1.
The effect of the injection of brominated powdered activated carbon (Br-PAC) on the emission of brominated and chlorinated dioxins and furans in coal combustion flue gas has been evaluated. The sampling campaigns were performed at two U.S. Department of Energy (DOE) demonstration sites where brominated PAC was being injected for control of mercury emissions. The results of the sampling campaigns showed that injection of the brominated PAC upstream of the electrostatic precipitator (ESP) did not increase the emissions of total and Toxic EQuivalent (TEQ) chlorinated and brominated dioxin compounds. Rather, the data suggested the sorbent may capture these compounds and reduce their concentration in the flue gas stream. This effect, when seen, was small, and independent of the type of plant emission controls, temperature at the point of injection, or fuel-chlorine content. The addition of the brominated PAC sorbent resulted in slight increases the total content of chlorinated dioxins and furan in the particulate matter (ash) collected in the ESP, but did not increase its overall toxicity.  相似文献   

2.
As one of the countries with large amounts of dioxin releases, the control of dioxins is a major challenge for China. Municipal solid waste (MSW) incineration should be considered a high priority source of dioxin emissions because it is playing an increasingly more important role in waste management. MSW incineration in China has much higher emission rates of dioxins than in the developed countries, partially resulting from the gaps in the technologies of incineration and flue gas cleaning. Moreover, the current management policies and practices also contribute significantly to the problem. We recommend lowering dioxin emission standard, strengthening fly ash management, and improving regulation enforcement to reduce dioxin releases into the environment from MSW incineration. We also propose that alternative strategies should be considered on dioxin control and call for an expansion of economic instruments in waste management to reduce waste generation and thus the need for incineration.  相似文献   

3.
Noma Y  Yamamoto T  Giraud R  Sakai S 《Chemosphere》2006,62(7):1183-1195
In the first known study to characterize the emissions of polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs) from the thermal treatment of wastes containing PCNs, the formation and decomposition behavior of these pollutants was investigated both at laboratory scale and at plant scale. Exhaust gas measurements from laboratory-scale combustion of rubber belts containing PCNs (FB belts) were used as the basis for calculations predicting that the incremental dioxin toxic equivalency (TEQ) emissions from municipal solid waste (MSW) incinerators would be less than 0.1 ng/m3 N. In order to directly examine co-incineration of FB belts with MSW and to address potential differences between the laboratory experiment and full-scale MSW incinerators, experiments were conducted using a larger scale thermal treatment test facility with sampling and analysis at several points in the thermal treatment process. Congener specific analysis of PCNs clearly showed that both destruction and synthesis simultaneously occurred during combustion in the kiln. Most of the PCNs were destroyed by secondary combustion, and almost all PCNs were removed after flue gas treatment. Almost all PCDDs/DFs were synthesized as by-products of kiln combustion, most of them were destroyed by the secondary combustion, and almost all dioxins (PCDDs/DFs and dl-PCBs) were removed after flue gas treatment. The TEQ emission levels were less than 0.1 ng/m3 N for all plant-scale tests, and differences in TEQ emission levels were very small. Adding wastes containing PCNs to MSW will not influence thermal treatment emissions to the environment from modern solid waste incinerators.  相似文献   

4.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

5.
Chang MB  Huang HC  Tsai SS  Chi KH  Chang-Chien GP 《Chemosphere》2006,62(11):1761-1773
Distribution of PCDD/F (polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran) congeners at two electric arc furnaces (EAFs) in Taiwan is evaluated via intensive stack sampling and analysis. Two kinds of exhaust system in EAFs including stack system and shutter system are selected for measuring dioxin emissions. In addition, dioxin emissions during oxidation and reduction stages at EAF-A were characterized. Results indicate that the PCDD/F concentration of stack gas in EAF-A was 4.39 ng/N m3 while total Toxic Equivalent Quantity (TEQ) concentration was 0.35 ng I-TEQ/N m3. The PCDD/F concentration of stack gas in EAF-B was 2.20 ng/N m3 and the TEQ concentration was 0.14 ng I-TEQ/N m3. 1,2,3,4,6,7,8-HpCDF, OCDD and OCDF are the major contributors of the dioxin concentrations for two EAFs investigated and the percentage of PCDD/F in particulate phase increases as the chlorination level of the PCDD/F congener increases. The results obtained on gas/particulate partitioning of PCDD/Fs in flue gases prior to the APCD in EAFs indicate that more than 90% exists in particulate phase. In EAF-A, the PCDD/F concentration during oxidation stage is slightly higher than that measured during reduction stage, including the sampling points of CO converter outlet, prior to bag filter and stack. Majority of PCDD/Fs emitted from steel-making processes exists in particulate-phase (about 60–70%) at both EAFs investigated.  相似文献   

