首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
A harmonised procedure for the determination of the forms of phosphorus in freshwater sediments, developed in the frame of the European Programme, Standards, Measurements and Testing (SMT) has been used for a certification campaign for a reference material. This operationally defined scheme is a good compromise between method performance and reproducibility. Furthermore, the method is rather simple to implement and could be used by water managers on a routine basis. A homogeneous and stable sediment reference material has been prepared and will be available before mid 2001. The so-called SMT protocol, together with the reference material, are useful tools in the field of water management, especially at a time when quality assurance is of paramount importance in laboratory analyses. Knowledge of the bioavailable forms of phosphorus is important not only for analysis of sediments but also for sludge and soils. Therefore, the SMT protocol could be extended to these materials.  相似文献   

2.
The composition of airborne particulate matter sampled by a conventional TEOM®, an experimental modified TEOM, operated at a lower temperature but fitted with a drier to remove moisture and a Partisol®, installed at a kerbside site in the North East of England, has been investigated. The results indicate that there is a seasonal variation in the composition of PM10 as sampled by the three monitors, with chloride concentration being significantly higher in the winter. The Partisol was found to sample a higher mass of chloride and nitrate, however the differences between the monitors was only significant for chloride. Both TEOM's were found to sample a greater mass of sulphate, although the variability in the data collected meant that significance of the results was not proven statistically. The range of artifacts associated with PM10 monitors is reviewed. Difficulties in the interpretation of results due to the variable nature of airborne particulate matter and the ability of filter based systems to accurately represent the composition of atmospheric particles are considered.  相似文献   

3.
The composition of airborne particulate matter sampled by a conventional TEOM, an experimental modified TEOM, operated at a lower temperature but fitted with a drier to remove moisture and a Partisol, installed at a kerbside site in the North East of England, has been investigated. The results indicate that there is a seasonal variation in the composition of PM(10) as sampled by the three monitors, with chloride concentration being significantly higher in the winter. The Partisol was found to sample a higher mass of chloride and nitrate, however the differences between the monitors was only significant for chloride. Both TEOM's were found to sample a greater mass of sulphate, although the variability in the data collected meant that significance of the results was not proven statistically. The range of artifacts associated with PM(10) monitors is reviewed. Difficulties in the interpretation of results due to the variable nature of airborne particulate matter and the ability of filter based systems to accurately represent the composition of atmospheric particles are considered.  相似文献   

4.
A model for simulation of solute transport in a dynamic stream–aquifer system is developed by integrating four existing sub-models. Interface packages are created to link the sub-models. The developed model is successfully used to simulate chloride transport in the stream–aquifer system of the Arkansas River and the Equus Beds Aquifer in Kansas and demonstrates that chloride concentration in the aquifer decreases in the vicinity of the simulated channel over time.  相似文献   

5.
We evaluate a field method for determining species richness andcanopy cover of vascular plants for the Forest Health MonitoringProgram (FHM), an ecological survey of U.S. forests. Measurementsare taken within 12 1-m2 quadrats on 1/15 ha plots in FHM.Species richness and cover are determined for four height classes(strata) within each quadrat and aggregated by stratum over the entireplot. We estimated (1) the agreement between experienced trainers andinexperienced technicians who collected the data on this survey(accuracy) and (2) the agreement among the technicians (precision) forresults on species richness and cover from 3 test plots at 3 timeintervals. The methods appear to be highly precise, although somediscrepancies with the values obtained by the trainers were found.Trainers found significantly more species in the ground stratum (0–0.6 m) and measured significantly more cover in the uppermost stratum(>4.9 m). The proportion of variation due to measurement error andtemporal variability was less than 13% for species richness (all strata)and cover (all but one stratum). This indicates that the method issuitable for monitoring changes in species richness and canopy coverfor a large-scale synoptic monitoring project such as FHM.  相似文献   

