首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 435 毫秒
1.
A moving bio-film (MB), made from the inner tube of used tyres was applied in a conventional-aerobic-SBR for increasing the system efficiency and quality of bio-sludge due to good sedimentation (the density of 1.925+/-0.21 g/cm(3)), non-biodegradability and re-usability of the media without any regeneration. The total bio-sludge mass of the MB-aerobic-SBR was about 30% higher than that of the conventional-aerobic-SBR resulting in a reduction of the F/M value of the system and amount of suspended bio-sludge waste. The amount of suspended bio-sludge waste, SVI and SRT of the MB-aerobic-SBR under a low organic loading of 80+/-9.3g BOD(5)/m(3)-d were 1,485+/-146 mg/d, 51+/-3.7 ml/g and 10.1+/-5.1 days, respectively while they were 1,800+/-152 mg/d, 69+/-4.0 ml/g and 8.3+/-5.3 days, respectively in the conventional-aerobic-SBR. The BOD(5), TKN and TP removal efficiencies of the MB-aerobic-SBR were about 1-2, 2-3 and 10-12% higher, respectively, than that of the conventional-aerobic-SBR. Also, the BOD(5) and COD removal efficiencies of the MB-aerobic-SBR were higher than 95% even when the system was operated with synthetic wastewater containing 800 mg/l BOD(5) under a very low HRT of 1.5 days (organic loading of 528+/-50.8 g BOD(5)/m(3)-d). The effluent BOD(5), COD, total kjeldahl nitrogen, total phosphorus and suspended solids of the MB-aerobic-SBR under a high organic loading of 528+/-50.8 g BOD(5)/m(3)-d were 45+/-5.1, 37+/-3.6, 4.1+/-1.0, 1.5+/-0.80 and 41+/-2mg/l, respectively.  相似文献   

2.
A sequencing batch reactor biofilm (MSBR) system was modified from the conventional sequencing batch reactor (SBR) system by installing 2.7 m2 surface area of plastic media on the bottom of the reactor to increase the system efficiency and bio-sludge quality by increasing the bio-sludge in the system. The COD, BOD5, total kjeldahl nitrogen (TKN) and oil & grease removal efficiencies of the MSBR system, under a high organic loading of 1340 g BOD5/m3 d, were 89.3+/-0.1, 83.0+/-0.2, 59.4+/-0.8, and 82.4+/-0.4%, respectively, while they were only 87.0+/-0.2, 79.9+/-0.3, 48.7+/-1.7 and 79.3+/-10%, respectively, in the conventional SBR system. The amount of excess bio-sludge in the MSBR system was about 3 times lower than that in the conventional SBR system. The sludge volume index (SVI) of the MSBR system was lower than 100 ml/g under an organic loading of up to 1340 g BOD5/m3 d. However, the MSBR under an organic loading of 680 g BOD5/m3 d gave the highest COD, BOD5, TKN and oil & grease removal efficiencies of 97.9+/-0.0, 97.9+/-0.1, 79.3+/-1.0 and 94.8+/-0.5%, respectively, without any excess bio-sludge waste. The SVI of suspended bio-sludge in the MSBR system was only 44+/-3.4 ml/g under an organic loading of 680 g BOD5/m3 d.  相似文献   

3.
Due to the toxic nature of chlorophenol compounds present in some chemical industry effluents, biological treatment of such wastewaters is usually realized with low treatment efficiencies. Para-chlorophenol (4-chlorophenol, 4-CP) containing synthetic wastewater was treated in an activated sludge unit at different hydraulic residence times (HRT) varying between 5 and 30 h while the feed COD (2500 mg l(-1)), 4-CP (500 mg l(-1)) and sludge age (SRT, 10 days) were constant. Effects of HRT variations on COD, 4-CP, toxicity removals and on settling characteristics of the sludge were investigated. Percent COD removals increased and the effluent COD concentrations decreased when HRT increased from 5 to 15 h and remained almost constant for larger HRT levels. Nearly, 91% COD and 99% 4-CP removals were obtained at HRT levels above 15 h. Because of the highly concentrated microbial population at HRT levels of above 15 h, low effluent (reactor) 4-CP concentrations and almost complete toxicity removals were obtained. High biomass concentrations obtained at HRT levels above 15 h were due to low 4-CP contents in the aeration tank yielding negligible inhibition effects and low maintenance requirements. The sludge volume index (SVI) decreased with increasing HRT up to 15 h due to high biomass concentrations at high HRT levels resulting in well settling sludge with low SVI values. Hydraulic residence times above 15 h resulted in more than 90% COD and complete 4-CP and toxicity removals along with well settling sludge.  相似文献   

