首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
贵阳室内氡时空分布特征研究   总被引:1,自引:0,他引:1  
为了全面分析室内氡的时空分布特征、来源和影响因素,选择了贵阳市不同地理位置的居民住宅、办公场所和公共场所,进行了为期一年的室内氡监测。贵阳市室内氡的平均浓度为(72.7±1.6)Bq/m3,低于室内空气污染国家标准,达标率98.5%。其中居民住宅、办公场所和公共场所的室内氡浓度分别为(93.46±86.93)、(74.68±40.74)、(61±26.93)Bq/m3。研究表明,室内涂料、装修程度和通风效果、小区环境等对室内氡浓度高低有显著影响,室内氡也随季节变化而发生波动。对于居民住宅和公共场所氡的室内外来源相对重要性不同。居民住宅内新楼和旧楼不同楼层室内氡的来源、影响因素和分布特征有显著差异。  相似文献   

2.
Environmental monitoring and indoor radon measurement are important for public health, to estimate the cancer risk of respiratory system and, if necessary, to suggest proper methods that reduce indoor radon level. In this research, indoor radon concentration in the air has been measured in 150 apartments in Mashhad city. The result demonstrates about 94.7% of apartments have radon concentration less than 100 Bq/m3, taken by WHO as the action level, and 5.3% have the concentration higher than this level. As well as, annual radon dose has been assessed using the equation for annual effective dose calculation introduced by United Nations Scientific Committee on the Effects of Atomic Radiation.  相似文献   

3.
The paper presents the results of radon concentration measurements in the vicinity of water, indoor air and in contact to building walls. The investigations were carried out using CR-39 track detectors. Samples of ground water flowing out of many springs mostly in Arabian Gulf area except one from Germany have been studied. The results are compared with international recommendations and the values are found to be lower than the recommended value. Measuring the mean indoor radon concentrations in air and in contact to building walls in the dwellings of Kuwait University Campus were found 24.2 +/- 7.7, and 462 +/- 422 Bq m(-3) respectively. These values lead to average effective dose equivalent rates of 1.3 +/- 0.4 and 23 +/- 21 mSv year(-1), respectively.  相似文献   

4.
Understanding soil gas radon spatial variations can allow the constructor of a new house to prevent radon gas flowing from the ground. Indoor radon concentration distribution depends on many parameters and it is difficult to use its spatial variation to assess radon potential. Many scientists use to measure outdoor soil gas radon concentrations to assess the radon potential. Geostatistical methods provide us a valuable tool to study spatial structure of radon concentration and mapping. To explore the structure of soil gas radon concentration within an area in south Italy and choice a kriging algorithm, we compared the prediction performances of four different kriging algorithms: ordinary kriging, lognormal kriging, ordinary multi-Gaussian kriging, and ordinary indicator cokriging. Their results were compared using an independent validation data set. The comparison of predictions was based on three measures of accuracy: (1) the mean absolute error, (2) the mean-squared error of prediction; (3) the mean relative error, and a measure of effectiveness: the goodness-of-prediction estimate. The results obtained in this case study showed that the multi-Gaussian kriging was the most accurate approach among those considered. Comparing radon anomalies with lithology and fault locations, no evidence of a strict correlation between type of outcropping terrain and radon anomalies was found, except in the western sector where there were granitic and gneissic terrain. Moreover, there was a clear correlation between radon anomalies and fault systems.  相似文献   

5.
根据重庆市城市组团式建设特点,采用径迹法对重庆市主城建成区开展室内氡浓度调查。结果表明,各区县室内氡浓度整体水平较低,重庆市主城区室内氡浓度平均值为64.5 Bq/m3,168个采样点均小于国家标准200 Bq/m3;吸入氡及子体对人员产生的年均有效剂量均低于《住房内氡浓度控制标准》和《地下建筑氡及其子体控制标准规定》中规定的室内氡浓度行动水平。  相似文献   

