首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Assessment of environmental and occupational exposure to chemicals can be performed with environmental monitoring (EM) and biological monitoring (BM). Biological monitoring was for a long time considered as a method complementary to environmental monitoring. At present this attitude is changing and in certain areas biological monitoring is applied as the method of choice for exposure and health-risk assessment. This paper examines advantages and disadvantages of those two approaches. In occupational settings environmental monitoring of exposure to VOCs seems to be superior to biological monitoring (possibility of simultaneous determination of components of mixtures, simple interpretation, possibility of evaluation of short-term exposure to local irritants). In the case of this group of compounds BM can be useful in selected cases such as evaluation of dermal absorption or efficiency of protective measures. In the case of metals both forms of monitoring can be used depending on the available methods for interpretation of results. BM of exposure may be considered as superior for evaluating the effects of exposure to lead, cadmium and mercury. However, quantitative evaluation of cancer risk after exposure to arsenic or chromium is possible only on the basis of determination in the air and the use of unit risk values. Both environmental and biological monitoring are useful for evaluation of occupational and environmental exposure to polycyclic aromatic hydrocarbons (PAHs). In certain areas such as evaluation of exposure to external tobacco smoking, cytostatic drugs, and pesticides, biological monitoring is the method of choice used for individual exposure assessment or tracing the trends of environmental exposure.  相似文献   

2.
进口与国产COD消解测定仪测定废水COD的比对研究   总被引:1,自引:0,他引:1  
应用消解分光光度法,比对了一款进口仪器和一款国产仪器应用于实际水样中COD含量测定的差异性。通过精密度、回收率、方法比对等实验分析得出,2款仪器应用电热消解分光光度法测定COD,实验结果与国标回流滴定法的实验结果基本一致,无显著性差异,具有可比性,可广泛用于水质评价和环境监测。与国产仪器相比,进口测定仪具有较小的偏差,较高的回收率。国产测定仪偏差较大的原因主要在于其比色装置,而不是用于前处理的消解装置。比较分析了2款仪器的购买和使用经济成本,为广大企事业及科研单位选用COD消解测定仪提供了有价值的基础数据和参考建议。  相似文献   

3.
介绍了一种基于厚膜传感器技术,可同时测量NO2、O3、CO三个因子的空气质量监测仪器。深入研究了仪器的检测原理,并对仪器的质量保证及数据存储传输进行了详细介绍。最后对仪器的检测性能进行了对比分析,通过和常规点式仪器的对比表明,该仪器NO2、O3、CO三因子的检测性能能够满足实际监测要求。另外,该仪器还具有集成性好、安装调试方便等特点,因此,在道路交通监测等领域中有广泛的应用前景。  相似文献   

4.
在中国,快速有效的环境监测执法需求越来越急迫,特别是在出现疫情与地质灾害等特殊时期,便携式快速监测仪器能更好地保证执法的时效性,但应用上却在执法环节一直受到监测数据合法性及标准方法等问题的困扰。笔者首先采用关键词频统计法研究了便携式环境监测设备相关领域的研究热点,在此基础上基于执法机构实践,调研了解了中国现行常规环境监测仪器设备质控和认证流程,指出便携监测与常规流程不匹配之处,以空气和废气中颗粒物和SO_2监测为例系统梳理了方法标准、质控、论证等内容,分析论证便携式设备在环境执法中数据有效性的问题,并针对便携监测设备的型式批准、强检、监测方法和数据合法性认定等问题提出具体建议。  相似文献   

5.
构建科学、准确、有效的量值溯源体系是实验室质量管理的重要内容.在国家市场监督管理总局新发布的《实施强制管理的计量器具目录》中,涉及环境监测用途的类别大幅度减少.在此背景下,研究介绍了量值溯源中检定和校准的差异及适用范围,强调不应将检测作为量值溯源的方式.分类比较了国内现有具备量传能力的计量技术机构,对目前生态环境监测领...  相似文献   

6.
A user-friendly environmental monitoring system that collects real time data has been developed. Flash card memory logs exposure data from multiple sensors along with corresponding times and positions. Optional use of telemetry repeaters and a reference station allows central monitoring of data to assess exposure and to initiate intervention when safe levels are exceeded. A software analysis package allows researchers to identify exposure hot spots and direct control efforts, with the ultimate goal being to reduce injury and disease. Preliminary field test results document position accuracy and system performance in harsh environments.  相似文献   

7.
为了掌握省辖市2003年以来空气自动监测系统的运行情况,根据几年的巡检,发现了一些影响空气自动监测系统运行的因素。本文主要从仪器、标准物质的使用、人员以及影响空气质量日报结果等几个方面进行了阐述,并提出了相应的改进措施,以期能对空气自动监测系统的管理提供借鉴。  相似文献   

