首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fenamidone is an imidazolinone fungicide recently introduced in viticulture practices. This work reports the validation and assessment of global uncertainty of a gas chromatographic with mass spectrometry method to analyze fenamidone in grapes and wines. This method consists in a simple and fast liquid-liquid extraction step followed by chromatographic determination. Limits of detection for fenamidone in grapes and wines were, respectively, 0.05 mg/kg and 0.06 mg/L, precision was below 9.4% and average recovery was 89 ± 5%. In the concentration range from 0.05 to 1.00 mg/kg (or mg/L) of fenamidone, global uncertainty calculated following the EURACHEM/CITAC rules, and also by the Horwitz function, was below 25%. The EURACHEM/CITAC global uncertainty budget used gave lower estimates than those obtained from the Horwitz function.  相似文献   

2.
3.
A simple multi-residue method based on modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) approach was established for the determination of 17 organochlorine (OC), 15 organophosphorous (OP) and 7 synthetic pyrethroid (SP) pesticides in an economically important medicinal plant of India, Senna (Cassia angustifolia), by gas chromatography coupled to electron capture and flame thermionic detectors (GC/ECD/FTD) and confirmation of residues was done on gas chromatograph coupled with mass spectrometry (GC-MS). The developed method was validated by testing the following parameters: linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect, accuracy–precision and measurement uncertainty; the validation study clearly demonstrated the suitability of the method for its intended application. All pesticides showed good linearity in the range 0.01–1.0 μg mL?1 for OCs and OPs and 0.05–2.5 μg mL?1 for SPs with correlation coefficients higher than 0.98. The method gave good recoveries for most of the pesticides (70–120%) with intra-day and inter-day precision < 20% in most of the cases. The limits of detection varied from 0.003 to 0.03 mg kg?1, and the LOQs were determined as 0.01-0.049 mg kg?1. The expanded uncertainties were <30%, which was distinctively less than a maximum default value of ±50%. The proposed method was successfully applied to determine pesticide residues in 12 commercial market samples obtained from different locations in India.  相似文献   

4.
A rapid, sensitive, accurate and reliable multiresidue method for the identification and quantification of 210 relevant pesticides in four representative fruit and vegetable commodities (tomato, potato, spring onion and orange) has been developed and validated by gas chromatography in tandem with triple quadrupole mass spectrometry. The method has been fully validated and applied to 292 samples from different countries. Prior to instrumental analysis, an extraction procedure based on a sample extraction of multiclass analytes, using the ethyl acetate method was employed. Mass spectrometric conditions were individually optimized for each compound in the selected reaction monitoring (SRM) mode to achieve maximum sensitivity. The pesticides were separated in less than 25 min. This was followed by an exhaustive control of the retention times. The Retention Time Locking Method was applied, working at a constant pressure throughout the analysis. System maintenance was reduced by using a purged capillary flow device that provided backflush capabilities by reversing column flow immediately after elution of the last compound of interest. Istotopically labelled internal standards were employed to improve the quality of the analytical results.  相似文献   

5.
Continuous monitoring of ambient non-methane hydrocarbons (NMHCs) by automated gas chromatographs equipped with flame ionization detection (termed in-situ GC/FID) with hourly data resolution was instated in ozone non-attainment areas throughout Taiwan. Performance of these on-site in-situ GCs was validated by manual flask sampling, as well as by in-lab gas chromatography/mass spectrometry (GC/MS) analysis. More than 50 VOCs from C2 to C11 were analyzed by both methods. Ninety flask samples were collected in series near an in-situ GC monitoring station in order to closely compare with the in-situ measurements. Both time-series and scatter plots from the two methods are displayed and discussed. It was found that over-simplified, un-humidified single-point calibration leading to surface loss was responsible for the bias in the in-situ method, resulting in greater error in accuracy as VOC volatility decreased. Although this over-estimate of the concentrations was found across all target VOCs, both methods were able to consistently capture the variability of ambient VOCs, with R2 values greater than 0.9 for most of the major VOCs.  相似文献   

6.
The thermal decomposition of polyethylene glycol was investigated by using a technique combining evolved gas analysis (time-resolved pyrolysis) with ion-attachment mass spectrometry. This technique allows the detection of intact pyrolysis products and, therefore, offers the opportunity for direct real-time monitoring of thermal by-products. Unstable products can thus be detected; for instance, many highly reactive organic peroxides, such as CH3OOH and HOCH2OOH, were found in this study. Classification analysis revealed 10 major compositional formulas among the product species: CnH2n+2O, CnH2n+2O2, CnH2n+2O3, CnH2n+2O4, CnH2n+2O5, CnH2n+2O6, CnH2n+2O7, CnH2nO, CnH2nO2, and HO(CH2CH2O)nH ethylene glycol oligomers. The Li+ ion adduct mass spectra showed a characteristic profile in terms of both the appearance of unique components and the distribution of pyrolysis products. Among the products of the thermal decomposition of PEG, formaldehyde (HCHO) and organic peroxides were particularly interesting. Formaldehyde, one of the 10 most abundant products, is a known human carcinogen. The detection of peroxides suggests that they may form during the incineration of PEG, which may have important environmental implications. The existence of peroxide products may have implications for chemical evolution in incinerator systems.  相似文献   

