首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
In order to improve the process performance regarding the removal of organics, nitrogen, and an odor-causing compound (sulfide) contained in domestic wastewater, an entrapped-mixed-microbial cell (EMMC) with and without humic substances for both fixed and moving carrier reactors and conventional suspended growth culture (i.e. conventional activated sludge process) were investigated simultaneously. Both synthetic (simulated to the organics concentration of general domestic sewage) and actual domestic wastewater were investigated under operational conditions of 12 h of hydraulic retention time (HRT) with 1 h of aeration and 1 h of non-aeration, and 6 h of HRT with continuous aeration, at a room temperature of 25 +/- 2 degrees C. It was found that entrapping humic substances in the EMMC carriers had no impact on the removal of organics, nitrogen, and the odor-producing compound. Additionally, the performance of the EMMC moving carrier system for the removal of these pollutants is similar to that of the EMMC fixed carrier system. In general, the EMMC associated systems which provide high solids retention time achieve a better removal of chemical oxygen demand (COD), nitrogen, and the odor-producing substance than the suspended growth system for both HRTs of 6 h (continuous aeration) and 12 h (1 h of aeration and 1 h of non-aeration). Both the fixed and moving carrier EMMC processes, therefore, have the potential for improvement or replacement of the existing conventional activated sludge process with regard to improving the effluent qualities (such as COD, nitrogen and odor-producing compound) for reuse/disposal.  相似文献   

2.
Treatment of low-strength soluble wastewater (COD approximately 500 mg/L) was studied using an eight chambered anaerobic baffled reactor (ABR). At pseudo steady-state (PSS), the average total and soluble COD values (COD(T) and COD(S)) at 8h hydraulic retention time (HRT) were found to be around 50 and 40 mg/L, respectively, while at 10h HRT average COD(T) and COD(S) values were of the order of 47 and 37 mg/L, respectively. COD and BOD (3 day, 27 degrees C) removal averaged more than 90%. Effluent conformed to Indian standards laid down for BOD (less than 30 mg/L). Reactor effluent characteristics exhibited very low values of standard deviation indicating excellent reactor stability at PSS in terms of effluent characteristics. Based on mass balance calculations, more than 60% of raw wastewater COD was estimated to be recovered as CH(4) in the gas phase. Compartment-wise profiles indicated that most of the BOD and COD got reduced in the initial compartments only. Sudden drop in pH (7.8-6.7) and formation of volatile fatty acids (VFA) (53-85 mg/L) were observed in the first compartment due to acidogenesis and acetogenesis. The pH increased and VFA concentration decreased longitudinally down the reactor. Residence time distribution (RTD) studies revealed that the flow pattern in the ABR was neither completely plug-flow nor perfectly mixed. Observations from scanning electron micrographs (SEM) suggest that distinct phase separation takes place in an ABR.  相似文献   

3.
An integrated system, consisting of Up-flow Anaerobic Sludge Blanket (UASB)-duckweed-tilapia ponds was used for recovery of sewage nutrients and water recycling. A UASB reactor with 40 liter working volume was used as pre-treatment unit followed by a series of three duckweed ponds for nitrogen recovery. The treated effluent and duckweed biomass was used to feed fishponds stocked with Nile tilapia (Oreochromis niloticus). The UASB reactor was fed with raw, domestic sewage at 6 h hydraulic retention time. The three duckweed ponds were stocked with Lemna gibba and fed with UASB effluent at 15 days hydraulic retention time. Nitrogen recovery from UASB effluent via duckweed biomass represented 81% of total nitrogen removal and 46.5% from the total nitrogen input to the system. In subsequent fishponds the nitrogen recovery from duckweed as fish feed was in the range of 13.4–20%. This nitrogen in fish biomass represented 10.6–11.5 g N from the total nitrogen in the raw sewage fed to the UASB reactor. The growth performance of tilapia (Oreochromis niloticus) showed specific growth rates (SGR) in the range of 0.53–0.97. The range of feed conversion ratio (FCR) and protein efficiency ratio (PER) were 1.2–2.2 and 2.1–2.28, respectively. The results of the experiments showed total fish yield and net fish yield in the range of 17–22.8 ton/ha/y and 11.8–15.7 ton/ha/y respectively. In conclusion UASB-duckweed-tilapia ponds provide marketable by-products in the form of duckweed and fish protein, which represent a cost recovery for sewage treatment.  相似文献   