4.
Resting (living) bio-sludge from a domestic wastewater treatment plant was used as an adsorbent of both direct dyes and organic matter in a sequencing batch reactor (SBR) system. The dye adsorption capacity of the bio-sludge was not increased by acclimatization with direct dyes. The adsorption of Direct Red 23 and Direct Blue 201 onto the bio-sludge was almost the same. The resting bio-sludge showed higher adsorption capacity than the autoclaved bio-sludge. The resting bio-sludge that was acclimatized with synthetic textile wastewater (STWW) without direct dyes showed the highest Direct Blue 201, COD, and BOD(5) removal capacities of 16.1+/-0.4, 453+/-7, and 293+/-9 mg/g of bio-sludge, respectively. After reuse, the dye adsorption ability of deteriorated bio-sludge was recovered by washing with 0.1% sodium dodecyl sulfate (SDS) solution. The direct dyes in the STWW were also easily removed by a GAC-SBR system. The dye removal efficiencies were higher than 80%, even when the system was operated under a high organic loading of 0.36kgBOD(5)/m(3)-d. The GAC-SBR system, however, showed a low direct dye removal efficiency of only 57+/-2.1% with raw textile wastewater (TWW) even though the system was operated with an organic loading of only 0.083kgBOD(5)/m(3)-d. The dyes, COD, BOD(5), and total kjeldalh nitrogen removal efficiencies increased up to 76.0+/-2.8%, 86.2+/-0.5%, 84.2+/-0.7%, and 68.2+/-2.1%, respectively, when 0.89 g/L glucose (organic loading of 0.17kgBOD(5)/m(3)-d) was supplemented into the TWW.  相似文献   

5.
A pre-denitrification activated sludge system (AS) without internal recycle was used in lab-scale studies of landfill leachate treatment. A bentonite supplement at a ratio of 1:4 (mineral : biomass) was used to ensure high sludge settling levels and to serve as a micro-organisms carrier. The system was operated within different parameters such as hydraulic retention time (HRT), ammonia loading rate (ALR) or external recycle ratio, which was adapted to treat varying leachate concentrations of COD and ammonia, ranging from 1020 to 2680 mgO(2)l(-1) and 400-890 mgNH(4)-Nl(-1) respectively. The nitrification was complete and ammonia oxidation reached 99%; this was obtained while the ALR did not exceed 0.09 g NH(4)(+)-Ng(-1)MLVSS d(-1) and HRT was not lower than 1 day (in the aeration reactor). The performance of denitrification was successfully improved by controlling the external recycle rate, when the BOD(5)/N ratio in the raw leachate was 4.1. Consequently, N-removal of up to 80% was achieved. A 10-fold decrease in the denitrification rate was obtained at a BOD(5)/N ratio of 0.5. The efficiency of COD removal varied significantly from 36% to 84%. The positive effect of bentonite addition was determined and is discussed based on preliminary studies. The experiments were carried out in fill-and-draw activated sludge with bentonite; the biomass ratio was 1:2. The activated sludge with bentonite was fed with a synthetic high ammonia and organic-free medium.  相似文献   

