首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO2) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO2 and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three consecutive weeks. OVM concentrations were corrected for ambient pressure to account for higher elevation. Precise results (< 5% relative standard deviation, RSD) were found for NO2 measurements from collocated Ogawa samplers. Reproducibility was lower from duplicate OVMs for BTEX (benzene, toluene, ethylbenzene, and xylene isomers) VOCs (> or = 77% RSD for 2-day samples) with better precision for longer sampling periods. Comparison of Ogawa NO2 samplers with chemiluminescence measurements averaged over the same time period suggested potential calibration problems with the chemiluminescence analyzer. For BTEX species, generally good agreement was obtained between OVMs and automated-gas chromatograph (auto-GC) measurements. The OVMs successfully tracked increasing levels of VOCs recorded by the auto-GCs. However, except for toluene, OVM BTEX measurements generally exceeded their continuous counterparts with a mean bias of 5-10%. Although interpretation of the study results was limited due to small sample sizes, diffusion barrier influences caused by shelters that housed OVMs and differences in sampling heights between OVMs and auto-GC inlet may explain the overestimation.  相似文献   

2.
The Mechanistic Indicators of Childhood Asthma (MICA) study in Detroit, Michigan introduced a participant-based approach to reduce the resource burden associated with collection of indoor and outdoor residential air sampling data. A subset of participants designated as MICA-Air conducted indoor and outdoor residential sampling of nitrogen dioxide (NO2), volatile organic compounds (VOCs), and polycyclic aromatic hydrocarbons (PAHs). This participant-based methodology was subsequently adapted for use in the Vanguard phase of the U.S. National Children’s Study. The current paper examines residential indoor and outdoor concentrations of these pollutant species among health study participants in Detroit, Michigan.Pollutants measured under MICA-Air agreed well with other studies and continuous monitoring data collected in Detroit. For example, NO2 and BTEX concentrations reported for other Detroit area monitoring were generally within 10–15% of indoor and outdoor concentrations measured in MICA-Air households. Outdoor NO2 concentrations were typically higher than indoor NO2 concentration among MICA-Air homes, with a median indoor/outdoor (I/O) ratio of 0.6 in homes that were not impacted by environmental tobacco smoke (ETS) during air sampling. Indoor concentrations generally exceeded outdoor concentrations for VOC and PAH species measured among non-ETS homes in the study. I/O ratios for BTEX species (benzene, toluene, ethylbenzene, and m/p- and o-xylene) ranged from 1.2 for benzene to 3.1 for toluene. Outdoor NO2 concentrations were approximately 4.5 ppb higher on weekdays versus weekends. As expected, I/O ratios pollutants were generally higher for homes impacted by ETS.These findings suggest that participant-based air sampling can provide a cost-effective alternative to technician-based approaches for assessing indoor and outdoor residential air pollution in community health studies. We also introduced a technique for estimating daily concentrations at each home by weighting 2- and 7-day integrated concentrations using continuous measurements from regulatory monitoring sites. This approach may be applied to estimate short-term daily or hourly pollutant concentrations in future health studies.  相似文献   

3.
Volatile organic compounds (VOCs) such as benzene, toluene, ethylbenzene, and xylene (BTEX) along with inorganic gases such as sulfur dioxide (SO2), nitrogen dioxide (NO2), and ozone (O3) levels were found in the atmosphere of the Kemerburgaz region where environmental issues became a major concern due to nearby incineration plant and waste disposal facility in Istanbul. Ten sampling locations were selected considering possible sources in the study area. The sampling areas were classified as suburban, industrial, rural, and background regions. Sampling campaigns were carried out for four-week periods from March 2011 to August 2012 in all locations. Elevated concentrations of BTEX around roads and the industrial locations indicated that vehicle exhaust and industrial activities were the main sources of these pollutants in the region. Concentrations of NO2 were also high around roads. A much more uniform distribution was observed for SO2 during sampling periods. However higher levels were observed at suburban locations due to the use of coal for local heating especially during winter. Ozone concentrations were low at the industrial locations and roadsides, but high in suburban and rural locations downwind from the sources. The results of these organic and inorganic gases meet the national limit values. Furthermore, a lifetime risk assessment methodology was used to evaluate the potential adverse health effects of BTEX. The mean cancer risk level for benzene was estimated to be 7.71E-07 that is lower than assigned acceptable risk level of 1.0E-04. Toluene, ethylbenzene, and xylenes were lower than the specified level of 1.0 with respect to mean non-carcinogenic risks. The findings reveal that determined BTEX emissions do not pose a health threat to residents in the studied region.  相似文献   

