首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
Biofiltration has been increasingly used for cleaning waste gases, mostly containing low concentrations of odorous compounds. To expand the application area of this technology, the biofiltration of higher pollutant loading rates has to be investigated. This article focuses on the biodegradation of isobutanal (IBAL) in a compost biofilter (BF) at mass loading rates between 211 and 4123 g/m3/day (30-590 ppm(v)). At mass loading rates up to 785 g/m3/day, near 100% removal efficiencies could be obtained. However, after increasing the loading rate to 1500-1900 g/m3/ day, the degradation efficiency decreased to 62-98%. In addition, a pH decrease and production of isobutanol (IBOL) and isobutyric acid (IBAC) were observed. This is the first report showing that an aldehyde can act as electron donor as well as acceptor in a BF. To study the effects of pH, compost moisture content, and electron acceptor availability on the biofiltration of IBAL, IBOL, and IBAC, additional batch and continuous experiments were performed. A pH of 5.2 reduced the IBAL degradation rate and inhibited the IBOL degradation, although adaptation of the microorganisms to low pH was observed in the BFs. IBAC was not degraded in the batch experiments. High moisture content (51%) initially had no effect on the IBOL production, although it negatively affected the IBAL elimination increasingly during a 21-day time-course experiment. In batch experiments, the reduction of IBAL to IBOL did not decrease when the amount of available electron acceptors (oxygen or nitrate) was increased. The IBAL removal efficiency at higher loading rates was limited by a combination of nutrient limitation, pH decrease, and dehydration, and the importance of each limiting factor depended on the influent concentration.  相似文献   

2.
ABSTRACT

Thermophilic biodégradation of toluene with active compost biofilters was studied. Thermophilic conditions were maintained either by daily substrate addition (semicontinuous composting) or with a heating system (batch thermophilic composting). The semicontinuous system was designed for the treatment of cool (less than approximately 35 °C) gases under thermophilic conditions, while the extended batch approach was developed for the treatment of warmer gases. When the semicontinuous system was operated at 50 °C (after a one-day start-up period) at an average inlet concentration of 5.5 g m-3, toluene was degraded at a rate ranging from 73 to 110 g C m-3 hr-1. Batch thermophilic treatment was somewhat less effective at the same inlet concentration. Semicontinuous toluene biofiltration at 60 °C was also investigated, but biodegradation rates were significantly lower than at 50 °C. In all systems, toluene biodegradation was proportional to the inlet concentration. Rates of up to 289 g C m-3 hr-1 (at an inlet concentration of 14.7 g m-3) were achieved for semicontinuous and batch operation and 251 g C m-3 hr-1 (at an inlet concentration of 18.4 g m-3) for batch thermophilic at 50 °C. Semicontinuous thermophilic operation at 60 °C showed a maximum rate of 119 g C m-3 hr-1. Active compost ther-mophilic biofiltration was found to be very effective when concentrations are high. At lower concentrations, rates were similar to those obtained with mesophilic biofiltration. Mixing, humidity, and the presence of cosubstrate were important parameters in maintaining high degradation rates. Biofiltration in the batch thermophilic mode could be useful when conventional biofiltration is ineffective due to elevated gas temperatures. Biofiltration in the semicontinuous thermophilic could reduce the biofilter size necessary for treatment of cooler gases containing high concentrations of volatile organic compounds.  相似文献   