6.
Chlorophenol compounds present in many chemical industry wastewaters are resistant to biological degradation because of the toxic effects of such compounds on microorganisms. Synthetic wastewater containing different concentrations of 2,4 dichlorophenol (DCP) was subjected to biological treatment in an activated sludge unit. Effects of feed DCP concentration on COD, DCP, and toxicity removals and on sludge volume index were investigated at a constant sludge age of 10 days and hydraulic residence time (HRT) of 25 h. The Resazurin method based on dehydrogenase activity was used for assessment of toxicity for the feed and effluent wastewater. Percent COD, DCP, and toxicity removals decreased and the effluent COD, DCP, and toxicity levels increased with increasing feed DCP concentrations above 150 mgl(-1) because of inhibitory effects of DCP. Biomass concentration in the aeration tank decreased and the sludge volume index (SVI) increased with feed DCP concentrations above 150 mgl(-1) resulting in lower COD and DCP removal rates. The system should be operated at feed DCP concentrations of less than 150 mgl(-1) in order to obtain high COD, DCP, and toxicity removals.  相似文献   

7.
Constructed wetlands (CW) usually require large land areas for treating wastewater. This study evaluated the feasibility of applying CW with less land requirement by operating a group of microcosm wetlands at a hydraulic retention time (HRT) of less than 4 d in southern Taiwan. An artificial wastewater, simulating municipal wastewater containing 200 mg L(-1) of chemical oxygen demand (COD), 20 mg L(-1) of NH4+-N (AN), and 20 mg L(-1) of PO4(3-)-P (OP), was the inflow source. Three emergent plants [reed, Phragmites australis (Cav.) Trin. ex Steud.; water primrose, Ludwigia octovalvis (Jacq.) P.H. Raven; and dayflower, Commelina communis L.] and two floating plants [water spinach, Ipomoea aquatica Forssk.; and water lettuce, Pistia stratiotes L.] plants were tested. The planted systems showed more nutrient removal than unplanted systems; however, the type of macrophytes in CW did not make a major difference in treatment. At the HRTs of 2 to 4 d, the planted system maintained greater than 72,80, and 46% removal for COD, AN, and OP, respectively. For AN and OP removal, the highest efficiencies occurred at the HRT of 3 d, whereas maximum removal rates for AN and OP occurred at the HRT of 2 d. Both removal rates and efficiencies were reduced drastically at the HRT of 1 d. Removals of COD, OP, and AN followed first-order reactions within the HRTs of 1 to 4 d. The efficient removals of these constituents obtained with HRT between 2 and 4 d indicated the possibility of using a CW system for wastewater treatment with less land requirement.  相似文献   

8.
为了解决污水厂生化系统剩余污泥产量过多的问题,采用延长污泥龄(SRT)的方法,对剩余污泥减量化的影响进行了研究。实验得知:污泥龄由8d增至16d时,污泥表观产率系数下降28.53%,而污泥龄由8d增至24d时,污泥表观产率系数下降51.12%。污泥龄的延长对CODCr的去除能力没有明显的影响,但使出水NH3-N浓度和TP浓度均升高,通过调整碳氮磷源的比例降低出水NH3-N和TP浓度。实验结果表明:SRT的延长,不仅降低活性污泥工艺中的剩余污泥的产量,同时还能降低处理与处置的费用,有发展前景,值得深入研究。  相似文献   

9.
A laboratory continuous feed biofilm reactor, comprising a bulk fluid reactor, a biofilm plastic module, a feed tank, and pneumatic devices and controls, was operated for a total period of 257 days, including seeding time, to treat domestic-strength synthetic wastewater under increasing ammonium nitrogen (NH(4)(+)--N) loading rates, ranging from 0.17+/-0.01 (0.71+/-0.06 gm(-2)d(-1)) to 0.70+/-0.02 kgm(-3)d(-1) (2.9+/-0.1 gm(-2)d(-1)). The biofilm plastic module was moved vertically in and out of the wastewater in continuous cycles. The maximum NH(4)(+)-N removal rate was reached during the maximum loading phase, when a NH(4)(+)--N loading rate of 0.70+/-0.02 kgm(-3)d(-1) (2.9+/-0.1 gm(-2)d(-1)) was applied to the system. During this loading period, the average NH(4)(+)--N removal rate was 0.30+/-0.10 kgm(-3)d(-1) (1.30+/-0.40 gm(-2)d(-1)).  相似文献   