6.
Most of the building materials contain naturally occurring radioactive elements, the most important of which are potassium 40K and the members of two natural radioactive series, which can be represented by the isotopes of thorium 232Th and Uranium 238U. The presence of these radioisotopes in the materials causes external exposure to the people who live in the building. In addition, the disintegration of Uranium 238U increases the concentration of radon gas 222Rn and of its daughters in the house. So a systematic indoor gamma dose measurement has been performed in the dwellings of Agastheeswaram Taluk of Kanyakumari district, which is lying within the 30 km radius from the upcoming Kudankulam nuclear power plant site. The geometric mean of annual absorbed dose from gamma radiation in dwellings has been found to be 278 nGyh−1. The seasonal variation of indoor gamma dose measurements has also been studied. Significant differences have been observed in dwellings built of different materials such as concrete, tiled, etc.  相似文献   

7.
It is well established that some areas of Himachal Pradesh (H.P.) state of India situated in the environs of the Himalayan mountains are relatively rich in uranium-bearing minerals. Some earlier studies by our group have indicated high levels of radon (>200 Bq m(-3)) in the dwellings. It is in this context that an indoor radon/thoron survey has been carried out in selected villages of four districts in the state of H.P. This survey has been conducted as a part of a national, coordinated project using twin chamber dosemeter cups designed by the Environmental Assessment Division (EAD), Department of Atomic Energy, Govt. of India. The track-etch technique is used for calibration of plastic detector LR-115 type-II which are employed for recording alpha tracks due to radon/thoron and their daughters. Year long radon/thoron data have been collected for seasonal correlations of indoor radon/thoron in the dwellings. The indoor radon levels have been found to vary from a minimum value of 17.4 Bq m(-3) to a maximum value of 140.3 Bq m(-3). The indoor thoron levels vary from a minimum value of 5.2 Bq m(-3) to a maximum value of 131.9 Bq m(-3). The year average dose rate for the local population varies from 0.03 microSv h(-1) to 0.83 microSv h(-1). The annual exposure dose to inhabitants in all the dwellings lies below the upper limit of 10 mSv given in ICRP-65.  相似文献   

8.
The renovation of a building will certainly affect the quality of air in the vicinity of where associated activities were undertaken, this includes the quality of air inside the building. Indoor air pollutants such as particulate matter, heavy metals, and fine fibers are likely to be emitted during renovation work. This study was conducted to determine the concentration of heavy metals, asbestos and suspended particulates in the Biology Building, at the Universiti Kebangsaan, Malaysia (UKM). Renovation activities were carried out widely in the laboratories which were located in this building. A low-volume sampler was used to collect suspended particulate matter of a diameter size less than 10 μm (PM??) and an air sampling pump, fitted with a cellulose ester membrane filter, were used for asbestos sampling. Dust was collected using a small brush and scope. The concentration of heavy metals was determined through the use of inductively coupled plasma-mass spectroscopy and the fibers were counted through a phase contrast microscope. The concentrations of PM?? recorded in the building during renovation action (ranging from 166 to 542 μg m?3) were higher than the value set by the Department of Safety and Health for respirable dust (150 μg m?3). Additionally, they were higher than the value of PM?? recorded in indoor environments from other studies. The composition of heavy metals in PM?? and indoor dust were found to be dominated by Zn and results also showed that the concentration of heavy metals in indoor dust and PM?? in this study was higher than levels recorded in other similar studies. The asbestos concentration was 0.0038 ± 0.0011 fibers/cc. This was lower than the value set by the Malaysian Department of Occupational, Safety and Health (DOSH) regulations of 0.1 fibers/cc, but higher than the background value usually recorded in indoor environments. This study strongly suggests that renovation issues need to be considered seriously by relevant stakeholders within the university in order to ensure that the associated risks toward humans and indoor environment are eliminated, or where this is not feasible, minimized as far as possible.  相似文献   

9.
This paper examines the problem of estimating indoor radon concentrations for radon-induced lung cancer risk assessment. Previous authors have identified various problems and possible corrections for the use of generally available radon screening measurements. Bias evident in data collected from volunteers is described; regional databases developed from voluntary data generally exhibit higher mean values than those obtained from random samples. Tools are developed to better characterize the differences in voluntary and random concentration distributions. Application is demonstrated using voluntary and random radon survey data for the state of North Dakota.  相似文献   