4.
With the increase of urbanization, municipal solid waste has also increased. Therefore, the need for solid waste management is also increasing compared with earlier decades. Composting is a good option for the recycling of solid waste; however, it produces leachate, which requires proper treatment systems to prevent environmental degradation. Due to high chemical oxygen demand (COD) concentrations in compost leachate, anaerobic treatment is the best option for handling the effluent, and an anaerobic baffled reactor (ABR) is one such anaerobic reactor that can be used for its treatment. Because of high ammonia and heavy metal concentrations, as well as the possibility of sludge washout in ABRs, it is important to use proper media, such as zeolite, which can reduce inhibition effects and sludge washout from the reactor. Anaerobic treatment, especially during the methanogenesis phase, is sensitive, and pH and alkalinity are parameters that influence the treatment. Therefore, adjusting these parameters within a normal range is very important to the proper functioning of anaerobic systems. In this study, a pilot‐scale ABR was used, and the last 4 of the 8 ABR compartments were filled with zeolite. The bioreactor was operated at hydraulic retention times (HRT) of 3, 4, and 5 days, with zeolite filling ratios of 10%, 20%, and 30%, and influent COD concentrations of 10,000, 20,000, and 30,000 milligrams per liter (mg/L). In this study, pH value was 6.43 ± 0.1, 6.96 ± 0.3, and 6.96 ± 0.25 at filling ratios of 10%, 20%, and 30%, respectively. According to the results, in all filling ratios, no significant changes were observed in the pH value when the organic loading rate increased and its amount was within a constant range. Influent alkalinity was equal to 2015 ± 510, 2884 ± 505, and 4154 ± 233 milligrams of calcium carbonate per liter (mg CaCO3/L) at influent COD concentrations of 10,000, 20,000, and 30,000 mg/L, respectively, and in effluent, they were 2536 ± 336, 3379 ± 639, and 4377 ± 325 mg CaCO3/L, respectively. The amount of alkalinity in the effluent increased compared with the alkalinity in the influent. The results show that the amount of alkalinity in the influent and effluent was similar, and the alkalinity enhancement was lower when the filling ratio was increased from 10% to 20%, and 20% to 30%. Comparisons of the results from zeolite with and without biofilm showed that, in cases of zeolite with biofilm, the amounts of silica and oxygen decreased and the amount of carbon increased, and it showed the formation of biofilm on the surface of zeolite. In addition, the absence of sodium in the zeolite with the biofilm indicated that sodium was exchanged with ammonium ions. According to the results, zeolite can be used in anaerobic reactors as a medium, and it also reduces fluctuations in pH and alkalinity at different organic loading rates, providing a normal range for anaerobic treatment.  相似文献   

5.
Constructed wetlands (CW) usually require large land areas for treating wastewater. This study evaluated the feasibility of applying CW with less land requirement by operating a group of microcosm wetlands at a hydraulic retention time (HRT) of less than 4 d in southern Taiwan. An artificial wastewater, simulating municipal wastewater containing 200 mg L(-1) of chemical oxygen demand (COD), 20 mg L(-1) of NH4+-N (AN), and 20 mg L(-1) of PO4(3-)-P (OP), was the inflow source. Three emergent plants [reed, Phragmites australis (Cav.) Trin. ex Steud.; water primrose, Ludwigia octovalvis (Jacq.) P.H. Raven; and dayflower, Commelina communis L.] and two floating plants [water spinach, Ipomoea aquatica Forssk.; and water lettuce, Pistia stratiotes L.] plants were tested. The planted systems showed more nutrient removal than unplanted systems; however, the type of macrophytes in CW did not make a major difference in treatment. At the HRTs of 2 to 4 d, the planted system maintained greater than 72,80, and 46% removal for COD, AN, and OP, respectively. For AN and OP removal, the highest efficiencies occurred at the HRT of 3 d, whereas maximum removal rates for AN and OP occurred at the HRT of 2 d. Both removal rates and efficiencies were reduced drastically at the HRT of 1 d. Removals of COD, OP, and AN followed first-order reactions within the HRTs of 1 to 4 d. The efficient removals of these constituents obtained with HRT between 2 and 4 d indicated the possibility of using a CW system for wastewater treatment with less land requirement.  相似文献   