10.
Due to the toxic effects of trichlorophenol (TCP) on microorganisms, biological treatment efficiencies of TCP containing wastewaters are usually low. Synthetic wastewater containing 2,4,6-TCP was biologically treated in a hybrid-loop bioreactor system consisting of a packed column biofilm and an aerated tank bioreactor with effluent recycle in order to improve COD and TCP removals. Effects of the feed TCP concentration on COD, TCP and toxicity removal performance of the system were investigated for the feed TCP between 50 and 450 mg L(-1) while the sludge age (solids retention time, SRT) and hydraulic residence time (HRT) were kept constant at 20 d and 25 h, respectively. Biomass concentrations in the packed column and in the aeration tank decreased with increasing feed TCP concentrations due to toxic effects of TCP on the organisms. Low biomass concentrations in the system at high feed TCP contents resulted in low COD, TCP and toxicity removals. Therefore, percent TCP, COD and toxicity removals decreased with increasing feed TCP concentrations especially above 400 mg L(-1). The effluent TCP concentrations were lower than 20 mg L(-1) for the feed TCP concentrations below 390 mg L(-1) resulting in TCP and COD removals above 90%. Specific rates of TCP and COD removals increased with the feed TCP due to low biomass concentrations at high TCP contents. The system should be operated at a feed TCP lower than 400 mg L(-1) in order to obtain more than 90% TCP, COD and toxicity removals under the specified experimental conditions.  相似文献   

11.
The present study focuses on a two-step process for treatment and stabilisation of primary sludge. The process consists of a hyper-thermophilic hydrolysis step operated at 70 degrees C and a hydraulic retention time (HRT) of 2 days followed by a thermophilic (55 degrees C) anaerobic digestion step at a HRT of 13 days. A one-step anaerobic digester operated at 55 degrees C and 15 days HRT was used as a reference process. The two-step process was characterized by a 12% higher organic suspended solids removal efficiency and better pathogen reduction effect than the conventional one-step digestion. The microbial community of the digester fed with pre-treated sludge was characterised by a higher activity compared to that of the digester treating raw sludge. Moreover, the pre-treatment of the primary sludge resulted up to 48% increase of the methane potential (20.09 and 13.56mmolCH(4)g(-)VS(-1) with and without pre-treatment, respectively) and up to 115% increase of the methane production rate. Finally it was shown that the extra energy requirements for the operation of a pre-treatment step would be covered by the energy produced from the extra methane production and in addition there would be a significant energy surplus of 2.17kJd(-1) for the system tested.  相似文献   

12.
MBR工艺处理粮油加工废水的研究   总被引:2,自引:0,他引:2  
金波  李宝新  位红卫 《四川环境》2010,29(3):24-27,31
采用MBR(Membrane Bioreactor)工艺对粮油加工废水进行处理发现,污染物的去除是活性污泥和膜截留共同作用的结果,试验中微生物的去除作用占污染物总去除率的62.9%~88.1%,起主要作用。当系统的污泥负荷和容积负荷分别在0.4~0.54 kgCOD/kgMLSS.d之间和3.8~5.0 kgCOD/m3.d之间变化时,系统对COD的去除率在92.5%以上。本试验所用膜的临界膜通量为8~10 L/(m2.h),系统污泥浓度从1~2g/L增加到10~12g/L时,临界膜通量从10~12L/(m2.h)下降到了3~4 L/(m2.h),随着膜面流速从1.0m/s上升到1.8m/s,膜的临界通量也相应的从4~6 L/(m2.h)上升到了16~18 L/(m2.h),呈正相关。  相似文献   