6.
Sewage treatment works are one of the major sources that cause atmospheric odour pollution. The increase in the number of complaints about odour nuisance is due to the increase in environmental concerns. Unfortunately, the legislation on odour nuisance from sewage treatment works is very limited. In order to determine suitable thresholds on which to base legal standards, reliable and efficient odour measurement methods need to be defined. A chemical sensor array was developed for the purpose of measuring wastewater odour. This paper describes the development of the chemical sensor system which is specifically tuned to odours of wastewater origin and which can give an electronic measure of the wastewater odours. Odour emissions from a wastewater treatment facility were detected by using a quartz crystal microbalance (QCM) sensor array. The array consists of nine sensor elements, which were coated with different materials. In this paper, the usage of these novel instruments in the water industry was shown.  相似文献   

7.
Considerable uncertainties are associated with the experimental estimates of emission rates of different volatile organic compound (VOC) species from the biosphere to the atmosphere. Some of this uncertainty derives from the sampling and analytical procedures used in emission rate measurements. A calibration system was developed in order to evaluate possible errors in the measurements of biogenic emission rates using a branch enclosure system. Two types of calibration procedures were tested, a standard additions technique and an internal standard procedure. Both techniques were used to evaluate possible losses while sampling isoprene and monoterpenes, which are the most abundant VOCs of biogenic origin. The losses to Teflon lines and the empty sampling system were tested and losses to the branch enclosure system installed on two VOC emitting plant species were evaluated. A considerable loss of isoprene (approximately 18% of inflow concentration 65 ng l(-1)) to the empty enclosure system and to the system installed on the plant was measured, but no losses of monoterpenes were observed.  相似文献   

8.
This study aims to determine changes in the structure of cryptogamic vegetation of poor psammophilous grassland along a pollution gradient near a zinc smelter to evaluate the potential of species assemblages as bioindicators of soil condition. Lichens and bryophytes were examined in study plots along six transects in four distance zones, and the physicochemical properties of corresponding soil samples were analysed. Four different responses of species to substrate contamination were identified, with a distinct group of species resistant to and favoured by metal contamination. Although species richness decreases as one approaches the smelter, the gradual replacement of certain sensitive species by resistant ones was observed along the pollution gradient. The results enabled us to develop a useful tool to diagnose strongly polluted sites. Two different cryptogamic assemblages of well-recognised key species characteristic for strongly polluted and lightly polluted sites were distinguished. We conclude that cryptogamic community structure clearly corresponds to the degree of soil contamination, thus demonstrating high bioindicative value. The study confirmed the high relevance of the community approach in metal pollution biomonitoring.  相似文献   

9.
In this study, samples from a sewage treatment lagoon and those from a receiving stream were analyzed for their phthalate esters content. Knowledge of the distribution of ubiquitous phthalate esters in the sewage lagoon and the receiving stream was necessary because of the reports of their subtle toxicity to aquatic biota and humans. Liquid–liquid extraction, Clean-up experiment and High Performance Liquid Chromatography (HPLC) were the methods employed for the quantitative determination of the Phthalates. A study of uncontaminated water was done to establish blank levels. The sewage lagoon and the receiving stream were grossly polluted as several phthalate ester plasticizers: DMP, DEP, DPhP, DBP, DEHP, DOP and DINP were found present at monthly mean levels of between 24.02 mg/L and 139.25 mg/L in the sewage treatment lagoon and 10.41 mg/L and 80.53 mg/L in the receiving stream. The results showed higher levels of phthalate esters in the sewage lagoon compared to the receiving stream. The sewage lagoon was identified as a pollution point source into the receiving stream. Levels of phthalates obtained from the receiving stream are much higher than the water criteria of 3 μg/L phthalates recommended by the United States Environmental Protection Agency (USEPA) for the protection of fish and other aquatic life in water and the Suggested No-Adverse Effect Levels (SNAEL) of 7.5–38.5 μg/L for drinking water. This should give cause for great environmental concern. Peoples’ health downstream is at stake and so is the ‘health’ of the ecosystem.  相似文献   