6.
Steps towards a European dioxin emission inventory   总被引:7,自引:0,他引:7  
Quass U  Fermann MW  Bröker G 《Chemosphere》2000,40(9-11):1125-1129
The results of a project aiming at collection and evaluation of information regarding the industrial and non-industrial emission sources for dioxins and furans (PCDD/PCDF) in 17 European Countries (EU 15, CH, N) are presented. An overview about national documents covering dioxin emission inventories for the period 1990-1995 is given. Some data on emissions associated with residual materials, waste and waste water are presented additionally. Based on the air emission data contained in these documents the most important emission sources were determined which are assumed to cover about 90% of the overall emissions. For the selected sources and for all 17 countries new estimates of the atmospheric PCDD/PCDF emissions were derived from average emission factors and statistical activity rates for the year 1994. As a result, on the European scale the largest annual PCDD/PCDF emission is assessed to be released from municipal waste incineration, quite closely followed by emissions from iron ore sintering. Considerable releases of dioxins and furans--based, however, on highly uncertain data--are further assessed for domestic burning, accidental fires and (former) use of contaminated wood preservatives (pentachlorophenol). A lower but still significant emission is further assigned to the sector of non-ferrous metal production; particular processes used in this branch proved to generate very high PCDD/PCDF flue gas concentrations.  相似文献   

7.
Hart JR 《Chemosphere》2004,54(10):1539-1547
Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (dioxins) have been found from 57 field tests on the oxidation of low (a few to a few hundred) parts per million levels of chlorinated and non-chlorinated volatile organic compounds (VOCs). The oxidation occurs in catalytic oxidizers with platinum, platinum/palladium or chromium(IV) oxide combustion catalysts, or in thermal oxidizers (without a catalyst). The catalyst inlet temperatures ranged from 293 to 573 degrees C. The thermal oxidizer operating temperatures (post-flame) were from 773 to 927 degrees C. Data of the toxic dioxin and furan isomers are reported and also weighted and expressed as international toxic equivalents (TEQ) of 2,3,7,8-tetrachlorodibenzo-p-dioxin. The maximum stack emissions, 1.07 ng/m3 TEQ, occurred at 293 degrees C. Salient results of this field study are: (1) TEQ levels in the stack exponentially increase with a decrease in operating temperature, an empirical equation is TEQ (ng/dscm)=8.4 exp(-0.0084T degrees C); (2) dioxin/furan production occurs at the combustion catalyst; (3) small variations in temperature cause large changes in the congener distribution of the dioxin and furan isomers; (4) molar TEQ yields from the parent compounds fed to the oxidizers are very small (10(-9)-10(-13)); (5) catalytic and thermal oxidizers may destroy dioxins fed from the ambient air; and (6) the oxidation of chlorinated VOCs with non-chlorinated VOCs reduces emissions of dioxins, likely due to the consumption of Cl in producing HCl. Laboratory investigations are needed to understand how dioxins are formed (and emitted) under conditions of this study.  相似文献   

8.
Dioxin analyses using a DB5MS chromatography column are presented for samples of dust from an electrostatic precipitator and emissions from the main stack of a UK sinter plant. The analyses have been repeated using the SP2331 column, for which the elution order has been determined for the whole range of tetra to octachlorodibenzo-p-dioxins and dibenzofurans, and which provides a larger degree of separation than the DB5MS column. Polychlorinated dibenzofurans are present in significantly larger amounts in both the dust and stack emissions, and are the main contributors to the I-TEQ. Analysis using the SP2331 column for dioxins show considerable similarity to those of Bacher et al. for soot from a wood-burning fire, but differ markedly from those of Addink et al. for simulation of waste incineration. The similarities to Bacher's results are less for the dibenzofurans. Comparison of absolute concentrations with reported vapour pressures shows the retention of significant dioxin in the dust to involve mechanisms other than pure condensation.  相似文献   

