (EUPHORE). The ozonolysis of α-pinene, β-pinene and limonene provided a reproducible source of organic aerosol. Particulate matter concentration profiles were registered for different TEOM operating temperatures. When these values were compared with values from a filter-based gravimetric method and a scanning mobility particle sizer (SMPS), they showed that the differences between monitoring systems increased with increasing TEOM temperature. According to our results, when the TEOM is operated at 50 °C, it fails to measure 32-46% of the organic particulate material, depending on the aerosol precursor. This study has also identified and quantified the multi-oxygenated organic compounds lost in the TEOM monitoring by using a method based on the gas chromatography-mass spectrometry technique. Important losses have been calculated for relevant ambient aerosol compounds such as pinonic acid, pinonaldehyde, norpinone and limonalic acid. In conclusion, the present study has demonstrated that a high operating temperature of the TEOM monitor reduces the humidity interference but underestimates the semi-volatile organic fraction.  相似文献   

18.
An investigation of the relationship between observed nickel aerosol exposures and urinary nickel excretion was undertaken at a Scandinavian nickel refinery. The goal of the study was to assess the impact of nickel aerosol speciation, the use of particle size-selective sampling instrumentation and adjustment of urinary levels for creatinine excretion on the usefulness of urinary nickel excretion as a marker for exposure. Urinary nickel measurements and paired 'total' and inhalable aerosol exposure measurements were collected each day for one week from refinery workers in four process areas. The mean observed urinary nickel concentration was 12 micrograms L-1 (11 micrograms of Ni per g of creatinine). The strongest relationships between urinary excretion and aerosol exposure were found when urinary nickel levels were adjusted for creatinine excretion and when exposure to only soluble forms of nickel aerosol was considered. No significant difference was observed between measures of 'total' and inhalable aerosol in the ability to predict urinary excretion patterns. In the light of these results, it is recommended that consideration be given to the chemical species distribution of nickel aerosol in the use of urinary nickel measurements as a screening tool for cancer risk in occupationally-exposed populations.  相似文献   

19.
The objective of this study was to determine if there is an exposure gradient in particulate matter concentrations for people living near interstate highways, and to determine how far from the highway the gradient extends. Air samples were collected in a residential area of Greater Cincinnati in the vicinity of two major highways. The measurements were conducted at different distances from the highways by using ultrafine particle counters (measurement range: 0.02-1 microm), optical particle counters (0.3-20 microm), and PM2.5 Harvard Impactors (0.02-2.5 microm). The collected PM2.5 samples were analyzed for mass concentration, for elemental and organic carbon, and for elemental concentrations. The results show that the aerosol concentration gradient was most clearly seen in the particle number concentration measured by the ultrafine particle counters. The concentration of ultrafine particles decreased to half between the sampling points located at 50 m and 150 m downwind from the highway. Additionally, elemental analysis revealed a gradient in sulfur concentrations up to 400 m from the highway in a residential area that does not have major nearby industrial sources. This gradient was qualitatively attributed to the sulfate particle emissions from diesel engine exhausts, and was supported by the concentration data on several key elements indicative of traffic sources (road dust and diesel exhaust). As different particulate components gave different profiles of the diesel exposure gradient, these results indicate that no single element or component of diesel exhaust can be used as a surrogate for diesel exposure, but more comprehensive signature analysis is needed. This characterization is crucial especially when the exposure data are to be used in epidemiological studies.  相似文献   

20.
采用单颗粒气溶胶飞行时间质谱仪(Single Particle Aerosol Mass Spectrometer,SPAMS)对西安市大气矿尘颗粒物进行连续12 d在线分析,共采集到107 425个同时含有正负质谱信息的矿尘颗粒,矿尘颗粒物占PM_(2.5)样本数的8.44%。结果表明,矿尘颗粒物的正离子碎片成分以Na~+、K~+、Al~+、Ca~+、CaO~+、Fe~+为主,同时还含有Pb~+等,负离子碎片成分以NO~-_2和NO~-_3为主,另外还含有HSO~-_4、SiO~-_3、HSiO~-_3、H(NO_3)~-_2等。在西安市大气细颗粒物中,矿尘颗粒物中贡献较大的几类(如含钙、含铁、铁氧颗粒物等)大多是老化的成分。将观测阶段采集到的矿尘颗粒纳入本地污染源谱进行来源分析,其主要来源为扬尘源、工业源、燃煤源和汽车尾气源等。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