10.
Intra-tidal variability in the transport of materials through the Cochin estuary was studied over successive spring and neap tides to estimate the export fluxes of nutrients and chlorophyll a into the adjoining coastal zone. The results showed that there was a substantial increase in the freshwater flow into the estuary following heavy rains (~126 mm) prior to the spring tide observations. The estuary responded accordingly with a relatively larger export through the Cochin inlet during spring tide over neap tide. Despite an increased freshwater discharge during spring tide, the export fluxes of phosphate and ammonia were high during neap tide due to their input into the estuary through anthropogenic activities. The significance of this study is that the export fluxes from the Cochin estuary could be a major factor sustaining the spectacular monsoon fishery along the southwest coast of India.  相似文献   

11.
Water quality monitoring network design has historically tended to use experience, intuition and subjective judgement in locating monitoring stations. Better design procedures to optimize monitoring systems need to simultaneously identify significant planning objectives and consider a number of social, economic and environmental constraints. The consideration of multiple objectives may require further decision analysis to determine the preference weights associated with the objectives to aid in the decision-making process. This may require the application of an optimization study to extract such information from decision makers or experts and to evaluate the overall effectiveness of locating strategies. This paper assesses the optimal expansion and relocation strategies of a water quality monitoring network using a two-stage analysis. The first stage focuses on the information retrieval of preference weights with respect to the designated planning objectives. With the aid of a pre-emptive goal programming model, data analysis is applied to obtain the essential information from the questionnaire outputs. The second stage then utilizes a weighted multi-objective optimization approach to search for the optimal locating strategies of the monitoring stations in the river basin. Practical implementation is illustrated by a case study in the Kao-Ping River Basin, south Taiwan.  相似文献   

12.
Towards a Simple Indicator of Biodiversity   总被引:1,自引:0,他引:1  
Policy makers in Canada have suggested that the scientific community should develop an indicator of biodiversity change that can be implemented quite quickly without a major new investment in monitoring systems. We propose that such an indicator can be developed from the theory of species gradients in community ecology. The term 'species gradients' refers to the increasing diversity of species through time under stable conditions, and the increasing diversity of species with the increased use of available resources. This theory is reviewed under four different headings: evolutionary ecology, the energy theory, the resource productivity theory and the thermodynamic mechanism. The theoretical arguments provide a basis to propose detection of the 'leaky ecosystem' as an indicator of biodiversity. We propose that it is possible to detect the leaky energetics of ecosystems by means of routinely available observations of outgoing longwave radiation.  相似文献   

13.
A selection of turbulence data corresponding to 185 days of field measurements has been analysed. The non-ideal building geometry influenced the circulation patterns in the street canyon and the largest average vertical velocities were observed in the wake of an unbroken line of buildings. The standard deviation of vertical velocity fluctuations normalised by the ambient wind speed was relatively insensitive to ambient wind direction and sensor position, and it was usually larger than the corresponding 1-hour average velocity. Cross-correlations of spatially separated velocity measurements were small, and this suggests that most of the velocity fluctuations were fairly local and not caused by unsteady street vortices. The observed velocities scaled with the ambient wind speed except under low-wind conditions.  相似文献   

14.
We show that the Annual Forest Inventory System (AFIS) being developed by the USDA Forest Service and tested in the state of Minnesota is no more costly than the periodic Minnesota forest inventory (12 year measurement cycle). Since very useful results could be generated with AFIS every 4 years in addition to the results from the periodic survey, a continuous inventory would be cost effective. Periodic surveys yield more precise estimates within the first few years of the full survey but afterwards the annual survey would be more precise. Where the changeover in precision occurs still needs to be determined. This cost-neutral advantage of AFIS is quite important to note since the USFS has decided to go to annualized inventories such as AFIS this year.  相似文献   