3.
Bioprocesses, such as biofiltration, are commonly used to treat industrial effluents containing volatile organic compounds (VOCs) at low concentrations. Nevertheless, the use of biofiltration for indoor air pollution (IAP) treatment requires adjustments depending on specific indoor environments. Therefore, this study focuses on the convenience of a hybrid biological process for IAP treatment. A biofiltration reactor using a green waste compost was combined with an adsorption column filled with activated carbon (AC). This system treated a toluene-micropolluted effluent (concentration between 17 and 52 µg/m3), exhibiting concentration peaks close to 733 µg/m3 for a few hours per day. High removal efficiency was obtained despite changes in toluene inlet load (from 4.2 × 10?3 to 0.20 g/m3/hr), which proves the hybrid system’s effectiveness. In fact, during unexpected concentration changes, the efficiency of the biofilter is greatly decreased, but the adsorption column maintains the high efficiency of the entire process (removal efficiency [RE] close to 100%). Moreover, the adsorption column after biofiltration is able to deal with the problem of the emission of particles and/or microorganisms from the biofilter.
ImplicationsIndoor air pollution is nowadays recognized as a major environmental and health issue. This original study investigates the performance of a hybrid biological process combining a biofilter and an adsorption column for removal of indoor VOCs, specifically toluene.  相似文献   

4.
Abstract

Carbonyl sulfide (COS) is an odor-causing compound and hazardous air pollutant emitted frequently from wastewater treatment facilities and chemical and primary metals industries. This study examined the effectiveness of biofiltration in removing COS. Specific objectives were to compare COS removal efficiency for various biofilter media; to determine whether hydrogen sulfide (H2S), which is frequently produced along with COS under anaerobic conditions, adversely impacts COS removal; and to determine the maximum elimination capacity of COS for use in biofilter design. Three laboratory-scale polyvinyl chlo-ride biofilter columns were filled with up to 28 in. of biofilter media (aged compost, fresh compost, wood chips, or a compost/wood chip mixture). Inlet COS ranged from 5 to 46 parts per million (ppm) (0.10–9.0 g/m3fihr). Compost and the compost/wood chip mixture produced higher COS removal efficiencies than wood chips alone. The compost and compost/wood chip mixture had a shorter stabilization times compared with wood chips alone. Fresh versus aged compost did not impact COS removal efficiency. The presence of H2S did not adversely impact COS removal for the concentration ratios tested. The maximum elimination capacity is at least 9 g/m3·hr for COS with compost media.  相似文献   

5.
Abstract

The kinetic behavior of the toluene biofiltration process was investigated in this research. Toluene was used as a model compound for less water-soluble gas pollutants. The limiting factor in the overall toluene biofiltration process was determined by analyzing the effectiveness factor of the biofilm along the biofilter. Experiments were conducted in three laboratory-scale biofilters packed with mixtures of chaff/compost, D.E. (diatomaceous earth)/compost and GAC (granular activated carbon)/compost, respectively. A mathematical model previously proposed was verified in this study as being applicable to these biofilters packed with different filter materials. Both the experimental and theoretical results confirmed that the biodegradation rate along the biofilter followed the zero order, fractional order to first order kinetics as toluene concentration decreased. Moreover, at higher toluene concentration, biodegradation rate and mass flux of toluene were lower near the bottom of the biofilter due to substrate inhibition. Analysis of the effectiveness factor indicated that biofiltration of a less soluble compound such as toluene should not be operated at high gas flow rates (low gas residence times) due to the mass transfer limitation of such a system. At an approximate constant inlet toluene concentration of 0.9 g/m3, the toluene removal efficiency in these three biofilters would drop below 90% when the gas residence time decreased to 2.5, 2.5, and 2.0 min, respectively.  相似文献   

6.
Biofiltration is a method of biological treatment belonging to cleaner technologies because it does not produce secondary air pollutants, but helps to integrate natural processes in microorganisms for decomposing volatile air pollutants and solving odor problems. The birch wood biochar has been chosen as a principal material for biofilter bed medium. The experiments were conducted at the temperatures of 24, 28, and 32 °C, while the concentration of acetone, xylene, and ammonium reached 300 mg/m3 and the flow rate was 100 m3/hr. Before passing through the stage of the experimental research into the packing material inside biofilters, microorganisms were introduced. Four strains of microorganisms (including micromycetes Aspergillus versicolor BF-4 and Cladosporium herbarum 7KA, as well as yeast Exophiala sp. BF1 and bacterium Bacillus subtilis B20) were selected. At the inlet loading rate of 120 g/m3/hr, the highest elimination capacity of xylene in the biochar-based biofilter with the inoculated medium was 103 g/m3/hr, whereas that of ammonia was 102 g/m3/hr and that of acetone was 97 g/m3/hr, respectively. The maximum removal efficiency reached 86%, 85%, and 81%, respectively. The temperature condition (though characterized by some rapid changes) can hardly have a considerable influence on the biological effect (i.e., microbiological activity) of biofiltration; however, it can cause the changes in physical properties (e.g., solubility) of the investigated compounds.

