首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 890 毫秒
1.
All odor measurement methods may be conveniently grouped into three categories: (1) threshold; (2) suprathreshold; and (3) analytical. The threshold techniques include such methods as syringe dilution, scentometer, and osmoscope. Suprathreshold techniques include direct comparison methods and dilution methods involving subjective ratings of preference as opposed to intensity. Analytical techniques involve the use of physicochemrcal methods, e.g., for monitoring of process streams or identification of individual odorants. The relative advantages and disadvantages of each method, as presently used, are discussed. Recommended applications for the various methods and suggested modifications are also presented.  相似文献   

2.
Atmospheric samples collected in several American cities were analyzed for SO2 concentration using various analytical methods. The methods were: (1) electroconductivity, (2) West-Gaeke, (3) West-Gaeke with membrane prefdter, (4) West-Gaeke with glass-fiber prefilter, (5) hydrogen peroxide, (6) hydrogen peroxide with membrane prefilter, and (7) hydrogen peroxide with glass-fiber prefilter. The relationships among SO2 data produced by these methods were evaluated statistically. Where statistical differences among methods, at the 95% confidence level, were determined then relationships were further delineated. Factors considered in these comparisons were: (1) location, {2) time of day, (8) concentration range, (4) particulate concentration, and (5) humidity. Laboratory evaluations of these methods show that each method is subject to different interfering substances. Laboratory evaluations of these methods show that each method is subject to different interfering substances. The relationship among methods obtained in these studies will complement these data and perhaps provide for further laboratory and field evaluation of methods used to measure SO2. The relationship among SO2 data produced by these methods should be useful in relating atmospheric SO2 concentration to its effects and to those involved in establishing ambient air quality standards.  相似文献   

3.
综述了近几年来炼焦废水及炼焦废水中主要成分(酚类、氨类物质、氰化物)的生化处理方法.其中废水中酚类物质的去除方法有投加有效菌、超滤法等;去除氨类物质的方法有A2/O法、纳滤法和反渗透法等;去除氰化物的方法有生物法和化学法等.综合处理炼焦废水的方法有双层生物膜法、生物脱氮法和含铁活性污泥处理技术等.  相似文献   

4.
The effect of different DNA extraction protocols on activated sludge DNA yield and bacterial community composition was evaluated by temperature gradient gel electrophoresis (TGGE). Nine different procedures to extract DNA were compared-sonication (30s), sonication (40s), sonication (50s), freezing-thawing, bead milling, sodium dodecyl sulfate (SDS)-lysozyme, SDS-proteinase K, SDS-lysozyme-proteinase, and a commercial extraction kit. It was found that the TGGE profiles and the DNA band numbers made significant differences via various extraction methods. The yield and purity of DNA extracted by sonication and other physical methods were not satisfactory, while the DNA purity extracted by SDS and other chemical-biological methods were better. Crude DNA extracts isolated by sonication and other physical methods passed the polymerase chain reaction, despite the absence of purification and acquired affluent DNA bands in TGGE. The affluence of bands in TGGE was not consistent with the yield and purification of DNA, but was correlative with extraction protocols. To analyze the activated sludge bacterial community by TGGE fingerprint, it is necessary to make a synthesis of the TGGE fingerprint profiles of chemical and physical DNA extraction methods to overcome the representative bias.  相似文献   

5.
Abstract

Three new methods applicable to the determination of hazardous metal concentrations in stationary source emissions were developed and evaluated for use in U.S. Environmental Protection Agency (EPA) compliance applications. Two of the three independent methods, a continuous emissions monitor-based method (Xact) and an X-ray-based filter method (XFM), are used to measure metal emissions. The third method involves a quantitative aerosol generator (QAG), which produces a reference aerosol used to evaluate the measurement methods. A modification of EPA Method 301 was used to validate the three methods for As, Cd, Cr, Pb, and Hg, representing three hazardous waste combustor Maximum Achievable Control Technology (MACT) metal categories (low volatile, semivolatile, and volatile). The modified procedure tested the methods using more stringent criteria than EPA Method 301; these criteria included accuracy, precision, and linearity. The aerosol generation method was evaluated in the laboratory by comparing actual with theoretical aerosol concentrations. The measurement methods were evaluated at a hazardous waste combustor (HWC) by comparing measured with reference aerosol concentrations. The QAG, Xact, and XFM met the modified Method 301 validation criteria. All three of the methods demonstrated precisions and accuracies on the order of 5%. In addition, correlation coefficients for each method were on the order of 0.99, confirming the methods’ linear response and high precision over a wide range of concentrations. The measurement methods should be applicable to emissions from a wide range of sources, and the reference aerosol generator should be applicable to additional analytes. EPA recently approved an alternative monitoring petition for an HWC at Eli Lilly’s Tippecanoe site in Lafayette, IN, in which the Xact is used for demonstrating compliance with the HWC MACT metal emissions (low volatile, semivolatile, and volatile). The QAG reference aerosol generator was approved as a method for providing a quantitative reference aerosol, which is required for certification and continuing quality assurance of the Xact.  相似文献   

