首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The design and the construction of an actual 8.7-m3 pilot/full-scale biotrickling filter for waste air treatment is described and compared with a previous conceptual scale-up of a laboratory reactor. The reactor construction costs are detailed and show that about one-half of the total reactor costs ($97,000 out of $178,000) was for personnel and engineering time, whereas approximately 20% was for monitoring and control equipment. A detailed treatment cost analysis demonstrated that, for an empty bed contact time of 90 sec, the overall treatment costs (including capital charges) were as low as $8.7/1000 m3air in the case where a nonchlorinated volatile organic compound (VOC) was treated, and $14/1000 m3air for chlorinated compounds such as CH2Cl2. Comparison of these costs with conventional air pollution control techniques demonstrates excellent perspectives for more field applications of biotrickling filters. As the specific costs of building and operating biotrickling filter reactors decrease with increasing size of the reactor, the cost benefit of biotrickling filtration is expected to increase for full technical-scale bioreactors.  相似文献   

2.
ABSTRACT

This paper presents results obtained from a performance study on the biotreatment of 1,3-butadiene in an air stream using a reactor that consisted of a two-stage, in-series biotrickling filter connected with a three-stage, in-series biofilter. Slags and pig manure-based media were used as packing materials for the biotrickling filter and the biofilter, respectively. Experimental results indicated that, for the biotrickling filter portion, the butadiene elimination capacities were below 5 g/m3/hr for loadings of less than 25 g/m3/hr, and the butadiene removal efficiency was only around 17%. For the biofilter portion, the elimination capacities ranged from 10 to 107 g/m3/hr for loadings of less than 148 g/m3/hr. The average butadiene removal efficiency was 75–84% for superficial gas velocities of 53–142 m/hr and a loading range of 10–120 g/m3/hr. The elimination capacity approached a maximum of 108 g/m3/hr for a loading of 150 g/m3/hr. The elimination rates of butadiene in both the biotrickling filter and biofilter were mass-transfer controlled for influent butadiene concentrations below about 600 ppm for superficial gas velocities of 29–142 m/hr. The elimination capacity was significantly higher in the biofilter than in the biotrickling filter. This discrepancy may be attributed to the higher mass-transfer coefficient and gas-solid interfacial area offered for transferring the gaseous butadiene in the biofilter.  相似文献   

3.
ABSTRACT

Xylene is the main component of many volatile industrial pollution sources, and the use of biotechnology to remove volatile organic compounds (VOCs) has become a growing trend. In this study, a biotrickling filter for gaseous xylene treatment was developed using activated sludge as raw material to study the biodegradation process of xylene. Reaction conditions were optimized, and long-term operation was performed. The optimal pH was 7.0, gas-liquid ratio was 15:1 (v/v), and temperature was 25 °C. High-throughput sequencing technique was carried out to analyze microbial communities in the top, middle, and bottom layers of the reactor. Characteristics of microbial diversity were elucidated, and microbial functions were predicted. The result showed that the removal efficiency (RE) was stable at 86%–91%, the maximum elimination capacity (EC) was 303.61 g·m?3·hr?1, residence time was 33.75 sec, and the initial inlet xylene concentration was 3000 mg·m?3, which was the highest known degradation concentration reported. Kinetic analysis of the xylene degradation indicated that it was a very high-efficiency-activity bioprocess. The rmax was 1059.8 g·m?3·hr?1, and Ks value was 4.78 g·m?3 in stationary phase. In addition, microbial community structures in the bottom and top layers were significantly different: Pseudomonas was the dominant genus in the bottom layer, whereas Sphingobium was dominant in the top layer. The results showed that intermediate metabolites of xylene could affect the distribution of community structure. Pseudomonas sp. can adapt to high concentration xylene–contaminated environments.