Implications: The birch biochar can be successfully used in the biofiltration system for propagation of inoculated microorganisms, biodegrading acetone, xylene, and ammonia. At the inlet loading rate of 120 g/m3/hr, the highest elimination capacity of xylene was 103 g/m3/hr, that of ammonia was 102 g/m3/hr, and that of acetone was 97 g/m3/hr, respectively. The morphological structure of biochar can be affected by the aggressive air contaminants, causing the change in the medium specific surface area, which is one of the factors controlling the biofilter performance. Although biological effects in biofiltration are typically considered to be more important than physical effects, the former may be more important for compounds with high Henry’s Law coefficient values, and the biofilter design should thus provide conditions for better compound absorption.  相似文献   


7.
ABSTRACT

The 1990 Amendments to the Clean Air Act have stimulated strong interest in the use of biofiltration for the economical, engineered control of volatile organic compounds (VOCs) in effluent air streams. Trickle bed air biofilters (TBABs) are especially applicable for treating VOCs at high loadings. For long-term, stable operation of highly loaded TBABs, removal of excess accumulated bio-mass is essential. Our previous research demonstrated that suitable biomass control for TBABs was achievable by periodic backwashing of the biofilter medium. Backwashing was performed by fluidizing the pelletized biological attachment medium with warm water to about a 40% bed expansion. This paper presents an evaluation of the impact of backwashing on the performance of four such TBABs highly loaded with toluene. The inlet VOC concentrations studied were 250 and 500 ppmv toluene, and the loadings were 4.1 and 6.2 kg COD/m3 day (55 and 83 g toluene/m3 hr). Loading is defined as kg of chemical oxygen demand per cubic meter of medium per day. Performance deterioration at the higher loading was apparently due to a reduction of the specific surface of the attached biofilm resulting from the accumulation of excess biomass. For a toluene loading of 4.1 kg COD/m3 day, it was demonstrated that the long-term performance of biofilters with either inlet concentration could be maintained at over 99.9% VOC removal by employing a backwashing strategy consisting of a frequency of every other day and a duration of 1 hr.  相似文献   

8.
Abstract

The long-term stability of a biofilter loaded with waste gases containing NH3 concentrations larger than 100 ppmv was studied in a laboratory-scale compost reactor. At an empty bed residence time (τ) of 21 sec, elimination capacities of more than 300 g NH3/m3/day were obtained at elimination efficiencies up to 87%. Because of absorption and nitrification, almost 80% of the NH3-N eliminated from the waste gas could be recovered in the compost as NH4+-N or NO2 ?/NO3 ?-N. The high elimination capacities could be maintained as long as the NH4+/NOx concentration in the carrier material was less than 4 g NH4+/NOx ?-N/kg wet compost. Above this critical value, osmotic effects inhibited the nitrifying activity, and the elimination capacity for NH3 decreased. To restore the biofilter performance, a carbon source (methanol) was added to reduce NH4+/NOx ? accumulated in the compost. Results indicate that methylotrophic microorganisms did convert NH4+/NOx ? into biomass, as long as the NO3 ? content in the compost was larger than 0.1 g NO3 ?-N/kg compost. Removal efficiencies of CH3OH of more than 90% were obtained at volumetric loads up to 11,000 g CH3OH/m3/day. It is shown that addition of CH3OH is a suitable technique for regenerating the compost material from osmotic inhibition as a result of high NH3 loading. The biofilter was operated for 4 months with alternating loading of NH3 and CH3OH.  相似文献   