7.
This paper presented a modified method for the analysis of volatile organic sulfides (VOS) simultaneously with volatile organic compounds (VOC) in wastewater using purge-and-trap with gas chromatography/ mass spectrometry. Calibration standards were prepared using filtered and nitrogen-purged VOS-free wastewater, acidified to pH 1.4. Samples were also acidified to pH 1.4. This approach minimized the oxidation of methanethiol to dimethyl disulfide (DMDS), which hampered the liquid-phase analysis of VOS. Compounds were concentrated from the liquid phase, and automated analyses were performed without additional equipment, other than that required for routine wastewater VOC analysis. The linear range was 5 to 500 microg/L, with r2 > or = 0.99. The average recovery from replicate analyses of spiked samples was 81 +/- 0.5% for methanethiol, 100 +/- 1.5% fordimethyl sulfide (DMS), and 92 +/- 1.5% for DMDS. Method detection limits were 4.8, 2.8, and 1.2 microg/L for methanethiol, DMS, and DMDS, respectively. The relative percent differences were between 0 and 8%.  相似文献   

8.
本文详细介绍了一种全新的污染物测试方法———激光质谱法的原理和特点。我们应用这一方法对机动车尾气进行了初步探测 ,得到了 2 6 6nm激光作用下汽车尾气的激光电离质谱图 ,并对摩托车发动机运行状态与苯系列污染物排放量之间的关系进行了初步的在线测量  相似文献   

9.
Mass spectrometry/mass spectrometry (MS/MS) has been demonstrated to be a valuable technique in the analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs, PCDFs). In this study, we demonstrate both the value and limitations of high-resolution mass spectrometry (HRMS) and MS/MS in the analysis of PCDDs and PCDFs. We have found that in certain cases, MS/MS can solve analytical problems that cannot be solved by high-resolution mass spectrometry and we demonstrate the reliability and reproducibility of MS/MS in the analysis of PCDDs and PCDFs in environmental matrices.  相似文献   

10.
Analytical methods for the isolation and determination of cypermethrin in milk, based on the solid-phase microextraction (SPME) and QuEChERS methods (Quick, Easy, Cheap, Effective, Rugged, and Safe) are presented. The SPME technique was not appropriate to analyse cypermethrin in milk, even establishing the best extraction conditions, polydimethylsiloxane fiber, 60 min time extraction, 60 °C temperature extraction, addition of salt (NaCl) and stirring rate. The extraction efficiency was low probably because of the matrix constituents. The QuEChERS method involves the extraction of the analyte with acetonitrile and simultaneous liquid-liquid partitioning formed by adding anhydrous MgSO4 plus NaCl, followed by the removal of residual water and cleanup using a procedure called dispersive solid-phase extraction, in which anhydrous MgSO4 plus PSA and C18 are mixed with 1 mL of acetonitrile extract. The detection and quantification limits were 0.01 and 0.04 mg kg?1, respectively, and the percentage recovery obtained ranged from 92 to 105% with relative standard deviations below 7%.  相似文献   

11.
Analytical methods for the isolation and determination of cypermethrin in milk, based on the solid-phase microextraction (SPME) and QuEChERS methods (Quick, Easy, Cheap, Effective, Rugged, and Safe) are presented. The SPME technique was not appropriate to analyse cypermethrin in milk, even establishing the best extraction conditions, polydimethylsiloxane fiber, 60 min time extraction, 60 °C temperature extraction, addition of salt (NaCl) and stirring rate. The extraction efficiency was low probably because of the matrix constituents. The QuEChERS method involves the extraction of the analyte with acetonitrile and simultaneous liquid-liquid partitioning formed by adding anhydrous MgSO(4) plus NaCl, followed by the removal of residual water and cleanup using a procedure called dispersive solid-phase extraction, in which anhydrous MgSO(4) plus PSA and C18 are mixed with 1 mL of acetonitrile extract. The detection and quantification limits were 0.01 and 0.04 mg kg(-1), respectively, and the percentage recovery obtained ranged from 92 to 105% with relative standard deviations below 7%.  相似文献   