4.
Abstract

The Houston-Galveston metropolitan area has a relatively high density of point and mobile sources of air toxics, and determining and understanding the relationship between emissions and ambient air concentrations of air toxics is important for evaluating potential impacts on public health and formulating effective regulatory policies to control this impact, both in this region and elsewhere. However, conventional ambient air monitoring approaches are limited with regard to expense, siting limitations, and representative sampling necessary for adequate exposure assessment. The overall goal of this multiphase study is to evaluate the use of simple passive air samplers to determine temporal and spatial variability of the ambient air concentrations of selected volatile organic compounds (VOCs) in urban areas. Phase 1 of this study, reported here, was a field evaluation of 3M organic vapor monitors (OVMs) involving limited comparisons with commonly used active sampling methods, an assessment of sampler precision, a determination of optimal sampling duration, and an investigation of the utility of a simple modification of the commercial sampler. The results indicated that a sampling duration of 72 hr exhibited generally low bias relative to automated continuous gas chromatography measurements, good overall precision, and an acceptable number of measurements above detection limits. The modified sampler showed good correlation with the commercial sampler, with higher sampling rates, although lower than expected.  相似文献   

5.
Monitoring of nitrogen dioxide (NO2) by passive sampling on the Danish island Funen (Fyn) show that the concentration of nitrogen dioxide is low (2–20 ppb). The level of NO2 in rural and suburban areas is governed by imported airpollution, and elevated NO2 concentrations due to local traffic are of limited importance. These results are supported by diffusion denuder measurements of nitric acid (HNO3) and particulate nitrate. Measurements of NO2 with chemiluminescence and diffusive passive sampling showed good agreement between the methods. The special mounting device for the diffusive samplers used in this work seem to have reduced the turbulence at the open end of the tube. The product from the reaction between nitrogen dioxide and triethanolamine was investigated and tentatively identified as triethanolamine N-oxide, which is in accordance with the observed 1 : 1 stoechiometry in the conversion of NO2 to nitrite ions.  相似文献   

6.
7.
Measurement of ambient NO2 concentrations using diffusion tube samplers is widespread in many countries, particularly in the UK. A National Network of NO2 diffusion tube samplers has been operational at over 1200 sites in the UK for over 5 years. Some previous studies have indicated that NO2 diffusion tube samplers may overestimate NO2 concentrations by up to 30%, whereas others have shown an underestimation. Hence, the UK Department of Environment, Transport and the Regions commissioned this large-scale validation study. In this study diffusion tubes were exposed at 17 urban background monitoring sites equipped with chemiluminescent NO2 monitors within the UK Automatic Urban Monitoring Network. Over a one year period, diffusion tubes were exposed for 2- and 4-week periods, blacked out or clear and sheltered (from the wind) or unsheltered, in order to investigate the effect of a number of possible variables. The results of the study show that overall average NO2 concentrations calculated from diffusion tube measurements are likely to be within 10% of chemiluminescent measurement data. The uncertainty on this average difference is ±24–38% for individual diffusion tube measurements, but reduces to ±10–18% for annual averages. Differences due to the exposure period and exposure procedure were found, but these were not large.  相似文献   