13.
Ammonia (NH3) removal efficencies were evaluated when hydrogen sulfide (H2S) and NH3 in binary mixture gases were supplied to a ceramic biofilter seeded with earthworm (Lumbricus terrestris) casts. The effect of inlet H2S concentration and space velocity (SV) on the removal of NH3 was investigated after the acclimation of the biofilter with NH3 gas. When NH3 was singly supplied to the biofilter, NH3 removal was maintained at almost 100% until inlet NH3 concentration was increased up to 600 microL L(-1) and SV up to 330 h(-1), at which the elimination capacity of NH3 was 148 g N m(-3) h(-1). When H2S was supplied simultaneously, however, the accumulation of toxic sulfide ions showed dual effects on NH3 removal efficiencies. First, no effects were observed at inlet H2S loading below 60 g S m(-3) h(-1); however, inhibition by H2S at higher loading was observed above 60 g S m(-3) h(-1). The point at which loading achieved a maximum of more than 99% NH3 removal efficiency was 139 g N m(-3) h(-1), when inlet H2S concentration was held under 100 microL L(-1), but it dropped to 76 and 30 g N m(-3) h(-1) when the inlet H2S concentration increased to 220 and 460 microL L(-1), respectively. The critical points of inlet H2S loading that guaranteed over 99% NH3 removal were determined as 100, 100, 60, and 40 g S m(-3) h(-1) at inlet NH3 concentrations of 100, 200, 400, and 600 microL L(-1), respectively. Inlet NH3 loading had synergic effects of increasing the inhibition of inlet H2S loading on the NH3 removability of the biofilter.  相似文献   

14.
In order to improve the process performance regarding the removal of organics, nitrogen, and an odor-causing compound (sulfide) contained in domestic wastewater, an entrapped-mixed-microbial cell (EMMC) with and without humic substances for both fixed and moving carrier reactors and conventional suspended growth culture (i.e. conventional activated sludge process) were investigated simultaneously. Both synthetic (simulated to the organics concentration of general domestic sewage) and actual domestic wastewater were investigated under operational conditions of 12 h of hydraulic retention time (HRT) with 1 h of aeration and 1 h of non-aeration, and 6 h of HRT with continuous aeration, at a room temperature of 25 +/- 2 degrees C. It was found that entrapping humic substances in the EMMC carriers had no impact on the removal of organics, nitrogen, and the odor-producing compound. Additionally, the performance of the EMMC moving carrier system for the removal of these pollutants is similar to that of the EMMC fixed carrier system. In general, the EMMC associated systems which provide high solids retention time achieve a better removal of chemical oxygen demand (COD), nitrogen, and the odor-producing substance than the suspended growth system for both HRTs of 6 h (continuous aeration) and 12 h (1 h of aeration and 1 h of non-aeration). Both the fixed and moving carrier EMMC processes, therefore, have the potential for improvement or replacement of the existing conventional activated sludge process with regard to improving the effluent qualities (such as COD, nitrogen and odor-producing compound) for reuse/disposal.  相似文献   

15.
The effect of using ground tire rubber (GTR) as an adsorptive material in the removal of a 2:1:1 weight mixture of n-butyl acetate, toluene and m-xylene by using a peat biofilter under different intermittent conditions was investigated. The performance of two identical size biofilters, one packed with fibrous peat alone and the other with a 3:1 (vol) fibrous peat and GTR mixture, was examined for a period of four months. Partition coefficients of both materials were measured. Values of 53, 118 and 402 L kg(-1) were determined for n-butyl acetate, toluene and m-xylene in peat, respectively; and values of 40, 609 and 3035 L kg(-1) were measured for the same compounds in GTR. Intermittent load feeding of 16 h per day, 5 days per week working at an EBRT of 60 s and an inlet VOC concentration of 0.3 g C m(-1), resulted in removal efficiencies higher than 90% for both biofilters, indicating that the addition of GTR did not adversely affect the behavior of the bioreactor. Full removal of n-butyl acetate was obtained for both biofilters. GTR improved the removal of the aromatics in the first part of the biofilter, facilitating lower penetration of the toluene and m-xylene into the bed. A 31-day starvation period was applied and intermittent operation subsequently restarted. In both biofilters, high removal efficiencies after a re-acclimation period of two days were achieved. A shock loading test related to 1-h peaks of three- and four-fold increases in its baseline concentration (0.30 g C m(-3)) was applied in both biofilters. For the biofilter packed with the peat and GTR mixture, attenuation greater than 60% was observed in the maximum outlet concentration when compared to the biofilter packed with peat alone.  相似文献   