12.
Special polychlorinated biphenyls (PCBs) standards (native and isotope labeled) were analyzed by isotope dilution method using HRGC-HRMS. Multiple analysis of special PCBs standards by three different laboratories produced the relative response factors (RRFs) and relative standard deviations (RSDs %) was in the average of 0.979 and 3.86, respectively. Additionally, inter-laboratory analysis of various forms of transformer oil revealed the PCBs concentrations were in the following order; PCBs fortified transformer oil (940-1300 ng/g)>PCB polluted transformer oil (490-680 ng/g)>chemically degraded-transformer oil (480-490 ng/g) and PCBs free oil (ND-17 ng/g). Chemical degradation resulted in an order of magnitude decrease in the PCB concentrations. Specifically, higher chlorinated PCBs degraded into lower chlorinated PCBs. Also, composition of PCBs have been determined in PCB formulations from Japan (Kanechlor), Germany (Clophen), USA (Aroclor), Russia (Sovol) and Poland (Chlorofen). Major PCBs (24-PCB congeners) contributed 54-67%, 55-68%, 16-69%, 71% and 72% in Kanechlor, Clophen, Aroclor, Sovol and Chlorofen, respectively to total PCBs. The homologue pattern of Kanechlor, Aroclor and Clophen in technical fromulation was similar (e.g., Kanechlor-300 resembled to those of Clophen A-30 and Aroclor-1242). Furthermore, congener-specific distributions of major PCBs/dioxin-like PCBs and toxic equivalency quantities (TEQ) were calculated. Based on our tentative assumption calculations, cumulative production of five different technical PCB formulations, WHO-TEQ emission was estimated to be approximately 16.05 tons.  相似文献   

13.
An analytical procedure has been developed for the determination of natural pyrethrins (pyrethrin I, pyrethrin II, jasmolin I, jasmolin II, cinerin I and cinerin II) in lemon and apricot. The QuEChERS method, which stands for quick, easy, cheap, effective, rugged and safe was used for extraction. Analysis of the extract was performed by liquid-chromatography-electrospray ionisation-tandem mass spectrometry. The ions prominent in the ESI spectra were [M+H]+ for the six compounds. A Zorbax SB-C18 column was used with a programmed gradient mobile phase consisting of (A) water containing 0.1% formic acid and 5 mM ammonium formate and (B) ACN. The method was linear within the investigated concentration range, displaying a calibration curve correlation factor of 0.99. The coefficients of variation obtained (RSD) were below 20% and the recoveries were in the 70-110% range.  相似文献   

14.
Supercritical fluid extraction (SFE) was evaluated to be applied for residue analysis of 22 gas chromatography/electron capture detector-nitrogen phosphorus detector (GC/ECD-NPD) amenable pesticides in rice, wild rice and wheat. Samples were extracted with supercritical carbon dioxide at 200 atm pressure and 50°C temperature, using methanol as a static modifier. Mean recoveries obtained with the proposed SFE method at two spiking levels with four replicates per level are compared with those obtained with an ethyl acetate-based solvent extraction/gel permeation chromatography (GPC) clean up method. Both methods gave consistent high recoveries for almost all the pesticides from all the commodities with overall mean recoveries higher than 70% with relative standard deviations lower than 20%. Remarkable exceptions were captafol and dimethoate, for which low and/or non-reproducible recoveries were obtained with the SFE method. Residue levels determined with both methods in nine different incurred samples of wheat, containing some of the studied pesticides, were very similar, but, in all cases, slightly higher levels were determined with the SFE method.  相似文献   

15.
Gas chromatography-ion trap detector (GC-ITD) was used to detect atmospheric triazines and their degradation products in the gaseous and particulate phases. Because triazines and their metabolites are expected to be present at very low concentrations and enclosed in the complex atmospheric matrix, the analytical method used was both highly selective and sensitive. These two properties were obtained by associating chromatography with ion trap tandem mass spectrometry (GC-ITD (MS/MS)). To develop this method, a comparison between the two ionization modes (electron impact and positive-chemical-ionisation) in single-MS was first conducted to choose the parent ions of the five target analytes, i.e. atrazine, desethylatrazine, deisopropylatrazine, terbuthylazine and desethylterbuthylazine. Then, a MS/MS method was optimised by parameters such as the radio frequency storage level and the collision-induced dissociation excitation voltage. Finally, a last step enabled the development of a calibrating program based on the quantification of daughter ions. With this analytical procedure, the detection limits varied between 0.8 and 15 pg m(-3) depending on the compounds under study. This method was tested with success for four atmospheric samples collected in Strasbourg (France) in which four of the five target compounds were detected.  相似文献   