6.
Three new methods applicable to the determination of hazardous metal concentrations in stationary source emissions were developed and evaluated for use in U.S. Environmental Protection Agency (EPA) compliance applications. Two of the three independent methods, a continuous emissions monitor-based method (Xact) and an X-ray-based filter method (XFM), are used to measure metal emissions. The third method involves a quantitative aerosol generator (QAG), which produces a reference aerosol used to evaluate the measurement methods. A modification of EPA Method 301 was used to validate the three methods for As, Cd, Cr, Pb, and Hg, representing three hazardous waste combustor Maximum Achievable Control Technology (MACT) metal categories (low volatile, semivolatile, and volatile). The modified procedure tested the methods using more stringent criteria than EPA Method 301; these criteria included accuracy, precision, and linearity. The aerosol generation method was evaluated in the laboratory by comparing actual with theoretical aerosol concentrations. The measurement methods were evaluated at a hazardous waste combustor (HWC) by comparing measured with reference aerosol concentrations. The QAG, Xact, and XFM met the modified Method 301 validation criteria. All three of the methods demonstrated precisions and accuracies on the order of 5%. In addition, correlation coefficients for each method were on the order of 0.99, confirming the methods' linear response and high precision over a wide range of concentrations. The measurement methods should be applicable to emissions from a wide range of sources, and the reference aerosol generator should be applicable to additional analytes. EPA recently approved an alternative monitoring petition for an HWC at Eli Lilly's Tippecanoe site in Lafayette, IN, in which the Xact is used for demonstrating compliance with the HWC MACT metal emissions (low volatile, semivolatile, and volatile). The QAG reference aerosol generator was approved as a method for providing a quantitative reference aerosol, which is required for certification and continuing quality assurance of the Xact.  相似文献   

7.
Two approaches for identification of source locations and preferred transport pathways of atmospheric particulate trace elements and aerosol species are investigated, namely, versions of the potential source contribution function method (PSCF) and the concentration field method (CF). Both methods are based on combining chemical data with calculated air parcel backward trajectories. The two methods are applied to four multi-species multi-annual concentration time series measured at sites in Finland, Norway, and Israel. A non-parametric bootstrap technique is used to estimate the statistical significance of the calculated PSCF values. It is found that the methods agree well with each other and correctly identify known emission sources. Examples of applying the methods are presented, mainly for the site in Finland.  相似文献   

8.
Three methods for measuring gaseous ambient nitric acid in the low concentration range 0–15 μ m−3 were compared under field conditions in Southwestern Ontario during 1–14 June 1982. The methods employed were (1) tunable diode laser absorption, (2) a tungstic acid denuder tube and (3) a filter pack containing a Teflon-nylon-W41 filter combination operated over 3-h sampling periods. In general, the three methods measured nitric acid with adequate sensitivity (sub ppb) and they correlated reasonably over the low ambient concentrations considered here. However, there were some notable differences (up to a factor of 2 at night) by the tungstic acid and filter pack methods. During the field comparison, particulate nitrate and ammonium were also measured (0–6 μg m−3 range) by the tungstic acid and filter pack methods. These correlated well but some differences (less than 20%) were observed in the particulate nitrate measurements. In view of the low concentrations measured and the resultant larger experimental error, specific loss or interfering mechanisms could not be unambiguously identified.  相似文献   

9.
Solid phase microextraction (SPME) presents many advantages over conventional analytical methods by combining sampling, preconcentration, and direct transfer of the analytes into a standard gas chromatograph (GC). Since its commercial introduction in the early 1990s, SPME has been successfully applied to the sampling and analysis of environmental samples. This paper presents an overview of the current methods for air sampling and analysis with SPME using both grab and time-weighted average (TWA) modes. Methods include total volatile organic compounds (TVOCs), formaldehyde, and several target volatile organic compounds (VOCs). Field sampling data obtained with these methods in indoor air were validated with conventional methods based on sorbent tubes. The advantages and challenges associated with SPME for air sampling are also discussed. SPME is accurate, fast, sensitive, versatile, and cost-efficient, and could serve as a powerful alternative to conventional methods used by the research, industrial, regulatory, and academic communities.  相似文献   

10.
A comparison of the two most common methods used by air pollution control agencies for the analyses of sulfur dioxide is discussed in this paper. Samples were collected simultaneously (502 pairs) for an eight month period at eight sites in the City of Chicago, using the West-Gaeke and conductivity methods. These methods are analyzed statistically to ascertain the existence of a factor describing adequately any differences between methods.  相似文献   