Implications: We combined domesticated active sludge and reinforced microbial agent on biotrickling filter. This system performed continuously under a reduced residence time at 33.75 sec and high elimination capacity at 303.61 g·m?3·hr?1 in the biotrickling reactor for about 260 days. In this case, predomestication combined with reinforcing of microorganisms was very important to obtaining high-efficiency results. Analysis of microbial diversity and functional prediction indicated a gradient distribution along with the concentration of xylene. This implied a rational design of microbial reagent and optimizing the inoculation of different sites of reactor could reduce the preparation period of the technology.  相似文献   

4.
Because of the characteristics of low operating cost and convenient operation, the biotrickling filter is extensively researched and used to treat low concentration waste gas contaminated by volatile organic compounds (VOCs) and other odors. In this paper, two laboratory-scale biotrickling filters were constructed and toluene was selected as the sole carbon source, and the effects of different waste-gas flow configuration patterns on the purification capacity and the microbial community functional diversity of biotrickling filters were evaluated. The results indicated that the flow-directional-switching (FDS) biotrickling filter had better purification performance, and the maximum elimination capacity reached 480 g·m?3·hr?1, which was 17.1% higher than conventional unidirectional-flow (UF) biotrickling filter. Comparing the purification capacities of different sections in two biotrickling filters, the maximum toluene elimination capacity of section III in FDS system could reach 542 g·m?3·hr?1, which was 2.8 times as great as that in UF system, which resulted from the difference of elimination capacity in two systems. By analyzing the metabolic activity of two systems by community-level physiological profiling (CLPP) with Biolog (Biolog Inc., Hayward, CA) ECO-plate technique, metabolic activity in three sections of FDS system was higher than that of UF system. The metabolic activity was the highest in section III of FDS system and 46.8% higher than that of UF system. Shannon index and McIntosh index of section III in FDS system were 6.2% and 31.5% higher, respectively, than those of UF system.

Implications: The flow-directional-switching (FDS) biotrickling filter had a better purification performance than unidirectional-flow (UF) biotrickling filter at high inlet loadings, because FDS produced a more uniform distribution of biomass and microbial metabolic capacity along the length of the packed bed without diminishing activity and removal capacity in the inlet section.  相似文献   

5.
ABSTRACT

A biotrickling filter with blast-furnace slag packings (sizes = 20-40 mm and specific surface area = 120 m2/m3) was utilized to treat NO in an air stream. The operational stability, as well as the effects of gas empty-bed retention time (EBRT) and nutrient addition on the removal ability of NO, were tested. Approximately six weeks were required for the development of a biofilm for NO degradation, and a two-week organic carbon deficiency resulted in the detachment of biofilms from the packing surfaces. A steady removal rate of 80% was attained at specified influent NO concentrations of 892 to 1237 ppm and an EBRT of 118 sec. The effluent NO concentration diminished exponentially with enlarging EBRT, with influent NO concentrations of 203-898 ppm, and EBRTs of 25 to 118 sec. Nutrient addition is essential for efficient removal of the influent NO. Mass ratios of C: P: N = 7: 1: 30 and NaHCO3: NO-N = 6.3 could be used for practical applications.  相似文献   

6.
研究以甲苯为驯导物的生物滴滤塔挂膜启动阶段净化性能的变化。实验结果表明,通过控制pH和湿度得到了真菌滴滤系统,启动周期为14 d,比细菌滴滤塔长7 d;在进化性能方面,在入口负荷、浓度为80 g/(m3.h)、3 000 mg/m3的条件下获得了稳定在98%以上的去除效率;对比2种填料对启动阶段的影响,在较低负荷下(≤80 g/(m3.h))对系统的启动时间和去除效率没有显著影响。  相似文献   