16.
In Ireland, no database detailing the design, influent loading rates or performance of constructed wetlands (CWs) exists. On account of this, they are designed without any protocol based on empirical data. The aim of this paper was to provide the first published data on the performance of free-water surface flow (FWSF) CWs treating primary and secondary-treated municipal wastewater, and agricultural dairy soiled water (DSW) in Ireland. In total, the performance of thirty-four FWSF CWs, comprising fourteen CWs treating primary-treated municipal wastewater, thirteen CWs treating secondary-treated municipal wastewater, and seven CWs treating DSW, were examined. In most CWs, good organic, suspended solids (SS) and nutrient removal was measured. At an average organic loading rate (OLR) of 10 and 9 g biochemical oxygen demand (BOD) m(-2) d(-1), CWs treating primary and secondary wastewater removed 95 and 84% of influent BOD. Constructed wetlands treating DSW had an average BOD removal of 98%. At average SS loading rates of 6 and 14 g m(-2) d(-1), CWs treating primary and secondary wastewater had a 96 and an 82% reduction, and produced a final effluent with a concentration of 14 and 13 mg L(-1). Constructed wetlands treating DSW produced a final effluent of 34 mg L(-1) (94% reduction). Similar to other studies, all CWs examined had variable performance in ammonium-N (NH(4)(+)-N) removal, with average removals varying between 37% (for CWs treating secondary wastewater) and 88% (for CWs treating DSW). Variable ortho-phosphorus (PO(4)(3-)-P) removal was attributable to different durations of operation, media types and loading rates.  相似文献   

17.
A stratified sand filter column, operated in recirculation mode and treating synthetic effluent resembling high-strength dairy wastewaters was studied over a 342-d duration. The aim of this paper was to examine the organic, total suspended solids (TSS) and nutrient removal rates of the sand filter, operated in recirculation mode, under incrementally increasing hydraulic and organic loading rates and to propose a field filter-sizing criterion. Best performance was obtained at a system hydraulic loading rate of 10 L m(-2) d(-1); a higher system hydraulic loading rate (of 13.4 L m(-2) d(-1)) caused surface ponding. The system hydraulic loading rate of 10 L m(-2) d(-1) gave a filter chemical oxygen demand (COD), TSS, and total kjeldahl nitrogen (TKN) loading rate of 14, 3.7, and 2.1 g m(-2) d(-1), respectively, and produced consistent COD and TSS removals of greater than 99%, and an effluent NO(3)-N concentration of 42 mg L(-1) (accounting for an 86% reduction in total nitrogen (Tot-N)). As the proportional surface area requirement for the sand filter described in this study is less than the recommended surface area requirement of a free-water surface (FWS) wetland treating an effluent of similar quality, it could provide an economic and sustainable alternative to conventional wetland treatment.  相似文献   

18.
This paper addresses the treatment of purified terephthalic acid (PTA) effluent using anaerobic and aerobic processes. Laboratory studies were carried out on flow proportionate composite wastewater generated from the manufacturing of PTA. An activated sludge process (ASP-two stage and single stage) and an upflow anaerobic fixed film fixed bed reactor (AFFFBR) were used, individually and in combination. The performance of a full-scale ETP under existing operating conditions was also studied. Full scale ETP studies revealed that the treatment of PTA effluent using a two-stage ASP alone does not meet treated effluent quality within the prescribed Indian Standards. The biomass produced in the two stage ASP was very viscous and fluffy and the sludge volume index (SVI) was very high (200-450 ml/g). However, pretreatment of PTA effluent using an upflow AFFFBR ensured substantial reduction in BOD (63%) and COD (62%) with recovery of biogas at 1.8-1.96 l/l effluent treated at a volumetric loading rate (VLR) 4-5 kg COD/m(3) d. The methane content in the biogas varied between 55% and 60%. The pretreated effluent from the upflow AFFFBR was then treated through a single stage ASP. The biomass produced in the ASP after anaerobic treatment had very good settlability (SVI: 75-90 ml/g) as compared to the two stage ASP and the treated effluent quality with respect to BOD, COD and SS was within the prescribed Indian Standards. The alternative treatment process comprising an upflow AFFFBR and a single stage ASP ensured net power saving of 257 kW and in addition generated 442 kW of power through the AFFFBR.  相似文献   