9.
ABSTRACT

Bioconversion of dimethylformamide (DMF) was studied using two sets of three-stages-in-series biofilters, one packed with inoculated pig manure and the other with coconut fiber compost-based media. The two media were different in carbon/nitrogen (C/N) ratio and specific area. Tests were made to compare effects of different C/N ratio and specific area on the performance of the filter and on the variation of physicochemical properties of the media for treating DMF. DMF concentration in the influent air stream was in the range of 100 to 4,500 mg/m3. The gas retention time (GRT) in the first stages of both filters was 19 to 76 sec. The volumetric loading of DMF (L) to the first stages of both filters was 3 to 97 g DMF-N/m3.h (15.6 to 506 g DMF/m3.h). Results indicated that DMF was successively hydrolyzed to ammonia and nitrified to nitrite and nitrate or incorporated into microbial cell. Inlet portions of the media subjected to high DMF or ammonia loading varied greatly in pH due to insufficient buffering capacity. The middle portions of the media subjected to moderate ammonia loading were suitable for nitrification. The coconut fiber compost media with a higher initial C/ N ratio and porosity favored the elimination of DMF. For the media, DMF-N removal efficiencies of larger than 90% were obtained with L < 50 g DMF-N/m3.h and GRT > 23 sec. The pig manure compost media with a lower initial C/N ratio favored the nitrification reaction; its maximum capacity was 8.58 g NO3 --N/m3.h.  相似文献   

10.
Abstract

This study was conducted to evaluate the performance of an innovative two-stage process, BIOCELL, that was developed to produce hydrogen (H2) and methane (CH4) from food waste on the basis of phase separation, reactor rotation mode, and sequential batch technique. The BIOCELL process consisted of four leaching-bed reactors for H2 recovery and post-treatment and a UASB reactor for CH4 recovery. The leaching-bed reactors were operated in a rotation mode with a 2-day interval between degradation stages. The sequential batch technique was useful to optimize environmental conditions during H2 fermentation. The BIOCELL process demonstrated that, at the high volatile solids (VS) loading rate of 11.9 kg/m3-day, it could remove 72.5% of VS and convert VSremoved to H2 (28.2%) and CH4 (69.9%) on a chemical oxygen demand (COD) basis in 8 days. H2 gas production rate was 3.63 m3/m3 ·day, while CH4 gas production rate was 1.75 m3/m3 ·day. The yield values of H2 and CH4 were 0.31 and 0.21 m3/kg VSadded, respectively. Moreover, the output from the post-treatment could be used as a soil amendment. The BIOCELL process proved to be stable, reliable, and effective in resource recovery as well as waste stabilization.  相似文献   