8.
There is a requirement to verify the performance of sorbent-based passive or active samplers and to extend their use, where possible, to monitor volatile organic compounds (VOCs) that are known to be photochemical ozone pre-cursors or are relevant to the activities of the petrochemical industry. We report measurements of the 14-day diffusive uptake rates for the VOCs: i-butane (2-methyl propane), n-butane, i-pentane (2-methyl butane), n-pentane, n-hexane, benzene, toluene, and m-xylene (at environmental level concentrations) for industry standard axial samplers (Perkin–Elmer-type samplers) containing the sorbents Carbopack-X, -Z, -B or Tenax-TA. We also present data on back-diffusion, blank levels, and storage for the above sorbents, and describe the simultaneous use of the sorbent Carbopack-X for pumped sampling of certain VOCs. The results were obtained by dosing samplers in a controlled atmosphere test facility (CATFAC) operating under well-defined conditions of concentration, nominal temperature of 20 °C, wind speed of 0.5 m s?1, and relative humidities of 0% and 80%. Field measurements were also obtained to provide supplementary data to support the laboratory study. Results are compared to existing published data, where these are available.  相似文献   

9.
A detailed comparative trial of passive diffusion tubes (PDT) for measurement of NO2 in urban air has been undertaken in Edinburgh, UK. Acrylic, foil-wrapped and quartz tubes were exposed in parallel for 1-week and 4-week periods at three urban sites equipped with continuous analysers for NO, NOx and O3. Standard acrylic PDTs significantly overestimated NO2 concentrations relative to chemiluminescence analysers, by an average of 27% over all sites for 1-week exposures. No significant difference was observed between standard and foil-wrapped acrylic tubes (both UV blocking). The mean ratio between quartz (UV transmitting) tubes and chemiluminescence analysers was 1.06. Quartz PDT data suggest a tendency for in situ photolysis to offset (but in a non-quantifiable way) the effect of chemical overestimation. The 4-week exposures yielded systematically lower NO2 concentration than average NO2 from four sequential 1-week exposures over the same period. The reduction in the apparent NO2 sampling rate with time mostlikely arises from in situ photolysis of trapped NO2. Hourly NO2, NO and O3 data for 20 1-week exposures were used as input to a numerical model of diffusion tube operation incorporating chemical reaction between co-diffusing NO and O3 within the tube. The mean calculated overestimation of 22% for NO2 from the PDT model simulations is close to the average difference between acrylic PDT and analyser NO2 concentrations (24% for the same exposure periods), showing that within-tube chemistry can account for observed discrepancies in NO2 measurement between the two techniques. Overestimation by PDT generally increased as average NO2/NOx ratios decreased. Accurate quantitative correction of PDT measurements is not possible. Nevertheless, PDT NO2 concentrations were correlated with both analyser NO2 and NOx suggesting that acrylic PDTs retain a qualitative measure of NO2 and NOx variation at a particular urban location.  相似文献   

10.
Abstract

The purpose of this study was to derive a land-use regression model to estimate on a geographical basis ambient concentrations of nitrogen dioxide (NO2) in Montréal, Quebec, Canada. These estimates of concentrations of NO2 will be subsequently used to assess exposure in epidemiologic studies on the health effects of traffic-related air pollution. In May 2003, NO2 was measured for 14 consecutive days at 67 sites across the city using Ogawa passive diffusion samplers. Concentrations ranged from 4.9 to 21.2 ppb (median 11.8 ppb). Linear regression analysis was used to assess the association between logarithmic concentrations of NO2 and land-use variables derived using the ESRI Arc 8 geographic information system. In univariate analyses, NO2 was negatively associated with the area of open space and positively associated with traffic count on nearest highway, the length of highways within any radius from 100 to 750 m, the length of major roads within 750 m, and population density within 2000 m. Industrial land-use and the length of minor roads showed no association with NO2. In multiple regression analyses, distance from the nearest highway, traffic count on the nearest highway, length of highways and major roads within 100 m, and population density showed significant associations with NO2; the best-fitting regression model had a R2 of 0.54. These analyses confirm the value of land-use regression modeling to assign exposures in large-scale epidemiologic studies.  相似文献   