9.
Abad E  Caixach J  Rivera J 《Chemosphere》2003,50(9):1175-1182
This study presents the results of a dioxin abatement programme undertaken in the municipal waste incineration plant of Montcada i Reixac (Barcelona, Spain) after the replacement of an obsolete air cleaning device by a new flue gas treatment system. A number of sampling campaigns were conducted with the aim of characterising stack gas emission levels of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and to evaluate initial specifications of dioxin stack gas emission values below 0.1 ng I-TEQ/Nm(3). Preliminary results revealed levels between 44 and 111 ng I-TEQ/Nm(3) when the gas-cleaning system consisted only of an old electrostatic precipitator (ESP). Decreased levels around 15 ng I-TEQ/Nm(3) were observed when the semi-dry scrubber began to operate and the ESP was switched off. Again, remarkable dioxin removal was observed after the installation of the fabric filter and levels around 0.3-0.4 ng I-TEQ/Nm(3) were soon achieved. Nevertheless, the limit of 0.1 ng I-TEQ/Nm(3) was reached by additional injection of activated carbon which helped to lower PCDD/PCDF levels to around 0.036 ng I-TEQ/Nm(3). The results also demonstrated a significant change in the dioxin distribution present in combustion-derived materials (stack gas emission, bottom ash and solid waste from gas treatment). The major dioxin fraction was found in gaseous matrices before the flue gas control system was upgraded. After this step, the major dioxin fraction content was observed in solid waste from gas treatment.  相似文献   

10.
The emission inventory of PCDD/PCDF in Taiwan   总被引:6,自引:0,他引:6  
Chen CM 《Chemosphere》2004,54(10):1413-1420
Establishment of a country or region-based dioxin inventory was considered a crucial step toward elimination of worldwide dioxins/POPs contaminations, although no harmonized method for the preparation of an inventory is available at present. In this study, we used limited data and information to generate an inventory of dioxin emissions from some major sources in Taiwan. A total of 67.25 g I-TEQ of dioxins released annually was estimated. Unlike most of the industrialized countries, municipal waste incineration is not the highest contributor for dioxins released into the atmosphere. In contrast, secondary copper smelting accounts for more than 39% of the total dioxin emissions, and is higher than those from all waste incinerators combined (23.7%). Cement kilns and electric arc furnaces for steels also produced significant portion (both >10%) of dioxins into the environment, followed by secondary aluminum smelting (6.53%), industrial oil combustion (5.02%) and power plants fueled by coal (5.01%). Other known sources are either insignificant with respect to their dioxin emissions or not included in this inventory due to lack of information or uncertainty of the results. Data presented in this report provide a general picture of dioxin emissions in Taiwan, but were mostly based on less reliable or representative information, especially with respect to emission factors from different emission sources. It is necessary to establish background information relative to our own environment at present. Upon available, the inventory should be updated accordingly for proper environmental management on dioxins.  相似文献   

11.
The first reports that it is possible to emit dioxins from the heat and power generation sector are from the beginning of the 1980s. Detailed research proved that the emission of dioxins might occur during combustion of hard coal, brown coal, and furnace oil as well as coke-oven gas. The emission of dioxins occurs in wood incineration; wood that is clean and understood as biomass; or, in particular, wood waste (polluted). This paper thoroughly discusses the mechanism of dioxin formation in thermal processes, first and foremost in combustion processes. The parameters influencing the quantity of dioxins formed and the dependence of their quantity on the conditions of combustion are highlighted. Furthermore, the methods of reducing dioxin emissions from combustion processes (primary and secondary) are discussed. The most efficacious methods that may find application in the heat and power generation sector are proposed; this is relevant from the point of view of the implementation of the Stockholm Convention resolutions in Poland with regard to persistent organic pollutants.  相似文献   

12.
Nakao T  Aozasa O  Ohta S  Miyata H 《Chemosphere》2006,62(3):459-468
We investigated combustion in a small home waste incinerator and analyzed both flue gas and residual ash for formation of the dioxin-related compounds polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and coplanar polychlorinated biphenyls and their precursors polychlorinated benzenes, polychlorinated phenols, polychlorinated diphenyl ethers, and polychlorinated biphenyls. Particularly, we investigated the effect of the incinerated material's composition on both the congener ratios of released compounds and the total concentration of all congeners of each compound. Eight different samples were prepared for incineration with four samples consist entirely paper, dead leaves, natural wood, or building materials. The remaining four samples contained mostly paper, but also other components such as fiber, non-chlorine-containing plastics, chlorine-containing plastics, and copper electric wire. The presence of non-chlorine-containing plastic in combustion samples did not increase overall dioxin or dioxin-precursor emissions. In contrast, chlorine-containing plastic resulted in a several-fold increase in total polychlorinated dioxins released, in both flue gas and residual ash. Copper wire resulted in a further several-fold increase in total polychlorinated dioxins and dioxin precursors released, with one exception: the addition of chlorine-containing plastic resulted in a many-fold increase in polychlorinated biphenyls, but only a modest further increase ( approximately 52%) with the further addition of copper. Homologue ratios tended toward higher-chlorine compounds as chlorine-containing plastic and Cu were added, but the results were far from uniform. Our results show that toxic dioxin release from small home waste incinerators must be considered significant, especially if even small amounts of chlorine-containing plastics or copper are burned.  相似文献   