11.
A novel photocatalytic reactor for wastewater treatment was designed and constructed. The main part of the reactor was an aluminum tube in which 12 stainless steel circular baffles and four quartz tube were placed inside of the reactor like shell and tube heat exchangers. Four UV–C lamps were housed within the space of the quartz tubes. Surface of the baffles was coated with TiO2. A simple method was employed for TiO2 immobilization, while the characterization of the supported photocatalyst was based on the results obtained through performing some common analytical methods such as X-ray diffraction (XRD), scanning electron microscope (SEM), and BET. Phenol was selected as a model pollutant. A solution of a known initial concentration (20, 60, and 100 ppmv) was introduced to the reactor. The reactor also has a recycle flow to make turbulent flow inside of the reactor. The selected recycle flow rate was 7?×?10?5 m3.s?1, while the flow rate of feed was 2.53?×?10?7, 7.56?×?10?7, and 1.26?×?10?6 m3.s?1, respectively. To evaluate performance of the reactor, response surface methodology was employed. A four-factor three-level Box–Behnken design was developed to evaluate the reactor performance for degradation of phenol. Effects of phenol inlet concentration (20–100 ppmv), pH (3–9), liquid flow rate (2.53?×?10?7?1.26?×?10?6 m3.s?1), and TiO2 loading (8.8–17.6 g.m?2) were analyzed with this method. The adjusted R 2 value (0.9936) was in close agreement with that of corresponding R 2 value (0.9961). The maximum predicted degradation of phenol was 75.50 % at the optimum processing conditions (initial phenol concentration of 20 ppmv, pH?~?6.41, and flow rate of 2.53?×?10?7 m3.s?1 and catalyst loading of 17.6 g.m?2). Experimental degradation of phenol determined at the optimum conditions was 73.7 %. XRD patterns and SEM images at the optimum conditions revealed that crystal size is approximately 25 nm and TiO2 nanoparticles with visible agglomerates distribute densely and uniformly over the surface of stainless steel substrate. BET specific surface area of immobilized TiO2 was 47.2 and 45.8 m2 g?1 before and after the experiments, respectively. Reduction in TOC content, after steady state condition, showed that maximum phenol decomposition occurred at neutral condition (pH?~?6). Figure
The schematic view of the experimental set-up  相似文献   

12.
厌氧产氢ASBR对氮的脱除   总被引:2,自引:0,他引:2  
祝静  袁林江  魏勃 《环境工程学报》2014,8(4):1273-1277
在厌氧序批式人工有机污水生物产氢反应器(ASBR)中发现氮"丢失"现象,并对此产氢系统发生脱氮作用的机理和主要影响因素进行了研究。结果表明,在以葡萄糖为发酵底物的厌氧产氢系统中,微生物分别以铵和硫酸盐为电子供体和电子受体发生了硫酸盐型厌氧氨氧化;进水有机物负荷和pH主要通过影响不同种微生物的活性而影响脱氮性能,氨氮和硫酸盐的浓度直接与氮素去除率有关。在最大产氢能力为16 m3/(m3·d)、氢气体积百分比为65%的生物制氢系统中,最大脱氮效率约为64%。产氢效率与氮脱除率呈现负相关关系。研究表明,在控制条件下,可以实现高有机物废水厌氧脱除氨态氮,为生活污水直接厌氧脱氮开辟一条新途径。  相似文献   

13.
Abstract

A method to measure the in situ degradation rate of dissolved hydrocarbon contamination has been developed and applied at two locations at a field site. The method uses the rates of downward diffusion of oxygen and upward diffusion of carbon dioxide through the unsaturated zone, as calculated from vertical soil-gas concentration gradients, combined with stoichiometry to obtain two degradation rates in hydrocarbon mass per water table surface area per time. Values of 0.385 gram per m2 per day and 0.52 gram per m2 per day (based upon oxygen data) and 0.056 gram per m2 per day and 0.12 gram per m2 per day (based upon carbon dioxide data) were calculated at a field site with dissolved fuel contamination. This result of lower values from ground-air carbon dioxide concentrations is consistent with a significant fraction of the carbon dioxide produced being lost to the aqueous phase. Based upon a single-stage equilibrium phase-transfer model, gas/water volume ratios of 0.02 and 0.2 for the capillary fringe were calculated. Groundwater carbon dioxide fugacities and soil-gas carbon dioxide concentrations were used at the two locations and a third to determine whether the source of elevated soil carbon dioxide concentrations were unsaturated-zone hydrocarbon degradation or a saturated-zone process. This technique has potential applicability in setting risk-based remedial criteria and in allowing inclusion of the contribution of in situ degradation in remedial design. This can result in major remedial cost savings.  相似文献   

14.
Abstract

Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppmv), methyl ethyl ketone (12 ppmv), toluene (29 ppmv), ethylbenzene (10 ppmv), and p-xylene (10 ppmv). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m?3 hr?1 and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.  相似文献   