11.
Passive diffusion tubes are recognised as a cost-effective sampling method for characterising the spatial variability, as well as the seasonal and annual trends, of NO2 concentrations in urban areas. In addition, NOX and O3 passive diffusion tubes have been developed and deployed in urban and rural areas. Despite their many advantages (e.g. low operational and analysis cost, small size and no need for power supply), they have certain limitations mainly related to their accuracy and precision. In particular, the absorbent solution used, the length of the exposure period, the exact location and use of protective devices, and other environmental conditions (e.g. wind, ambient temperature and relative humidity) may have a significant impact on the performance of passive diffusion tubes. The aim of this study is to evaluate the performance of co-located NO2, NOX and O3 diffusion tubes in an urban environment.A one-year passive sampling campaign was carried out in Birmingham (UK) for this purpose. NO2, NOX and O3 diffusion tubes (including triplicate sets of each) were co-located at one urban background and two roadside permanent air quality monitoring stations equipped with standard gas analysers. In addition, meteorological data, such as wind speed and direction, ambient temperature and relative humidity, were obtained during the same period of time. A thorough QA/QC procedure, including storage and laboratory blanks was followed throughout the campaign. The analysis of results showed a very good agreement of NO2 passive samplers with co-located chemiluminescence analysers, but substantial underestimations of total NOX levels by the diffusion tubes. The O3 diffusion sampler appeared to marginally overestimate the automatic UV analyser results, especially during warm weather periods.  相似文献   

12.
Concentrations of traffic-related air pollution can be highly variable at the local scale and can have substantial seasonal variability. This study was designed to provide estimates of intra-urban concentrations of ambient nitrogen dioxide (NO2) in Montreal, Canada, that would be used subsequently in health studies of chronic diseases and long-term exposures to traffic-related air pollution. We measured concentrations of NO2 at 133 locations in Montreal with passive diffusion samplers in three seasons during 2005 and 2006. We then used land use regression, a proven statistical prediction method for describing spatial patterns of air pollution, to develop separate estimates of spatial variability across the city by regressing NO2 against available land-use variables in each of these three periods. We also developed a “pooled” model across these sampling periods to provide an estimate of an annual average. Our modelling strategy was to develop a predictive model that maximized the model R2. This strategy is different from other strategies whose goal is to identify causal relationships between predictors and concentrations of NO2.Observed concentrations of NO2 ranged from 2.6 ppb to 31.5 ppb, with mean values of 12.6 ppb in December 2005, 14.0 ppb in May 2006, and 8.9 ppb in August 2006. The greatest variability was observed during May. Concentrations of NO2 were highest downtown and near major highways, and they were lowest in the western part of the city. Our pooled model explained approximately 80% of the variability in concentrations of NO2. Although there were differences in concentrations of NO2 between the three sampling periods, we found that the spatial variability did not vary significantly across the three sampling periods and that the pooled model was representative of mean annual spatial patterns.  相似文献   

13.
The Houston-Galveston metropolitan area has a relatively high density of point and mobile sources of air toxics, and determining and understanding the relationship between emissions and ambient air concentrations of air toxics is important for evaluating potential impacts on public health and formulating effective regulatory policies to control this impact, both in this region and elsewhere. However, conventional ambient air monitoring approaches are limited with regard to expense, siting limitations, and representative sampling necessary for adequate exposure assessment. The overall goal of this multiphase study is to evaluate the use of simple passive air samplers to determine temporal and spatial variability of the ambient air concentrations of selected volatile organic compounds (VOCs) in urban areas. Phase 1 of this study, reported here, was a field evaluation of 3M organic vapor monitors (OVMs) involving limited comparisons with commonly used active sampling methods, an assessment of sampler precision, a determination of optimal sampling duration, and an investigation of the utility of a simple modification of the commercial sampler. The results indicated that a sampling duration of 72 hr exhibited generally low bias relative to automated continuous gas chromatography measurements, good overall precision, and an acceptable number of measurements above detection limits. The modified sampler showed good correlation with the commercial sampler, with higher sampling rates, although lower than expected.  相似文献   