8.
对我国环境自动监测发展的思考   总被引:29,自引:16,他引:13  
阐述了我国环境自动监测的现状,指出环境自动监测的发展势头迅猛异常,国产自动监测仪器设备的发展前景广阔,而仪器设备标准化和监测系统规范化问题比较突出,建议自动监测系统的建设发展速度适度控制,重视自动监测信息建设与数据共享问题,加强监控管理,理顺管理体制和运行机制.  相似文献   

9.
为考核辐射环境监测质量,浙江省辐射环境监测站组织了2010年全省辐射环境监测网络环境电磁辐射测量比对。采用稳健Z比分数法评价测量数据的一致性。结果表明,射频综合场强测量比对中,9台仪器测量结果满意,1台仪器测量结果离群。工频电磁场测量比对中,有9台仪器测量结果满意,2台仪器测量结果离群。88%的测量值为满意结果,12%为离群结果,测量比对有效地发现了测量仪器存在的问题,保证监测工作结果的准确性。  相似文献   

10.
为了保证辐射监测数据的准确,江苏省辐射环境监测管理站组织了2011年全省环境γ辐射剂量率测量比对。结果表明,22台仪器测量结果满意,1台仪器测量数据可疑,所有仪器均未出现不满意或离群结果。测量比对有效地发现了测量存在的问题,保证监测工作结果的准确性。  相似文献   

11.
两种环境应急监测仪器在突发性环境污染事故中的作用   总被引:2,自引:0,他引:2  
突发性环境污染事故虽然出现频率小,但危害极大,是威胁人类健康、破坏生态环境的重要因素。对于突发性污染事故的应急监测和处置,必须做到及时、快速、简便、准确。在某次苯泄漏事故的应急监测中,采用先进的傅里叶红外便携式气体分析仪监测环境空气质量,采用便携式气相色谱仪监测水质,结果表明,便捷、高效的监测仪器为此次污染事故的成功处置提供了技术支持,为以后类似突发污染事故的应急监测提供了参考。  相似文献   

12.
浅谈环境有机污染物监测发展趋势   总被引:4,自引:0,他引:4  
从监测种类、环境介质、前处理设备、检测仪器、分析方法及质量保证/质量控制等方面,简述了环境有机污染物监测的发展趋势。指出污染物的监测种类将不断增多,监控介质将多样化,前处理设备趋于自动化,检测仪器呈现联用化,监测方法的标准化进程将加快,质量保证/质量控制将更加合理化和科学化。  相似文献   

13.
为研究PM_(2.5)和PM_(10)手工与自动监测仪器在高海拔地区的适用性,于2014年12月至2015年1月(冬季)在青海省西宁市开展了为期34 d的监测比对实验。PM监测数据表明:手工监测数据之间都有差异,除了受监测滤膜种类的影响,还存在监测仪器间的系统误差。石英滤膜的PM监测数据都高于聚丙烯滤膜,尤其是PM_(2.5)更为明显,偏高近1/4;石英滤膜与聚丙烯滤膜的PM监测数据具有较好的相关性,PM_(10)监测数据的相关系数为0.97。自动监测数据之间进行了同期比对研究,发现TEOM1405DF(微振荡天平法)和APM-2(β射线法)的PM监测值较低,BAM-1020(β射线法)的PM监测值最高;而Grimm(光散射法)的PM监测值居中。BAM1020配备动态加热系统(DHS),其PM监测数据比没有配备DHS的APM-2偏高40%。基于PM监测比对研究,建议在空气污染严重时加密对各监测仪器的运行维护,并加强长期观测以全面评估PM监测。  相似文献   

14.
Control of workplace exposure to beryllium is a growing issue in the United States and other nations. As the health risks associated with low-level exposure to beryllium are better understood, the need increases for improved analytical techniques both in the laboratory and in the field. These techniques also require a greater degree of standardization to permit reliable comparison of data obtained from different locations and at different times. Analysis of low-level beryllium samples, in the form of air filters or surface wipes, is frequently required for workplace monitoring or to provide data to support decision-making on implementation of exposure controls. In the United States and the United Kingdom, the current permissible exposure level is 2 microg m(-3) (air) and the United States Department of Energy has implemented an action level of 0.2 microg m(-3) (air) and 0.2 microg/100 cm(2) (surface). These low-level samples present a number of analytical challenges, including (1) a lack of suitable standard reference materials, (2) unknown robustness of sample preparation techniques, (3) interferences during analysis, (4) sensitivity (sufficiently low detection limits), (5) specificity (beryllium speciation) and (6) data comparability among laboratories. Additionally, there is a need for portable, real-time (or near real-time) equipment for beryllium air monitoring and surface wipe analysis that is both laboratory-validated and field-validated in a manner that would be accepted by national and/or international standards organizations. This paper provides a review of the current analytical requirements for trace-level beryllium analysis for worker protection and also addresses issues that may change those requirements. The current analytical state of the art and relevant challenges facing the analytical community will be presented, followed by suggested criteria for real-time monitoring equipment. Recognizing and addressing these challenges will present opportunities for laboratories, research and development organizations, instrument manufacturers and others.  相似文献   