6.
The performance of polyurethane rotating discs (RBC-1) versus polystyrene rotating discs (RBC-2) for the treatment of an up-flow anaerobic sludge blanket (UASB) reactor effluent fed with domestic wastewater was investigated. Both RBC units were operated at the same organic loading rate (OLR) of 10.5 gCOD/m2 d. and a hydraulic retention time (HRT) of 2.5 h. The residual values of COD fractions (CODsuspended, CODcolloidal and CODsoluble) in the treated effluent of RBC-1 and RBC-2 were similar. However, the removal efficiency of ammonia in the RBC-1 (87 ± 4%) was significantly higher than that found for RBC-2 i.e. 24 ± 6%. Moreover, RBC-1 achieved a substantial removal efficiency of 99.0 ± 1% for Escherichia coli (E. coli), while RBC-2 removed 91.2 ± 0.3%. Based on these results, optimization of RBC-1 treating UASB reactor effluent was extensively performed. The RBC-1 was operated at an OLR's of 4.0, 11 and 23 gCOD/m2 d. The results obtained showed that increasing the OLR from 11.0 to 23.0 gCOD/m2 d and decreasing the HRT from 2.5 to 1.25 h significantly declined the effluent quality of CODtotal and ammonia. However, the residual values of CODtotal and ammonia remained unaffected when increasing the OLR from 4.0 to 11.0 gCOD/m2 d and by decreasing the HRT from 5 to 2.5 h. Bacteriological examination showed that the mean residual count of E. coli remained at a level of 104/100 ml, in the effluent of RBC-1 independent on the imposed HRT. Accordingly, it is recommended to operate RBC-1 for treatment of anaerobically pre-treated sewage at an OLR of 11 gCOD/m2 d and an HRT of 2.5 h.A feed-less (ammonia limitation) period of 9.0 days followed by 9.0 days feeding with high OLR of 26 gCOD/m2 d. (raw sewage) was investigated to elaborate, if the nitrifiers of the RBC-1 are capable to convert ammonia to nitrate after totally 18 days when retuning back to the normal operating conditions. The results of the experiment clearly show a strong and immediate detrimental effect of imposing high OLR of 26 gCOD/m2 d on the nitrification process in the nitrifying RBC unit. However, after returning back to the original OLR of 10.6 gCOD/m2 d, the nitrification efficiency in the RBC unit was recovered within 2–3 days.  相似文献   

7.
In the present study, decolorization of a simulated dye waste containing three different triphenylmethane (TPM) dyes--Magenta, Malachite Green and Crystal Violet, was investigated in a laboratory scale, two-stage anaerobic high-rate reactor. The effect of various parameters (influent dye concentration, hydraulic and co-substrate loading rates) on color and COD removal efficiency of the reactor has been studied. It has been shown that the influent dye concentration had little effect on overall COD and color removal efficiency. More than 99% color removal and 96% COD removal efficiency were maintained even at a dye concentration of 500 mg/l and a dye loading rate of 1000 mg/l day. However, a minimum level of glucose as supplementary carbon source is required to maintain the maximum color removal efficiency and it drops appreciably when no glucose is added to the influent. The study also showed that the acidogenic phase of the reaction plays an important role in decolorization of the TPM dyes. In addition, the two-stage anaerobic reactor was observed to have distinct advantages over the single-stage system, as the drop in color and COD removal efficiency of stage 1 are adequately compensated by stage 2 of the reactor especially under high dye loading rates accompanied by low co-substrate loading and under reduced HRTs.  相似文献   