15.
This research compared the structural and chemical characteristics among dissolved organic matter (DOM) fractions within the same source and among different origins. Samples taken from the Taiping Wastewater Treatment Plant (TWTP) (Harbin, China) and from the Songhuajing River (SR), Heilongjiang Province, China were chosen to represent waters containing DOM of wastewater origin and of natural-water origin, respectively. DOM was fractionated using XAD resins into five fractions: hydrophobic acid (HPO-A), hydrophobic neutral (HPO-N), transphilic acid (TPI-A), transphilic neutral (TPI-N) and hydrophilic fraction (HPI). The SR fractions were more UV-sensitive and more reactive with chlorine in formation of trihalomethanes (THMs) than the TWTP secondary effluent (TSE) fractions. The aromatic character peaks in the Fourier-transform infrared (FT-IR) spectra of SR fractions were clearer than those of TSE fractions. On the other hand, the peaks of carbohydrates in TSE fractions were more prominent in comparison with SR fractions. In addition, the amide-2 peak was present in the spectra of all the five TSE fractions but not visible in the spectra of SR fractions. The fluorescence results showed that SR DOM fractions contained more fulvic acid-like fluorescent compounds while TSE DOM fractions had higher amounts of protein-like fluorescent components.  相似文献   

16.
A totally automated solid phase extraction gas chromatography procedure was developed for the sampling and analysis of carbonyl compounds in air. In this system, two PrepStation modules were used, one for the preparation and elution of 2,4-dinitrophenylhydrazine silica cartridges, and the other for air sampling. The sample collected by the sampling module was eluted to an autosampler vial in the PrepStation module and then transferred to the gas chromatograph for analysis via a robotic arm. The sampling module was modified to enable air sampling via an external pump. A typical run by this technique required 142 min, 100 min for air sampling and 42 min for the other operations, including a GC analysis time of 25 min. Recoveries of at least 85% were obtained for all compounds studied. The detection limits for formaldehyde, acetaldehyde and acetone were 2.2, 2.7 and 2.2 ppbv, respectively. All operations, including the conditioning of the cartridges, were performed without any intervention from the analyst.  相似文献   

17.
A series of tests is described that measured the concentration of aerosol ingredients in a test room for a period of several hours after spraying. The results were compared to a simple exponential decay model used by the industry to predict exposure to aerosol ingredients. The results showed that the model can be used to predict exposure once the ingredients had become dispersed throughout the room, and that the exposure dose is initially heavily influenced by location during the period soon after spraying.  相似文献   

18.
源强确定在突发污染事故的预警与应急过程中极为重要。本文针对树状河流的特性,将污染源搜索和源强反算的方法结合起来构建了树状河流突发污染事故源强确定的一般方法,并利于假设的突发污染事故情形对方法就行了评估。结果表明,监测数据的误差对计算结果的影响很大,源强的计算结果相比事故的地点与发生时间更为敏感。  相似文献   

19.
During periods of two weeks in February and June 2010 the performance of portable air treatment units (PATUs) was evaluated in a primary school classroom using indicators of indoor air quality. Air samples were collected in an undisturbed setting on weekend days and in an occupied setting during teaching hours. In the first week PATUs were turned off and in the second week they were turned on. On weekend days PATUs reduced indoor levels of PM-10 by 87% in February and by 70% in June compared to weekend days when PATUs were turned off. On schooldays, indoor PM-10 was increased by 6% in February and reduced by 42% in June. For PM-2.5 reductions on weekend days were 89% in February and 80% in June. On school days PM-2.5 was increased by 15% in February and reduced by 83% in June. Turning on the PATUs reduced total VOC by 80% on weekend days and by 57% on school days (but not in June). No influence on formaldehyde, NO(2), O(3) and molds was observed. PATUs appeared to be less effective in removal of air pollutants when used in an occupied classroom compared to an unoccupied setting. Our study suggests that such devices should be tested in real-life settings to evaluate their influence on indoor air quality.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