10.
The province of Batman, located in southern Anatolia, has a population of approximately 500,000. To our knowledge, there exists no information regarding the environmental radioactivity in this province. Therefore, gamma activity measurements in soil, building materials and water samples and an indoor radon survey have been carried out in the Batman province. The mean activity concentrations of the natural radionuclides (226Ra, 232Th and 40K) and a fission product (137Cs) were 35 ± 8, 25 ± 10, 274 ± 167 and 12 ± 7 Bq kg???1, respectively, in the soil samples. The concentrations of 226Ra, 232Th and 40K in the selected building materials ranged from 18 to 48 Bq kg???1, 8 to 49 Bq kg???1 and 68 to 477 Bq kg???1, respectively. All the calculated radium equivalent (Raeq) activity values of the building material samples are lower than the limit of 370 Bq kg???1, equivalent to a γ-dose of 1.5 mSv year???1. The activity concentrations of 226Ra, 232Th and 40K in tap waters collected from the study area were determined with mean specific activity concentrations of 42 ± 15, 35 ± 9 and 524 ± 190 mBq L???1, respectively. Indoor radon measurements were made at 95 dwellings in Batman using a CR-39 detector. The radon concentration levels were found to vary from 23 to 145 Bq m???3. The arithmetic mean of the measured radon concentration levels was found to be 84 Bq m???3 with a standard deviation value of 23 Bq m???3. The measurement results obtained in this study did not significantly differ from those taken in other parts of the country. The data generated in this study can be used to determine whether the Batman province is in a normal or high background radiation area and provides a valuable database for future estimations of the impact of radioactive pollution.  相似文献   

11.
Hourly measurements of radon level at four houses in Butte, Montana were analyzed. Previous studies suggestes that there are diurnal cycles, spectral analysis confirms this assertion. Moreover, there are also long term trends and weekly cycles at certain locations. The periodical cycles highly suggest that indoor radon level can be dependent on the ventilation condition of the house and the activities of the residents.The relationship of indoor and outdoor radon level was investigated by cross-spectral analysis. In view of the possible different patterns caused by different seasons, data from the winter and summer are analyzed separately. The results shows that winter and summer data do display different patterns.  相似文献   

12.
The radon concentration levels in soil samples from 39 locations of Northern Punjab are measured using AlphaGUARD (PQ 2000 PRO Model) of Genitron instruments, Germany. The radon concentration in soil varies from 0.3 to 35.8 kBq/l. The minimum value of radon is observed in Talwandi Choudhrian and is maximum for Nushera Dhala. The soil gas radon is correlated with soil temperature, pressure, and humidity to observe the effect of these parameters on radon release. The soil gas radon values in the study area are compared with that obtained in groundwater. The results are also compared with the available radon data for other parts of Punjab and Himachal Pradesh.  相似文献   

13.
Indoor environmental health is now recognized as an important factor in preventing respiratory health problems in the United States. It is also a concern in Canada due to the amount of time that Canadians spend indoors because of cold weather and the potential for increased time indoors during the summer if theclimate warms. The negative health effects are often labeled assick building syndrome, but diagnosing a building or itsoccupants as sick is complicated by the variety of symptoms, thepresence of chronic versus acute symptoms and social andpsychological (socio-psychological) factors that may reduce theeffectiveness of an engineering solution. As a case study, thecontribution of various factors to indoor environmental health,in three buildings at the University of Toronto, was examinedusing five different methods. The results indicate that theinhabitants of the buildings consider features other than airquality in considering building health such as design,maintenance, funding cuts and socio-psychological factors.  相似文献   

14.
Uranium and radon concentration was assessed in water samples taken from hand pumps, natural sources and wells collected from some areas of Upper Siwaliks, Northern India. Fission track registration technique was used to estimate the uranium content of water samples. The uranium concentration in water samples was found to vary from 1.08 +/- 0.03 to 19.68 +/- 0.12 microg l(-1). These values were compared with safe limit values recommended for drinking water. Most of the water samples were found to have uranium concentration below the safe limit of 15 microg l(-1) (WHO, World Health Organization, Guidelines for drinking-water quality (3rd ed.). Geneva, Switzerland: WHO, 2004). The radon estimation in these water samples was made using alpha-scintillometry to study its correlation with uranium. The radon concentration in these samples was found to vary from 0.87 +/- 0.29 to 32.10 +/- 1.79 Bq l(-1). The recorded values of radon concentration were within the recommended safe limit of 4 to 40 Bq l(-1) (UNSCEAR, United Nations Scientific Committee on the Effects of Atomic Radiations, Sources and effects of ionizing radiation. New York: United Nations, 1993). No direct correlation was found between uranium concentration and radon concentration in water samples belonging to Upper Siwaliks. The values of uranium and radon concentration in water were compared with that from the adjoining areas of Punjab state, India.  相似文献   