8.
A bench-scale experimental study was carried out to investigate the overall performance of a combined anaerobic reactor for treating pre-settled municipal wastewater at ambient temperature (18–28°C) in terms of substrate removal efficiencies, biogas, methane production, volatile fatty acid (VFA) profiles and effluent suspended solids (SS) concentration, etc. The tested reactor was a modified anaerobic baffled reactor (ABR). The second and third compartments were partly packed with supporting media. The experimental results were similar to, or compared favourably with, other anaerobic reactor systems for municipal wastewater treatment at ambient temperature and proved the technical feasibility of this compartmentalised reactor. Considering its simple structure and operation, it could be considered a potential reactor system for treating municipal and domestic wastewaters in tropical and sub-tropical areas of developing countries.  相似文献   

9.
Regeneration studies of wastewater effluent from an organized industrial district (OID) for possible reuse in textile industry as process water was investigated. Advanced treatment methods including Fenton process, polyaluminium chloride (PAC) coagulation and ion exchange were applied on OID effluent. In Fenton process removal efficiencies for suspended solids (SS), chemical oxygen demand (COD), SAC436 (spectral absorption coefficient), SAC525 and SAC620 were determined 61%, 36%, 35%, 49% and 67%, respectively. After Fenton process, wastewater samples were coagulated with PAC. Optimum removal efficiencies for SS, COD, Fe ion, SAC436, SAC525 and SAC620 were determined 83%, 18%, 93%, 32%, 36% and 58%, respectively. Ion exchange experiments were conducted on chemically coagulated wastewater samples to improve the quality of wastewater. Optimum dosage of resins was determined. The experiments revealed that 1:1 resin ratio (20 mL H-type resin:20 mL OH-type resin) gave the best removal rates for the parameters considered in this study. Study results indicated that quality of the wastewater was suitable for the process water characteristics of textile industry and unit wastewater treatment cost was determined as 2.54 €/m3.  相似文献   

10.
以奇台太极华力食品有限公司番茄废水处理工程实例为依据,介绍了采用ABR厌氧+完全混合活性污泥法工艺在处理番茄加工废水的设计、调试及运行情况。经过2年运行,其进水COD在700~1 500mg/L之间,最大处理水量达到4 000m3/d;出水COD在40~70mg/L之间,COD去除率达到97%。处理出水可以稳定达到污水综合排放二级标准。ABR+完全混合活性污泥法工艺具有启动快,调试时间短,工程造价低的优点,尤其适宜处理番茄等间歇时间长工作时间短的季节性生产污水。  相似文献   

11.
The production of highly polluting palm oil mill effluent (POME) has resulted in serious environmental hazards. While anaerobic digestion is widely accepted as an effective method for the treatment of POME, anaerobic treatment of POME alone has difficulty meeting discharge limits due to the high organic strength of POME. Hence, subsequent post-treatment following aerobic treatment is vital to meet the discharge limits. The objective of the present study is to investigate the aerobic treatment of anaerobically digested POME by using a sequencing batch reactor (SBR). The SBR performance was assessed by measuring Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD) and Total Suspended Solids (TSS) removal as well as Sludge Volume Index (SVI). The operating pH and dissolved oxygen concentrations were found to be 8.25–9.14 and 1.5–6.4 mg/L, respectively, throughout the experiment. The experimental results demonstrate that MLVSS, OLR and sludge loading rate (SLR) play a significant role in the organic removal efficiency of SBR systems and therefore, further investigation on these parameters was conducted to attain optimum SBR performance. Maximum COD (95–96%), BOD (97–98%) and TSS (98–99%) removal efficiencies were achieved at optimum OLR, SLR and MLVSS concentration ranges of 1.8–4.2 kg COD/m3 day, 2.5–4.6 kg TSS/m3 day and 22,000–25,000 mg/L, respectively. The effluent quality remained stable and complied with the discharge limit. At the same time, the sludge showed good settling properties with average SVI of 65. It is envisaged that the SBR process could complement the anaerobic treatment to produce final treated effluent which meets the discharge limit.  相似文献   