14.
Select volatile organic compounds (VOCs) in ambient air were measured at four fenceline sites at a petroleum refinery in Whiting, IN, using modified EPA Method 325 A/B with passive tubes and EPA Compendium Method TO-15 with canister samplers. One-week, time-integrated samplers were deployed for 8 weeks with tubes and canister samplers deployed in duplicate. Good precision was obtained from the duplicate tubes (<7%) and duplicate canisters (≤10%) for BTEX, perchloroethylene, and styrene. The tubes yielded statistically significantly higher concentrations than canisters for benzene, toluene, ethylbenzene, and m,p-xylene. However, all differences were estimated to be <0.1 ppbv. No concentration differences among the four Whiting sites were found for any of the VOCs.

Implications: Recently enacted EPA Methods 325A/B use passive-diffusive tube samplers to measure benzene at refinery fenceline locations. This pilot study presents VOC data applying a modified version of EPA Method 325 A/B and its comparison to EPA Compendium Method TO-15 canister samplers at four refinery fenceline sites. The findings from this study provide additional confidence in application of the tube method at refineries to ascertain VOC source influence since tube and canister samplers were comparable and good precision was obtained from duplicate sampling for both methods. No overall difference in these reported VOC concentrations was found between Whiting sites for tubes or canisters.  相似文献   


15.
A network of 10 stations, with passive sampling for VOCs (including benzene), NO2, and SO2, over 2-week periods, grab sampling for CO, and 48-h pumped sampling for PM10, was set up to make an air quality survey for 12 months around Aberdeen Harbour. Benzene, CO, SO2 and PM10 were always well below the AQS target values. However, NO2 frequently showed a pronounced gradient across the harbour reaching its highest concentrations at the city end, indicating that the road traffic was the principal source of the pollution. This was backed up by the predominance of aromatics in the VOCs in the city centre, derived from petrol engined vehicles, compared to the predominance of alkanes and alkenes around the docks, derived from diesel engined heavy trucks and possibly ships. Black carbon on the PM10 filters also showed a gradient with highest levels in the city centre. It is proposed that for such surveys in future, NO2 and black carbon would be the two most informative parameters.This emissions inventory has shown first, that trucks contribute very little to the total, and second, that the ro-ro ferries are the major contributors as they burn light fuel oil while the oil platform supply vessels burn low-sulphur marine gas oil with around 0.1% S. When the whole picture of the emissions from the city is considered, the emissions from the harbour constitute only a small part.  相似文献   

16.
ABSTRACT

The air quality in five Finnish ice arenas with different volumes, ventilation systems, and resurfacer power sources (propane, gasoline, electric) was monitored during a usual training evening and a standardized, simulated ice hockey game. The measurements included continuous recording of carbon monoxide (CO), nitric oxide (NO), and nitrogen dioxide (NO2) concentrations, and sampling and analysis of volatile organic compounds (VOCs). Emissions from the ice resurfacers with combustion engines caused indoor air quality problems in all ice arenas. The highest 1-hour average CO and NO2 concentrations ranged from 20 to 33 mg/m3 (17 to 29 ppm) and 270 to 7440 µg/m3 (0.14 to 3.96 ppm), respectively. The 3-hour total VOC concentrations ranged from 150 to 1200 µg/m3. The highest CO and VOC levels were measured in the arena in which a gasoline-fueled resurfacer was used. The highest NO2 levels were measured in small ice arenas with propane-fueled ice resurfacers and insufficient ventilation.