7.
ABSTRACT

This paper reports results of studies using a biotrickling filter with blast-furnace slag packings (sizes = 2–4 cm and specific surface area = 120 m2/m3) for treatment of ethylether in air stream. Effects of volumetric loading, superficial gas velocity, empty bed gas retention time, recirculation liquid flow rate, and biofilm renewal on the ethylether removal efficiency and elimination capacity were tested. Results indicate that ethylether removal efficiencies of more than 95% were obtained with an empty bed retention time (EBRT) of 113 sec and loadings of lower than 70 g/m3/hr. At an EBRT of 57 sec, removal efficiencies of more than 90% could only be obtained with loadings of lower than 35 g/m3/hr. The maximum elimination capacities were 71 and 45 g/m3/hr for EBRT = 113 and 57 sec, respectively. The maximum ethylether elimination capacities were 71 and 96 g/m3/hr, respectively, before and after the renewal at EBRT = 113 sec. With an EBRT of 113 sec and a loading of lower than 38 g/m3/hr, the removal efficiency was nearly independent of the superficial liquid recirculation velocity in the range of 3.6 to 9.6 m3/m2/hr. From data regression, simplified mass-transfer limited, and reaction- and mass-transfer limited models correlating the contaminant concentration and the packing height were proposed and verified. The former model is applicable for cases of low influent contaminant concentrations or loadings, and the latter is applicable for cases of higher ones. Finally, CO2 conversion efficiencies of approximately 90% for the influent ethylether were obtained. The value is comparable to data reported from other related studies.  相似文献   

8.
Abstract

Four different biofilter packing materials (two porous ceramics, perlite, and open pore polyurethane foam) were compared for the removal of toluene vapors. The focus was on evaluating performance at relatively short gas retention time (13.5 and 27 sec). The reactors were initially operated as biotrickling filters with continuous feeding and trickling of a nutrient solution. After significant plugging of the biotrickling filter beds with biomass was observed, the operation mode was switched to biofiltration with only periodic supply of mineral nutrients. This resulted in stable conditions, which allowed detailed investigations over >6 months. The reactor packed with cattle bone Porcelite (CBP), a ceramic material containing some macronutrients and micronutrients, exhibited the highest performance. The critical load (i.e., load at which 95% removal occurred) was 29 g m?3 hr?1 at a gas retention time of 13.5 sec and 66 g m?3 hr?1 at a gas retention time of 27 sec. After the long-term experiment, the packing materials were taken from the reactors and examined. The reactors were divided into three sections, top, middle, and bottom, to determine whether spatial differentiation of biomass occurred. The assays included a double-staining technique to count total and live microorganisms and determination of moisture, protein, and dry weight contents. Microbial community analysis was also conducted by denaturing gradient gel electrophoresis. The results showed that most reactors had a significant fraction of inactive biomass. Comparatively, the CBP biofilter held significantly higher densities of active biomass, which may be the reason for the higher toluene removal performance. The analyses suggest that favorable material properties and the nutrients slowly released by the CBP provided better environmental conditions for the process culture.  相似文献   

9.
Twenty-four congeners of polychlorinated biphenyls (PCBs) were measured in 83 air samples and 20 elastic sealants samples of apartments with PCB-containing sealants. In addition, PCBs were measured in 21 air samples from reference apartments located in an uncontaminated section of the same estate. The PCBtot levels in the air of the contaminated section were 168-3843 ng m−3 (mean: 1030 ng m−3), while the mean levels in the reference apartments were 6.03 ng m−3. The sum of the 24 measured PCB congeners in sealants from the contaminated section was 187-221 680 mg kg−1. Principal component analysis revealed four groups among the sealant samples with different congener compositions, only two of which were clearly similar to known PCB mixtures, while two were not. Significant correlations and intercorrelations were observed between the lower chlorinated congeners in air and sealant, e.g. for PCB 28air and 28seal (p = 0.04) and for PCB 28air and 52air, 52seal. However, no correlation was observed between the lower chlorinated congeners and the sums of PCB (∑PCB6 or ∑PCB24) or the higher chlorinated congeners. Analysis of air concentrations in relation to questionnaire data indicated that the indoor air levels could be reduced by increased cleaning and airing frequencies.  相似文献   

10.
Cost data were analyzed from thirty steam power plant units utilizing electrostatic precipitators with or without mechanical centrifugal collectors. Operational, maintenance, and total costs for the years 1969, 1970, and 1971 were expressed in 1972 dollars as $/cfm-yr and $/cfm-yr-efficiency. The latter parameter is a new one which normalizes the cost of air cleaning by accounting for the amount of particulate matter collected. Large differences in the costs of air cleaning were found between plants and even between units operating in the same plant. Maintenance costs appeared to be the main contributor to large total cost differences, but improved, more specific accounting procedures are required to focus more closely on the reasons for cost differences.  相似文献   