19.
In Ireland, dairy farmyard washwater commonly comprises farmyard run-off and dairy parlour washings. Land-spreading is the most widely used method for treating this wastewater. However, this method can be labour intensive and can cause, in some cases, the degradation of surface and ground waters, mainly due to nitrogen contamination. In this study, a horizontal flow biofilm reactor (HFBR) with step-feed was constructed and tested in the laboratory, to remove organic carbon and nitrogen from a agricultural strength synthetic washwater (SWW). The HFBR had an average top plan surface area (TPSA) of 0.1002 m(2) and consisted of a stack of 45 polystyrene horizontal sheets--15 sheets embedded with 25 mm deep frustums above 30 sheets with 10 mm deep frustums. The frustums acted as miniature reservoirs. The sheets were alternately offset to allow the wastewater to flow horizontally along each sheet and vertically from sheet to sheet down through the reactor. Biofilms developed on the sheets and treated the wastewater. During the 212-d study, the total hydraulic loading rate based on the TPSA of the sheets was 35 l m(-2) d(-1). SWW was pumped for 10 min each hour, in a step feed arrangement at a rate of 23.33 l m(-2) d(-1) on to the top sheet during Phases 1 and 2, and 11.67 l m(-2) d(-1) onto Sheet 16 during Phase 1 (days 1-92) and onto Sheet 30 during Phase 2 (days 93-212). The substrate loading rate during Phases 1 and 2 was 94.8 g total chemical oxygen demand (COD) m(-2) d(-1) and 10.5 g total nitrogen (TN) m(-2) d(-1), based on the TPSA. At steady state in Phase 2, the unit achieved excellent carbon removal of 99.7% 5-day biochemical oxygen demand (BOD(5)) and 96.7% total COD, equivalent to TPSA removal rates of 67.5 g BOD(5)m(-2)d(-1) and 91.7 g COD m(-2) d(-1). The nitrogen removal percentages were 98.3% total ammonium-nitrogen (NH(4)-N(t)) and 72.8% TN, which equated to TPSA removal rates of 4.8 g NH(4)-N(t) m(-2) d(-1) and 7.6g TN m(-2) d(-1). No sloughing of solids or clogging of media occurred during the study. The unit was simple to construct and operate, with little maintenance.  相似文献   

20.
The effect of organic loading on the performance of a mechanically stirred anaerobic sequencing biofilm batch reactor (ASBBR) has been investigated, by varying influent concentration and cycle period. For microbial immobilization 1-cm polyurethane foam cubes were used. An agitation rate of 500 rpm and temperature of 30+/-2 degrees C were employed. Organic loading rates (OLR) of 1.5-6.0gCODl(-1)d(-1) were applied to the 6.3-l reactor treating 2.0 l synthetic wastewater in 8 and 12-h batches and at concentrations of 500-2000mgCODl(-1), making it possible to analyze the effect of these two operation variables for the same organic loading range. Microbial immobilization on inert support maintained approximately 60 gTVS in the reactor. Filtered sample organic COD removal efficiencies ranged from 73 to 88% for organic loading up to 5.4gCODl(-1)d(-1). For higher organic loading (influent concentration of 2000mgCODl(-1) and 8-h cycle) the system presented total volatile acids accumulation, which reduced organics removal efficiency down to 55%. In this way, ASBBR with immobilized biomass was shown to be efficient for organic removal at organic loading rates of up to 5.4gCODl(-1)d(-1) and to be more stable to organic loading variations for 12-h cycles. This reactor might be an alternative to intermittent systems as it possesses greater operational flexibility. It might also be an alternative to batch systems suspended with microorganisms since it eliminates both the uncertainties regarding granulation and the time necessary for biomass sedimentation, hence reducing the total cycle period.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号