In these arenas, the indoor NO2 levels were about 100 times the levels measured in ambient outdoor air, and the highest 1-hour concentrations were about 20 times the national and World Health Organization (WHO) health-based air quality guidelines. The air quality was fully acceptable only in the arena with an electric resurfacer. The present study showed that the air quality problems of indoor ice arenas may vary with the fuel type of resurfacer and the volume and ventilation of arena building. It also confirmed that there are severe air quality problems in Finnish ice arenas similar to those previously described in North America.  相似文献   

17.
The Desert Research Institute conducted an on-road mobile source emission study at a traffic tunnel in Van Nuys, California, in August 2010 to measure fleet-averaged, fuel-based emission factors. The study also included remote sensing device (RSD) measurements by the University of Denver of 13,000 vehicles near the tunnel. The tunnel and RSD fleet-averaged emission factors were compared in blind fashion with the corresponding modeled factors calculated by ENVIRON International Corporation using U.S. Environmental Protection Agency's (EPA's) MOVES2010a (Motor Vehicle Emissions Simulator) and MOBILE6.2 mobile source emission models, and California Air Resources Board's (CARB's) EMFAC2007 (EMission FACtors) emission model. With some exceptions, the fleet-averaged tunnel, RSD, and modeled carbon monoxide (CO) and oxide of nitrogen (NOx) emission factors were in reasonable agreement (±25%). The nonmethane hydrocarbon (NMHC) emission factors (specifically the running evaporative emissions) predicted by MOVES were insensitive to ambient temperature as compared with the tunnel measurements and the MOBILE- and EMFAC-predicted emission factors, resulting in underestimation of the measured NMHC/NOx ratios at higher ambient temperatures. Although predicted NMHC/NOx ratios are in good agreement with the measured ratios during cooler sampling periods, the measured NMHC/NOx ratios are 3.1, 1.7, and 1.4 times higher than those predicted by the MOVES, MOBILE, and EMFAC models, respectively, during high-temperature periods. Although the MOVES NOx emission factors were generally higher than the measured factors, most differences were not significant considering the variations in the modeled factors using alternative vehicle operating cycles to represent the driving conditions in the tunnel. The three models predicted large differences in NOx and particle emissions and in the relative contributions of diesel and gasoline vehicles to total NOx and particulate carbon (TC) emissions in the tunnel.

Implications: Although advances have been made to mobile source emission models over the past two decades, the evidence that mobile source emissions of carbon monoxide and hydrocarbons in urban areas were underestimated by as much as a factor of 2–3 in past inventories underscores the need for on-going verification of emission inventories. Results suggest that there is an overall increase in motor vehicle NMHC emissions on hot days that is not fully accounted for by the emission models. Hot temperatures and concomitant higher ratios of NMHC emissions relative to NOx both contribute to more rapid and efficient formation of ozone. Also, the ability of EPA's MOVES model to simulate varying vehicle operating modes places increased importance on the choice of operating modes to evaluate project-level emissions.  相似文献   

18.
Abstract

The objectives of this study were: (1) to quantify the errors associated with saturation air quality monitoring in estimating the long-term (i.e., annual and 5 yr) mean at a given site from four 2-week measurements, once per season; and (2) to develop a sampling strategy to guide the deployment of mobile air quality facilities for characterizing intraurban gradients of air pollutants, that is, to determine how often a given location should be visited to obtain relatively accurate estimates of the mean air pollutant concentrations. Computer simulations were conducted by randomly sampling ambient monitoring data collected in six Canadian cities at a variety of settings (e.g., population-based sites, near-roadway sites). The 5-yr (1998–2002) dataset consisted of hourly measurements of nitric oxide (NO), nitrogen dioxide (NO2), oxides of nitrogen (NOx), sulfur dioxide (SO2), coarse particulate matter (PM10), fine particulate matter (PM2.5), and CO. The strategy of randomly selecting one 2-week measurement per season to determine the annual or long-term average concentration yields estimates within 30% of the true value 95% of the time for NO2, PM10 and NOx. Larger errors, up to 50%, are expected for NO, SO2, PM2.5, and CO. Combining concentrations from 85 random 1-hr visits per season provides annual and 5-yr average estimates within 30% of the true value with good confidence. Overall, the magnitude of error in the estimates was strongly correlated with the variability of the pollutant. A better estimation can be expected for pollutants known to be less temporally variable and/or over geographic areas where concentrations are less variable. By using multiple sites located in different settings, the relationships determined for estimation error versus number of measurement periods used to determine long-term average are expected to realistically portray the true distribution. Thus, the results should be a good indication of the potential errors one could expect in a variety of different cities, particularly in more northern latitudes.  相似文献   