15.
Polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) have been monitored in air and deposition at four UK urban sites (London, Cardiff, Manchester and Stevenage) since the beginning of 1991; data from the first 2 years are presented here. Median Σ2,3,7,8-substituted PCDD/F concentrations in air were 3.2, 4.0, 3.5 and 2.6 pg/m3 respectively for London, Cardiff, Manchester and Stevenage. Median Σ2,3,7,8-substituted PCDD/F deposition fluxes were 1.5 ng/m2/day in London, 1.4 ng/m2/day in Cardiff and Manchester and 0.79 ng/m2/day in Stevenage. Seasonal variations in the PCDD/F concentrations were observed at all sites for both air and deposition, with concentrations/fluxes generally elevated during the winter.  相似文献   

16.
Abstract

This study aimed to develop a biofilter packed only with fern chips for the removal of airborne propylene glycol monomethyl ether acetate (PGMEA). Fern chips could avoid the shortcomings of traditional media, such as compaction, drying, and breakdown, which lead to the performance failure of the biofilters. In addition, the fern chip medium has the following merits: (1) simplicity in composition; (2) low pressure drop for gas ?ow (<20 mmH2O?m-1); (3) simple in humidification, nutrient addition, pH control, and metabolite removal; (4) economical (US$174–385?m-3), and (5) low weight (wet basis around 290 kg?m-3). A two-stage down?ow biofilter (2.18 m in height and 0.4×0.4 m in cross-sectional area) was constructed for the performance test. Both stages were packed with fern chips of 0.30 m in height and 0.40×0.40 m in cross-section. Results indicate that with operation conditions of media moisture content controlled in the range of 50–74%, media pH of 6.5–8.3, empty bed retention time (EBRT) of 0.27–0.4 min, in?uent PGMEA concentrations of 100–750 mg?m-3, volu-metric organic loading of <170 ?m-3 ?hr-1, and nutrition rates of Urea-nitrogen 66 g?m-3 ?day-3, potassium dihydrogen phosphate (KH2PO4)-phosphorus 13.3 g ?m-3 ?day-3, and milk powder 1.00 g?m-3?day-1, the fern-chip-packed biofilter could achieve an overall PGMEA removal efficacy of around 94%. Instant milk powder or liquid milk was essential to the good and stable performance of the biofilter for PGMEA removal.  相似文献   

17.
This study compares the performances of fern and plastic chips as packing media for the biofiltration of a styrene-laden waste gas stream emitted in a plant for the manufacture of plastic door plates. Fern chips (with a specific surface area of 1090 m2 m?3) and plastic chips (with a specific surface area of 610 m2 m?3) were packed into a pilot-scale biotrickling filter with a total medium volume of 50 L for the performance test. Field waste gas with styrene concentrations in the range of 161–2390 mg Am?3 at 28–30 °C) was introduced to the bed and a fixed empty-bed retention time (EBRT) of 21 sec, a volumetric gas flow rate of 8.57 m3 hr?1, and superficial gas velocity of 53.6 m hr?1 were maintained throughout the experimental period. Nutrients containing metal salts, nitrogen, phosphorus, and milk were supplemented to the filters for maintaining the microbial activities. Results reveal that the biotrickling filter developed in this study had the highest styrene monomer (SM) elimination capacities (170 g m?3 hr?1 for fern-chip packing and 300 g m?3 hr?1 for plastic-chip packing) among those cited in the literature. The plastic medium is a favorable substitute for endangered fern chips. The thermal-setting nature of plastic chips limits their recycle and reuse as raw materials, and the study provides an opportunity for the utilization of the materials.