12.
笔者从稳定塘结构与净化机理研究,结合厌氧生物膜法、吸附过滤法和稳定塘技术,提出稳定塘工艺改良技术—生物滤塘。本文通过对生物滤塘与传统稳定塘进行对比试验分析,结果表明:当水力停留时间相同时,生物滤塘较传统稳定塘具有较高的COD、NH3-N和TP去除效率,有机负荷调试试验中,当COD浓度达800mg/L时,生物滤塘仍然保持较好的运行状态,COD平均去除率较稳定塘提高了28.8%。  相似文献   

13.
Seaweed can be anaerobically digested for the production of energy-rich methane. However, the use of seaweed digestate as a fertilizer may be restricted because of the high heavy metal content especially cadmium. Reducing the concentration of heavy metals in the digestate will enable its use as a fertilizer. In this laboratory-scale study, the potential of seaweed and its leachate in the production of methane were evaluated in batch tests. The effect of removing the heavy metals from seaweed leachate was evaluated in both batch test and treatment in an upflow anaerobic sludge blanket (UASB) reactor. The heavy metals were removed from seaweed leachate using an imminodiacetic acid (IDA) polyacrylamide cryogel carrier. The methane yield obtained in the anaerobic digestion of seaweed was 0.12 N l CH4/g VSadded. The same methane yield was obtained when the seaweed leachate was used for methane production. The IDA-cryogel carrier was efficient in removing Cd2+, Cu2+, Ni2+ and Zn2+ ions from seaweed leachate. The removal of heavy metals in the seaweed leachate led to a decrease in the methane yield. The maximum sustainable organic loading rate (OLR) attained in the UASB reactor was 20.6 g tCOD/l/day corresponding to a hydraulic retention time (HRT) of 12 h and with a total COD removal efficiency of about 81%. Hydrolysis and treatment with IDA cryogel reduced the heavy metals content in the seaweed leachate before methane production. This study also demonstrated the suitability of the treatment of seaweed leachate in a UASB reactor.  相似文献   

14.
To reduce the consumption of freshwater in the laundry industry, a new trend of closing the water cycle has resulted in the reuse/recycling of water. In this study, the performance of a full-scale submerged aerobic membrane bioreactor (9 m3) used to treat/reuse industrial laundry wastewater was examined over a period of 288 days. The turbidity and total solids (TS) were reduced by 99%, and the chemical oxygen demand (COD) effluent removal efficiencies were between 70% and 99%. The levels of COD removed by the membrane were significantly greater than the levels of biodegraded COD. This enabled the bioreactor to sustain COD levels that were below 100 mg/L, even during periods of low wastewater biodegradation due to bioreactor sludge. An economic evaluation of the membrane bioreactor (MBR) system showed a savings of 1.13 € per 1 m3 of water. The payback period for this system is approximately 6 years. The energy and maintenance costs represent only 5% of the total cost of the MBR system.  相似文献   