16.
Endocrine disrupting compounds (EDCs) and pharmaceuticals and personal care products (PPCPs) have been globally detected in impacted natural waters. The detection of trace quantities of EDCs and PPCPs in the environment is of great concern since some of these compounds have known physiological responses at low concentrations. EDCs can have a wide range of polarities, acidic and basic moieties, and exist in trace quantities, which often requires numerous complex extractions, large sample collection volumes, and multiple instrumental analyses. A comprehensive method has been developed allowing for the analysis of 58 potential EDCs in various water matrices using a single solid-phase extraction (SPE) of a 1 L sample with subsequent analyses using both gas chromatography and liquid chromatography, each coupled with tandem mass spectrometry (GC–MS/MS and LC–MS/MS). Instrument detection limits ranged between 0.12–7.5 pg with corresponding method reporting limits of 1–10 ng l−1 in water. Recoveries for most compounds were between 50% and 112% with good reproducibility (RSD 6–22%).  相似文献   

17.
A gas chromatograph/electron capture detector-ion trap mass spectrometer (GC/ECD-ITMS) was used for the determination of polybrominated diphenyl ethers (PBDEs) in euryhaline fish and crabs. GC/ECD-ITMS results showed that average recoveries from the spiked fish samples are in a range of 58-123% with relative standard deviations (RSDs) of 5-19%. PBDE concentrations obtained from GC/ECD-ITMS ranged from 28 ng/g to 1845 ng/g lipid weight (lw) in all aquatic species collected from Hawaiian brackish waters. The general BDE congener concentration profile observed in this study is BDE-47 > BDE-100 > BDE-154 > BDE-99 > BDE-153 > BDE-28 > BDE-183. The ELISA results expressed as BDE-47 equivalents correlated well with those of GC/ECD-ITMS, with a correlation coefficient (R2 = 0.68) and regression coefficient (slope = 0.82). Comparison of ELISA with GC/ECD-ITMS results demonstrated that ELISA provides a timely and cost-effective method to screen PBDEs in fish and crab samples.  相似文献   

18.
An efficient and reliable GC-MS/MS method for the multiresidue determination of pesticides in tea was developed by modifying the Japanese official multiresidue method. Sample preparation was carefully optimized for the efficient removal of coextracted matrix components. The optimal sample preparation procedure involved swelling of the sample in water; extraction with acetonitrile; removal of water by salting-out; and sequential cleanup by ODS, graphitized carbon black/primary secondary amine (GCB/PSA) and silica gel cartridges prior to GC-MS/MS analysis. The recoveries of 162 pesticides from fortified (at 0.01 mg kg?1) green tea, oolong tea, black tea and matcha (powdered green tea) were mostly (95–98% of the tested pesticides) within the range of 70–120%, with relative standard deviations of <20%. Poor recovery of triazole pesticides was considered to be due to low recovery from the silica gel cartridges. The test solutions obtained by the modified method contained relatively small amounts of pigments, caffeine and other matrix components and were cleaner than those obtained by the original Japanese official multiresidue method. No interfering peaks were observed in the blank chromatograms, indicating the high selectivity of the modified method. The overall results suggest that the developed method is suitable for the quantitative analysis of GC-amenable pesticide residues in tea.  相似文献   

19.
《Chemosphere》1996,32(6):1103-1115
Capillary gas chromatography (GC) combined with mass spectrometry (MS) and atomic emission spectroscopy (AED) was utilized for a comprehensive investigation of organic micropollutants in a marine sediment. Most compounds were found and identified by GC-MS library search. The elemental information from GC-AED was utilized for confirmation purposes, for analyte characterization in cases where identification by GC-MS was impossible, and for screening on heteroatomic components. In addition, GC-AED was effectively used for the quantitative part, where the total amount of GC amenable material, classes of compounds, and individual components were determined.  相似文献   

20.
A method for the determination of polybrominated diphenyl ethers (PBDEs) in biota for routine analysis is described. The mass spectroscopic (MS) evaluation of 23 brominated diphenyl ethers, under electron ionization and electron capture negative ion conditions using magnetic sector and quadrupole mass spectrometers, showed that high-resolution mass spectrometry (HRMS) under electron ionization conditions was the most reliable technique, with high selectivity and adequate sensitivity. The instrument detection limit for this method ranged for individual congeners between 4.8 and 0.1 pg for 3-bromodiphenyl ether (BDE-2) and 2,3',4,4'-tetrabromodiphenyl ether (BDE-66), respectively, and method detection limit for each homologue group ranged between 5 pg/g for salmon certified reference material (CRM) and 93 pg/g for lake trout CRM. The effectiveness of this method was evaluated by analyzing the occurrence of PBDEs in commercially available CRMs comprising Lake Ontario lake trout, Pacific herring, and sockeye salmon. The average coefficients of variation for the replicate analyses of PDBEs in several tissue samples were: 25% for lake trout, 36% for Pacific herring, and 34% for sockeye salmon. The average deviations in the inter-laboratory study were: 14% for lake trout, 15% for Pacific herring, and 37% for sockeye salmon. Results indicated that the described method, based on gas chromatography/high-resolution mass spectrometry, is reliable for determining PBDE concentrations in biological tissues.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号