13.
危险废物回转式流化冷渣多段焚烧系统焚烧特性研究   总被引:1,自引:0,他引:1  
危险废物的处理和处置是摆在我国各级市政府面前的紧迫任务。然而我国已经运行的危险废物焚烧装置普遍存在回转窑挂壁结渣、热灼减率偏高和污染排放超标等问题,作者通过将回转窑和流化床特点相结合的方法提出了一种新型危险废物回转式流化冷渣多段焚烧处置装置。该装置采用回转窑(一燃室)、二燃室和流化床结合的热解-流化焚烧工艺,特别是采用控制窑头温度避免了回转窑挂壁结渣;采用流化冷渣装置延长未燃烬渣的焚烧时间,解决了热灼减率偏高问题;水冷式烟气急冷装置可以将烟气温度从1 100℃降到200℃,防止了二恶英的尾部低温再生成。该系统运行稳定可靠,可以处理医疗垃圾和大多数的固态和液态危险废物,实现了烟气污染物尤其是二恶英排放达到国家标准的目标。同时对该系统运行时窑头温度分布、二燃室炉膛出口氧量变化、回转窑和炉膛升温特性、燃烧室外壁温度分布等几方面运行数据都进行了详细的介绍,为危险废物焚烧炉的运行提供了宝贵的经验数据。  相似文献   

14.
The European dioxin air emission inventory project--final results   总被引:14,自引:0,他引:14  
Quass U  Fermann M  Bröker G 《Chemosphere》2004,54(9):1319-1327
Main results of the second stage of the so-called "European Dioxin Emission Inventory" are presented. They cover emission testing data gained from various facilities in the EU (among these the first emission measurements reported from Portugal and Greece) and some central European countries. Further, updated dioxin emission estimates for the most important emission sources in the 17 western European countries and an evaluation of the emission time trend from 1985 to 2005 are presented. The major conclusions are, that at present, iron ore sintering is likely to be the most important emission source type followed by the former "No. 1", municipal waste incineration; measurement data from a considerable number of installations are still missing, in particular from the metal industries in Spain and Italy; there still exist an unknown number of health care waste incinerators with flue gas PCDD/F concentrations above 100 ng I-TEQ/m3 which must be considered as important local sources; in general, considerable emission reduction has been achieved with respect to the industrial emission sources, whereas emissions from non-industrial sources hardly decreased; hence, in the near future the emissions from non-industrial sources are likely to exceed those from industrial installations; the goal of 90% emission reduction set in the 5th EU Action Programme will be achieved for some source types only.  相似文献   

15.
The data on dioxin and furan emissions revealed, based on individual analysis for 2,3,7,8-TCDD, TCDD, 2,3,7,8-TCDF and TCDF for the six test periods and the operation of the two RDF-fired boilers, that there is no apparent consistent relationship between the dioxin and furan emissions and the individual or combined (averaged) boiler steam flow, total flue gas flow, sidewall furnace temperature, furnace temperature at 2-second residence time, or total furnace residence time at this plant. Only RDF feeder balance begins to show a correlation. However, there was a difference between RDF-natural gas firing and RDF-only firing; the RDF-only firing had lower PCDD and PCDF emissions while consistently operating at lower excess air.

The dioxin and furan emissions from this testing are comparable to the low end of the range of these emissions measured by the U.S. EPA at resource recovery plants in the past 4 years. This may be due in part to the calculated average furnace retention of 4 to 5 seconds during Tests #4–6, with average furnace temperatures at 2-second residence time from 1650°F to 1750°F. However, there was no correlation between dioxin and furan emissions in the stack and individual boiler operation, as judged by the average concentrations of O2, CO, CO2, 1-CO/CO2), NOx, HCl, SO2, or TSP, and furnace upset conditions versus normal operation as judged by instantaneous steam flow, sidewall furnace temperature, O2, CO, NOx, or SO2.  相似文献   