15.
The objective of this work was to analyze the effect of the interaction between feeding strategy and COD/sulfate ratio on the removal efficiency of sulfate and organic matter from a synthetic wastewater. An anaerobic sequencing batch reactor with recirculation of the liquid phase and containing immobilized biomass on polyurethane foam (AnSBBR) was used. The AnSBBR with a total volume of 3.7 L, treated 2.0 L synthetic wastewater in 8-h cycles at 30 ± 1 °C and was inoculated with anaerobic biomass from a UASB. Two feeding strategies were assessed: (a) batch and (b) batch followed by fed-batch. In strategy (a) the reactor was fed in 10 min with 2 L wastewater containing sulfate and carbon sources. In strategy (b) 1.2 L wastewater (containing only the sulfate source) was fed during the first 10 min of the cycle and the remaining 0.8 L (containing only the carbon source) in 240 min. The COD/sulfate ratios assessed were 1 and 3. Based on these values and on the concentrations of organic matter (0.5–11.25 gCOD/L) and sulfate (0.5 and 2.5 gSO42?/L), the sulfate and organic matter loading rates applied equaled 1.5 and 4.5 gSO42?/L d for sulfate and 1.5, 4.5 and 13.5 gCOD/L d for organic matter. After stabilization of the system time profiles were run of monitored parameters (COD, sulfate, sulfide and sulfite). In general, the reactor showed to be robust for use in the anaerobic treatment of wastewaters containing sulfate. Gradual feeding (strategy b) of the carbon source favored sulfate reduction, resulting in sulfate removal efficiencies of 84–98% and organic matter removal efficiencies of 48–95%. The best results were observed under COD/sulfate ratio equal to 1 (loading rates of 1.5 and 4.5 gSO42?/L d for sulfate, and 1.5 and 4.5 gCOD/L d for organic matter). When COD/sulfate ratio was 3 (loading rates of 1.5 and 4.5 gSO42?/L d for sulfate, and 4.5 and 13.5 gCOD/L d for organic matter) the effect of feed mode became less significant. These results show that the strategy batch followed by fed-batch is more advantageous for COD/sulfate ratios near the stoichiometric value (0.67) and higher organic matter and sulfate concentrations.  相似文献   

16.
张璇  曾鸿鹄 《四川环境》2009,28(1):11-13
本文研究了水解酸化处理糖蜜酒精废水的效果。结果表明在此条件下,对糖蜜酒精废水的处理比完全厌氧处理有优越性。在水力停留时间为8h时,出水VFA最大,而后趋于平缓。但也不难看出对COD的去除效果并不是很明显。水解酸化作为有效的预处理阶段,可明显提高高浓度有机废水的可生物降解性,为后续处理减轻负担。  相似文献   

17.
A conventional activated sludge treatment facility was the subject of this study. The assessment was directed at determining the characteristics of the raw wastewater, the quality of the treated effluent and the efficiency of the various treatment units. Furthermore, the water quality along the effluent irrigation canal was monitored. The assessment of the quality of the treated effluent for irrigation is based on the guidelines established by the World Health Organization and the Egyptian decree 9/89 for the use of wastewater in agriculture. The results of the study indicated that the concentration of the raw wastewater was considered moderate. The mean values of the COD (Chemical Oxygen Demand), BOD (Biological Oxygen Demand) and total suspended solids (TSS) were around 250, 102 and 142 mg l–1, respectively. This was attributed to the high quantities of wastewater from industrial sources. The overall efficiency of the treatment facility was good. The mean residual COD, BOD and TSS were 25, 8 and 21 mg l–1 and the corresponding percentage removal values were 90, 92 and 85%, respectively. The maximum percentage removal of oil and grease was 84% with a mean residual concentration of 24 mg l–1. The total viable count (22°C and 37°C), faecal coliform and aecal streptococci were reduced by 99.9% compared to only 99.5% for Salmonella. Bacteriological examination of the dried sludge indicated a reduction of nine logs of faecal coliform and faecal streptococci, as compared to thickened sludge. Analysis of the Ni, Cu, Pb and Cr in the dried sludge indicated that their concentrations are within the permissible limits. Zinc exceeded the consent standards by 50%. The results of the analyses of samples collected at the beginning of the irrigation canal indicated insignificant changes from the characteristics of the final effluent. Samples collected at a distance of 2km along the irrigation canal showed mean reductions in the COD and BOD of 28.6 and 47%, respectively, which could be attributed to sedimentation and/or a self-purification effect. An increase in the total nitrogen, total phosphorus and total viable count was also recorded, which could be due to seepage from the agricultural land. From the data available it is evident that the treated wastewater could be used for restricted irrigation. The design and implementation of a monitoring programme is recommended.  相似文献   