11.
Analytical methods to improve the detection of erythromycin in water and sediment were developed to optimize for erythromycin's recovery of extractable and bound residues from the aquatic environment. The objective of this study was to determine optimal recovery of erythromycin from water and sediment to improve its detection in environmental samples through solid-phase extraction (SPE) and sediment-extraction methods. SPE methods examined included previously reported methods for macrolide and sulfonamide antibiotics with erythromycin recoveries ranging from 75.5 % to 94.7 %. Extraction of erythromycin was performed from sand employing various solvents and buffers to determine the best method for extraction from two sandy loam pond sediments. Various extraction times were also examined, and all extraction procedures were performed in duplicate. The greatest recovery of (14)C-erythromycin in the Iowa sediment was 84 % using 0.3 M ammonium acetate at pH 4.2: acetonitrile (15:85, v/v) solution. The Oklahoma sediment yielded the greatest recovery of (14)C-erythromycin at 86.7 % with 0.3 M ammonium acetate at pH 7: acetonitrile (30:70, v/v) with a 60-minute shake time. The present results demonstrate improved extraction methods for enhancing the accuracy of erythromycin detection from environmental samples.  相似文献   

12.
Results of an international ring-test of two laboratory methods are presented for investigating the biodegradability of organic polymeric test materials in aquatic test systems based on respirometry and the evolution of carbon dioxide. These methods are developed further from the well-known standardized biodegradation tests ISO 9408 (1999) and ISO 9439 (1999), which have been successfully used for many years. The most important improvements are the extension of the test period up to six months, the increase of the buffer capacity and nutrient supply of the inorganic medium, an optimization of the inoculation, and optionally, the possibility of a carbon balance. A ring test, organized by the International Biodeterioration Research Group (IBRG), was run using a poly(,-caprolactone)-starch blend and an aliphatic-aromatic co-polyester as test materials and a microcrystalline cellulose powder as a reference material. The test results and the experience gained by the participants showed that the methods are suitable and practicable. The test methods have been meanwhile established as standards ISO 14851 (1999) and ISO 14852 (1999).  相似文献   

13.
Species sensitivity distributions (SSDs) are increasingly used in both ecological risk assessment and derivation of water quality criteria. However, there has been debate about the choice of an appropriate approach for derivation of water quality criteria based on SSDs because the various methods can generate different values. The objective of this study was to compare the differences among various methods. Data sets of acute toxicities of 12 substances to aquatic organisms, representing a range of classes with different modes of action, were studied. Nine typical statistical approaches, including parametric and nonparametric methods, were used to construct SSDs for 12 chemicals. Water quality criteria, expressed as hazardous concentration for 5 % of species (HC5), were derived by use of several approaches. All approaches produced comparable results, and the data generated by the different approaches were significantly correlated. Variability among estimates of HC5 of all inclusive species decreased with increasing sample size, and variability was similar among the statistical methods applied. Of the statistical methods selected, the bootstrap method represented the best-fitting model for all chemicals, while log-triangle and Weibull were the best models among the parametric methods evaluated. The bootstrap method was the primary choice to derive water quality criteria when data points are sufficient (more than 20). If the available data are few, all other methods should be constructed, and that which best describes the distribution of the data was selected.  相似文献   

14.
Methods for assessing the quality of marine coastal environments are numerous and rapidly evolving. The integration of physiological parameters termed as Scope for Growth (SfG) and the luminescent bioassay Microtox were applied in several sites of Saronikos and Amvrakikos Gulfs (Greece) to assess the environmental quality and compare the results of the two methods. Each site in the two areas undergoes different types and levels of pollution. Both methods could identify a pollution gradient reflecting the quality of each site. A very good linear correlation was noticed between the two methods (r = 0.98). The stress order, which was similar in both methods, exhibited the expected pollution gradient according to the pressure that each site undergoes. Results suggest that for screening and fast isolation of polluted sites before further analysis, the rapid and simple Microtox assay could operate as an alternative to the more complex SfG method.  相似文献   

15.
Engineered nanoscale zero-valent metals (NZVMs) representing the forefront of technologies have been considered as promising materials for environmental remediation and antimicrobial effect, due to their high reducibility and strong adsorption capability. This review is focused on the methodology for synthesis of bare NZVMs, supported NZVMs, modified NZVMs, and bimetallic systems with both traditional and green methods. Recent studies have demonstrated that self-assembly methods can play an important role for obtaining ordered, controllable, and tunable NZVMs. In addition to common characterization methods, the state-of-the-art methods have been developed to obtain the properties of NZVMs (e.g., granularity, size distribution, specific surface area, shape, crystal form, and chemical bond) with the resolution down to subnanometer scale. These methods include spherical aberration corrected scanning transmission electron microscopy (Cs-corrected STEM), electron energy-loss spectroscopy (EELS), and near edge X-ray absorption fine structure (NEXAFS). A growing body of experimental data has proven that nanoscale zero-valent iron (NZVI) is highly effective and versatile. This article discusses the applications of NZVMs to treatment of heavy metals, halogenated organic compounds, polycyclic aromatic hydrocarbons, nutrients, radioelements, and microorganisms, using both ex situ and in situ methods. Furthermore, this paper briefly describes the ecotoxicological effects for NZVMs and the research prospects related to their synthesis, modification, characterization, and applications.  相似文献   