19.
A pilot study was conducted in application of the U.S. Environmental Protection Agency (EPA) Methods 325A/B variant for monitoring volatile organic compounds (VOCs) near two oil and natural gas (ONG) production well pads in the Texas Barnett Shale formation and Colorado Denver–Julesburg Basin (DJB), along with a traffic-dominated site in downtown Denver, CO. As indicated in the EPA method, VOC concentrations were measured for 14-day sampling periods using passive-diffusive tube samplers with Carbopack X sorbent at fenceline perimeter and other locations. VOCs were significantly higher at the DJB well pad versus the Barnett well pad and were likely due to higher production levels at the DJB well pad during the study. Benzene and toluene were significantly higher at the DJB well pad versus downtown Denver. Except for perchloroethylene, VOCs measured at passive sampler locations (PSs) along the perimeter of the Barnett well pad were significantly higher than PSs farther away. At the DJB well pad, most VOC concentrations, except perchloroethylene, were significantly higher prior to operational changes than after these changes were made. Though limited, the results suggest passive samplers are precise (duplicate precision usually ≤10%) and that they can be useful to assess spatial gradients and operational conditions at well pad locations over time-integrated periods.

Implications: Recently enacted EPA Methods 325A/B use passive-diffusive tube samplers to measure benzene at multiple fenceline locations at petrochemical refineries. This pilot study presents initial data demonstrating the utility of Methods 325A/B for monitoring at ONG facilities. Measurements revealed elevated concentrations reflective of production levels and spatial gradients of VOCs relative to source proximity at the Barnett well pad, as well as operational changes at the DJB well pad. Though limited, these findings indicate that Methods 325A/B can be useful in application to characterize VOCs at well pad boundaries.  相似文献   


20.
ABSTRACT

This paper presents a study on ground-level ozone (O3), nitrogen oxides (NOx = NO + NO2) concentrations, and their variabilities in the ambient air of three sites of a tropical archipelago that is moderately urbanized. Statistical analysis was performed on a quite complete (>80%) set of 5 years of measurements (2008–2012). There are few studies on those pollutants and their seasonal behavior in the Caribbean area, where pollution level and cities configuration are different from megacities. Analyses are focused on pollutant variations at the scale of the day, the week, and the seasons, using hourly data. The observations show that NOx concentrations are more elevated during the wet season, whereas O3 concentrations are higher in the dry season. Amplitudes of ozone cycles are strongly influenced by meteorological conditions (temperature, global radiation, and wind speed) and prevailing levels of NOx. An ozone weekend effect is detected with the highest amplitude in the city, where anthropogenic activity is the lowest during the weekend. Due to the nature and the origin of pollutants, NOx shows higher variability than O3 in the time series. Our results evince the need for continuous measurements of volatile organic compounds (VOCs) in order to better quantify their contribution in O3 formation in an insular context where numerous natural sources have been identified.

Implications: Statistical analyses of observed NOx and O3 concentrations for 5 years for a typical low industrialized site of the Caribbean area have been done. Air quality for those components is correct based on the standards of the World Health Orgaization, pollutant source spatial distributions, and level of industrialization. Observations show the same patterns as in megacities but also a strong impact of weather conditions and road traffic. Behaviors of O3 cannot be fully explained without VOCs monitoring. Localization and type of AQS should be reconsidered to improve the accuracy of concentrations of the pollutant and better understand their behaviors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号