18.
The performance of an upflow anaerobic sludge blanket (UASB) reactor treating 2,4 dichlorophenol (2,4 DCP) was evaluated at different hydraulic retention times (HRTs) using synthetic wastewater in order to obtain the growth substrate (glucose-COD) and 2,4 DCP removal kinetics. Treatment efficiencies of the UASB reactor were investigated at different hydraulic retention times (2-20 h) corresponding to a food to mass (F/M) ratio of 1.2-1.92 g-COD g(-1) VSS day(-1). A total of 65-83% COD removal efficiencies were obtained at HRTs of 2-20 h. In all, 83% and 99% 2,4 DCP removals were achieved at the same HRTs in the UASB reactor. Conventional Monod, Grau Second-order and Modified Stover-Kincannon models were applied to determine the substrate removal kinetics of the UASB reactor. The experimental data obtained from the kinetic models showed that the Monod kinetic model is more appropriate for correlating the substrate removals compared to the other models for the UASB reactor. The maximum specific substrate utilization rate (k) (mg-COD mg(-1) SS day(-1)), half-velocity concentration (K(s)) (mg COD l(-1)), growth yield coefficient (Y) (mg mg(-1)) and bacterial decay coefficient (b) (day(-1)) were 0.954 mg-COD mg(-1) SS day(-1), 560.29 mg-COD l(-1), 0.78 mg-SS g(-1)-COD, 0.093 day(-1) in the Conventional Monod kinetic model. The second-order kinetic coefficient (k(2)) was calculated as 0.26 day(-1) in the Grau reaction kinetic model. The maximum COD removal rate constant (U(max)) and saturation value (K(B)) were calculated as 7.502 mg CODl(-1)day(-1) and 34.56 mg l(-1)day(-1) in the Modified Stover-Kincannon Model. The (k)(mg-2,4 DCP mg(-1) SS day(-1)), (K(s)) (mg 2,4 DCPl(-1)), (Y) (mg SS mg(-1) 2,4 DCP) and (k(d)) (day(-1)) were 0.0041 mg-2,4 DCP mg(-1) SS day(-1), 2.06 mg-COD l(-1), 0.0017 mg-SS mg(-1) 2,4 DCP and 3.1 x 10(-5) day(-1) in the Conventional Monod kinetic model for 2,4 DCP degradation. The second-order kinetic coefficient (k(2)) was calculated as 0.30 day(-1) in the Grau reaction kinetic model. The maximum 2,4 DCP removal rate constant (U(max)) and saturation value (K(B)) were calculated as 0.01 mg COD l(-1) day(-1) and 9.8 x 10(-3) mg l(-1) day(-1) in the Modified Stover-Kincannon model.  相似文献   

19.
唐奕  黄健盛  杨皓洁  李翔  杨平 《四川环境》2009,28(6):41-44,49
开发一种改进型生物转盘处理生活污水,将盘片改为转笼状,并向其中加入颗粒活性发作为载体,研究该系统对生活污水的处理效果。结果表明:在转盘转速为15rpm和HRT分别为10h、8h、6h、4.5h情况下,进水COD平均浓度约为223mg/L,出水COD平均浓度分别为15.6、17.9、23.4、28.2mg/L,平均去除率为93.0%、91.9%、89.5%、86.6%;进水NH3-N平均浓度约为22mg/L,出水NH3-N平均浓度分别为0.32、1.13、2.30、5.71mg/L,平均去除率为98.5%、94.8%、89.7%、74.6%。  相似文献   

20.
Biogas production from a slurry obtained by mixing finely ground olive pomace in water was investigated using anaerobic digesters of 1-l working volume at 37°C. A start-up culture was obtained from a local landfill area and was adopted to the slurry within 10 days at this temperature. The biogas generation rates were determined by varying the total solids (TS) concentration in the slurry and the hydraulic retention time (HRT) during semi-continuous digestion. The maximum rate was found to be 0.70 l of biogas per l of digester volume per day, corresponding to a HRT of 20 days and 10% TS with a yield of 0.08 l biogas per g chemical oxygen demand (COD) added to the digester. The methane content of the biogas was in the range of 75–80% for both batch and semi-continuous runs, the remainder being principally carbon dioxide.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号