15.
The aim of this study was to evaluate the indoor (I) and outdoor (O) levels of NO?, speciated volatile organic compounds (VOCs) and carbonyls at fourteen primary schools in Lisbon (Portugal) during spring, autumn and winter. Three of these schools were also selected to be monitored for comfort parameters, such as temperature and relative humidity, carbon dioxide (CO?), carbon monoxide (CO), total VOCs, and both bacterial and fungal colony-forming units per cubic metre. The concentration of CO? and bioaerosols greatly exceeded the acceptable maximum values of 1800 mg m?3 and 500 CFU m?3, respectively, in all seasons. Most of the assessed VOCs and carbonyls occurred at I/O ratios above unity in all seasons, thus showing the importance of indoor sources and building conditions in indoor air quality. However, it has been observed that higher indoor VOC concentrations occurred more often in the colder months, while carbonyl concentrations were higher in the warm months. In general, the I/O NO? ratios ranged between 0.35 and 1, never exceeding the unity. Some actions are suggested to improve the indoor air quality in Lisbon primary schools.  相似文献   

16.
This paper presents key elements on which to base the design of a strategy for a particular indoor environment measurement task. Starting from a general strategy for responding to occupant complaints and conducting epidemiological and intervention studies the paper concentrates on selected key elements, with focus on air contaminants. Strategies for grouping of occupants with the purpose of exposure assessment should aim at optimising exposure contrast between groups, and grouping according to buildings may not be the proper choice. Occupant exposure can be measured by personal sampling or constructed from measured concentrations in microenvironments and activity patterns. The cause of temporal and spatial variability is discussed and guidance is given on the number of samples needed to detect a given change in true concentration level. The sick building syndrome (SBS) is defined as those situations where a high proportion of building occupants are complaining about mucous membrane or skin irritation, general symptoms. When investigating SBS, questionnaires should be used to collect structured information from occupants on perception of environmental conditions, psychosocial factors and symptoms. There is as yet no consensus on choice of length of reference period for reporting symptoms and for estimating exposure. Finally, methods for identifying and quantification of sources of air contaminants are discussed, including lab-scale or full-scale simulation, on-site measurement of source emission, air monitoring, surface sampling, and modelling.  相似文献   

17.
基于MODIS AOD遥感数据,采用多元线性回归模型对PM2.5地面监测数据进行模拟估算,同时加入降水量、相对湿度等气象因子以提高模型精度,结合GIS空间分析技术,得到2015—2016年京津冀地区空间连续的PM2.5浓度分布。结果表明:利用多元线性回归模型反演PM2.5浓度效果较好,R 2均在0.59~0.84之间。在时间上,京津冀地区PM2.5浓度呈现出夏季最低、秋季稍高、冬春两季最高的变化趋势;在空间上,2015年和2016年京津冀地区PM2.5浓度有明显的区域差异,均呈现出西北低、东南高的分布格局,大致与燕山山脉和太行山脉走向一致。  相似文献   

18.
19.
Passive samplers have become more popular in their application in the measurement of airborne chemicals. For volatile organic compounds, the rate of a chemical's diffusivity is a determining factor in the quantity of the chemical being collected for a given passive sampler. While uptake rate of a chemical in the passive sampler can be determined either by collocation deployment of both active and passive samplers or use of controlled facilities such as environmental chambers, a new approach without a need for accurate active flow rate in the collocation experiment was demonstrated in this study. This approach uses chemicals of known uptake rates as references to calculate the actual flow rate of the active sampling in the collocation experiment. The active sampling rate in turn can be used in the determination of the uptake rates of all other chemicals present in the passive samplers. The advantage of such approach is the elimination of the errors in actual active sampling rate associated with low flow employed in the collocation experiment. Using this approach, passive uptake rates of more than 80 volatile organic compounds commonly present in indoor air were determined. These experimentally determined uptake rates correlate well with air diffusivity of the chemicals, indicating the regression equation describing such correlation might be useful in predicting the uptake rates of other volatile organic chemicals in indoor air based on their air diffusivity.  相似文献   

20.
The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium–low level of bacterial contamination (50–500 CFU/m3) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号