11.
ABSTRACT

This study utilized a biotrickling filter with blast-furnace slag packings (sizes = 20-40 mm; specific surface area = 120 m2/m3) to treat toluene in an air stream. Also studied were the effects of volumetric loading (L), nutrient addition, and superficial gas velocity (Ug) or gas retention time on toluene elimination capacity. Experimental results indicate that, for a test period of 121 days, with no excess biomass removal, toluene removal efficiencies of over 90% were obtained with Ug < 80 m/hr and L < 30 g/m3.hr. For a test period of 49 days, with Ug < 80 m/hr and L increased from 1.2 to 81 g/m3.hr, the absence of nutrient supplementation did not limit the toluene elimination capacity. Nutrients stored in the biofilm could adequately support the microbial activity for the toluene elimination. According to data regression, a simplified mass-transfer model is proposed, which correlates the contaminant concentration with the packing height or gas empty bed retention time. As verified, the model proposed herein can be applied to cases involving low influent contaminant concentrations or loadings to the extent that none or only a trace amount of the contaminant can be found in the recirculation liquid. Although small media with larger specific surface areas can achieve a better mass transfer, the problems of frequent backwashing and relatively greater gas resistance in using this type of media probably outweigh the advantages, particularly for full-scale systems that would not be watched as closely as laboratory test systems.  相似文献   

12.
全区108座污水处理厂建设规模、工艺、投资和运行成本统计表明,广西城镇污水处理厂以小型污水处理厂为主,处理工艺多采用氧化沟、A2/O、SBR及其变种工艺;5~10万m3/d规模污水处理单位建设投资以氧化沟、A2/O、SBR及其变种工艺较省,2~5万m3/d规模以氧化沟、MSBR工艺较省,2 m3/d以下规模以硅藻土、人工湿地和人工快渗工艺较为经济;2~10万m3/d规模污水处理厂各工艺运行成本多介于0.3~0.4元/m3,2万m3/d以下规模人工快渗和人工湿地工艺的运行费用介于0.2~0.3元/m3。不同规模、不同工艺、不同排放标准污水处理厂的投资建设、运行成本和出水水质各异,因此,污水处理厂应因地制宜选择适宜工艺技术、规模及排放标准,有效提高设施运行负荷率和污染物的去除率。  相似文献   

13.
《Chemosphere》1986,15(5):607-617
A method for the quantitative determination of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) in ambient air is described in detail. High-volume sampling of 1000 m3 air using a glass fiber filter and polyurethane foam as collection media allows to detect femtogram/m3 amounts, when negative ion chemical ionization mass spectrometry is used as detection method.  相似文献   

14.
Abstract

A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-μm particles ranged from 1.5 hr?1 during operation of an in-duct, 5-in. pleated media filter to 7.2 hr?1 for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr?1 when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 μm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr?1 under baseline conditions, 0.5 hr?1 during operation of three portable ionic air cleaners, 1 hr?1 for an in-duct 1-in. media filter, 2.4 hr?1 for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr?1 for an in-duct 5-in. media filter, 4.7 hr?1 during operation of five portable HEPA filters, 6.1 hr?1 for a conventional in-duct electronic air cleaner, and 7.5 hr?1 for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.  相似文献   