Implications: Biotreatment of contaminants in air streams offers an inexpensive and efficient alternative to conventional technologies. Biofiltration has a great potential for the degradation of gas-borne styrene and total hydrocarbon (THC) removal efficiency of around 80%. The objective of this research was to compare the performances of fern chips and a kind of plastic chips as packing media for biofiltration of the styrene-laden waste gas stream emitted from cutting operations of stripes of premixed unsaturated polyester (UP) and styrene paste before hot-pressing operations for making plastic door plates. From a practical point of view, the plastic medium can be a good substitute medium for fern chips, which has been declared as a protected plant. This study provides an experimentally verified model for the design and operation of such biotreatment systems.  相似文献   

18.
The degradation of ciprofloxacin was studied in aqueous solutions by using a continuous flow homogeneous photo-Fenton process under simulated solar light. The effect of different operating conditions on the degradation of ciprofloxacin was investigated by changing the hydrogen peroxide (0–2.50 mM) and iron(II) sulphate (0–10 mg Fe L?1) concentrations, as well as the pH (2.8–10), irradiance (0–750 W m?2) and residence time (0.13–3.4 min) of the process. As expected, the highest catalytic activity in steady state conditions was achieved at acidic pH (2.8), namely 85 % of ciprofloxacin conversion, when maintaining the other variables constant (i.e. 2.0 mg L?1 of iron(II), 2.50 mM of hydrogen peroxide, 1.8 min of residence time and 500 W m?2 of irradiance). Additionally, magnetite magnetic nanoparticles (ca. 20 nm of average particle size) were synthesized, characterized and tested as a possible catalyst for this reaction. In this case, the highest catalytic activity was achieved at natural pH, namely a 55 % average conversion of ciprofloxacin in 1.8 min of residence time and under 500 W m?2. Some of the photocatalytic activity was attributed to Fe2+ leaching from the magnetic nanoparticles to the solution.  相似文献   

19.
The degradation of bifenthrin (BF) and chlorpyrifos (CP), either together or individually, by a bacterial strain (CB2) isolated from activated sludge was investigated. Strain CB2 was identified as belonging to genus Pseudomonas based on the morphological, physiological, and biochemical characteristics and a homological analysis of the 16S rDNA sequence. Strain CB2 has the potential to degrade BF and CP, either individually or in a mixture. The optimum conditions for mixture degradation were as follows: OD600nm = 0.5; incubation temperature = 30°C; pH = 7.0; BF-CP mixture (10 mg L?1 of each). Under these optimal conditions, the degradation rate constants (and half-lives) were 0.4308 d?1 (1.61 d) and 0.3377 d?1 (2.05 d) for individual BF and CP samples, respectively, and 0.3463 d?1 (2.00 d) and 0.2931 d?1 (2.36 d) for the BF-CP mixture. Major metabolites of BF and CP were 2-methyl-3-biphenylyl methanol and 3,5,6-trichloro-2-pyridinol, respectively. No metabolite bioaccumulation was observed. The ability of CB2 to efficiently degrade BF and CP, particularly in a mixture, may be useful in bioremediation efforts.  相似文献   

20.
A microscale zero-valent iron (mZVI)-based in situ reactive zone is a promising technology for contaminated groundwater remediation. Estimation of mZVI aging behavior after its injection into the subsurface is essential for efficiency and longevity assessments. In this study, batch tests were conducted to investigate the effect of initial pH on mZVI aging dynamics, as well as the formation and evolution of aging products over 112 days. Results indicated that mZVI aging accelerated with decreasing initial pH. Corrosion rates of mZVI particles under pH 6.0 and 7.5 were approximately two orders of magnitude higher than those observed at pH 9.0. The morphological, structural, and compositional evolution of mZVI particles in three systems (pH = 6.0, 7.5, and 9.0) were investigated using scanning electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. In acidic and neutral solutions, a thick passivation layer with loosely and unevenly distributed aging precipitates was observed, and Fe3O4 was the final aging precipitate. Nevertheless, in alkaline solutions, minute aging precipitates were detected on the mZVI surface at 112 day. Characterization results suggested that mZVI was oxidized via the Fe0–Fe(OH)2–Fe3O4 route. These findings shed new light on mZVI aging mechanisms, particularly its physicochemical characteristics and the structural evolution of mZVI in field-scale groundwater remediation applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