16.
Raun LH  Correa O  Rifai H  Suarez M  Koenig L 《Chemosphere》2005,60(7):973-989
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (dioxins and furans) are persistent, bioaccumulative and highly toxic chemical constituents that appear in the environment at very low and difficult to measure levels. Although dioxins and furans are widely recognized as toxic contaminants needing regulation, their temporal and spatial concentration profiles and the factors impacting their partitioning and congener distribution are only moderately understood. This paper presents the results from one of the most extensive ambient air dioxin and furan sampling efforts conducted in a geographic area to date. The data consist of monthly ambient concentrations of 17 of the most toxic congeners of dioxins and furans collected at five locations in Houston, Texas over a calendar year. The results showed a total annual mean dioxin and furan congener concentration of 1047 fg/m3 and an annual mean summation operatorI-TEQ concentration of 15 fg I-TEQ/m3 (16 fg WHO-TEQ/m3). These results, when compared with proximate data from the USEPA National Dioxin Ambient Monitoring Network (NDAMN), revealed significant (at the P0.05 level) differences between Houston and the NDAMN sites, suggesting the existence of local dioxin sources. A temporal analysis of the data showed that the congener concentration distribution varies over time, depending on the level of chlorination, type of congener, and temperature. The results also suggested that the fluctuations of congener concentrations and I-TEQ concentrations are closely correlated with minimum relative humidity, mean temperature, and mean NOx concentration.  相似文献   

17.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

18.
Extensive research for establishing the emissions of heavy metals from coal-fired power stations is performed in the Netherlands for the past 25 years. In the Netherlands coal is fired from all over the world. This means that the emissions are established for coal of various origins. In the eighties, the emissions of installations equipped with ESPs (electrostatic precipitators) were measured. In the nineties, the influence of wet FGD (flue gas desulphurisation) on the emissions was studied. The effect of co-combustion of biomass and other secondary fuels is the main item for the last 10 years.Fifty-five elements were measured in the solid state and eight elements in the gaseous phase. It appeared that at low particulate concentration the influence of calcium containing evaporated water droplets downstream the wet FGD on the emissions of heavy metals is bigger than the composition of the coal. Also it appeared that at modern coal-fired power stations the emissions are hardly influenced by co-combustion of biomass. All the results are used for modelling, resulting in the KEMA TRACE MODEL®, by which the emissions can be predicted. The established emission factors are for most elements in good agreement with literature values for comparable modern installations.Persistence organic pollutants (POPs) that were detected in the flue gases of coal-fired power stations are polycyclic aromatic hydrocarbons (PAH) and dioxins/furans. Measurements during full coal-firing and during co-firing of biomass have indicated that these emissions are negligible.  相似文献   

19.
The visual impact of primary particles emitted from stacks is regulated according to stack opacity criteria. In-stack monitoring of the flue gas opacity allows plant operators to ensure that the plant meets U.S. Environmental Protection Agency opacity regulations. However, the emission of condensable gases such as SO3 (that hydrolyzes to H2SO4), HCl, and NH3, which may lead to particle formation after their release from the stack, makes the prediction of stack plume opacity more difficult. We present here a computer simulation model that calculates the opacity due to both primary particles emitted from the stack and secondary particles formed in the atmosphere after the release of condensable gases from the stack. A comprehensive treatment of the plume rise due to buoyancy and momentum is used to calculate the location at which the condensed water plume has evaporated (i.e., where opacity regulations apply). Conversion of H2SO4 to particulate sulfate occurs through nucleation and condensation on primary particles. A thermodynamic aerosol equilibrium model is used to calculate the amount of ammonium, chloride, and water present in the particulate phase with the condensed sulfate. The model calculates the stack plume opacity due to both primary and secondary particles. Examples of model simulations are presented for three scenarios that differ by the emission control equipment installed at the power plant: (1) electrostatic precipitators (ESP), (2) ESP and flue gas desulfurization, and (3) ESP and selective catalytic reduction. The calculated opacity is most sensitive to the primary particulate emissions. For the conditions considered here, SO3 emissions showed only a small effect, except if one assumes that most H2SO4 condenses on primary particles. Condensation of NH4Cl occurs only at high NH3 emission rates (about 25 ppm stack concentration).  相似文献   

20.
为实现二恶英快速检测,指导废物焚烧炉二恶英减排,通过检测生活垃圾焚烧炉烟气中氯苯和二恶英浓度,研究了三氯苯、四氯苯和二恶英之间的关联关系,并利用实验室自行研制的飞行时间质谱仪对烟气样品的三氯苯进行在线检测。结果表明,三氯苯与二恶英毒性当量(I-TEQ)之间存在良好关联性,相关系数(R2)可达到0.89。仪器检测信号强度与三氯苯浓度之间具有良好的线性关系,根据在线检测烟气样品中三氯苯的信号可得到三氯苯浓度,并根据关联模型计算得到二恶英毒性当量值I-TEQ,实现了对烟气样品中二恶英的快速间接测量。  相似文献   