15.
Three pilot-scale, horizontal-flow biofilm reactors (HFBRs 1–3) were used to treat methane (CH4)-contaminated air to assess the potential of this technology to manage emissions from agricultural activities, waste and wastewater treatment facilities, and landfills. The study was conducted over two phases (Phase 1, lasting 90 days and Phase 2, lasting 45 days). The reactors were operated at 10 °C (typical of ambient air and wastewater temperatures in northern Europe), and were simultaneously dosed with CH4-contaminated air and a synthetic wastewater (SWW). The influent loading rates to the reactors were 8.6 g CH4/m3/hr (4.3 g CH4/m2 TPSA/hr; where TPSA is top plan surface area). Despite the low operating temperatures, an overall average removal of 4.63 g CH4/m3/day was observed during Phase 2. The maximum removal efficiency (RE) for the trial was 88%. Potential (maximum) rates of methane oxidation were measured and indicated that biofilm samples taken from various regions in the HFBRs had mostly equal CH4 removal potential. In situ activity rates were dependent on which part of the reactor samples were obtained. The results indicate the potential of the HFBR, a simple and robust technology, to biologically treat CH4 emissions.

Implications: The results of this study indicate that the HFBR technology could be effectively applied to the reduction of greenhouse gas emissions from wastewater treatment plants and agricultural facilities at lower temperatures common to northern Europe. This could reduce the carbon footprint of waste treatment and agricultural livestock facilities. Activity tests indicate that methanotrophic communities can be supported at these temperatures. Furthermore, these data can lead to improved reactor design and optimization by allowing conditions to be engineered to allow for improved removal rates, particularly at lower temperatures. The technology is simple to construct and operate, and with some optimization of the liquid phase to improve mass transfer, the HFBR represents a viable, cost-effective solution for these emissions.  相似文献   

16.
ABSTRACT

The benefits and costs of past nitrogen dioxide (NO2) control policies were calculated for Tokyo, Japan, using environmental, economic, political, demographic, and medical data from 1973 to 1994. The benefits of NO2 control were estimated as medical expenses and lost work time due to hypothetical no-control air concentrations of NO2. Direct costs were calculated as annualized capital expenditures and 1 year's operating costs for regulated industries plus governmental agency expenses. The major findings were as follows:

(1) Using Tokyo's average medical cost of pollution-related illness, the best net estimate of the avoided medical costs due to incidence of phlegm and sputum in adults was 730 billion yen ($6.08 billion; 1 U.S. dollar = 120 yen).

(2) The best net estimate of the avoided medical costs due to incidence of lower respiratory illness in children was 93 billion yen ($775 million).

(3) Using Tokyo's average duration of pollution-related illness and average wages, the best net estimate of the avoided costs of lost wages in workers was 760 billion yen ($6.33 billion).

(4) The best net estimate of the avoided costs of lost wages in mothers caring for their sick children was 100 billion yen ($833 million).

(5) Using Tokyo-specific data, the best net costs were estimated as 280 billion yen ($2.33 billion).

(6) Using human health and productivity benefits, and annualized capital cost and operating cost estimates, the best net benefits-to-costs ratio was 6:1 (upper limit 44:1; lower limit 0.3:1). Benefit calculations were sensitive to assumptions of mobile source emissions and certain health impacts that were not included. Cost calculations were highly dependent on assumptions of flue gas volume and fuel use. For comparative purposes, we identified other studies for air pollution-related illness. Assumptions that formed the basis for most of the inputs in the present study, such as duration of illness, medical treatment costs, per person illness in children, and lost wages for working mothers, were similar to those recommended in the literature. Lost wages in sick workers and per capita illness incidence in adults were higher than numbers reported elsewhere. Further advances in cost-benefit analysis (CBA) procedures to evaluate the economic effectiveness of NO2 controls in Tokyo are recommended to estimate impacts and values for additional human health benefits, ecosystem health and productivity effects, and nonliving system effects, as well as benefits of ancillary reductions in other pollutants. The present study suggests that Tokyo's past NO2 control policies in total were economically quite effective.  相似文献   