15.
大气降尘量是重要的环境指标之一,可以较客观地反映和评价城市局部地区扬尘污染水平,对评价城市区域环境空气质量、分析大气污染来源和变化具有重要意义。国内外大气降尘监测普遍采用传统的手工监测方法,手工法因时效性差、效率低、能耗大、质控难、误差大等原因已不适应现代环境管理的需求。随着科技与网络的发展,自动监测方法成为发展趋势。文章主要阐述了上海市降尘自动监测技术的研发过程及实际应用,介绍了自主研发的降尘自动监测仪的原理、关键技术和系统组成。通过粉尘舱内实验、降尘自动监测方法与手工重量法比对测试及为期一年的试点应用,分析了降尘自动监测方法的精密度、准确度、相对误差及适用性,并探讨了降尘自动监测的应用前景。  相似文献   

16.
新疆城市环境空气PM_(10)自动监测仪器质控巡检工作探析   总被引:1,自引:0,他引:1  
随着城市环境空气质量自动监测业务现代化的飞速发展,新疆城市共安装38套PM10环境空气自动监测系统。本文通过对新疆19个城市空气自动监测系统PM10的巡检和质控考核,发现近几年来该系统运行维护中的诸多问题,从而提出仪器维护注意事项,以期提高新疆城市PM10监测数据质量,准确反映环境空气质量状况,为环境管理和政府决策提供更加科学、准确、可靠的基础监测数据。  相似文献   

17.
以环境监测管理各项法规政策、空气自动监测技术规范和方法标准的技术规定及管理要求为准绳,研究搭建环境空气自动监测质量管理总框架,制定体系化的环境空气自动监测质量管理框架体系及管理文件规程,从而规范环境空气自动监测活动,提高空气自动监测数据的科学性和准确性,为环境保护管理部门实施环境空气预报预警及规划空气污染治理各项工作奠定坚实基础。  相似文献   

18.
概述了各地在构建水质自动监测管理系统上的探索和不足。构建了水质自动监测管理系统,统一应用平台,利用仪器仪表标识集,实施监测数据辅助审核,完善数据预警统计分析功能;通过平台对现场端仪器自动巡检,实现数据集中化管理,完善水质自动监测质量控制体系,满足了环境管理需求。  相似文献   

19.
有机硫化物是环境空气典型恶臭物质,因环境浓度低和化学稳定性差,其定性定量分析是公认的难题。研究筛选5台市场主流有机硫自动分析仪,在石化园区开展实测以考察仪器在复杂环境下的适用性。结果表明:各仪器能对环境空气中有机硫物质持续有效监测,多数仪器所测甲硫醇、甲硫醚、二甲二硫醚和二硫化碳浓度的时间变化趋势较一致,其中D和E仪器的4种有机硫监测数据均呈显著相关,其相关系数分别为0.67、0.80、0.67和0.70(P0.01)。不同仪器测得有机硫数据呈正偏态分布,但浓度分布区间差异较大,表明部分仪器对污染物的富集、脱附和检测等环节仍需改进。D和E仪器监测的有机硫浓度明显升高时,监测点位附近的GC-FID/PID测得总挥发性有机物浓度较其他时段升高,且周边区域异味投诉量增加,说明这2台仪器监测数据能较好地反映该园区有机硫化物的污染特征。研究可为石化园区有机硫自动监测仪的设备选型提供依据。  相似文献   

20.
For the health and safety of the public, it is essential to measure spatiotemporal distribution of air pollution in a region and thus monitor air quality in a fine-grain manner. While most of the sensing-based commercial applications available until today have been using fixed environmental sensors, the use of personal devices such as smartphones, smartwatches, and other wearable devices has not been explored in depth. These kinds of devices have an advantage of being with the user continuously, thus providing an ability to generate accurate and well-distributed spatiotemporal air pollution data. In this paper, we review the studies (especially in the last decade) done by various researchers using different kinds of environmental sensors highlighting related techniques and issues. We also present important studies of measuring impact and emission of air pollution on human beings and also discuss models using which air pollution inhalation can be associated to humans by quantifying personal exposure with the use of human activity detection. The overarching aim of this review is to provide novel and key ideas that have the potential to drive pervasive and individual centric and yet accurate pollution monitoring techniques which can scale up to the future needs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号