16.
Comparison of four methods including liquid-liquid extraction (LLE), direct aqueous injection (DAI), purge and trap (PAT) and head space (HS) were carried out in this work for determination of volatile organic compounds (VOCs) including trihalomethanes (THMs) in drinking water. This comparison is made especially to show the advantages and disadvantages and specifically the different detection limits (DL) that can be obtained for a given type of analysis. LLE is applicable only for determination of the THMs concentrations, while DAI, PAT, HS methods with different DL each of them are applicable for all VOCs, with PAT to be the most sensitive. Sampling apparatus and procedure for all these methods except of PAT are very simple and easy, but possible disadvantages for LLE and DAI are the low sensitivity and especially the detection only of THMs with LLE.  相似文献   

17.
空气中挥发性有机物监测技术的研究进展   总被引:13,自引:0,他引:13  
讨论了空气中挥发性有机化合物(VOCs)的监测分析方法研究进展。重点介绍了空气中VOCs的采集、分析和测定;简要叙述了样品前处理的新方法--固相微萃取法(SPME)与其它前处理方法的研究概况。  相似文献   

18.
In order to comply with the ammonia (NH(3)) emission reduction assigned to the Netherlands development of new measures are needed, which should be supported by fast and accurate measurements to arrive at new estimates of the NH(3) emission from each agricultural source. This paper gives an overview of the current methods used in the Netherlands to measure NH(3) emissions from animal houses, and provides alternative methods for some particular situations. For mechanically ventilated animal houses, passive flux samplers placed in the ventilation shafts of the animal house are presented as alternative to measure a larger number of animal houses (replicates) with the same housing system at a low price. For naturally ventilated animal houses, when mixing in the animal house is not good enough to allow measurements within the animal house (internal tracer gas ratio method), two measurement methods are discussed: the Gaussian plume dispersion model, which is usually not suitable for agricultural situations, and the flux frame method, which is not always applicable because of distortion of the flow around the building. Finally, for animal houses with outside yards for the animals, there are at this moment no methods available to measure the NH(3) emissions from these complex situations, although quick box methods (for the outside yards) and a combination of a backward Lagrangian stochastic model with open-path concentration measurements with a tunable diode laser (TDL), look promising.  相似文献   

19.
In environmental monitoring, variables with analytically non-detected values are commonly encountered. For the statistical evaluation of these data, most of the methods that produce a less biased performance require specific computer programs. In this paper, a statistical method based on the median semi-variance (SemiV) is proposed to estimate the position and spread statistics in a dataset with single left-censoring. The performances of the SemiV method and 12 other statistical methods are evaluated using real and complete datasets. The performances of all the methods are influenced by the percentage of censored data. In general, the simple substitution and deletion methods showed biased performance, with exceptions for L/2, Inter and L/√2 methods that can be used with caution under specific conditions. In general, the SemiV method and other parametric methods showed similar performances and were less biased than other methods. The SemiV method is a simple and accurate procedure that can be used in the analysis of datasets with less than 50% of left-censored data.  相似文献   

20.
Analytical methods to improve the detection of erythromycin in water and sediment were developed to optimize for erythromycin's recovery of extractable and bound residues from the aquatic environment. The objective of this study was to determine optimal recovery of erythromycin from water and sediment to improve its detection in environmental samples through solid-phase extraction (SPE) and sediment-extraction methods. SPE methods examined included previously reported methods for macrolide and sulfonamide antibiotics with erythromycin recoveries ranging from 75.5 % to 94.7 %. Extraction of erythromycin was performed from sand employing various solvents and buffers to determine the best method for extraction from two sandy loam pond sediments. Various extraction times were also examined, and all extraction procedures were performed in duplicate. The greatest recovery of 14C-erythromycin in the Iowa sediment was 84 % using 0.3 M ammonium acetate at pH 4.2: acetonitrile (15:85, v/v) solution. The Oklahoma sediment yielded the greatest recovery of 14C-erythromycin at 86.7 % with 0.3 M ammonium acetate at pH 7: acetonitrile (30:70, v/v) with a 60-minute shake time. The present results demonstrate improved extraction methods for enhancing the accuracy of erythromycin detection from environmental samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号