17.
Abstract

An activated sludge aeration tank (40 × 40 × 300 cm, width × length × height) with a set of 2-mm orifice air spargers was used to treat gas-borne volatile organic compounds (VOCs; toluene, p-xylene, and dichloromethane) in air streams. The effects of liquid depth (Z), aeration intensity (G/A), the overall mass-transfer rate of oxygen in clean water (K L a O2 ), the Henry’s law constant of the tested VOC (H), and the influent gaseous VOC concentration (C 0) on the efficiency of removal of VOCs were examined and compared with a literature-cited model. Results show that the measured VOC removal efficiencies and those predicted by the model were comparable at a G/A of 3.75–11.25 m3/m2·hr and C 0 of ~1000–6000 mg/m3. Experimental data also indicated that the designed gas treatment reactor with K L a O2 = 5–15 hr?1 could achieve >85% removal of VOCs with H = 0.24–0.25 at an aerated liquid depth of 1 m and >95% removal of dichloromethane with H = 0.13 at a 1-m liquid depth.  相似文献   

18.
Abstract

A 0.75-m3 pilot-scale biotrickling filter was run for over 1 yr in a Spanish furniture company to evaluate its performance in the removal of volatile organic compounds (VOCs) contained in the emission of two different paint spray booths. The first one was an open front booth used to manually paint furniture, and the second focus was an automatically operated closed booth operated to paint pieces of furniture. In both cases, the VOC emissions were very irregular, with rapid and extreme fluctuations. The pilot plant was operated at an empty bed residence time (EBRT) ranging from 10 to 40 sec, and good removal efficiencies of VOCs were usually obtained. When a buffering activated carbon prefllter was installed, the system performance was improved considerably, so a much better compliance with legal constraints was reached. After different shutdowns in the factory, the period to recover the previous performance of the biotrickling reactor was minimal. A weekend dehydration strategy was developed and implemented to control the pressure drop associated with excessive biomass accumulation.  相似文献   

19.
ABSTRACT

The main goal of this study was to evaluate the magnitude of outdoor exposure to fine particulate matter (PM10) potentially experienced by the population of metropolitan Mexico City. With the use of a geographic information system (GIS), spatially resolved PM10 distributions were generated and linked to the local population. The PM10 concentration exceeded the 24-hr air quality standard of 150 μg/m3 on 16% of the days, and the annual air quality standard of 50 μg/m3 was exceeded by almost twice its value in some places. The basic methodology described in this paper integrates spatial demographic and air quality databases, allowing the evaluation of various air pollution reduction scenarios. Achieving the annual air quality standard would represent a reduction in the annual arithmetic average concentration of 14 μg/m3 for the typical inhabitant. Human exposure to particulate matter (PM) has been associated with mortality and morbidity in Mexico City; reducing the concentration levels of this pollutant would represent a reduction in mortality and morbidity and the associated cost of such impacts. This methodology is critical to assessing the potential benefits of the current initiative to improve air quality implemented by the Environmental Metropolitan Commission of Mexico City.  相似文献   

20.
Biological air filtration for reduction of emissions of volatile sulfur compounds (e.g., hydrogen sulfide, methanethiol and dimethyl sulfide) from livestock production facilities is challenged by poor partitioning of these compounds into the aqueous biofilm or filter trickling water. In this study, Henry’s law constants of reduced volatile sulfur compounds were measured for deionized water, biotrickling filter liquids (from the first and second stages of a two-stage biotrickling filter), and NaCl solutions by a dynamic method using Proton-Transfer-Reaction Mass Spectrometry (PTR-MS) at a temperature range of 3–45 °C. NaCl solutions were used to estimate salting-out constants up to an ionic strength of 0.7 M in order to evaluate the effect of ionic strength on partitioning between air and biofilter liquids. Thermodynamic parameters (enthalpy and entropy of phase exchange) were obtained from the measured partition coefficients as a function of temperature. The results show that the partition coefficients of organic sulfur compounds in the biotrickling filter liquids were generally very close to the corresponding partition coefficients in deionized water. Based on the estimated ionic strength of biofilter liquids, it is assessed that salting-out effects are of no importance for these compounds. For H2S, a higher enthalpy of air–liquid partitioning was observed for 2nd stage filter liquid, but not for 1st stage filter liquid. In general, the results show that co-solute effects for sulfur compounds can be neglected in numerical biofilter models and that the uptake of volatile sulfur compounds in biotrickling filter liquids cannot be increased by decreasing ionic strength.  相似文献   